Loading...
HomeMy WebLinkAbout1030 TURNSTONE RD; ; CB971937; PermitB U I L D I N G P E R M I T 08/15/97 12:00 Permit No: CB971937 Project No: A9702463 Development No: Page 1 of 1 Job Address: 1030 TURNSTONE RD Suite: Permit Type: RETAINING WALL 8129 08/15/97 0001 01 02 Parcel No: 211-091-20-00 Lot#: C-PRMT 380-00 Valuation: 43,420 Construction Type: NEW ISSUED 07/17/97 08/15/97 JM Occupancy Group: Reference#: Status: Description: RETAIN WALLS 1537 SF,LOTS 39, : 43,46,40,21,38 Appl/Ownr : DICK MILLER, INC 930 BOARDWALK SUITE G SAN MARCOS, CA 92069 *** Fees Required *** *** Fees: Adjustments: Applied: Apr/Issue : Entered By: 760 471-6842 Fees Collected & Credits Total Credits: Total Fees: 624.00 .00 624.00 Total Payments: .00 244.00 380.00 Balance Due: *** Fee description Building Permit Plan Check Units Fee/Unit Ext fee Data Strong Motion Fee * BUILDING TOTAL CITY OF CARLSBAD 2075 Las Palrnas Dr., Carlsbad, CA 92009 (619) 438-1161 376.00 244 .00 4.00 624.00 PERMtT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad CA 92009 (760) 438-1161 1. PROJEC,J:..lNFORMA TION \0 u ~u, Address (include Bldg/Suite #) legal Description Assessor's Parcel # 5, CONTRACTOR • COMPANY NAME #of Stories FOR OFFICE USE ON~ PLAN CHECK NO. t 7 (73 7 EST. VAL. _Lf..::...-=-3_fc......::2:;__/(}_,....,....,----=-- Plan Ck. Deposit ---,---4--" ........ i-.a"""-'1ae- Validated By _ ___.,l-+JC::!'+.:--:::------ Date ____ __.,+.L-J'+--+----- Phase No. Total # of units Proposed Use # of Bedrooms # of Bathrooms (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's license law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged ; 1~G8Vu Name ~ State license # 3 2.,.0 license Class \ ~ City Business license # ~ "Y(/ Designer Name Address City State/Zip Telephone State license # _________ _ 6. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificat e of consent to self-insure for workers' compensation as provided by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. gf I have and will maintain workers' compensation, as required by Section 3700 of the labor Code, for the performance of the work for whic this permit is issued. My worker's compensati~urance carrier and policy number are: n Insurance Company Z,e, O t::Th Policy No.____________ Expiration Date __ \_l....__'"'\-+--- (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100) OR LESS) O CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage la unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest end attorney's fees. SIGNATURE·----------------------,---------DATE _________ _ 7. OWNER-BUILDER DECLARATION ·--~--- 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number):. ______________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address / phone number / type of work):. ________________________________________________________ _ PROPERTY OWNER SIGNATURE _______________________ _ DATE __________ _ COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 26605, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ______________ _ LENDER'S ADDRESS. ________________________ _ 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for Inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void If the building or work authorized by such permit • not commenced within 365 days from the date of such permit or if the building or work euthor1· ed by 1uch permit is suspended or abandoned at any time afte t w~k is co~ryenced f a period of. 1 80 days (Section 106.4.4 Uniform Building Code). q APPLICANT'S SIGNATURE .L-2::.~Ci..A.>V~~=:__-.,,,,.~~~.c.::::;~-----------DATE -, 1 7 l ELlOW: Applicant PINK: Finance Inspection List Permit#: CB971937 Date Inspection Item 9/16/97 66 Grout 9/9/97 66 Grout 9/4/97 61 Footing Thursday, April 01, 1999 Type: RETAIN ____ ln_spector Act PY AP PY AP PY AP RETAIN WALLS 1537 SF,LOTS 39, 43,46,40,21,38 Comments Page 1 of 1 >-.D :.;; iS Ql ,::; (.) C .!!! Q. .!! .. C >-D "' .. iS .. ,::; (.) C .. a: ✓o .!! .. C >-D ~ i5 .. ,::; (.) C .. a: □ PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB "i 7-/o/1..J 7 Address /0 3 0 ~I/~ ~ Planner Gt:e.g-=Fhihef: {l _ ~hone (619) 438-1161, extension 4328 APN: --------------------------------Type of Project and Use: _______________________ _ Zone: ______ Facilities Management Zone: _~ __ D ___________ _ CFO (in/out) # Circle One (If property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department.) Legend [gj Item Complete (LJ Item Incomplete -Needs your action Environmental Review Required : YES NO TYPE ---- DATE OF COMPLETION: ______ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required : YES NO TYPE APPROVAL/RESO. NO. _____ DATE ___ _ PROJECT NO. _______ _ OTHER RELATED CASES: ___________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO Carlsbad Permit Authority or CA Coastal Commission Authority? YES __ NO If California Coastal Commission Authority: Contact them at -3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8-36 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). - 2) Complete Coastal Permit Determination Log as needed. pi□□ □ i□ □ £□ □ □ □ □ □□□ □□□ lnclusionary Housing Fee required: YES NO (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Date Entry Completed? YES __ NO Site Plan: 1 . Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. Zoning: 1 . Setbacks: Front: Required Shown Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown 2. Accessory Structure Setbacks: Front: Required Shown Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown 3 . Lot Coverage: Required Shown 4 . Height: Required Shown 5 . Parking: Spaces Required ------Shown ------ Guest Spaces Required ------Shown ------ Additional Comments ________________________ _ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER ------ EsGil Corporation P rofusiona[ Pfan. !l(_t.viwJ 'Enginurs DATE: August 7, 1997 JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1937 PROJECT ADDRESS: 1030 Turnstone Rd. PROJECT NAME: Retaining Wall SET: II ~ANT ~ □ PLAN REVIEWER □ FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person □ REMARKS: By: Kurt Culver Enclosures: Esgil Corporation 0 GA □ CM □ EJ 0 PC log trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (619) 560-1468 ♦ Fax (619) 560-1576 EsGil Corporation Professional Pfan. 'l(eview 'Enginurs DATE: July 29, 1997 JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1937 PROJECT ADDRESS: 1030 Turnstone Rd. PROJECT NAME: Retaining Wall SET: I □ APPLICANT ■ JURIS. □ PLAN REVIEWER □ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Dick Miller 930 Boardwalk, Suite G San Marcos 92069 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dick Miller Date contacted: 7/29/97 (by: kc) Mail Telephone Fax In Person Telephone#: 471-6842 Fax#: ~ REMARKS: As discussed with Dick Miller, Esgil Corporation is awaiting the soils report for this site. By: 1 Kurt Culver Esgil Corporation □ GA □ CM □ EJ □ PC 7/21/97 Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (619) 560-1468 ♦ Fax (619) 560-1576 Carlsbad 97-1937 July 29, 1997 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1937 PREPARED BY: Kurt Culver DATE: July 29, 1997 BUILDING ADDRESS: 1030 Turnstone Rd. BUILDING OCCUPANCY: Ret. Wall TYPE OF CONSTRUCTION: Mas. BUILDING PORTION BUILDING AREA VALUATION VALUE (ft. 2) MULTIPLIER ($) Ret. Wall 1537 43,420 Air Conditionina Fire Sorinklers TOTAL VALUE 43,420 ~ 1991 USC Building Permit Fee D Bldg. Permit Fee by ordinance:$ 375.50 ~ 1991 USC Plan Check Fee D Plan Check Fee by ordinance: $ 244.08 Type of Review: D Complete Review D Structural Only D Hourly D Repetitive Fee Applicable D Other: Esgil Plan Review Fee: $ 195.26 Comments: Sheet 1 of 1 macvalue.doc 5196 City of Carlsbad ■ #i#i· 11,i§§ I I ■I• I •14 ·El 4 I, ,t§ ,i I BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER: CB qz , / Cf 5 7 BU I LOI NG ADDRESS: ~ID~? o=-----_..---.,_I _;__c)r.!....!/\~S--k>_____:.l\-=::::e_;..___J..R..;.::J__:._ ..., PROJECT DESCRIPTION: _R_e_t_a_in_in....,.g_W_a_l_l _____ _ ASSESSOR'S PARCEL NUMBER: j)t...>G 3 lf~,7A ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to ply with instructions in this report can uspens f permit to build. By: ..___--... (__ ~ Date: ~/b /t 7 ATTACHMENTS D Right-of-Way Permit Application DENIAL Please see the attached report of deficiencies marked with D. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: By: By: Date: -------- ________ Date: ________ Date: ENGINEERING DEPT. CONTACT PERSON NAME: DAVID RICK City of Carlsbad ADDRESS: 2075 Las Palmas Drive Cartsbad,CA 92009 PHONE: (619) 438-1161, ext. 4324 G:ILIBRARYIENOIWORDIOOCSICH<LST\RotaiNng Wal Bulling -Clchl fom, OR.doc Ro,,, ll/22/INI 2075 L as P a lmas Dr.• Carls b a d , C A 9 2009-157 6 • (619) 438-1161 • FAX (61 9) 4 38 -089 4 0 0 0 0 0 0 1. BUILDING PLANCHECK CHECKLIST RETAINING WALLS Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow B. Existing & Proposed Structures (dimensioned from street) C. Property Lines D. Easements E. Retaining Wall (location and height) 2. Show on site plan: A. Drainage Patterns B. Existing & Proposed Slopes C. Existing Topography 3. Include on title sheet: A. Site Address B. Assessor's Parcel Number C. Legal Description D. Grading Quantities Cut___ Fill ___ Import/Export __ _ (Grading Permit and Haul Route Permit may be required) 4. Project does not comply with the following Engineering Conditions of approval for Project No. _________________ _ Conditions were complied with by: _______ Date: ____ _ MISCELLANEOUS PERMITS 5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent tot he public Right-of-Way. A separate Right-of-Way issued by the Engineering Department is required for the following: Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time of resubmittal. Page 1 G:\LIBRARY\ENG\WORDIOOCS\CHKLSl\Rotairong Wal Bulcing Plonchod< Cklol Form OR.doc Rrv. 8l22J'Ge