Loading...
HomeMy WebLinkAbout3250 GREY HAWK CT; ; AS050206; Permit10/31/24, 3:39 PM AS050206 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS050206 3250 GREY HAWK Job Address: Status: ISSUED CT Permit Type: SPRINK Applied 10/5/2005 Parcel No: 2210150200 Approved: 11/22/2005 Lot#: 0 Reference No.: Issued: 11/22/2005 PC#: Inspector: Project Title: BLDG. Z FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: LIFEGUARD FIRE PROTECTION STEF 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 about:blank Fees($) 1,150 Add'I Fees ($) 0 Owner: PALOMAR FORUM ASSOCIATES LP C/O DAVIS PARTNERS LLC 1420 BRISTOL ST N #100 NEWPORT BEACH CA Total($) 1,150 0 1/1 10/26/2006 12:06 7605979527 LUSARDI PAGE 04 .. Z· INSTAUA.TION OFSPRINa.Dsrstl.MS . . Contractor's Materlal and Teat Cartlflcato for Aboveground Piping ' . . . . . PROCEDURE . . .. ' .. Upon....., Gfffllllr, ~ IINllnll 11111n be midi 11,y Ill 1111111'1!:WI IIIPW ............... lly Aft,.._.. ie~Dlte, Allci.lwGll ... beOOIMl9d Md...-,.llftln~-~ connc:tlll"a~9""t--bj0b. .. ACMllcall ahll be ti~ OUl and lllcine!J br DDlh 1'91119Nnll~L ~ INII be p...-,.cl IDr ~ IUltlaMtl,,CM'IIM, and • Cllll'lll'KtDr. 1111 undllllllGd N __,. IIIPrtNl'IIII__.. llgnllUn In no warp,..,_ Mr dell!.--ClllllraalDr tarllullY !Mtelfll. poor ....,..._ orfllltura,.,Cllff!Plr wWllllPIM!I~ ~•1-11111111,nll!ON. :: •• Pnlplrty 1111111 Gizev~ ~,..I; u/_ · r11'>• -· -.b .. • : b"J-2 C.--0 . Piopertr ■--AUO··· ~ 1+.1a,.,tJK: C.r .. ~bfllPP"Mlll~C~<ZJ....AJ.; I#.-./~ I h, ~···.' Adlhll {1µ J~'~A..,") r;;;,c lYFPr , . PIIM t ..... ,loli ....... .,.., .... ~= ; q.No ~UNlllpp,IMCI· □No llno.111Pllli.,.,_. •·,I,,• ' Hal ,e111an In dllrgt al II,_ tqllfllmw,t bMn lllltlddM tllilaica1ID!lcll.-llllvl9ande■111 nm..,.,.,.. tl]vw · D No dill1,_~nr, ,no. ..... • . ~ .. HM~ ul 11_11 fl:lll~r,t Delft 11ft on h ~ CZl v. ON. 1, ~ ....... IMINllllcq•_ : IZl YM □--2. ·c.• 111111 mtNlllirrloa·hltruel• ~=-□No "\ 3. NFPAH • □ NCI ,, • 1o:111on .,. 11.ipplN llulldlngll • ....,. . YalrGI : Olltkll ,____ ..... MDCIII mam,a..,. ... ,o...... .... ,.,.,.i'\ tTLf'l 7."Z.1-13 ~'"' ..-,c:., 8prlnldlN ! ..,,,, I' I'\ l:!f"~_A Z"Z..l-,e,. 5, 'ii .. .,Cll"I "Ao "T\J/.h l::..J' Cji I 11.. 1-=:;..i'\ "Pl~ T"f,~f!':H Int. l.trc::""' ""NW -n-. a 1,,_ ,7,..,.... Plptand Tpcllplpa : ... 1ypa .cll lllllngl . . Malmllft Ima ..... Allrm : NaimllNca llll'Dllah"" ciann■lllllan . ~Dt 1--M• Modal Min~ ~ .law bllCalar li,y(.L ... J'rn.n -_4 ~ J\ .. ..., . ..,, -,,.,_ ... 0:0.D. .. . MIiia .... ~ . ' ,. ..... ,., ... I .,..... 9lllal-Mo ' I I . I . ·-_,:;.,-.,.. ... Tlrnt--"""Mffll ..... ·•· Dlyplpe ·lhrwllhtNI . , w.,' Mt Trtppatll ........ ..... op111l119 ·oannddn1.I l!Nlln --, • .,,...,I'll 1111 1111119t1,1 ·----Ml,._. 8IICXlndl "" ... ,. Mlnullt ..... -ND tar n"'9i ',' .. ·. lfna,--■i,I !VIA .. .. .. .. -, ,~• hamllfflit:::••-mmidoll I■_.. I FM~t-r■qlhl «t..-.,h~lnl,-cllla ..... ftGUUII.I Coiltnceor'■ MJtatai •d 'lat~ roc~d ...... 3 10/26/2006 12:06 7605979527 LUSARDI PAGE 05 : p,. ... r9dudng WMlell : T ... NICrlpllllfl Tuli Blllnk1'dllf 'gub!a SYS'IDISACCIPTANCE PlplnglllpeMlld E:lv• □No lllhlN &nll:m9'6,llylrttldtdnult far•-'> • • ·V.0NP DaN--"daltopelnl M .... · Model .uptmlllan lole 1llffilt'' "• I '" . I i.DD,IIDfl M•ltfld 8ellng SlaN p,Nlli,. enclllaor "'°"" '' lfno,ellplllq DOilud1 d!Qllt.,... .' YIMI IIINN? • • •. Y• '. I Na I llluldual flAIIIIU .. . •• (llc.lwlno) Inlet f PII) J . 0.-(Pt!) ln1111""1 I 0u111t ,(fll) 1✓ i:: 1//j_ . . JI"! -l~. C I Fw•• . . • Flr:wt(gpm) Pntumlllc: E'lllbll1h 40pal12,711W) ilr PfUIIR ll'ICI rHMUN dlllP, 'wtlldl lhlll nat NINd IM pal (0,1 11111) In 24 houN, T.i Pf9M'" llnkl ti normal _.r i..-, llrp!WIUN IUld mtlllll'9 M ..-,,. drllp; wtildl lflll not--.d 1" pal (0.1 tia,J Ill IOoin. • . .. lfl'ICl, ..... INRII Do~ ~ ••.,. apnlllter lllafllraelar tti.l addll!WI Ind ainvtlw ct.nlml1, IICldllffl IIIICII■ or d■rlvall\Ma al .adlum dlctdt, bnrll, Gr aller coll'llllv•dl■llllmts-nllf ul■d ,.;IMlng ■,■..,. • ._.,. ,.■lcd p Y• □. Na 11~11111■11111111ut■dln~. . CIJ Yt■ D No "" ,....._._..,......,,,,NIii MllllllalarD, aompllllld'P ,g(Ya □ Ne· ·, ..,_,.._ DoyouCl■llllyfl■t .. ~!.ll!J .. ~rtor:m~.t,:.-■11.-1n .. :. , • • • • ~ 0 ND ~ ·-·· '!'.'!'__,II • ?.!!l,IP:ll■ll!IIII:.• f:IIJ'tlluf'....,__of.at lelllt.AWR-11,1?-·---··, ·-·-. -.. ===--··-·" ··-·--··-· ... ,..... .. . -··-· --··---_, ~:. :.,:·•--•·•-.. •· -: . " :, ...... ' • .., -~ Do)'Du ca~ M 1w ~ .. ,·C1.1114Mt DUt'" _..,.,.. • • MVmlnlld qulllycan!IDI pl'IIOlldu,. ID .,...lltthlt II ct.a,,.~. tMI. openli,p· In plplnv -■moat\ .,_. .i■v and Olhar wtldlng Nlldllt lll't • 11111111111d, Md lhllt~ _,...,,... lllf lll,lrw 119"°' p■n■ll'■ladT Do !,'DU~ !hat )'DIii-. I CDlllla fa■ultto .,..,_ ... ■11.-,.-, ... llllr!Md' . ' ... HGmtE lU c.,;.--, o .... A □ NCI , l J lS-191 ZGCl2 Eclllaft 10/26/2006 12:06 7605'379527 LUSARDI 1~191 INSTALIADONOF,SPIUNKLU.·SYS't'Jr.HS _______ _.,; ___ ---,,1::..,_---,------------~ ... --... N1mtpl119 p!Vllldad --~--~• . .,~ .. ,,. , .. ·., ;•,:::,, •"•.I .. v..;.,,o .. No,:, ,---···•!'•''·: .. • • ·,•'. • : •• I J /I • •:,,,·; •;.. ··'H':••·!"•' :.;f,, •~:;. , .. ,,· t-·•, :-,•; 1· \1;, '··•·· • ._· •• • .,.;o.,.:• R•marb ~~--, ... . ......... ,1 ,, ... !---L~~~l(J.--i,4.:.-',~~:_~:,_:,_..:.S:~~a=~~~:..:.....:_~-..........:~;t..~~.;::; __ ::.~ • .....I ;• ... ; ,.J,t;;:-. • •• ro, t;. .. ,h .,,·· · .. , . ' ~ :··-~ '• !·: • :·• :.•••-.;,>•:•~ • •. ,• -Ji.··1 • , •• ,;.: .-. '..in,••\' ~•: • . .'f .... ·•.1.,.• .. : • •• : .. ·, '"·•· • ::-.... ·: •. :'·-' ·., ... •, • .:-!:;_:•r· •. !.~•1:·•~ :::-.··. r .. t ~-,~-· :',1· • ..::·\o·· •:. ;·:~•~1<1>.:1'••·.•'"·)·'•r,---<··,/ ~:,-,'-·~:t:':•:·.-~:•· ,_:.:"':::, ;:_<::,::i,,1:~---\•'--· :,· ,'.;.,_,.· DGUltE 11.1 ;~. ...... ~q-;,c• •.-~t:1 :-!·~ .. ~::.,:~:•i•,, :.~·:•:·r ~•.,,: ·,.t;•i ~._.,· :~. :: . ~-,·'.-•t.~-.· •' ,:.,.~ ... :.-.:. :: • i ': • . PAGE 06 • ·.5 10/26/2006 12:06 04/27/2806 03:52 24-16 7605979527 6J. 9-562-1695 LUSARDI KTA COrSTRUCTlON IHC contractor's Material and Test Certifiea!Q for Underground Piping Pllll0CEOURI Upon GOll!Planan dli,.ork. lfllpeel: n and ICRl lh•I bl """dll by lht aontraclor's '•Prt8111111flllll andw~nlDacl 1:1\1 Ill awnar'II lttpn!"nllllM . .., ... .,,.~ bl ~•r!IICtfid l!IG tY,lom 1,r, k1 ~r~i~O beta,. 1:onlll\C!Dr'!t PlrtOlll'lllfl!llllV .... 11'1. jOII. A 111rt11101lr N~ M llllld 11\11 Ind .1fpn■lf ti,/ bDII\ ...,,..,~, .. ~ .... !I. Cc,pi,!!111181 lie p,-p .. d iot 11Dp!DY]"9 aLl\hlllttla, ownerc, and tcll'\lllc:tor, It II UndeP!lleod lht OW'ltl'S ,911.-11nlat/ve", '!llgria!ur~ Ill no~ p111ludlc■s .,.,, ote1rn ... 111,t COl'llMDlar l'or ftQlly m1.ll!'l'ill, poor ~l'llm■111h1D, 11r111h.11'9 ID ODl!lply :villl •P~lfv ■ulhDrliy', •t(t1.tl, • .,.,.ft,, or loel!II ardlnenCt$, • ...: . -·· P,epercyrwne ·~ .,' J*,Oo-JlC ···~\).$ 1t.lt?""$S"· ~ ..... -_~ ....,__ ___________ _ .,_"'_•_riv_•_o_,.,_._"'-=_Q_ ~ 1-l~~t ;;.!Q,..__:C:;...11~---==;..:...1,,1-..-......._------~ Acc1111.o by,,pp,o,,1119 a111na1111,, tn•"'•~I U!'IIIIIIIOIJlld pip■11NI Jaln11 ------------··-·-·-----·--------------------t Ad:lre11 -----·------ln,IJlllllcm C: IIIOtms to ac:ar.pll!IC pi,:r,~ l!qulpnie, 100 iC :ipprovl!d u no. Ma11 d• vtaliorl:1 HU"'"°"'" c:h•gl( al nr• ~qi.1\:11T1C,nl l)"fl illl!IFl/1 .. IS 1!110 1i,o111on QI amrul v■llli!I! and en ,ni, mllnt,n~rr.~ c,r lhl!I new •qutpl'W!nt? trno.~ln ---------•······---·--·--·-----M■~• c-o,iiot II IIIP"'II""'"' inllr~~•loM M~ Clrt al'lo!l m11111en11nc1 ct11n1~..,1~n O'I prerriln,7 If 110, e,q,l~lt ----------.. ·•·-····-·-·------- D v,, 1Jij VII □Na D NII ,----------·-----··-· --··-··· li!.OOt!dlllOtl ' ~,urdlr!lt¥~ plplnglllllllodm·o~-.g 11J ! ,..fV~IT.._......,,,,r ... •!.~WIMtd by tcc-1\pFIFl~i· I If no, p~pl1l1> I Hod~1nn;-;;;;;.;-;;..-;;-· .. ··--····-··· • Thro11an ~11111v,e opcnc r· ~~"1er' □ r.,11~ o, tit!.=?.'.: . D P:1111""'"" 0 M,idr11nt butt __ ,.. ..... ·..,o ... pe_n_p_J1111_· ___ ....,.;_--4 ; L11■d•lftlll 11111".it ~eeldln~ 10Ut..£.. -·---11111ndllrd i,y (conpenyt c:J Ylf. □ fljo I If nQ. Hptet• ------····----····--------,-------------------1 • How tullhln1• 10'0' WU ob1al"41d . ~ublc 'o\11111' CJ Tank er ,~~,,..,~;, I 10/26/2006 1?14/27/21!181:t 12:06 83:52 7605979527 619-562-J.685 LUSARDI KTA Co-lSTRUCTIOl IMC PAGE 03 PAGE 25/29 AP.0\/'iG1'0UN1> PllE. ANO FmlNCl,S U-1'1 ~11ro.-11c •••• An ""' ur1 :lergrou!ld P,IPlrii:i hyd,~1c111r :.,~ 1e111,d st ,2«)__ p,,i • ltJr ~~ llaur. MUl'li Ha• T1rt1S al 1111' d11pnr1,,,.n1 cMMr.1!on1 and hydra"ts lnlergl\111f'llbll wllh 1!1D!II al lltl Cftptrlfflll'tt ln!l'l/1!1111,;i til~'"' Ol'ts CIMo 1------..-----------·--------------------------1 0Na left I, IIMOO 1-T~-... ~-,-.-,.,-..--~--::·---· 1-----~"""'~"-""'-~'-1_ Nt,li• all lllflllllllg co,,1.-.tnlnr ._,,; ...... .....-.,!....:...-~;.;.....,:;.;;__:;;_;,.__,.....,...:....;:!,....--------------1 TIISb wltn1n1d 11v notJRE 10-11>.1 Co,1ffn1w {1)11The lln'll)Unt of 11:f~iige at the joinl~ .;h~II Ml CllCCCd 2 qt/hr (1,89 L/hr) ptt 100 pskct:1 or jol.c,,.,. inapcclive of pipe diarn•ter. ' (t)•Thnr.11ou.l\to('lealcn~c,~eelAed in 10.Hl.!.f.4(1) shall be ptrmlu1d to be locrr;asecl by l fl o,i (30 nil! per inch 111!~ dlamclr;r !M" houc :-or eac'1 me~t-mn~d v,d\·e i~r!)l:ulng the test sec11on, (S) tt tlry l,i.aff'!.l h.ydn,11 I~ 11rc ~IMttd with t.hc m.-.in v.ilw open so dt• h,"Vc:b;11,r1 an! \IJltl.er pr~mirc, an 110,:iit.ional 5 0 01/ min (lSO m\/minl r. £ IC1'kale shall be pi::m1i•.ttri tor ea1;h h,clranL . (t) The i,,mouat or h:al:"Bc in buried piping shall be mea- llUtt:d a.1 the specified tr_u pres.sure b:,-pun,ping from• callbn.tc:d C()nt,ahirr. Cluipttt 11 H),b:'1tulic Cakulat~t11-'!I 11.l • Clllcuwio111 In E.,Jtlllb Umvi. Plpc C,k,ion \0~1-:• .,hall be drctcnr,i,ned bued 011 the Huen-Willi11.111s formula. ai; fol. law11: "'here: p ,. frictl~nal resi,"'-"ce (psi/lt or pipe) Q. "' now (81)m) C = friction. lo,, coelflclc{Jt d "' 11ctu•I lntent11l diameter orptix (ln. l 11,2 CalculadGU iD SI U,al'ls. l'lpc l'riction loam J'ball ba clc- tcn:nined b1Ued ot11'he Ma1.eo..-William11 rormul:i. in St ,,oit.r., a! roi,ows: where: t ... ., trktlon:J mht.111'l(rt (bar/111 of pipe) Q.. = How (L/minJ C • f\:iction le11 cOt!'&irc.h:ttl. , .. ., KlWII. in1c:rM.I dlametero£plpe (mm) cba,~r 1 t Abcm!potm.d Pifc and Flttmp 1!.I Gcoenl. A~ound pipe a,nd Rtdnl' 1\'l~l comply w.ith lbe ap_plidl\,le 1tttlons of Cbapter,, 6 and 8 of NFPA 13, :z. • ------- MATERIAL DATA SUBMITTAL GREYHA\VK BUSINESS PARK BLDG. Z, 3250 GREYHA\.VK CT. CARLSBAD, CA. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DRIVE, STE. F OCEANSIDE! CA 92056 760-806-9997 • 760-806-4813 FAX 1:qca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 C a: Tel: (414) 570-) 558-5236 Fax: (414) 570-501 ) 877-1295 Series TY-FRB -2.8, 4.2, 5.6, and 8.0 K-facto Upright, Pendent, and Recessed Pendent Spri lclers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, l,Jpright and Pendent Sprinklers described in this data sheet are quick response -standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Serles TY-FRB Pendent Sprinkler, where ap- plicable, Is Intended for use In areas with a finished ceiling. It uses either a two--piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 314 inch (19, 1 mm) of total adjustment from the flush pendent position, or a two--plece Style 20 ( 1 /2 inch NPT) or Style 30 (314 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utiltzed to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP700 for the 1NSTALLER WARNING• that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or Its compo- nents and cause the sprinkler to fail to operate In a fire situation or cause it to operate prematurely. Page 1 of 8 mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli• cable approval agencies, the testing Is not representative of all possible cor- rosive atmospheres. Consequently, it Is recommended that the end user be consulted with respect to the sultablllty of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the • Serles TY-FRB Pendent Sprinklers are detalled in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Serles TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the appllca• ble standards of the National Fire Pro- tection Association, In addition to the standards of any other authorities hav- ing Jurisdiction. Failure to do ao may Impair the performance otthell8 de- vices. The owner ls responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Afodel/Sprinlcler Identification Numbers TY1131 • TY1231 • TY2131 • TY2231- TY3131 • Upright 2.8K, 1/2"NPT Pendent 2.81(, 1/2"NPT Upright 4.2K, 1fl"NPT Pendant 4.2K, 1J2"NPT Upright 5.6K, 1/2"NPT JULY, 2004 f TY3231 • TY4131- TY4231- Tecllnic Data Approvals UL and C-UL Listed. 5.6K, 1J2"NPT a.OK, 3/4"NPT a.OK, 3/4"NPT FM, LPCB, and NYC roved. (Refer to Table A for mplete approval Information Including corrosion resis- tant status.) Maximum Working reasure 175 psi (12,1 bar) Discharge Coefflcle t K = 2.8 GPM/psi1'2 ( 0,3 LPMA>ar112) K = 4.2 GPM/psi112 ( 0,5 LPMJbar112) K = 5.6 GPM/psi112 ( 0,6 LPMA>ar112) K = 8.0 GPM/psi112 (1 5,2 LPMJbar112) TFP171 Page2of8 ESCUTCHEON PLATE SEATING SURFACE I 2-1/4' (57,2mm) 1-9/16" (39,7mm) 112· ** NPT 7/16" (11,1 mm) NOMINAL MAKE-IN I SSP DEFLECTOR* PENDENT 1 • Frame 2-Button 3 • SeaHng Assembly 4-Bulb 5 -Compression Screw STYLE 10 or 20 RECESSED ESCUTCHEON 6 • Deflector 7-Bushing FIGURE1 ssu* DEFLECTOR 7/16' (11,1 mm) NOMINAL MAKE-IN 2-3116' (55,6mm) l 1/2' NPT** UPRIGHT * Temperature rating is Indicated on defle orifice seat on frame. "Pipe thread connections per ISO 7/1 speclal request. QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRIN ESCUTCHEON PLATE SEATING SURFACE I 2-31'16' (55,6mm) 1-1/2" (38,1 mm) 1/2' ** NPT 7N6" (11,1 mm) NOMINAL MAKE-IN I 2.B K-FACTOR, 1/2 INCH NPT STYLE 10or20 RECESSED ESCUTCHEON ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3116' (55,6mm) ' SSP DEFLECTOR* PENDENT L ,a,r --, CMA RECESSED PENDENT 1/2' NPT** UPRIGHT 1 -Frame 2-Button Finishes 3 -Sealing Assembly 4. Bulb 5 • Compression screw 6 -Deflector FIGURE2 * Temperature rating is indicated on de orHice seat on frame. ** Pipe 1hraad conneclions per ISO 7/1 ca special request. QUICK RESPONSE SERIES TY-FRB UPRIGHT {TY2131} AND PENDENT {TY2231) SPRJN. 4.2 K-FACTOR, 1/2 INCH NPT Bulb .............. Glass TFP171 6 IEJll----5 ---4 ....,_ __ 2 3 s* 5 2 3 Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Pbyslcal Characteristics Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . Compression Screw . . . . . Bronze Deflector . . . . . . . Copper/Bronze Bushing (K=2.8) . . . . . . . Bronze The gtass Bulb con ns a fluid which expands when expo to heat. When the rated temperatu is reached, the fluid expands sufflcle ly to shatter the glass Bulb, allowing the sprinkler to activate and water to ow. . . . . . Beryllium Nickel w/Teflont ~ :::, 0 +- TFP171 Page 3 of 8 ESCUTCHEON PLATE SEATING SURFACE I 2-3/16' (55,6mm) 1-1/2' (38, 1 mm) 112' ** NPT 7/16" (11, 1 mm) NOMINAL MAKE-IN ~ STYLE 10 or 20 RECESSED ESCUTCHEON ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN ~~ 2-3/16" (55,6mm) t I SSP DEFLECTOR* PENDENT 1/2" NPT** UPRIGHT SECTION 1 -Frame 2 -BllltOn 3· Sealing Assembly 4 -Bulb 5 -Compression Screw 6 -Deflector * Temperature rating Is Indicated on defl or adjacent to orifice seat on frame. -Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE3 QUICK RESPONSE SERIES TY..fflB UPRIGHT {TY3131) AND PENDENT (TV3231) SPRINi 5.6 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-5118" (58,7mm) 1/2" (12,7 mm) 314• ** NOMINAL NPT MAKE-IN _l SSPDEFtECTOR* PENDENT 4 • Bulb STYLE 30 or -40 RECESSED ESCUTCHEON 6 • Dellector ssu* DEFLECTOR 1/2" (12,7 mm) NOMINAL MAKE..iN 2-1/4" (57,2 mm) ...-NPT~ UPRIGHT 1 • Frame 2-Button 3-SeaUng Assembly 5 • Compression Screw * Temperature rating Is Indicated on def orifice seat on frame. -Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKi ERS Design Criteria 8.0 K-FACTOR, 314 INCH NPT Usting is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ), Only the Style 10, 20, 30, or 40 Recessed Escutch-eon, as applicable, is to be used for recessed pendent Installations. lnstallat The Series TY-FRB S installed In accordan Ing Instructions: NO s* 5 2 3 The Series TY-FRB Pendent and Up- right Sprinklers are Intended for fire protection systems designed In ac- cordance with the standard Installation rules recognized by the appHcable Listing or Approval agency (e.g., UL Do not Install any buli type sprinkler ff th& bulb Is cracked or there is a Joss of I/quid from the bulb. 'ith the sprinklsr Pageillof 8 SPRINKLER RNISH (See Nola 7) K TYPE TEMP. BULB NATURAL I CHROME l1 WHITE ... LIQUID BRASS PLATED POL VESTER 135°F/57°C Orange PENDENT 155°F/68°C Red (TY1231) 175"Fn9"C Yalow 1,2,3,5 and UPRIGHT 200"F/93°C Graen 2.8 {TY1131) 286°F/141°C Blue 1/2" NPT 135°F/57°C Orange RECESSED 155°F/68°C Rad PENDENT {TY1231)* 175"F/79°C Yellow Figures 200°F/93"C Green 1, 2, 5 135°F/57"C Orange RECESSED 155"F/68°C Red PENDENT crv1231r 175"F/79"C Yalow Figure 6 200°FJ93"C Green 135°F/57°C Orange PENDENT 155"F/68°C Rad {TY2231) and 175°F/79"C Yellow UPRIGHT 200"F/93"C Green 4.2 (TY2131) 286°F/141°C Blue 112· 1, 2 NPT 135°F/57°C Orange RECESSED 155"F/68"C Red PENDENT {TY223ft 175°F/79°C Yellow Flgure7 200"F/93"C Green 135°F/57°C Orange RECESSED 155"F/68"C Rad PENDENT (TY2231)** 175"Fn9"C Yenow Figure a 200"F/93"C Graen NOTES· 1. Usted by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Usted by Underwriters labondofles, Inc. tor use In Carada (C--UL) as Quick Response Sprinklers, 3. Approwd by Factory Mutual Research CorporatlOn (FM) as Quick Response Spm• kleis. • 5. Approwd by 1he City of New~ under MEA 354-01-E. 7. Where ~ Coated Sprinklera are noted to be UL and C--UL Ustad, the &plin· klers are UL and C-UL Usted as Col1'08lon Raelstant Sprinklers. • Installed with Style 10 (1/2" NPT) or Style 40 (314" NPT) 314• Total Adjustment Rec:essed Escutcheon, as appllcable. -Installed with Style 20 (112" NPT) or Style 30 (3/4" NPT) 1/2" Tot.i Adjustment Recessed Esculcheon, as applcable. ... Fnune and Deftaclor only. Usllngs and approvals apply to color (Special Order'). NIA: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS held horizontally, a small air bubble should be present. The diameter of the air bubble is approximalsly 1/16 Inch (1,6 mm) for the 135°F/57°C to 3132 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 lo 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 314 TFP171 inch NPT sprinkler • t should be ob- tained with a torque f 10 to 20 fl.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7Nm)of eistobeused ID Install sprinklers 314 NPT con- nections. Higher /ev. of torque may distort the sprinkler nlet and cause leakage or impairmen of the sprinkler. Do not attempt to e-up for insuffi- cient adjustment In e escutcheon plate by under-or o r-ttghlsnlng the sprinkler. Readjust th position of the sprinkler fitting to sui The Serles TY-FRB dent and Up- right Sprlnlclers m t be Installed in accordance with the lowing instruc• tlons. Step 1. Pendent spri klers are to be Installed In the pend t position, and upright sprinklers are be Installed in the upright position. Step 2. With pfpe plied to the pipe thra the sprinkler Into the Step 3. Tighten the sprinkler fitting using ly the W-l'ype 6 Sprinkler Wrench f. Figure 13). With reference to Fig res 1, 2, 3, and 4, the W-Type 6 Sprin er Wrench Is to be applied to the s rlnkler wrench flats. The Serles TV•FRB dent Sprinkler, m accordance with the tlons. Step A. After installl g the Style 10. 20, 30, or 40 Mountin Plata, as appli• cable, over the sprln ler threads and with pipe thread seal t applied to the pipe threads, hand • en the sprin• kier Into the sprinkler lttlng. Step B. Tighten the prlnlder into the sprinkler fitting using ly the W-"lype 7 Recessed Sprtn Wrench (Ref. Figure 14). With refe nee to Agure 1, 2, 3, and 4, the W-7 Recessed Sprinkler Wrench is o be applied to the sprinkler wrench ts. StaP c. After the cei ing has been in- stalled or the finish t ha& been ap- plied, slide on the 10, 20, 30, or 40 Clos1Xa over the Serles TV-FRB Sprinkler and push e Closure over the Mounting Plate untll Its flange comes in contact Wit the ceiling. TFP171 PageSof8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME WHrTE-LEAD LIQUID BRASS I PLATED POLYESTER COATED 135°F/57°C Orange PENDENT 155"F/68"C Rad (TY3231) 1,2,3,4,5,6, 7 1,2,3,5 and 175"Fll9"C Yalow UPRIGHT 200"F/93"C Green 5.6 (TY3131) 286°F/141°C Blue 1/2" NPT 135"F/57°C Orange RECESSED 155"Fl68°C Red PENDENT 1,2,4,5 NIA {TY3231)0 175°Ff79°C Yellow Flgure9 200,=/93-C Green 135°F/57°C Orange RECESSED 155°F/68"C Red PENDENT 1, 2, 3, 4, 5 1,2,4, 5 NIA {TY3231r" 175,=ng-c YeUow Flgiwe10 200°F/93"C Green 135°F/57"C Orange PENDENT 155,=f68"C Rad (TY4231) 1,2,5 and 175"F/79"C Yellow 1, 2, 3, 4, 5, 6, 7 UPRIGHT 200°F/93"C Green ao (TY4131) 286°F/141°C Blue 3/4" NPT 135°F/57"C Green RECESSED 155"F/68"C Orange PENDENT 1,2,4,5 NIA (TY4231)" 175°Ff79°C Red Figure 11 200°F/93"C Yellow 135°F/57°C Orange RECESSED 155"FJ68"C Red PENDENT 1,2,3,4,5 NIA {TY4Z'1)-175"Fll9°C Yellow Flgure12 200°F/93°C Graen NOTES: 1. Usted by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Usted by Underwfitara Laboratories, Inc. for use In canada (C•UL) ea Quick Reaponee Sprlnklera. 3. Approved by Factory Mutual Research CQrporation (FM) as Qulc:k Response Sprinklers. 4. ApproY9d by the LDas Prevanllon Cerllflcatlon Board (LPCB Ref. No. 007k/04) aa Quick Response Sprinklers; l10MMI , the LPCB does not rate the lhermal aenslllvlly of raceasad aprlnklera. 5. Approvad by the City of New York under MEA 354-01-E. 6. VdS Approved (For detalla contact Tyco Fire & Buldlng ProductS, Enschada. Netherlands, Tel. 3H;3•428-4444/Fax 31 ·53-428-3377). 7. Approved by the Loea Prevention Certification Board (LPCB Rsf. Na. 094al06) as Quick Reaponse Sprinklers. 8. Where Polyester Coated and Lead Coated Sprlnlclans are noted to be UL and C-UL U&tad, the aprtnlders are UL and ~IJLU&tadas Corrosion Resiatant Sprinlclera. Where Lead Coated Sprinklers are noted to be FM Approved, the eprtnld81'11 are FM • asa Cc,rroaion Resistant Sprfnlclera. * Installed with Style 10 (1/2" NPT) or Style 40 (314" NPT) 3/4" Total Adjustment Recessed Escutcheon, as appllcable. " Installed with Style 20 (1/2" NPT) or Style 30 (314" NPT) 1/2" Total Adjustment Recessed Eecutcheon, aa applicable. ••• Frame Md Deflector only. Uatlnga and approval9 apply to color (~I Order). NIA: Not Available TABLES LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page8of8 518:t:1/4" (15,9:16,4 mm) FACE OF SPRINKLER FITTING aDSURE 2-7/8" DIA. ;l (73,0mm) 2-1/4' DIA. -:i 1s1,2mm> TI 3/4" 19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1~1/8" (12,7:1:3,2 mm) FACE OF SPRINKLER FITTING \ 2·7/8" DIA. ;l (73,0mm) 2-1/4" DIA. -:i (57,2mm, Tl TFP171 12" (12,7 mm) 1/4" (6,4 mm) SERIES TY-FRB 13/16' (20,6 mm) FIGURE5 SERIES TY-FRB RECESSED PENDENT RGUREB SERIES TY-FRB RECE. WITH TWO-PIECE 314 INCH TOTAL ADJUSTJfENT STYLE 10 RECESSED ESCUTCHEON WITH TWO-PIECE 1/2 INCH TO ~#U~ 'NT STYLE 20 RECESSED 2.B K-FACTOR, 1/2 2.B K-FACTOR, 112 INCH NPT 518:1/4" (1S.W,4mm) FACE OF SPRINl<LER FITTING CLOSURE 2-7/8' DIA. ;l (73,0mm) 2-1/4" DIA. (57,2mm) ,;J FIGURE7 3/4" 19,1 mm 1/4" (6,4 mm) 3/4" (19,1 mm) 1/&118" (12,7:1:3,2 mm) FACE OF SPRINKLER FITTING CLOSURE 2-718" DIA. ;l (73,0mm) 2-1/4" DIA. ---:1 (57,2mm) r I RGUREB 1· /4" 1,8 mm • (25,4mm) SERIES TY-FRB RECESSED PENDENT WITH TW~PIECE 314 INCH TOTAL ADJUSTIIENT STYLE 10 RECESSED ESCUTCHEON SERIES TY-FRB RECESSED~ NDENT WITH TWo-PIECE 112 INCH TOTAL _,.,~TIIENT STYLE 20 RECESSED ESC HEON 4.2 K-FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH 'PT Care and Maintenance The Serles TY-FRB Sprinklers must be maintained and serviced In accord- ance with the following Instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler opsralion In a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of conoslon must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after Installation. Sprinklers dam- aged by dropping, triking, wrench twist/slippage, or the Ike, must be re- placed. Also, replace y sprinkler that has a cracked bulb that has lost liquid from Its bulb. Ref. Installation Section). Frequent visual ins ons are rec- ommended to be initi Hy performed for corrosion resistant d sprinklers, after the installation has been com- pleted, to verify the I rlty of the cor- rosion resistant coa Ing. Thereafter, annual inspections per NFPA 25 should suffice; h r, instead of in- specting from the floo level, a random sampling of close-u visual Inspec- tions should be mad so as to better determine the exact sprinkler condi- TFP171 5.18±1/4" (15,9:t6,4 mm) FACE OF SPRINKLER FITTING 2-7/W'DIA.;l (73,0 mm) 3/4" 19, 1 mm) 2-,,4• DIA. --j 1/4" (6,4 mm) (57.2mm1 r I 112:1:118" (12,7:ta3,2 mm) FACE OF SPRINKLER FITTING \ 2-7/B"OIA. ;l (73,0mm) 2·1'4" DIA. -j <S1.2mm> r I Page 7 of8 fZ' 12,7mm) 1/4" (6,4 mm) 118" (3,2mm) =l CLOSURE SERIES TY•FRB 1-1/4" 31,8mm 3,14" (19,11ml) Q.OSURE 1-/4" 1,8mm "125,4mm) FIGURES SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 5.111:1/4" (15,9:IB,4 mm) FACE OF SPRINKLER FITTING CLOSURE ~';;~=;l 3/4" 19,1mm 2-1/4' DIA. j 1/4' (6,4 mm) <57•2 mm) MOUNTING PUI.TE SERIES TY-FRB FIGURE11 1-5.116" 33,3mm 13/16" (20,6 mm) FIGURE10 SERIES TY-FRB RECESSED WITH TWO-PIECE 1/2 INCH TOTAL A STYLE 20 RECESSED ESCU 5.6 K-FACTOR, 1/2 INCH 112:s:11'8" (12,7:t,3,2 mm) FACE OF SPRINKLER FITTING FIGURE12 fZ' 12,7 mm) 1/4" (6,4 mm) SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PS DENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON WITH TWO-PIECE 112 INCH TOTAL A TltlENT B.0 K-FACTOR, 314 INCH NPT tlon and the long term Integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), In addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relatlve to any questions. It Is recommended that automatic STYLE 30 RECESSED ESCU11 ON B.0 K-FACTOR, 314 INCH T WRENCH RECESS (END "A" USED FOR 112• NPT MODELS) WRENCH RECESS (END 'B" USED FOR 3/4' NPT MODELS) FIGURE13 W-TYPE 6 SPRINKLER WRENCH IN EN WITH WRENC sprinkler systems be Inspected, local requirements and/or national tested, and maintained by a qualified cod Inspection Service In accordance with • es. Page8of8 TFP171 P/N 57-XXX-X-XXX I I I TEMF ERATURE MODEUSIN RrnNG SPRINKLER 330 2.8K UPRIGHT (1/2"NPT) TY1131 135 1~ "FJ57°C 331 2.8K PENDENT (1/2"NPT) TY1231 1 NATURAL BRASS 155 15!: ~F/68°C 340 4.2K UPRIGHT (1/2"NPT) TY2131 4 WHITE POL VESTER 175 17E ~Fne·c 341 4.2K PENDENT (1/2"NPT) TY2231 3 WHITE (RAL9010)0 200 2CX °F/93°C 370 5.6K UPRIGHT (1/2"NPT) TY3131 9 CHROME PLATED 286 286' F/141"C 371 5.6K PENDENT (1/2"NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 B.0K PENDENT (3/4"NPT) TY4231 • Eastern Hemisphere 1 :alesonly. TABLEC PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when ~d for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Flre Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with lyco Flre Products or for products and components which have been subject to misuse, Improper installatiOn, corro- sion, or Which have not been installed, maintained, modified or repaired In ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or repla'Ced, at T~ Fire Products' sole option. Tyco Fire Products neither as- sumes. nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or Incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHAU TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE;- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OE ANY AND ALL OTHER WABBANZMSEXPRESSOR tMPLfEQ, INCLUQING WARRANT/ES OF MERCHANTABILITY AND EU-NESS FOB A PARTICULAR Pl/B- Ordering Procedure ~ .. lecal distributor for avail- abf.t.:::-11111 nama.Refefto the Prlc:e Ust for complele lladng of Part Numbefls. Sprinkler Aaaembllea with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series ti'-FR8 (specify Pendent or Upright) Sprinkler with (speoify type of finish or coating), PIN (specify from Table C). Recesa1d E • • : Specify: Style (specH ·) Recessed Es- cutcheon with (spei ffy finish), P/N (specify). 112" (15 mm) Slyle10 Chrome Plated . . . . . . . . . . . PIN 58-701-9-010 Whb Coel8d . . . . . . . . . . . . PIN 66-701-4-010 Whb RAl.9010".. . . . . . . . . PIN 58-701-3-010 Bralll Plallld ............. PIN 58-701-2-010 1/2' (15 mm) Style 20 Chrome Plated . . . . . . . . . . . PIN 56-7~-010 White Coated ............. PIN 58-705-4-010 White RAL.9010-.. , , . , . , . . PIN 58-705-3-010 Brue Plated ............. PIN 58-705-2-010 3'4' (20mm) Styte 30 Chiame Plllhld . . . . . . . . . . . PIN 58-705-8-011 White Cot.lld· .. . . . . . .. .. . PIN 58-705-4-011 Whlbt RAl..9010" .......... PIN 58-705-3-011 Brue Plal8d . . . . . . . . . . . . . PIN 58-711&-1!-011 3/4' (20mm) Si,te40 Chrome Pllll,lecl ........... PIN 58-700-9-010 White Coated . . . . . . . . . . . . PIN 58-700-4-010 White RAL.0010" .......... PIN 58-700-3-010 B111A Plalad . . . . .. . . . . . . . PIN 68-700-2-010 • Eastern H1~18phe19 ..... anly. Sprlnlder Wrench: Specify: W-Type 6 S1~rtnkler Wrench, PIN 5&-000-6-387. Specify: W-Type 7 S >rinkler Wrench, PIN 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Camon Avenue, Lansdale, Pemsylvanla 19446 -tqca / Fire & Bu,1ding f Products Technical Services: Tel: (BOO) 381-9312 / Fax: (BOO) 791-5500 Oern Customer ServlceJSales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010, (800) sn-1295 Series EL0-2318 -11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description The 11.2 K-factor, Series ELO-231 B, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin- klers of the frangible bulb type. They are "standard response -spray sprin- klers" that produce a hemispherical water distribution pattern below the de- flector. The 11.2 K-factor, ELO-231 B Sprin- klers were subjected to full scale, high- piled storage, fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor stand- ard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, ELO-231 B Sprinklers - making their use highly advantageous in high density applications, such as the protection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy com- ponents used in Series ELO-231B sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lead, and polyester coated sprin- klers have passed the standard corro- sion tests of the applicable approval agencies, the testing is not repre- IMPORTANT Always refer to Technical Data Sheet TFP700 for the •tNSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 sentative of all possible corrosive at- mospheres. Consequently, it is recom- mended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The ef- fects of ambient temperature, concen- tration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive na- ture of the chemical to which the sprin- klers will be exposed. An upright intermediate level version of the Series ELO-231 B Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-231 B Up- right Sprinkler with the WSG-2 Guard & Shield, and a pendent intermediate level version of the Serles ELO-231 B • Sprinklers can be obtained by utiliz- ing the Series ELO-231 B Pendent Sprinkler with the WS-2 Shield. If there is a possibility of the pendent interme- diate level version being exposed to mechanical damage, a G-2 Guard can be added. WARNINGS The 11.2 K-factor, Series EL0-2318 Upright and Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Installation of Series EL0-2318 Pen- dent Sprinklers in recessed escutch- eons will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. JANUARY, 2005 l,. . : ·.-~:-:=---:--·_ :: ------~--•. : -.----~=~3-:· - ~ .:~~---:·?-"-: ::---:--~--~ ·,· . ~ TFP342 Page 2 of 6 TFP342 SPRINKLER FINISH TYPE TEMPERATURE BULB NATURAL I CHROME LEAD I WAX I WAX LIQUID BRASS PLATED COATED COATED OVER LEAD UPRIGHT 1ss°F1sa0c Red 3 (TY5151 200°F/93°C Green & 1,2,3, 4 TY5851) 2as°F1141°c Blue 3 I 3(•1 155°F/68°C Red 3 PENDENT 200°F/93°C Green (TY5251 1,2, 3,4 286°F/141°C Blue 3 I 3(•) NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL Listed). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL Listed). 3. Approved by Factory Mutual Research Corporation (FM Approved). 4. Approved by the City of New York under MEA 291-04-E. (a). FM Approved for a maxlmum celling temperature of 150°F/66°C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K-FACTOR SERIES EL0-2318 UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Identification Numbers TY5151 -Upright 11.2K, 3/4"NPT TY5251 • Pendent 11.2K, 3/4" NPT TY5851 -Upright 11.2K, 1/2"NPT TY5151 is a redesignation for C5151. TY5251 is a redesignation for C5251, G1871, and S2531. TY5851 is a redesignation for C5851. Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12, 1 bar) Discharge Coefficient K = 11.2 GPM/psi112 (161,4 LPM/bar112) Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame ............. Bronze Cap .............. Bronze Sealing Assembly . . . . . . . . . . . . . . . . . Beryllium Nickel w/Teflont Bulb (5 mm dia.) . . . . Glass Compression Screw . . . . . Bronze Deflector . . . . . . . . . . . . Bronze t Registered trademark of DuPont. Design Criteria UL and C-UL Listing Requirements The 11.2 K-factor, Model ELO-231 B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with NFPA 13 standard sprinkler posi- tion and area/density flow calculation requirements for light, ordinary, or ex- tra hazard occupancies with a mini- mum residual (flowing) pressure of 7 psi (0,5 bar) In wet or dry pipe sprinkler systems, or they are to be installed in accordance with NFPA 13 standard sprinkler position and area/density flow calculation requirements for high piled storage occupancies (solid piled, palletized, rack storage, bin box, and sheH storage including but not limited to Class I-IV and Group A plastics) with a minimum residual (flowing) pressure of 10 psi (0,7 bar) for wet or dry pipe systems. The following example is typical of the type of arrangement permitted by NFPA 13. For all combinations of lesser and greater building heights, lesser and greater storage heights, storage arrangements, commodity classifications, and lesser or greater required design densities, refer to NFPA 13 for specifics. Example: NFPA 13 provides ceiling only protection (i.e., no in-rack sprin- klers) criteria using open frame (i.e. no solid shelves) single, double, multiple- row, or portable rack storage (without TFP342 * Temperature rating is indicated on deflector. ** Pipe thread connections per ISO 7/1 can be provided on special request 2-13/16' (71,4 mm) TYP. 7/16' (11,1 mm) NOMINAL MAKE-IN UPRIGHT TY5851 ... T UPRIGHT TY5151 1/2" (12,7 mm) ~MINALMAKE-IN THREAD RELIEF RGURE1 PENDENT TY5251 11.2 K-FACTOR SERIES EL0-2318 314•** NPT 2 3 4 5 6 CROSS SECTION Page 3 of6 Components: 1 -Frame 2 • Seal Assembly 3 • Cap 4 -Bulb 5 • Compression Screw 6 • Deflector • UPRIGHT-314" NPT (TY5151), UPRIGHT-112• NPT (TYSB51), AND PENDENT-3/4° NPT (TY5251) SPRINKLERS the need for in-rack sprinkler protec- tion) of cartoned or uncartoned unex- panded Group A or B plastics, or, car- toned expanded Group A or B plastics, with: • a storage height of up to 20 feet (6, 1 m); • a maximum ceiling height of 27 feet (8,2 m); • a minimum deffector to top of stor- age clearance of 18 inches (457 mm); • a minimum design density of 0.60 gpmlft2 (24,4 mm/min); • a minimum residual (flowing) pres- sure of 10 psi (0, 7 bar); • a minimum design area of 2000 ft2 (186 m2) for wet systems or 2600 ft2 (242 m1) for dry pipe systems FM Approval Requirements The 11.2 K-factor, Model ELO-231 B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with the applicable "control mode den- sity/area" guidelines provided by Fac- tory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Installation The Series ELO-231 B Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C to 3132 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 314 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. {13,4 to 26,8 Nm). A maxi- mum of 30 ft. lbs. (40, 7 Nm) of torque is to be used to install sprinklers with 3/4 NPT connections. A leak tight 1/2 inch NPT sprinkler joint should be ob- tained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to Install sprinklers with 1/2 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS (END "A") RGURE2 W-TYPE 3 SPRINKLER WRENCH clent adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series EL0-231 B Upright and Pendent Sprinklers must be installed in accordance with the following in- structions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 3 Sprlnkler Wrench (Ref. Figure 2), except that an 8 or 1 0 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Page 4 of 6 Figure 1, the W-Type 3 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1 /8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed onfy at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which Is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of Initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-haff inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. Care and Maintenance Series ELO-231 B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system control valve for maintenance work on the fire protection system that it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facb.l rer should be contacted relative to any questions. TFP342 Jt Is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national code. limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (1 O) years from date of ship- ment by·Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired In ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL,. INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY ts MADE IN LIEU Of ANY AND AU OTHER WARRANTIES EXPRESS OB IMPLIED.INCLUDING WARRANTIES Of IIERCHANTASILfTY AND FIT-NESS FOR A PARTICULAR Pl/B· l!DS£ TFP342 Ordering Procedure A Part Number (P/N) is not specified when ordering sprinklers with thread connections per ISO 7/1. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connection: Specify: (specify SIN), 11.2 K-factor, (specify temperature rating), Series ELO-231B Standard Response (spec- ify Pendent or Upright) Sprinkler with (specify finish), P/N (specify from Ta- ble B). Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries EL0-2318 Sprinklers, P/N (spec- ify). Red for 155°F . . . . . . . . . . . . . P/N 56-065-1 • 155 Blue tor 200"F and 286"F. . . . . . . . . . . . . . . . . P/N 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200"F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 1so°FJ. 510 512 501 Page 5 of 6 P/N 50-XXX-X-XXX SPRINKLER TEMPERATURE TYPE UPRIGHT 3/4" NPT (TY5151) PENDENT 3/4" NPT (TY5251) UPRIGHT 1/2" NPT (TY5851) 1 9 6 7 8 NATURAL BRASS CHROME PLATED WAX COATED LEAD COATED WAX OVER LEAD 155 200 286 TABLES PRODUCTSYMBOLNUMBERSELECTION 11.2 K-FACTOR SERIES EL0-2318 RATING 155°F/68"C 200"F/93°C 286"F/141"C STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS Page6 of 6 TFP342 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 1:qca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 11 Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010/ (800) an-1295 Series TY-B -2.8, 5.6, and &O K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described In this data sheet are standard response -standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is Intended for use in areas with a finished ceiling. It uses a two-piece Style 1 O (1/2 inch NPT) or Style 40 (314 Inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1 /2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19, 1 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is IIIPORTANT Always refer to Technical Data Sheet TFP700 for the •1NSTALLER WARNING• that provides cautions With respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or Its compo- nents and cause the sprinkler to fail to operale in a fire situation or cause it to operate prematurely. Page 1 of 8 not representative of all possible cor- rosive atmospheres. Consequently, It is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Serles TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Serles TY-8 Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing Jurisdiction. Failure to do so may Impair the performance of the• de- vices. The owner is responsible for maintain- Ing their fire protection system and de- vices In proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1151 ■ TY1251 ■ TY3151 • TY3251 - TY4151 - TY4251 • TY4851 • TY4951- Upright 2.8K, 112•NPT Pendent 2.8K, 112•NPT Upright 5.6K. 112•NPT Pendent 5.6K, 112•NPT Upright 8.OK, 314•NPT Pendent a.OK, 314•NPT Upright a.OK, 112·NPT Pendent a.OK, 112·NPT JULY, 2004 •• ~ . • • •. "· rtl!li I . . . . a...... TFP151 I i j :: a: i :::, 0 +- Page 2ot 8 ESCUTCHEON PLATE SEATING SURFACE I 2-1/4" (57,2mm) 1-9/16" (39,7mm) 1/2" ** NPT 7/16" (11,1 mm) NOMINAL MAKE-IN l ssP* DEFLECTOR ssu* DEFLECTOR 6 tE3f----5 ---4 1',----2 ~~,..~-3 1 ....__..J,1' __ 7 TFP1S1 PENDENT UPRIGHT CROSS SECTION 1 -Frame 2-Bunon 3-Sealing Assembly 4-Bui> 5 -Compression Screw 6 -Deflector 7 -Bushing FIGURE1 * Temperature rating is inclcaled on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151) AND PENDENT (1Y1251} SPRINKLERS 2.B K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3116' (55,6mm) 1-1/2' (38,1 mm) 1/2' ** NPT 7/16" (11, 1 rrvn) NOMINAL MAKE-IN ' SSP DEFLECTOR* PENDENT 1 • Frame 2 -Button 3-Sealing Assembly 4 • Bui> 5 • Compression Screw STYLE 10 RECESSED ESCUTCHEON 6 • Deflector FIGURE2 ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3116" (55,6mm) t 1/2' NPT** UPRIGHT CROSS SECTION 5 2 3 • Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread comections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251} SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT TFP1111 Page 3 of a ESCUTCHEON PLATE SEATING SURFACE 112• (12,7 mm) NOMINAL MAKE-IN STYLE40 RECESSED ESCUTCHEON ssu• DEFLECTOR 2-5/16" (58,7mm) _l 7 WRENCH FLATS 112· (12,7mm) NOMINAL MAKE-IN 2-1/4" (57,2mm) &* 5 2 3 SSP DEFLECTOR• PENDENT 2-7/8" (73,0 mm) DIA. ---l RECESSED PENDENT 31 .. NPT~ UPRIGHT CROSS SECTION 1 • Frame 2 • Button 1 • Frame 2 • Button 3 -Sealing Assembly 4•Bulb 5 • Compression Screw 6 • Deflector 7 • Ejecllon Spring FIGURE3 * Temperature rating Is indicated on deflector or adjacent 10 orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS B.O K-FACTOR, 314 INCH NPT ESCUTCHEON PLATE SEATING 1/2" ** SURFACE NPT I 2-1/4' (57,2mm) 1-9/16" (39,7mm) 7/16" (11,1 mm) NOMINAL MAKE-IN ' t SSP* DEFLECTOR ssu* DEFLECTOR *6 5 2-3/1 (55,6m 4 2 7 3 PENDENT UPRIGHT CROSS SECTION 3 • Sealing Assembly 4-Bulb 5 • Compression Screw 6 • Deflector FIGURE4 • Temperature rating is intlcated on deflector or aqacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special re(Jlest. • STANDARD RESPONSE SERIES TY-B UPRIGH1' (TY48S1) AND PENDENT (TY4951) SPRINKLERS B.O K-FACTOR, 1/2 INCH NPT Page 4of 8 TFP151 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME WHITE-LEAD WAX WAXOVER LIQUID BRASS PLATED OLYESTER COATED COATED LEADCOATED 135"F/57"C Orange PENDENT 155"F/68"C Red 2.8 (TY1251) 1,2, 3 NIA 1/2" and 175°F/79"C Yenow NPT UPRIGHT 200°F/93"C Green (TY1151} 286°F/141°C Blue 360"F/182"C Mauve 1, 2 135°F/57"C Orange PENDENT 155"F/68"C Red (TY3251) 1,2,3,4,5,6, 7 1,2, 3, 5 1, 2, 3,5 1,2, 3,5 and 175°F/79"C YeRow UPRIGHT 200°F/93"C Green 5.6 (TY3151) 286"F/141"C Blue 1 •• /2 ... , 3**, 5•• 1"1 2**1 3••. 5•• 1/2" NPT 360"F/182°C Mauve NIA 135°F/57"C Orange RECESSED 155"F/68"C Red PENDENT 1, 2, 3,4, 5 1,2,4,5 NIA (TY3251)· 175°Fll9°C Yellow Flgure4 200°F/93°C Green 135"F/57"C Orange PENDENT 155"F/68"C Red (TY4251) 1,2,5 1,2, 3,5 1,2, 5 and 175"F/79"C Yellow 1,2,3,4,5,6,7 8.0 UPRIGHT 200°F/93°C Green 3/4" (TY4151) 286°F/141°C Blue 1·· :2**, 3••. 5•• 1··. 2**, 5** NPT 360"F/182"C Mauve NIA 135"F/57"C Orange RECESSED 155°F/68"C Red PENDENT 1,2,3,4,5 NIA (TY4251)" 175°F/79°C Yellow Figures 200"F/93"C Green 135"F/57"C Orange PENDENT 155°F/68"C Red 8.0 (TY4951) 1/2" and 175"F/79"C Yellow 1, 2,3, 5 NIA NPT UPRIGHT 200"F/93"C Green (TY4851) 286"F/141"C Blue 360"F/182"C Mauve NOTES: 1. Usted by Underwriters Laboratories, Inc. (UL). 2. Usted by Underwriters Laboratories, Inc. for use In Canada (C-UL). 3. Approved by Factory Mutual Researoh Corporation (FM}. 4. Approved by Iha Los8 Prew,nlion Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City cf New 'tbrk lfflder MEA 354-01-E. 8. VdS Approved (For detals 00ntact 1yco Fire & Buldlng Products, Enachede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by Iha Losa Prevention Certification Board (LPCB Ref. No. 0948/05). 8. Where Polyester Coated, Lead Coated. wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Usted, the sprinklers are UL and C-UL Listed as Corrosion Resislant Sprinklers. Yt'hera Lead Coated, wax Coated, and wax over Lead Coated Sprinklers are noted ID be FM Approved, Iha sprlnklers are FM Approved as Corrosion Resistant Sprlnldera. • Installed wfth Style 10 (112" NPT) or Style 40 (3/4" NPT) 3/.t" T0181 Adjustment Recessed Eecutcheon, as applcable. •• 150°F/66°C Maximum Celling Temperature . ... Frame and deflector only. Ustlnga and approvals apply to color (Special Order). N/A; Not Available TABLE A LABORATORY USTINGS AND APPROVALS TFP1S1 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. ;l (73,0mm) 2-1/4" DIA. 7 <s1.2 mm> r I 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" ....._ _______ .J.•'\1-' .. -'""""-. ..,,&-'""--rn --~ .... l--Ui--~~= =r CLOSURE FIGURES 1-1/4' (31,8 mm) 3/4" (19, 1 mm) SERIES TY-B RECESSED PENDENr SPRINKLER ASSEMBLY WITH TWo-PIECE 3/4 INCH TOTAL ADJUSTIIENT STYLE 10 RECESSED ESCUTCHEON 518:t:1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 5.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. =;l (73,0mm) 2-1/4" DIA. --1 (57,2 mm) _j I 3/4" 19,1 mm 1/4' (6,4 mm) MOUNTING PLATE 1/8' (3,2 mm) ......___ ~~;::::;I l--ll1~E: j_ CLOSURE SERIES TY-B RGUREB 1-5/16' 33,3 mm) 13./16" (20,6 mm) SERIES TY-B RECESSED PENDENT SPRINKLER ASSEIIIBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON B.O K-FACTOR, 314 INCH NPT PageSof 8 WRENCH RECESS (END "A' USED FOR 1/2"' NPT MODELS) WRENCH RECESS (END 'B" USED FOR 314" NPT MODELS) RGURE7 W-TYPE 8 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURES W-TYPE 7 RECESSED SPRINKLER WRENCH Page8of8 Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete approval Information including corrosion resis- tant status.) Maximum Working Prenure 175 psi (12,1 bar) Discharge Coefficient K "' 2.8 GPM/psi112 (40,3 LPMJbar112) K = 5.6 GPM/psi112 (80,6 LPMJbar112) K = 8.0 GPM/psl112 (115,2 LPMJbar112) Temperature Ratings Refer to Table A Flnlahu Sprinkler: Reessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Phyelcal Characteristic• Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . . . . . . Beryllium Nickel w/feflont Bulb ............... Glass Compression Screw . . . . . Bronze Deflector . . . . .. . . . . . Copper Bushing (K=2.8) . . . . . . . Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Serles TY-B Pendent and Upright Sprinklers are Intended for fire protec- tion systems designed in accordanoe with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 1 O or 40 Recessed Escutcheon, as applicable, Is to be used for recessed pendent installations. Installation The Series TY-B Sprinklers must be Installed in accordance with the follow- ing Instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble fs approximately 1/16 Inch (1,6 mm) for the 135°F/57"C to 3/32 inch (2,4 mm) for the 360"F/182"C temperature ratings. A leak tight 1/2 Inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxf.. mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 314 Inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. {13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 314 NPT con- nections. Higher levels of torque may distort the sprinkler Inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Serles TY-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be Installed ln the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler Into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Raf. Fi9ure 7), except that an 8 or 10 inch adJustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable Is to be applied to the wrench flats. When Installing wax coated sprinklers wfth the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- TFP1S1 Ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal Is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the WBK coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. "attempts to retouch the wax coating with complete coverage are unsuc• cessfrJI, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously cJe.. scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-haH inch away from the area re- quiring retouching. The wax w,71 melt and run down onto the sprinkler. The series TY-B ReceUed Pandent Sprlnklera must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate. as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figu~ 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- TFP151 stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. C&reand Maintenance The Serles TY-B Sprinklers must be maintained and serviced in accord- ance with the following Instructions: NOTES Before closing a fire protection system main control valve tor maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may bs affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustioo, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, s~rlklng, wrench twist/slppage. or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made. so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the In- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g.. NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Page 7 of 8 Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects In material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (1 0) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes. nor authorizes any person to assume for It, any other obfigation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives. ~~8~~NiEs~~'m.r,'JiS> tffl.r- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL lHE- ORV, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE EQREOQING WARRANTY IS UAQE IN LIEU OE ANY AND ALL OTHER WARRANTIES EXPRESS QB ffllPLIEQ, INCLUDING WARRANTlES OE MERCHANTABILITY ANO EU-NESS EQB A PARTICULAR PUB- ~ TFP151 P/N 57-XXX-X-XXX I I I MODElJSIN I SPRINKLER TEMPERATURE RATING 530 2.81< UPRIGHT (1/2"NPT) TY1151 NATURAL BRASS 135 135°F/57°C 531 2.81< PENDENT (1fl"NPT) TY1251 4 WHITE POL VESTER 155 155°F/68°C 570 5.6K UPRIGHT (1/2"NPT) TY3151 571 5.6K PENDENT (1fl"NPT) TY3251 590 8.0K UPRIGHT (3/4"NPT) TY4151 591 8.0K PENDENT (3/4"NPT) TY4251 560 8.0K UPRIGHT (1/2"NPT) TY4851 561 8.0K PENDENT (1fl"NPT) TY4951 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED 6 WAXCOATED 286°F/141°CMAX. 8 WAX OVER LEAD 286°F/141°C MAX. TABLEB PARTNUIIBERSELECTION 175 175°F/79°C 200 200°Fl93°C 286 286°F/141°C 360 360°F/182°C • Eastern Hemisphere sales only. SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Anemblles wllll NPT Thl'Nd Connections: Specify: (Specify MocteVSIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Serles TY-8 (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table B). ReceaNd Eacuteheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), PIN (specify). 1/2' (15 mm) Style 10 Chrome Platad. . . . . . . . . PIN 58-701-9-010 1/2" (15 mm) Style 10 WhleColor Coated . . . .. .. .. . . . .. . PIN 58-701-4-010 112" (15 mm) Style 10 White RAL9010-. . . . . . . PIN 56-701·3-010 1/2" (15 mm) Style 10 Br888 Plated........... PIN 58-701-2-010 314" (20 mm) Style 40 Chrome Plated. . . . . . . . . PIN 58-700-9-010 314• (20 mm) Style 40 WhftaColor Coaled . . . . . . .. . . . . . . . PIN 58-700-+010 3/4' (20 mm) Style 40 White RAl.9010* .. .. .. . PIN 58-700-3-010 314" (20mm) Style 40 Brus Plated........... PIN 58-700-2--010 • Eastam Hemisphere sales only. Sprlnlder Wrench: Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, PIN 56-850-4-001. Wax Sticks: (for retouching wrench damaged wucoallng) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- rles TY-8 Sprinklers, PIN (specify). Black for 135•F ............ PIN ~1-135 Rad for 15ff ............. PIN ~1-155 Yellow for 175"F......... PIN 58-G65-1-175 Blue for 200"F and 288"F . . . . . . . . . . . . . . . . . PIN 56-065-1-286 NOTES Each wax stick is suitable for retouch- Ing up to twenty-five sprinklers. The wax ustld for 2B6°F sprinklers Is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200"F sprinkler (I.e., 150°F). TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 1:qca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC-8 -8.0 K-factor Extended Coverage (Light HazardJ Customer Servi Tel: (414) 570-5000 / 00) 558-5236 Fax: (414) 570-5010/ 800) 877-1295 Pendent and Recessed Pendent Sprinklers General Description The Series EC-8 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules {e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprin- klers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon pro- vides up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent po- sition, whereas, the Style 40 provides 3/4 inch (19, 1 mm) of vertical adjust- ment from the flush pendent position. The adjustment provided by the Re- cessed Escutcheons reduces the ac- curacy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resls- IMPORTANT Always refer to Technical Data Sheet TFPlOO for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or fts compo• nents and cause the sprinkler to faff to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing Is not representative of all possible cor- rosive atmospheres. Consequently, it Is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-8 Extended Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Fal#ure to do so may Impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY4232 -Pendent, 8.0K TY4232 is a redesignation for C4232. JANUARY, 2005 Technic Data Approvals UL and C-UL Listed. M and NYC Ap- proved. (Refer to Tab e A for complete approval information including corro- sion resistant statu . The approvals apply to the service conditions indi- cated in the Design riterla section.) Maximum Working ressure 175 psi (12, 1 bar) Pipe Thread Conne tlon 3/4 inch NPT Discharge Coefflcle ts K = 8.0 GPM/psi1/2 (115,2 LPM/bar112) TFP223 Page 2 of 6 Components: 1 • Frame 2 • Button 3 • Sealing Assembly 4·Bulb 2 5 • Compression Screw 3--malbNlll,,l..ll, 6 • Deflector * * Temperature rating is 4 lndiceted on Delleclor. ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE1 1-7/16" (36,5mm) TFP223 SERIES EC-B (TY4232) EXTENDED COVERAGE PENDENT SPRINKLERS SPRINKLER FINI HAZARD TYPE TEMP. BULB NATURAL WHITE" LIQUID BRASS POLYESTER LIGHT PENDENT 135°F/57°C Orange 155°F/68"C Red 1, 2, 3 5 Refer to Table B for UL and C-UL Sen&ltlvHy Rating REC. PENDENT 135°F/57°C Orange and w/ Style 30 Esc. 155°F/68°C Red 1, 2, 3 5 Refer to Tabla C for FM Sensitivity Rating REC.PENDENT 135"F/57°C Orange w/ Style 40 Esc. 155°F/68°C Red 1, 2, NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Where Polyester Coated Sprinklers are noted to be UL and C-UL Usted, the sprinklers are UL and CUL Listed as rrosion Resistant Sprinklers. 5. Approved by the City of New York under MEA 113-04-E. *Frame and Deflector only. Listings and approvals apply to color (Special Order). Temperature Ratings 135"F/57°C and 155°F/68°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . . . . . Bronze Sealing Assembly . . . . . . . . . . . . . . . Beryllium Nickel w/Teflont Bulb . . . . . . . . Glass (3 mm dia.) Compression Screw . . . . . . . ................ Bronze Deflector . . . . . . . . . . . . Brass t Registered trademark of DuPont TABLE A LABORATORYUSnNGSANDAPPROVALS (Refer to the Design Criteria Section) Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluld expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The Series EC-8 Extended Coverage Pendent Sprinklers must only be in- stalled in accordance with the applica- ble UL and C-UL Listing or FM Ap- proval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installatio , as applicable (Ref. Table A, B, and ). UL and C-UL Llstln Requirements 1. The Series EC-8 prinklers may be used for the cove ge areas shown in Table D, based n maintaining the minimum specifl flow rate as a function of covera e area and haz- ard group for all the sprinklers in the design area. 2. With respect to h at sensitivity, the Series EC-8 Sprin lers can be used with unobstructed onstruction con- sisting of flat, s oth ceilings (in- cluding bar joists) with a maximum pitch of one in si as defined and permitted by NFP 13. 3. The minimum allo able spacing be- TFP223 Page 3 of 6 AREA STYLE 16x 16 Pendent 16x 16 Style 30 Recessed 16 X 16 Style 40 Recessed 18 X 18 Pendent 18x 18 Style 30 Recessed 18 X 18 Style 40 Recessed 20x20 Pendent 20x20 Style 30 Recessed 20x20 Style 40 Recessed QR: Quick Response SR: Standard Response N/A: Not AppHcable 135°F 155°F QR QR QR QR QR QR QR OR OR SR OR SR OR SR OR SR SR SR TABLES SENSmvTTY RA TING FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 135°F 155°F AREA STYLE 16 X 16 Pendent OR OR 16 X 16 Style 30 Recessed QR NIA 16 X 16 Style 40 Recessed NIA NIA 18 X 18 Pendent OR OR 18 X 18 Style 30 Recessed OR NIA 18 X 18 Style 30 Recessed NIA NIA 20x20 Pendent QR QR 20x20 Style 30 Recessed OR NIA 20x20 Style 40 Recessed NIA NIA OR: Quick Response SR: Standard Response NIA: Not Applicable TABLEC SENSITIVITY RA TING FOR FM APPROVAL OF SERIES EC-S SPRINKLERS tween the Series EC-8 Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). 4. The Series EC-8 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for ex- tended coverage pendent sprin- klers. FM Approval Requirements The Series EC-8 Extended Coverage Sprinklers are to be installed in ac- cordance with the applicable Factory Mutual Loss Prevention Data Sheet. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spacing, and deflector-to ceiling distance. lnstallat The Series EC-8 Sp lnklers must be installed in accordan with the follow- ing instructions: NO Do not Install any bul type sprinkler if the bulb is cracked o there is a loss of I/quid from the bulb. lh the sprinkler held horizontally, a mall air bubble should be present. T, diameter of lhe air bubble Is approxi ately 1/16 Inch {1,6mm). A leak tight 314 inch T sprinkler joint should be obtained th a torque of 10 ID 20 ft.lbs. (13,4 ID 2 ,8 Nm). A maxi- mum of 30 ft.lbs. (40 7 Nm) of torque is to be us&d to I tall sprinklers. Higher levels of torq may distort the sprinkler inlet with equ&nt leak- age or impairment of he sprinkler. Do not attempt to co ipensate for in- sufficient adjustment fan Escutcheon Plate by under-or o r-tightening the Sprinkler. Readjust t 9 position of the sprinkler fitting to sui . Step 1. The sprinkler ust be installed with the deflector pai llel to the mount- ing surface. Pendent sprinklers must be installed in the pe dent position. Step 2. After installin the Style 30 or 40 mounting plate ( other escutch- eon, as applicable) er the sprlnkler pipe threads, and ith pipe thread sealant applied to t e pipe threads, hand tighten the s rinkler into the sprinkler fitting. Step 3. Wrench tight n pendent sprin- klers using only the -Type 3 (End A) Sprinkler Wrench. W ench tighten the recessed pendent prinklers using only the W-Type 4 S rlnkler Wrench. The wrench recess f the applicable sprinkler wrench (Re . Figure 4 and 5) is to be applied to the prlnkler wrench flats (Ref. Figure 1). Page 4 of 6 DESCRIPTION TV4232 (K:8.0) PENDENT 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpmlft2 = 40.74 mm/min AREA 16x 16 18x 18 20x20 TABLED GPM PSI 26 10.6 33 17.0 40 25.0 FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 1/2:t118" (12,7:t3,2 mm) FACE OF SPRINKLER FITTING \ 2-7/8" DIA. (73,0mm) 2-1/4" DIA. (57.2mm) 1/2" 12,7mm 1/4' (6,4 mm) 1-1/4' (31,8 mm) 1"(25,4mm) FIGURE2 SERIES EC-S RECESSED PENDENT SPRINKLER ASSEMBLY WITH TW~IECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 9/16:t1/4" (14,3:t6,4 mm) FACE OF SPRINKLER FITTING f \ MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0mm) 3/4" (19, 1 mm) 2-1/4' DIA. 1/4' (6,4 mm) (57,2mm) 1/8' (3,2 mm) j 1-5116" (33,3 mm) 13/16' (20,6 mm) FIGURE3 SERIES EC-S RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON TFP223 "FITTI E" TOWARD KLER Care an Mainten The Series EC-8 Sp inklers must be maintained and ser Iced In accord- ance with the followin instructions: NO Before closing a fire main control valve r mafntenanca work on the fire pro tlon system that it controls, permissl n to shut down the affected fire pri ection systems must be obtained om the proper authorities and all pe nnel who may be affected by this a lion must be no- tified. Sprinklers that are fo nd to be leaking or exhibiting visible s ns of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coat d, or otherwise altered after leaving e factory. Modi- fied sprinklers mu t be replaced. Sprinklers that have een exposed to -------······ •••• TFP223 corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual Inspections per NFPA 25 should suffice; however, Instead of in- specting from the floor level, a random sampling of close-up visual Inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices In compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA .25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It Is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (1 O) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty Is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, main1ained, modified or repaired In ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete Information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE EQREOQING WARRANTY /S MAQE IN LIEU QF ANY AND ALL OTHER WARRANT/ES EXPRESS OB /MPL,IEQ INCLUDING WARRANTIES QE MERCHANTABILITY AND EU· NESS FOR A PARTICULAR PllB· J!QSE.. Page 5 of 6 Ordering Procedu e When placing an orde , Indicate the full product name. Pie se specify the Sprinkler ldentlflcatio Number (SIN), quantity, and tempera ure rating. Refer to the Price List for c mplete listing of Part Numbers. Contact your local di ributor for avail- ability. Sprinkler Assemblle with NPT Thread Connection Specify:TY4232, (s lfytemperature rating), Extended C era~e Pendent Sprinkler with (spe lfy finish), P/N (specify). 135'Ffli7"C Natural Brass ............. PSN 50-801-1-135 White Coated ............ PSN 50-801-4-135 White (RAL9010)* ......... PSN 50·801-3-135 Chroma Plated . . . . . . . . . . . PSN 50-801-9·135 155'F/68"C Natural Brass .......... , .. PSN 50-801-1-155 While Coated ............ PSN 50-801-4-155 White (RAL9010)' ......... PSN 50-801-3-155 Chrome Plated ........... PSN 50-801·9-155 'Eastern Hemisphere s es only. Recessed Escutche n: Specify: Style (30 o 40) Recessed Escutcheon with (sp cify finish), PIN (specify). Style 30 Racnaad Eaculc eon Chrome Plated ............ PSN 56-705-9-011 White Color Coated ........ PSN 56-705-4-011 White (RAL9010)' .......... PSN 56-705-3-011 Brass Plated . . . . . . . . . . . . . PSN 56-705-2-011 Style 40 RacHaad EIICUI eon Chroma Plated ............ PSN 56-700-9-010 White Color Coated ........ PSN 56-700-4•010 White (RAL9010)' ......... PSN 56·700-3-010 Braas Plated .............. PSN 56-700-2-010 *Eastern Hemisphere s es only. Sprinkler Wrench: Specify: W-Type 3 S rinkler Wrench, P/N 56-895-1-001 Specify: W-Type 4 R essed Sprinkler Wrench, P/N 56-875--001 Page 6 of 6 TFP223 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pemsylvanla 19446 46 INCORPORATED COftONA, CA• 1909) 737.5599 FIG. 68 WIDE THROAT TOP BEAM "C" CLAMP WITH LOCKNUT Size Range -3/8 thru 7 /8 inch rod. Function -For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals -Conforms to Manufacturers Stand- ardization Society SP-69, type 19. Finish -Plain and Electro-Galvanized. Order By -Figure number, rod size, and finish. Note -Do not overtighten set screw. FIG. 69 BEAM CLAMP RETAINING STRAP Size Range -3/8 thru inch length. Material -Carbon Steel Function -To offer more secure fastening of beam clamp to beam when danger of movement might be expected. Approvals -Underwriters' Laboratories listed when used with Tolco U.L. Listed Fig. 65 and 66 Universal Beam Clamp. Finish -Mil. Galvanized and Stainless Steel. Order By -Figure number, type, length "A", and rod size being used with beam clamp, Note -Minimum return on Strap: 1". TYPE 1 2 3 . : ; I 10 ROD SIZE HOLE SIZE 7/16 ·. :.9/16, . 5/8 11/16 • . : 3/4i-. < ••.· , 13/16 A I STOCK SIZE A FINISH 16gaxl t Mil. Galv. l~~"~,-.,:.:;li;d[l)ttfi~;7lif;iMifl~~Wl{i:}:.,, 14gaxl-l/4 i Mil. Galv. l~~liJ/4t~;i(.({!::~'fJlt}Mltiiii~k'.{Ji1; 3/8 -7/8 specify 12gaxl-l/4 t Mil. Galv. INCORPORATED CORONA, CA • (909) 737-5599 45 FIG. 65 AND FIG. 66 REVERSIBLE C-TYPE BEAM CLAMPS -3/4" AND 1-1/4" THROAT OPENINGS FIG.~ Size Range -(Fig. 65) 3/8 thru 5/8 inch rod (1/2 thru 10 Inch pipe). Size Range -(Fig. 66) 3/8 thru 5/8 inch rod (1/2 thru 10 inch pipe). Material -Carbon Steel with hardened cup point set screw and jam nut. Function -Recommended for hanging from steel beam where flange thickness does not exceed 3/ 4" (Fig. 65) or 1-1/4" (Fig. 66). Features -All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engage- ment. Application Note -Fig. 65: add l-l/2H to rod length when clamp is to be used in set screw up position. Fig. 66: add 2" to rod length when clamp is to be used in set screw up position. Approvals -Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 23, and Manufacturers Standardization Society SP-69, type 19 and 23. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet #13, 3/8" rod will support 1/2 thru 4" pipe, 1/2" rod will support 1/2 thru 8" pipe. Finish -Plain, Electro-Galvanized, HDG, and Stainless Steel. Order By -Figure number, rod size, and finish. B --l ' ---f'1--A : ': FIG. 66 ROD SIZE A C L PIPE SIZE B I I I \ I I I I I -r "! LJ FIG. 65 TABLE MAX. APPROX. REC. WEIGHT C D E F LOAD LBS. PER 100 3/8 1/2 -4 1 -3/16 3/4 1 7 /16 1 1500 28 112.--.• 5.:~a:. ·:J,~J/2 • .. , 3/4; ;:;:;4:.,:,,:,zffi~~t:Jt$;tli~f.~itAA~0::T:Wlii;Ni1 5/8 10 1 -1/2 3/4 1 9/16 1 -1/4 FIG. 66 TABLE ROD MAX. APPROX. SIZE PIPE REC. WEIGHT A SIZE B C D e· F LOAD LBS. PER 100 3/8 1/2-4 1 -3/16 1-1/4 1 7/16 1 1500 32 112 • •. • ·fr~ 8·, ;ci• ;;· 11z : . .1:~ :i/4)rt:'{~t{L'6!ti1ittf4,:foyf 4060}IA_i,,:.tti1 f:, 5/8 10 1 -1/2 1 -1/4 1 9/16 1 -1/4 120 INCORPORATED COAOHA. CA• (909) 737.5599 FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range • Pipe size to be braced: 1" through 8" Sch. 10 and 40. Pipe size used for bracing: 1" and 1-1/4" Sch. 40 IPS. Material • Carbon Steel Function • For bracing pipe against sway and seismic disturbance. The pipe attachment com- ponent of a sway brace system: Fig, 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe per NFPA #13*, forming a complete sway brace assembly. Features -Can be used to brace Schedules 10 and 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting -type sway brace fittings. Comes individually packaged with illustrated installation instructions • sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector that necessary minimum torque (5 lb/ft) has been achieved. Application Note • Fast Clamp need not be field assembled. Position Fast Clamp and· tighten two hex nuts until leaf spring flattens. *Length of bracing pipe per National Fire Protection Association, Pamphlet #13, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7'-2". 1-1/4" Schedule 40 bracing pipe maximum 9'-2". Approuals • Underwriters' Laboratories listed. Note • Must be used· with T oleo U .L. Listed 900 Series attachment. Finish • Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By • Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. a ,--- 1 ~-------] ------ ----.. I i I ,< I I I ! ____ ,,_,' Schedule-10.,/Schedule-40., Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-I 0/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 ( 11~ "-811) pipe and Sch-40 (l "-21/2 ") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-! O/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating Our advanced formula mi II coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset ofMicrobiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test NPS ln;mm 1' 25 1¼' 32 1½' 40 2' 50 2½' 65 NPS ln;mm 1" 25 1¼" 32 1½' 40 2· 50 2½" 65 3' 80 4' 90 5" 125 6' 150 8' 200 'fi/CO I Row Control Q allied TUBE& CONDUIT Sch-40 Specifications Nomlnal I.D. WI. Wt. (K20 filled) Pcs/ Wt,1.ill (21') WI/Lilt (24') WI/Lilt (25' ln;mm Lbs/Ft; Kglm Lbs/Ft; Kglm Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 2,940 26.6 2.5 3.05 70 1,120 1,280 1,334 1.380 2.270 2.93 51 2,43i 2,778 2,894 35.1 4.36 4.36 51 1,103 1,260 1,313 1.610 2.720 3.61 44 2,513 2,872 2,992 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 52.5 5.4 7.63 30 1,043 1,192 1,242 2.469 5.790 7.86 19 2,310 2,640 2,750 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch•10 Specifications Nominal I.D. Wt. WI. (H20 Filled) Pcs/ Wt/Lill (21 ') Wt/I.ill (24 ') WI/Lill (25', ln;mm Lbs/Ft; Kglm Lbs/Ft; Kglm Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 21.9 2.1 2.10 91 1,213 1,385 1,445 1.442 1.810 2.52 61 2,319 2,664 2,760 36.6 2.7 3.15 61 1,052 1,208 1.252 1.682 2.080 3.04 61 2,664 3,045 3,172 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 54.8 3.9 6.28 37 930 1,063 1,108 2.635 3.530 5.89 30 2,224 2,542 2,648 66.9 5.3 8.71 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 108.2 8.3 17,53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 161.5 13.8 34.27 10 885 1,012 1,053 8.249 16.490 40.15 7 2,424 2,770 2,885 209.5 24.5 59.75 7 1,100 1,256 1,309 ®<8>@ Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 11350 Norcom Rd.• Ph0adelphia, PA 19154 2525 N. 27th Ave. • Phoenix, /!\l. 85009 Customer Service: {800) 882-5543 Fax 708-339-1806 l_ S5-3 Brecco Corporation L FOR USE WITH WET OR DRY SYSTEMS. GAUGES HAVE A BRONZE BURSON TUBE MOVEMENT IN A STAINLESS STEEL PlA TED CASE (UNLESS OTHERW•se NOTED). 3--1/2" DIAMETER. U.L. AND F.M. APPROVED (UNLESS OTHERWISE NOTED). •.,•1, :, ' •• . • :;•,, •· ' • 1 ' I ' •, , • .. ,i • • ~,. ~ • • • I '. '. ~• 0 I ' ' • r~ • ~ t ' : • ,.'. _,\ • .,: ' ------ ,,. I '1 . , ..... • • 1'~aoot543~41194 AR• = AS REQUIRED GAUGES Pa,tNo. GAAWSS350 GAASS2SO GAWP200 GMWP350 '' . ' ' ► OAUGBS < Deacnplion Bo1ICase Qtv MR/WATER 0-300 PSI 80 WI STAINLESS STEEL CASE AIR WI RETARD 250 PSI ~112" DIA. WI STAINLESS STEEL 80 CASE 2" RESIDENTIAL GAUGE 300 PSI 100 (NOTU.L. OR F.M. APPROVED) AIR/WATER WI PLASTIC CASE 60 .---... , ',, ....... , ....... . l'aa: 1-877-474-9248 bleccocorp@eartt,fink.~f 082000 .,.-_-..,,. INCORPORATED CORONA, CA• (909)737-5599 30 FIG.909 NO,THREADSWlffLSWAYBRACEAITACHMENT Size &nge-1 and 1-1/4 inch bracing pipe. For brace pipe sizes larger than 1-1/ 4 inch use T oleo Fig. 980. Material -Carbon Steel, hardened cone point engaging screw. Function -The structural component of a sway and seismic bracing system. Features- • No threading of the bracing pipe is required. • Open design allows for easy inspection of pipe engagement. • All steel construction eliminates deficiencies associated with malleable type attachments. • Fastener can be mounted to all surface angles. Application Note • The Fig. 909 is used in conjunction with the Talco Fig. 1000 "Fast Clamp™", Fig. 2001, or Fig. 4(A} pipe clamp, and joined together with bracing pipe. Install per NFPA # 13 and/ or T oleo 's State of California OSHPD Approved Seismic Restraint Manual. Installation -Extend bracing pipe through opening. Tighten cone point engaging screw until head bottoms out. Approvals -Underwriters Laboratories Listed per 203A (UL). Approved by State of California Office of Statewide Health, Planning and Development (OSHPD). Finish -Plain, Electro Galvanized and HOG. Order By-Figure number, pipe size and finish. Important Note -The Fig. 909 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure oerfortnJU1ce, the UL Listingrequires that the Fig. 909 must be used only with other To/co bracingproducts. NATIONAL AND INfERNATIONAL PATENT APPLICATIONS IN PROCESS. MAX. MAX. PIPE SIZE A B H• HORIWNfAL DESIGN LOAD LBS. HORIZONTAL DESIGN LOADl,BS. W/WASHER APPROX. Wf./100 1 6 1-5/8 17/32 2015 2765 1-1/4 6 1-5/8 17/32 2015 2765 • Available with hole sizesio accommodate up to 3/4" fastener. Consult Factory 91 97 0 ® State of California OSHPD APPROVED " St.andard washer (F1g. I 15) required for 2765 lb. design load INCORPORATED COflONA. CA• (908) 737.5599 FIG. 4 STANDARD PIPE CLAMP Size Range -1/2 thru 30 inch pipe. Material -Carbon Steel Function -To carry piping where little or no insulation is required. For heavier loads, see Fig. 4H. Approvals -Listed by Underwriters' Laboratories 2 -8 inch (1/2 -1-1/2 inch listed if E.G.). Approved by Factory Mutual Engineering, 1/2 -8 inch. Federal Specification WW-H-171E, type 4, 1-1/2 thru 24 inch and Manufacturers Standardization Society SP-69, type 4. Maximum Temperature -750°F Finish -Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By -Figure number, pipe size, and finish. 20 28 1-3/8 3-5/16 5/8x2-l/2 1-1/8 19 MAX. REC, LOAD US. APPROX. FOR SERVJCE TEMP. WEIGtrr &SrF 750°F PER 100 500 445 29 1040 930 3060 2730 FIG. 51 INCORPORATEO CORONA. CA • (908) 737-5599 FIG. 51 AND FIG. 52 SIDE BEAM BRACKETS (CONT.) A I FIG. 52 FIG. 51 for NFPA Rod and Fastener Sizing APPROX. PIPE ROD HOLE SIZE STOCK WEIGHT SIZE SIZE A B C H-1 H-2 SIZE PER 100 1/2 -2 3/8 2 3/4 2 7/16 7/16 3/16x2 35 2~itf ;:i.;Jh~t:...;~i~~~1:::i•;;;~;;.:~!D)J; ,_j,~;,-~/24,i;,c::.:,,\/'. ·<:t· :c:,1:.:.~;.l ::}/lJ{i\,i,:>',;_~;v_i,~_L,;,;,~.;;;~ . '.. -;·; .-.\~t.i~.~.r'.t~,i.,::iiii.;~i,:il:i~,.;.§f~,:i,,,;a,~ 5-6 1/2 2-1/2 3/4 2-1/2 9/16 9/16 3/8x2-1/2x2-l/2 71 • ;;r:;;;~:\:?}::,,;:,.~:(Ug\~t:a~g;:i(~::::,>'k"3/~:,,'"t,;~:·;;,g,J/g-: .=,~·-. • ,:.:ivw~·, ':9/:l:6, ;:.:-::..,,,~ ~/~~~M~~;l/~i:'/'"::,-:\•.;·JQ;':~.,~·:,;~,\:~ FIG. 52 • 6 Hole Bracket ROD SIZE 3/8xl/2 A 2 B 1-1/16 HOLE SIZE C H-J H-2 H-3 2 9/16 7/16 9/32 FIG. 56 STOCK SIZE 3/16x2 APPROX. WEIGHT PER 100 35 TAPPED SIDE BEAM CONNECTOR Size Range -1/2 thru 4 inch pipe (3/8 inch rod). Material • Carbon Steel Function -Practical and economical bracket used Lo support hangers from steel or wood beams. Can be used with concrete shot-type inserts. Tapped hole allows easy adjustment of hanger rod. Approvals• Underwriters' Laboratories listed and Factory Mutual Engineering approved for 1/2 -4N pipe. Finish -Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By -Figure number and finish. Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8 inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch fastener. PIPE SIZE ROD SIZE A B C D E l/2 • 4 2-5/8 3/8 l 3/8 1-1/16 APPROX. HOLE SIZE STOCK WEIGHT F G H J SIZE PER 100 1-1/8 7/16 9/16 1-1/4 1/4xl 20 41 Submittal Data Sheet Super 40°/Dyna-Thread0 Full Line Sch-40 Replacen1ent Super -1<1/Dyna-Thro?:id sprinkler pipe rept·esem,; on engineering advancemem for 1he sprinkler pip.: im1umy. 11 rombine~ the safe1y and longcviIy or rr:1diIional Sch-40 pipe with qu:1liry and Sllperi<ll' hydraulic :idv:1111ages. Comparison to Schedule 40 Super 40/Dyna-Tlueads inside di:10me.r is up 10 3.6% l;irg.er 1ha11 Sch--tO giving ii superior hydraulics. Also, when used in combination wi1h Dyna-Flow pipe, c.Jown si:z.ing oflen occurs. Super 40/Dyna-Thread is fully listed and approved UL, ULC, :ind FM for lire sprinkler :1pplica1ions. The life e.xpecumcy of Super 40/D.vna-Thread and Sch-40 are e•1ual b;i~ed on 1he calcul:ued wall thicknesses per UL (sec CRR). The consis1em quality of sreel u--~d 10 make Super 40/Dyn:1-Thre:1d fociliwtes smot11h 1hre;1ding und lower mnin1enance costs. Th~ e.,1,:rnir ut' Sup,:r ~ll/Dyn:t-Thre:1d is pro1ec1etl by a cklln, durnble mill coaring for ex,ent.led ,t.dt' life and c:1.,r p:iim ,1pplic:11ion. Wi1h its increaseu s1reng1h and lighter w~ighl, Super40J 0\11a-Thre:1d re.1uc.-s i11s1.1ll.11ion foti~t1e and is iJe:11 for rc1ro-lit applicmions. Corrosion R,.~"~latll'f Ra1io 1CRR1 is :1 UL (Underwriters Ltbomtory} term for the es1iinmed life expet·tnnc)' ut :1 pip,! joim. This Is based on the calculated wall thickness ,11 1he base or cite first exposed rhreud, "~~Ull1c)u lO be 1he \I t'akest point of the pipe leng1h. Super 40/Dyna-Thread .md Sch-40 have the ,an1e c:llcul:ut"d \mil thicknesses at 1his poi111 and are both as~igned 1he sam~ CR R or 1.00. Comparison to L, W. T. Pipe More wall rhickness a1 tht thread (CRR:a I .OD) gil'es Sup~r .U)/DyM-Thread bener life e~pectnncy than ligh1wal1 threadnble pipe joints. Unlike 1iµh1wall 1hr~adahle pipe. Super 40/Dyn;i-Thread ha~ no 1hrtad gauge warning. Super 401 Dvna-Thread is :ipproved for smndard h~nger sp:icmg (15 ft 0.C.J, cnn be used as eanhquake sway 1,?rnc:ing. and is ~afc rouse :1s drops. Super 40/Dyna-Thread is s:1fer 10 weld on 1han ma11y ,.1nc-1:o:11ed ligh1wall 1hread:1ble pipe products. Super 40/Dyn:1-Thre,1d is more widely accepted ihan lighcwall threadable where Sch-40 is specified. Slamp Her9 Sp~ifications & Approvals Super-l0/Dyna-Thre:1d pipe is mnnufocrured 10 mee1: ASTM A 135. Grade A and is in compli:rnce ,1 i1h NFPA-1 J. All sizes of Super 40/Dymi-Thread are r:ued ~t 300 psi working pressure. Super 40/ o,,n.1-Thread is UL and ULC Listed for wet, dry a1id pre-ac1ion sprinkler S)'Stems and FM Approved for u.,e in \\'Cl sys1e111s. Super 40/Dynn-Thread can bi: "hm-dip" _g.111\•anized 10 meet FM requirement Specifications a-lnchu •=Mattie f,n· dry sys1enu. Super 40/Dyna-Thre~d is approveu i'ur all threaded couplings and welded outle1s and is sunable for all roll-groo1•ed, :md plain-end fiuings. cSee lis1ing informniion). Listvd ApPfOYed Us111D Product NPS X 1" * 25 X 1 1/4" *32 X 1 1/2" *40 ?" " - *50 Nominal Wt/Ft Wt/Ft 1.0. H:z.O Filled 1.080 1.330 1.75 27.4 2.0 2.60 1.408 1.870 2.54 35.8 2.8 3.78 1.639 2.290 3.22 41.6 3.4 4.79 2.104 3.050 4.57 53.4 4.5 6.80 Pcs/ Wt/Lift Wt/Lift Wt/Lift Litt 21.' 24' 25' 70 1955 2234 2327 70 887 1013 1056 51 2002 2288 2384 51 908 1038 1081 44 2115 2418 2519 44 959 1097 1143 30 1921 2196 2287 30 871 996 1037 A1neric~n Tube and Pipe was acquired b)• Allied 1\1be and Conduit on February I, I 997. The engineered lightwall and standard wall family or prod11cls alr~ough they hu1·e dill'crenl names arr the same in all respects with regard 10 Slrength, weigh!, bundle rounl, lis!ings and approl'als. For ex:1mple, Dyna-Flow and Super Fla ore 1he same pl'oducl QS are DynQ ThreQd :md Super ~O. XL is m11nuf11clured wi1h Exterior galvnni1ed coaling. BLT Is n1an11£actured with Black lacquer c'oat!ng. ; Project: Sprinkler Contractor: Date: Engineer: Specification Relerence: System Type: Locations: Comments: Grooved IPS Fittings Victaulic fittings are designed specifically for use in grooved piping systems. Victaulic oilers a broad line of fittings in s.izes through 24' (600 mm) in a variety of straight and reducing styles. Most standard fittmgs are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure rotmgs conform to the ratings of Victaulic Style 77 couplings. A1l iittings are supplied with grooves or shoulders to permit last installation without field prepru:at1on. The grooved design permits nexibility for easy alignment. These fittings are not intended for use wjth Victaulic couplings for plain end pipe (refer to page 55 for fittings available for plain end applications). Fittings are provided in various materials including malleable iron. ductile iron. steel or segmentally welded steel dependmg on styles and size. Fittings .are painted orange enamel with galvamzed optionally available, contact Victaulic for details. Pipe Victaulic fittings are designed specifically for use in groo\led piping systems. Fittings are provided grooved or with shoulders conforrnmg to standard steel pipe outside diameters. When connecting wafer or lug-type butte1fly valves directly to Victaulic fittings with 741 or 743 Vic-Flange"' adapters, check disc clearance dimens10ns with I.D. dirnenSJon of fitting. Request 07.01. Alternate Materials Stainless Steel -Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5. 40 and Type 304 opbonally available) tr1 various sizes. Fitting center-to-end dimenSJons will vazy depending upon t}ipe and schedule. Request 17 .04 for details. Aluminum -Grooved end fittings are available in aluminum alloy 356 TB. in sizes from 1 -8' (25 --200 mm). Request 21.03 or contact Victaulic for details. Alternate Styles EndSeal® "ES" Fittings - EndSeal fittings are available in 2 - 12' (50 -300 mm) for use with "ES" grnoved pipe and HP-70ES EndSeal or 1''ire-RTM couplings. "ES" fittings are painted green for easy identification. EndSeal (anj standard) fittings may be easily internally coated (by others) ior severe service requirements. Always specify "ES EndSeal fittings .. when ordering. Request 07.04 tor information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) -11or severe abrasive services, Victaulic fittings may be rubber or utt.>thane lined (by others). Lining may bE· inside diameter/end (abrasion resistance) or wrap-around (corroSion and/or abrasion) machined. • Request 25.03 or contact Victaulic 1 for specific details. Flow Data Friction Resistance Inches/mm Equivalen1 FeeVmeters ol Slraighl Pipe Pipe Inches/mm Equivalenl Feevmell!fs ol Stralghl Pipe The chart expresse.ci the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated frorn the data given. tor example, a 22%0 elbow is approximately one-half the resistance of a 45° elbow. Values of mid-sizes can be interpolated. 14 90" Elbows No. 100 No.10 1½0 Nom. Aclual Sld. Long Size Size Radius Radius 1 1.315 1. 7 -25 33.7 0.~ 2 2.375 3.5 2.5 f,tl 6ll.:'I 11 oa 3:j: 3.000 4.3 -76.1 1.3 - 3 3.500 5.0 3.8 80 8il 9 15 12 4 4.500 6.8 5.0 100 114 3 2 1 1 S 41/, * 4.250 6.4 -1011.D 1 B 5 5.563 8.5 - 12b 'I41.J 2.6 .. S¼f 5.250 8.1 - 1330 25 - 5½:t 5.500 8.5 -13!)7 26 - 6:j: 6.250 9.6 -159.0 2.g ·- # Contacl VIc1au1tc lor dela~s. :j: 0.0. Dimension. 45° Elbows Tees No. 110 No. 11 1¥.!D Sid. Long Radius Radius Branch Run 0.8 -4.2 1.7 I).~ 13 0~ 1.8 1.1 8.5 3.5 ll5 03 2f1o 11 2.1 -· 108 4.3 OT 33 13 2.6 1.6 13.0 5.0 06 05 40 1.5 3.4 2.1 160 6.8 1l) O\l 49 2.1 3.2 -15.3 6.4 09 4i ~o 4.2 -21.0 8.5 L~ -ll4 26 4.1 -20.0 8.1 I Ii ll.:~ ~.5 4.2 -21.0 8.5 , :l -· GA 26 5.0 -· 25.0 10.0 15 76 30 90° Elbows 45° Elbows Tees No.100 No.110 No. 10 mo No. 11 l½D Norn. Actual Sid. Long Sid. Long Size Size Radius Radius Radius Radius Branch Run 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 150 168 3 30 ?3 15 0.9 ,16 30 G"h:j: 6.500 9.6 -5.0 -25.0 10.0 li551 2.9 -1!> '16 :rn 8 8.625 13.0 9.8 6.5 4.0 33.0 1:::.0 ;?(JO ;!19 1 ~o 3.0 -:!.O 12 10 1 40 10 10.750 17.0 12.0 8.3 5.0 41,0 17.0 PSO 2730 52 3; 2.5 1.5 12.5 5.::::! 12 12.750 20.0 14.5 10.0 6.0 50.0 2(►.0 300 3::?3.Q 61 ~4 30 1 R 15.2 61 14 14.000 # 23.0 # 18.0 60.0 17.0 35D 355 6 # 7.0 # !i.5 1113 ~., ,. 16 16.000 It 26.0 H 20.0 70.0 2C-.O •100 40(34 d 7g n l'> 1 2·13 61 18 18.000 # 29.0 II 23.0 80.0 2:: .. 0 45il ~5l0 ii 6.6 ' ;o 24 4 70 20 20.000 It 33.0 It 26.0 90.0 2E-.O ~00 !l08.0 j; 10.1 jj 7.9 27 4 7.S 24 24.000 # 40.0 # 30.0 30.5 34.0 GOO tj100 # 1·1" # 91 93 10A temMMt?:N!DtiWWtttitWDNIPIIO:tiieiQt Style 07 Zero-Flex® Rigid Coupling The unique angle-pad cleSign of Zero-Flex® SLyle 07 adjusts to standard pipe and roU or cut groove tolerances, positively clamping the pipe to resist flexural and torSionnl loads. Wider key section fills more of the groove area. 2 -12" Sizes 14-16" Sizes 18 -24" Sizes Norn. Max. Dimensior,s -Inches/mm Aprx. Si?e Work Press. Wgt. Each lnches/,nm PSl"/kPa X y 2 L.bs./hg 1 750 2.45 4.13 1.88 1.6 .,i, ~1.·:.l ,t?. ,vs -18 ll ~ 1¼ 750 2.60 4.00 1.68 1.6 J_) ~1 I ; ~, ,,ii 1lj? :LU ll ;- 11h 750 2.94 4.8"1 1.88 1.6 l[I ~I 1 ; ~' -.~ ,,,., 41) d:' .. , 2 750 3.19 5.44 1.88 2.3 !10 ~--1"7!i ~n 111 -1:1 lll 2½ 750 3.88 6.13 1.88 2.8 ti!"J ~711 :~ ~,n 1:;ij -lH , 3 3:j: 750 4.25 5.75 1.86 3.6 ~>l;-~ 1l'll 14(; -1: lu 3 750 4.56 6.81 1.88 3.1 uo ~17!) llt.~ 1--, .. , .:Hl 1-1 4 750 5.B1 8.25 2.06 4.8 11Xl ;:J,"!; 1-1-H '.'1(] 52 ~I 2 4¼:I: 750 5.56 7.44 2.06 5.2 :i1-:-:, 1-11 Iii\) !;:~ .'-1 5 750 7.06 9.75 2.06 7.1 1 •:, :il ~·:~ 175-1 .:-1,J ~,.:1 J.~ 5¼:j: 700 6.36 9.18 2.06 7.4 4~1.'h '7-1 ~J.1 ~-, :; ...t. ~).:. 5½:j: 700 6.94 9.42 2.06 7.6 -ltl~:, I ;t; .'30 :)~ _, J 6 700 8.00 10.75 2.06 8.7 ,,,u 4ll~~' ,'.tri :'.-:~ 5~• 3,1 6¼:I: 700 7.85 10.18 2.06 9.2 :U .. '!, l<I!) _:,!-,9 .=t.1 J ~ 6'h:t,. 700 8.00 10.75 2.06 7.2 .Jfil~ ·•o:l i'"~t !>? .L' 8§ 600 10.25 13.50 2.50 14.9 ?(JO ~Ull :-'(ill ,·j,IJ. ,i.:I t\::i 10 § 500 12.86 16.75 2.56 25.0 .::ill Jtj!~) .;:,·: kl\) 6i, 1, J 12 § 400 14.88 18.50 2.56 28.2 .ltkl .'7all ,;;ll ,:·ii 05 1? t! 14 300 16.19 19.75 2.94 32.8 .l:M) .•,)tj!J •ffl !,(1;,1 7& I cl ~l 16 300 18.38 21.75 2.94 41.2 ~llO :1u1fa .. 1,•:-.):i,; ;"!, ,., -P• 18 300 20.69 23.88 3.06 54.2 -1:,0 ;,0li!li !J:Jli ,:i()li 7;1 ,'4 (i 20 300 23.00 27.38 3.06 67.2 :,,~I :1rii~, :-,i)4 ii!b ;,~ :;~ s 24 250 27.13 31.50 3.13 76.2 i~Xl 17~1~• \IB!l Jim 7n J•I 1' :j: 0.0 O1rnen$100. • Refer IO notes oo page 7. § Available IO J.LS. dimension 8 Style 77 Standard Flexible Coupling @ ~ ~ Style 77 couplings are diJsignecl with cross-ribbed construction co provide a strong component for pressure piping systems. Sizes ¾ -12" (20 • 300 mm) are two-piece housings. Sizes 14 -22' (350 -550 mm) are cast in four identical segments, with larger sizes cast in sLx segments. :V. -12• Sizes 14 -22" Sizes 24" Size Nam. Max. Dimensions -Inches/mm Aprx. Si~e Work Press. Wgt. Each Inches/nun PSl'/kPa X y z L.bs.11'g ¾ 1,000 2.13 3.63 1.75 1., y d\XK, ~l.il iv .,.1 ,I !~ 1 1,000 2.38 3.88 1.75 1.3 :1~ ,;900 LiO !kl .1.1 ll(; 1¼ 1,000 2.63 4.63 1.75 2.0 3~' l\\l()() U:" 11fl, 44 11!1 1½ 1,000 3.00 5.00 1.75 2.1 ~i'I .;ut.lo 1,; 1;•:· I.I ·111 2 1,000 3.63 5.63 1.75 2.6 .:}ti ,.ii.., ~l.:1 1.t~ II 1;• 2½ 1,000 4.25 6.25 1.75 3.1 00 l~lOO l(J:< 1:5H -1-"1 1-1 3:j: 1,000 4.31 6.31 1.75 3.6 ,hl()I.) llil l\Jl) 14 ll:, 3 1,000 5.00 7.00 1.75 3.5 tlll ,;~lOO ,.,. 1.\i ~-I 1 li 3½ 1,000 5.63 8.00 1.75 5.6 1)0 ,~lllD 143 _'!\}~i .1.1 ,, ~ 4 1,000 6.38 8.50 2.00 6.6 ilX~ l~~lLlO n~:, .~1 li ~1 :Ju 41/.i:j: 1,000 5.88 8.06 2.06 7.0 ,hklcl M!l -)l,~l ~l.:I ·'· 5 1,000 7.63 10.25 2.00 10.6 -~;) t\illli.l 11)-i !1ill :,1 -IU 51/, :j: 1,000 7.34 9.20 2.06 10.0 690() lfill .!J.:I ~~' -1!, 5½:j: 1,000 7.60 9.44 2.06 11.0 llHOO 1,i:1 ;,.Ji) :>:? ~l 0 6 1,000 9.00 11.50 2.00 11.8 1:,1' (i!llK) :.'~) :~v !~ 1 :1..I 6¼:j: 1,000 8.50 10.38 2.06 13.2 ii~JlJO .;:' H~ .Ji.."'-1 ~~' llll 6l',:j: 1,000 9.19 l"l.50 2.06 13.2 t)OC)(_l ~~i..i .·~}~ ;,r iitl 8§ 800 11.38 14.50 2.38 20.1 ,'ui) ,,.~ :~uu .. 'lli.t~ ,;o ))1 10 § 800 13.50 16.75 2.50 28.3 ':}il ~,~~, :H.J .1:>:, ti-I ,.'n 12§ 800 15.50 19.00 2.50 34,2 .illi.'J ~5.Jf) .l~)--1 IBJ fi.i 1!,:, 14 300 16.63 20.00 2.88 35.6 ~bl) :l}tt!) 4.':I ~ltd ::~ Hi l 15 300 17.88 21.25 2.88 48.8 3-~~ ::tJ13,; -t!>-I .,-Ill ;.::, .'.' I "16 300 19.00 22.38 2.88 51.l .inr :'C,>!> m..i ~,fia .·:; .,. .. , .. ,. 18 300 21.25 24.38 3.13 64.4 .JS() .;oor, ~4tl liHI -,, :'!):> 20 300 23.50 27.50 3.13 91.2 :,oo .':'fh.1:,-!'l!P iiU,S) -·n 41 l 22 300 25.83 30.00 3. 13 9' !1!10 20tfi u.~, ,-t)? i'n 24 250 27.63 31.38 3.13 mxi 172:i -u:--:-~, T /!) :I: 0 0. Oimeno,on. • Reier 10 noles on page 7 § Avail.able to J.I S. di ·-Super Flo·/Dyna-FIOW® ~-.... figh Strength Steel ?ipe·• The original high-strength 1/ghtwall sprinkler pipe with hydraulics superior to Schedule-10. Super Flo/Dyna-Flow pipe is the "original'' high-scrength lightwall sprinkler pipe. Super Flo/Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-IO pipe. Lightweight, easy to cut and easy to handle for installation. Super Flo/Dyna-Flow is a valuable addition to any fire protection system. Superior Hydraulics With an inside diameter of up to 11 % larger than Schedule-40 and up to 7 % larger than Schedule-10, Super Flo/ Dyna-How pipe hydraulics are ex.ceptional. ,,,,... •• ger I.D.s enable Super Flo/Dyna-Flow, \ ...u.d related components, to be down- sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Super Flo/Dyna-Flow Hydraulic Dara Tables." 1~ • Coatings & Fabrication _. Super Flo/Dyna-Flow products are coated with an environmentally approved and :i-pecially formulated modi-tied-acrylic or water-based coating. This durable coating is paimable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No .. .-P.cial process or equipment are needed fabrication and installation. Specilicalions Jt:;Jnohn •=Mm!c Product Nominal Wt/Ft Wt,/Ft NPS I.D. H20 Filled X 1 • 1.191 0.830 1.31 *25 30.3 1 '.) 1.95 X 11/4" 1.536 1.059 1.87 *32 39.0 1.6 2.78 x 11/2" 1.728 1.667 2.71 *40 43.9 2.5 4.03 ?" X-2.203 2.104 3.79 *50 56.0 3.1 5.64 X 21/2" 2.703 2.564 5.10 *65 68.7 3.8 7.59 X 3" 3.314 3.387 7.18 *80 84.2 5.0 10.69 X 4" 4.310 4.473 10.86 *90 109.5 6.7 16.16 X 6" 6.403 7.714 21.70 *150 162.6 11.5 32.29 Specifications & Approvals SuperFlo/Dyna-Flow pipe is manufactured to meet ASTM A- 795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. ®~@ Usted Approved Listed SuperFlo/Dyna-Flow is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, W)', preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Super Flo/Dyna-Flow is now avai1able "hot-dip"galvanized and has been specifically approved by FM for dry systems uses. Pcs/ Wt/Utt Wt/Lift wt/Lift Lift 21' 24' 25' 91 1586 1812 1888 91 719 822 856 61 1356 1550 1615 61 615 703 733 61 2135 2440 2542 61 968 1107 1153 37 1634 1868 1946 37 741 847 883 30 1615 1846 1923 30 733 837 872 19 1351 1544 1608 19 613 700 729 19 1784 2039 2124 19 809 925 963 10 1620 1851 1928 10 735 840 875 Additional Benefits • Lightweight and easy to install, resulting in more e.fficient use of your fre.ight and labor dollars. • Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and.welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. ,f;Jaflied 11JBE & CONDUIT .t ----~ifDCDIIIIWr 16100 s. Lathrop Harvey, IL 60426 11350 Norcom Rd. Philadelphia, PA 19154 2525 N. 27th Ave. Phoenix, AZ 85009 Customer Service: 1·800-797-6210 INCORPORATEO CORONA, CA • {909) 197-6599 I , , ' ' j , ' I c. \ \ ' J • , ~ • • I FIQ. 99 ALL THREAD ROD CUT TO LENGTH Size Range • 3/8 thru 7 /8 inch rod in 1 inch increments. Material -Carbon Steel Maximum Temperature -750°F Finish • Plain, Electro-Galvanized, and Stainless Steel. Order Bv • Figure number, rod diameter, rod length, and finish. FIG. 100 ROD SIZE 3/8 1/2 5/8 3/4 7/8 MAX. REC. LOAD LBS. FOR SERVICE TEMPS. 650"F 750-F 610 540 1130 1010 1810 1610 2710 2420 3770 3360 ALL THREAD ROD FULL LENGTHS Size Range • 1/4 thru 1-1/2 inch rod in 10' -0" lengths. Material• Carbon Steel Maxirin,m Temi,erature -750°F Finish -Plain, Electro-Galvanized, and Stainless Steel. Order By -Figure number, rod diameter, and finish. MAX. REC. LOAD LBS. APPROX. ROD FOR SERVICE TEMPS WEIGHT SIZE 650-F 750"F PER 100 FT. 53 ~NCCr'\POftATl:.tt CORONA, CA• (909) 7'.!7-5599 FIG. 2 ADJUSTABLE RING HANGER 15 FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range • 1/2 thru 6 inch pipe . .Material -Carbon Steel, Mil. Galvanized to G-90 specification. Function -For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approvals -Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature -650°F Finish -Mil. Galvanized and Stainless Steel. Order By -Figure number and pipe size. PIPE SIZE ROD SIZE A B C A STOCK SIZE MAX. REC. LOAD LBS. C APPROX. WEIGHT PER 100 FIG.2 FIG, 2 NFPA -----····--·········--- LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Infonnation Sheet Name: GREYHA WK BUSINESS PARK Date: October 3, 2005 Location: 3250 GREYHA WK CT. Building: ;;;..z~---------------------System No. ROOF Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: L;;;..C_H ___________________ _ Construction: cg! Combustible O Non-Combustible Drawing No. 3OF3 Ceiling Height 25-0 SYSTEM DESIGN NFPA 13: LightHa7.ald Ordinary Hazard Group l 2 3 Extra Hazard 0 NFPA231 0 NFPA231C: Figure: Curve: D Other (Specify) □Specific Ruling _____________ Made By Date Area of Sprinkler Operation Density 3000 System Type .45 ~ Wet D Dry D Deluge D Pre-Action ---------Area Per Sprinkler 100 S.F. MAX. Sprinkler or Nozzle 100 Make TYCO Model ELO 231-B --------- Ft. Hose Allowance GPM: Inside Hose Allowance GPM: Outside Rack S rinkler Allowance 400 Size ¾ K-factor: 11.2 ------------_....;._ ______ --I NIA Tern rature Ratin 286 DEG. CALCULATION SUMMARY GPM Required _l...;5_4...;6 . ...;9_2 ______ PSI Required _4_4...;.3_9 ______ At Base of Riser "C" Factor Used: Overhead 120 Unde ound 150 WATER SUPPLY Water Flow Te§t Pump Data Tank or Reservoir Date& Time 8-3-05 / I :50 PM Rated Capacity Capacity Static PSI 122 AtPSI Elevation Residual PSI 116 Elevation OPMFlowing 1500 Well Elevation 0 Proof Flow OPM Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD FIRE DEPT. COMMC 11111 v STOR Anc Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletiz.ed %Rack Rack D SingleRow D Conventional Pallet D Automatic Storage D Encapsulated D DoubleRow D Slave Pallet 0 Solid Shelving D Non-Encapsulated D Multiple Row □open Flue Spacing In Inches Clearance From Top of Stora&: to Ceiling Longitudinal Transverse Ft. In. Horiz.ontal Barriers Provided greyhawk bldg z .45/3000 roof 250 240 230 220 210 200 190 180 170 160 150 140 130 120 110 100 • I/ • ~v· 90 80 70 60 50 40 30 20 10 / -.. ld,/ ~, ~ V , ....... 0 250 500 ,.I., I,," 750 1000 System Demand .. Sprinkler Demand 80.28 PSI Additional Flows Hose at Source Total Demand 86.67 PSI 1250 1500 @ 1446.92 GPM 500.00 GPM 0.00 GPM @ 1946,92 GPM Hose1 1750 Water FIOW' (GPM) Sigma Dynamics Corporation 7700 Supply / Demand Graph I Margin Pressure 14.38 PSI now 1343.64 GPM I ~ r ·~ ~ I 2000 2250 Water Supply .. Static 109.80 PSI Residual 104,40 PSI Elevation 0,00 PSI @ 1500.00 GPM - - N1.85 2500 ·-----·--·--• -------- SUBMITl'AL SERIAL NO:4144HY1 10-03-2005 PAGE 1 greyhawk bldg z .45/3000 roof FLOW TEST RESULTS Water Supply STATIC 109.80 PSI RESIDUAL 104.40 PSI @ 1500.00 GPM CITY PRESSURE AVAILABLE AT 1946.9 GPM 101.05 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE ---------------- 100 49.40 44.55 11.20 19.46 101 47.31 44.55 11.20 17.84 102 47.16 44.55 11.20 17.73 103 47.11 44.55 11.20 17.70 104 49.48 44.55 11.20 19.52 105 47.38 44.55 11.20 17.90 106 47.23 44.55 11.20 17.78 107 47.19 44.55 11.20 17.75 108 49.76 44.55 11.20 19.74 109 47.66 44.55 11.20 18.11 110 47.50 44.55 11.20 17.99 111 47.46 44.55 11.20 17.96 112 49.00 44.55 11.20 19.14 113 46.54 44.55 11.20 17.27 114 46.39 44.55 11.20 17.16 115 46.35 44.55 11.20 17.13 116 48.42 44.55 11.20 18.69 117 45.62 44.55 11.20 16.59 118 45.47 44.55 11.20 16.48 119 45.43 44.55 11.20 16.45 120 48.14 44.55 11.20 18.47 121 45.07 44.55 11.20 16.19 122 44.92 44.55 11.20 16.09 123 44.88 44.55 11.20 16.06 124 48.06 44.55 11.20 18.42 125 44.81 44.55 11.20 16.01 126 44.66 44.55 11.20 15.90 127 44.62 44.55 11.20 15.87 129 44.74 44.55 11.20 15.95 SUBMITI'AL SERIAL NO:4144HY1 greyhawk bldg z .45/3000 roof SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 130 131 44.59 44.55 44.55 44.55 11.20 11.20 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 5 OUTFLOWS AT 22 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 15.85 15.82 1446.92 GPM 400.00 GPM 100.00 GPM 1946.92 GPM 86.67 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 26 TO 36 20.64 FPS 10-03-2005 PAGE 2 SUBMITI'AL SERIAL NO:4144HY1 10-03-2005 PAGE 3 greyhawk bldg z .45/3000 roof Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 127 131 2.703 L 9.00 C=120 PT 15.82 (131} Q 44.55 F=0 F 0.00 PE 0.00 BN T 9.00 0.0057 PF 0.05 123 127DQ 44.62 2.703 L 9.00 C=120 PT 15.87 (127) Q 89.17 F=0 F 0.00 PE 0.00 BN T 9.00 0.0206 PF 0.19 119 123DQ 44.88 2.703 L 9.00 C=l20 PT 16.06 (123) Q 134.06 F=0 F 0.00 PE 0.00 BN T 9.00 0.0438 PF 0.39 115 119DQ 45.43 2.703 L 9.00 C=120 PT 16.45 {119) Q 179.49 F=0 F 0.00 PE 0.00 BN T 9.00 0.0751 PF 0.68 38 llSDQ 46.35 2.703 L 7.75 C=l20 PT 17.13 (115) Q 225.84 F=0 F 0.00 PE 0.00 BN T 7.75 0.1148 PF 0.89 PT 18.02 ( 38) ------------------126 130 2.703 L 9.00 C=l20 PT 15.85 (130) Q 44.59 F=0 F 0.00 PE 0.00 'BN T 9.00 0.0057 PF 0.05 122 126DQ 44.66 2.703 L 9.00 C=120 PT 15.9Q (126) Q 89.25 F=0 F 0.00 PE 0.00 BN T 9.00 0.0206 PF 0.19 118 122DQ 44.92 2.703 L 9.00 C=120 PT 16.09 (122) Q 134.18 F=0 F 0.00 PE 0.00 BN T 9.00 0.0438 PF 0.39 114 118DQ 45.47 2.703 L 9.00 C=120 PT 16.48 (118} Q 179.65 F=0 F 0.00 PE 0.00 BN T 9.00 0.0752 PF 0.68 37 114DQ 46.39 2.703 L 7.75 C=120 PT 17.16 {114) Q 226.04 F=0 F 0.00 PE 0.00 BN T 7.75 0.1150 PF 0.89 PT 18.05 ( 37) ------------------125 129 2.703 L 9.00 C=120 PT 15.95 (129) Q 44.74 F=0 F 0.00 PE 0.00 BN T 9.00 0.0057 PF 0.05 121 125DQ 44.81 2.703 L 9.00 C=120 PT 16.00 (125) Q 89.54 F=0 F 0.00 PE 0.00 BN T 9.00 0.0207 PF 0.19 SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 4 greyhawk bldg z .45/3000 roof Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 117 121D0 45.07 2.703 L 9.00 C=120 PT 16.19 (121) Q 134.61 F=O F 0.00 PE 0.00 BN T 9.00 0.0441 PF 0.40 113 117DQ 45.62 2.703 L 9.00 C=120 PT 16.59 (117) Q 180.23 F=O F 0.00 PE 0.00 BN T 9.00 0.0757 PF 0.68 36 113DQ 46.54 2.703 L 7.75 C=120 PT 17.27 {113) Q 226.78 F=O F 0.00 PE 0.00 BN T 7.75 0.1157 PF 0.90 PT 18.17 ( 36) ------------------120 124 2.703 L 9.00 C=120 PT 18.42 (124) Q 48.06 F=0 F 0.00 PE 0.00 BN T 9.00 0.0066 PF 0.06 116 120D0 48.14 2.703 L 9.00 C=120 PT 18.48 (120) Q 96.20 F=O F 0.00 PE 0.00 BN T 9.00 0.0237 PF 0.21 112 116DQ 48.42 2.703 L 9.00 C=120 PT 18.69 (116) Q 144.62 F=O F 0.00 PE 0.00 BN T 9.00 0.0503 PF 0.45 35 112DQ 49.00 2.703 L 7.75 C=120 PT 19.14 (112} Q 193.62 F=O F 0.00 PE 0.00 BN T 7.75 0.0864 PF 0.67 PT 19.81 ( 35} ------------------107 103 2.703 L 9.00 C=120 PT 17.70 (103) Q 47.11 F=O F 0.00 PE 0.00 BN T 9.00 0.0063 PF 0.06 111 107DQ 47.19 2.703 L 9.00 C=120 PT 17.76 (107) Q 94.30 F=O F 0.00 PE 0.00 BN T 9.00 0.0228 PF 0.21 38 111DQ 47.46 2.703 L 1.25 C=l20 PT 17.97 (111) Q 141.76 F=O F 0.00 PE 0.00 BN T 1.25 0.0485 PF 0.06 28 38DQ 225.84 2.703 L 0.83 C=120 PT 18.03 38) Q 367.60 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2828 PF 9.68 PT 28.07 28) ------------------106 102 2.703 L 9.00 C=120 PT 17.73 (102} Q 47.16 F=O F 0.00 PE 0.00 BN T 9.00 0.0063 PF 0.06 SUBMilTAL SERIAL N0:4144HY1 10-03-2005 PAGE 5 greyhawk bldg z .45/3000 roof Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 110 106DQ 47.23 2.703 L 9.00 C=120 PT 17.79 (106) Q 94.39 F=O F 0.00 PE 0.00 BN T 9.00 0.0229 PF 0.21 37 llODQ 47.50 2.703 L 1.25 C=120 PT 18.00 (110) Q 141. 89 F=O F 0.00 PE 0.00 BN T 1.25 0.0486 PF 0.06 27 37DQ 226.04 2.703 L 0.83 C=120 PT 18.06 37) Q 367.93 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2833 PF 9.70 PT 28.12 ( 27) ------------------105 101 2.703 L 9.00 C=120 PT 17.84 (101) Q 47.31 F=O F 0.00 PE 0.00 BN T 9.00 0.0064 PF 0.06 109 lOSDQ 47.38 2.703 L 9.00 C=120 PT 17.90 (105) Q 94.69 F=O F 0.00 PE 0.00 BN T 9.00 0.0230 PF 0.21 36 109DQ 47.66 2.703 L 1.25 C=120 PT 18.11 (109) Q 142.35 F=O F 0.00 PE 0.00 BN T 1.25 0.0489 PF 0.06 26 36DQ 226.78 2.703 L 0.83 C=120 PT 18.17 36) Q 369.12 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2850 PF 9.76 PT 28.29 ( 26) ------------------104 100 2.703 L 9.00 C=120 PT 19.46 (100) Q 49.40 F=O F 0.00 PE 0.00 BN T 9.00 0.0069 PF 0.06 108 104D0 49.48 2.703 L 9.00 C=120 PT 19.52 (104) Q 98.88 F=O F 0.00 PE 0.00 BN T 9.00 0.0249 PF 0.22 35 108DQ 49.76 2.703 L 1.25 C=120 PT 19.74 {108) Q 148.65 F=O F 0.00 PE 0.00 BN T 1.25 0.0530 PF 0.07 25 35DQ 193.62 2.703 L 0.83 C=l20 PT 19.81 35) Q 342.27 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2478 PF 8.48 PT 28.65 ( 25) ------------------4 5 7.758 L 320.00 C=lSO PT 78.06 5) Q 1153.11 F=GV F 6.04 PE 0.00 LU T 326.04 0.0091 PF 2.97 SUBMITI'AL SERIAL NO:4144HY1 10-03-2005 PAGE 6 greyhawk bldg z .45/3000 roof Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 11 4DQ -992.67 7.758 L 120.00 C=150 PT 81.03 4) Q 160.45 F=T,GV,EE F 72.53 PE 0.00 LU T 192.53 0.0002 PF 0.04 8 11 7.758 L 145.00 C=150 PT 81.07 { 11) Q 160.45 F=GV,T F 58.94 PE 0.00 LU T 203.94 0.0002 PF 0.04 PT 81.11 ( 8) ------------------6 5 7.758 L 157.00 C==l50 PT 78.06 5) Q 793.81 F=GV, 2EE F 33.22 PE 0.00 LU T 190.22 0.0046 PF 0.88 7 6 7.758 L 40.00 C=l50 PT 78.94 { 6) Q 793.81 F=0 F 0.00 PE 0.00 LU T 40.00 0.0046 PF 0.18 8 7 7.758 L 382.00 C=150 PT 79.12 ( 7) Q 793.81 F=T,GV F 58.94 PE 0.00 LU T 440.94 0.0046 PF 2.03 9 8DQ 160.45 7.758 L 259.00 C=lS0 PT 81.15 8) Q 954.26 F=2GV,2EE F 39.26 PE 0.00 LU T 298.26 0.0064 PF 1.91 12 9DQ -920.76 7.758 L 80.00 C=150 PT 83.06 9) Q 33.50 F=GV,T F 58.94 PE 0.00 LU T 138.94 0.0000 PF 0.00 3 12 7.758 L 215.00 C=lS0 PT 83.06 ( 12) Q 33.50 F=T,GV F 58.94 PE 0.00 LU T 273.94 0.0000 PF 0.00 PT 83.06 { 3) ------------------ 10 9 7.758 L 160.00 C=lS0 PT 83.05 9) Q 920.76 F=GV F 6.04 PE 0.00 LU T 166.04 0.0060 PF 1.00 1 10 7.758 L 326.00 C=lS0 PT 84.05 ( 10) Q 920.76 F=2EE,4GV,T F 104.24 PE 0.00 LU T 430.24 0.0060 PF 2.58 PT 86.63 ( 1) ------------------ 3 4 7.758 L 266.00 C=l50 PT 81.04 4) Q 992.67 F=2GV,EE F 25.67 PE 0.00 LU T 291.67 0.0069 PF 2.01 ········•-·••·--- , SUBMI'ITAL SERIAL NO:4144HY1 10-03-2005 PAGE 7 greyhawk bldg z .45/3000 roof Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 2 3DQ 33.50 7.758 L 75.00 C=lS0 PT 83.05 3) Q 1026.16 F=GV F 6.04 PE 0.00 LU T 81.04 0.0074 PF 0.60 1 2 7.758 L 314.00 C=150 PT 83.65 2) Q 1026.16 F=2GV,T,2EE F 92.16 PE 0.00 LU T 406.16 0.0074 PF 3.01 PT 86.66 ( 1) ------------------ 27 28 6.357 L 11.00 C=l20 PT 28.06 28) Q 367.60 F=0 F 0.00 PE 0.00 FM2 T 11.00 0.0044 PF 0.05 26 27DQ 367.93 6.357 L 11.00 C=120 PT 28.11 ( 27) Q 735.54 F=0 F 0.00 P·E 0.00 FM2 T 11.00 0.0159 PF 0.17 25 26DQ 369.12 6.357 L 11.00 C=120 PT 28.28 ( 26) Q 1104.66 F=0 F 0.00 PE 0.00 FM2 T 11.00 0.0336 PF 0.37 24 25DQ 342.27 6.357 L 5.50 C=120 PT 28.65 ( 25) Q 1446.92 F=T F 31.43 PE 0.00 FM2 T 36.93 0.0554 PF 2.05 23 24 6.357 L 30.25 C=120 PT 30.70 ( 24) Q 1446.92 F=O F 0.00 PE 0.00 FMl T 30.25 0.0554 PF 1.68 22 23 6.357 L 23.50 C=120 PT 32.38 ( 23) Q 1446.92 F=2E F 25.14 PE 9.32 FR T 48.64 0.0554 PF 2.69 21 22DQ 100.00 6.340 L 7.00 C=140 PT 44.39 ( 22) Q 1546.92 F=2E F 46.22 PE 0.00 UN T 53.22 0.0478 PF 2.54 20 21 5.914 L 56.00 C=l50 PT 46.93 ( 21) Q 1546.92 F=2E,EE F 53.92 PE 8.56 UN T 109.92 0.0590 PF 6.49 COMMENT: elevation difference from flow test taken here 5 20 5.914 L 15.00 C=150 PT 61. 98 ( 20) Q 1546.92 F=T,4E,DCA F 132.50 PE 0.00 UN T 147.50 0,0590 PF 8.70 6 11 DOUBLE CHECK DETECTOR ASSEMBLY 7.39 PT 70.68 5) " • SUBMITTAL SERIAL N0:4144HY1 greyhawk bldg z .45/3000 roof Location Flow Pipe Fittings in Size & From To GPM IN Devices ------------------0 1 7.758 Q 1946.92 F=O UN 10-03-2005 PAGE 8 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 1.00 C=lSO PT 86.64 1) F 0.00 PE o.oo T 1.00 0.0241 PF 0.02 PT 86.66 0)