HomeMy WebLinkAbout3210 GREY HAWK CT; ; AS050203; Permit---·······• .. -• ......... . 10/31/24, 3:38 PM AS050203 Permit Data City of Carlsbad Sprinkler Permit Job Address: 3210 GREY HAWK CT Permit Type: SPRINK Parcel No: 2210150200 Lot#: 0 Reference No.: PC#: Permit No: AS050203 Status: ISSUED Applied 10/5/2005 Approved: 11 /22/2005 Issued: 11/22/2005 Inspector: Project Title: BLDG. A FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: LIFEGUARD FIRE PROTECTION STE F 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 Fees($) 1,150 Add'I Fees ($) 0 Owner: PALOMAR FORUM ASSOCIATES LP C/O DAVIS PARTNERS LLC 1420 BRISTOL ST N #100 NEWPORT BEACH CA Total($) 1,150 Balance($) 0 about: blank 1 /1 JUL 19 2005 1:37PM HP LASERJET 3200 15of[)cl03 CARLSBAD FIRE PREVENTION DIVISION Permit Application Fom1 A. Check or fill in pertinent information .for typ~ of permit you are submitting. AS-A.uto11llltlc Sprinklers (Check offo,pe of plans being submitted) • X New System-How many riseisllevcls? __...l _ __ tenant 1-nprovemerit __ Residential -a<,w many systeDl9 and/or buildings? __ __ Underground for approval. __ Undergrf?und.includtd for reference only FA_, Fire Alarm 25 Devices or less --Over 26 devices __ # of devices __ _ TotaJ Fees __ _ FS-Fi%ed Systems (Cltck One) . Hood & Duct, Special Chemical Agent Suppression. System, Standpipe, Spray Booth or Appliance. Failed Inspection ree is $65.00. B. Naqio of Project: &'(14'{ Hl\-(.ut'.. §}St tJI=$$ ~a_~. TotalFee;s --- C. Addres.19fjob site: f;l.06,., A. /'32l0 Gitvt-lAW~ q: Suite# -1 Building Permit #J. CB O 5 3 ;2. 3 Z D. Contractor Infonnation . Name/,d/FGG-(JA{lD Ft/le. /J/lo TGc.TtoAJ, IAJ.,C. ~. • Adcfi'.ess Uo s= T&1 /?t-6.. @ts , DI?, #-E City,State,ZipOC£lt/l)StD€. I g. qZo.S-b • PhoneJbo-Soh-qqq I FAX160·;.f$o6-4Bl :3 Kind of License and N11D1ber CI b -1 ~2-, 4 s-1 Exp. Dato / -31-D] Do you currently have Certlilcatl! of lnsuraocc on file with tho Firo Dop~ ·~No /J. .. Do you currently have a business· license on file with the City of Carlsbad? CliJ or Nop~ . ' . I} . ~ • • 1,;-,;.,✓ • Signature~~ Dato /0-f~O';;, Please atlmate at least 10 lnuineu days ror pla~ review comments and/or approval. We wB1 contact you ~ telephone when tbe plans •i;e ~p,roved/disapproved. . Thank you! . • · /JI~ -g-·· fj)t,, ff/S/1~ __ . . p.2 09/22/2006 11: 31 7605979527 B4/27/2BBF, 03:52 Contractor's Mate,·lat and Test ·eert\flcate for Undergro1.1nd Piping PAOCIDU~• . Opal' l!elllP"°IOI DI wr:n, il\.lC,lk,i, ana,1111 nll be m.d• rt1 "'' --1.-cw'II •• ,, ... r-1«~, .. ~d Wllf\etttd i,, .,, IIM'llr'II ~e,llftl■lhlo, ~, -r.e,, .., .. 11, :llfftotld 11t1C1 SVl'tm lttl in lfJNICl9 11.-~,·, P!~Dnfltl llnally lllV• Iha IOll Adtlltl.-111111 ti• lllld out llltd tl1tnlld by b0tll ,.p!ISl<lll11WS, QOpitt -...w lie Clf'l!jllll!d !or 11pprov11111 nulhorllll!!t. own,!9, 4l'ld · IIOlllraclCII, It Is undll'l'l,od 1h11 OMolllr"S llp!lltt~'• lv,imHt In na wly p!IJudiCIII •IIY Cl~.im CIJ!lllflll llOMIK101 1111' l'avlt1 ffl(l11114al, ptlCI! ~l'lffll4lnllMI, ar ftllu,1 te co,nply wllll 11pp!'O"lr\g ■UV'larlly'a ~•nll or laaal 111t11n111--. ,,. P1Qp1r,y11■ftlt (;a,p_"'( 1;~""~~U~N~ PA (2-~ ·,· , I 0110 4-i~-- PIO,Orly ■ddmt ..,,,,~\Q C?B:6'{ \.tP,.WlL c:r, ~)\L OlblG A Plans ll'lltrucliona LOGUDn IJl\dlligr!Nl'III pjptslrJrJ JDlnll TIIII dllerlpliCII AaalPfl(t ti, IIPP/Olil"!I ,111Mr11let (IIAl!IH) ~ ....... ,~c)_E, '>"s P~r:'1 Add111n ....., ___ ---------·------~---·•·---... ~----------•--➔ 1n1=tllii.11an ct.nlo,,n, lo lectP11d ptll'IJ • QO VII Cl No lqulllffilfll\l;vdlupp~ ""'l5'ij v.a O No II no, ltatt ~ vlaliofl) H• p■llon ;n ol\ll'III ot llrt ■Q!Jt,fflflll1 hlll'i lnstNCltd IS ID loDIIIDn Cl llD!llnll '111~•11 llld DIINI llld 11111111■nenc.1 af IN• ntw l!liJ(lffll!lil? 11 no, tlCPllllr, 0 Na i-----------·------------·-·-·---------------~ H■v■ r:op1t1 Ill 11pp,i,p,,.te lnStn,cll-a11d cat'II and m;lit'\ll!ln■nca i:,,tr,tllNl'I IIILIDftD19mi!lll■t II no. o,ci,!1ln '---------------·---------·-·---------------JollM I'll'~~ d Wllll'IONI" cl■fflpld, 11r:111111111. DI l)llltlk■O In ICO)fdlftlle NIii t§f' !\ 2,\ ■l■"e~rcl II no, •JIPI•~· JS<l Ylt NPF~'~~:~~•:1c:::iii•o • '\IY.~ □ Nil II no.e,q,k\~• ----···---------------..,,----------------------4 Hew 11u,111n 1 lavr _. otlltln•d I T1'raugt, lll!lltlype op■""111 Q_l'llbllc: •IIM!r Cl 1mlll or ltSel\'Dr □ 111111 pul'l'lp .J.? Hydral'li D11II . -jii:':°Opan P'P• b1d.i,,111~lll"cl 1cca,dlllg ID (:'h kl f) . 11•~ 1')' (eomP1Jr,y) ~• □ No 11 l'IO, ~pl•~• , ,, flGVU ,.0.10.1 Smnp1e (lr Conll'actor, M■tmaJ ll:lcl TIMI Certificate Eor li11detpvtmd Pipi."1- 09/22/2006 11:31 94/27/298& 03:52 7605979527 !;19-562-1685 LUSARDI KTA CONSTP.UCTIDN INC PAGE 03 PAGE 15/29 AIOV!011.0UN1> JIJPt Ai'-'D flTTI~GS ~aide All "I"' 111·, :1,11:i,eLllld piping ¥10tl1tiall~ te!llld 11,I JalnlS~lll•4d IIJII _.1a.__, p,l fOI t-l'lai,, iBJ 'tltl 0 No '1111tl ,me11ntl--"' "1NIIIIM! l, . l.Nhegt _ . glllont 110\lr,. ... -. -MD•l•·~Ul· . -: "'"'"' -J_ halltS Hydrlnl•· Nu111JIIIP lr,elalld . I '!yp•llf'dl'lllkc I~" all"ra•~ao-= :r~es □ jllg Wllll•cc,iAMI ,_,.1411 -de IIOl!III ' •. ,mv., □ N11 If "'· lllb ► r111111n ,. .. catll'l'III .• llllvH ~ Ye, HOS4 lht•t llllll ol nr, dl!IPlrlml!III ~11,,.~dolll tnd ttydra"t' lmn:h•"ll'~t)la ~ 0 Nit ltla■I al I fl dl~nl INIWlll"II IIIIIII Date ll!lft n SIJrvlOf lltmam ---.... -·- D11 1.,t~-r-51 ~ "lf,ltt lCJfo ,IL.. ' ,_ .. ~--=~ ~ C:.OrJ St°ti.~ gc,J Slgn11u,-• F~~,~~ 1'ttsw1t1M1111Rlb~ -·-: [~•~5~f-!DP/~ Ot: For;!.': '.~ ,,,de~~ I ~H1; /OL Addlllonll tlll'IIIINtlon and ~,1111 ,. (~PA. 24. 2r:r111!) FIGtJltE 10.J.D.l Cami1:t111f (l)'"'fhir amo\11ll or leukp.gc at the joil"t., shall 11ot exc111:d i qVllr (l.89 L/ht) per l 00 p.•kl!ts or joia~, lrrupr:c11ve or pipe tUatnetet. ('2)-niumount ofb\age s11•clficd in 10.10.2.2.fi(\) shall T)e pen,\itted to be ;nc1 eased by l .fl or. ( 3D ml) pet ini:;h val',le dlamtl'CI' per h"'-1? fqr c•cft metal-,ea~ed \iiilvc isol:atlng 1hc 1.e1uectlon. •• (J) 'tf d'l' bane, .~ydra1113 •re te11t.cd wtth the fflGln valve open so the h,idnnturc-under pru1u.re.11n :uld,tlonal sn or,/ min (150 mlhnin) ;,{lc•bge llhall be permitted f'>f w:b hrdnnt. (4) The anount of le:,~ in bwied. pipi,,i.S sh11ll be ffll!I\• suHd :at the ~cciF ed tat pmsure by purnplng rrom a calibrated cc,nra1m)(', Qapter 1l Hydrmillc CaleuJatioa.f 11-1" Oa1c:iatatlom bl f.:aglis'h Ulllts, Pipe: t.ricuon losm shall be de~etn1lnircl bct1.,d C•" the HMm-W1tti!lrru (om,uhl, :u .fot. tew1: whcrr:: P. ~ .frlr;t,i('"' 1 rulstani:c (psl/f, of. pipe) t'2 ._ flo;~ (~m) C ,. trictic,n lo~s CQeffl.del.'I~ 11. .,. actu~1 internal tlitll'lct,r 10f~ipe (in,} 11 .! c~~rfons ill SJ u.ru. pjpe frlcdon lo~~II matt be ,,~ tmr,ir,ed b:t~<I on. the Hlt.~-'Wl.lli■fflll formula In S.l units, 115 f'ollow5: whi:re: , .. • frictirnnl rnis~I\CC (bft,:/m of pipe) Q.,.. 'S fk.w IL!mia) C • Mul,;,n l,,lll etiefticitDL "'" = :1.c11.~1 inrcrnal cU•rneter of pipe (mm) Ch11p1er I 2 Abovep,und Plpe and Jittinp t 2.1 i;,.,1m11. Al>11Vtpund pipe anc1 flmnp 1haff comJ)ly with tlif. tf•vlicabl, 1etdQn1 DI Chapters 6 and 8 af NJJ>A n, 09/22/2006 11:31 7~05979527 LUSARDI 1~190 JNSf.AJJ.ATION OJ SPRINICLER SYSTDIS As l~z~.B Cd o532'3Z.. Contractor•• Miterlal and Test CeriHlcate ~r Aboveground _,lplng PROGIDUM . , . •. • • UpoftOD1,4HIIGrt arwortc, lnlpdan'llndtallllhtillNIMdt-lMOOl ...... ..,WUM ■nd ...... byan ..... ' ~•~.,._--' lbeaat1■et9dend..,.~ln-a·~mnlrlclotl1.pa...,_11nall'I.._IM.jclh. Ace,,._·11111••tliecl aut ■ndatgnlcl~bclCl'I ~. CoplN llhlllbl p,aplladt:irapp"""'101Ulharlllia, CMrllf9, and • OllfflllllltDI', 111■ undal■lood 1w CIIVMr'I ~·· ..,.. .. 1n no-,.-111111ca-,,, Cllllm ■gthl~ l:ir r.uay ........ poar ~IP. or llllln,IO ~ ~.APll'Ml8 llihlltlr'• niqialnman11• IDall onllllNl■I. • 11-ldllli~IDIWlpl«lplW ..,_."9ed ........... I no, Gpl■ln dlvlllOt• • ~pellGII In~ al !n llqll(pmant llwn llllllmld M ID_... al GOnllvl --anll G1119 and ffi■I~ ollll■nw~ lfllO, .... lfl. • MM_. al ~~belnltllan lle~"'i ■l!'7 1. ~ compon11111 ln1Wlldlall■". I. 0CAM llnd ,.....,__-lnllnlafalw a. NPPAZli □ ND □ ND D No D No •• •· •' ~ ·n-U W.. .lf7 ,!) ', -,I "·, .. LI ·-;t • TWPI Glplpe ___.-----..s.1~~--_._.'--_ _,g~1__,,......,._...:,...i ..... ,11;1._.::::...-,t;.;;.---......,-Type.dMIQI ____________________ ...,... ____ ___ --.-ot .... lnllanot I ... Maka 'Moclll ftllnull1 8aGollCII pal 11.,.,...-.. 1 Mlililulwdt,ilm Mrnii lnlliaGlllr'I.IIIIGUMicllDll ta.,.i 1 NFM1i OIIIV,■qllnl II,-eo--aancl~III..,_._._ I I ·e.11111 no. M■la -'-· ---.. --. ,,., -point ...... ' .. ,.,,.... ... ml ·. RGURB 11.1 Coiltncto~• Ma..W •• "1ml CatUlcacia tor AIMwepnmd ...... aooz,~· ~lllnelDapa··· ~" , .. CIIIMIDllan ' o·oD ·I I Y,/j .. ... , ............ Alan ....... • ..... . ... PAGE 04 A- 09/22/2006 11:31 : : •. ··--.---•·' [,....~ x-.., __ .I\ .~ ,,, 'IV! dNafplon - CUloull (cha) : JIICtJBJt lC.I .. 7605979527 Ll..JSARDI PAGE 05 SYS'l'EMSACCEl'TANCE □v.-□NalDataclng~~ •□-0 No Doea..,. opera111 fn:1111.,. manvlltrfp, ntmoM, or bath wnlnil Malltlnl'I II,.,_ 111 UDllllbl1 ~ llt Ndl dnd forlNln,'I C:J "'' □ No ,._, .,,,., .. , ..... M■a .' Model Doll 11oh cllaull oparu lllfllMllan loM ■lllm'r. DoiaNchdnulqpe-■ :~rtl ... 7 ••• Mulnalm 1111■ It ..,.. ....... , VN I N, Y• '. I Na Mint.a I l!llciand■ I I I . L-iiiin. ...... and l!lallng S.llcp,.-.ui. fllll6,ej ,....,,. Fillwlldl llldlool' ~ ,, ("""'1lt " " 1nI11 llilll I . 0Ulllt c,.i, 1111111(1111) I OUllet,(JIIII FlcfW(pl) I I • • Hvcf!Mlllo: ...... ~ 1h11 bll made al 111111 IHI lh1n ~ pal (1L8.Hf1 tar 2 hClln otlll flll (1.4-, .--,111a in-1n1n-a11&opa1 (10.211111') tor thaurt. DlhnnllllcfrH!pewi. ~ ~• w Ill open dt,tlng Ille 11111 ID prMnt dlmlge. All lbcMtfaund piping 11...-lh■H be IIDpplNI. • ~blllh 40Pll 42,7 bll" ■Ir Pf'IIIUl9 Ind 111e■-n-.wtlld!Ml■II nol ._.1141 pal (0.1 -, TNI p-lllnlal atl'IOll'f'llll-.19rllWl ancl alrp ....... andmHIU198I-Jnal!IW llq\ WIIM ... 1\tJIIIJCl,11111,)lnM' ...... • ., • . . . Do )'OU C111111t H hi tp,111,.,_iiv,..,_., 1tM1t acldlfvN and~ llhlmloall, NAlm ._.. 11r ........,_ d IOdlum llllcl!le, bdna, DI 111111, lll>IIUIIMl1 damlmlt M nat UUd IDr lHllna ~ml er .......... , D 'Ail D No DNIII Aallllfllil al Dauo-IDcalld ,-_., • • IAellclual pNNIIN wllh lllhll lh-• • 111111 lupply tal Cllltndan: lL/L_ ml(~•" · oonl"lldlan .. nWIM:/ / ~1111111 t'c. r.w II~~,__._ n ulld In CIDIIDIWII, /.liZJ Yal □ ND ........... ,..,. ......... 11-. ......,mmp..._,, 11,-e ... Do,vlf otrlry ■11hellfllfnldwearnc1Drfl■I wlldlnl PIDCaeluMoomply wllll .,_ llqlll.....,. 1111 II fNII AWi 11.1? · , • ' Do JD11 Glflly ll■t ,all 11M I cmlrd IIIU. » Mlln !flat all CUIIIUlll j~.,. l'llllftwed7 .. □.NI - " 1$-191 09/22/2006 11:31 7605979527 LUSARDI l·S-192 INSTAUA'llON'Of'SP~Rft'STEN! Namepl ... p!Olllded \',-•,•= ... ::• _,)•.~-~ ~ V.,,.,£] fig,: !''"•' •.• ·.,.·, ,'•,:?,,, .. -11· Dill• laft In llilfNICI WIii II contral VIIYN op■1t ... •'•' '' .. :• '•°'' ,; I',!•· ; r ' ••• 'l, ,: • ., •_' .;1~1.'. ~•,•• •, :••~I . • · ;,,.,.,., ., .. ,., ,,·.~• wllne..-111¥· ,, .• ,,, Slgn■lure■ ·:;for pn:1 '• I. •.',!. . DIiie :;-·····, ,. .q .~.a2. -of;;,--• :-...... •······ '• .. ~-a· -~; 1-i...::~&; Addlllonll capl■t~.~~ ~~ ... _ ... . j ! r·· .-.;, 1, , • ·: • -: .:, • i ·: ... t·, • • 1:1 :11 :•, "·: :i• ·, •• :: •• ,· ,· .-·~ . , ,:-,1•1; !.~.-.ir.r. • ·!" • ':-~: -~ .,~::": :' ; ' '. ·, ' .. , .• ~ :1· .,, • •:: '. ' 1' •, ... • ' • ., .. !."·-•f -:·· .. ·1. , .... /•:,: '. -~ .•· ·••\.'·,:.·.•~•:, •,<' ::\.·\, '., .' (1',,~:•,1.t,1:1,~:l~/-~ :•,•-:·•,•i··. I .. ,•~•,•'.~'·"-:'· :!:,·•i",'•,' ~-ij1,.1:· ... :,;-,•:. I::,:·. '. • 'I ~,!'!'_:'•'. I:' •• ,..l:•\'", ''\ : '' :,-!;-,:. .•• b ••• • ·:•.,f"..:w•n~ ',t~ ;.,:j",1 i{•\'.,I' , •.l,t. • ·,'.,, ·~::• ;:. ,:.-:);' t'•l: .. 1.•·,: L • \t ~ ·;:•.._.·' ( :_ ! \' I •• " : • • I ';.I; • : ~ '• '.' • ; .. :·':, .. ,"!: ..... .. . ' ... • •' .. ., ... '' '., . .. . ,· ~ . PAGE 06 '_\ . .• • i\ :.-' •.. ,:, LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: OREYHA WK BUSINESS PARK Date: October 3, 2005 Location: 3210GRaYHAWKCT. Building: ...,;A~---------------------System No. ROOF Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: LC;;...,,.H,.,__ ________________ _ Construction: 181 Combustible O Non-Combustible DrawingNo. 30F3 Ceiling Height 21-0 SYSTEM DESIGN NFPA 13: Light H87.afd Ordinary Huard Group l 2 3 Extra Huard 0 NFPA231 0 NFPA231C: Figure: Curve: 0 Other (Specify) □Specific Ruling ____________ Made By Date Area of Sprinkler Operation 3000 System Type Density .45 cg] Wet D Dry D Deluge D Pre-Action Area Per Sprinkler 100 S.F. MAX. Sprinkler or Nozzle Hose Allowance GPM: Inside l 00 Make TYCO Model ELO 231-B Ft. Hose Allowance GPM: Outside 400 Siu ¾ K-Factor: 11.2 ___,;________ _.;;....;_;;;__ _____ -I Rack S rinkler Allowance N/A Tem ture Ratin 286 DEG. CALCULATION SUMMARY GPM Required _l __ S_31_.4_1 _____ PSI Required _4_2_.50 ______ At Base of Riser "C" FactQr Used: Overhead 120 Unde und 150 WATER SUPPLY Water Flow Test pnmpOata Tank or Reserv2ir Date&Time 8-3-05 I 1 :SO PM Rated Capacity Capacity Static PSI 122 At PSI Elevation Residual PSI 116 Elevation GPMFlowing 1500 ~ Elevation 0 ProofFlow GPM Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD FIRE DEPT. r-.-.;...,:,._. JI 111 •l 'STOR A.tl~ Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized %Rack Rack D SingleRow D Conventional Pallet D Automatic Storage D Encapsulated D DoubleRow 0 Slave Pallet 0 Solid Shelving D Non-Encapsulated D Multiple Row D Open Flue Spacing In Inches Clearance From ToR of Stom~ to Ceiling Longitudinal Transverse Ft. In. Horiz.ontal Baniers Provided GREYHAWK BLDG A ROOF .45/3000 250 240 230 220 210 200 190 180 170 160 150 140 130 120 110• 100 ~ • -· 90 80 70 60 50 40 30 20 10 ../ J \ft.y,\l.¥'° ~ -... .,_DI 0250 500 I, ,,,,.,, 750 1000 System Demand .. Sprinkler Demand 63.39 PSI Additional Flows Hose at Source Total Demand 68.70 PSI 1250 1500 @ 1431.41 GPM 500.00 GPM 0.00 GPM @ 1931.41 GPM no 1750 water Flow (GPM) I Sigma Dynamics Corporation 7700 Supply / Demand Graph I Margin -Pressure 32.48 PSI -Flow 2556.73 GPM ~ ~ ,,..,. 't1 I 2000 2250 Water Supply .. Static 109.80 PSI Residual 104.40 PSI Elevation 0.00 PSI N1.85 2500 @ 1500.00 GPM SUBMITl'AL SERIAL NO:4144HY1 10-03-2005 PAGE l GREYHAWK BLDG A ROOF .45/3000 FLOW TEST RESULTS Water Supply STATIC 109.80 PSI RESIDUAL 104.40 PSI @ 1500.00 GPM CITY PRESSURE AVAILABLE AT 1931.4 GPM 101.18 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE ------------.... --- 101 43.54 41.99 11.20 15.11 102 43.27 41.99 11.20 14.92 103 43.14 41.99 11.20 14.84 104 43.10 41.99 11.20 14.81 106 43.61 41.99 11.20 15.16 107 43.34 41.99 11.20 14.97 108 43.21 41.99 11.20 14.89 109 43.18 41.99 11.20 14.86 111 43.88 41.99 11.20 15.35 112 43.60 41.99 11.20 15.16 113 43.47 41.99 11.20 15.07 114 43.44 41.99 11.20 15.04 115 55.50 41.99 11.20 24.56 116 44.21 41.99 11.20 15.58 117 43.93 41.99 11.20 15.39 118 43.80 41.99 11.20 15.30 119 43.77 41.99 11.20 15.27 121 43.29 41.99 11.20 14.94 122 43.02 41.99 11.20 14.75 123 42.89 41.99 11.20 14.67 124 42.86 41.99 11.20 14.64 126 42.75 41.99 11.20 14.57 127 42.48 41.99 11.20 14.39 128 42.35 41.99 11.20 14.30 129 42.32 41.99 11.20 14.28 131 42.49 41.99 --11 .20 14.39 132 42.22 41.99 1.20 14.21 133 42.10 41.99 11.20 14.13 134 42.06 41.99 11.20 14.10 SUBMI'ITAL SERIAL NO:4144HY1 GREYHAWK BLDG A ROOF .45/3000 SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR -------- 136 42.42 41.99 11.20 137 42.15 41.99 11.20 138 42.03 41.99 11.20 139 41.99 41.99 11.20 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 16 OUTFLOWS AT 22 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 26 TO 36 PRESSURE -------- 14.34 14.16 14.08 14.06 1431.41 GPM 400.00 GPM 100.00 GPM 1931.41 GPM 68.70 PSI 0.00 PSI 19.36 FPS 10-03-2005 PAGE 2 SUBMI'ITAL SERIAL NO:4144HY1 10-03-2005 PAGE 3 GRBYHAWK BLDG A ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Sunnnary From To GPM IN Devices Pt PSI/Ft PSI 134 139 2.703 L 9.33 C=120 PT 14.06 (139) Q 41.99 F=0 F 0.00 PB 0.00 BN T 9.33 0.0051 PF 0.05 129 134DQ 42.06 2.703 L 9.33 C=120 PT 14.11 (134) Q 84.05 F=0 F 0.00 PE 0.00 BN T 9.33 0.0184 PF 0.17 124 129DQ 42.32 2.703 L 9.33 C=l20 PT 14.28 (129) Q 126.37 F=0 F 0.00 PE 0.00 BN T 9.33 0.0392 PF 0.37 119 1240Q 42.86 2.703 L 9.33 C=120 PT 14.65 (124) Q 169.22 F=0 F 0.00 PE 0.00 BN T 9.33 0.0673 PF 0.63 39 119DQ 43.77 2.703 L 1.08 C=l20 PT 15.28 (119) Q 212.99 F=O F 0.00 PE 0.00 BN T 1.08 0.1030 PF 0.11 PT 15.39 ( 39) ------------------133 138 2.703 L 9.33 C=120 PT 14.08 (138) Q 42.03 F=0 F 0.00 PE 0.00 BN T 9.33 0.0051 PF 0.05 128 133DQ 42.10 2.703 L 9.33 C=l20 PT 14.13 (133) Q 84.12 F=0 F 0.00 PE 0.00 BN T 9.33 0.0185 PF 0.17 123 128DQ 42.35 2.703 L 9.33 C=-120 PT 14.30 (128) Q 126.47 F=0 F 0.00 PE 0.00 BN T 9.33 0.0393 PF 0.37 118 123DQ 42.89 2.703 L 9.33 C=l20 PT 14.67 (123) Q 169.37 F=0 F 0.00 PE 0.00 BN T 9.33 0.0674 PF 0.63 38 118DQ 43.80 2.703 L 1.08 C=120 PT 15.30 (118) Q 213.17 F=0 F 0.00 PE 0.00 BN T 1.08 0.1032 PF 0.11 PT 15.41 ( 38) ------------------132 137 2.703 L 9.33 C=l20 PT 14.16 (137) Q 42.15 F=0 F 0.00 PB 0.00 BN T 9.33 0.0051 PF 0.05 127 132DQ 42.22 2.703 L 9.33 C=l20 PT 14.21 (132) Q 84.37 F=0 F 0.00 PE 0.00 BN T 9.33 0.0186 PF 0.17 SUBMI'ITAL SERIAL NO:4144HY1 10-03-2005 PAGE 4 GREYHAWK BLDG A ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length LOSS Summary From To GPM IN Devices Ft PSI/Ft PSI 122 127DQ 42.48 2.703 L 9.33 C=120 PT 14.38 (127) Q 126.85 F=0 F 0.00 PE 0.00 BN T 9.33 0.0395 PF 0.37 117 122DQ 43.02 2.703 L 9.33 C=120 PT 14.75 {122) Q 169.87 F=0 F 0.00 PE 0.00 BN T 9.33 0.0678 PF 0.63 37 117DQ 43.93 2.703 L 1.08 C=l20 PT 15.38 (117) Q 213.81 F=0 F 0.00 PE 0.00 BN T 1.08 0.1038 PF 0.11 PT 15.49 ( 37) ------------------131 136 2.703 L 9.33 C=l20 PT 14.34 ( 136) Q 42.42 F=O F 0.00 PE 0.00 BN T 9.33 0.0052 PF 0.05 126 131DQ 42.49 2.703 L 9.33 C=120 PT 14.39 ( 131) Q 84.91 F=0 F 0.00 PE 0.00 BN T 9.33 0.0188 PF 0.18 121 126DQ 42.75 2.703 L 9.33 C=120 PT 14.57 {126) Q 127.65 F=0 F 0.00 PE 0.00 BN T 9.33 0.0400 PF 0.37 116 121DQ 43.29 2.703 L 9.33 C=120 PT 14.94 ( 121) Q 170.95 F=0 F 0.00 PE 0.00 BN T 9.33 0.0686 PF 0.64 36 116DQ 44.21 2.703 L 1.08 C=120 PT 15.58 (116) Q 215.15 F=0 F 0.00 PE 0.00 BN T 1.08 0.1050 PF 0.11 PT 15.69 ( 36) ------------------35 115 2.703 L 1.08 C=l20 PT 24.56 (115) Q 55.50 F=O F 0.00 PE 0.00 BN T 1.08 0.0086 PF 0.01 PT 24.57 ( 35) ------------------109 104 2.703 L 9.33 C=l20 PT 14.81 (104) Q 43.10 F=0 F 0.00 PE 0.00 BN T 9.33 0.0054 PF 0.05 114 109DQ 43.18 2.703 L 9.33 C=l20 PT 14.86 (109) Q 86.28 F=O F 0.00 PE 0.00 BN T 9.33 0.0194 PF 0.18 SUBMITI'AL SERIAL NO:4144HY1 10-03-2005 PAGE 5 GREYHAWK BLDG A ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 39 114DQ 43.44 2.703 L 8.25 C=120 PT 15.04 (114) Q 129.72 F=O F 0.00 PE 0.00 BN T 8.25 0.0412 PF 0.34 29 39DQ 212.99 2.703 L 0.83 C=120 PT 15.38 39) Q 342.71 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2484 PF a.so PT 24.24 ( 29) ------------------108 103 2.703 L 9.33 C=l20 PT 14.84 (103) Q 43.14 F=O F 0.00 PE 0.00 BN T 9.33 0.0054 PF 0.05 113 108DQ 43.21 2.703 L 9.33 C=120 PT 14.89 (108) Q 86.35 F=O F 0.00 PE 0.00 BN T 9.33 0.0194 PF 0.18 38 113DQ 43.47 2.703 L 8.25 C=120 PT 15.07 (113) Q 129.82 F=O F 0.00 PE 0.00 BN T 8.25 0.0412 PF 0.34 28 38DQ 213.17 2.703 L 0.83 C=120 PT 15.41 ( 38) Q 342.99 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2488 PF 8.52 PT 24.29 ( 28) ------------------107 102 2.703 L 9.33 C=120 PT 14.92 (102) Q 43.27 F=O F 0.00 PE 0.00 BN T 9.33 0.0054 PF 0.05 112 107DQ 43.34 2.703 L 9.33 C=l20 PT 14.97 (107} Q 86.61 F=O F 0.00 PE 0.00 BN T 9.33 0.0195 PF 0.18 37 112DQ 43.60 2.703 L 8.25 C=l20 PT 15.15 (112) Q 130.21 F=O F 0.00 PE 0.00 BN T 8.25 0.0415 PF 0.34 27 37DQ 213.81 2.703 L 0.83 C=120 PT 15.49 ( 37) Q 344.02 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2502 PF 8.56 PT 24.41 27) ------------------106 101 2.703 L 9.33 C=120 PT 15.11 (101) Q 43.54 F=O F 0.00 PE 0.00 BN T 9.33 0.0055 PF 0.05 SUBMITrAL SERIAL NO:4144HY1 10-03-2005 PAGE 6 GREYHAWK BLDG A ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 111 106DQ 43.61 2.703 L 9.33 C=l20 PT 15.16 (106) Q 87.15 F=0 F 0.00 PE o.oo BN T 9.33 0.0197 PF 0.18 36 111DQ 43.88 2.703 L 8.25 C=l20 PT 15.34 (111) Q 131.03 F=0 F 0.00 PE 0.00 BN T 8.25 0.0419 PF 0.35 26 36DQ 215.15 2.703 L 0.83 C=120 PT 15.69 36) Q 346.19 F=T/T F 33.40 PE 0.36 NR T 34.23 0.2531 PF 8.66 PT 24.71 26) ------------------25 35 2.703 L 0.83 C=120 PT 24.57 35) Q 55.50 F=T/T F 33.40 PE 0.36 NR T 34.23 0.0086 PF 0.29 PT 25.22 25) ------------------9 10 7.758 L 160.00 C=150 PT 64.91 10) Q 803.96 F=GV F 6.04 PE 0.00 LU T 166.04 0.0047 PF 0.78 8 9DQ -466.94 7.758 L 259.00 C=150 PT 65.69 ( 9) Q 337.02 F=2GV,2EE F 39.26 PE 0.00 LU T 298.26 0.0009 PF 0.27 11 8DQ -127.27 7.758 L 145.00 C=150 PT 65.96 ( 8) Q 209.75 F=GV,T F 58.94 PE 0.00 LU T 203.94 0.0004 PF 0.08 4 11 7.758 L 120.00 C=150 PT 66.04 ( 11) Q 209.75 F=T,GV,EE F 72.53 PE 0.00 LU T 192.53 0.0004 PF 0.08 PT 66.12 ( 4) ------------------12 9 7.758 L 80.00 C=150 PT 65.69 9) Q 466.94 F=GV,T F 58.94 PE 0.00 LU T 138.94 0.0017 PF 0.24 3 12 7.758 L 215.00 C=150 PT 65.93 ( 12) Q 466.94 F=T,GV F 58.94 PE 0.00 LU T 273.94 0.0017 PF 0.47 PT 66.40 3) ------------------1 10 7.758 L 326.00 C=150 PT 64.91 ( 10) Q 1127.44 F=2EE,4GV,T F 104.24 PE 0.00 LU T 430.24 0.0088 PF 3.79 PT 68.70 1) SUBMITTAL SERIAL NO:4144HY1 10-03-2005 PAGE 7 GRBYHAWK BLDG A ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ------------------ 7 8 7.758 L 382.00 C=l50 PT 65.97 8) Q 127.27 F=T,GV F 58.94 PE 0.00 LU T 440.94 0.0002 PF 0.09 6 7 7.758 L 40.00 C=150 PT 66.06 7) Q 127.27 F=O F 0.00 PE 0.00 LU T 40.00 0.0002 PF 0.01 5 6 7.758 L 157.00 C=150 PT 66.07 6} Q 127.27 F=GV,2EE F 33.22 PB 0.00 LU T 190.22 0.0002 PF 0.04 4 5 7.758 L 320.00 C=lSO PT 66.11 5) Q 127.27 F=GV F 6.04 PE 0.00 LU T 326.04 0.0002 PF 0.07 3 4DQ 209.75 7.758 L 266.00 C=150 PT 66.18 4) Q 337.02 F=2GV,EE F 25.67 PB 0.00 LU T 291.67 0.0009 PF 0.26 2 3DQ 466.94 7.758 L 75.00 C=l50 PT 66.44 3) Q 803.96 F=GV F 6.04 PB 0.00 LU T 81.04 0.0047 PF 0.38 1 2 7.758 L 314.00 C=150 PT 66.82 2) Q 803.96 F=2GV,T,2EE F 92.16 PE 0.00 LU T 406.16 0.0047 PF 1.91 PT 68.73 ( 1) ------------------28 29 6.357 L 10.00 C=120 PT 24.24 29) Q 342.71 F=O F 0.00 PE 0.00 FMl T 10.00 0.0039 PF 0.04 27 28DQ 342.99 6.357 L 10.00 C=120 PT 24.28 ( 28) Q 685.70 F=O F 0.00 PE 0.00 FMl T 10.00 0.0139 PF 0.14 26 27DQ 344.02 6.357 L 10.00 C=120 PT 24.42 { 27) Q 1029.72 F=O F 0.00 PE 0.00 FMl T 10.00 0.0295 PF 0.30 25 26DQ 346.19 6.357 L 10.00 C=120 PT 24.72 ( 26) Q 1375.90 F=O F 0.00 PE 0.00 FMl T 10.00 0.0505 PF 0.51 24 25DQ 55.50 6.357 L 4.00 C=120 PT 25.23 { 25) Q 1431.41 F=T F 31.43 PE 0.00 FMl T 35.43 0.0543 PF 1.92 SOBMI'ITAL SERIAL NO:4144HY1 10-03-2005 PAGE 8 GREYHAWK BLDG A ROOF .45/3000 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 23 24 6.357 L 30.75 C=120 PT 27.15 ( 24) Q 1431.41 F=E F 12.57 PE 0.00 FM T 43.32 0.0543 PF 2.35 22 23 6.357 L 20.50 C=l20 PT 29.50 ( 23) Q 1431.41 F=2E F 25.14 PE 8.02 FR T 45.64 0.0543 PF 2.48 21 22DQ 100.00 6.340 L 7.00 C=140 PT 40.00 ( 22) Q 1531.41 F=2E F 46.22 PE 0.00 UN T 53.22 0.0469 PF 2.50 20 21 5.914 L 24.00 C=150 PT 42.50 ( 21) Q 1531.41 F=2EE,GV F 26.18 PE 2.06 UN T 50.18 0.0579 PF 2.91 COMMENT: ELEVATION DIFFERENCE FROM FLOW TEST TAKEN HERE 16 20 5.914 L 23.00 C=150 PT 47.47 ( 20) Q 1531.41 F=4E,DCA F 86.28 PE 0.00 UN T 109.28 0.0579 PF 6.33 6" DOUBLE CHECK DETECTOR ASSEMBLY 7.28 10 16DQ 400.00 7.758 L 76.00 C=150 PT 61.08 ( 16) Q 1931.41 F=T,GV,B F 86.12 PE 0.00 UN T 162.12 0.0237 PF 3.84 PT 57.64 ( 10) ---------------·--0 1 7.758 L 1.00 C=l50 PT 68.68 ( 1) Q 1931.41 F=0 F 0.00 PE 0.00 UN T 1.00 0.0237 PF 0.02 PT 68.70 { 0) MATERIAL DATA SUBMITTAL GREYHAWK BUSINESS PARK BLDG. A, 3210 GREYHAWK CT. CARLSBAD, CA. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DRIVE, STE. F OCEANSIDE, CA 92056 760-806-9997 • 760-806-4813 F,AX tqca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 C 1: Tel: (414) 570-50 ) 558-5236 Fax: (414) 570-501 ) BTT-1295 Series TY-FRB -2.8, 4.2, 5.6, and 8.0 K-facfo Upright, Pendent, and Recessed Pendent Spri klers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, \,Jpright and Pendent Sprinklers described in thi,s data sheet are quick response -standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19, 1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 Inch (6,4 mm) of recessed adjust- ment or up to 1/2 Inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING· that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or Its compo- nents and cause the sprinkler to fail to operate In a fire situation or cause It to operate prematurely. Page 1 of8 mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi~ ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the • Serles TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained In compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, In addition to the standards of any other authorities hav- ing jurisdiction. Fa/lure to do so may Impair the performance of theN de- vices. The owner Is responsible for maintain- Ing their fire protection system and de- vices In proper operating condition. The Installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 • TY1231- TY2131- TY2231 • TY3131 • Upright 2.8K, 112•NPT Pendent 2.8K, 112·NPT Upright 4.2K, 112"NPT Pendent 4.2K, 1/2"NPT Upright 5.6K, 1/2"NPT JULY,2004 ....... , , f • ,r I I - TY3231 • TY4131 • TY4231- Penden 5.6K, 1/2"NPT Upright I.OK, 314"NPT Penden a.OK, 314"NPT Technic Data Approval• UL and C-UL Listed. FM, LPCB, and NYC pproved. (Refer to Table A for mplete approval Information Including corrosion resis- tant status.) Maximum Working re91ure 175 psi (12, 1 bar) Discharge Coefflcle t K = 2.8 GPM/psi112 ( 0,3 LPM/bar112) K = 4.2 GPM/psi112 ( 0,5 LPM/bar112) K = 5.6 GPM/psi112 ( ,6 LPM/bar11'2) K,., 8.0 GPM/psi112 (1 5,2 LPM/bar112) TFP171 Page2 of 8 ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2mm) 1/2" ** NPT 7/16" (11,1 mm) NOMINAL MAKE-IN i STYLE 10 or 20 RECESSED ESCUTCHEON ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 1-9/16" (39,7 mm) WRENCH FLATS 2-3/16" (55,6mm) ' SSP DEFLECTOR * PENDENT 1 • Frame 2 • Bulton 3 • Sealing Assembly 2·7/8" (73,0 mm) DIA. --l RECESSED PENDENT 4•Bulb 5 • Compression Ser- 6 -Deflector 7 -Bushing RGURE1 1/2" NPT** UPRIGHT • Temperature rating Is Indicated on defle orifice seat on frame. **Pipe thread connections per ISO 7/1 ca special request QUICK RESPONSE SERIES TY-FRB UPRIGln' (TY1131J AND PENDENT (TY1231} SPRINKi ERS 2.B K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 1 2-3116" (55,6mm) 1-1/2" (38,1 mm) 112· ** NPT 7/16" (11,1 mm) NOMINAL MAKE-IN I STYLE 10 or 20 RECESSED ESCUTCHEON SSP DEFLECTOR* PENDENT L 2-718" (73,0 mm) DIA, RECESSED PENDENT 1 -Frame 2 • Button 3 • Sealing Assembly 4•Bulb S • Compression Screw 6-Deflector FIGURE2 ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3116" (55,6 mm) 112" NPT** UPRIGHT t ' • Temperature rating is Indicated on defle orifice seat on frame. ** Pipe thread connections per ISO 7/1 ca special request. QUICK RESPONSE SERIES TY-FRB UPRIGln' {TY2131} AND PENDENT (TY2231J SPRINKI 4.2 K-FACTOR, 1/2 INCH NPT Flnlahe, Bulb .............. Glass Operatio TFP171 6* 5 2 3 Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Phyalcal Characteristics Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . Compression Screw . . . . . Bronze Deflector . . . . . . . Copper/Bronze Bushing (K=2.8) . . . . . . . Bronze The glass Bulb con ns a fluid which expands when exp d to heat. When the rated temperatur is reached, the fluid expands sufficie tly to shatter the glass Bulb, allowing the sprinkler to activate and water to ow. . . . . . Beryllium Nickel w/Teflont TFP171 ESCUTCHEON PLATE SEATING SURFACE 2·3/16" (55,6mm) 1-112· (38,1 mm) 112· ** NPT 7/16" (11,1 mm) NOMINAL MAKE-IN i STYLE 10 or 20 RECESSED ESCUTCHEON WRENCH FLATS SSP DEFLECTOR* PENDENT 2-7/8' (73,0 mm) DIA. j RECESSED PENDENT ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3/16" (55,6mm) ! 1/2" NPT** UPRIGHT Page 3ot8 5 2 3 1-Frame 2 • Button 3 • Sealing Assembly 4 • Bulb 5 • Compression Screw 6 • Deflector • Temperature rating Is Indicated on defle or or adjacent to orifice seat on frame. .. Pipe thread connections per ISO 7/1 can be proYidad on special request. FIGURE3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT {TY3231) SPRIN 5.6 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-6118" (58,7 mm) 1/2' (12,7 mm) 314• ** NOMINAL NPT MAKE-IN _l SSP DEFLECTOR* PENDENT STYLE 30 or 40 RECESSED ESCUTCHEON ssu* DEFLECTOR 1/Z' (12,7mm) NOMINAL MAKE-IN 2·1/4" (57,2mm) ,.,..NPr~ UPRIGHT 5 2 3 1 • Freme 2· Button 3· Sealing Assembly 4-Bulb 5 • Compression Screw 6-Deflector • Temperature rating Is Indicated on defle or or adjacent to orifice seat on frame. **Pipe thread comectlons per ISO 7/1 can special request. FIGURE4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINK, ERS Design Criteria The Serles TY•FRB Pendent and Up- right Sprinklers are Intended for fire protection systems designed In ac- cordance with the standard Installation rules recognized by the applicable Listing or Approval agency (e.g., UL 8.0 K-FACTOR, 3/4 INCH NPT Usting is based on the requirements of NFPA 13, and FM Approval Is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30. or 40 Recessed Escutch• eon, as applicable, is to be used for recessed pendent Installations. The Series TY-FRB S Installed In accorda ing instructions: NO Do not Install any bul type sprinkler if th& bulb Is cracked o there Is a loss of I/quid from thB bulb. 1th thB sprinkler Page4of8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL I CHROME I, WHITE ... LIQUID BRASS PLATED POLYESTER 135"F/57"C Orange PENDENT 155"F/68"C Red (TY1231) 1, 2, 3, 5 and 175"Fmf'C Yellow UPRIGHT 200°F/93°C Green 2.8 (TY1131) 286"F/141 •c Blue Mi!" NPT 135°F/57"C Orange RECESSED 155°F/68"C Red PENDENT (TY1231)* 175°Fmf'C Yellow Figures 200"F/93°C Green 1, 2, 5 135"F/57"C Orange RECESSED 155"F/68°C Red PENDENT (TY1231) .. 175"Fn9•C Yellow Figure& 200°F/93°C Green 135"F/57"C Orange PENDENT 155"F/68"C Red {TY2231) and 175°F/79"C Yellow UPRIGHT 200°F/93°C Green 42 (TY2131) 286"F/141"C Blue 1.12" 1, 2 NPT 135"F/57"C Orange RECESSED 155"F/68"C Red PENDENT (TY2231)" 175°Fl79"C Yellow Flgure7 200"F/93"C Green 135"F/57"C Orange RECESSED 155°F/68°C Red PENDENT (TY2231) .. 175"Fn9°C Yellow Figure& 200°F/93°C Green ~ by Underwriters Laboralorl$s, Inc. (UL) as Quiek Response Sprinklers. 2. Ustad by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approwd by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. • 5. Approwd by the City of New York under MEA 354-01-E. 7. Where ~er Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers ara UL and C-UL Listed as Corrosion Reai&tant Sprinklers. • Installed with Style 10 (1/2" NPT) or Style 40 (314" NPT) 314" Total Adjustment Rece&&ed Eecutc:heon, ae applicable. *" Installed with Style 20 (1/2" NPT) or Style 30 (S/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. -• Frame and Deflector only. Listings and approvals apply to color (Special Order). NIA: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS held horizontally, a small air bubble should be present. The diameter of the sir bubble is approximately 1/16 Inch (1,6 mm) for the 135°F/57°C to 3132 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtai11Bd with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi• mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 314 TFP171 inch NPT sprinlcler jo, t should be ob- tained with a torque f 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40, 7 Nm) of ton ue Is to be uS8d to Install sprinklers w 314 NPT con- nections. Higher /eves of torque may distort the sprinkler nlet and cause leakage or impairmen of the sprinkler. Do not attempt to &-Up for Insuffi- cient adjustment in he escutcheon plate by under-or 0111 ,-tightening the sprinkler. Readjust th position of the sprinkler fitting to suit The Serles TY--FRB dent and U~ right Sprlnklen1 m be installed in accordance with the t llowing instruc- tions. Step 1. Pendent sprl klers are to be Installed in the pend nt position, and upright sprinklers are be Installed In the upright position. Step 2, With pipe th ad sealant ap- plied to the pipe th s, hand tighten the sprinkler Into the rinkler fitting. Step 3. Tighten the prinkler into the sprinkler fitting using nlr. the W-Type 6 Sprinkler Wrench . Figure 13). With reference to Fig res 1, 2, 3, and 4, the W-lype 6 Sprln er Wrench Is to be applied to the s rlnkler wrench flats. The Serles TY-FRB ce888d Pen- dent Sprinkler, m t be installed In accordance with the !lowing instruc- tions. Step A. After lnstatll g the Style 10. 20, 30, or 40 Mountln Plate, as appll- cable, over the sprln er threads and with pipe thread seal t applied to the pipe threads, hand ti hten the sprin- kler Into the sprinkler ttlng. Step B. Tighten the prlnkler Into the sprinkler fitting using nly the W-Type 7 Recessed Sprlnkl r Wrench (Ref. Figure 14 ). With refer nee to Figure 1, 2, 3. and 4, the w-7 Recessed Sprinkler Wrench Is o be applied to the sprinkler wrench ats. Step C. After the eel ng has been In- stalled or the finish t haa been ap- plied, sllde on the e 1 o, 20, 30, or 40 Closure over the Serles TY-FRB Sprinkler and push Closure over the Mounting Plate until Its flange comes In contact wit the celling. . TFP171 Page5of8 SPRINKLER flNISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME WHITE*" LEAD LIQUID BRASS PLATED POLYESTER COATED 136°F/6"1°C Orange PENDENT 155°F/68°C Rad {TY3231) 1, 2, 3, 4, 6, 6, 7 1,2,3, 5 and 175°Fn9°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3131) 286"F/141 "C Blue 112· NPT 135°F/57"C Orange RECESSED 155°F/68°C Red PENDENT 1, 2,4,5 NIA {1Y3231)* 175°F/79"C Yellow Figure& 200°F/93°C Green 135°F/51°c Orange RECESSED 155°F/68°C Rad PENDENT 1, 2, 3, 4, 5 1,2,4,5 NIA (TV3231)" 115°Fne·c Yellow Flgure10 200°F/93"C Green 135"F/57°C Orange PENDENT 155°F/68°C Rad {1Y4231) 1,2, 5 and 175°F/79°C Yellow 1,2,3,4,5,6, 7 UPRIGHT 200°F/93°C Green 8.0 {1Y4131) 286"F/141°C Blue 314• NPT 135°F/57"C Green RECESSED 155"F/68°C Orange PENDENT 1, 2, 4, 5 NIA {1Y423W 175°Fn9°C Red Figure 11 200"F/93"C Yellow 135°F/57"C Orange RECESSED 155°F/68"C Red PENDENT 1, 2, 3,4, 5 NIA {1Y4231)*" 175°F/79"C YeUow Flgure 12 200°F/93"C Green NOTES: 1. Uatad by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Ustad by Underwriters Laboratories, Inc. for use In Canada (C•UL) u Quick Reeponaa Sprinkle,.._ 3. Approved by Faclory Mutual Research Corporation (FM) as Quick Raeponae Sprlnklera. 4. Approved by the Losa Prevention Certifloatlon Board (LPCB Ref, No. 007k/04) as Quick Response Sprinklers: howew ~. the LPCB does not rate the thermal aanslttvlty of l'8C8S88d aprlnlclera. 5. ApprOll8d by the City of New 'tbrk I.Nldar MEA 354-01-E. 6. VdS Approved (For detalla contact lyCo Fll'9 & Building Products, Enachade, Netherlands, Tai. 31-53-428-4444/Fax 31 -53-428-33n). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/08) aa Quick Response Sprlnklera. a. Where Polyeatar Coated and Lead Coated Sprinklers are noted to be UL and C·UL Listed, the aprlnklem are UL and l}-IJL U8ted as Col'l'OSlon Reelatant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Corroalon Reslatant Sprlnkleta. r-r---MB • lnatalled with Style 10 (1/2" NPT) or Style 40 (3'4" NPT) 3/4" Total Adjustment Recessed Eacutcheon, as appDcable. " Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 112• Total Adjustment Recessed Escutcheon, u applicable . ... Frame and Defteclor only. Uatlnga and approval• apply to color ($peclal Order). NIA: Not Available TABLES LABORATORY LlsnNGS AND APPROVALS 5.6 AND B.O K-FACTOR SPRINKLERS Page &of 8 518±1/4' (15,W,4mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8" DIA. ;l (73,0mm) 2-1/4' DIA. -:1 (57.2mm> TI 3/4' 19,1 mm 1/4' (6,4 mm) SERIES TY-FRB FIGURES 1-5/16" 33,3 mm 13/16' (20,6 mm) 112:t:1/8' (12,7~.2 mm) FACE OF SPRINKLER FITTING \ 2·7/8' DIA. (73,0mm) ;l 2-1/4' DIA. (57,2mm) 71 FIGURE6 TFP171 /2' 12,7mm) 1/4' (6,4 mm) SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED P, 'NDENT WITH TWo-P/ECE 3/4 INCH TOTAL ADJUST&fENT STYLE 10 RECESSED ESCUTCHEON WITH TWO-PIECE 112 INCH TOTAL IJSTIIENT STYLE 20 RECESSED ESCU71 EON 2.8 K-FACTOR, 112 INCH NPT 2.8 K-FACTOR, 1/2 INCH 'PT ~114' (15,W,4 mrn) FACE OF SPRINKLER FITTING CLOSURE 2-7/8' DIA. ;l (73,0mm) 2-1/4' DIA. -:1 1s1.2mm> TI 314' 19,1 mm 1/4" (6,4 mrn) SERIES TY-FRB FIGURE7 1-1/4' (31,6 mm 3/4' (19,1 mm) 112:t:1/8" (12,7:loS,2 mm) FACE OF SPRINKLER FITTING \ CLOSURE 2-7/8' DIA. ;l (73,0mm) 2-1/4' DIA. -:1 (57,2mm) TI r.t' 12,7mm 114" (6.4 mm) FIGURES 1· /4' 1,8mm • (25,4mm) SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED P, 'NDENT Wl1H TWo-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON WITH TWO-PIECE 1/2 INCH TOTAL USTIIENT STYLE 20 RECESSED ESCU HEON 4.2 K-FACTOR, 112 INCH NPT 4.2 K-FACTOR, 1/2 INCH PT Care and Maintenance The Serles TY-FRB Sprinklers must be maintained and serviced In accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may rJe/ay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaklng or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fled sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced If they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, triking, wrench twist/slippage, or the ike, must be re- placed. Also, replace ny sprinkler that has a cracked bt.!lb r that has lost liquld from Its bulb. Ref. Installation Section). Frequent visual ins ions are rec- ommended to be lnltl lly performed for corrosion resistant ated sprinklers, after the Installation has been com- pleted, to verify the I grlty of the cor- rosion resistant coa Ing. Thereafter, annual inspections per NFPA 25 should suffice; howev r, instead of in- specting from the floo level, a random sampling of close-u visual Inspec- tions should be mad , so as to better determine the exact sprinkler condi- TFP171 518:1:1/4' (15,9:t:6,4 mm) FACE OF SPRINKLER FITTING CLOSURE 2-7/8' DIA. ;l (73,0mm) 2•1/4' DIA. -, cs1.2mm1 r l FIGURES 314' 19,1 mm 1/4' (6,4 mm) MOUNTING PLATE 1-1/4' 31,8 mm 314' (19,1 mm) SERIES TY-FRB RECESSED PENDENT 1/2:tl/B" (12,7:1:3.2 mm) FACE OF SPRINKLER FITTING \ CLOSURE 2•7/8'01A. ;l (73,0mm) 2·1/4" DIA. --71 <s1.2mm> r I FIGURE10 SERIES TY-FRB RECESSED Pa .. 7ot8 /2' (12,7mm 1/4" (6.4 mm) MOUNTING PLATE 1· /4' 1,8mm '(25,4mm) WITH TWo-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON WITH TWO-PIECE 1/2 INCH TOTAL A USTMENT STYLE 20 RECESSED ESCUTI HEON 5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 112 INCH H T 5/St1/4" (15,M,4mm) FACE OF SPRINKLER ATTING CLOSURE ~~!·~::)=;l 314' 19,1mm 2-1/4" DIA. --j 1/4" (6,4 mm) cs1.2 mm> .J I SERIES TY-FRB FIGURE11 1·5.'18' 33,3 mm 13118' (20,8 mm) 112:t:1/8' (12,7~.2 mm) FACE OF SPRINKLER FITTING CLOSURE 2-7/8' DIA. (73,0mm) 2-1/4" DIA. (57,2mm) SERIES TY-FRB RGURE12 /2' (12,7 mm) 1/4' (6,4 mm) MOUNTING Pl.ATE SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PEi 'DENT WITH TWo-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON WITH TWo-PIECE 112 INCH TOTAL USTMENT STYLE 30 RECESSED ESC 'EON 8.0 K-FACTOR, 314 INCH NPT 8.0 K-FACTOR, 314 INCH H T tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the In- spection, testing, and maintenance of their fire protection system and de- vices In compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative. to any questions. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS (END "A" USED FOR 112' NPT MODELS) WRENCH RECESS (END 'B" USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH local requirements and/or national cbdes. p INTO ENGA WITHS WAENC Page 8 of8 TFP171 P/N 57-XXX-X-XXX I I I !TEMF ERATURE MODEUSIN RmNG SPRINKLER 330 2.8K UPRIGHT (1/2"NPT) TY1131 135 13l: °F/57°C 331 2.8K PENDENT (1/2"NPT) TY1231 1 NATURAL BRASS 155 15!: °F/68"C 340 4.2K UPRIGHT (1/2"NPT) TY2131 4 WHITE POLYESTER 175 17!: "F/79"C 341 4.2K PENDENT (1/2"NPT) 370 5.6K UPRIGHT (1/2"NPT) 371 5.6K PENDENT (1/2"NPT) 390 8.0K UPRIGHT (3/4"NPT) 391 B.OK PENDENT (3/4"NPT) TY2231 3 WHITE (RAL9010)* TY3131 TY3231 TY4131 TY4231 9 CHROME PLATED 7 LEAD COATED TABL.EC PARTNUMBERSEL.ECnON 200 20( °F/93°C 286 286' F/141"C • Eastem Hemisphere ;alesonly. SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects In material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten {1 0) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manUfactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, Improper Installation, corro- sion, or which have not been installed, maintained, modified or rePi&lred In ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or repleed, at Tyco Fire Products' sole optiOh. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for It, any other obligation in connection with the sale of products or parts of products. 'Tyco Fire Producfs shall not be responsible for sprinkler system design errors or inaccurate or Incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHAU TYCO FIRE PRODUCTS BE LIABLE, lN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT UMITl:O TO LABOR CHARGES, RE;· GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' U- ABIUIY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE EQBEOQING WARRANTY IS MADE IN LIEU OF ANY AND ALL QTHER WARRANT/ESEXPRE$$ QB tMPLIEQ. INCLUDING WARRANTIES QF MERCHANTASILITY AND FIT- NESS FOR A PARTICULAR pus- l!DS£ Ordering Procedure IIDnt-.,0 &Deal distributor for avall- ablfllv.lndlcate Iha fiii'pn)duct name. ~afac to Iha Price Ult lot complllla Uallng of Pait Numbers. Sprinkler AuembUes with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Serles TY•FR8 (speelfy Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Tabla C). ReceNed EacutclNM •n: Specify: Style (specif•) Recessed Es· cutcheon with (spei ify finish), PIN (specify). 1/r (1Smm) Style 10 Clll'ome Plated . . . . . . . . . . . PIN 58-701-9-010 White Coated . . . . . . . . . . . . PIN 58-701-4-010 White RAL9010" ... , . . . . . . PIN 58-701¼010 Brass Plated............ . PIN 58-701-2.010 112• {15 mm) Style 20 Chtoma Plated ............ PIN 58-705-9.()10 Whltll Coe•d . . . . . . . . . . . . . PIN 56-705-4-010 White RAL90to• ...... , .. ,. PIN 58•705-3.()10 Brase Plated,, ........ , .. , PIN 58•705-2-010 314• (20mm) Style 30 ChlOma Plated . . . . . . . . . . . P/N 58-705-9-011 White Coetad· .. .. .. . . . . . . . PIN 56-705+011 White FIAl.9010-........... PIN 58-705-3-()11 Brae Plated ........... , . PIN 56-705'-2.011 314• (20 mm) Style 40 Chroma Plllhld . . . . . . . . . . . PIN 58-700-&-010 White Coated . . . . . . . . . . . . PIN 58-700-4-010 White RAUI010•. , . . . . . . . . PIN 58-700-3-010 B-Plated . .. .. . .. . . . . . PIN 58-700-2-010 • Eaatam H ml■p/a'a aaJn anly. Sprinkler Wrench: Specify: W-Type 6 811rinkler Wrench, PIN 56-000-6-387. Specify: W-Type 7 S1 ,rinkler Wrench, PIN 56-850-4·CX>1. TYCO FIRE PRODUCTS, 451 North Camon Avenue, Lansdale, Pennsylvania 19446 -tqca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 fl Customer Service/Sales: Tel: (414) 570-5000/ (800) 558-5236 Fax: (414) 570-5010/ (800) 877-1295 Series EL0-231 B -11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description The 11.2 K-factor, Serles ELO-231 B, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin- klers of the frangible bulb type. They are "standard response -spray sprin- klers" that produce a hemispherical water distribution pattern below the de- flector. The 11.2 K-factor, ELO-2318 Sprin- klers were subjected to full scale, high- piled storage, fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor stand- ard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, ELO-231 8 Sprinklers - making their use highly advantageous in high density applications, such as the protection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy com- ponents used in Series ELO-231 B sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lead, and polyester coated sprin- klers have passed the standard corro- sion tests of the applicable approval agencies, the testing is not repre- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNINGn that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 sentatlve of all possible corrosive at- mospheres. Consequently, it is recom- mended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The ef- fects of ambient temperature, concen- tration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive na- ture of the chemical to which the sprin- klers will be exposed. An upright intermediate level version of the Series ELO-231 B Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-231 B Up- right Sprinkler wi1h the WSG-2 Guard & Shield, and a pendent intermediate level version of the Series ELO-231 B • Sprinklers can be obtained by utiliz- ing the Series ELO-231 B Pendent Sprinkler with the WS-2 Shield. If there is a possibility of the pendent interme- diate level version being exposed to mechanical damage, a G-2 Guard can be added. WARNINGS The 11.2 K-factor, Series EL0-231 B Upright and Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de-- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Installation of Series EL0-231 B Pen- dent Sprinklers in recessed escutch- eons will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. JANUARY, 2005 TFP342 Page 2 of 6 TFP342 SPRINKLER FINISH TYPE TEMPERATURE BULB NATURAL I CHROME LEAD I WAX I WAX LIQUID BRASS PLATED COATED COATED OVER LEAD UPRIGHT 155°F/68°C Red 3 (TY5151 200°F/93°c Green & 1, 2, 3, 4 TY5851) 286°F/141°C Blue 3 I 3(a) 1ss°F/6s0c Red 3 PENDENT 200°F/93°C Green (TY5251 1, 2, 3, 4 2ss°F/141 ·c Blue 3 I 3(8) NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL Listed). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL Listed). 3. Approved by Factory Mutual Research Corporation (FM Approved). 4. Approved by the City of New York under MEA 291-04-E. (a). FM Approved for a maximum ceiling temperature of 150°F/66°C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K-FACTOR SERIES EL0-231B UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Identification Numbers TY5151 -Upright 11.2K, 3/4"NPT TY5251 -Pendent 11.2K, 3/4"NPT TY5851 -Upright 11.2K, 1/2-NPT TY5151 is a redesignation for C5151. TY5251 is a redesignation for C5251, G1871, and S2531. TY5851 is a redesignation for C5851. Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12, 1 bar) Discharge Coefficient K = 11.2 GPM/psi112 (161,4 LPM/bar112) Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame . . . . . . . . . . . . . Bronze Cap .............. Bronze Sealing Assembly . . . . . . . . . . . . . . . . . Beryllium Nickel w/Teflont Bulb (5 mm dia.) ....... Glass Compression Screw . . . . . Bronze Deflector . . . . . . . . . . . . Bronze t Registered trademark of DuPont. Design Criteria UL and C-UL Listing Requirements The 11.2 K-factor, Model ELO-231 B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with NFPA 13 standard sprinkler posi- tion and area/density flow calculation requirements for light, ordinary, or ex- tra hazard occupancies with a mini- mum residual (flowing) pressure of 7 psi {0,5 bar) in wet or dry pipe sprinkler systems, or they are to be Installed in accordance with NFPA 13 standard sprinkler position and area/density flow calculation requirements for high piled storage occupancies (solid piled, palletized, rack storage, bin box, and shelf storage including but not limited to Class I-IV and Group A plastics) with a minimum residual (flowing) pressure of 10 psi (0,7 bar) for wet or dry pipe systems. The following example is typical of the type of arrangement permitted by NFPA 13. For all combinations of lesser and greater building heights, lesser and greater storage heights, storage arrangements, commodity classifications, and lesser or greater required design densities, refer to NFPA 13 for specifics. Example: NFPA 13 provides celling only protection (i.e., no in-rack sprin- klers) criteria using open frame (i.e. no solid shelves) single, double, multlple- row, or portable rack storage (without TFP342 * Temperature rating Is indicated on deflector. ** Pipe thread connecdons per ISO 7/1 can be provided on special request 2-13/16" (71,4 mm) TYP. 7/16" (11,1 mm) NOMINAL MAKE-IN UPRIGHT TY5851 12•** PT l112• (12,7 mm) NOMINAL MAKE-IN UPRIGHT TY5151 1/2' (12,7 mm) ~MINALMAKE-IN THREAD RELIEF RGURE1 PENDENT TY5251 11.2 K-FACTOR SERIES EL0-231B 314••· NPT CROSS SECTION Page 3 of 6 Components: 1 -Frame 2 -Seal Assembly 3 -Cap 4 -Bulb 5 -Compression Screw 6 -Deflector * UPRIGHT-3/4" NPT (TY5151), UPRIGHT-112" NPT {TY5851), AND PENDENT-3/4" NPT {TY5251) SPRINKLERS the need for in-rack sprinkler protec- tion) of cartoned or uncartoned unex- panded Group A or B plastics, or, car- toned expanded Group A or B plastics, with: • a storage height of up to 20 feet (6, 1 m); • a maximum ceiling height of 27 feet (8,2 m); • a minimum deflector to top of stor- age clearance of 18 inches (457 mm); • a minimum design density of 0.60 gpmlft2 (24,4 mm/min); • a minimum residual (flowing) pres- sure of 10 psi (0,7 bar); • a minimum design area of 2000 ft2 (186 m2) for wet systems or 2600 ft2 (242 11¥) for dry pipe systems FM Approval Requirements The 11.2 K-factor, Model EL0-231 B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with the applicable "control mode den- sity/area" guidelines provided by Fac- tory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Installation The Series EL0-231 B Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C to 3/32 inch (2,4 mm) for the 286"F/141°C temperature ratings. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40, 7 Nm) of torque is to be used to install sprinklers with 3/4 NPT connections. A leak tight 1/2 inch NPT sprinkler joint should be ob- tained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for lnsuffi- "FITTING SIDE" TOWARDS SPRINKLER FITTING FIGURE2 W-TYPE 3 SPRINKLER WRENCH cient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Serles EL0-231 B Upright and Pendent Sprinklers must be installed in accordance with the following in- structions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 3 Sprinkler Wrench (Ref. Figure 2), except that an 8 or 1 o inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Page 4 of 6 Figure 1, the W-Type 3 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After Installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching Is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which Is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of Initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. Care and Maintenance Series ELO-23 t B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system control valve for maintenance work on the fire protection system that it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personflBI who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi• lied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual Inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. TFP342 It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national code. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by·Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL,. INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE· GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FQREGQING WARRANTY IS MADE IN LIEU QE ANY AND AU, QTHER WARRANTIES EXPRESS DR IMPLIED. INCLUDING WARRANTIES Of MERCHANTABILITY AND FIT-NESS FOR A PARTICULAR PUB- I!.OSL TFP342 Ordering Procedure A Part Number (P/N) is not specified when ordering sprinklers with thread connections per ISO 7/1. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connection: Specify: (specify SIN), 11.2 K-factor, (specify temperature rating), Series EL0-231 B Standard Response (spec- ify Pendent or Upright) Sprinkler with {specify finish), PIN (specify from Ta- ble B). Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries EL0-231B Sprinklers, PIN (spec- ify). Red for 155°F ............. P/N 56·065·1-155 Blue for 2oo•F and 286"F ................. P/N 56-065-1·286 NOTES Each wax stick is suitable for retouch· ing up to twenty-five sprinklers. The wax used tor 286°F sprinklers Is the same as tor 200°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 1so°FJ. 510 512 501 Page 5 of 6 P/N 50-XXX-X-XXX I SPRINKLER TEMPERATURE TYPE UPRIGHT 3/4" NPT (TY5151) PENDENT 3/4" NPT (TY5251) UPRIGHT 1/2" NPT (TY5851) 1 9 6 7 8 NATURAL BRASS CHROME PLATED WAX COATED LEAD COATED WAX OVER LEAD TABLES 155 200 286 PRODUCT SYMBOL NUMBER SELECTION 11.2 K-FACTOR SERIES EL0-231B RATING 155°F/68°c 200°F/93°C 286°F/141 °C STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS Page 6 of 6 TFP342 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Gem Customer ServicelSalaa: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010 / (800) 877-1295 Series TY-B -2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-8, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described In this data sheet are standard response -standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-8 Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (112 inch NPT}orStyle40(3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing Is IIIPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and In- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate In a fire situation or cause It to operate prematurely. Page 1 of8 not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Serles TY-B Pendent Sprinkler can be obtained by utilizing the Serles TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-8 Sprinklers described herein must be installed and main- tained in compliance with this docu- ment as well as with the applicable standards of the National Fire Protec- tion Association, In addition to the standards of any other authorities hav- ing jurisdiction. Fa/lun, to do so may Impair the performance of theae de- lflcu. The owner Is rt1Sponslble for maintain- Ing their fire protection system and de- vices In proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1151 • TY1251- TY3151- TY3251- TY4151 • TY4251- TY4851- TY4951 • Upright 2.8K, 112•NPT Pendant 2.8K, 1/2"NPT Upright 5.6K, 1/2"NPT Pendent 5.8K, 1/2"NPT Upright 8.0K, 3/4"NPT Pendent a.OK, 3/4"NPT Upright 8.0K, 1/2"NPT Pendant 8.0K, 1/2"NPT JULY, 2004 ( I .. ... r • , l , - •• .. ..... TFP151 Page2of8 ESCUTCHEON PLATE SEATING SURFACE 1 2-1/4" (57,2 mm) 1-9/16" (39,7mm) 1/2" ** NPT 7/16" (11, 1 mm) NOMINAL MAKE-IN ' ssp• DEFLECTOR ssu* DEFLECTOR 6 lf=:;lf-----5 ---4 ----2 ,is:.,:;o--3 TFP151 PENDENT UPRIGHT CROSS SECTION 1 • Frame 2 • Button 3 -Sealing Assembly 4 • Bulb 5 -Compression Screw 6 -Oefleclor 7 • BuShlng F/GURE1 * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16' (55,6mm) 1-112· (38,1 mm) 1/2" ** NPT 7/16" (11,1 mm) NOMINAL MAKE-IN i STYLE 10 RECESSED ESCUTCHEON WRENCH FLATS SSP DEFLECTOR* PENDENT 2-718' (73,0 mm) DIA. ---l RECESSED PENDENT 1 -Frame 2 • Button 3 -Sealing Assembly 4 • Bulb 5 • Compression Screw 6 • Deflector FIGURE2 ssu* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3,116" (55,6mm) 1/2' NPTH UPRIGHT ' CROSS SECTION * Temperature rating Is Indicated on deflector or adjacent to orifice seat on frame. ... Pipe thread connections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT TFP151 Page 3of 8 ESCUTCHEON PLATE SEATING SURFACE 1/2" (12,7 mm) NOMINAL MAKE-IN STYLE40 RECESSED ESCUTCHEON ssu* DEFLECTOR 2-5/16" (58,7mm) _l 7 WRENCH Fl.ATS 112" (12,7 nun) NOMINAL MAKE-IN 2-1/4" (57,2mm) a* 5 2 3 SSP DEFLECTOR* PENDENT 2-7/8" (73,0 mm) DIA. --l RECESSED PENDENT -NPT~ UPRIGHT CROSS SECTION 1 -Frame 2 -Button 1 -Frame 2 -Button 3-Seallng Assembly 4-Bulb 5 -Compression Screw 6 -Deflector 7 -Ejection Spring FIGURE3 * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151} AND PENDENT (TY4251} SPRINKLERS B.O K-FACTOR, 314 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2mm) 1-9/16" (39,7mm) 112· ** NPT 7/16" (11, 1 mm) NOMINAL MAKE-IN t SSP* DEFLECTOR ssu* DEFLECTOR *6 5 2 3 PENDENT UPRIGHT CROSS SECTION 3 -Sealing Assembly 4-Bulb 5 -Compression Screw 6 • Deflector FIGURE4 * Temperature rating Is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. • STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951} SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Page4of8 TFP151 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL 1 CHROME WHITE""* LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135°F/57°C Orange PENDENT 155°F/68"C Red 2.8 (TY12S1) 1, 2, 3 NIA 1/2" and 175°F/79°C Yellow NPT UPRIGHT 200°F/93°C Green (TV1151) 286°F/141°C Blue 360"F/182°C Mauve 1, 2 135°F/57"C Orange PENDENT 155°F/68°C Red (TY3251) 1,2,3,4,5,6, 7 1,2, 3, 5 1,2, 3, 5 1, 2, 3, 5 and 175°Fll9°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3151) 286°F/141°C Blue 1** .2**, 3**, 5** 1**, 2**, 3**, 5** 1/2" NPT 360°F/182°C Mauve 135°F/57"C Orange RECESSED 155°F/68°C Red PENDENT 1,2, 3, 4, 5 (TY3251)* 175"Fll9°C Yellow Flgure4 200"F/93°C Green 135°F/57"C Orange PENDENT 155°F/68°C Red (TY4251) and 175°F/79°C Yellow 1, 2, 3, 4, 5, 6, 7 8.0 UPRIGHT 200°F/93°C Green 314• (TY4151) 286°F/141°C Blue NPT 360°F/182°C Mauve 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 (TY4251)* 175°F/79°C Yellow Figures 200°F/93°C Green 135°F/57"C Orange PENDENT 155°F/68°C Red 8.0 (TY4951) 1/2" and 115°Fns•c Yellow 1,2,3,5 NPT UPRIGHT 200°F/93°C Green (TY4851) 286°F/141°C Blue 360°F/182°C Mawe NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratorlea, Inc. fOr use in Cenada (C-UL). 3, Approved by Factory Mutual Research Corporation (FM). 1,2,4,5 4. Approved by the Loss PnMntlon Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354-01-E. NIA NIA 1, 2, 5 1,2, 3, 5 1,2, 5 1**,2*•, 3 .. , 5 .. 1"',2 .. *,5** NIA NIA NIA 6. VdS Approved (For details oontaot Tyoo Fire & BuHdlng Products, Enachede, Netherlands, Tel. 31·53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coaled, wax Coaled, and Wax over Lead Coaled Sprinklers are noted lo be UL and C-UL Listed, the sprinklers are UL and C-UL Llaled • CorroalOn Rasislant Sprinklers. Where Lead Coated, Wax Coated, and wax over Laad Coaled Sprinklers are noted 1D be FM Approved, the aprtnkktra are FM Approved as Corroeion Resistant Sprinklers. * lnatalled with Style 10 (112" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 150°F/66°C Maximum Celling Temperature. *** Frame and deflector only. Listings and approvals apply 1D color (Special Order). NIA: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS TFP151 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING CLOSURE 2-7/B"DIA. ;l (73,0mm) 2-1/4" DIA. ---:-1 (57,2mm) TI 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) ~j_ FIGURES 1-1/4" (31,8 mm) 3/4" (19, 1 mm) SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH 1W0-PIECE 314 INCH TOTAL ADJUSTIIENT STYLE 10 RECESSED ESCUTCHEON 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING CLOSURE 5.6 K-FACTOR, 112 INCH NPT 2-7/8" DIA. =;l (73,0mm) 2-1/4" DIA. ---j (57,2mm) JI 3/4" (19, 1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2mm) ~j_ SERIES TY-B FIGURE6 1-5/16" 33,3 mm) 13/16" (20,6 mm) SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON B.O K-FACTOR, 314 INCH NPT Page5of8 WRENCH RECESS (END 'A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B' USED FOR 3/4' NPT MODELS) FIGURE7 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS D PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURES W-TYPE 1 RECESSED SPRINKLER WRENCH Page8of8 Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175psi(12,1 bar) Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/bar112} K = 8.0 GPM/ps1112 (115,2 LPM/bar1'1) Temperature Ratings Refer to Table A FlnllhN Sprinkler: Reessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame . . . . . . . . . . . . . Bronze Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . . . . . . Beryllium Nickel w/Teflont Bulb ............... Glass Compression Screw . . . . . Bronze Deflector . . . . . . . . . . . Copper Bushing (K=2.8) . . . . . . . Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Pendent and Uprl~t Sprinklers are intended for fire protec- tion systems designed In accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The Serles TY-B Sprinklers must be Installed in accordance with the follow- ing instructions: NOTES Do not Install any bulb type sprinkler If the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135"F/57°C to 3/32 Inch {2,4 mm) for the 360"F/182"C temperature ratings. A leak tight 112 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 314 Inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7Nm) of torque is to be used to install sprinklers with 314 NPT con- nections. Higher levels of torque may distort the sprinkler Inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment In the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Serie• TY•B Pendent and Up- right Sprlnklert must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be Installed In the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 1 O inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Agures 1, 2, 3, and 4 the W-lype 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable Is to be applied to the wrench flats. When Installing wax coated sprinklers with the adjustable Cresoent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws ol the wrench should be opened sufficiently wide to pass over the wrench flats without damag- TFP1S1 Ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After Installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- Ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1 /8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms Is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which It can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, In order to prevent the Installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc* cessful, additional wax can be ordered In the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The S8rle• TY.a Recu•d Pendent Sprinklers must be installed In ac- cordance With the following instruc• lions. Step A. After Installing the Style 1 0 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-lype 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench iS to be applied to the sprinkler wrench flats. Step C. After the celling has been in- TFP1S1 stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the series TY-8 Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Serles TY-B Sprinklers must be maintained and serviced in accord-ance with the following Instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that It controls, permission to shut down the a"ected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which Is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have riot operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid dam- age to the sj>rinklers • before, during, and after installation. Sprinklers dam- aged by dropping, 5'riking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual Inspections are rec- ommended to be Initially performed for corrosion resistant coated sprinklers, after the Installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, Instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in• spection, testing, and maintenance of their fire protection system and de- vices In compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The In- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified lnspecilon service in accordance with local requirements and/or national codes. Limited Warranty Page 7 of 8 Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, Improper installation, corro- sion, or which have not been Installed, maintained, modified or repaired in ac,. cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at !Yeo Fire Products' sole option. 'fyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. ~S8u~Nle8~t>.ttt.r'rN lmf. TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE· GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE EQBEQQING WARRANTY IS MAQE IN LIEU QF ANY AND ALL OTHER WARRANDESEXPRESBQB IMPLIED.INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOB A PARTICULAR Pl/B· l!DSEa .. • Pa9e8of8 TFP151 ~N57-XXX-X-XXX I I I MODEL/SIN SPRINKLER TEMPERATURE RATING 530 2.8K UPRIGHT (112"NPT) TY1151 NATURAL BRASS 135 135°F/57"C 531 2.8K PENDENT (1/2"NPT) TY1251 4 WHITE POLYESTER 155 155°F/68°C 570 5.6K UPRIGHT (1/2"NPT) TV3151 3 WHITE (RAL001or 175 175°F/79°C 571 5.6K PENDENT (1/2"NPTI TV3251 9 CHROME PLATED 200 200°F/93°C 590 8.0K UPRIGHT (3/4"NPT) TV4151 7 LEAD COATED 286 286°F/141 °C 591 8.0K PENDENT (3/4"NPT) TV4251 6 WAX COATED 360 360°F/182°C 286°F/141°C MAX. 560 8.0K UPRIGHT (1/2"NPT) TV4851 8 WAX OVER LEAD 561 a.OK PENDENT (1/2"NPT) TV4951 286°F/141°C MAX. TABLES * Eastem Hemisphere sales only. PART NUMBER SELECTION SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprlnklar Anemblla with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table B). Receued Etcutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 112" (15 mm) Style 10 Chrome Plated. . . . . . . . . PIN 56-701·9-010 112" (15 mm) Style 10 While Color Coated . . . . . . . . . . .. .. . PIN 56-701-4-010 112" (15 mm) Style 10 White RAL9010" . . . . . . . PIN 56-701-3-010 1/2" (15 mm) Style 10 Brass Plated......... . . PIN 56-101-2-010 3/4' (20 mm) Style 40 Chrome Plated. . . . . . . . . PIN 56-700-9-010 3/4' (20 mm) Style40 White Color Coated . . . . . . . . . . . . . . . PIN 56-700-4-010 3.'4' (20mm) Style 40 White RAL9010* . . . . . . . PIN 68-700-3-010 314' (20mm) Style 40 8nlse Plated........... PIN 56·700-2-010 • Eutem Hemltphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387. Specify: W-lype 7 Sprinkler Wrench, PIN 56·850-4-001 . Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries TY-B Sprinklers, PIN (specify). Black for 135°F . . . . . . . . . . . . P/N 58-085-1-135 Red for 155"F . . . . . . . . . . . . . PIN 58-08&-1-155 Yellow for 175°F . . • • • . . . . PIN 58-0SS-1-175 Blue for 200"f and 286°F ................. PIN 58-085-1·286 NOTES Each wax stick is suitable for retouch- Ing up to twenty-five sprinklers. The wax used for 286"F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler Is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 150°F). TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqca I Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series EC-8 -8.0 K-factor Extended Coverage (Light Hazard} ales: Tel: ( 414) 570-5000 / 00) 558-5236 Fax: (414) 570-5010/ BOO) en-1295 Pendent and Recessed Pendent Sprinklers General Description The Series EC-8 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are Intended for use In automatic sprinkler systems designed in accordance with standard Installation rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprin- klers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon pro- vides up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent po- sition, whereas, the Style 40 provides 3/4 Inch (19, 1 mm) of vertical adjust- ment from the flush pendent position. The adjustment provided by the Re- cessed Escutcheons reduces the ac- curacy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING• that provides cautions with respect to handling and Instal- lation of sprinkler systems and com- ponents. Improper handling and In- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate In a fire situation or cause it to operate prematurely. Page 1 of 6 tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing Is not representative of all possible cor- rosive atmospheres. Consequently, it Is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings tor any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Serles EC-8 Extended Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, In addition to the standards of any other authorities having jurisdiction. Failure to do so may Impair the per- formance of then devices. The owner Is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY 4232 -Pendent, 8.0K TY 4232 is a redesignation for C4232. JANUARY, 2005 Technic Data Approvals UL and C-UL Listed. M and NYC Ap- proved. (Refer to Tab e A for complete approval information including corro• sion resistant statu . The approvals apply to the servic conditions indi- cated in the Design riteria section.) Maximum Working ressure 175 psi (12, 1 bar) Pipe Thread Conne tlon 314 inch NPT Discharge Coefflcle ts K = 8.0 GPM/ps1112 (115,2 LPM/bar112) TFP223 Page 2 of 6 Components: 1 • Frame 2 • Button 3 • Sealing Assembly 4·Bulb 2 5 • Compression Screw 3-""1'7.i111.111,...,_v~ 6 • Deflector* * Temperature rating is 4 Indicated on Deflector. •• Pipe thread connections per ISO 7/1 can be provided on special request 6* FIGURE 1 1-7/16" (36,5mm) TFP223 SERIES EC-8 (TY4232) EXTENDED COVERAGE PENDENT SPRINKLERS SPRINKLER FINIS (See Note4) HAZARD TYPE TEMP. BULB NATURAL WHITE* LIQUID BRASS POLYESTER LIGHT PENDENT 135°F/57"C Orange 155°F/68°C Red 1, 2, 3 5 Refer to Table B for UL and C-UL Sensitivity Rating REC.PENDENT 135°F/57°C Orange and w/ Style 30 Esc. 155°F/68°C Red 1, 2, 3 5 Refer to Table C for FM Sensitivity Rating REC.PENDENT 135°F/57°C Orange w/ Style 40 Esc. 1ss°F/6a0c Red 1, 2, NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as rroslon Resistant Sprinklers. 5. Approved by the City of New York under MEA 113-04-E. "Frame and Deflector only. Listings and approvals apply to color (Special Order). Temperature Ratings 135°F/57°C and 155°F/68°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame ............. Bronze Button . . . . . . . . . . . . . Bronze Sealing Assembly . . . . . . . . . . . . . . . Beryllium Nickel w/Teflont Bulb . . . . . . . . Glass (3 mm dla.) Compression Screw . . . . . ................ Bronze Deflector . . . . . . . . . . . . Brass t Registered trademark of DuPont TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature Is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The Series EC-8 Extended Coverage Pendent Sprinklers must only be In- stalled in accordance with the applica- ble UL and C-UL Listing or FM Ap- proval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installatio , as applicable (Ref. Table A, B, and ). UL and C-UL Llstln Requirements 1. The Series EC-8 prinklers may be used for the cove ge areas shown In Table D, based n maintaining the minimum specif! flow rate as a function of covera e area and haz- ard group for all the sprinklers in the design area. 2. With respect to h at sensitivity, the Series EC-8 Sprin lers can be used with unobstructed onstructlon con- sisting of flat, s oth ceilings (in- cluding bar Joists) with a maximum pitch of one in si as defined and permitted by NFP 13. 3. The minimum allo able spacing be- TFP223 AREA STYLE 16x 16 Pendent 16 X 16 Style 30 Recessed 16 X 16 Style 40 Recessed 18 X 18 Pendent 18 X 18 Style 30 Recessed 18 X 18 Style 40 Recessed 20x20 Penclent 20x20 Style 30 Recessed 20x20 Style 40 Recessed OR: Quick Response SR: Standard Response NIA: Not Applicable 135°F 155°F QA QA QA QR QA QR QR OR QR SR QR SR OR SR OR SR SA SA TABLEB SENSITWITY RATING FOR UL AND C•UL LISTING OF SERIES EO-S SPRINKLERS 135°F 155°F AREA STYLE 16 X 16 Pendent QR OR 16 X 16 Style 30 Recessed QR NIA 16 X 16 Style 40 Recessed NIA NIA 18 X 18 Pendent QR OR 18 X 18 Style 30 Recessed QA NIA 18 X 18 Style 30 Recessed NIA NIA 20x20 Pendent QR QR 20x20 Style 30 Recessed QR NIA 20 x20 Style 40 Recessed NIA NIA QR: Quick Response SR: Standard Response NIA: Not Applicable TABLEC SENSITIVITY RATING FOR FM APPROVAL OF SERIES EO-S SPRINKLERS tween the Series EC-8 Sprinklers, to prevent cold soldering, Is 8 feet (2,4 m). 4. The Series EC-8 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for ex- tended coverage pendent sprin- klers. FM Approval Requirements The Series EC-8 Extended Coverage Sprinklers are to be installed in ac- cordance with the applicable Factory Mutual Loss Prevention Data Sheet. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spacing, and deflector-to ceiling distance. Page 3 of 6 lnstallat The Serles EC-8 Sp inklers must be Installed in accordan with the follow- ing instructions: NO Do not Install any bul type sprinkler If the bulb is cracked o there Is a loss of liquid from the bulb. ith the sprinkler held horizontally, a mall air bubble should be present. T diameter of the air bubble Is approx/ ately 1/16 tnch (1,6mm). A leak tight 3/4 Inch T sprinkler joint should be obtained th a torque of 10 to 20 ft.lbs. (13,4 to 2 ,8 Nm). A maxi- mum of 30 ft.lbs. {40 7 Nm) of torque is to be used to i tall sprinklers. Higher levels of torq may distort the sprinkler Inlet with nsequent leak- age or impairment of he sprinkler. Do not attempt to co pensate for in- sufficient adjustment fan Escutcheon Plate by under• or o ,-tightening the Sprinkler. Readjust t position of the sprinkler fitting to sui Step 1. The sprinkler ust be installed with the deflector par llel to the mount- ing surface. Pendent sprinklers must be installed in the pe dent position. Step 2. After installln the Style 30 or 40 mounting plate ( r other escutch- eon, as applicable) er the sprinkler pipe threads, and ith pipe thread sealant applied to t e pipe threads, hand tighten the s rinkler Into the sprinkler fitting. Step 3. Wrench tight klers using only the -Type 3 (End A) Sprinkler Wrench. W ench tighten the recessed pendent prinklers using only the W-Type 4 S rlnkler Wrench. The wrench recess t the applicable sprinkler wrench (Re . Figure 4 and 5) is to be applied to the prinkler wrench flats (Ref. Figure 1). Page 4 of 6 DESCRIPTION TY4232 (K=8.0) PENDENT 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3. 785 1pm 1 psi "' 0.06895 bar 1 gpm/ft2 = 40.74 mm/min AREA 16x 16 18 X 18 20x20 TABLED GPM 26 33 40 PSI 10.6 17.0 25.0 FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 1/2:1:1/8' (12,7±3,2 mm) {73,0mm) 2·1/4' DIA. {57,2mm) 1/2' (12,7 mm 1/4" (6,4 mm) 1/8' FACE OF SPRINKLER FITTING ~~~:;;;::1~,,~li,.rr-i!..tJ;· -fi= ~~~:T \ 1-1/4' {31,8 mm) 1' (25,4mm) FIGURE2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 /NCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 9/16:1:1/4" (14,3:1:6,4 mm) FACE OF SPRINKLER FITTING \ (73,0mm) t 2·1/4" DIA. If-.. ,.,-) 3/4' (19,1 mm) 1/4" (6,4 mm) 1·5/16" (33,3 mm) 13/16" (20,6 mm) FIGURE3 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON -······· --··---·------------ TFP223 "FITTI E" TOWARD KLER Care an Afainfen The Series EC-8 Sp lnklers must be maintained and ser iced in accord• ance with the followin instructions: NO Before closing a fire otectlon system main control valve r maintenance work on the fire prote tion system that it controls, permiss • n to shut down the affected fire p action systems must be obtained om the proper authorities and all pe onnel who may be affected by this a lion must be no- tified. Sprinklers that are to nd to be leaking or exhibiting visible s ns of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coat d, or otherwise altered after leaving t e factory. Modi- fied sprinklers mu t be replaced. Sprinklers that have een exposed to TFP223 corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coaling, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA .25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (1 O) years against defects in material and work• manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (1 O) years from date of ship· ment by Tyco Fire Products. No war• ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac· cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FQBEGDING WARRANTY IS MADE IN LIEU DE ANY AND ALL QTtfEB WARRANTIES EXPRESS 08 IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS EQB A PARTICULAR PU8- EDS£ Page 5 of 6 Ordering Procedu e When placing an orde , indicate the full product name. Pie se specify the Sprinkler ldentificatio Number (SIN), quantity, and tempera ure rating. Refer to the Price List for c mplete listing of Part Numbers. Contact your local di ributor for avail- ability. Sprinkler Assemblle with NPT Thread Connection . Specify: TY4232, (sp cify temperature rating), Extended C erage Pendent Sprinkler with (spe ify finish), P/N (specify). 135'F/57"C Natural Brass ............. PSN 50-801 • 1-t 35 White Coated ............. PSN 50-801-4·135 White (RAL901 OJ' .......... PSN 50-801·3·135 Chrome Plated ........... PSN 50-801·9·135 155"F/68"C Natural Brass . . . . . . .. PSN 50·801-1-155 White Coaled ............. PSN 50·801·4-155 White (RAL9010)'. . .. PSN 50-801·3·155 Chrome Plated ... PSN 50·801-9-155 *Eastern Hemisphere s les only. Recessed Escutche n: Specify: Style (30 o 40) Recessed Escutcheon with (sp city finish), P/N (specify). Style 30 Rece88ed Escutc eon Chrome Plated ............ PSN 56-705-9-011 White Color Coated ...... 1 .• PSN 56-705-4-011 White (RAL9010)' ....... · 1· . PSN 56·705-3-011 Brass Plated .............. PSN 56•705-2-011 ! Style 40 ReceHed Escutc eon Chrome Plated ............ PSN 56·700-9-010 White Color Coated ........ PSN 56-700-4-010 White (RAL9010)" .......... PSN 56-700-3-010 Brass Plated .............. PSN 56-700·2·010 *Eastern Hemispheres les only. Sprinkler Wrench: Specify: W-Type 3 S rinkler Wrench, P/N 56-895-1-001 Specify: W-Type 4 Re essed Sprinkler Wrench, PIN 56-875--001 .. ,. Page 6 of& TFP223 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 46 INCORPORATED CORONA, CA • (909) 737-5599 FIG. 68 WIDE THROAT TOP BEAM "C" CLAMP WITH LOCKNUT Size Range -3/8 thru 7/8 inch rod. Function -For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals -Conforms to Manufacturers Stand• ardization Society SP-69, type 19. Finish -Plain and Electro-Galvanized. Order By • Figure number, rod size, and finish. Note -Do not overtighten set screw. FIG. 69 BEAM CLAMP RETAINING STRAP Size Range -3/8 thru inch length. Material -Carbon Steel Function -To offer more secure fastening of beam clamp to beam when danger of movement might be expected. Approvals • Underwriters' Laboratories listed when used with Talco U.L. Listed Fig. 65 and 66 Universal Beam Clamp. Finish • Mil. Galvanized and Stainless Steel. Order By -Figure number, type, length "A", and rod size being used with beam clamp. Note· Minimum return on Strap: 1". 2 3 5/8 <;~/4( >· HOLE SIZE 7/16 ·9/li6:c:, A STOCK SIZE A FINISH 16gaxl t Mil. Galv . .. i:wi~r.;;,;Jtifi~¼iiiitffi#.-lliiij;i;,, 11/16 14gaxl-1/4 t Mil. Galv. ·13/16 . . ~-~lt1tfffiilirt-1la~ 3/8 -7/8 specify 12gaxl-l/4 t Mil. Galv. ·-------------·----··· •• INCORPORATEO CORONA, CA • (909) 737-5599 FIG. 65 AND FIG. 66 45 REVERSIBLE C•TYPE BEAM CLAMPS· 3/4" AND 1·1/4" THROAT OPENINGS Size Range -(Fig. 65) 3/8 thru 5/8 inch rod (1/2 thru 10 Inch pipe). SiH Range -(Fig. 66) 3/8 thru 5/8 inch rod (1/2 thru 10 inch pipe). Material -Carbon Steel with hardened cup point set screw and jam nut. Function -Recommended for hanging from steel beam where flange thickness does not exceed3/4" (Fig. 65) or 1-1/4" (Fig. 66). Features • All steel c·onstruction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engage- ment. Application Note -Fig. 65: add 1-1/2'' to rod length when clamp is to be used in set screw up position. Fig. 66: add 2" to rod length when clamp is to be used in set screw up position. Approvals • Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 23, and Manufacturers Standardization Society SP-69, type 19 and 23. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet #13, 3/8"' rod will support 1/2 thru 4N pipe, 1/2" rod will support 1/2 thru 8" pipe. Finish • Plain, Electro-Galvanized, HDG, and Stainless Steel. Order By • Figure number, rod size, and finish. ROD SIZE A , B --l ~ D ~A J___ : : : E --I I j -r--'----~' I I C I I _J__ I : B~}-A l.___ ~ : I : E -.- c I J_ LJ FIG. 65 TABLE PIPE SIZE B C D E FIG.65 FIG. 66 MAX. APPROX. REC. WEIGHT F LOAD LBS. PER 100 3/8 1/2 -4 1 -3/16 3/4 1 7 /16 1 1500 28 11'~ , • • 5:;:-:,8;. ,,.J..,tJX~ • ~il\lr iH;ij(,i~~AW!~i!filtA-f~i:r~~il; 5/8 10 1 -1/2 3/4 1 9/16 1 -1/4 FIG. 66 TABLE ROD MAX. APPROX. SIZE PIPE REC. WEIGHT A SIZE B C D E F LOAD LBS. PER 100 120 INCORPORATED CORONA. CA• (909) 737-6589 FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range· Pipe size to be braced: 1" through 8" Sch. 10 and 40. Pipe size used for bracing: 1" and 1-1/4" Sch. 40 JPS. Material • Carbon Steel Function • For bracing pipe against sway and seismic disturbance. The pipe attachment com- ponent of a sway brace system: Fig. 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe per NFPA #13*, forming a complete sway brace assembly. Features • Can be used to brace Schedules 10 and 40 JPS. Field adjustable, making critical pFe-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting -type sway brace fittings. Comes individually packaged with illustrated installation instructions -sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector that necessary minimum torque (5 lb/ft) has been achieved. Application Note • Fast Clamp need not be field assembled. Position Fast Clamp and· tighten two hex nuts until leaf spring flattens. *Length of bracing pipe per National Fire Protection Association, Pamphlet #13, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7'-2". 1-1/4" Schedule 40 bracing pipe maximum 9'-2". Approvals • Underwriters' Laboratories listed. Note· Must be used with Tolco U.L. Listed 900 Series attachment. Finish • Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By • Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. ,--- 1 I...- ------] ------ -----.. I I I t< I I I ! ___ J,_; '-.../ ----·--------- Schedule-10·/Schedule-40· Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-I 0/Schedule-40 gives you the extra quality assurance you demand. Our Sch-IO (l ~11-811} pipe and Sch-40 (1 "-2~") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-I O/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with Che zinc coating specifications of ASTM A-123. Superior Coating Our advanced fonnula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test NPS ln;mm 1· 25 1¼' 32 1½" 40 2' 50 2½' 65 NPS ln;mm 1' 25 1¼' 32 1½" 40 2' 50 2½' 65 3' 80 4' 90 5' 125 6' 150 8' 200 "tqca I Row Control Q allied TUBE & CONDUIT Sch-40 Specifications Nomlnal 1.0. WI. Wt. (HZO fllle~) Pcs/ W~lft(21') W\11.111 (24') WIJI.lft (25' ln;mm lbs/Ft; Kglm Lbs/Ft; Kg/m lift Lbs;Ka lbs;Kg lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 , 2,940 26.6 2.5 3.05 70 1,120 1,280 1,334 1.380 2.270 2.93 51 2,431 2,778 2,894 35.1 4.36 4.36 51 1,103 1,260 1,313 1.610 2.720 3.61 44 2,513 2,872 2,992 40.9 4.0 5.37 44 ·1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 52.5 5.4 7.63 30 1,043 1,192 1,242 2.469 5.790 7.86 19 2,310 2,640 2,750 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications Nominal 1.0. WI. WI. (H20 RIied) Pcs/ W~ift (21 '} WIJUII (24') WIAJfl (25'] ln;mm Lbs/Ft; Kg/m Lbs/Ft Kg/m Lift Lbs;Kg Lbs;Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 27.9 2.1 2.70 91 1,213 1,385 1,445 1.442 1.810 2.52 61 2,319 2,664 2,760 36.6 2.7 3.75 61 1,052 1,208 1,252 1.682 2.080 3.04 61 2,664 3,045 3,172 42.1 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 54.8 3.9 6.28 37 930 1,063 1,108 2.635 3.530 5.89 30 2,224 2,542 2,648 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 108.2 8.3 17,53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 16'1.5 13.8 34.27 10 885 1,012 1,053 8.249 16.490 40.15 7 2,424 2,770 2,885 209.5 24.5 59.75 7 1,100 1,256 1,309 ® <8> @ Listed Approved Listed 16100 S. Lathrop• Harvey, IL 60426 Customer Service: 11350 Norcom Rd.• Phnadelphia, PA 19154 2525 N. 27 th Ave. • Phoenix, AZ. 85009 (800) 882-5543 Fax 708-339-1806 S5-3 I .. ,,r~ . BRKCCO ~ ... ) ,. FOR USE WITH WET OR DRY SYSTEMS. GAUGES HAVE A BRONZE BURSON TUBE MOVEMENT IN A STAINLESS STEEL PLATED CASE (UNLESS OTHERWISE NOTED). 3-1/2" DIAMETER. U.L. AND F .M. APPROVED (UNLESS OTHERWfSE NOTED). . ., . --~ . .'. ," i . .. .. , .. , .·.I", .... • • 1'~800~543-4194 AR• • AS REQUIRED Brecco Corporation GAUGES Part No. GAAWSS350 GM8S250 GAWP200 GAAWP350 ►GAUGES~ Deacriptian AIR/WATER 0-300PSI WI STAINLESS STEEL CASE AIR WI RETARD 250 PSI ~1/2" OtA, WI STAINlESS STEEL CASE 2" RESIDENTIAL GAUGE 300 PSI (NOT U.l. OR F.M. APPROVED) AIR/WATER WI PLASTIC CA.SE L .. ,:-:••·' I••-, • '' , .. -1• • • •, eox,c ... Qtv 80 80 100 60 Fax: 1-877-474-9248 breccocorp@earthilnk.n~ 062000 INCORPORATED CORONA, CA • (909)737-5598 FIG.909 30 NO,THREAD SMVEL SWAY BRACE AITACHMENT Size Range -1 and 1-1/4 inch bracing pipe. For brace pipe sizes larger than 1-1/4 inch use Talco Fig. 980. Material -Carbon Steel, hardened cone point en~ging screw. Function -The structural component of a sway and seismic bracing system. Features- • No threading of the bracing pipe is required. • Open design allows for easy inspection of pipe engagement. • All steel construction eliminates deficiencies associated with malleable type attachments. • Fastener can be mounted to all surface angles. Application Note -The Fig. 909 is used in conjunction with the Talco Fig. 1000 "Fast ClampTM ", Fig. 2001, or Fig. 4(A) pipe clamp, and joined together with bracing pipe. Install per NFPA #13 and/or Tolco's State of California OSHPD Approved Seismic Restraint Manual. Installation -Extend bracing pipe through opening. Tighten cone point engaging screw until head bottoms out. Approvals -Underwriters Laboratories Listed per 203A (UL). Approved by State of California Office of Statewide Health, Planning and Development (OSHPD). Finish -Plain, Electro Galvanized and HDG. Order By -Figure number, pipe size and finish. lmportllnt Note -The Fig. 909 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the U.L Listing requires that the Fig. 909 must he used only with other To/co bracing products. NATIONAL AND INTERNATIONAL PATENT APPLICATIONS IN PROCESS. MAX. MAX. PIPE SIZE A B H* HORIZONTAL DESIGN LOAD LBS. HORIZONTAL DESIGN LOAD LBS. W/WASHER APPROX. \Vf./100 1 6 1-5/8 17/32 2015 2765 1-1/4 6 1-5/8 17/32 2015 2765 * Available with hole sizesxo accommodate up to 3/4" fastener. Consult Factory 91 97 0 ® State of California OSHPD APPROVED n Standard wuhcr (Pig. 115) required for 2765 lb. design load INCORPORATED CORONA, CA• (1108) 737-55IKI FIG. 4 STANDARD PIPE CLAMP Size Range • 1/2 thru 30 inch pipe. Material • Carbon Steel Function -To carry piping where little or no insulation is required. For heavier loads, see Fig.4H. Approvals • Listed by Underwriters' Laboratories 2. 8 inch (1/2 • 1-1/2 inch listed if E.G.). Approved by Factory Mutual Engineering, 1/2 • 8 inch. Federal Specification WW-H-171E, type 4, 1-1/2 thru 24 inch and Manufacturers Standardization Society SP-69, type 4. Maximum Temperature -750°F Finish • Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By -Figure number, pipe size, and finish. 1-1/2 4-1/4 1/2 1-1/2 18-1/2 1 10-1/4 10-1/4 1/Sxl 5/16 19 MAX. REC. LOAD LBS. APPROX. FOR SERVICE TEMP, WEGKr 650°F 750"F PER 100 500 445 29 ,__,,__,__ __ _ ••••••• -·----------- INCORPORATED CORONA. CA• 1909) 737-6599 • , l , '• l , , ~ ., 1 ; ' • • ' • 1 1 1 • , • l ,, .,, I <-"' , ' ' f •• •' • -. •~ , • ' I • • ' ' FIG. 51 AND FIG. 52 SIDE BEAM BRACKETS (CONT.) A I FIG. 51 FIG. 52 FIG. 51 for NFPA Rod and Fastener Sizing PIPE SIZE 1/2 • 2 ROD SIZE 3/8 A 2 FIG. 52 • 6 Hole Bracket ROD SIZE 3/8xl/2 A 2 B 3/4 B 1-1/16 C 2 C 2 HOLE SIZE H-1 H-2 7/16 7/16 HOLE SIZE STOCK SIZE 3/16x2 H-1 H•2 H-3 9/16 7/16 9/32 FIG. 56 TAPPED SIDE BEAM CONNECTOR Size Range• 1/2 thru 4 inch pipe (3/8 inch rod). Material • Carbon Steel Function • Practical and economical bracket used to support hangers from steel or wood beams. Can be used with concrete shot-type inserts. Tapped hole allows easy adjustment of hanger rod. Approuals -Underwriters' Laboratories listed and Factory Mutual Engineering approved for 1/2 -4" pipe. Fini.sh -Plain, Electro-Galvanized, HOG, and Stainless Steel. Order By -Figure number and finish. Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8 inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch fastener. STOCK SIZE 3/16x2 APPROX. WEIGHT PER 100 35 APPROX. WEJGHT PER 100 35 APPROX. PIPE SIZE ROD SIZE HOLE SIZE STOCK WEIGHT A B C D E F G H J SIZE PER UlO 1/2. 4 2-5/8 3/8 1 3/8 1-1/16 l•l/8 7/16 9/16 1-1/4 l/4xl 20 41 Submittal Data Sheet Super 40@/Dyna-Thread® Full Line Sch-40 Replacement Super .l[l/Oyna-Threud sprinkler pipe represems on engineering udvn11ce111e111 for 1he sprinkler pipe im1usuy II i:ombincs Ihc safely 1rnd longel'iry of iraditionul Sch-40 pipe wirh qualiry anL1 ,;uperi,w hydraulic :1dvnnrnge,. Comparison to Schedule 40 Super 40/Dynn-Threads inside diamm.r is up t0 3.6% 1.irger 1h.111 Sch-40 giving ii superior hydraulics. Also, when used in combi11a1ion wich D)'nu-Flow pipe. I.lawn sizing often t)ccms. Super 40/Dyna-Thread is full)' listed nncl approved UL, ULC, and Flvl for fire sprinkler applicmions. The life expec1ancy of Super 40/Dynu-Thre~d und Sch-40 ore equal b;:ised on th~ c:1lcula1ed wall thicknesses per UL (see CRR). The consiste111 qu~liry of sreel u,.ed w m.11:e Super 40/Dyn:1-Thre,1d focili1,11es smoo1h 1hre:1ding i1nd lower mainIenance costs. Th.: e.,1em1r ur Supcr -10/Dyna-Thre.id is pm1ec1e<l by a clenn. durable mill coarmg for exIe11ued sl.<!11 Iii~ ,111d e,Isr 11:li111 applic:11io11. With its increaseu s1rength .1nd lighter weigh1. Super40/ o, m1-Thrt,1d rcduc<!s ins1,1lh11ion r.uigue and is ide,11 for re1ro-lit applic,uions. Corrnsirn1 R,:,IsIa11L·e Rarit) tCRRl ,s :1 UL (Underwri1ers L:ibormory) term flir Ihe esrnnaced lil'e 1c.xpecrnnc)' ,11 " pipe j.ii111. This Is bt1sed on th<! calcuhued wall thickness at 1he b~se of the tirs1 exposed rhm11J. a,~umel.l 10 be the 11~;1kest p~1i11I of the pipe length. Super 40/Dyna-Thread and Sch-40 hnve 1he ~ame i:alculaI.:d wall 1hiclrn~sses 111 1his point m1d are both assigned rhe sam~ CRR or 1.00. Comparison to L. W, T. Pipe More wall thickness a1 the 1hre,1d (CRR:a 1.00) gives SujX'r ~O/Dyn:1-Thre,1d b.:ner life expecrnncy rhan light wall rhread,1ble pipe joi1us. Unlike liµhrwall rlm:ad.ihle pipe. Supa 40/D)'nu-Threud ha~ no thread gauge warning. Super 40/ Dvnu-Thn~ad is appmved for s1andurd hanger spac111g (I 5 i1. O.C.J, can be 11sed :is earthquake s1,·:1y ~r:1ci11g. and is safe 10 use :is drops. Super 40/Dyna-Thread is sar'er 10 weld on than many ,.inc-co.ll<!d ligtmvall 1hret1dable pipe produc1s. Super 40/Dyna-Thread is more widely accep1ed than ligh1wall 1hreadable where Sch-40 is specitied. Slamp Her@ Sp~ifications & Approvals Super4ff/Dyna-Thre,1d pi~ is mnnufilctured 10 meeI: ASTl'.l A 135. Grnde A and is in compli:mce \\ i1h NFPA-13. All sizes of Super 40/Dyna-Thread arc ramJ at 300 psi working pressure. Super 40/ Dvna-Thread is UL ,ind ULC Listed for wet, dry ~,id pre-action sprinkler sysrems and FM Appro,•ed for 1ise in \WI ~j•sIems. Super 40/Dynu-Thre:id can b~ "hot-dip" g:1I\':mii.e<l 10 meet FM requiremenI Specifications •=lnthu •=M11lli1: fur Jr) S)'SICll1£. Super 40/Dyna-Thre11d is approv~ll (or ul I 1hreaded coup I ings and l\;elded outlets und is s111t:.1ble for all roll-grooved, nnd plain-end fillings. (See listing inform111io11). /(i;'\ ~ ~ ~ ApproV"J4J Llst•d Product NPS X 1" *25 x 1 1/4" *32 x 11/2" *40 ?" )( - *50 Nominal WVFt Wt/Ft I.D. H:20 Filled 1.080 1.330 1.75 27.4 2.0 2.60 1.408 1.870 2.54 35.8 2.8 3.78 1.639 2.290 3.22 41.6 3.4 4.79 2.104 3,050 4.57 53.4 4.5 6.80 Pcs/ Wt/Lift Wt/Lilt Wt/Lift Lift 2:1.' 24' 25' 70 1955 2234 2327 70 887 1013 1056 51 2002 2288 2384 51 908 1038 1081 44 2115 2418 2519 44 959 1097 1143 30 1921 2196 2287 30 871 996 1037 Americ~n Tube and Pipe wus acquired b)' Allied 1\1be nnd Conduit un February l, 1997. The ~ngineered lightwall and st1111d:ird wall famil)' of "roducts al1~oui:h they l1111·e dill'crenl names are the same in all rcspec1s with regard 10 slrenglh, weighc, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo nrc 1he same product ns Ql'O Dyna Thrend und Super 40. XL is mnnufnclured with Exterior galvanized coaling. IlLT is manul'aclurcd witli Black lacquer coating. ; Project: Sprinkler Contraclor: Date: Engineer: Specification Reference: System Type: Locations: Comments: Grooved IPS Fittings Victaulic fittings are designed specifically for use in grooved piping systems. Victaulic oilers a broad line of fittings in sizes through 24" (600 mm) in a variety of straight and reducing styles. Most standard fittmgs are case of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratmgs conform to the ratings of Victaulic Style 77 couplings. All iittings are supplied with grooves or shoulders to pormit last instaUauon without field preparation. The grooved design permits flexibility for easy alignment. These fittings are nor intended for use with Victaulic couplings for plain end pipe (refer to page 55 for fittings available for plain end applications). Fittings are provided in vanous materials including malleable iron. ductile iron, steel or segmentally welded steel depending on styles and size. Fittings pre painted orange enamel with galvanized optionally available, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or with shoulders confonnmg to standard steel pipe outside c\Jameters. When connecting wafer or lug-type butterfly valves directlV to Victaulic fittings with 741 or 743 Vic-Flange® adapters. checl, disc clearance dimensions wlth l.D. dimension of fitting. Request 07.01. Alternate Materials Stainless Steel -Groovet1 end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5. 40 and Type 304 optionally available) in various sizes. Fitting cencec-w-end dimensions will vazy depending upon type and schedule. Request 17.04 for details. t\,luminum -Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 -8" (25 -200 mm). Request 21.03 or contact Vicraulic for details. Alternate Styles EndSeal® "ES" Fittings - EndSeal fittings are available in 2 • 12" (50 -300 mm) for use with "E:S" grooved pipe and HP-70ES EndSeal or lo'ire-RTM couplings. "ES" fittings are painted green rm easy identification. J<~ndSeal (anj standard) fittings may be easily internaUy coated (by others) for severe service requirements. Always specify "ES EndSeal fittings" when ordering. Request 07.04 for information on EndSeal fittings. Fittings Machined for Rubb~r or Urethane Lining (MRL) -Por severe abrasive services. Victaulic fittings may be rubber or urethane lined (by others). Lming may bf• inside diameter/end (abrasion resistance) or wrap-around ( corrosion and/or abrasion) machined. Request 25.03 or contact Victaulic for specific details. Flow Data Friction Resistance Pipe Inches/mm Equivalent FeeVmeters ol Straight Pipe Pipe ·equivalenl FeeVn>elars al Stralghl Pipe Inches/mm The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of strmght pipe. Fittings not Hsted can be esumated from the data given, for example, a 22½0 elbow is approximately one-half the resistance of a 45° elbow. Values of mid-sizes can be interpolated. 14 90° Elbows No.100 No.10 mo Norn. Actual Std. Long Size Size Radius Radius 1 1.315 1.7 ... 2!; 3~lJ O.!> 2 2.375 3.5 2.5 f,O tlO.~ 11 Otl 3:j: 3.000 4.3 -76.1 1.3 - 3 3.500 5.0 3.8 80 88.fl 15 1? 4 4.500 6.8 5.0 100 114 3 21 1.5 4¼:j: 4,250 6.4 -100.0 Ul 5 5.563 8.5 -125 141.;J 2.6 - 5¼:j: 5.250 8.1 -'/330 2!, - 5¼:j: 5.500 8.5 -'13£17 2.6 - 6:J: 6.250 9.6 -159.0 2.9 .. # Contacl Vlclaulic ror delalls. :J: o.o. Dimension. 45° Elbows Tees No. 110 No.11 W,D Std. Long Norn. Radius Radius Branch Run Size 0.8 -4.2 1.7 6 u.:~ l 3 0.5 150 1.S 1.1 8.5 3.5 6'h.f l)!i 0 :! :~ 6 11 2.1 .. 10.8 4.3 8 07 33 l 3 200 2.6 1.6 13.0 5.0 10 OB O!l 4 ll 15 ?50 3.4 2.1 16.0 6.8 12 ., 11 Ol\ 49 2.·1 300 3.2 -15.3 6.4 14 () 9 47 ~o 2150 42 -21.0 8.5 16 1.3 -134 26 •100 4.1 -20.0 8.1 18 I.ti lJ? 2.5 45il 4.2 -21.0 8.5 20 1:, .. 6.• 2.6 :;oo 5.0 -· 25.0 10.0 24 1 5 76 30 GOO 90° Elbows 45• Elbows Tees No. 100 No.110 No.10 rno No.11 1'1.tD Actual Std. Long Sid. Long Size Radius Radius Radius Radius Branch Run 6.625 10.0 7.5 5.0 3.0 25.0 10.0 160 3 30 ? ~~ 1 5 0.!l 76 ::10 6.500 9.6 .. 5.0 -25.0 10.0 1,551 2.9 -l!l , ,, :ill 8.625 13.0 9.8 6.5 4.0 33.0 1:::.0 :!191 -10 3.0 c..o 12 101 40 10.750 17.0 12.0 8.3 5.0 41.0 li".O :.1':'30 52 3.7 2.:i 1.5 12.5 5.:! 12.750 20.0 14.5 10.0 6.0 50.0 20.0 3~3.9 6.1 ~4 30 1 R 1ti 2 61 14.000 II 23.0 # 18.0 60.0 H.0 35..~ 15 ,, 7.0 # ~.5 1113 !J.~~ 16.000 # 26.0 # 20.0 70.0 2(•.0 ~Ol,.4 # 70 ff 61 213 fi'I 18.000 II 29.0 # 23.0 80.0 2:: .. 0 45'.'.0 ;, 0.6 t ~o 24.4 70 20.000 II 33.0 II 26.0 90.0 2!:-.0 :;oa.o II 101 * 7.9 27 4 7.(, 24.000 # 40.0 # 30.0 30.5 34.0 6100 # ·12 2 # 01 Q;~ 104 t I MNIHl"tWllM:rt a :·er· n·eemtftJ,MMfW Style 07 Zero-Flex® Rigid Coupling 2 -12• Sizes 14 -16" Sizes 18 -24" Sizes ¥, -12" Sizes 14 • 22" Sizes 24" Size Nom. Max. Dimensions -Inches/mm Aprx. Size Work Press. Wgt. Each Norn. Max. Dimensions -Inches/mm Aprx. Size Work Press. Wgl. Each Inches/mm PSl'/kPa X y z Lbs./1,g Inches/nun PSl"/kPa X y z Lbs./kg 1 750 2.45 4.13 1.88 1.6 '!> :-, l ;·~) 1.'i:?. lib 4H (t ~ :Y, 1,000 2.13 3.63 1.75 1.1 ,. (i000 :l.J !t' .1.1 ,)! .. 1¼ 750 2.60 4.00 1.8B 1.6 -1.' :11:!i ili5 lil? d!J ll 7 1 1,000 2.36 3.88 1.75 1.3 :l::: ,i9ui dO ~~~ -1-1 (l(i l'h 750 2.94 4.8'1 1.88 1.6 J(l :11,·., :, t :~:! 40 d: 1¼ 1,000 2.63 4.63 1.75 2.0 _{~) li~lO d~ llli -1-1 1Hl 2 750 3.19 5.44 1.88 2.3 :,o ~"'1"1S ~1·1 111 .m 'I() l½ 1,000 3.00 5.00 1.75 2.1 ~r-= tl!JlU 'H 1:':· ·~ Ill 2½ 750 3.88 6.13 l.88 2.8 ,i!i ~) 1 :··:., !111 ,,,6 -IB 1 .l 2 1,000 3.63 5.63 1.75 2.6 :1l' ,;9l).1 ~1~' 1 ~-~ II 1:1 3:j: 750 4.25 5.75 1.86 3.6 !)1,"'"!, 10n 146 ,!.' ll.i 2½ 1,000 4.25 6.25 1.75 3.1 Qt, li~l()O 1m, 1 :1~ l .1,-1 14 3 750 4.56 6.81 1.88 3.1 BO :) l :'~) lhl 1-·· .:m 1.1 .. , 3 :J: 1,000 4.31 6.31 1.75 3.6 ,il'IO.l llil H.}l) -1~ 1,;, 4 750 5.81 6.25 2.06 4.6 HlO :>'t:'~ ,,w :'10 52 ::_1_2 3 1,000 5.00 7.00 1.75 3.5 dll ,moo 12: 1 .";i, 4~ 1 b 4¼:j: 750 5.56 744 2.06 5.2 :i. 1 ~·:1 1,11 Hi9 !i:' _1,1 3½ 1,000 5.63 8.00 1.75 5.6 ;JO liEl(K.1 lail;j -~l).) .1.1 ·,~ 5 750 7.06 9.75 2.06 7.1 1. 1~ ~ :-,,-.•~ 17'H ::~;; !l:1 3 ., 4 1,000 6.38 8.50 2.00 6.6 1UP ll~U'.l 1 ti:~ -~, ,; ~1 :1,.1- 5¼:j: 700 6.36 9.18 2.06 7.4 .tB~'!, 17-4 .!:?3 s:• ;; J 41/.,:j: 1,000 5.88 8.06 2.06 7.0 (ieltll) 1,l!l >l\!1 ~'I} .1:· 51kt, 700 6.94 9.42 2.06 7.6 .~tl1~l ·1:n .'3~) ~:? 5-1 5 1,000 7.63 10.25 2.00 10.6 -~:, li~lUil HJ.i !,ill !,1 •Ill 6 700 6.00 10.75 2.06 8.7 l~iU ,JIJ~!!l 20:~ :r::~ 5~~ _q 51/, + 1,000 7.34 9.20 2.06 IO.O .,,,on 1thl .!J,I !)? ·• ~, 6¼:j: 700 7.85 10.16 2.06 9.2 l(t-~!1 l!l!l l'~,~l ,;:, J ., 5½!:j: 1,000 7.60 9.44 2.06 1·1.0 L)9()\i 1\);1 ;1.m :,~1 :-.ti 6½:j: 700 8.00 10.75 2.06 7.2 ..Jfi_..l!j ''0.1 i·::.; !>2 Ji 6 1,000 9.00 11.50 2.00 11.8 1:,(' O!l!K) :I?;) _J~).I M a-I 8§ 600 10.25 13.50 2.50 14.9 ·,oo l l]ll :"'i,O .i.U lj,:1 Li ~~ 6¼:t: 1,000 8.50 10.38 2.06 13.2 \iS-kXl ~lli .J(-i.l :,:' litl 10§ 500 12.66 16.75 2.56 25.0 .:1.:iLl Jt,~~n .r--l.ll) 6a ;, J 6½:j: 1,000 9.19 11.50 2.06 13.2 tiOOll 2:i:, ... ,,::: :•:.:.' ,;fl 12§ 400 14.88 18.50 2.56 28.2 :II.kl /;;,U .,.-,1 i:·,; u~ 1? H 8§ 800 11.38 14.50 2.38 20.1 ;>u,;J ::1:100 :~~l JlW.i 1iO ~,. l 14 300 16.19 19.75 2.94 32.8 .l:11) .'\kk, 41'1 !"~-'' 7!, lJ fl 10 § BOO 13.50 16.75 2.50 28.3 '.'5(l !,!,.X, :,M.1 .['!) (i..,1 l?li 16 300 18.38 21.75 2.94 41.2 4lX1 :'Uli:> .tt;;' ;K,i,,; ·;-!) Ill; 12 § 800 15.50 19.00 2.50 34.2 .iL'lt:1 !,SJ(l .l!l-1 IB3 li,J 1!")!t 16 300 20.69 23.68 3.06 54.2 ,1:,0 :-"(hi~• ~:>ti tilXi 71'! !~ c 14 300 16.63 20.00 2.86 35.6 :J:,o ;~06~ 4.':! !,1kl ::1 Hi I 20 300 23.00 27.38 3.06 67.2 :,l).I :-,itia :,:)4 ml!, ~ .. .., . "' .)U" 15 300 17.88 21.25 2.88 48.8 :, ·!~ ;~uo~; -i ~ >-1 ;,.I() ts .•:• I 24 250 27.13 31.50 3.13 76.2 iill(l 1:~·a ,lti!) JOil 7~l 3•1 l' 16 300 19.00 22.38 2.88 51.1 .:,i(' :.~Ju:, -111:l ~}\Xi .·:1 .,.,., .·.,. :j: 0.0. 01menQl011. • Refer lo notes on page 7. § Avallable toJ.I.S. dunensoon 18 300 21.25 24.38 3.13 64.4 .J!)L) ~'(Ilic' !i41l l-;Hl -~, :'!}:' 20 300 23.50 27.50 3.13 91.2 :10u ?O,ic• ~,n. \lU~) "'!) 41 I 22 300 25.63 30.00 3.13 92.0 !1~0 ~Or:! lk1l td~, ;·n 41: 24 250 27.63 31.38 3.13 94.0 (illtl 172:i ... o~-;!F /[I .J:'li :t 0.D. D,mens10n. • Rere, to noles on page 7. § Available 10 J.I.S. d1men;,on. 8 ·-Sit per Flo®/ Dyna-Flow® ~:...ligh Strength Steel ripe·· The original high-strength /ightwa/1 sprinkler pipe with hydraulics superior to Schedu/e-:J.O. Super Flo/Dyna-Flow pipe is the "original" high-strength lightwall sprinkler pipe. Super Flo/Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-IO pipe. Lightweight, easy to cut and easy to handl~ for installation. Super Flo/Dyna-Flow is a valuable addition to any fire protection system. Superior Hydraulics With an inside diameter of up to 11 % larger than Schedule-40 and up to 7 % larger than Schedule-10, Super Flo/ Dyna-How pipe hydraulics are exceptional. ,._. .. ger I.D.s enable Super Flo/Dyna-Flow, \ ..i1d related components, to be down- sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to ''Super Flo/Dyna-Flow Hydr-aulic Data Tables." -~ • Coatings & Fabrication • • Super Flo/Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paimable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No ,,,._..cial process or equipment are needed fabrication and installation. Specifications x=lnchas •=Mlltllc Product Nominal WVFt Wt/Ft NPS 1.0. H20 Filled X 1 • 1.191 0.830 1.31 *25 30.3 1.2 1.95 X 11/4" 1.536 1.059 1.87 x32 39.0 1.6 2.78 x 11/2" 1.728 1.667 2.71 *40 43.9 2.5 4.03 X 2" 2.203 2.104 3.79 ,r,50 56.0 3.1 5.64 X 2 1/2" 2.703 2.564 5.10 * 65 68.7 3.8 7.59 X 3" 3.314 3.387 7.18 *80 84.2 5.0 10.69 X 4" 4.310 4.473 10,86 *90 109.5 6.7 16.16 x6" 6.403 7.714 21.70 *150 162.6 11.5 32.29 Specifications & Approvals Super Flo/Dyna-Flow pipe is manufactured to meet ASTM A- 795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Liste.d. Listed Approved Listed Super Flo/Dyna-Flow is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plajn-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Super Flo/Dyna-Flow is now available "hot-dip"galvanized and has been specifically approved by FM for dry systems uses. Pcs/ Wt/Lift Wt/Litt Wt/Lift Lift 21' 24' 25' 91 1586 1812 1888 91 719 822 856 61 1356 1550 1615 61 615 703 733 61 2135 2440 2542 61 968 1107 1153 37 1634 1868 1946 37 741 847 883 30 1615 1846 1923 30 733 837 872 19 1351 1544 1608 19 613 700 729 19 1784 2039 2124 19 809 925 963 10 1620 1851 1928 10 735 840 875 ' ' Additional Benefits • Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. • Provides stability needed to comply with standard hanger spacing (15 ft O.C.} per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and.welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications . . • G;f allied 11JBE & CONDUIT "'..-~,iu-1 upcmlflllli'r 16100 S. Lathrop Harve)', IL 60426 11350 Norcom Rd. Philadelphia, PA 19154 2525 N. 27th Ave. Phoenix, AZ 85009 Cu$tomer SorYi¢o: 1-800-797-6210 Fax 70A-339·1B06 INCORPORATED CORONA, CA • 1909) 737-65911 53 , , , • , \, . , , , , . t, ~ • , ' I . • • ' • , l • FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range • 3/8 thru 7 /8 inch rod in 1 inch increments. Material -Carbon Steel Maximum Temperature • 750°F Finish • Plain, Electro-Galvanized, and Stainless Steel, Order By -Figure number, rod diameter, rod length, and finish. FIG. 100 ROD SIZE 3/8 V2 5/8 3/4 7/8 MAX. REC. LOAD LBS, FOR SERVICE TEMPS. 6SO"F 750"F 610 540 1130 1010 1810 1610 2710 2420 3770 3360 ALL THREAD ROD FULL LENGTHS Size Range • 1/4 thru l·l/2 inch rod in 10'-0" lengths. Material• Carbon Steel Maximum Temperature -750°F Finish • Plain, Electro-Galvanized, and Stainless Steel. Order By • Figure number, rod diameter, and finish. MAX. REC, LOAD LBS, APPROX. ROD FOR SERVICE TEMPS WEIGHT SIZE 6S0"F 75D"F PER 100 FT. 1/4 240 215 12 • ~-tR 11z,.r. '',,l'>m•:•1;i;..~~<!l.n·-::1>~:i:': th0!?:;IIJ.\;, • .. ,w.;,:~'1:Mt\.~•:r..~~l\~~~- 1/2 1130 1010 53 !i:i~sl~~~~ 3/4 2710 2420 123 !~~t'.iiAS!lwW~-HliiiJ 1 4960 4420 222 ~~f~---1-1/2 11630 10370 510 -rr©.o· 1DLC INCO"-P-O"ATe;lJ CORONA, CA • (Q09) 7l7 -6~99 FIG. 2 ADJUSTABLE RING HANGER 15 FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range • 1/2 thru 6 inch pipe. Material -Carbon Steel, Mil. Galvanized to G-90 specification. Function • For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approuals • Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature -650°F Finish -Mil. Galvanized and Stainless Steel. Order By • Figure number and pipe size. PIPE SIZE ROD SIZE A B C A STOCK SIZE MAX. REC. LOAD LBS. C APPROX. WEIGHT PER 100 FIG.l? FlG. 2 NFPA