Loading...
HomeMy WebLinkAbout1855 TULE CT; ; 83-88; PermitIll z 0 ~ a:: ~ u Ill C C I[ 0 u 0 -5 I Ill z ~ z 0 .:: C Ill z Ill CL 2 0 u Ill i:r: Ill :,,: a:: 0 3 ·1l O I hereby afllrm that I am licensed under pr011lalona of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license Is In lull force and effect. lie No ______ Class _____ _ I hereby affirm that I am exempt from the Contrac· tor's License uw tor the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which re-quires a permit to construct, alter, Improve, demolish, or ~~~~ta: s!~~u~it'°ro11i:!s~~~= ::;:~rf~a\~rs ho,nsed pursuant to the pn!Ylsions of the Contractor's :-:,;~ ti,~;~JJ~;s =~~,g~':':~:r:. empt therelrom and the basis for the alleged exemption. Any violation of Section 7031.5 by an applicant for a perml1 sub-jects the applicant to a civil penally of not more than five hun· dred dollars ($500). .,, I, as owner of the property, or my employees with wages as ,uir sole compensation, wm do the work, and the struc-ture i? not intended or ottered for salt! (Sec. 7044, Business and Professioos Code: The Contractor's License uw does ::r:g,,~n~0 ,;~ :O":rs~J',.':.1i=f 1:1~~~~~s";:. employees, provided that such improvements are not Intend· ed or ottered for sale. If, however, the building°' lmprc menl is sold within one year of completion, the owne_r;bui will havo the burden of proving that he did not bui prove for the purpose of sale). V' □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 704~. Business and Professions Code: The Contractor's License uw does not apply to an owner of property who builds or im-J)(oves thereon, and who contracts lor each protects with a contractor(s) lteense pursuant to the Contractor's License UIW). □ As a homeowner I am illlf)roving my home, and the lollow· ing conditions exist: 1. The work Is being performed prior to salt!. 2. I have lived In my home tor twelve months prior to compft!tion of this wort<. 3. I have not claimed this exemption during the last three years. □ lamexemptunderSec. ______ ,B&P.C. for this reason ____________ _ D I hereby affirm that Iha.ea cert,hcate of consent to self-,nsure, or a certificate of WOfkers· Compensation Insurance. or a certified copy thereof (Sec 3800. Labo< Cooe). POLICY NO -----------· COMPANY Q Copy IS hied with the City 0 Certified CoPY 1s hereby furnished CERTIFICATl OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed 11 the perm11 15 tor one hundred dOllars ($100) Of less) 0 I certify that in the performance ol the work tor wtuch this pemut 1s issued. I shall not employ any person m any manner so as to become sub1ect to the Wor1<ers' Compensallon Laws of Cahfomia NOTICE TO APPLICANT If, alter malun~ lh,s Cert, hcate of Exemption, you should become sub1ect t? the Workers' Compensatton prov1s1ons of the Labor Code. you must forthwith comply w1lh such prov,s,ons or this perm11 shall be deemed re\loked 0 I hereby athrm that there 1s a conslruction , len<J,ng aoency tor the per1ormance ot 1he work fOf wtuch th,s perm11 1s issued (Sec 3097, C1v1I Codel Lenders Name ___________ _ lender's Address __________ _ USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WI I HIN SHAUt:U Attt:A ANU Ut:l,;LAHA I IUNS. CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT 1200 Elm, Carlsbad, California 92008-1989 (619) 438-5525 JO.~ Ai];.s-Tu! e er C 'Mt s i:,fi d. OWNER'S NAME /dtCi.vP £Jew A£~ l d5Y0 S~R;P70NE 0 iYs':;L7i/~EScf-.-[//t?ls J4d (Y!J L'tJ I BLOCK I SUBOIVISION lASS~ AV. ST.,OATE OF APPLICATION RO. CONTRACTOR (!)tv;t1ER-., CONTRACTOR'S ADDRESS DESIGNER 'll frc:-/1., oEstGNER's ADDRESS BUSINESS LICENSE # 7i(tf:111 CONTRACTORS Pl10NE I zoiil r UCENSENO. PLAN 1.D. # LICENSE• STANDARD PLAN# OESIGN&WS PHONE PERMIT NUMBER i?~t~ BLDG USE CODE BUILDING SO. FOOTAGE '2.-oob ~ u: >-<ii 0 C. E Q) f- I -0 18 c co -~ _L_ c.l, "v__t;,, F/P FLR ELEV. NO n .P A..~-=-,..,,, £_ ~ -vO NO t/QBIW,~J I EDU I 000}~'1:lf ~/0!/~5? ti "-•~'°g: as I "t~. '~ CENSUS TRACT GP LAND USE PARKING SPACE RES UNITS REDEVELOPMENT AREA I GRADING ~ERMIT ISSUED v □ ND vO NO I Not Valid Unwss M#chine ~rtifi«i QTY.I PLUMBING PERMIT -ISSUE 7 !::!--l QTY., MECHANICAL PERMIT. ISSUE I 3'-SUMMARY/ACCOUNT NUMBER ,,.. l//. I EACH FIXTURE TRAP I '7-,"'2,,-. :ra 7 I INSTALL FURN. DUCTS UP TO 100,000 BTU I lf. -I BUILDING PERMIT 01-00·00-8220 ~--r~ _, EACH BUILDING SEWER OVER 100,000 BTU SIGN PERMIT 01·00·00·8221 EACH WATER HEATER AND/OR VENT BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 01·00·00·8806 / I EACH GAS SYSTEM I TO 4 OUTLETS I -7._ r,1 I sotLER/COMP_RESSOR 3-15 HP I ~ -~ I TOTAL PLUMBING 01·00·00-8222 I ~ 4 -I I EACH GAS SYSTEM 5 OR MORE I -I ~ETAL FIREPLACE ELECTRICAL 01·00-00-8223 .,,.,, EACH INSTA~ .. ALTER, REPAIR WATER PIPEVENT FAN SINGLE DUCT MECHANICAL 01·00·00·8224 _.- I I EACH VACUUM BREAKER I ! I MECH EXHAUST -HOOD/DUCTS MOBILEHOME 01·00·00·82.25 I 7 WATER SOFTNER RELOCATION OF EA FURNACE/HEATER MOBILEHOME PARK INSP EACH ROOF DRAIN (INSIDE) I i I I I SOLAR 01-00-00·8226 --_j -TOTAL PLUMBING T ~-✓ TOTAL MECHANICAL !Cl STRONG MOTION 80·92·33·0519 .J, Sb FIRE SPRINKLERS 01·00·00·8227 QTY. ELECTRICAL PERMIT· ISSUE 5"'-QTY. SOLAR • ISSUE r PUBLIC FACILITIES FEE 32-00·00·8923 ----- BRIDGE FEE NEW CONST EA AMP/SWT/BKR COLLECTORS SCHOOL FEE • DISTRICT I PH 3 PH STORAGE TANKS carlsbad 80-92·21 ·0519 EXIST BLDG EA AMP/SWT/BKR ROCK STORAGE Encinitas 80·92·22·0519 1 PH 3 PH REMODEL/ALTER PER CIRCUIT r-PUMP San Oieguilo 80·92·23·0519 PLAN CHECK rEE San Marcos 80·92·24·0519 TEMP PO LE 200 AMPS ""'-1" A } . OVER 200 AMPS --/,,,7l -ll~~ ,~ 1~.~I} TEMP OCCUPANCY 130 DAYS) 11 ' TOTAL ELECTRICAL l 10.---TOTAL SOLAR TOTAL FEES PAYABLE I £/.61,, It, 1 HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY ~ Expiration Everypermit,-,.dbytheBuildlngOfllclalundertlleprowieionaoflflil CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE cc::,,a11all •• ome null and VOi • DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS au 1Z ..:..=="~~ ced wtttltn 1 ISSUED:. TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON· o, 1" AN OSHA P£AMIT IS REQUIIIED FOR EXCAVATIONS OVER .5• 0-DHP AND DEIIOUTl0N OR CONSnu:noN OF STIIUClUIIES OV£R 3 SlOfllES IN HEIGHT STRUCTION, WHETHER SPECIFIED HEREIN OR NOT I ALSO AGREE TO SAVE INDEMNIFY A D KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS A ____ APPROV D BY EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF TH -"':2..-" , • GRANTING OF THIS PERMIT -~...-<.1 BY PHC3.NE O ~ I I ~ C a: 0 "' "' Q) "' "' <( I ~ .2 ai >- rn "' Cl) (.) 0 rt co <ii 0 §: Q) (.) C co C u: C Q) ~ C, 0 0 Q) C. "' C ~ .c 3:: ------------. BUILDING ,,,,-- /,. .17.IJ,. y>J(A FIELD INSPECTION RECORD • FOUNDATION .... / IV',--....., REQUIRED SPECIAL INSPECTIONS REINFORCED STEEL -MASONRY INSPECTION REO IF INSPECTOR'S CHECKED APPROVAL GUNITE OR GROUT ' SOILS COMPLIANCE FLOOR & CEILING SUB FRAME PRIOR TO FOUNDATION INSP SHEATHING I ---~~~ ~A STRUCTURAL CONCRETE FRAME OVER 2000 PSI EXTERIOR LATH lNSULATION ' ~.;'"l.t f"✓-2 ,.__/ PRESTRESSED CONCRETE INTERIOR LATH & DRYWALL ,/ "'.,, <>-" ~ POST TENSIONED CONCRETE PLUMBING FIELD WELDING -- SEWER AND BL/CO : HIGH STRENGTH PLUMBING UNDERGROUND BOLTS PLUMBING TOP OUT SPECIAL MASONRY ' --- TUB AND $HOWER PAN ' GAS TEST . PILES CAISSONS ELECTRICAL ,. ·,• TEMPORARY POWER ' .J ,. ELECTRIC UNDERGROUND . C I• ROUGH ELECTRIC .. ELECTRIC SERVICE ·,. - BONDING , , . G. F. I. -SMOKE DETECTOR '1 MECHANICAL I . ' --. - DUCT & PLEM., REF. PIPING ' I. .. -, .... ,_ ... HEAT -AIR COND. -SOLAR SYSTEMS -•· ' . VENTILATING SYSTEMS . .. " ~ CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HA VE BEEN APPROVED. , . JOB SITE FINAL _,, ./'? PLUMBING ., ... ' ~._, /N ELECTRICAL ./h' ~ f/7..:::~ MECHANICAL A!\ 1/ ~ ,n J"i ~'/ ,, ,~ ,....11 : ,.,., GAS -,__ BUILDING / \" SPECIAL CONDITIONS CERT OF OCCUPANCY ISSUED '. i l. l r: , - • . • x-3 r )f <g '- INSPECTOR'S NOTES DATE 9,2:7.~ ~,._,~,~,\r.\"+r~ -- ,-•• "!. •• .5·-· ' ,,. . ~°'-l_ I I. ~ . I -~ ~ ....... ' . • • '. " • I,: " I . " .... .:! .. ' .-. ':.. .... r ... , __ .., "--C ... -~ . 1. . ' ,, r (\ , ·• ~ • II . c, ~ . '.v ' ,.t ,, ' ' I " • \ . ~ ) .. , - ·--.: "' ~ ' -.. - ' -,,/' C < ' •. \ - .. . \ .· ., - -- ; : .... ~ .,-·.. ,1,1# '. . -.. j ; ~-, . • -.. . '· ' . ' . . ,~ ':,,_~, ... ,.: . ' . -~ ·\· --,.. • ' . . ~~--_' ~· ·-t. ; ,, , r.n • i ,:.r,:, • .; \_iji \~':; .: 1 •~ \ \.; t-·' !;·.; • .•-<; ·-. '· --· '"'\ ' I C "') \ \ J _\ l ', ,K'! ' ' . " . .... C ---• '!"' , ... :• 7hg-j/?)9-1VS Cu/t,,L, SuBS~FJL,blf CrJma,y tUJTH 71-:Je ~£763" //:::::. /1-/V~~ IS /JO£?&-O OA./ -7h&- /SVY} £).7.J-770 /7-) /?t-19-N : // /, /~/~IZ 7Z5 //V.5f/6C77{)A/ 87' pl!:;, C /fa/ :;t:;v 5 pec--70 /2. / 77:/e .5? IL s b~IJv&---t:;72 S~~ M.Ot/JS'&r IM~·g{//LOJ//./C, O~/C/8-1-~ /IU w12/.77.1Vtt 1 -;7/'7-JJ-T 7/Je 5:JIL-.S J9;0£:} /8v/f/~7tJJV /A?.-5Jc£/V /42~ CCJ>?- S/5ren7/ tu1717 -!'he //U7Z:::-rvr c:JJ===- 71,e Cbr. d-& /5771~ S/~ i?P~/2-A ~ f3u /7r.le;qc; 5:J/L.S C)tcr7Z ~IVC , J;IZV//l.JI? I I I - Ci4Z/ff)J2iv10 11 ~6---=-G_~~L ~e, ~~:ll (!.D_ ~J2r ~-5 /~ ?~, ~~ ..5,e. ~ ~aoo P.S/;::::, 'l3cTrn2 <.=---:SS&L? L-o ~ 7UC.' JURISDICTION: _______ DATE 3/4J /Y ~ ?ROJECT ADDRESS: /l?SS -rul...i: Coil'.?f- TO: P@?l/Cfhvr' PLAN CORRECTION SHEET SINGLE PAMILY AND DUPLEX DWELLINGS Plan Check No. 83-BB Date plans received by jurisdiction re{....3fa1 nate plans received by plan checker -,-JC .2L_t s' Date initial plan check completed /t/e: b;d p~ f'()REWORD: PLEASE READ ~ ?lan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The items circled below need clarification, mod ification or change. All circled items have tc be satisfied before the plans will be in ccnformance with the cited codes and regulations. Per Sec. 303 (cl, 1979 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. ~ Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been ~turned to you by the jurisdiction, tG, eJU?; wpr To fac1litate rechecking, please identify, nex~ to each circled item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans. Indicate on plans the name of the legal cwner and name of person responsible for the preparation of the plans. Sec. 302(bl 0 APPLICANT COPY ~y COPY D PLAN CHECKER COPY / Submit fully dimensioned plot plan drawn to scale showing location size, and use [). of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes and approximate finish floor elevations for all structures and show elevations at all corners. Sec. 302(bl7. Indicate distance from center-line of street or alley to property line and distance from curb to property line. Sec. 302(bl7 Plans, specifications and cal ulations shall be signed by a California State licensed engineer or architect. (California ~ r. I':_ Business and Professions Code) u~~~ f' IRF. PROTECT IO l.., ·_,\v\ _ _..,.im.: __ ~ ___ :::=~~~: ' Wa lls closer than shall be one-hour have no openings, parapets when the 1,000 square feet Sec. l 709(al 3 feet to property lines fire-rated construction, and shall have 30 inch building floor area exceeds on any floor. (Table 5-A 1 ✓ Projections, including eaves, may not extend 7 · more than 12 inches into the 3 foot setback from the property line. Sec. 1710 and y. Sec. 504(bl Projections, including eaves,shall be one- hour fire-resistive construction, heavy timber or of non-combustible material if they project into the 3' setback area from the property line. Sec. 1710 L.i!..-/Show location of permanently wired smoke ✓--detector. sec. 1210 C:. ROOM SIZES I l,IGHT I VENTILATIONS ANO GLAZING ,v--;:;ne room must contain a minimum of 150 square /" feet of superficial floor area. Sec. 1207(b) • '~abitab le rooms, other than kitchens, shall / 0 ~~ntain at least 70 square feet of floor • area . Sec. l207(bl ~indow area must teat least 1/10 of the floor area and a minimum of 10 square feet per Sec. l207(al. Appears to be deficient ln ,/ Openable window area must be l/20 of the // 0 • floor area and a min1mum of 5 square feet. In bathrooms, laundry rooms and similar rooms. Minimum 1s 1.5 sq.ft. (Sec.1205(a) :./. One-half of all required window area must / be openable in Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if r equired windows / are not provided. Sec. 1205(a) No habitable room, other than a kitchen, shall be less than 7'0" 1n any dimension. / ~c. 1207(c ) ~how that ce1l1ng height for habitable corns is a minimum of 7'6". Sec. 1207(al }1. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0". Sec. l207(a) )~. Provide 30" clear width for water closet compartments and 24" clearance in front of water closet. Sec. l7ll(b) Is. I ,16. /,. I I ~o cooking room shall be used for sleeping purposes, unless complying as an efficiency living unit. Sec. 1208 Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Sec. 5406 Glazing in shower and tub enclosures (including windows ) shall be tempered, laminated or approved plastic. Sec. l 7 l l ( f ) ( g) Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". Sec. 1204 Eaves and cornices may not project into a required yard more than 2 inch7s for each foot of yard width if required windows open into the yard. Sec. l206Cd) A mezzanine is an intermediate floor and may not have a floor area exceeding 33 l /3 percent of the total floor area in the room below, and the mezzanine floor must have a clear height of 7 feet, above and below.and must have 65\ of the long side open to the room below. The loft you show does not comply as a mezzanine floor and is, by Building Code deflnltion, a story ____________ +---lt'- Handrails shall satisfy the following: a. Provide handrail for stairways over 30" high when serving a single dwelling. Title 24, Sec. T25-22 (b) b. Handrail shall be 30" to 34" above the nosing of treads. Sec. 3305(jl Handrail projecting from a wall shall have a space not less than l l /2" between the wall and the handrail. The han{.gri~portion of handrail shall be not ess t an l -f7 4----?ior more tban z• ln erois-sectional dimensloru;--- ~05~h~r---- ._/ Every s~way landing shall have a dimension, / •• measured in the direction of travel, at least equal to the stair-*ay width. Sec. 3305(g) A door may open over a stairway landing provided the door, in any position, does not reduce the clear area of the landing, in the direction of stairway travel, t less than one-half the required width f the stairway. Sec. 3 S(g) 3)11,IZ.eQ'O· ? /. C nOMe,<? S'"-'' ~ ' A door may open inwar the top step of a stairway provided the tOp'-.11,.e.tt«r-r.~m,-C-- more than 7 1/2" lower than the floor level . Sec. 3303(i)2 SA. Provide details of winding stairway. a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from the side of the stairway. b. Maximum rise is 9 inches. c. Minimum width is 30 inches. Sec. 3305(d) (see attached) Provide spiral stairway details: a. Minimum run is 7 1/2 inches at a point from where the tread is the narrowP.st. b. Maximum rise is 9 l /2 inches. c. Minlmum headroom is 6 feet 6 inches. Sec. 3305(f) _-.,-. ., (see attached) ~~-r._i'(\).'"l"I\ ~Qv,,i.t>D<..-..K, D. EXITS, STAIRWA'iS, ANO RAILINGS ..\) I q ) Spiral stairways :nay not be used for required~. / '-l: ~ exits when the area served is greater than 1"5~• !"loors above che second scory shall have 400 sq. ft. sec. 3305(fl L "':'.?'~ "t½•i\\-it-l~q, not less Chan 2 exits. Sec . 3302(a) r!~ ~\') •h1.C..-1..1,>-4<:,C / 57 ~piral stain,ays must have a clear wafk1n~ . . Required exit doorways shall be not less space of 26 inches between the column and than 36" ln •-,1dth and not less than 6'-8" handrail. Sec. 330S(fl 1~ height, and shall be capable of opening ac least 90 degrees. Sec. 3303(e) . 59 Provide I.C.B.O. Reasearch Report and Numbe% for metal stairway, or submit plans and 4Y. Provlde 36" high protective railing for . calculations and approved fabricator / porches, balconies, and open _sldes of landings. registered with the Building Department Maximum opening between railings shall be or note that the stairway fabrication shall less than 9". Sec. 1716 be done under special inspection per the Show how guardrail connection details are adequate to support 20 pounds per lineal f oot ac a rlght angle to the cop rail. Table 23-B Provide stalrway and landing detallS. Sec. 3305(b) & (c l a . Maximum rise e• and minimum run is 9". b. Minimum head r oom is 6'-6". c . approved fabrication plans. Sec. 306(a)4B and Sec. 306(fl ./In buildings over 2 stories in helght, provide /'" 3/4 hour fire-rated assemblies for all openings in the exterior wall below or Wlthin 10 feet horizoncally of an exterior stair- way. An exit balcony wich 2 separaced stalrways is exP.mpt . Sec. 3305 ,/Excerlor scoirways shall not proJect into / 0 ~he 3 foot: secback fr om the property l lnes. Sec. 330S (n l ---,,-----· -......, (' • " .GI_ . 2,"\ /\JO\IE G-••w • "30 • Y"lo. \ ~ti ) ~ "IC 'Z, ... ~ \'-·' 0 ·<-' / 0 ':'he •-,alls~f-~of the en;losed usable space under 1nter1or stairs shall be protected on the enclosed side as required for one-hour tire-resistive construction. Sec. 33051ml /M1nl.lllum construction specifications shall /•· be made a part of the approved plans. • (See attached) !:. ROOFING /specify roof pitch. U-: Roof pitch is not adequate for roof type / specified. Specify minimum pi tch of ____ _ /4pecify roof material and application. ~ •/specify I.C.B.O. approval number for roof A /-·; aterials not covered in use. pecify roof slope for drainage or des1gn . o support accumulated water. Sec. 32071a) /2how roof drains and overflows. Sec. 3207 (al "'.;/Provide skylight details to show compliance .✓• with Sections 3401 and 5207 or provide ICBO approval number. ,/ Provide plastic roof panel details to show ./ •• compliance with Section 5206 or provide ICBO number. B. Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least SOI of the required vent is at least 3 feet above ceiling joists. Sec. 320S(cl MASONRY Provide fireplace construction details or note construction to be per attached fireplace $tandard drawing. Sec. )707 0 /Show veneer support and connections comply / 0 ~1th Sec. 3002, 4,5,6, and Sec. 2516(a) regarding ties and 19 wire in horizontal joints or note construction to be perattached sheets 30-1 or 30-2. /show height and construction details of all masonry walls. Chapter 24 ~-Note that cleanout openings shall be"provided / at the bottom of all cells to be grout fil l ed • over 4' in a single pour. Cleanout shall be sealed before grouting, after inspection. ec. 2415 Show floor and roof connections to masonry walls. Connection shdll resist 200 pounds per lineal foot or the actual design load, /whichever is greater. Sec. 2310 Ji . Provide material specifications for mortar, / ~rout, masonry and reinforcing steel. /Sec. 2403 11. Show how masonry house walls retaining earth / ' are to be waterproofed. Provide detail. Note that special inspection of the masonry will be required for _____________ _ RAGE AND CARPORTS l .Ga;age requires one-hour fire protection the garage side of walls and ceiling ommon to the dwelling. Table S-B Sec.S03(b)1 l elements supporting floor above garage o have one-hour fire-resistive protection on the garage side. Sec. SO). Beams and posts, not within the wall or ceiling con- struct1on, must comply with UBC, Table 43-A, or be minimum 6" dimension beam and minimum 8" by a• post. Show l 3/8" solid core self-closing door for openings bet~een garage and dwelling. Sec. 503(d) 103. Garages are not permitted to open into a room u_sed for sleeping purposes. Sec. 1104 Openings between carport and residence require self-closing doors and stationary windows. Sec. 1214 Show garage f raming section, size of header over garage opening, lateral cross bracing at plate line and method of bracing garage front. Chapter 23 NOTE: Minimum plywood diaphragm ratio is 3 1/2 to l or 2'8". Table 24-I Doors between dwellings and attached garages may swi ng in either direction provided the difference in floor elevation between the dwelling and garage does not exceed 7 1/2 inches and provided the door is not used as the primary means of egress from the building. If the difference in floor elevation exceeds 7 1/2 inches, or if the door is used as the primary means of egress from the building, additional steps or landing must be provided in accordance with stair~ay requirements, and the door must not swing over the depressed level. (see 330J(i)2 and JJOS (g) . Provide 18" rai sed platforms for any FAU, water hea ter, or any other device which may generate a f lame or spark. Note tha t continuous fire wall protection shall be installed behind raised platform(s) prior to framing platform. FOUNDATION RE UIREMENTS Note on plans that"A soils engineer shall eva-luate any unanticipated uncompacted fill or expansive soil or other soil problems disclosed during construction•. Sec.J06(a)l2. Submit soils classification determination by a licensed engineer or architect based on observation, tests, borings, or excavations, and containing comments on the degree of expansiveness, compressibility and bearing alue. Sec. 2905 Note on the plan the soils classification, whether or not the soil i s expansive, and ote the allowable bearing value. Sec. 2905 The foundation plan does not comply with the soil report recommendation for this project. ___________________ _ Provide notes on the foundation plan listing the soils report recon11nendations for foundations. slab and building pad preparation. Note on the foundation plan that "Prior to the Contractor requesting a Building Department foundation inspection, the soils engineer shall advise the Building Offic ia.l in writing that: 1. the building pad was prepared in accor- dance with the soils report: 2 . the utility trenches have been properly backfilled and compacted, and: 3. the foundation excavations, forming and reinforcement comply with the soils report and approved plan.• '/ Provide spread foocings for concentrated /J• loads designed for 1,000 PSF so1l bearing or per bearing value as decermined by an engineer or architect. Chapter 29 Show height of all foundation walls. Chapter 23 Show height of retained earth on all Eoundatlon walls. Chapter 23 Show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29 Note on plans that wood shall be 6" above finish grade. Sec. 2417(cl 7. Note on plans that surface water will drain away !rom building and show drainage patter~ and key elevations. sec. 290S(fl ~imension foundation per Table 29A. TABLE NO. 29-A-FOUNOATIONS FOR STUD BEARING WALLS-MINIMUM REQUIREMENTS Dll"IN OF FOUNDATION WIDTN TNICKN£SS HLOW NUMIII TNICIINESS OF o, OF NATURAL OF FOUNDATION WALL FOOTINC FOOTINC SUIF&Cl STOlllS (lldll) (lncftll) (lncllll) OF GROUND AND FINISN cONc1m UNIT GUDE MASONH (lncllll) 1 6 6 12 6 l:? 2 8 8 15 7 18 3 10 10 18 8 24 SOTES: WberT un1Uual condition• ot frost COGCiltionJ ar• found. footincs •nd foundations ,hall be u r~uirtd in S~ion 2907 (al. • The flTOWld under the floor may be ncavated to the ele\'ahon of th• top of the foo11n11. /!1i. Show foundation sills to be pressure treated, or equal. Sec. 2517(cl 3. 13,3. Show foundation bolt size and spacing. / ..,,....-sec. 2907lel 1,14. Specify size, ICBO num.ber and manufacturer / of power driven pins. Show edge and end distance and spacing. Sec. 306(fl Show size, imbedment and location of hold down anchors on foundation plan. Sec. 2312(fl Note on plan that hold down anchors must be tied in place prior to foundation inspection. Sec. 2 312 ( f ) Show adequate footings under all shear walls. Sec. 23ll(el Show stepped footings for slopes steeper than 1:10. Sec. 2907(cl _,,1~9 . Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Sec. 2517 ~ Show pier size, spacing and depth into undisturbed soil. Table 29-A ✓i: Show minimum under floor access of 18"x 24". Sec. 25 l 7 t•~-Show minimum under floor ventilation equal to l l /2 sq. ft. for each 25 lineal feet of exterior foundation with openings as close to corners as practicable to provide cross ventilation on at least two approximate- ly opposite sides. Sec. 2517 Show all joists, rafters, beams, and posts 2" to 4" thick to be No. 2 Grade Douglas Flr-Larch or better. All posts a nd beams s• and thicker shall be No. l Grade Douglas Flr-Larch or better. (Table 25-A-ll Show wall bracing. Every exterior wood stud wall and main cross partition shall be braced at each end and at least every 25 Eeet of length with lx4 diagonal let-in brace or equivalent. Sec. 2518(gl5 / 162. Note cross bridging or blocking. Floor I 164. joists and rafters more than 12" i~ depth and spanning more ~han 8 feet shall be supported laterally by bridging at intervals not exceeding 8 feet. Sec. 2506(gl Show blocking at ends and at supports of floor joists, and for rafters at exterior walls. Sec. 2506(gl Show solid blocking at ridge line snd at exterior walls on trussed roofs. Sec. 2506(g) I 1,65. Show double joists. Floor joists shall be doubled under bearing partitions running I parallel with the joists. Sec. 2518(dl 5 16 . Show rafter ties. Rafter ties shall be spaced not more than 4 !eet on center where rafters and ceiling joists are not parallel. Sec. 2518 (h) y o. lJl. Show rafter purtin braces to be not less than 45 degrees to the horizontal. Sec. 2518(hl Show 1/2" minimum clearance between top plate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed.) Show double top plate with minimum 48" lap splice. Sec. 2518(gl 4 Show nailing will be in compliance with Table 25-P. Provide fire stops between stories, between top story and roof space, at ceilings and floor levels in interior and exterior walls, in mansard roof or eyebrow so no concealed or furred space is greater than LO' horizontally or vertically, between stair stringers at top and bottom and between studs along and in line with stair run adjoining stud walls and partitions, at perimeter of sliding door pockets, between chimney and wood frame using metal or incombustibles for the fire stop and at other places that could afford passage of flame. Sec. 2517(!1 /1,72. Show stud size and spacing. Maximum al low- able stud heights: 2"x4"@ 16" is 14': 3"x4"&2"x6•~ 16"o.c. is 20". Sec. 2518(gl2 .Y). Note an A.!.T.C. Certificate of Compliance fo r glued laminated ·wood members shall be given to the Building Inspector prior to erection. Sec. 306(fl Detail all post co beam and post to footing connections. Sec. 2517(cl 4 Specify nail size and spacing for all shear walls, floor and roof diaphragms . Indicate required blocking. Maintain maximum diaphragm dimensLon ratios. (Tables I,J,Kl. Show 3"x4" or 2"x6" studs i n first story of three story building. Sec. 2518 (f l Provide truss details and truss calculations. Provide roof framing plan. Sec. J02(al7 Provide framing sections through ______ _ Section 302(al 7 l~Specify all header sizes !or opening over /. 4' wide. Sec. 2518(gl 7 ,/1· Provide calculations for __________ _ Section 302(a l 7 '~In areas sub3ect to water splash and in r£· exterior locatLons, wood columns and posts shall be s~pported by ~iers pro3ecting at least 2" above the finished grade and shall bear on a metal base plate or treated wood unless the columns or ?OSts are foun-dation grade redwood or cedar. Sec. 25171cl 4 ,/.how location of attic access with minimun 7•· :ize 22• x 30". Sec. 3205 ~ Show draft separation Eor attic areas IA( ~~o:x::::/:e::;:~i::· :;; :::~/~~:ween /--· dropped ceilings and floor above in excess of 1,000 sq.ft. Sec. 2517 l~". Specify ply,.,ood grade and panel indenti- / hcation index. Table 25-J • tar:' When roof pitch is less than 3:12, design / ridge as a beam. Sec. 2518 (h) ~od shear watts shall not be used to resist horizontal forces contributed by masonry in buildings over one story in eight. Sec. 2516(b) /show access to the attic o r under floor furnace to be minimum 30 inches by 30 inches. Sec. 708 • 709 GMC Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide. Sec 708 UMC ~,/ Show pernianent electrical outlet and yv· lighting fixture controlled by a switch for the attic furnace. Sec. 708 UMC 21'1 Show details to comply with Section ·709 7-· for furnace Linder the floor, Section 70° for attic fL1rnace, or Section 710 for roof or outside furnace. Note on plan, gas vents and non-combustible piping passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC Sec. 1706(al6 Gyps11111 lath and plaster, gyps11111 sheathing oard and gypsum wallboard shall not be used in vertical diaphragms to resist K. ELECTRICAL (National Electrical Code) forces imposed by masonry or concrete All wiring shall comply with the National Electrical A onstruction. Table 47-I ~e. _ -- ! cripple wall studs are less than 14", 22 ........ Not-; on-~-~lan the amperage of electri~~l raming shall be solid bloclung. Sec.2518(g)6 service v ,t. ,~~ '\u..., c:...:, . .,,_'\ ~, n«.vidL\e_ y< · f • ~ > ~vv,t-• . Cri pple wall studs exceeding_4 eet in 22 I! the electrical installation is more.~n,Q height shall be 3 inch by 4 inch or 2 _ ~han 200 amperes, show panel location inches by 6 inches when supporting 2 stories. and provide a single line diagram and Sec. 2S18(g)6 load calculations including: ? a. Wiring method employed. Show ply,.,ood sheathing over exposed eaves, or other weather exposed areas, is exterior grade. Sec. 2S17(g) 3 Show a weep screed at the foundation plate line on all exterior stud walls to be stuccoed. Sec. 4706(el '~ Provide an approved waterproof building /. /,. paper Linder wood siding. Sec. 1701Ca) Specify an approved flashing for exterior openings and parapet walls. Sec. 3208 l}'. Show corridor width to be minimum 36". / Sec. 3304(b) ~ 1rl. Specify truss layout for 30" x 30" attic / • access. 19~ Ridges, hips, and valleys shall be a·t -:7· least one size larger than sL1pported rafters. Sec. 2Sl8(h) J 199. J. Provide metal s~raps across ridge beam and rafters. MECHANICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uniform j\H'rlCal Code. Show the i location and ty of all heating an cooling applianc s or systems. . Show source o! combustion air for furnace will comply with Chaper 6, U.M.C. e, • I SH i.-f'WJ=ltM -s.lul l be • heating facilities capable of maintain- ing a room temperature of 70° F. at 3 feet above the floor in all ·habitable rooms. Show basis !or compliance. UBC- b. Sizes of all conductors, switches, circuit breakers, !uses, and conduits. Approximate length of service feeders . Provide plot plan showing services, c. d. e. all panel locations, circuit arrangement and load distribution on panel busses. Provide typical panel schedule(s). Dwellings require minimum 100 amp service. Show location of all electrical receptacles. Electrical receptacle locations and/or spacing is not adequate in P At least one race cle shall be installed outdoors,,"fnbasements nd attached garages, other thanTa~uc ets. Ar~. 210-25(b) 22::v.' Show minimum dwelling lighting (NEC 7 • Art. 210-26(a) and GFI'S in garage, baths and outdoors. NEC Art. 210-8(al . _ _.._~ Note "UFER" ground to be provided (~IECl . Art. 250-8~}"\4<.....u ~ R..u>ce, ~ PLUMBING (Uniform Plumbing Code) All plumbing shall comply with the Uniform fo.mbing Code . . Show wat{r heater ,iize, type and / location on plans.~ 'S:>,;,c.s, 5:....,, >'-,;~ ~ct.Vt ~j~ • 237. Show method of providing combust 011 a~ to !uel burning water heater. Sec. 1307 238. Sec. 1211~_"'7_ ..--.. __ ,r ~Show minimum JO" deep unobstructed working space in !ront of furnace. Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom. Sec. 1309 ,ft/ Note on plans.clearances to be per manL1fac-r:r· turers listing. Sec. 704 UMC . Furnace shall not be installed under any ( ~ • stairway. Sec. 704 UMC If ,., ~ • ~ Furnace shall not be installed in any ~,,11{ 8 / • bedroom, bathroom, closet, or in confined {I'<.,;.) 243 space wi:~ access only through such room, ·__::? unless speci!ied as direct vent appliance, ,/ enclosed !urnace or electric heatin9 appliance. ,A' sec~~ 0 ~0, --.._r ~ • 240. Show ICSO approvalt'\for prefab fireplace and provide approved installatio~-i~;;;uctio~ c:.:o site. _ _ ___ ,... ____) Provide adequate barrier to protect water heater from vehicle damage. Sec. 1310 Show T and P valve on water heater and show route of discharge line to exterior Sec. 1007(e) Provide dryer vent to outside. Sec. 1903 UMC Note on the plan that hose bibbs and lawn sprinkler systems shall have approved backflow pr evention devices. Sec. 1003 Shower 3tall shall accomodate a J0"circle and have a minimum floor area of 900 sq.in. UPC 909(dl OISE I~SULATION (DUPLEXES) how details of duplex common (party) walls nd floor/ceiling assemblies to achieve a 5ound Transmission Cl ass (STC ) rating /outdoor pools with Eossil Euel heaters require pool covers as wel l as other ene rgy saving devices such as time c locks, etc. T20-l406 in walls of· SO decibles and an Impact o . MISCELLAtraOUS Insulation Class (IICl rating on floor/ ~ A eiling of SO decibles. Title 25 yil. Show a minimum 2• air space and flashing between planter and building walls. how how penet:ation of assemblies for . Sec. 2Sl7(e ) piping, electrical devices, recessed cabinets, / bathtubs, soffits, or heating ventilating, 3_%'. Specify material to be used under the or exhaust ducts shall be sealed, lined, ~ shower tile. Sec. l707(a) or insulated to maintain required sound 3 Specify lath and plaster to comply with /- transmission rating. Titre 25 ," ) Chapter 47, UBC. Prov1d• insulation in walls and ceiling _,><f4. Two 3/4" copper pipes must be installed to ach1eve STC of 50 between garage and from water heater location to convenient living area if garage ~-t~71ot-c:ontrolled -✓ location of future solar panels (City Ord.) (l\-<2'\-\~hY'IC\ Cl.le\\<., ,10, 3 • Provide s l eeves (roof jacks) in roof for ENERGY CONSERVATION \y'\<:,~ .... (-\-~--0 ,· E! ~ <..'Lt-'".,S,b \~, two future 3/4" copper pipes to cc..,nvenient location of fut~re solar panels (City Ord ) by resident Title 25. ( n; All additions to existing residential ~Q..v,. ~,c~e. • bu1ldi ngs must comply with Title 24 ~•-~ \ [1ft Note that solar water piping is to be insulated energy regulations. Additions exceeding' ' "-' in areas that are not heated or cooled. Jo, of the exist1ng building requires the >oe (City Ord. l exist1ng and addition to have R-19 cell.1.nq "'':,.'-~fl,\\.;;g., J07 -insulation if the ex1sting ceiling area ~ ''-See attachment for roofing requirements. ,, is accessible for insulation installation r;;.,.;,--..!.,' •~. ~ _ r 1._.,.,, ·"" ~ T",c rv (T20-l 40l(cl . ~ h)O_. \0 2>G v ::n,;"l::, -\o ,Z, \i•ro\ 1 ~ • • Specify the insulation R values for walls, 5 Ho v .... o lo(£ ...... a.. l~i (')It tt-x2 Y.:l,.s,c>...½1QuJ-, roof and ceiling. (R-ll for walls: R-19 ( \(<C>l2 O'Gw( O 1~, 1 f 0<->S., r2,.-,.;)_J S\,-i c .....J ~ for ce1lings, or provide details and analysis \ ) for alternate design. T20-l 403 Table A, 2B. ~"'1.~\)0vt,1<e u.,; 1-H, '(2.~c1...,, \2~~+ Specify the gross floor area or heated l_' . 1~ .~ g ·1 11. ,/\ v f\ J ' ~ • portions of the dwelling, and th• area v-''1, • \ 1 V~ <..xi <J• t," ~( <l~C:: ~ 1 Yl o/. ....u, ./ of glazed openings on the plan. (T20-l430l / Provide an analysis justifying increasing ---'\..___ ------_ __,- the single glazed area beyond 161 of the gross floor area. Show method to reduce heat loss to that which would occur with basic glazing. (T20-l402,def.) Provide energy analysis to show that the bonnet capacity of the gas central furnace does not exceed the building design heat loss by more than 301. (Exceptions: 48,000 BTU Hr. output furnace. See also California Efficiency Adjustment.) T24-l404 Sote on plan that all tranverse ducts, plenums, and fitting joints of HVAC system shall be sealed with pressure sensitive tape or mastic to prevent air loss. T20-l404 Sote on plan that insulation of ducts shall conform to UMC Section 1005. (T20-l404) Sote on plan that all doors and windows to :he exterior or to unconditioned areas shall be fully weather striped per ANSI Standard. (T20-l403). Note on plan that back draft dampers are required on all fan systems exhausting air from the building. T20-l403 Electrical res1stance space heating shall not be used•unless: a . 601 of heating/cooling is supplied by a nondepletable source. b. supplements a heat pump system. c. less than 10\ of total heating system. d. life cycle cost analysis justifies. T20-1404 Note on plan that all heating and cooling equipment efficiencies shall conform to Title 20-Chapter 2, Subchapter 4, Article 4. ,-4 !75\ for forced air furnaces ). ~ Sote on plan that no natural gas, c entral heating p lant ma y be installed without an tntermittent tgnition Device . T20-l 405 Electric resistance water heating is not permitted unless ver~ied as cost effective oy a life cycle cost analys.1.s. T20-l406 The plans were reviewed baaed on the information shown on the plans. If the plans are in error, or changed during construction, th• permittee shall contact the Building Department for review and prior approval before proceeding with the work: □ □ Building plans are substantially correct and complete. By: ________________ _ Date: __________________ _ Building p lans would be substantially correct and complete if minor corrections are made at counter. By: _________________ _ @Date: uilding plans require major corrections and -7P omplete plan recheck, by plan check _.-,-f engineer, is required. • By: r'-A/v\ G-d <;, ½ >CL1/J Data: __ ...;;;·-3-'¥""';'-3""-+}S"'-'''-3::__ ___ _ rf you have any questions regarding t his plan check, p l ease c a 11 ~ c> ,, a( {o\(t) 5Jo0 \ ¼ P.> . < } We vould also be pleased to meet with you, at no charge, if additional assistance is needed . .. Date I l~/?-o/s> 3 Jurisdiction{;~.:5.t:P70 Prep~by, VALUATION AND PLAN CHECK FEE □ Bldg. Dept. □ Esgil PLAN CHECK NO. 83-88 BUILDING ADDRESS /? S-6-.?LJLE c:;,urz,-j- APPLICANT/CONTACT L<jlVV fJ;f1U PHONE NO. Lf.:JJ ~//0 BUILDING OCCUPANCY /? -3 · 8i2D-DESIGNER PHONE /t TYPE OF CONSTRUCTION V--A.I CONTRACTOR PHO-NE _____ _ BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER /,!jg&~;;'-5/0 ¢.J ~ /4 oo ~--6/:J.{) ' L-11.11 I) Cj I 4-9 (p 9 l/7~ '70 3/2- I I I 'Veck-~ 5(?1 f?r; 7 :z.;, I~ 7 ~--V-5"4-7 V /-JL--r. -h (x-fc,,. c.-t.4 1'1/{7 SJo ~ eBr c:L ::,-a - V r Res . Baths (over 3) @ 2 ,200 Res . Pirepl aces ( 0 'fr @ 1,760 Air Conditionin~ Commercial (<l 2.RO Residential (<l 2 .40 Res. or Comm. Fire Snrinklers @ 1.50 Total Value 19f19 r l) M Ml NI S:...: ---------------------------- 8/4/82 I NTERDEE8RJ11llil AL INFORMATION SHEET lECEIVED . • BfilLD I NG DEPARTMENT DATEM P1R 1 1 1983 BUILDING ADDRESS: /j>'..s-~ £~ CITY OF CARLSBAD: A. P. N: 2. 1 ~ -~ --t -JJ c. T: Bulldln11. Department --·-------~~...._ .. ----___.~-~ £-lL-Ll.:f..:k.iilli * * * * * * * * ******ii*** ,~ * * t * * * * * * * * * * * * * * * * * * * t * * * * ·k]i •• :ls.L'Ll.:£-.~ * o: * * * ,~ :s * PL8NNING DEPARTMENT ZONE: SCHOOL FEES: SAN DIEGUITO SAN MARCOS -------------- ENCINITAS CARLSBAD ------ UNITS REQ'D: PROVIDED: ----------------------% COVERAGE ALLOWED: PROVIDED: -----½--lie-➔.::::::-..::::,__ __ _ PARKING SPACES REQ'D: PROVIDED: -----~--i------ B U IL DING HEIGIIT REQ'D: PROVIDED: --------- FRONT SETBACK REAR SETBACK a ALLOWED : ,b J PROVIDED-:~~==~\==\=~=-- INTRUSIONS: \] RE -DEVELOPt,IENT APPROVAL REQ' D: -----ff-+-lf.--+--- L ANDS CAPE & IRRIGATION PLAN COM~!ENTS: -~<-=::...:..:;:::::.c.__ ____ =--=--~----,1r, ENGINEER I N.G.JJ_ ~~· , -:J.::,. 7 - R.O.W: ______ IMPROVEMENTS: PUBLIC FACILITIES FEE: SEWER CONNECTION: DRIVEWAY LOCATION(S): ---------------·--- GRADING PERMIT: -------------------------• EASEMENTS: DRAINAGE: ----------------------- LEGAL DESCRIPTION : ------------------------- • ADD TT ION/\L CO~IMENTS: *ClIECK If EN OK TO ISSUE: DA1 I:: ---JSD.,~ ----...... -. ------------------------ INSPf: rr · R · 'D. ON FINAL: TE· '!~~~~~ WI: ____ OK TO FINAL: * IF TIIIS ITEM JS NOT CIIECKED, lHJILDING DEPAllHIENT WILL M.'\KE P,JN/\L 1NSrECTlON. --II [I] PACIFIC SOILS ENGINEERING, INC. 17909 FITCH, IRVINE, CA 92714 TELEPHONE: (714) 557-9450 NOTICE OF FOOTING EXCAVATION INSPECTION JOB LOCATION: _I_Z_5_5 __ + ✓-~---~----------- ~rad? Cit 7 WORK ORDER NO.: __,_J_O_D_.:L.....__.3__,,(p.-a._.,_A _____________ _ ~ CONTRACTOR: w~ J)OYL[Y'-.4- OWNER'S ADDRESS: ~ ~ DATE FOOTINGSINSPECTEO ~ 2019g 3 The undersigned hos inspected the looting and.for caisson excavations listed above on the referenced property and some were excavated in accordance with our recommendations in the preliminary foundati on repor and the Building Code of th