Loading...
HomeMy WebLinkAbout1027 TURNSTONE RD; ; CBR2017-1255; Permit(city of Carlsbad Residential Permit Print Date: 01/31/2019 Permit No: CBR2017-1255 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1027 Turnstone Rd BLDG-Residential 2110910600 $11,627.50 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Alteration Status: Applied: Issued: Permit Fina led: Inspector: Final Inspection: Description: SHAW: 250 SF REMODEL TO REMOVE FIREPLACE & LOAD BEARING WALL// REPLACE WITH STEEL BEAM Applicant: BROOKS A WORTHING Po Box 1041 Carlsbad, CA 92018-1041 760-729-3965 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: TRUST SHAW FAMILY TRUST 12-19-02 1027 Turnstone Rd CARLSBAD, CA 92011 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $269.10 Total Payments To Date: $269.10 Contractor: BA WORTHING INC 640 Grand Ave, G Carlsbad, CA 92008-2365 760-729-3965 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Closed -Finaled 06/12/2017 04/26/2018 AKrog 1/31/2019 10:23:20AM $0.00 $132.70 $92.89 $41.00 $1.00 $1.51 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov • THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING 0 ENGINEERING □BUILDING □FIRE □HEALTH C cityof Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov Plan Check No rl--J 2.15 Est. Value - Plan Ck. Deposit www.carlsbadca.gov Date lo-\~-7 SWPPP JOB ADDRESS SUITEt/SPACEt/UNIT# APN 02. CT/PROJE T # # BEDROOMS # BATHR TENANT BUSINESS NAME CONSTR. TYPE .GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) ~ (.,~¼c,-e..J 2S>o ~ ~4= EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) FIREPLACE YES[]# FIRE SPRINKLERS YES0 N00 APPLICANT NAME Primary Contact ADDRESS CITY ADDRESS CITY PHONE -, EMAIL ADDRESS I ()-z.-, Tu(' N~N le Rd. STAT~ ZIP FAX CONTRACTOR BUS. NAME (Sec. 7031.5 Business and Professions Code: Arry City or County which requires a permit to construct. alter, improve, demolish or repair any structure, prior to its Issuance. also requires the applicant for such permit to file a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or Chat he Is exempt therefrom, and the basis ror the alleged exemption. Any violation or Section 7031.5 bY any applicant ror a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: I hereby affirm under penalty of pefjUI}' one of the following declarallons: D I have and wlll maintain a certificate of consent to self-Insure for workers' compensallon as provided by Section 3700 of the Labor Code, for lhe performance of the work for which this permit Is Issued. □ I have and will maintain workers' compensation, as reQUited by Section 3700 of the labor Code. for the performance of the work for which this permit is issued. My workers' compensa! imr,rance carrier and policy number are: Insurance Co._J~w~~2--I:l:,1~~~------Policy No. :BAw C @m '08 Cf Expiration Date_,, .J..cl--'--1 .,..[..J~' B------ ~se<:lion need not be completed if lhe rmit Is for one hundred dollars ($100) or less. LJ Certlncate of Exemption: I certify that in the performance of the work for which this permit Is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages ovided n Section 06 of the L code, interest and attorney's fees. _2$ CONTRACTOR SIGNATURE □AGENT DATE I hereby affirm that I am exempt from Contractor's License Law /0< the following reason· □ □ □ I, as owner of the property or my employees with wages as their sole compens License Law does not apply to an owner of property who builds or improves sale. If, however, the building or improvement is sold within one year of comple and the structure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's such work himself or through his own employees, provided that such Improvements are not intended or offered for r will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractois to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or imp<0ves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials fOf construction of the proposed property improvement. O Yes O No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone/ contractors· license number): 4. I plan to provide portions of the mrk, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone f contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone / type of work): _2$ PROPERTY OWNER SIGNATURE □AGENT DATE .... Is the applicant or future building occupant required lo submit a business plan, acutely hazardous materials regislralion form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No Is the applicant or future building occupant required to obtain a pennit from the air pollution control district or air quality management district? D Yes D No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify thatl have read the application and state that the above lnfonnation Is conectand that the information on the plans Is accurate. I agree to comply with all City ordinances and State law.; relating to building construction. I hereby authorize represenlalive of the City of Carlsbad to enter upoo the above mentioned property i:Jr inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSMD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pemin is requred for excavations over 5'0' deep and demolition or coostruction of structures over 3 stories i1 height. EXPIRATION: Every permit issued by the Building Official under the provisons of this Code shall expire by Imitation and become null and void ~ the building or v.ork authorized by such permit is not commenced 1Mthin 180days from the date of such permit or if the build" or\\llfk au riled by su pemiit is us nded or abandoned at any time after themli< is commenced for a period of 100days (Seeton 100.4.4 Unibrm Building Coce). ~APPLICANT'S SIGNATURE DATE (p I \'"'2,.., I STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPANCY {Commercial Projects OnlyJ Fax (760) 602-8560, Email buildinq@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. I CO#: (Office Use Only), CONTACT NAME OCCUPANT NAME AODRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE I FAX EMAIL OCCUPANT'S BUS. UC. No. DELIVERY OPTIONS D PICK UP: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o ASSOCIATED CB# D MAIL TO: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o NO CHANGE IN USE/ NO CONSTRUCTION □ MAIL/ FAX TO OTHER: o CHANGE OF USE / NO CONSTRUCTION A$ APPLICANT'S SIGNATURE DATE PERMIT INSPECTION HISTORY REPORT (CBR2017-1255) Permit Type: BLDG-Residential Application Date: 06/12/2017 Owner: TRUST SHAW FAMILY TRUST 12-19-02 Work Class: Alteration Issue Date: 04/26/2018 Subdivision: CARLSBAD TCT#94-11 Status: Closed • Finaled Expiration Date: 02/11/2019 Address: 1027 Turnstone Rd Carlsbad, CA 92011-1219 IVR Number: 4264 Scheduled Actual Inspection No. Inspection Status Primary Inspector Re inspection Complete Date Start Date Inspection Type 06/26/2018 06/26/2018 BLDG-66 Grout 062132-2018 Passed Andy Krogh Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Footing for strong wall. Other footings and Yes steel beam deleted by engineer with letter as removed wall was a non load bearing wall 07/31/2018 07/31/2018 BLDG-23 065497 -2018 Passed Andy Krogh Complete Gas/Test/Repairs BLDG-84 Rough 065622-2018 Passed Andy Krogh Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 08/15/2018 08/15/201 8 BLDG-16 Insulation 067010-2018 Passed Andy Krogh Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency With picture Yes BLDG-17 Interior 067154-2018 Passed Andy Krogh Complete Lath/Drywall 01/31/2019 01/31/2019 BLDG-Final 082680-2019 Passed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes January 31, 2019 Page 1 of 1 PCSD Engineering Corp 3529 Coastview Court Carlsbad, CA 92010 Ph: 760-207-1885 P12-o.:re.e,,: £\.lbW Re-.s10~ • IOl"'7 TU\?.tJsn>t.\E io. U'c{L~ M0) CA: 12. 0 ·11 Job#: 17•i 6t; • Page: \ of__,. __ _ Date: '-/ltJ/12 .,. .. Engineer: ______ _ RECORD COPY TuE. OtUC:IIJAL uA\.\_. IS >JOT A . S\i~ WAl,L ~ ~ Bl i.UMWAtfO. No F'Oow..tt: IS VNOtL 1'11S l&A\L ~--1~ _OJ-1~'7.,"'.' C.o)jJ,l\1<.tvD 1,,/ S\'loT ?\J.-t~. 1l1ta.Elo~ 3 11-U~ ·wli.u.. .. lS .>-lo}.{ SMiiAn.... ~ ®l ·f>E. 011, rrtcO / _City of Carlsbad JUN 2 6 2018 BUILDING DIVISION PAuL 5. CYlrusTWA./ Pn.omr. ~~121L-- I City of Carlsbad cbR2017-1434 July 10, 2017 «~·, ~ CI T Y OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 RECEIVED APR O 5 201 8 CITY OF CARLSBAD BUl~ffi-bJ?~~PS'krvices Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special Inspection, structural observation and construction material testing. 'roject/Permit: C~,e..z.o I 1-l :2-55 Project Address: to2-1 hJIZ-fu.~ \-oNJE'.. 12..o • A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder □. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print,_) ---'~""--'-.... lo"-'c~:i...,' NCL.:._~;__ ___ .._, .:...· i.:,f-,_,.c..,vl-1 ______ ----'?<........:....r\Aj,'J..>:....>..=----- IFirsl) (MI) • /) MailingAddress· I0:2,,"1 TuCN~e.. I<L1 Cyv[~b.JW Email' ( j n Ct sher£? food ( unf\~ C ~ 11.,,sr1 Phone: I am: ~roperty Owner □Property Owner's Agent of Record □Architect of Record □Engineer of Record State of California Registration NumbeL...·------------Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the state of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspection~°t1e~ on the ~,,frover plans and, as required by the California Building Code. Signature· ()~lJW«-1 re.. · ~N(,N -Date: _4-+-1cf-~-'-+/2........_B..__ ____ _ B. CONTRACTOR'S STATEMENT OF RbSPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor/ builder/ owner-builder. '(__J Contractor's Company Name: Bi\: Wo .f..i ~H I IV61 l 1\l C • Please check If you are Owner-Builder o Name: (Please print) _ __:P.>.:.......:.ll-o=...,,(:J"::-'-k=--~-----------------'~:....;:;,;;,l_o_e..,,--l~c--'-'--l r'-'\.L=-=b,""------ !Forst) (M.11 t;;ij' Mailing Address:_f.Q_~ Q )Q l O '-( I Uvz .. ,Lh ~f\.-..6 CA-'1 Z-0 I B Email: €zklf-,to-,e..,t=4 1 tvLu 1,~ 1./Act<oo , 00""1 Phone: __ 't~"'..:::.o_7--'-L_q.,___3_ci..:.......,::i'-S-- State of California Contractor's License Number: ~ '1 ~ 1 h '-f Expiration Date: 1 I~ I zo z..o • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. ,/1 ?~-- Signature: :sfl~ Date Lf{ ~ /t 0 (_j B-45 Page 1 of 1 Rev. 08/11 EsGil Corporation In <Partnersliip witli qovernment for (]Jui{tfing Safety DATE: 04/ 16/ 18 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-1255 PROJECT ADDRESS: 1027 Turnstone Rd. SET: III □ APPLICANT /°JURIS. □ PLAN REVIEWER □ FILE PROJECT NAME: Remove bearing walls, replace with steel beam ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: BA Worthing Inc. ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Brooks Worthing Telephone #: (760)729-3965 Date contacted: ___., (b~ ) Email: BAWorthinglnc@yahoo.com Mail Telephone Fax ~rson 0 REMARKS: By: Javier Snider (RJM) EsGil Corporation 0 GA O EJ O MB O PC Enclosures: 04/09/18 9320 Chesapeake Drive, Suite 208 ♦ San Diego, Cali fo rnia 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 I Carlsbad CBR2017-1255 03/26/18 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 2. 9. 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Please provide a T24 detailing compliance. For plans submitted for plan check on or after 1 /03/17, provide an energy design detailing compliance with the Mandatory Measures and either the Performance or Prescriptive Methods of • compliance. The Prescriptive design and the latest Performance software programs are available at: The T-24 sheets indicate a failure to comply with energy standards. Please provide energy calculations. http://www.energy.ca.gov/title24/2016standards/index.html -f (LJ)J\Ot-t> To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. I Carlsbad CBR2017-1255 03/26/18 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ryan Murphy at EsGil Corporation. Thank you. EsGil Corporation In <Partnersfiip witfi <Jovernment for (]Jui(aing Safety DATE: 03/26/18 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-1255 PROJECT ADDRESS: 1027 Turnstone Rd. SET: II 0 APPLICANT ~ JURIS. 0 PLAN REVIEWER 0 FILE PROJECT NAME: Remove bearing walls, replace with steel beam D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [Z] The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [Z] The applicant's copy of the check list has been sent to: BA Worthing Inc. D EsGil Corporation staff did not advise the applicant that the plan check has been completed. [Z] EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Brooks Worthing Telephone#: (760)729-3965 Date contacted:3/z.6 \i~ (by~ Email: BAWorthinglnc@yahoo.com ro:, Teleph~ Fax In Person □~ARKS. __.f(<t>tJr Desj:... By: Javier Snider (RJM) EsGil Corporati on 0 GA O EJ O MB O PC Enclosures: 03/19/18 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2017-1255 03/26/18 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 2. 9. 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Please provide a T24 detailing compliance. For plans submitted for plan check on or after 1/03/17, provide an energy design detailing compliance with the Mandatory Measures and either the Performance or Prescriptive Methods of compliance. The Prescriptive design and the latest Performance software programs are available at: The T-24 sheets indicate a failure to comply with energy standards. Please provide energy calculations. http://www.energy.ca.gov/tit1e24/2016standards/index.html To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Carlsbad CBR2017-1255 03/26/18 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ryan Murphy at EsGil Corporation. Thank you. i EsGil Corporation In <Partnersfiip witfi qovernment for (]Jui(aing Safety DATE: 06/20/2017 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-1255 PROJECT ADDRESS : 1027 Turnstone Rd. SET: I □ APPLICANT ~JURIS. □ PLAN REVIEWER □ FILE PROJECT NAME: Remove bearing walls, replace with steel beam D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8J The applicant's copy of the check list has been sent to: BA Worthing Inc. D EsGil Corporation staff did not advise the applicant that the plan check has been completed . [8J EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Brooks Worthing Telephone#: (760)729-3965 Date contacted: ilz.• In (by~) Email: BAWorthinglnc@yahoo.com ~elephone Fax In Person 0 REMARKS: By: Ryan Murphy EsGil Corporation 0 GA O EJ O MB O PC Enclosures: 06/13/2017 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 . Carlsbad CBR2017-1255 06/20/2017 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: CBR2017-1255 JURISDICTION: Carlsbad PROJECT ADDRESS: 1027 Turnstone Rd. FLOOR AREA: unchanged unchanged REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 06/12/2017 DATE INITIAL PLAN REVIEW COMPLETED: 06/20/2017 FOREWORD (PLEASE READ): STORIES: unchanged HEIGHT: unchanged DATE PLANS RECEIVED BY ESGIL CORPORATION: 06/13/2017 PLAN REVIEWER: Ryan Murphy This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled . This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2017-1255 06/20/2017 • PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The current set is missing designer signatures. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation , along with structural calculations. (California Business and Professions Code). Please have the engineer of record stamp and sign sheet 4. 4. Please update your code references. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2016 California Residential Code, which adopts the 2015 IRC, 2015 UMC, 2015 UPC and the 2014 NEC. Section R106.1. 5. Please update note 1, under Green Building Standards Notes, on sheet 1 to 65% of construction waste is to be recycled. 6. On Sheet 2, please revise 2nd floor plan title to Existing 2nd Floor Plan. 7. On sheet 4, please label framing and foundation layout appropriately. (Both labeled foundation layout on this set). 8. Please remove the note on the title sheet about registering the energy compliance forms, as this is only required when a HERS inspection is necessary. However, a T24 energy analysis is required due to the new French doors on the living room/family room exterior wall. . . • .. Carlsbad CBR2017-1255 06/20/2017 9. Please provide a T24 detailing compliance. For plans submitted for plan check on or after 1/03/17, provide an energy design detailing compliance with the Mandatory Measures and either the Performance or Prescriptive Methods of compliance. The Prescriptive design and the latest Performance software programs are available at: http://www.energy.ca .gov/title24/2016standards/i ndex. htm I 10. Please submit the special inspection agreement form attached to the end of this list. (Expansion anchors in existing footing). • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ryan Murphy at EsGil Corporation. Thank you. . Carlsbad CBR2017-1255 06/20/2017 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Ryan Murphy BUILDING ADDRESS: 1027 Turnstone Rd. BUILDING OCCUPANCY: R-3/U BUILDING AREA PORTION ( Sq. Ft.) demo/remodel 250 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Bldg. Permit Fee by Ordinance G Plan Check Fee by Ordinance -a Valuation Multiplier By Ordinance Type of Review: Complete Review D Repetitive Fee ~ Repeats D Other □ Hourly EsGil Fee PLAN CHECK NO.: CBR2017-1255 DATE: 06/20/2017 Reg . VALUE ($) Mod. 11 ,627 11 ,627 $132.331 $86.01 I D Structural Only $74.101 Comments: In addition to the above fee, an additional fee of $43 is due (1/2 hour@ $86/hr.) for the CalGreen review.