Loading...
HomeMy WebLinkAbout3220 GREY HAWK CT; ; AS050207; Permit10/31/24, 3:38 PM AS050207 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS050207 3220 GREY HAWK Job Address: Status: ISSUED CT Permit Type: SPRINK Applied 10/5/2005 Parcel No: 2210150200 Approved: 11/22/2055 Lot#: 0 Reference No.: Issued: 11/22/2055 PC#: Inspector: Project Title: BLDGS. D/E FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: LIFEGUARD FIRE PROTECTION STE F 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 about:blank Owner: PALOMAR FORUM ASSOCIATES LP C/O DAVIS PARTNERS LLC 1420 BRISTOL ST N #100 NEWPORT BEACH CA 1/1 MATERIAL DATA SUBMITTAL GREYHAWK BUSINESS PARK BLDG. D/E, 3220 GREYHAWK CT. CARLSBAD, CA. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DRIVE, STE. F OCEANSIDE, CA 92056 760-806-9997 • 760-806-4813 FAX tqc:a I Fire & Bui/ding f Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Servi les: Tel: (414) 570-5000/ ( 00) 558-5236 Fax:(414)570-5010/( 00)877-1295 Series TY-FRB -2.8, 4.2, 5.6, and 8.0 K-facto Upright, Pendent, and Recessed Pendent Spri klers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, l,Jpright and Pendent Sprinklers described in this data sheet are quick response -standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 Inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate In a fire situation or cause it to operate prematurely. Page 1 of 8 mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing Is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the • Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Serles TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Fa/lure to do ao may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 - TY1231 • TY2131 • TY2231 • TY3131 - Upright 2.BK, 1/2"NPT Pendent 2.BK, 1/2"NPT Upright 4.2K, 1/2"NPT Pendent 4.2K, 1/2"NPT Upright 5.6K, 1 /2" NPT JULY, 2004 I 1 TY3231 • TY4131 • TY4231 • Technic Data Approvals UL and C-UL Listed. 5.6K, 1/2"NPT 8.0K, 3/4"NPT 8.0K, 3/4"NPT FM, LPCB, and NYC pproved. (Refer to Table A for mplete approval Information Including corrosion resis- tant status.) Maximum Working ressure 175 psi (12,1 bar) Discharge COefflcl• t K = 2.8 GPM/psi112 ( 0,3 LPM/bar112) K = 4.2 GPM/psi112 ( 0,5 LPM/bar112) K = 5.6 GPM/psi112 ( 0,6 LPM/bar112l K = 8.0 GPM/psi112 (1 5,2 LPM/bar1i2) TFP171 Page 2of8 ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 7/16" (11,1 mm) NOMINAL MAKE-IN j STYLE 10 or 20 RECESSED ESCUTCHEON ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN WRENCH FLATS -=----y'~ 2-3/16" (55,6mm) I SSP DEFLECTOR* PENDENT 1 -Frame 2-Button 3-Sealing Assembly 2-7/8" (73,0 mm) DIA. __j RECESSED PENDENT 4-Bulb 5 -Compression Screw 6 -Deflector 7-Bushing RGURE1 1/2" NPT** UPRIGHT * Temperature rating is Indicated on defle orifice seat on frame. •• Pipe thread connections per ISO 7/1 ca special request. QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINI( ERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3.'16" (55,6 mm) 7/16" (11,1 mm) NOMINAL MAKE-IN j STYLE 10 or 20 RECESSED ESCUTCHEON WRENCH FLATS SSP DEFLECTOR* PENDENT 2-7/8" (73,0 mm) DIA. __j RECESSED PENDENT 1 -Frame 2 -Button 3 • Sealing Assembly 4 -Bulb 5 -Compression Screw 6 -Deflector FIGURE2 ssu* DEFLECTOR 1/2" NPT** UPRIGHT 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3.'16" (55,6 mm) I • Temperature rating is indicated on defle orifice seat on frame. ** Pipe thread connections per ISO 7/1 ca special request. QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRIN/Ci 4.2 K-FACTOR, 112 INCH NPT Finishes Bulb .............. Glass Operatio TFP171 Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physlcal Characteristics Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . Compression Screw . . . . . Bronze Deflector . . . . . . . Copper/Bronze Bushing (K=2.8) . . . . . . . Bronze The glass Bulb con ns a fluid which expands when expo d to heat. When the rated temperatu is reached, the fluid expands sufficie tly to shatter the glass Bulb, allowing the sprinkler to activate and water to low. . . . . . Beryllium Nickel w/Teflont TFP171 Page 3of 8 ESCUTCHEON PLATE SEATING SURFACE 7116" (11,1 mm) NOMINAL MAKE-IN STYLE 10 or 20 RECESSED ESCUTCHEON ssu* DEFLECTOR 2-3/16" (55,6mm) SSP DEFLECTOR* PENDENT 1 -Frame 2 -Button 3 -Sealing Assembly t WRENCH FLATS 2·7/8" (73,0 mm) DIA. j RECESSED PENDENT 4 • Bulb 5 -Compression Screw 6 -Deflector FIGURE3 1/2" NPT** UPRIGHT 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3/16" (55,6 mm) i • Temperature rating is indicated on dell or or adjacent to orttice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) ANO PENDENT (TY3231) SPRIN ERS 5.6 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-5/16" (58,7mm) 1/2" (12,7 mm) NOMINAL MAKE-IN _l STYLE 30 or 40 RECESSED ESCUTCHEON WRENCH FLATS ssu* DEFLECTOR 2-1/4" (57,2mm) e* 2 3 SSP DEFLECTOR* PENDENT 2-7/8" (73,0 mm) DIA. J RECESSED PENDENT 3/4" NPT * UPRIGHT 4-Bulb 6-Deflector 1 -Frame 2 -Button 3-Sealing Assembly 5 -Compression Screw • Temperature rating is indicated on dell or or adjacent to orHice seat on frame. •• Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) ANO PENDENT (TY4231) SPRINK, ERS Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are Intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL 8.0 K-FACTOR, 314 INCH NPT Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent Installations. lnstallat The Series TY-FRB S rinklers must be installed In accordan with the follow- ing instructions: NO Do not install any bu! type sprinkler if the bulb Is cracked or there Is a loss of liquid from the bulb. ith the sprinkler Page4of8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROIIIE WHITE- LIQUID BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT 1ss°F/68°C Red (TY1231) 1, 2, 3, 5 and 11s°F/79°c Yellow UPRIGHT 200°F/93°C Green 2.8 (TY1131) 286°F/141°C Blue 1/2" NPT 135°F/57°C Orange RECESSED 1ss°F/68°C Red PENDENT (TY1231)* 11s°F/79°C Yellow Figure 5 200°F/93°c Green 1, 2, 5 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT (TY1231)** 175'F/79°C Yellow Figure& 200°F/93'C Green 135'F/57°C Orange PENDENT 155°F/68°C Red (TY2231) and 175°F/79"C Yellow UPRIGHT 200'F/93'C Green 42 (TY2131) 286'F/141'C Blue 1/2" 1, 2 NPT 135'F/57°C Orange RECESSED 1ss°F/68°c Red PENDENT (TY2231)" 175'F/79'C Yellow Figure 7 200°F/93°C Green 135'F/57°C Orange RECESSED 155'F/68°C Red PENDENT (TY2231)"" 175°F/79'C Yellow Figures 200'F/93°C Green NOTES• 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use In Cenads (C-UL) ss Quick Response Sprinklers. 3. Approved by Fadory Mutual Research Corporation (FM) as Quick Response Sprin- klers. • 5. Approved by the City of New York under MEA 354-01-E. . 7. Where Polye$1er Coated Sprinklers are noted to be UL and C-UL Listed, the spnn- klers are UL and C-UL Listed as Corrosion Res-nt Sprinklers. • Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPn 3/4" Total Adjustment Recessed EsaJlcheon, as applicable. •• Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. -• Frame and Delledor only. Listings and approvals apply to color (Special Order). NIA: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1 /16 inch (1,6 mm) for the 135°F/57"C to 3132 inch (2,4 mm) for the 286'F/141'C temperature ratings. A leak tight 1 /2 inch NPT sprinkler joint should be obtained with a torque of 7 ID 14 ft.lbs. {9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 112 NPT connections. A leak tight 314 TFP171 inch NPT sprinkler jo, t should be ob- tained with a tDrque f 10 to 20 ft.lbs. (13,4 ID 26,8 Nm). A maximum of 30 ft.lbs. (40, 7 Nm) of to~ ue is to be used to Install sprinklers th 314 NPT con- nections. Higher /eves of torque may distort the sprinkler nlet and cause leakage or impairmen of the sprinkler. Do not attempt to ma e-up for insuffi- cient adjustment In he escutcheon plate by under-or ov ,-tightening the sprinkler. Readjust th position of the sprinkler fitting ID sui The Serles TY-FRB right Sprinklers mu accordance with the tlons. Step 1. Pendent spri klers are to be installed in the pend nt position, and upright sprinklers are o be Installed in the upright position. Step 2. With pipe th ad sealant ap- plied to the pipe thre s, hand tighten the sprinkler into the prinkler fitting. Step 3. Tighten the prinkler into the sprinkler fitting using nly the W-Type 6 Sprinkler Wrench el. Figure 13). With reference to Fig res 1, 2, 3, and 4, the W-Type 6 Sprin ler Wrench is to be applied to the s rlnkler wrench flats. The Serles TY•FRB ecessed Pen- dent Sprinklers m t be installed in accordance with the llowlng Instruc- tions. Step A. After installi g the Style 10. 20, 30, or 40 Mountln Plate, as appli- cable, over the sprin ler threads and with pipe thread seal nt applied to the pipe threads, hand ti hten the sprin- kler Into the sprinkler ltting. Step B, Tighten the prinkler into the sprinkler fitting using only the W-1ype 7 Recessed Sprinkl r Wrench (Ref. Figure 14). With refer nee to Figure 1, 2, 3, and 4, the W-7 Recessed Sprinkler Wrench is o be applied to the sprinkler wrench ats. Step C. After the cei ing has been in- stalled or the finish t has been ap- plied, slide on the le 10, 20, 30, or 40 Closure over the Serles TY-FRB Sprinkler and push e Closure over the Mounting Plate until Its flange comes In contact wit the celling. TFP171 Page 5 of 8 SPRINKLER RNISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME WHITE-LEAD LIQUID BRASS PLATED POLYESTER COATED 135°F/57'C Orange PENDENT 155°F/68°C Red {TY3231) 1,2,3,4,5,6, 7 1, 2, 3, 5 and 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3131) 286°F/141 •c Blue 1/2" NPT 135°F/57'C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 4, 5 NIA (TY3231)' 175°F/79°C Yellow Rgure9 200°F/93°C Green 135°F/57'C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 1, 2,4, 5 NIA (TY3231)" 175°F/79°C Yellow Rgure 10 200°F/93°C Green 135°F/57'C Orange PENDENT 155°F/68°C Red (TY4231) 1,2,5 and 175°F/79°C Yellow 1,2,3,4,5,6, 7 UPRIGHT 200°F/93°C Green 8.0 (TY4131) 286°F/141 •c Blue 314• NPT 135°F/57'C Green RECESSED 155°F/68°C Orange PENDENT 1, 2, 4, 5 NIA (TY4231)' 175°F/79°C Red Rgure 11 200°F/93°C Yellow 135°F/57'C Orange RECESSED 155°F/68°C Red PENDENT 1,2,3,4,5 NIA (TY4231)" 175°F/79°C Yellow Rgure12 200°F/93°C Green NOTES: 1. Usted by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Usted by Underwriters Laboratories, Inc. for use In C&nsda (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Resaardl CQrporatlon (FM) as Quick Response Sprinklers. 4. Approved by the Loss P1'8\18nlion Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; howlll/8 LPCB does not rate Iha lhermal sensitivity of racessed sprinklers. ·, lhe 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For detalls contact 1yco Are & Building Products, Enschede, Netherlands, Tel. 31-53-42~x 3• ·53-428-33TT). 7. Approved by the Loss Pr11118ntlon Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. ~µL Ustedas 8. Where Polyester coated and Lead coated Sprinklers are noted to be UL and C-UL Usted, Iha sprinklers are UL and • Corrosion Resistant Sprinklers. Where Lead coated Sprinklers ere noted to be FM Approved, Iha sprinkle111 are FM A >proved as a Corrosion Resistant Sprinklet11. • Installed with Style 10 (1/2" NPT) or Style 40 (314" NPT) 314" Total Adjustment Recessed Escutcheon, as appllcable. -Installed with Style 20 (1/2" NPn or Style 30 (314" NPT) 1/2" Total Adjustment Recessed Escutcheon, as appllcable. -• Frame and Deflector only. Listings and approvals apply to color (Special Order). NIA: Not Available TABLES LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page8of8 518±114" (15.~.4mm) CLOSURE 2-718" DIA. ;l (73,0mm) 2-114" DIA. -j (57,2mm) r, 314• 19,1 mm 114" (6,4 mm) SERIES TY-FRB FIGURES 1-5116" 33,3 mm) 13116" (20,6 mm) 112<1/8" (12,7±3,2 mm) 2-718" DIA. ;l (73,0mm) 2-1/4" DIA. -j (57,2mm) r, FIGURE6 TFP171 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED P NDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON WITH TWO-PIECE 112 INCH TOTAL VSTMENT STYLE 20 RECESSED ESC HEON 2.8 K-FACTOR, 112 INCH NPT 2.8 K-FACTOR, 112 INCH PT 518,,1/4" (15,~.4mm) CLOSURE 2-718' DIA. ;l (73,0 mm) 2·1/4' DIA. -j (57.2 nvn> r I FIGURE7 314" 19,1 mm 1/4' (6,4 nun) 1-1/4" (31,8mm) 314" (19,1 mm) 1/2t1/8' (12,7"'3,2 nvn) CLOSURE 2-718" DIA. ;l (73,0 mm) 2-1/4" DIA. -j (57,2mm) r I FIGURES /2' 12,7mm) 1/4" (6,4 mm) 1-/4• 31,8 mm • (25,4mm) SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED P NDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON WITH TWO-PIECE 112 INCH TOTAL VSTMENT STYLE 20 RECESSED ESC HEON 4.2 K-FACTOR, 112 INCH NPT 4.2 K-FACTOR, 112 INCH PT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced In accord- ance with the following Instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation In a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fled sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinlder with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam-aged by dropping, triking, wrench twlsVsllppage, or the Ike, must be re- placed. Also, replace ny sprinkler that has a cracked bulb r that has lost liquid from Its bulb. Ref. Installation Section). Frequent visual lnsp lions are rec- ommended to be lniti ly performed for corrosion resistant ated sprinklers, after the installation has been com- pleted, to verify the i grity of the cor- rosion resistant coa ing. Thereafter, annual inspections per NFPA 25 should suffice; h r, instead of in- specting from the floo level, a random sampling of close-u visual inspec- tions should be mad , so as to better determine the exact sprinkler condl- TFP171 518±1/4' (15,9±6,4 mm) CLOSURE 2·7/8' DIA. ;l (73,0mm) 2-1/4' DIA. 7 (57,2mm) r I RGURE9 314' (19,1 mm) 1/4' (6,4 mm) MOUNTING PLATE 314' (19,1 mm) SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 518±1/4' (15,9±6,4 mm) (73,0 mm) 314" 19,1 mm 2·7/8' DIA. =;l 2-1/4' DIA. --j 1/4' (6,4 mm) (57,2 mm) _j I CLOSURE SERIES TY·FRB FIGURE 11 1-5/16' 33,3 mm 13116' (20,6 mm) SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT lion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. WRENCH RECESS (END 'B' USED FOR 3/4' NPT MODELS) 112±1/8' (12,7±3,2 mm) CLOSURE 2-7/8' DIA. ;l (73,0mm) 2-1/4' DIA (57,2mm) ~ Page 7 of 8 /2' 12,7 mm 1/4' (6,4 mm) 1-/4' 31,8 mm '(25,4mm) FIGURE10 SERIES TY-FRB RECESSED P. WITH TWO-PIECE 1/2 INCH TOTAL A VSTMENT STYLE 20 RECESSED ESCU7i HEON 5.6 K-FACTOR, 112 INCH N T 112±1/8' (12,7±3,2 mm) 2-7/8' DIA. (73,0mm) 2-1/4' DIA. (57,2mm) RGURE12 /'Z' 12,7 mm) 1/4' (6,4 mm) MOUNTING PLATE SERIES TY-FRB RECESSED PE DENT WITH TWO-PIECE 112 INCH TOTAL A VSTMENT STYLE 30 RECESSED ESCU7i EON 8.0 K-FACTOR, 314 INCH H T The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. F/GURE13 W-TYPE 6 SPRINKLER WRENCH It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Page 8 of 8 TFP171 P/N 57-XXX-X-XXX I I I TEMF ERATURE MODEL/SIN RI\TING SPRINKLER 330 2.8K UPRIGHT (1/2"NPT) TY1131 135 13! °F/57"C 331 2.8K PENDENT (1/2"NPT) TY1231 1 NATURAL BRASS 155 15! oF/68oC 340 4.2K UPRIGHT (1/2"NPT) TY2131 4 WHITE POLYESTER 175 17! °F/79°C 341 4.2K PENDENT (1/2"NPTI TY2231 3 WHITE (RAL901 O)* 200 20( °F/93°C 370 5.6K UPRIGHT (1/2"NPT) TY3131 9 CHROME PLATED 286 286 F/141°C 371 5.6K PENDENT (1/2"NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (314"NPT) TY4131 391 a.OK PENDENT (314 "NPT) TY4231 • Eastern Hemisphere :ales only. TABLEC PARTNUMBERSELECnON SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited ORY, FOR INCIDENTAL, INDIRECT, R-■Hd Escutche4 in: SPECIAL OR CONSEQUENTIAL Specify: Style (specH •) Recessed Es- Warranty DAMAGES, INCLUDING BUT NOT cutcheon with (spe, lfy finish), P/N LIMITED TO LABOR CHARGES, RE· (specify). GARDLESS OF WHETHER TYCO Products manufactured by Tyco Fire FIRE PRODUCTS WAS INFORMED 112" (15 mm) Products are warranted solelr to the ABOUT THE POSSIBILITY OF SUCH Slyle10 original Buyer for ten (1 O years DAMAGES, AND IN NO EVENT Chrome Plated .......... . PIN 56-701-9-010 against defects in material and work• SHALL TYCO FIRE PRODUCTS' LI· White Coaled ........... . PIN 56-701-+010 manship when paid for and properly ABILliY EXCEED AN AMOUNT White RAl.9010• ......... . PIN 56-701-3-010 Brass Plaled ............ . PIN 56-701-2-010 installed and maintained under normal EQUAL TO THE SALES PRICE. use and service. This warranty will ex-Itl.E. EQBE.GQUI.G. Wt1BBAtlD'. lS. 112" (15 mm) pire ten (10) years from date of ship-Style 20 ment by Tyco Fire Products. No war-MAQE. ltl LlEU. QE A.ta Atm. ALL Chrome Plated .......... . P/N 56-705-9-010 ranty is given for products or DTHE.B Wt1BBAtlDE.S. EXPRESS. QB White Coated ........... . P/N 56-705-4-010 components manufactured by compa-lMPLlE.Q ltlCLUDING W;gBBAtmE.S. Whtte RAl.9010" ......... . P/N 56-705-3-010 nies not affiliated by ownership with QE MEBCl:MtlT4B.lLlD'. AtlQ ElI· Brass Plated ............ . PIN 56-705-2-010 1yco Fire Products or for products and tlE.S.S. EQB A ~BIIC.ULAB l!.UB· 3/4" (20 mm) components which have been subject eDSE. Style 30 to misuse, Improper Installation, corro-Chrome Plated .......... . PIN 56-705-9-011 sion, or which have not been installed, White CoalBd ........... . PIN 56-705-4-011 maintained, modified or repaired in ac-Ordering White RAl.9010• ......... . PIN 56-705-3-011 cordance with applicable Standards of lltua Plated ............ . PIN 56-705-2-011 the National Fire Protection Associa-Procedure 3/4' (20mm) lion, and/or the standards of any other Style 40 Authorities Having Jurisdiction. Mate-@Dm-,01111 i.caJ distributor for avail• Chrome Plllled .......... . PIN 56-700-9-010 rials found by Tyco Fire Products to be ab~.lndlcate the White Coaled ........... . PIN 56-700-+010 defective shall be either repaired or lu product White RAl.9010• ......... . PIN 58-700-3-010 replaced, at Tyco Fire Products' sole name. Refer to Brass Plated ............ . PIN 58-700-2-010 the Prtce Ust for option. Tyco Fire Products neither as-complete llstlng • Eastern H• mlsphere aalea only. sumes, nor authorizes any person to of Part Numbers. assume for it, any other obligation in Sprinkler Wrench: connection with the sale of products or Sprinkler Assemblies with NPT Specify: W-Type 6 S1 1rinkler Wrench, parts of products. Tyco Fire Products Thread Connections: PIN 56·000-6-387. shall not be responsible for sprinkler Specify: (Specify Model/SIN), Quick Specify: W-Type 7 S >rinkler Wrench, system design errors or inaccurate or Response, (specify K-factor), (specify Incomplete information supplied by temperature rating), Series TY-FRB PIN 56-850-4-001 . Buyer or 8uyer's representatives. (specify Pendent or Uprl~ht) Sprinkler IN NO EVENT SHALL TYCO FIRE with (specify type of finis or coating), PRODUCTS BE LIABLE, IN CON-PIN (specify from Table C). TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE· TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010 I (800) 877-1295 Series EL0-231 B -11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description The 11.2 K-factor, Series EL0-2318, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Rel. Figure 1) are automatic sprin- klers of the frangible bulb type. They are "standard response -spray sprin- klers" that produce a hemispherical water distribution pattern below the de- flector. The 11.2 K-factor, EL0-231B Sprin- klers were subjected to full scale, high- piled storage, fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor stand- ard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, EL0-231 B Sprinklers - making their use highly advantageous in high density applications, such as the protection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy com- ponents used in Series EL0-231 B sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lead, and polyester coated sprin- klers have passed the standard corro- sion tests of the applicable approval agencies, the testing is not repre- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 sentative of all possible corrosive at- mospheres. Consequently, it is recom- mended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The ef- fects of ambient temperature, concen- tration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive na- ture of the chemical to which the sprin- klers will be exposed. An upright intermediate level version of the Series EL0-231 B Sprinklers for in-rack applications can be obtained by utilizing the Series EL0-231 B Up- right Sprinkler with the WSG-2 Guard & Shield, and a pendent intermediate level version of the Series EL0-231 B Sprinklers can be obtained by utiliz- ing the Series EL0-231 B Pendent Sprinkler with the WS-2 Shield. If there is a possibility of the pendent interme- diate level version being exposed to mechanical damage, a G-2 Guard can be added. WARNINGS The 11.2 K-factor, Series ELO-2318 Upright and Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Installation of Series ELO-2318 Pen- dent Sprinklers in recessed escutch- eons will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. JANUARY, 2005 ,. :---·-----:: :---...:_::......--:. : .::.:::.=.,~~: :· ; --:::-=---:--~-~----: ~ •·-~..,,. TFP342 Page 2 of 6 TFP342 SPRINKLER FINISH TYPE TEMPERATURE BULB NATURAL CHROME LEAD WAX WAX LIQUID BRASS PLATED COATED COATED OVER LEAD UPRIGHT 155'F/68'C Red 3 (TY5151 200'F/93'C Green & 1, 2, 3, 4 TY5851) 286'F/141 'C Blue 3 3<•) 155'F/68'C Red 3 PENDENT 200'F/93'C Green (TY5251 1, 2, 3, 4 286'F/141'C Blue 3 3(•) NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL Listed). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL Listed). 3. Approved by Factory Mutual Research Corporation (FM Approved). 4. Approved by the City of New York under MEA 291-04-E. (a). FM Approved for a maximum ceiling temperature of 150'F/66'C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K-FACTOR SERIES EL0-2318 UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Identification Numbers TY5151 -Upright 11.2K, 3/4"NPT TY5251 -Pendent 11.2K, 3/4"NPT TY5851 -Upright 11.2K, 1/2"NPT TY5151 is a redesignation for C5151. TY5251 is a redesignation for C5251, G 1871, and S2531 . TY5851 is a redesignation for C5851. Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Reier to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12, 1 bar) Discharge Coefficient K = 11.2 GPM/psil/2 (161,4 LPM/bar1i2) Temperature Ratings Reier to Table A Finishes Refer to Table A Physical Characteristics Frame . . . . . . . . . . . . . Bronze Cap .............. Bronze Sealing Assembly . . . . . . . . . . . ...... Beryllium Nickel w/Tellont Bulb (5 mm dia.) . . . . . . . Glass Compression Screw . . . . . Bronze Deflector . . . . . . . . . . . . Bronze t Registered trademark of DuPont. Design Criteria UL and C-UL Listing Requirements The 11.2 K-factor, Model ELO-231 B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with NFPA 13 standard sprinkler posi- tion and area/density flow calculation requirements for light, ordinary, or ex- tra hazard occupancies with a mini- mum residual (flowing) pressure of 7 psi (0,5 bar) in wet or dry pipe sprinkler systems, or they are to be installed in accordance with NFPA 13 standard sprinkler position and area/density flow calculation requirements for high piled storage occupancies (solid piled, palletized, rack storage, bin box, and shelf storage including but not limited to Class I-IV and Group A plastics) with a minimum residual (flowing) pressure of 10 psi (0,7 bar) for wet or dry pipe systems. The following example is typical of the type of arrangement permitted by NFPA 13. For all combinations of lesser and greater building heights, lesser and greater storage heights, storage arrangements, commodity classifications, and lesser or greater required design densities, refer to NFPA 13 for specifics. Example: NFPA 13 provides ceiling only protection (i.e., no in-rack sprin- klers) criteria using open frame (i.e. no solid shelves) single, double, multiple- row, or portable rack storage (without TFP342 * Temperature rating is indicated on deflector. ** Pipe thread connections per ISO 7/1 can be provided on special request. 2-13/16" (71,4 mm) TYP. 7/16" (11,1 mm) NOMINAL MAKE-IN UPRIGHT TV5851 2•** PT l112· (12,7 mm) NOMINAL MAKE-IN UPRIGHT TY5151 1/2' (12,7 mm) ~MINAL MAKE-IN THREAD RELIEF FIGURE 1 PENDENT TV5251 11.2 K-FACTOR SERIES EL0-231B 3/4"** NPT CROSS SECTION Page 3 of 6 Components: 1 -Frame 2 • Seal Assembly 3 • Cap 4 • Bulb 5 -Compression Screw 6 • Deflector * UPRIGHT-314" NPT (TY5151), UPRIGHT-1/2" NPT {TY5851), AND PENDENT-314" NPT (TY5251) SPRINKLERS the need for in-rack sprinkler protec- tion) of cartoned or uncartoned unex- panded Group A or B plastics, or, car- toned expanded Group A or B plastics, with: • a storage height of up to 20 feet (6, 1 m); • a maximum ceiling height of 27 feet (8,2 m); • a minimum deflector to top of stor- age clearance of 18 inches (457 mm); • a minimum design density of 0.60 gpmlft2 (24,4 mm/min); • a minimum residual (flowing) pres- sure of 10 psi (0, 7 bar); • a minimum design area of 2000 tie (186 m2) for wet systems or 2600 ft2 (242 m2) for dry pipe systems FM Approval Requirements The 11.2 K-factor, Model ELO-231 B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with the applicable "control mode den- sity/area" guidelines provided by Fac- tory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Installation The Series ELO-231 B Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40, 7 Nm) of torque is to be used to install sprinklers with 314 NPT connections. A leak tight 1/2 inch NPT sprinkler joint should be ob- tained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- "FITTING SIDE" TOWARDS SPRINKLER FITTING FIGURE2 W-TYPE 3 SPRINKLER WRENCH cient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series EL0-231 B Upright and Pendent Sprinklers must be installed in accordance with the following in- structions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 3 Sprinkler Wrench (Rel. Figure 2), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Page 4 of 6 Figure 1, the W-Type 3 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1 /8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the co"ect color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. Care and Maintenance Series ELO-231 B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system control valve for maintenance work on the fire protection system that it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. TFP342 It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national code. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for It, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL,. INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU Of ANY AND ALL OTHER WARRANTIES EXPRESS QR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT-NESS FOR A PARTICULAR PUB- .PD.SE. TFP342 Ordering Procedure A Part Number (P/N) is not specified when ordering sprinklers with thread connections per ISO 7 /1. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connection: Specify: (specify SIN), 11.2 K-factor, (specify temperature rating), Series ELO-231 B Standard Response (spec- ify Pendent or Upright) Sprinkler with (specify finish), P/N (specify from Ta- ble B). Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries ELO-231 B Sprinklers, P/N (spec- ify). Red for 155°F. Blue for 200°F and 286°F .. NOTES P/N 56-065-1-155 P/N 56-065-1-286 Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 150°F). 510 512 501 Page 5 of 6 P/N 50-XXX-X-XXX I SPRINKLER TEMPERATURE TYPE UPRIGHT 3/4" NPT (TY5151) PENDENT 3/4" NPT (TY5251) UPRIGHT 1/2" NPT (TY5851) 1 9 6 7 8 NATURAL BRASS CHROME PLATED WAX COATED LEAD COATED WAX OVER LEAD TABLES 155 200 286 PRODUCT SYMBOL NUMBER SELECTION 11.2 K-FACTOR SERIES EL0-231B RATING 155°F/68°C 200°F/93°C 286°F/141°C STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS Page 6 of 6 TFP342 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 A Gain Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010 / (800) 877-1295 Series TY-B -2.8, 5.6, and B.O K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response -standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, Is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 inch NPT) orStyle40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate In a fire situation or cause it to operate prematurely. Page 1 of 8 not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Serles TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-8 Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing Jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1151 - TY1251 • TY3151 - TY3251 • TY4151 - TY4251 - TY4851 - TY4951 - Upright 2.aK, 1/2"NPT Pendent 2.aK, 1/2"NPT Upright 5.6K, 1/2"NPT Pendent 5.6K, 1/2"NPT Upright a.OK, 3/4"NPT Pendent a.OK, 3/4"NPT Upright a.OK, 1/2"NPT Pendent a.OK, 1/2"NPT JULY, 2004 ~~ . ,., rA, I .• , ~~ TFP151 Page 2 of a ESCUTCHEON PLATE SEATING SURFACE 2-1/4' (57,2 mm) 7/16' (11,1 mm) NOMINAL MAKE-IN t ssp* DEFLECTOR ssu* DEFLECTOR 6 5 -+-----4 1"7---2 3 TFP151 PENDENT UPRIGHT CROSS SECTION 1-Frame 2 -Button 3-Sealing Assembty 4 • Bulb 5 -Compression Screw 6 -Deflector 7-Bushing FIGURE 1 * Temperature rating is indicated on deflector or adjacent to orttice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151} AND PENDENT (TY1251} SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6mm) 7/16" (11,1 mm) NOMINAL MAKE-IN t SSP DEFLECTOR* PENDENT 1 -Frame 2 -Button 3 -Sealing Assembly 4-Bulb 5 -Compression Screw STYLE 10 RECESSED ESCUTCHEON 6-Deflector FIGURE2 ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3/16" (55,6mm) 1/2" NPT** UPRIGHT l CROSS SECTION * Temperature rating is Indicated on deflector or adjacent to orttice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151} AND PENDENT (TY3251} SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT TFP151 Page 3 of 8 ESCUTCHEON PLATE SEATING SURFACE 1/2" (12,7 mm) NOMINAL MAKE-IN STYLE40 RECESSED ESCUTCHEON ssu* DEFLECTOR 2-5/16" (58,7 mm) _J_ WRENCH FLATS 2-1/4" (57,2 mm) s* 2 3 SSP DEFLECTOR* PENDENT 2-7/8" (73,0 mm) DIA. ---1 RECESSED PENDENT 3/4" NPT** UPRIGHT CROSS SECTION 1 -Frame 2 -Button 1 -Frame 2 -Button 3-sealing Assembly 4-Bulb 5 -Compresskm Screw 6 -Deflector 7 -Ejection Spring FIGURE3 * Temperature rating is indicated on deflector or adjacent to orHice seat on frame. ** Pipe thread connections per 150 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251} SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 7/16" (11,1 mm) NOMINAL MAKE-IN l ssp* DEFLECTOR ssu* DEFLECTOR * 6 5 2-3/16" (55,6mm 4 2 7 3 PENDENT UPRIGHT CROSS SECTION 3 -Sealing Assembly 4 -Bulb 5 -Compression Screw 6 • Deflector FIGURE4 * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per 150 7/1 can be provided on special request. • STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951} SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Page 4 of 8 TFP151 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE"' LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135•F151°c Orange PENDENT 155°F/68°C Red 2.8 (TY1251) 1,2,3 NIA 1/2" and 175°F/79°C Yellow NPT UPRIGHT 200°F/93°c Green (TY1151) 286°F/141 •c Blue 360°F/182°C Mauve 1, 2 135•F151•c Orange PENDENT 155°F/68°C Red (TY3251) 1,2,3,4,5,6, 7 1, 2, 3, 5 1, 2, 3, 5 1,2,3,5 and 175°F/79°c Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3151) 286°F/141°C Blue 1 ** ,2··, 3**, 5•• 1 **, 2*'°', 3**, 5•• 1/2" NPT 360°F/182°C Mauve NIA 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 NIA (TY3251)' 175°F/79°C Yellow Figure4 200°F/93°C Green 135°F/51°c Orange PENDENT 155°F/68°C Red (TY4251) 1, 2, 5 1, 2, 3, 5 1,2,5 and 175°F/79°c Yellow 1,2,3,4,5,6, 7 8.0 UPRIGHT 200°F/93°C Green 3/4" (TY4151) 286°F/141°C Blue 1**,2-, 3-*, s·· 1·-, 2 .. , 5•• NPT 360°F/182°C Mauve NIA 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 NIA (TY4251)' 175°F/79°C Yellow Figures 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red 8.0 (TY4951) 1/2" and 175°F/79°C Yellow 1,2,3,5 NIA NPT UPRIGHT 200°F/93°C Green (TY4851) 286°F/141 •c Blue 360°F/182°C Mauve NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. !or use In Csnsda (C-UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Cerllflcaflon Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss_ Prevention Cerllflcatlon Board (LPCB Ref. No. 094a/05). 8. Where Polyes1er Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coaled, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corroeion Resistant Sprinklers. • Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 314" Total AdjUstment Recessed Escutcheon, as applicable. •· 150°F/66°C Maximum Ceiling Temperature . ... Frame and deflector only. Listings and approvals apply to color (Special Order). NIA: Not Avellable TABI.EA I.ABORATORY I.ISTINGS AND APPROVAI.S TFP151 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING CLOSURE (73,0 mm) 3/4' (19, 1 mm) 2-7/8' DIA. ;l 2-1/4' DIA. 7 1/4' (6,4 mm) (57,2mm) r I FIGURES 1-1/4" (31,8 mm) 3/4" (19,1 mm) SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTIIENT STYLE 10 RECESSED ESCUTCHEON 5/8±1/4" (15,9±6,4 mm) CLOSURE 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. =;l (73,0 mm) 3/4' (19, 1 mm) 2-1/4" DIA. ---j 1/4" (6,4 mm) (57,2mm) JI SERIES TY-B RGURE6 1-5/16' (33,3 mm) 13/16' (20,6 mm) SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) Page 5 of 8 RGURE7 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS D PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURES W-TYPE 7 RECESSED SPRINKLER WRENCH Page &of 8 Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12, 1 bar) Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/bar112\ K = 8.0 GPM/psi112 (115,2 LPM/bar112) Temperature Ratings Refer to Table A Finishes Sprinkler: Reessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . . . . . . Beryllium Nickel w/Teflont Bulb ............... Glass Compression Screw . . . . . Bronze Deflector . . . . . . . . . . . Copper Bushing (K=2.8) . . . . . . . Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 1 0 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57"C to 3132 inch (2,4 mm) for the 360°F/182°C temperature ratings. A leak tight 1 /2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A teak tight 314 inch NPT sprinkler joint should be ob- tained with a torque of 1 O to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40, 7 Nm) of torque is to be used to install sprinklers with 314 NPT con- nections. Higher levels of torque may distort the sprinkler Inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Serles TY-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 1 O inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequenUy, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- TFP151 ing the wax coating. Before wrench tightening the sprinkler, the Jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1 /8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-haft inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The Serles TY-B Recessed Pendent Sprinklers must be Installed in ac- cordance with the following instruc- tions. Step A. After Installing the Style 1 o or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceillng has been in- TFP151 stalled or the finish coat has been ap- plied, slide on the Style 1 O or 40 Clo- sure over the Series TY-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, ~riking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the Installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as It may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service In accordance with local requirements and/or national codes. Limited Warranty Page 7 of 8 Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for It, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. ~RS8u'c:%NiEs~t'A'-m.r?rS> [bRtf. TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FQREGQING WARRANTY ts MADE IN LIEU QF ANY AND ALL QTHER WARRANVESEXPRESS QR !MPLIEQ INCLUDING WARRANTIES QF MERCHANTABILITY AND FIT- NESS FDR A PARTICULAR PUB- I!Ds.E. Page 8 of 8 TFP151 P/N 57-XXX-X-XXX I I I MODEUSIN SPRINKLER TEMPERATURE RATING 530 2.8K UPRIGHT (1/2"NPT) TY1151 NATURAL BRASS 135 135°F/S1°c 531 2.8K PENDENT (1/2"NPT) TY1251 4 WHITE POL VESTER 155 155°F/68°C 570 5.6K UPRIGHT (1/2"NPT) TY3151 3 WHITE (RAL901 O)" 175 115°F/79°c 571 5.6K PENDENT (1/2"NPT) TY3251 9 CHROME PLATED 200 200°F/93°C 590 8.0K UPRIGHT (3/4"NPT) TY4151 7 LEAD COATED 286 286°F/141 °C 591 8.0K PENDENT (3/4 "NPT) TY4251 6 WAX COATED 360 360°F/182°C 286°F/141°C MAX. 560 8.0K UPRIGHT (1/2"NPT) TY4851 8 WAX OVER LEAD 561 8.0K PENDENT (1/2"NPT) TY4951 286°F/141 °C MAX. TABLES • Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY-8 PENDENT AND UPRIGHT SPRINKLERS Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table B). Rece888d Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), PIN (specify). 1/2' (15 mm) Style 10 Chrome Plated......... PIN 56-701-ll-()10 112" (15 mm) Style 10 White Color Coated . . . .. .. .. .. .. .. PIN 56-701-4-010 112• (15 mm) Style 10 White RAL9010" . . . . . . . PIN 56-701-3--010 112" (15 mm) Style 10 Brass Plated........... PIN 56-701-2-010 314" (20 mm) Style 40 Chrome Plated......... P/N 56-700-9-010 314" (20 mm) Style 40 White Color Coated . .. .. . . .. .. . .. . PIN 56-700-4-010 314" (20mm) Style 40 White RAL9010" . . . . . . . PIN 56-700-3--010 314" (20 mm) Style 40 Brass Plated........... PIN 56-700-2-010 • Eastern Hemisphere sales only. Sprlnkler Wrench: Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries TY-B Sprinklers, PIN (specify). Black for 135"F ............ PIN 56-065-1-135 Red for 155°F ............. PIN 56-065-1-155 Yellow for 175"F..... . . . . PIN 56-065-1-175 Blue for 200"F and 286"F ................. PIN 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 1so°FJ. TYCO FIRE PRODUCTS. 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqc:a I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC-8 -8.0 K-factor Extended Coverage (l.ight Hazard} Customer Servi Tel: (414) 570-5000 / 00) 558-5236 Fax: (414) 570-5010/ 800) STT-1295 Pendent and Recessed Pendent Sprinklers General Description The Series EC-8 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprin- klers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon pro- vides up to 1/2 inch (12, 7 mm) of total adjustment from the flush pendent po- sition, whereas, the Style 40 provides 3/4 inch (19, 1 mm) of vertical adjust- ment from the flush pendent position. The adjustment provided by the Re- cessed Escutcheons reduces the ac- curacy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to ex1end the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-8 Extended Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may Impair the per- formance of thesa devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY4232 -Pendent, 8.0K TY4232 is a redesignation for C4232. JANUARY, 2005 Technic Data Approvals UL and C-UL Listed. Mand NYC Ap- proved. (Refer to Tab e A for complete approval information including corro- sion resistant statu . The approvals apply to the service conditions indi- cated in the Design riteria section.) Maximum Working ressure 175 psi (12, 1 bar) Discharge Coefflcle ts K = 8.0 GPM/psl112 (115,2 LPM/bar112) TFP223 Page 2 of 6 Components: 1 • Frame 2 • Button 3 • Sealing Assembly 4·Bulb 2 5 • Compression Screw 3 6 • Deflector* * Temperature rating is 4 Indicated on Deflector. ** Pipe thread connections per ISO 7/1 can be provided on special request TFP223 FIGURE 1 SERIES EC-8 (TY4232) EXTENDED COVERAGE PENDENT SPRINKLERS (See Note 4) HAZARD TYPE TEMP. BULB NATURAL WHITE• LIQUID BRASS POLYESTER LIGHT PENDENT 135'F/57°C Orange 155'F/68°C Red 1, 2, 3 5 Refer lo Table B for UL and C-UL Sensitivity Rating REC. PENDENT 135'F/57'C Orange and w/ Style 30 Esc. 155'F/68'C Red 1, 2, 3 5 Refer to Table C for FM Sensitivity Rating REC.PENDENT 135'F/57'C Orange w/ Style 40 Esc. 1ss°FIss·c Red NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Resistant Sprinklers. 5. Approved by the City of New York under MEA 113-04-E. •Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Temperature Ratings 135°F/57°C and 155°F/68°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coaled, Chrome Plated, and Brass Plated Physical Characteristics Frame . . . . . . . . . . . . Bronze Button . . . . . . . . . . . . . Bronze Sealing Assembly . . . . . . . . . . . . . . . Beryllium Nickel w/Teflont Bulb . . . . . . . . Glass (3 mm dia.) Compression Screw . . . ................ Bronze Deflector . . . . . . . . . . . . Brass t Registered trademark of DuPont Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The Series EC-8 Extended Coverage Pendent Sprinklers must only be in- stalled in accordance with the applica- ble UL and C-UL Listing or FM Ap- proval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installatio , as applicable (Ref. Table A, B, and ). UL and C-UL Llstln Requirements 1. The Series EC-8 used for the cove In Table D, based minimum specifi function of covera ard group for all the design area. prlnklers may be ge areas shown n maintaining the flow rate as a e area and haz- the sprinklers in 2. With respect to h at sensitivity, the Series EC-8 Sprln lers can be used with unobstructed onstruction con- sisting of flat, s oth ceilings (in- cluding bar Joists) with a maximum pitch of one in si as defined and permitted by NFP 13. 3. The minimum allo TFP223 AREA STYLE 16 X 16 Pendent 16 X 16 Style 30 Recessed 16x 16 Style 40 Recessed 18 X 18 Pendent 18 X 18 Style 30 Recessed 18 X 18 Style 40 Recessed 20x20 Pendent 20x20 Style 30 Recessed 20x20 Style 40 Recessed QR: Quick Response SR: Standard Response Ni A: Not Applicable 13s•F 1ss°F QR OR QR OR QR OR QR OR OR SR QR SR OR SR QR SR SR SR TABLES SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 135°F 1ss°F AREA STYLE 16 X 16 Pendent QR OR 16 X 16 Style 30 Recessed QR N/A 16 X 16 Style 40 Recessed N/A N/A 18 X 18 Pendent QR QR 18 X 18 Style 30 Recessed OR N/A 18 X 18 Style 30 Recessed NIA N/A 20x20 Pendent OR QR 20x20 Style 30 Recessed QR N/A 20x20 Style 40 Recessed NIA NIA QR: Quick Response SR: Standard Response Ni A: Not Applicable TABLEC SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-8 SPRINKLERS tween the Series EC-8 Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). 4. The Series EC-8 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for ex- tended coverage pendent sprin- klers. FM Approval Requirements The Series EC-8 Extended Coverage Sprinklers are to be installed in ac- cordance with the applicable Factory Mutual Loss Prevention Data Sheet. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spacing, and deflector-to ceiling distance. Page 3 of 6 lnstallat n The Series EC-8 Sp inklers must be installed in accordan with the follow- ing instructions: NOTi Do not Install any bu/ type sprinkler if the bulb is cracked o there is a loss of I/quid from the bulb. Ith the sprinkler held horizontally, a mall air bubble should be present. T diameter of the air bubble Is approxl ately 1/16 Inch (1,6 mm). A leak tight 3/4 Inch T sprinkler joint should be obtained w th a torque of 10 to 20 ft.lbs. (13,4 to 2 ,8 Nm). A maxi- mum of 30 ft.lbs. (40 7 Nm) of torque is to be used to i tall sprinklers. Higher levels of torq may distort the sprinkler inlet with nsequent leak- age or impairment of he sprinkler. Do not attempt to co pensate for in- sufficient adjustment fan Escutcheon Plate by under-or o r-tightening the Sprinkler. Readjust t e position of the sprinkler fitting to sui Step 1. The sprinkler ust be installed with the deflector par llel to the mount- ing surface. Pendent sprinklers must be installed in the pe dent position. Step 2. After installin the Style 30 or 40 mounting plate ( r other escutch- eon, as applicable) er the sprinkler pipe threads, and ith pipe thread sealant applied to t e pipe threads, hand tighten the s rinkler into the sprinkler fitting. Step 3. Wrench tight klers using only the -Type 3 (End A) Sprinkler Wrench. W ench tighten the recessed pendent prinklers using only the W-Type 4 S rinkler Wrench. The wrench recess f the applicable sprinkler wrench (Re . Figure 4 and 5) is to be applied to the prinkler wrench flats (Ref. Figure 1 ). Page 4 of 6 DESCRIPTION TY4232 (K=B.0) PENDENT 1 fl. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3. 785 1pm 1 psi = 0.06895 bar 1 gpmlft2 = 40. 7 4 mm/min AREA 16 X 16 18 X 18 20x20 TABLED GPM 26 33 40 PSI 10.6 17.0 25.0 FLOW CRITERIA FOR UL ANO C-UL LISTING OF SERIES EC-8 SPRINKLERS 1/2±1/8' (12,7±3,2 mm) FACE OF SPRINKLER FITTING \ (73,0mm) 2-1/4' DIA. (57,2mm) 1/2' (12,7 mm) 1/4' (6,4 mm) 1-1/4' (31,8 mm) 1' (25,4 mm) FIGURE2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 9/16±1/4' (14,3±6,4 mm) FACE OF SPRINKLER FITTING \ 2-1/4' DIA. (57,2 mm) 3/4' (19,1 mm) 1/4' (6,4 mm) 1-5/16' (33,3 mm) 13/16' (20,6 mm) FIGURE3 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON TFP223 'FITTI E' TOWARDS KLER FIGUR 4 W-TYPE 3 SP INKLER WREN H , ---- ' ' WRE CH REC SS fr ,_ - ® ,-----' ¢:I CD ,' ' ---1 _____ _:~~.I--...A FIG WRENCH LUGS W-TYPE4 SEO SPRINKLE NCH Care an Mainten The Series EC-8 Sp inklers must be maintained and ser iced In accord- ance with the followin instructions: NO Before closing a fire otectlon system main control valve r maintenance work on the fire prof tion system that it controls, permissi n to shut down the affected fire p~ action systems must be obtained om the proper authorities and all pa onnel who may be affected by this a tion must be no- tified. Sprinklers that are lo nd to be leaking or exhibiting visible s ns of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coat d, or otherwise altered after leaving t e factory. Modi- fied sprinklers mu t be replaced. Sprinklers that have een exposed to TFP223 corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Rel. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verily the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per N FPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA .25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (1 0) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (1 O} years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FQREGQING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANT/ES EXPRESS QR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT• NESS FDR A PARTICULAR PUR-~ Page 5 of 6 Ordering Procedu e When placing an orde , indicate the full product name. Pie se specify the Sprinkler ldentificatio Number (SIN}, quantity, and tempera ure rating. Refer to the Price List for c mplete listing of Part Numbers. Contact your local di ributor for avail- ability. Sprinkler Assemblie with NPT Thread Connection Specify: TY 4232, (sp cify temperature rating), Extended C erage Pendent Sprinkler with (spe ify finish), P/N (specify). 135"F/57"C Natural Brass ............. PSN 50-801-1-135 White Coated ............. PSN 50-801·4·135 White (RAL9010)" .......... PSN 50-801-3-135 Chrome Plated ............ PSN 50-801-9-135 155'F/68"C Natural Brass ............. PSN 50-801-1-155 White Coated ............. PSN 50-801-4-155 White (RAL9010)" .......... PSN 50·801-3-155 Chrome Plated ............ PSN 50-801-9-155 "Eastern Hemisphere s les only. Recessed Escutche n: Specify: Style (30 o 40) Recessed Escutcheon with (sp city finish), P/N (specify). Style 30 Receasad Eacutc eon Chrome Plated ............ PSN 56· 705·9·01 1 White Color Coated ........ PSN 56-705-4-011 White (RAL9010)" .......... PSN 56-705·3·011 Brass Plated .............. PSN 56-705-2-011 Style 40 Recessed Eacutc eon Chrome Plated ............ PSN 56-700-9-010 White Color Coated ........ PSN 56-700-4-01 0 White (RAL9010)" .......... PSN 58-700-3-010 Brass Plated .............. PSN 56-700-2-01 0 'Eastern Hemisphere Sprinkler Wrench: Specify: W-Type 3 S rinkler Wrench, P/N 56-895-1-001 Specify: W-Type 4 R essed Sprinkler Wrench, P/N 56-875· -001 Page 6 of 6 TFP223 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 46 INCORPORATED CORONA, CA• (909) 737·5599 FIG. 68 WIDE THROAT TOP BEAM "C" CLAMP WITH LOCKNUT Size Range -3/8 thru 7/8 inch rod. Function -For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals -Conforms to Manufacturers Stand- ardization Society SP-69, type 19. Finish -Plain and Electro-Galvanized. Order By -Figure number, rod size, and finish. Note -Do not overtighten set screw. FIG. 69 BEAM CLAMP RETAINING STRAP Size Range -3/8 thru 8 inch rod by 4 thru 14 inch length. Material -Carbon Steel Function -To offer more secure fastening of beam clamp to beam when danger of movement might be expected. Approvals -Underwriters' Laboratories listed when used with Tolco U.L. Listed Fig. 65 and 66 Universal Beam Clamp. Finish -Mil. Galvanized and Stainless Steel. Order By -Figure number, type, length "A", and rod size being used with beam clamp. Note -Minimum return on Strap: l". TYPE 1 2 3 10 3/8 • 7/8 A HOLE STOCK SIZE SIZE A FINISH 7/16 16gaxl t Mil. Galv. 9/16 16~xt ·· ··, .. ;fJ· ,.{r,;g1;;;~,MJ1;;J3~bhi<,> . 11/16 14gaxl-1/4 t Mil. Galv. 13/16 149~4,:l/4}11\; .;;{,t~tftJ:Mi~i~iMYJ"3~'°;\, specify 12gaxl-l/4 t Mil. Galv. INCORPORATED CORONA. CA• (909) 737-5599 FIG. 65 AND FIG. 66 45 REVERSIBLE C-TYPE BEAM CLAMPS -3/4" AND 1-1/4" THROAT OPENINGS -~ Size Range • (Fig. 65) 3/8 thru 5/8 inch rod B --j c \ (1/2 thru 10 inch pipe). FIG. 65 ~ Size Range -(Fig. 66) 3/8 thru 5/8 inch rod 77"--A (1/2 thru 10 inch pipe). D , I Material -Carbon Steel with hardened cup point _L_ : : set screw and jam nut. E Function -Recommended for hanging from steel ,-- beam where flange thickness does not exceed 3/ 4" L_ ..J.-:l-/ (Fig. 65) or 1-1/4" (Fig. 66). Features -All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engage- ment. Application Note -Fig. 65: add 1-1/2" to rod length when clamp is to be used in set screw up position. Fig. 66: add 2" to rod length when clamp is to be used in set screw up position. Approvals -Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 23, and Manufacturers Standardization Society SP-69, type 19 and 23. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet #13, 3/8" rod will support 1/2 thru 4" pipe, 1/2" rod will support 1/2 thru 8" pipe. Finish • Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By -Figure number, rod size, and finish. .--- C j_ F JQ __ Q~ I ROD SIZE A 3/8 1/2 5/8 ROD PIPE SIZE 1/2·4 5,.8 10 SIZE PIPE A SIZE B 1 • 3/16 1-1/2 ·' 1 • 1/2 B FIG. 66 FIG. 65 TABLE MAX. APPROX. REC. WEIGHT C D E F LOAD LBS. PER 100 3/4 1 7 /16 1 1500 28 3/4 / 1.:, 9/iijtil,lJ.ilthti;;;Q~Pf,{ i~i:~;f, 3/4 1 9/16 1 -1/4 FIG. 66 TABLE MAX. APPROX. REC. WEIGHT C D E F LOAD LBS. PER 100 3/8 1/2 5/8 1/2 · 4 5, 8- 10 1·3/161 • 1/4 1 7/16 1 1500 32 1-1;:2 ' 1 -i/4ri<}91.:1'6Bi1'tl:k4}<,il40ao;L:e; i6rlf i ··• 1 • 1/2 1 • 1/4 1 9/16 1 • 1/4 1'ia INCORPORATED 120 CORONA, CA• (909) 737.5599 FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range • Pipe size to be braced: 1" through 8" Sch. 10 and 40. Pipe size used for bracing: 1" and 1-1/4" Sch. 40 JPS. Material • Carbon Steel Function • For bracing pipe against sway and seismic disturbance. The pipe attachment com• ponent of a sway brace system: Fig. 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe per NFPA #13*, forming a complete sway brace assembly. Features • Can be used to brace Schedules 10 and 40 JPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes individually packaged with illustrated installation instructions • sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector that necessary minimum torque (5 lb/ft) has been achieved. Application Note• Fast Clamp need not be field assembled. Position Fast Clamp and tighten two hex nuts until leaf spring flattens. *Length of bracing pipe per National Fire Protection Association, Pamphlet #13, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7'·2". l·l/4" Schedule 40 bracing pipe maximum 9'·2". Approvals • Underwriters' Laboratories listed. Note• Must be used with Tolco U.L. Listed 900 Series attachment. Finish • Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By • Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. 0 ~ ) / ~ didi-- ~~ \ I ------. I , I / I I I ! ___ _lj __,, Schedule-108/Schedule-409 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-1 O/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 ( 111, "-8") pipe and Sch-40 (I"-2 i,,; ") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-I O/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4 .5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test NPS ln;mm 1" 25 1¼" 32 1½" 40 2' 50 2½' 65 NPS ln;mm 1' 25 1¼' 32 1½" 40 2' 50 2½" 65 3' 80 4" 90 5' 125 6' 150 8' 200 tqc:a I Row Control ~ allied TUBE & CONDUIT Sch-40 Specifications Nominal 1.0. Wt. Wt. (H20 FIiied) Pcs/ WVl.lft (21') Wt/lift (24') WI,,1.ift(25' ln;mm Lbs/Ft; Kglm Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 2,940 26.6 2.5 3.05 70 1,120 1,280 1,334 1.380 2.270 2.93 51 2,431 2,778 2,894 35.1 4.36 4.36 51 1,103 1,260 1,313 1.610 2.720 3.61 44 2,513 2,872 2,992 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 52.5 5.4 7.63 30 1,043 1,192 1,242 2.469 5.790 7.86 19 2,310 2,640 2,750 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-1 O Specifications Nominal 1.0. Wt. Wt. (H20 FIiied) Pcs/ Wlo'Lifl (21') WWII (24') Wt/lift (25' ln;mm Lbs/Ft; Kg/m Lbs/Ft Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 27.9 2.1 2.70 91 1,213 1,385 1,445 1.442 1.810 2.52 61 2,319 2,664 2,760 36.6 2.7 3.75 61 1,052 1,208 1,252 1.682 2.080 3.04 61 2,664 3,045 3,172 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 54.8 3.9 6.28 37 930 1,063 1,108 2.635 3.530 5.89 30 2,224 2,542 2,648 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 108.2 8.3 17,53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 161.5 13.8 34.27 10 885 1,012 1,053 8.249 16.490 40.15 7 2,424 2,770 2,885 209.5 24.5 59.75 7 1,100 1,256 1,309 ®<8>@ Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: (800) 882-5543 11350 Norcom Rd.• Philadelphia, PA 19154 2525 N. 27th Ave. • Phoenix, "'2. 85009 Fax 708-339-1806 S5-3 FOR USE WITH WET OR DRY SYSTEMS. GAUGES HAVE A BRONZE BURSON TUBE MOVEMENT IN A STAINLESS STEEL PLATED CASE (UNLESS OTHERWISE NOTED). 3-1/2" DIAMETER. U.L. AND F.M. APPROVED (UNLESS OTHERWISE NOTED). • 1~aoo~s4a ◄i94 AR• = AS REQUIRED Brecco Corporation GAUGES Part No. GAAWSS350 GMSS250 GAWP200 GMWP350 ► GAUGES <t. Description Box/Case 0111 AIR/WATER 0-300 PSI 80 WI STAINLESS STEEL CASE AIR WI RETARD 250 PSI 3-1/2" DIA. WI STAINLESS STEEL 80 CASE 2" RESIDENTIAL GAUGE 300 PSI 100 (NOT U.l. OR F.M APPROVED) AIR/WATER WI PLASTIC CASE 60 Fu: 1-877-474-9248 breccocorp@earthlink. n~t 082000 INCORPORATED CORONA, CA• (909)737-5599 30 FIG.909 NO,THREADSMVELSWAYBRACEAITACHMENT Size Range -1 and 1-1/ 4 inch bracing pipe. For brace pipe sizes larger than 1-1/4 inch use Talco Fig. 980. Material -Carbon Steel, hardened cone point engaging screw. Function -The structural component of a sway and seismic bracing system. Features- • No threading of the bracing pipe is required. • Open design allows for easy inspection of pipe engagement. • All steel construction eliminates deficiencies associated with malleable type attachments. • Fastener can be mounted to all surface angles. Application Note -The Fig. 909 is used in conjunction with the Tolco Fig. 1000 "Fast Clamp™", Fig. 2001, or Fig. 4(A) pipe clamp, and joined together with bracing pipe. Install per NFPA # 13 and/ or Tolco's State of California OSHPD Approved Seismic Restraint Manual. Installation -Extend bracing pipe through opening. Tighten cone point engaging screw until head bottoms out. Approvals -Underwriters Laboratories Listed per 203A (UL). Approved by State of California Office of Statewide Health, Planning and Development (OSI-IPD). Finish -Plain, Electro Galvanized and I-IDG. Order By -Figure number, pipe size and finish. Important Note -The Fig. 909 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the U.L Listing requires that the Fig. 909 must be used onlv with other To/co bracing products. NATIONAL AND INTERNATIONAL PA TENT APPLICATIONS IN PROCESS. MAX. MAX. HORIZONTAL HORIZONTAL DESIGN DESIGN PIPE LOAD LBS. LOAD LBS. APPROX. SIZE A B H' W/WASHER \VT./100 l 6 1-5/8 17/32 2015 2765 91 1-1/4 6 1-5/8 17/32 2015 2765 97 • Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory 0 State of California OSHPD APPROVED Standard washer (Fig. 115) required for 2765 lb. design load INCORPORATED CORONA, CA• (909) 737-5599 FIG. 4 STANDARD PIPE CLAMP Size Range -1/2 thru 30 inch pipe. Material • Carbon Steel Function -To carry piping where little or no insulation is required. For heavier loads, see Fig.4H. Approvals -Listed by Underwriters' Laboratories 2 -8 inch (1/2 -1-1/2 inch listed if E.G.). Approved by Factory Mutual Engineering, 1/2 • 8 inch. Federal Specification WW-H-171E, type 4, 1-1/2 thru 24 inch and Manufacturers Standardization Society SP-69, type 4. Maximum Temperature -750°F Finish -Plain, Electro-Galvanized, HDG, and Stainless Steel. Order By -Figure number, pipe size, and finish. 4-1/4 16 10-1/4 20 28 12-1/2 D --A C 2 5/8x2-1/2 19 MAX. REC. LOAD LBS. APPROX. FOR SERVICE TEMP. WEIGHT 650"F 750°F PER 100 500 445 29 2490 2220 3060 INCORPORATED CORONA. CA• (909) 737-5599 • I ' ', l' ' 1 ' -" I > \' l ••'-'' ! 1 , , , • , FIG. 51 AND FIG. 52 SIDE BEAM BRACKETS (CONT.) H-3 H-1 --H-2 • __ _ H-1 j_ 41 H-2 A I t:=:::jp:::::=J__l I [-l B I J · A-C FIG. 51 FIG. 52 FIG. 51 for NFPA Rod and Fastener Sizing PIPE ROD HOLE SlZE SIZE SIZE A B C H-1 H-2 FIG. 52 • 6 Hole Bracket HOLE SIZE C A-1 'c__j STOCK SIZE 3/16x2 APPROX. WEIGHT PER JOO 35 ROD SIZE A B C H-1 H-2 H-3 STOCK SIZE APPROX. WEIGIIT PER 100 3/Sxl/2 2 1-1/16 2 9/16 7/16 9/32 3/16x2 FIG. 56 TAPPED SIDE BEAM CONNECTOR Size Range • 1/2 thru 4 inch pipe (3/8 inch rod). Material • Carbon Steel Function -Practical and economical bracket used to support hangers from steel or wood beams. Can be used with concrete shot-type inserts. Tapped hole allows easy adjustment of hanger rod. Approvals -Underwriters' Laboratories listed and factory Mutual Engineering approved for 1/2 • 4" pipe. Finish • Plain, Electro-Galvanized, HDG, and Stainless Steel. Order By -Figure number and finish. Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8 inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch tastener. PIPE SIZE A ROD SIZE B C D E 1/2 • 4 2-5/8 3/8 1 3/8 1-1/16 HOLE SIZE STOCK F G H J SIZE 1-1/8 7 /16 9/16 1-1/4 1/4xl APPROX. WEIGHT PER 100 20 35 Submittal Data Sheet Super 40®/Dyna-Thread® Full Line Sch-40 Replacement Super -Hl/Dyn:1-Thrc:.1d sprinkler pipe represems an engineering udvnncemen1 for lhe sprinkler pipt: induslry. II combin..:~ th..: s.1fe1y and longc::vi1y of trldirional Sch-40 pipe wich qualiry and ~upcrior h~'dn.1ulic adv.inrng~!\. Comparison to Schedule 40 Super 40/Dynn-Threads inside diarnere.r is up <0 3.6% larger th:.rn Sch--10 gi\·ing i1 Sllperior hydrnulics. Also, when used in combinmion wirh Dyna-Flow prpe. down sizing of,en occurs. Super 40/Dyna-Thread is fully liSled ond approved UL, ULC, and FM for fire sprinkler ;1pplica1ions. The life expectancy of Super 40/Dynu-Thre:id and Sch-40 ure equal based on lhc calculaied wall thicknesses per UL (see CRR). The consis,enr qualiry of sreel u-.ed 10 make Super .:ltJ/Dymt-Thread facili1,nes smooth threading and lower mnimenance co:,;1s. The' t!.\lc'mW of Supc'r -lll/Dyna-Thre.td is prnrec1ed by a clean, dur;-ib\e mill couring for extemleJ sl.dt life :tnd ~;1sy paim i1pplica1ic111. Wi1h its increased :,;1reng1h and lighter weight, Super40/ D\n.1-Thre:.h .. 1 reducr.s ins1,,ll,Hion fotigue ,md is iJeal for re1ro-fi1 applic;11ions. Corrusion R,:..,l.'.tanL·e R:.11io 1CRR11s a UL. {Underwri1ers L1bormory) 1er111 for the t!s11111med life expt!cLancy ol ._1 pipe juin1. Thi$ is based on 1hi! calcula1ed wall thickness Lll the base of 1he first exposed rhread . .1:-:-.umeU IO be 1he \\c"~1kc:;t poim of the pipe leng1h. Super 40/Dyna-Thread ;rnd Sch-40 have 1he .,ame c~1kul:.11ed \\·:.111 thicknesse:,; :.11 1his poinl and :.ire both Jssigned che Sj\1lf.? CRR of 1.00. Comparison to L.W.T. Pipe More wall 1hickness a, ,he 1hread iCRR=l.00) gives Super -Hl/Dyn..1-Thread be11er life expectnncy 1hun ligh1wall 1hreadable pipe join1s. Unlike liµh1wa1I 1hrc-adahlc p1pe. Super 40/Dyna•Thread ha~ no thread gauge. warning. Super 40/ Dvnn-Thrc;.,d is ;.ipproved for standnrd hanger spacing ( 15 ft. O.C.J, can be used as eJnhqu:1ke sway Qn.tcing. and is safe ID use as drops. Super 40/Dyna-Thread is snfer 10 weld on rhan nrnny ,.rnc-cua,ed lighrn·nll 1hreadable pipe products. Super 40/Dyno-Thread is more widely accepted Lh;rn lighfwall lhreadable where Sch-40 is specified. Slarnp Her• Sp~ifications & Approvals Super-tfl/Dy1rn-Thre~1d pipe is innnufacrured w meer ASTM A 135. Grnde A and is in compliance 11 i1h NFPA-13. All sizes of Super 40/Dyna-Thrcad are rared at 300 psi working pressure. Super 40/ Dvna-Thread is UL ,rnd ULC Listed for wer, dry :.11id prc--:.1cuon sprinklc'r systems and FM Appro~•ed fl,r u:-.e in we1 systems. Super 40/Dynu-Thread can bl! .. hot-dip" gal\':mized 10 meet FM requirement Specifications a:1nc11u •=M■111c rl.,r Jry _.,y:;1ern.s. Super 40/Dyna-Thread is approveU lor all threaded C\)upling:.; ;rnd ~ielded outlels und is .--;L11wble for all roll-grooved, and plain-end fiuings. (See lis1ing infonmnion). Li.s1ud Lisied Product NPS )( 1" * 25 X 1 1/4" * 32 X 1 1/2" .40 ?" X - * 50 Nominal l.D. 1.080 27.4 1.408 35.8 1.639 41.6 2.104 53.4 Wt/Ft Wt/Ft H20 Filled 1.330 1.75 2.0 2.60 1.870 2.54 2.8 3.78 2.290 3.22 3.4 4.79 3.050 4.57 4.5 6.80 Pcs/ Wt/Litt Wt/Litt Wt/Lift Lift 21.' 24' 25' 70 1955 2234 2327 70 887 1013 1056 51 2002 2288 2384 51 908 1038 1081 44 2115 2418 2519 44 959 1097 1143 30 1921 2196 2287 30 871 996 '.L037 A1neriqn Tube and Pipe was acquired b)' Allied 'rube :rnd Conduit on February 1, 1997. The engineered light wall and standard wall family or products alt~ough they han' dillrrenl names are the same in all respects with regard to s1rength1 weight, bundle counl, lisLlngs and approrals. For example, Drn:i-Flow and Super Flo are 1he s:tme producl as nre Dynn Thrend ::ind Super ~O. XL is manufnctured with Exterior galvanized coaling. BLT is manufactured with Bh:1ck lacquer c'oating. ; Pro1ec1: Sprinkler Conlractor: Date: Engineer: Specification Relerence· System Type: Loca1,ons: Comments: Grooved IPS Fittings Victaulic fittings are designed specifically for use in grooved piping systems. Victaulic airers a broad line or fittings in sizes through 2411 (600 mm) in a variety of straight and reducing styles. Most standard fittmgs are cast or durable ductile iron to precise tolerances. Victaulic standard fittings pressme ratmgs conform to the ratings of Victaulic Style 77 couplings. All fittmgs are supplied with grooves or shoulders to permit last instaUat1on without field preparation. The grooved design permits fleXJbllity for easy alignment. These fittJngs are not intended for use with Victauh·c couplings for plain end pipe (refer to page 55 ior fittings available for plam end applications). Fittings are provided in vanous materials including maUeable iron. ductile iron. steel or s-egmentally' welded steel dependmg on styles and size. Fittings .are painted orange enamel with galvanized optionally available. contact Victaulic for details. Pipe Victnulic filtings are designed specificaUy for use in grooved piping systems. Fittings are provided grooved or with shoulders conformmg to standard steel pipe outside diameters. When connecting wafer or lug-rype butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange"' adapters. checl, disc clearance dimensions with I.D dimension ol fittmg. Request 07.01. Alternate Materials Stainless Steel -Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 optionally available) m various sizes. Fitting center-to-end dimensions will vary depending upon wve and schedule. Request 17 .04 for details. Aluminum -Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 -8" (25 -200 mm). Request 21.03 or contact Victaulic for details. Pipe Alternate Styles EndSeal® "ES" Fittings - EndSeal fittings are available in 2 - 12" (50 -300 mm) for use with "ES" grooved pipe and HP-70ES EndSeal or Fire-R"' couplings. "ES" fittings are painted green [or easy identification. EndSeal (anj standard) fittings may be easily internally coated (by others) for severe service requirements. Always specif\• "ES EndSeal fittings" when ordermg. Request 07.04 !or information on EndSeal fittings. Fittings Machined for Rubb,ar or Urethane Lining (MRL) -For severe abrasive services, Victauhc fittings may be rubber or urethane lined (by others). Lining may bf' inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Request 25.03 or contact Victaulic for speclfic details. Flow Data Friction Resistance lnches/m1T1 Equivalent FeeVmelers of Slraight Pipe Inches/mm Equivalenl FeeVmelers of Stralghl Pipe Tl,e chart expresses the frictional re3istance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimate,! from the data given. for example. a 22%0 elbow is apprOJarnately one-half the resistance of a 45° elbow. Values of m1d¥sizes can be interpolated. H 90° Elbows No. 100 No. 10 1)120 Norn. Aclual Sid. Long Size Size Radius Radius 1 1.315 1.7 - 25 33 "/ Os 2 2.375 35 2.5 ~10 60~ 11 0$ 3:j: 3.000 4.3 -761 1 3 3 3.500 5.0 3.8 80 M9 1 5 , '} 4 4.500 6.8 5.0 100 1,i.1 3 ~I 1S 4.250 6.4 -41/, :j: 1080 1 B 5 5.563 8.5 - 12b 1,113 2.6 5¼t 5250 8.1 -1330 25 - 5½t 5.500 8.5 -1397 26 - 6 :j: 6.250 9.6 -1590 .2..9 -- # Contact V1ctaul1c for details + 0. D. Dimension. 45" Elbows Tees No. 110 No. 11 lY.! D Sid. Long Radius Radius Branch Run 0.8 -4.2 1.7 Oc l 3 05 1.8 1.1 8.5 3.5 n :-i 03 2.6 11 2.1 -108 4.3 07 33 13 2.6 1.6 13.0 5.0 1.)8 05 40 15 3.4 2.1 16.0 6.8 10 Oti 'g 2.1 3 " -< -15.3 6.4 09 ➔ 7 20 4.2 -21.0 8.5 1.3 "" 26 4.1 -20.0 8.1 lti ti ;·~ ?.5 4.2 -21.0 8.5 1 3 "' .2.6 5.0 --25.0 10.0 1 5 76 30 90" Elbows 45° Elbows Tees No. 100 No.110 No. 10 1½0 No.11 1½D Norn. Actual Sid. Long Sid. Long Size Size Radius Radius Radius Radius Branch Run G 6.625 10.0 7.5 5.0 3.0 25.0 1(1.0 150 168 3 30 73 , 5 OH ,7 6 JO 6.500 9.6 -5.0 -25.0 10.0 6½:J: 105 1 ?.9 -1 ~~ 7 6 JO B 8.625 13.0 9.8 6.5 4.0 33.0 1,:.0 200 ;2191 so 3.0 Q.D , 2 101 40 10 10.750 17.0 12.0 8.3 5.0 41.0 11·.o ?50 2730 52 37 2.5 1.5 1~.5 5.:2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 SOD 3~3 9 6.1 J 4 30 1" 1!>2 G 1 14 14.000 # 23.0 # 18.0 60.0 17.0 350 3~ti G # 7.0 • ~-:i HI 3 ~ ~I 16 16.000 # 26.0 # 20.0 70.0 2(1,Q ,100 40G4 • 79 " 61 21 3 61 18 18.000 # 29.0 # 23.0 80.0 2~-.0 45l) .:.is·ro • 3.6 ' :o 24 4 70 20 20.000 ff 33.0 ff 26.0 90.0 25.0 500 ooso ,; 10 1 • 7.9 27 4 7.6 24 24.000 # 40.0 # 30.0 30.5 34.0 600 6100 • 12.2 ' 91 93 10..:1 e t t;W'k0ldlt'W2t t ti M!Cl?IXtt'MWr!»Wl Style 07 Zero-Flex® Rigid Coupling @@ ~ The unique angle· pad design of Zero-Flex® Style 07 adjusts to standard pipe and roll or cut groove tolerances, positively clamping the pipe to resist fiexural and torsional loads. Wider l<ey section fills more of the groove area. Request 06. 02. ,~'liWiollifi,IIJl.'il!il Style 77 Standard Flexible Coupling ®@ ~ Style 77 couplings are d,Jsigned witi1 cross-ribbed constJ uction to provide a strong component tor pressure piping systems. Sizes ¾ -12" (20 -300 111111) are two-piece housings. Sizes 14 -22" (350 -550 mm) are cast in lour identical segments, with larger sizes cast in six segments. Y----z r Request 06 04 X. / 1/ ~ / / Ill' ,./ ~--,.,,ev u~ ~ 'P. / ··~ ~· ~~5P . . . 2 ~ 12" Sizes 14-16~ Sizes 18 -24" Sizes ¼-12" Sizes 14 -22'' Sizes 24" Size Norn. Max.. Dimensions -Inches/mm Aprx. Size Work Press. Wgl. Each Norn. Max. Dimensions -Inches/mm Aprx:. Si:!:e Work Press. Wgt. Each lnches/rnm PSl./k.Pa X y z Lbs./1\Q Inches/nun Ps1·11,;Pa X y z Lbs./t,g 1 750 2.45 4.13 1.88 1.G 1/, 1.000 2.13 3.63 1.75 1.1 '~> !'>1::1 ri:! 1\):j ..iB tl ~ " (ii)f)\"1 ;,J iP .I.I ll!• 11/J 750 2.60 4.00 1.68 1.6 .\.' :1 I ::i titi hP ,llJ ll ~-1 1,000 2.38 3,88 1.75 1.3 ·•:--: 1i8\.)() tiO :):-: .1.1 {\(i 1½ 750 2.94 4.81 1.88 1.6 11/~ 1,000 2.63 4.63 1.75 2.0 "' :11,·.1 :, ,:·2 ·UJ " ti~X)(l d:" 111; -1-1 il!l 2 750 3.19 5.44 1.88 2.3 1½ 1.000 3.00 5.00 1.75 2.1 !1() .•l:"'.i :11 1·11 .1:: '" j\1 ti\}.)0 '(j 1:·· ,_, 111 2½ 750 3.88 6.13 1.88 2.8 2 1,000 3.63 5.63 1.75 2.6 ,)~ ;;1,"J illl 1:i6 .1;: 1,.; :-:l' ti9t'li."'l i)~' U...i LI ,_ 3* 750 4.25 5.75 1,86 3.6 ~>l ;!, ,tm U6 .,: "\(i 2½ 1,000 4.25 6.25 1.75 3.1 <)~ tirlOO 1{):; h!l ., .. , 1-1 3 750 4.56 6.81 1.88 3.1 :10 '.>17!> lh) 1:-:4 ,111 I -1 H 1,000 4.31 6.31 1.75 3.6 d\lOtl llil hii.'r " 1tl 4 750 5.81 8.25 2.06 4.8 3 1,000 5.00 7.00 1.75 3.5 100 ::1-'.'.; 1-1tl 2'10 s' ?2 (It) ti~lCII) 1:?.-l ;;i ,, lli 4V.t 750 5.56 7.44 2.06 5.2 :il ~-'., l•ll 1119 !i'.' .' d 3½ 1,000 5.63 8.00 1.75 5.6 ;in ,:~;oo 1-13 .0l).i ,_, ., 5 750 7.06 9.75 2.06 7.1 1 '!, :--1:-·5 17~1 _;-1~ !:>2 ,i_' 4 1,000 6.38 8.50 2.00 6.6 1i}I' d!)O;l 16:' -~ 7 ti :,1 :,o SY. t 700 6.36 9.18 2.06 7.4 :!~1''!1 17.i '.:;:, 5~' 3-t. 4V.t 1,000 5.88 8.06 2.06 7.0 (.,~k)(l 1--1~1 l(t!l :,,' -· 5½t 700 6.94 9.42 2.06 7.6 kl':1 i ;n ,'.t) :;~ ,'-I 5 ·1,000 7.63 10.25 2.00 10.6 ·.~J fr)l.lt) 1~)-i _\ill !d -1 H 6 700 8.00 10.75 2.06 8.7 l:Jll .iit!~> ~~03 :,::, 52 3-1 5¼:t: 1,000 7.34 9.20 2.06 10.0 u~no Hki .~Joi :1~• I!.• 61/, t 700 7.85 10.18 2.06 9.2 m.•~, 1~)9 '.''.1:"l S? F' 1,000 7.60 9.44 2.06 11.0 51/, t \i!)()\"1 l~l'.l .'W :12 :it) 6½t 700 8.00 10.75 2.06 7.2 -IS,'S ·1u:i ~.-.·:; !l? 32 6 1,000 9.00 11.50 2.00 11.8 1j{l m100 -'?!l .':l.' :,1 !l-1 8§ 600 10.25 nso 2.50 14.9 "\JO JUtl :'l-iO _j.\J ,i.cl li,'" 1,000 8.50 10.38 2.06 13.2 6%:t: ,i~.llX) ;.'lli .Jl~-1 1i1l 10 § 500 12.88 16.75 2.56 25.0 -~:-iU .kt!iO ?''"" i.>1~ 6'.) 1, ., 6,,t 1,000 9.19 11.50 2.06 13.2 li)OO .:.'3~) .·':12 :-2 \;(l 12 § 400 14.88 1850 2.56 28.2 ;11,)l) .·'7:1ll ,;,-tl 1:\j O:i 1 ~' t! 8§ 800 11.38 14.50 2.38 20.1 ,\)i.l ~'.lull n.i!l -~t,li ,;o !ll 14 300 16.19 19.75 2.94 32.8 .bl) .'11t;:) 011 :,P;> 7!, 14.1() 10 § 800 13.50 16.75 2.50 28.3 ''.)(' :,~,Jl.1 :1.:1.1 ·•?~ ii-I I:n 16 300 18.38 21.75 2.94 41.2 -l()O 'Ill~~ -11;:-;,:i.:; .-!l HI':' 12 § 800 15.50 19.00 2.50 34.2 .illl'J ::ii;.10 .i9-1 JB3 t>-1 1:,:, 18 300 20.69 23.88 3.06 54.2 14 300 16,63 20.00 2.88 35.6 ·1!>0 :'Oli:1 !_,",'li litX~ 7:"l /,1 t: :bl) '.(lt.)~ -t~:i !':-illl .-:~ lli 1 20 300 23.00 27.38 3.06 67.2 15 300 17.88 21.25 2.88 48.8 :1oi.1 XKi!i :)!14 ii!b /[1 :;() 5 :, -~-'))u'.; -1:>•l ,),\l) ; 3 .'' I 24 250 27.13 3150 3.13 76.2 16 300 19.00 22.38 2.88 51, 1 til)() 17~•:, ,i!.!) 20il 7~) .3-1 \~ ,!(if :.'Oo:i m3 '.1ti<l ., :':.l:' ::f: 0.0 01mens1on. • Reier lo notes on page 7 § Available lo J.I.S d1mens1on 18 300 21.25 24.38 3.13 64.4 .J!'itl -'0Ut> :,4{1 l~l\l -~, :•:J:' 20 300 23.50 27.50 3.13 91.2 !>00 :'(lt1;1 :1!l' (;\}9 -·!) '" t 22 300 25.63 30.00 3.13 92.0 !,~{) ..:tk'S lb1 ,,;? i"\) ... , : 24 250 27.63 31.38 3.13 94.0 L100 172:i :-o;.-;~F ;'~ I'.'{\ l OD. Dimension • Reier 10 notes on page 7 § Available to J.I S. d1men~Ion. 8 ·-Su-per Flo®/Dyna-FIOW® ,..._Iigh Strength Steel Pipe· The original high-strength lightwa/1 sprinkler pipe with hydraulics superior to Schedule-10. Super Flo/Dyna-Flow pipe is the "original" high-srrength lightwall sprinkler pipe. Super Flo/Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-IO pipe. Lightweight, easy to cut and easy to handle for installation. Super Flo/Dyna-Flow is a valuable addition to any fire protection system. Superior Hydraulics With an inside diameter of up to 11 % larger than Schedule-40 and up to 7% larger than Schedule-10, Super Flo/ Dyna-Flow pipe hydraulics are exceptional. ,-ger I.D.s enable Super Flo/Dyna-Flow, \ ui1d related components, to be down- sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Super Flo/Dyna-Flow Hydraulic Data Tables." • Coatings & Fabrication • Super Flo/Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paimable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No .---P.cial process or equipment are needed fabrication and installation. Specifications x=lnDhllS •=MlltJlc Product Nominal Wt;Ft Wt/Ft NPS I.D. H20 Filled X 1" 1.191 0.830 1.31 * 25 30.3 1.2 1.95 X 11/4" 1.536 1.059 1.87 "32 39.0 1.6 2,78 X 11/2" 1.728 1.667 2.71 *40 43.9 2.5 4.03 ?" X -2.203 2.104 3.79 * 50 56.0 3.1 5.64 X 2 1/2" 2.703 2.564 5.10 *65 68.7 3.8 7.59 X 3" 3.314 3.387 7.18 * 80 84.2 5.0 10.69 X 4" 4.310 4.473 10.86 * 90 109.5 6.7 16.16 X 6" 6.403 7.714 21.70 *150 162.6 11.5 32.29 Specifications & Approvals Super Flo/Dyna-Flow pipe is manufactured to meet ASTM A- 795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. Listed Approved Listed Super Flo/Dyna-Flow is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Super Flo/Dyna-Flow is now available "hot-dip" galvanized and has been specifically approved by FM for dry systems uses. Pcs/ Wt/Lift Wt/Lift Wt/Lift Lift 21' 24' 25' 91 1586 1812 1888 91 719 822 856 61 1356 1550 1615 61 615 703 733 61 2135 2440 2542 61 968 1107 1153 37 1634 1868 1946 37 741 847 883 30 1615 1846 1923 30 733 837 872 19 1351 1544 1608 19 613 700 729 19 1784 2039 2124 19 809 925 963 10 1620 1851 1928 10 735 840 875 Additional Benefits • Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. • Provides stability needed to comp! y with standard hanger spacing (l5 ft 0.C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in cuscom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and ;:icts as an excellent primer for custom paint applications. ,G;S allied TUBE & CONDUIT 16100 S. Lathrop Harvey, IL 60426 11350 Norcom Rd. Philadelphia, PA 19154 2525 N. 27th AYe. Phoenix, AZ 85009 Customer Service: 1·800-797-6210 Fax 708-339-1806 INCORPORATED CORONA, CA• (909) 737-6599 FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range • 3/8 thru 7/8 inch rod in l inch increments. Material -Carbon Steel Maximum Temperature -750°F Finish • Plain, Electro-Galvanized, and Stainless Steel. Order By -Figure number, rod diameter, rod length, and finish. ROD SIZE 3/8 1/2 5/8 3/4 7/8 MAX. REC. LOAD LBS, FOR SERVICE TEMPS, 650"F 750'F 610 540 1130 1010 1810 1610 2710 2420 3770 3360 {!'.'.'.!I ( i If I 14 I I 111 ! 11 i I; I 11 f,,,,, 111,1111, I',,: I !,Jli If ii ;t:J ::i, /i/ijJ)/1: FIG. 100 ALL THREAD ROD FULL LENGTHS Size Range -1/4 thru 1-1/2 inch rod in 10'-0" lengths. Material -Carbon Steel Maximum Temperature • 750°F Finish -Plain, Electro-Galvanized, and Stainless Steel. Order By -Figure number, rod diameter, and finish. MAX. REC. LOAD LBS. APPROX. ROD FOR SERVICE TEMPS WEIGHT SIZE 650'F 750'F PER 100 FT. 53 lNCOl'IPOl'IATf:D COAONA, CA• (909) 737.5599 FIG. 2 ADJUSTABLE RING HANGER 15 FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range -1/2 thru 6 inch pipe. Material -Carbon Steel, Mil. Galvanized to G-90 specification. Function -For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approvals -Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-l 71E, type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature -650°F Finish -Mil. Galvanized and Stainless Steel. Order By -Figure number and pipe size. PIPE SIZE ROD SIZE A B C A STOCK SIZE MAX. REC. LOAD LBS. C APPROX. WEIGHT PER 100 FIG. 2 FIG. 2 NFPA 1/2 3/8 3-1/8 2-5/8 1-3/8 16ga X 1 400 17 17 :o..,~-~Lll:;;;:>S/a.;;J;;(,aill&,;.,;:\i.~,l/2.,;c~il~ll~-:;,;i~i,,.19.s1,;i.l.J,,:,;i.,;~;~,-,APQ;,; 1},i,L2,.,:~1'222~i.il"iiJ1\.;;,'Wit 1 3/8 3-3/8 2-5/8 1-1/8 16ga X 1 400 18 18 ,.;.h.+L4:~:J:,S;$J~\iii¼J,9JL4'..,.J.l1:2.:,7/&:ei.!j;,]:iJ.Jtb,;0,1:J~si\JJ:1:lLs,L:.;:c:·._ .. ::;499_;;:,_.,,.;.:~-""';.._.;;;;}:.d2i;::Jii£t~~ 1-1/2 3/8 3-7/8 2-7/8 1 16gaxl 400 21 21 . :. ~,_.,; :. ' .1L2l.~:; '.,5i,\c'.,'!\'.iiL~;;;'..L~: ~;;,;JL~:1;X0l'.s:i:.~: .,~;jdgiJ~Kk:. ,.. ,L. • • • .. 4QQ ~"-;.,"'~' , . "L,&~-~i i,i/',;)~;.;;;~;].;lfuJ 2-1/2 1/2* 5-3/4 4-1/4 1-5/8 14ga X 1-3/16 600 41 40 :_3_.;,,; .: ,-,; : .JL?t~:.s!i,.§'.:•.L: ; ~:.,. c::,.;,,f J/s},:;c;,;-,, :}-ig4i,\i,:--,l1;i[¥1:i3/~.9~ . "' ·/\$9.0 . .-, ,;/t,,, _;;:; it:il.t:i::tJiii~.QJiii;\;;;;rJJ§iiliJ 3-1/2 1/2* 7-3/8 5-1/4 2-1/8 14gaXl-3/16 600 52 50 i 4, ': i ·: ,f:',_,: :. • $1P)•r,.•;:;;,;· 7/~18.!;;>::):il; ,i .•\·;'.,i,tiiilr:5<8:'IM;:-1): 1.4°a,xJ, l/4 : ;••. · ·1000·•··:•;. -.~, ,•.;_:•.;,,,,;; ;,,59. •.b~):~'''.i:'\~,;,i,,!#\;,~·:;p;9.•.i:i.. ,.,\i,· . .,..•"-"•~-.i:~o,,1'1>,l~~"J'u,-., _,....,\.._.w.:;rl..~, .... ;,..il.,~.1:¢ ... ,<.;".._.~~i.n;,.,,li_:,__;,>1.~-'-'---,.t,1, .• ,-'&i,~..,_:..&,c.~:.,,:,,,.,L.,:._.o •a.••·· ,:,,.~>.Cl<-'>,.r,,.__,.,~~~~•'-""'~•-"• -.-;..liat'loa.-~ ~IIJII 5 5/8** 9 6-1/8 2-1/4 12gaxl-l/4 1250 97 95 ·. f;i· .. ,. ·;,•<:.·!3/4~~:,-·::~,.~/8.'·' .. :;-.(>,'•l.J;?•···•)i. klll&1:,'\•.:c~:J?aa>: kJ:/4 .. ··• .;·., .125Q ·, .. ,•:.:· ,;,;:J~Q' .. :;;;;::,;;~.;,1::.,.<i-l~'.,,:1Qg,,f</ "'3/8" nut ia used when NFPA rod sizing ia; requested, "" l/2" nut is used when NF PA rod sizing is requested. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: GREYHA WK BUSINESS PARK Date: October 3, 2005 Location: 3220 GREYHA WK CT. Building: _D:::....:-E=---------=----------------System No. ..:..R:.::0::..:0::..:F:..._ ____ _ Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: LCH Drawing No. _3:......::O..:.F....:3;__ ____ _ Construction: t8J Combustible O Non-Combustible Ceiling Height ....:2::.:1:..-..:..0 ___ _ Ft. SYSTEM DESIGN ~ NFPA 13: LJ Light Hazard Ordinary Hazard Group LJ I lJ 2 0 3 r8J Extra Hazard 0 NFPA231 0 NFPA231C: Figure: Curve: D Other (Specify) □Specific Ruling Made By Date Area of Sprinkler Operation 3000 System TYJ1e Density .45 [8J Wet □Dry D Deluge D Pre-Action Area Per Sprinkler 100 S.F. MAX. SRrinkler or Nozzle Hose Allowance GPM: Inside 100 Make TYCO Model ELO231-B Hose Allowance GPM: Outside 400 Size ¾ K-factor: 11.2 Rack Sprinkler Allowance NIA Temnerature Rating 286DEG. CALCULATION SUMMARY GPM Required 1654.86 PSI Required 61.36 At Base of Riser ------------------" C" Factor Used: Overhead 120 Under ound 150 WATER SUPPLY Water Flow Test PumRData Tank or Reservoir Date& Time 8-3-05 I 1:50 PM Rated Capacity Capacity Static PSI 122 At PSI Elevation Residual PSI 116 Elevation . GPMFlowing 1500 Well Elevation 0 Proof Flow GPM Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD FIRE DEPT. rrnn II JI l y-<I.TAD A r,p Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized %Rack Rack D SingleRow D Conventional Pallet D Automatic Storage D Encapsulated D Double Row D Slave Pallet 0 Solid Shelving D Non-Encapsulated D Multiple Row D Open Flue SRacing In Inches Clearan1,:e From ToR of Storage to Ceiling Longitudinal Transverse Ft. In. Horizontal Barriers Provided greyhawk bldg d-e roof .45/3000 250 240 230 220 210 200 190 180 170 160 150 140 130 120 11➔ • 100 90 80 70 60 50 40 30 20 10 J..,, ,_,. ✓ u~al!-V ~ @. oY ~ 0250 500 750 1000 System Demand .. Sprinkler Demand 82.86 PSI ~dditional Flows Hose at Source Total Demand 86.72 PSI • /~ ,/ ..... ,_,. V 1250 1500 @ 1554.86 GPM 500.00 GPM 0.00 GPM @ 2054.86 GPM -• H0988 1750 Water Flow (GPM) Sigma Dynamic• Corporation 7700 Supply/ Demand Graph I I Margin Pressure 13.42 PSI Flow 1232.09 GPM 4 i ~ ~ I 2000 2250 Water Supply .. Static 109.80 PSI Residual 104.40 PSI Elevation 0.00 PSI @ 1500.00 GPM '-- ~ N1.85 2500 SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 1 greyhawk bldg d-e roof .45/3000 FLOW TEST RESULTS Water Supply STATIC 109.80 PSI RESIDUAL 104.40 PSI @ 1500.00 GPM CITY PRESSURE AVAILABLE AT 2054.9 GPM 100.13 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE ---------------- 100 63.31 43.20 11.20 31. 95 101 52.65 43.20 11.20 22.10 102 52.50 43.20 11.20 21.98 103 52.46 43.20 11.20 21.94 104 62.23 43.20 11. 20 30.87 105 49.94 43.20 11.20 19.88 106 49.80 43.20 11.20 19.77 107 49.77 43.20 11.20 19.74 108 61.59 43.20 11.20 30.24 109 47.78 43.20 11.20 18.20 110 47.65 43.20 11.20 18.10 111 47.61 43.20 11.20 18.07 112 61.29 43.20 11.20 29.95 113 46.12 43.20 11.20 16.96 114 46.00 43.20 11.20 16.87 115 45.96 43.20 11.20 16.84 116 61. 21 43.20 11.20 29.86 117 44.92 43.20 11.20 16.09 118 44.80 43.20 11.20 16.00 119 44.76 43.20 11.20 15.97 121 44.12 43.20 11.20 15.52 122 44.00 43.20 11.20 15.43 123 43.96 43.20 11.20 15.41 125 43.65 43.20 11.20 15.19 126 43.52 43.20 11.20 15.10 127 43.49 43.20 11.20 15.08 129 43.42 43.20 11.20 15.03 130 43.30 43.20 11.20 14.94 131 43.26 43.20 11.20 14.92 SUBMITTAL SERIAL NO:4144HY1 greyhawk bldg d-e roof .45/3000 SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR -------- 133 43.36 43.20 11. 20 134 43.23 43.20 11.20 135 43.20 43.20 11.20 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 8 OUTFLOWS AT 22 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 26 TO 36 PRESSURE -------- 14.99 14.90 14.88 1554.86 GPM 400.00 GPM 100.00 GPM 2054.86 GPM 86.72 PSI 0.00 PSI 23.26 FPS 10-03-2005 PAGE 2 SUBMI'ITAL SERIAL N0:4144HY1 10-03-2005 PAGE 3 greyhawk bldg d-e roof .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 131 135 2.703 L 8.00 C=120 PT 14.88 (135) Q 43.20 F==O F 0.00 PE 0.00 BN T 8.00 0.0054 PF 0.04 127 131DQ 43.26 2.703 L 8.00 C=120 PT 14.92 (131) Q 86.46 F=O F 0.00 PE 0.00 BN T 8.00 0.0194 PF 0.16 123 127DQ 43.49 2.703 L 8.00 C=120 PT 15.08 (127) Q 129.95 F=O F 0.00 PE 0.00 BN T 8.00 0.0413 PF 0.33 119 123DQ 43.96 2.703 L 8.00 C=120 PT 15.41 (123) Q 173.91 F=O F 0.00 PE 0.00 BN T 8.00 0.0708 PF 0.57 115 119DQ 44.76 2.703 L 8.00 C=120 PT 15.98 (119) Q 218.67 F=O F 0.00 PE 0.00 BN T 8.00 0.1082 PF 0.87 111 115DQ 45.96 2.703 L 8.00 C=120 PT 16.85 (115) Q 264.63 F=O F 0.00 PE 0.00 BN T 8.00 0.1540 PF 1.23 107 lllDQ 47.61 2.703 L 8.00 C=120 PT 18.08 (111) Q 312.24 F=O F 0.00 PE 0.00 BN T 8.00 0.2091 PF 1.67 103 107DQ 49.77 2.703 L 8.00 C=120 PT 19.75 (107) Q 362.01 F=O F 0.00 PE 0.00 BN T 8.00 0.2749 PF 2.20 38 103DQ 52.46 2.703 L 28.25 C=120 PT 21.95 (103) Q 414.47 F=T F 16.70 PE 0.00 BN T 44.95 0.3531 PF 15.87 28 38 2.703 L 0.83 C=120 PT 37.82 38) Q 414.47 F=T F 16.70 PE 0.36 NR T 17.53 0.3531 PF 6.19 PT 44.37 28) ------------------130 134 2.703 L 8.00 C==120 PT 14.90 (134) Q 43.23 F=O F 0.00 PE 0.00 BN T 8.00 0.0054 PF 0.04 126 l30DQ 43.30 2.703 L 8.00 C=l20 PT 14.94 (130) Q 86.53 F=O F 0.00 PE 0.00 BN T 8.00 0.0195 PF 0.16 SUBMI'ITAL SERIAL NO:4144HY1 10-03-2005 PAGE 4 greyhawk bldg d-e roof .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 122 126DQ 43.52 2.703 L 8.00 C=120 PT 15.10 (126) Q 130.05 F=O F 0.00 PE 0.00 BN T 8.00 0.0414 PF 0.33 118 122DQ 44.00 2.703 L 8.00 C=120 PT 15.43 (122) Q 174.05 F=O F 0.00 PE 0.00 BN T 8.00 0.0709 PF 0.57 114 118DQ 44.80 2.703 L 8.00 C=l20 PT 16.00 (118) Q 218.85 F=O F 0.00 PE 0.00 BN T 8.00 0.1083 PF 0.87 110 114DQ 46.00 2.703 L 8.00 C=120 PT 16.87 (114) Q 264.84 F=O F 0.00 PE 0.00 BN T 8.00 0.1542 PF 1.23 106 llODQ 47.65 2.703 L 8.00 C=120 PT 18.10 (110) Q 312.49 F=O F 0.00 PE 0.00 BN T 8.00 0.2094 PF 1.68 102 106DQ 49.80 2.703 L 8.00 C=120 PT 19.78 (106) Q 362.29 F=O F 0.00 PE 0.00 BN T 8.00 0.2753 PF 2.20 37 102DQ 52.50 2.703 L 28.25 C=120 PT 21.98 (102) Q 414.80 F=T F 16.70 PE 0.00 BN T 44.95 0.3536 PF 15.89 27 37 2.703 L 0.83 C=l20 PT 37.87 37) Q 414.80 F=T F 16.70 PE 0.36 NR T 17.53 0.3536 PF 6.20 PT 44.43 ( 27) ------------------129 133 2.703 L 8.00 C=120 PT 14.99 (133) Q 43.36 F=0 F o.oo PE 0.00 BN T 8.00 0.0054 PF 0.04 125 129DQ 43.42 2.703 L 8.00 C=l20 PT 15.03 (129) Q 86.78 F=O F 0.00 PE 0.00 BN T 8.00 0.0196 PF 0.16 121 125DQ 43.65 2.703 L 8.00 C=120 PT 15.19 (125) Q 130.42 F=O F 0.00 PE 0.00 BN T 8.00 0.0416 PF 0.33 117 121DQ 44.12 2.703 L 8.00 C=l20 PT 15.52 (121) Q 174.54 F=O F 0.00 PE 0.00 BN T 8.00 0.0713 PF 0.57 SUBMI'ITAL SERIAL NO:4144HY1 10-03-2005 PAGE 5 greyhawk bldg d-e roof .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Sununary From To GPM IN Devices Ft PSI/Ft PSI 113 117DQ 44.92 2.703 L 8.00 C=l20 PT 16.09 (117) Q 219.47 F=0 F 0.00 PE 0.00 BN T 8.00 0.1089 PF 0.87 109 113DQ 46.13 2.703 L 8.00 C=120 PT 16.96 (113) Q 265.59 F=0 F 0.00 PE 0.00 BN T 8.00 0.1550 PF 1.24 105 109DQ 47.78 2.703 L 8.00 C=120 PT 18.20 (109) Q 313.38 F=0 F 0.00 PE 0.00 BN T 8.00 0.2105 PF 1.68 101 105DQ 49.94 2.703 L 8.00 C=120 PT 19.88 (105) Q 363.32 F=0 F 0.00 PE 0.00 BN T 8.00 0.2768 PF 2.21 36 l0lDQ 52.65 2.703 L 28.25 C=120 PT 22.09 (101) Q 415.97 F=T F 16.70 PE 0.00 BN T 44.95 0.3555 PF 15.98 26 36 2.703 L 0.83 C=l20 PT 38.07 ( 36) Q 415.97 F=T F 16.70 PE 0.36 NR T 17.53 0.3555 PF 6.23 PT 44.66 26) ------------------112 116 2.703 L 8.00 C=l20 PT 29.86 (116) Q 61.21 F=0 F 0.00 PE 0.00 BN T 8.00 0.0103 PF 0.08 108 112DQ 61.29 2.703 L 8.00 C=120 PT 29.94 (112) Q 122.49 F=0 F 0.00 PE 0.00 BN T 8.00 0.0370 PF 0.30 104 108DQ 61.59 2.703 L 8.00 C=l20 PT 30.24 (108) Q 184.09 F=0 F 0.00 PE 0.00 BN T 8.00 0.0787 PF 0.63 100 104DQ 62.23 2.703 L 8.00 C=l20 PT 30.87 (104) Q 246.32 F=0 F 0.00 PE 0.00 BN T 8.00 0.1348 PF 1.08 35 l00DQ 63.31 2.703 L 28.25 C=l20 PT 31.95 (100) Q 309.62 F=T F 16.70 PE 0.00 BN T 44.95 0.2059 PF 9.26 25 35 2.703 L 0.83 C=120 PT 41.21 35) Q 309.62 F=T F 16.70 PE 0.36 NR T 17.53 0.2059 PF 3.61 PT 45.18 25) SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 6 greyhawk bldg d-e roof .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ------------------11 8 7.758 L 145.00 C=150 PT 80.02 8) Q 572.02 F=GV,T F 58.94 PE 0.00 LU T 203.94 0.0025 PF 0.51 4 ll 7.758 L 120.00 C=l50 PT 80.53 11) Q 572.02 F=T,GV,EE F 72.53 PE 0.00 LU T 192.53 0.0025 PF 0.48 PT 81.01 { 4) ------------------9 8 7.758 L 259.00 C=150 PT 80.02 { 8) Q 1135.40 F=2GV,2EE F 39.26 PE 0.00 LU T 298.26 0.0089 PF 2.65 12 9DQ -978.02 7.758 L 80.00 C=150 PT 82.67 9) Q 157.38 F=GV,T F 58.94 PE 0.00 LU T 138.94 0.0002 PF 0.03 3 12 7.758 L 215.00 C=150 PT 82.70 12) Q 157.38 F=T,GV F 58.94 PE 0.00 LU T 273.94 0.0002 PF 0.05 PT 82.75 3) ------------------10 9 7.758 L 160.00 C=150 PT 82.67 9) Q 978.02 F=GV F 6.04 PE 0.00 LU T 166.04 0.0067 PF 1.11 1 10 7.758 L 326.00 C=150 PT 83.78 10) Q 978.02 F=2EE,4GV,T F 104.24 PE 0.00 LU T 430.24 0.0067 PF 2.88 PT 86.66 l) ------------------7 8 7.758 L 382.00 C=150 PT 80.02 8) Q 347.44 F=T,GV F 58.94 PE 0.00 LU T 440.94 0.0010 PF 0.44 6 7 7.758 L 40.00 C=l50 PT 80.46 7) Q 347.44 F=O F 0.00 PE 0.00 LU T 40.00 0.0010 PF 0.04 5 6 7.758 L 157.00 C=l50 PT so.so 6) Q 347.44 F=GV,2EE F 33.22 PE 0.00 LU T 190.22 0.0010 PF 0.19 4 5 7.758 L 320.00 C=150 PT 80.69 5) Q 347.44 F=GV F 6.04 PE 0.00 LU T 326.04 0.0010 PF 0.33 SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 7 greyhawk bldg d-e roof .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 3 4DQ 572.02 7.758 L 266.00 C=150 PT 81.02 4) Q 919.46 F=2GV,EE F 25.67 PE 0.00 LU T 291.67 0.0060 PF 1. 75 2 3DQ 157.38 7.758 L 75.00 C=l50 PT 82.77 3) Q 1076.84 F=GV F 6.04 PE 0.00 LU T 81.04 0.0080 PF 0.65 1 2 7.758 L 314.00 C=l50 PT 83.42 2) Q 1076.84 F=2GV, T, 2EE F 92.16 PE 0.00 LU T 406.16 0.0080 PF 3.25 PT 86.67 1) ------------------27 28 6.357 L 12.00 C=l20 PT 44.37 28) Q 414.47 F=0 F 0.00 PE 0.00 FMl T 12.00 0.0055 PF 0.07 26 27DQ 414.80 6.357 L 12.00 C=l20 PT 44.44 ( 27) Q 829.27 F=0 F 0.00 PE 0.00 FMl T 12.00 0.0198 PF 0.24 25 26DQ 415.97 6.357 L 12.00 C=120 PT 44.68 ( 26) Q 1245.24 F=0 F 0.00 PE 0.00 FMl T 12.00 0.0420 PF 0.50 24 25DQ 309.62 6.357 L 6.00 C=120 PT 45.18 ( 25) Q 1554.86 F=T F 31.43 PE 0.00 FMl T 37.43 0.0633 PF 2.37 23 24 6.357 L 45.75 C=120 PT 47.55 ( 24) Q 1554.86 F=0 F 0.00 PE 0.00 FM T 45.75 0.0633 PF 2.90 22 23 6.357 L 20.50 C=120 PT 50.45 ( 23) Q 1554.86 F=2E F 25.14 PE 8.02 FR T 45.64 0.0633 PF 2.89 21 22DQ 100.00 8.450 L 7.00 C=l40 PT 61.36 ( 22) Q 1654.86 F=2E F 63.24 PE 0.00 UN T 70.24 0.0134 PF 0.94 20 21 7.758 L 95.00 C=l50 PT 62.30 ( 21) Q 1654.86 F=T,4EE,E F 134.44 PE 4.66 UN T 229.44 0.0178 PF 4.08 COMMENT: elevation difference from flow tes taken here 15 20 7.758 L 10.00 C=l50 PT 71.04 ( 20) Q 1654.86 F=4E,DCA F 108.72 PE 0.00 UN T 118.72 0.0178 PF 2.11 8 11 DOUBLE CHECK DETECTOR ASSEMBLY 3.83 SUBMITI'AL SERIAL NO:4144HY1 greyhawk bldg d-e roof .45/3000 Location Flow in From To GPM 8 15 Q 1654.86 0 1 Q 2054.86 Pipe Size IN 7.758 UN 7.758 UN Fittings & Devices F=T,GV,E L F T L F T Equiv Friction Length Loss Ft PSI/Ft 85.00 C=150 86.12 171.12 0.0178 1.00 C=lS0 0.00 1.00 0.0266 10-03-2005 PAGE 8 PT PE PF PT PT PE PF PT Pressure Summary PSI 76.97 0.00 3.05 76.20 86.69 0.00 0.03 86.72 15) 8) 1) 0)