Loading...
HomeMy WebLinkAbout3274 GREY HAWK CT; ; AS050204; Permit10/31 /24, 3:40 PM AS050204 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS050204 327 4 GREY HAWK Job Address: Status: ISSUED CT Permit Type: SPRINK Applied 10/5/2005 Parcel No: 2210150200 Approved: 11/22/2005 Lot#: 0 Reference No.: Issued: 11/22/2005 PC#: Inspector: Project Title: BLDGS. Q,R,S FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: LIFEGUARD FIRE PROTECTION STE F 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 about:blank 0 Owner: PALOMAR FORUM ASSOCIATES LP C/O DAVIS PARTNERS LLC 1420 BRISTOL ST N #100 NEWPORT BEACH CA Total($) 1,150 1 /1 LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: GREYHA WK BUSINESS PARK Date: October 3, 2005 Location: 3274 GREYHA WK CT. Building: R-S System No. _,.-=--'----------------------ROOF Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: LCH Drawing No. 3 OF 3 Construction: [8J Combustible O Non-Combustible Ceiling Height _2;;;..;5;_-..;..0 ___ _ Ft. SYSTEM DESIGN ~ NFPA 13: LJ Light Hazard Ordinary Hazard Group U 1 LJ 2 LJ 3 125.1 Extra Hazard 0 NFPA231 0 NFPA231C: Figure: Curve: D Other (Specify) □Specific Ruling Made By Date Area of Sprinkler Operation 3000 S)'.stem T:yne Density .45 C8J Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinkler 100 S.F. MAX. S11rinkler or Nozzle Hose Allowance GPM: Inside 100 Make TYCO Model ELO231-B Hose Allowance GPM: Outside 400 Size ¾ K-factor: 11.2 Rack Sprinkler Allowance NIA Temnerature Rating 286DEG. CALCULATION SUMMARY GPM Required 1649.19 PSI Required 54.51 At Base of Riser -------------'-'--------" C" Factor Used: Overhead 120 Under ound 150 WATER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date& Time 8-3-05 I 1 :50 PM Rated Capacity Capacity Static PSI 122 At PSI Elevation Residual PSI 116 Elevation GPMFlowing 1500 Well Elevation 0 Proof Flow GPM Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD FIRE DEPT. rrn-II .. I y STOR Ar!L' Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized %Rack Rack D SingleRow D Conventional Pallet 0 Automatic Storage D Encapsulated D Double Row D Slave Pallet 0 Solid Shelving D Non-Encapsulated D Multiple Row D Open Flue S11acing In Inches Clearance From To11 of Storage to Ceiling Longitudinal Transverse Ft. In. Horizontal Barriers Provided 250 240 230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 • GREYHAWK BLOG Q-R-S ROOF .45/3000 • V • ~ V I/ ./ ,~~ 17 ([5Y'" I./ ... l V 02so 500 v . -750 1000 1250 1500 System Demand .. Sprinkler Demand 90.66 PSI Additional Flows Hose at Source Total Demand 96.18 PSI @ 1549.19 GPM 500.00 GPM 0.00 GPM @ 2049.19 GPM Hose• 1750 Water Flow (GPM) Sigma Dynamics Corporation 7700 Supply/ Demand Graph ' Margin Pressure 4.00 PSI Flow 422.95 GPM ' ~ 1' 'Bi I 2000 2250 Water Supply .. Static 109.80 PSI Residual 104.40 PSI Elevation 0.00 PSI @ 1500.00 GPM ~ ~ N 1.8!5 2500 SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 1 GREYHAWK BLDG Q-R-S ROOF .45/3000 FLOW TEST RESULTS Water Supply STATIC 109.80 PSI RESIDUAL 104.40 PSI @ 1500.00 GPM CITY PRESSURE AVAILABLE AT 2049.2 GPM 100.18 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE ---------------- 100 59.93 45.00 11.20 28.63 101 50.82 45.00 11.20 20.59 102 50.79 45.00 11.20 20.56 103 50.70 45.00 11. 20 20.49 104 50.67 45.00 11.20 20.47 105 59.16 45.00 11.20 27.90 106 48.70 45.00 11.20 18.91 107 48.66 45.00 11.20 18.88 108 48.58 45.00 11.20 18.81 109 48.56 45.00 11.20 18.80 110 58.80 45.00 11.20 27.56 111 47.15 45.00 11.20 17.73 112 47.12 45.00 11. 20 17.70 113 47.04 45.00 11.20 17.64 114 47.02 45.00 11. 20 17.62 115 58.70 45.00 11.20 27.47 116 46.12 45.00 11.20 16.96 117 46.09 45.00 11.20 16.93 118 46.01 45.00 11.20 16.87 119 45.98 45.00 11. 20 16.86 121 45.51 45.00 11. 20 16.51 122 45.47 45.00 11.20 16.49 123 45.39 45.00 11.20 16.43 124 45.37 45.00 11. 20 16.41 126 45.21 45.00 11.20 16.30 127 45.18 45.00 11.20 16.27 128 45.10 45.00 11. 20 16.22 129 45.08 45.00 11. 20 16.20 131 45.13 45.00 11. 20 16.24 SUBMI'ITAL SERIAL NO:4144HY1 GREYHAWK BLDG Q-R-S ROOF .45/3000 SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR -------- 132 45.10 45.00 11.20 133 45.02 45.00 11.20 134 45.00 45.00 11.20 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 12 OUTFLOWS AT 22 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 12 TO 20 PRESSURE -------- 16.22 16.16 16.14 1549.19 GPM 400.00 GPM 100.00 GPM 2049.19 GPM 96.18 PSI 0.00 PSI 19.26 FPS 10-03-2005 PAGE 2 SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 3 GREYHAWK BLDG Q-R-S ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 129 134 2.703 L 10.00 C=l20 PT 16.14 (134) Q 45.00 F=0 F 0.00 PE 0.00 BN T 10.00 0.0058 PF 0.06 124 129DQ 45.08 2.703 L 10.00 C=l20 PT 16.20 (129) Q 90.08 F=0 F 0.00 PE 0.00 BN T 10.00 0.0210 PF 0.21 119 124DQ 45.37 2.703 L 10.00 C=l20 PT 16.41 (124) Q 135.45 F=0 F 0.00 PE 0.00 EN T 10.00 0.0446 PF 0.45 114 119DQ 45.98 2.703 L 10.00 C=120 PT 16.86 (119) Q 181.44 F=0 F 0.00 PE 0.00 BN T 10.00 0.0766 PF 0.77 109 114DQ 47.02 2.703 L 10.00 C=l20 PT 17.63 (114) Q 228.46 F=0 F 0.00 PE 0.00 BN T 10.00 0.1173 PF 1.17 104 109DQ 48.56 2.703 L 10.00 C=l20 PT 18.80 (109) Q 277.01 F=0 F 0.00 PE 0.00 BN T 10.00 0.1676 PF 1.68 44 104DQ 50.67 2.703 L 42.75 C=120 PT 20.48 (104) Q 327.69 F=T F 16.70 PE 0.00 BN T 59.45 0.2286 PF 13.59 34 44 2.703 L 0.83 C=l20 PT 34.07 44) Q 327.69 F=T F 16.70 PE 0.36 NR T 17.53 0.2286 PF 4.01 PT 38.44 34) ------------------128 133 2.703 L 10.00 C=120 PT 16.16 (133) Q 45.02 F=0 F 0.00 PE 0.00 BN T 10.00 0.0058 PF 0.06 123 128DQ 45.10 2.703 L 10.00 C=120 PT 16.22 (128) Q 90.13 F=0 F 0.00 PE 0.00 BN T 10.00 0.0210 PF 0.21 118 123DQ 45.39 2.703 L 10.00 C=120 PT 16.43 (123) Q 135.52 F=0 F 0.00 PE 0.00 BN T 10.00 0.0446 PF 0.45 113 118DQ 46.01 2.703 L 10.00 C=120 PT 16.88 ( 118) Q 181.53 F=0 F 0.00 PE 0.00 BN T 10.00 0.0767 PF 0.77 SUBMITIAL SERIAL NO:4144HY1 10-03-2005 PAGE 4 GREYHAWK BLDG Q-R-S ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 108 113DQ 47.04 2.703 L 10.00 C=120 PT 17.65 (113) Q 228.57 F=0 F 0.00 PE 0.00 BN T 10.00 0.1174 PF 1.17 103 108DQ 48.58 2.703 L 10.00 C=120 PT 18.82 (108) Q 277.15 F=0 F 0.00 PE 0.00 BN T 10.00 0.1677 PF 1.68 43 103DQ 50.70 2.703 L 42.75 C=120 PT 20.50 (103) Q 327.85 F=T F 16.70 PE 0.00 BN T 59.45 0.2289 PF 13.61 33 43 2.703 L 0.83 C=120 PT 34.11 43) Q 327.85 F=T F 16.70 PE 0.36 NR T 17.53 0.2289 PF 4.01 PT 38.48 33) ------------------127 132 2.703 L 10.00 C=120 PT 16.22 (132) Q 45.10 F=0 F 0.00 PE 0.00 BN T 10.00 0.0058 PF 0.06 122 127DQ 45.18 2.703 L 10.00 C=120 PT 16.28 ( 127) Q 90.28 F=0 F 0.00 PE 0.00 BN T 10.00 0.0211 PF 0.21 117 122DQ 45.47 2.703 L 10.00 C=120 PT 16.49 (122) Q 135.76 F=0 F 0.00 PE 0.00 BN T 10.00 0.0448 PF 0.45 112 117DQ 46.09 2.703 L 10.00 C=l20 PT 16.94 (117) Q 181.85 F=0 F 0.00 PE 0.00 BN T 10.00 0.0769 PF 0.77 107 112DQ 47.12 2.703 L 10.00 C=l20 PT 17.71 (112) Q 228.97 F=0 F 0.00 PE 0.00 BN T 10.00 0.1178 PF 1.18 102 107DQ 48.66 2.703 L 10.00 C=120 PT 18.89 (107) Q 277.63 F=0 F 0.00 PE 0.00 BN T 10.00 0.1683 PF 1. 68 42 102DQ 50.79 2.703 L 42.75 C=120 PT 20.57 (102) Q 328.42 F=T F 16.70 PE 0.00 BN T 59.45 0.2296 PF 13.65 32 42 2.703 L 0.83 C=120 PT 34.22 42) Q 328.42 F=T F 16.70 PE 0.36 NR T 17.53 0.2296 PF 4.02 PT 38.60 32) SUBMITIAL SERIAL NO:4144HY1 10-03-2005 PAGE 5 GREYHAWK BLDG Q-R-S ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ------------------ 126 131 2.703 L 10.00 C=120 PT 16.24 ( 131) Q 45.13 F=0 F 0.00 PE 0.00 BN T 10.00 0.0058 PF 0.06 121 126DQ 45.21 2.703 L 10.00 C=120 PT 16.30 ( 126) Q 90.35 F=0 F 0.00 PE 0.00 BN T 10.00 0.0211 PF 0.21 116 121DQ 45.51 2.703 L 10.00 C=120 PT 16.51 (121) Q 135.85 F=0 F 0.00 PE 0.00 BN T 10.00 0.0448 PF 0.45 111 116DQ 46.12 2.703 L 10.00 C=120 PT 16.96 (116) Q 181. 97 F=0 F 0.00 PE 0.00 BN T 10.00 0.0770 PF 0.77 106 lllDQ 47.15 2.703 L 10.00 C=120 PT 17.73 ( 111) Q 229.13 F=0 F 0.00 PE 0.00 BN T 10.00 0.1180 PF 1.18 101 106DQ 48.70 2.703 L 10.00 C=120 PT 18.91 (106) Q 277.82 F=0 F 0.00 PE 0.00 BN T 10.00 0.1685 PF 1. 69 41 101DQ 50.82 2.703 L 42.75 C=120 PT 20.60 (101) Q 328.65 F=T F 16.70 PE 0.00 BN T 59.45 0.2299 PF 13.67 31 41 2.703 L 0.83 C=120 PT 34.27 41) Q 328.65 F=T F 16.70 PE 0.36 NR T 17.53 0.2299 PF 4.03 PT 38.66 31) ------------------110 115 2.703 L 10.00 C=120 PT 27.47 (115) Q 58.70 F=0 F 0.00 PE 0.00 BN T 10.00 0.0095 PF 0.09 105 ll0DQ 58.80 2.703 L 10.00 C=120 PT 27.56 (110) Q 117.50 F=0 F 0.00 PE 0.00 BN T 10.00 0.0343 PF 0.34 100 105DQ 59.16 2.703 L 10.00 C=120 PT 27.90 (105) Q 176.66 F=0 F 0.00 PE 0.00 BN T 10.00 0.0729 PF 0.73 40 l00DQ 59.93 2.703 L 42.75 C=120 PT 28.63 ( 100) Q 236.59 F=T F 16.70 PE 0.00 BN T 59.45 0.1252 PF 7.44 SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 6 GREYHAWK BLDG Q-R-S ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 30 40 2.703 L 0.83 C=l20 PT 36.07 40) Q 236.59 F=T F 16.70 PE 0.36 NR T 17.53 0.1252 PF 2.19 PT 38.62 30) ------------------ 9 12 7.758 L 80.00 C=l50 PT 90.79 12) Q 1166.96 F=GV,T F 58.94 PE 0.00 LU T 138.94 0.0093 PF 1. 29 8 9DQ -984.57 7.758 L 259.00 C=l50 PT 92.08 9) Q 182.38 F=2GV, 2EE F 39.26 PE 0.00 LU T 298.26 0.0003 PF 0.09 11 8DQ -68.96 7.758 L 145.00 C=l50 PT 92.17 8) Q 113.42 F=GV,T F 58.94 PE 0.00 LU T 203.94 0.0001 PF 0.02 4 11 7.758 L 120.00 C=150 PT 92.19 11) Q 113.42 F=T,GV,EE F 72.53 PE 0.00 LU T 192.53 0.0001 PF 0.02 PT 92.21 4) ------------------ 3 12 7.758 L 215.00 C=150 PT 90.79 12) Q 882.23 F=T,GV F 58.94 PE 0.00 LU T 273.94 0.0056 PF 1.53 PT 92.32 ( 3) ------------------10 9 7.758 L 160.00 C=l50 PT 92.09 9) Q 984.57 F=GV F 6.04 PE 0.00 LU T 166.04 0.0068 PF 1.13 1 10 7.758 L 326.00 C=150 PT 93.22 10) Q 984.57 F=2EE,4GV,T F 104.24 PE 0.00 LU T 430.24 0.0068 PF 2.93 PT 96.15 1) ------------------7 8 7.758 L 382.00 Cs:150 PT 92.18 8) Q 68.96 F=T,GV F 58.94 PE 0.00 LU T 440.94 0.0000 PF 0.00 6 7 7.758 L 40.00 C=l50 PT 92.18 7) Q 68.96 F=0 F 0.00 PE 0.00 LU T 40.00 0.0000 PF 0.00 5 6 7.758 L 157.00 C=l50 PT 92.18 ( 6) Q 68.96 F=GV,2EE F 33.22 PE 0.00 LU T 190.22 0.0000 PF 0.00 SUBMITI'AL SERIAL N0:4144HY1 10-03-2005 PAGE 7 GREYHAWK BLDG Q-R-S ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 4 5 7.758 L 320.00 C=150 PT 92.18 5) Q 68.96 F=GV F 6.04 PE 0.00 LU T 326.04 0.0000 PF 0.00 3 4DQ 113.42 7.758 L 266.00 C=150 PT 92.18 4) Q 182.38 F=2GV,EE F 25.67 PE 0.00 LU T 291.67 0.0003 PF 0.09 2 3DQ 882.23 7.758 L 75.00 C=150 PT 92.27 3) Q 1064.62 F=GV F 6.04 PE 0.00 LU T 81.04 0.0079 PF 0.64 1 2 7.758 L 314.00 C=150 PT 92.91 2) Q 1064.62 F=2GV,T,2EE F 92.16 PE 0.00 LU T 406.16 0.0079 PF 3.21 PT 96.12 1) ------------------ 33 34 6.357 L 10.00 C=120 PT 38.43 34) Q 327.69 F=0 F 0.00 PE 0.00 FMl T 10.00 0.0036 PF 0.04 32 33DQ 327.85 6.357 L 10.00 C=120 PT 38.47 ( 33) Q 655.53 F=0 F 0.00 PE 0.00 FMl T 10.00 0.0128 PF 0.13 24 32DQ 328.42 6.357 L 4.00 C=120 PT 38.60 32) Q 983.95 F=0 F 0.00 PE 0.00 FMl T 4.00 0.0272 PF 0.11 PT 38.71 24) ------------------31 30 6.357 L 10.00 C=120 PT 38.63 30) Q 236.59 F=0 F 0.00 PE 0.00 FMl T 10.00 0.0019 PF 0.02 24 31DQ 328.65 6.357 L 6.00 C=120 PT 38.65 ( 31) Q 565.23 F=0 F 0.00 PE 0.00 FMl T 6.00 0.0097 PF 0.06 23 24DQ 983.95 6.357 L 70.25 C=120 PT 38.71 ( 24) Q 1549.19 F=0 F 0.00 PE 0.00 FM T 70.25 0.0629 PF 4.42 22 23 6.357 L 21. 50 C=120 PT 43.13 ( 23) Q 1549.19 F=2E F 25.14 PE 8.45 FR T 46.64 0.0629 PF 2.93 21 22DQ 100.00 6.340 L 7.00 C=140 PT 54.51 ( 22) Q 1649.19 F=2E F 46.22 PE 0.00 UN T 53.22 0.0538 PF 2.86 SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 8 GREYHAWK BLDG Q-R-S ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 20 21 5.914 L 80.00 C=150 PT 57.37 ( 21) Q 1649.19 F=T,E,GV F 72.41 PE 4.66 UN T 152.41 0.0664 PF 10.12 COMMENT: elevation difference from flow test taken here 12 20 5.914 L 25.00 C=150 PT 72.15 ( 20) Q 1649.19 F=T,4E,DCA F 132.50 PE 0.00 UN T 157.50 0.0664 PF 10.46 6" DOUBLE CHECK DETECTOR ASSEMBLY 8.18 PT 82.61 12) ------------------ 0 1 7.758 L 1.00 C=150 PT 96.15 1) Q 2049.19 F=0 F 0.00 PE 0.00 UN T 1.00 0.0265 PF 0.03 PT 96.18 0)