Loading...
HomeMy WebLinkAboutCDP 2021-0048; WEINZETTLE-DIETRICH ADU; Administrative Determination~ ct: ~ .., Q) Q) I.. .., en C: 0 "' I.. Q) q Q) ..., I I I I I TO WATER MAIN ..:--------- TO SEWER MAIN -,;--------- ~ WATER M□ER 60' ENGINEERING NOTES 1. OWNER TO OBTAIN CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT-OF-WAY. FAILURE TO DO SO WILL RESULT IN THE ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE THE PROPERTY LINE IS LOCATED. 3. NO CONCENTRATED DRAINAGE FLOWS ARE PERMITTED OVER ADJACENT PROPERTY LINES. 4. WATER IS TO DRAIN AWAY FROM THE STRUCTURES FOR A MINIMUM OF 5 FEET AT 2 PERCENT AND BE CONVEYED TO AN APPROVED DRAINAGE FACILITY. 5. EROSION CONTROL MEASURES (E.G. BONDED FIBER MATRIX, VEGETATIVE COVER, JUTE MATTING) MUST BE IMPLEMENTED WHERE APPLICABLE TO PREVENT SOIL EROSION ON SITE. SEDIMENT CONTROL MEASURES (E.G. SILT FENCING, FIBER ROLLS, DETENTION BASINS) MUST BE IN PLACE TO PREVENT ERODED SOIL FROM LEAVING SITE. MATERIALS MANAGEMENT BMP MUST ALSO BE FOLLOWED TO ENSURE NO CONTACT OF RAINWATER WITH MATERIALS THAT MAY CONTRIBUTE TO WATER QUALITY DEGRADATION DOWNSTREAM (E.G. CONCRETE OR STUCCO WASHOUT AREAS, COVERED STORAGE AREAS FOR HAZARDOUS MATERIALS, PLACEMENT OF PORTABLE TOILETS OVER A PERVIOUS SURFACE). 6. NO DIRECTLY CONNECTED IMPERVIOUS AREAS (DCIA) SHALL BE ALLOWED. DCIA MEANS STORM RUNOFF GENERATED AND CONVEYED VIA IMPERVIOUS AREAS, SUCH AS ROOF, ROOF DRAIN, DRIVEWAY, AND STREET. BMP MEASURES SHALL BE IDENTIFIED ON THE SITE PLAN. MOST COMMON MEASURES ARE DESIGNATED TURF AREAS, WHICH RECEIVE ROOF DRAINS AND RUNOFF FROM IMPERVIOUS AREAS. TURF AND LANDSCAPED AREAS THAT ARE DESIGNATED FOR BMP'S SHALL BE DELINEATED ON PLANS AND NOTE PLACED ON PLANS PROHIBITING MODIFICATION OR REMOVAL OF THE BMP LANDSCAPE AREAS WITHOUT A CITY PERMIT. STORM WATER QUALITY NOTES CONSTRUCTION BMP'S CONCRETE WASHOUT CONTP.ACTOR SI-W.L ESTABLISH AND USE AN ADEQUATELY SIZED CONCREfE WASHOUT AREA TO CONTAIN WASHOUT WASTE ON SITE. IT IS lll.EGAL TO WASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORM WATER CONVEYANCE SYSTEM OR Nff RECEMNG WATER. CONTRACTOR SHALL POST A SIGN DESIGNATING TI,E WASHOUT LOCATION. CONSTRUCTION SITE ACCESS A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS Af.lD INGRESS TO PREVENT TRACKING DIRT OFF SITE. THIS SHALL INCLUDE USING MATERIAL SUCH PS GRAVEL AND/OR CORRUGATED STEEL PANELS/PLATES. CONSTRUCTION VEHICLES A SPECJFlC Nl.f.A AWAY FROM GVTTERS AND STORM DRAIN SHALL BE DESIGNATED FOR CONSTRUCTION VEHICLE PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPA.IRS SI-W..l BE MADE OFF SITE. EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FOR ALL EROSIVE SURFACES. SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INST.AWNG EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER t.fATRIX. NO EXCAVATION AND GRADING ACTMTIES ARE ,ALLOWED DURING WET WEATHER DIVERSION DIKES SHALL BE CONSTRUCTED TO CHANNEL RUNOFF AROUND THE CONSTRUCTION SITE. CONTRACTOR SHALL f1ROTECT CHANNELS AGAINST EROSION USING PERMANENT ANO TEMPORARY EROSION CONTROL MEASURES. REti!OVE EXISTING VEGETATION ONLY WHEN ABSOLUTELY NECESSARY. LARGE PROJECTS SHALL BE CONDUCTED IN PHASES TO AVOID UNNECESSARY REMOVAL OF THE NATURAL GROUND COVER. 00 NOT REMOVE TREES OR SHRUBS UNNECESSARILY; THEY HELP DECR~E EROSION. TEMPORARY VEGETATION MUST BE PLANTED ON SLOPES OR WHERE CONSTRUCTION IS NOT IMMEDIATELY PLANNED FOR EROSION CONTROL PURPOSES. EROSION SHAU BE PREVENTED BY PLANTING FAST-GROWING ANNUAL ANO PERENNIAL GRASSES TO SHIELD AND BIND THE SOIL PL.ANT PERMANENT VEGETATION AS SOON AS POSSIBLE, ONCE EXCAVATION AND GRADING ACTIVITIES ARE COMPLETE. WATER USAGE FOR DUST CONTROL SHALL BE MINIMIZED. ON-SITE CONSTRUCTION MATERIAL STORAGE STORED MATERIALS SHALL BE CONTAINED IN A SECURE PLACE TO PREVENT SEEPAGE AND SPILLAGE. CONTRACTOR SHALL STORE THESE PRODUCTS WHERE THEY WILL STAY DRY OUT OF THE RAIN. CONTRACTOR SHALL PROVIDE SECONDARY CONTAINMENT FOR ALL FUEL STORED ON-SITE. ELIMINATE OR REDUCE POLLUTION OF STORMWATER FROM STOCKPILES KEPT ON-SITE. STOCKPILES t.fAY INCLUDE SOIL, PAVING MATERIAI...S, ASPHAlT, CONCRETE, AGGREGATE BASE, ETC. STOCKPILES SHALL BE LOCATED AWAY FROM CONCENTRATED STORMWATER FLOWS ANO STORMDRAIN INLETS. STOCKPIL£S SHALL BE COVERED OR PROTECTED WITH SOIL STABIUZATICN MEASURES AND PROVIDED WITH A TEMPORARY SEDIMENT BARRIER AROUND THE PERIMETER AT ALL TIMES. TRAJNING CONTRACTORS' EMPLOYEES WHO PERFORM CONSTRUCTION IN THE CITY OF ENCINITAS SHALL BE TRAINED TO BE FAMILIAR 'NITH THE CIT't' OF ENCINITAS STORMWATER POLLUTION CONTROL REQUIREMENTS. THESE BMP NOTES SHALL BE AVAJLABLE TO EVERYONE WORKING ON-SITE. THE PROPERTY OWNER ANO THE PRIME CONTRACTOR MUST INFORM SUBCONTRACTORS ~VT STORMWATER REQUIREMENTS AND THEIR OWN RESPONSIBILITIES. WASTE MANAGEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISPOSING OS ALL WASTF. AND UNUSED CONSTRUCTION MATERIALS. DUMPING OF UNUSED OR WASTE PRODUCTS ON THE GROUND, WHERE WATER CAN CARRY THEM INTO THE CONVEYANCE SYSTEM IS STRICTLY PROHIBITED NO SEEPAGE FROM DUMPS1ERS SHALL BE DISCHARGED INTO STORMWATER. BERMS/DIKES SHALL BE PLACED AROUND DUMPSTERS TO DIVERT THE NATURAL STORM RUNOFF. DUMPSTERS SHALL BE CHECKED FREQUENTLY FOR LEAKS. DUMPSTER LIDS SHALL REMAIN CLOSED AT All TIMES. DUMPSTERS WITHOUT LIDS SHALL BE PLACED WITHIN STRUCTURES WITH IMPERVIOUS ROOFING OR COVERED WITH TARPS IN ORDER 10 AVOID RAIN CONTACT WITH ANY TRASH MATERIAL MANY CONSTRUCTION MATERIALS, INCLUDING SOLVENTS, WATER-BASED PAINTS, VEHICLE FLUIDS. BROKEN ASPHALT AND CONCRETE, WOOD AND CLEARED VEGETATION CAN BE RECYCLED. NON-RECYCLABLE MATERIALS MUST BE TAKEN TO AN APPROPRIATE LANDFILL OR DISPOSED OF PS HAZARDOUS WA.STE. POLLUTANTS SHALL BE KEPT OFF EXPOSED SURFACES, PLACE TRASH CANS AND RECYCLING RECEPTACLES AROUND THE SITE. PORTABLE TOILETS MUST BE IN GOOD WORKING ORDER AND CHECKED FREQUENTLY FOR LEAKS, CONTRACTOR SHALL PROVIDE SECONDARY CONTAJNMENT AND LOCATE PORTABLE TOILETS AWAY FROl.1 STORMDRAIN INLETS ON PERVIOUS SURFACES. ALL CONSTRUCTION DEBRIS SHALL BE KEPT AWAY FROM THE STREET, GVTTER, AND STORMDRAIN, CONTRACTOR MUST ROUTINELY CHECK AND CLEAN UP MATERIAL THAT MAY HAVE TRAVELED AWA.Y FROM CONSTRUCTION SITE. 61' 2642 co ---····------. ~ Exibit No. '-'A e_, __ ;:;:--;-lftBT-:zi·-- ---_._.--=" --• 0 N 89'57' W 245.00' I --------------------N·as-s7--w·245..oo-:---------------------------------------------------------------------------------,-------- ~ 2646 SURFACE WATER SHALL DRAIN AWAY FROM THE BUILDING MIN 6" FALL WITHIN 1st 10 FEET FIRE DEPT NOTES 1. APPROVED ADDRESS NUMBERS AND/OR ADDRESSES SHALL BE PLACED ON ALL NEW AND EXISTING BUILDINGS AND AT APPROPRIATE ADDITIONAL LOCATIONS AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY FRONTING THE PROPERTY FROM EITHER DIRECTION OR APPROACH. S/oJD NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND, AND SHALL MEET THE FOLLOWING MINIMUM STANDARDS AS TO SIZE: 4" HIGH WITH A 3/8" STROKE FOR RESIDENTIAL BUILDINGS 2. GATES -ALL GATES OR OTHER STRUCTURES OR DEv1CES, WHICH COULD OBSTRUCT FIRE ACCESS ROADWAYS OR OTHERWISE HINDER EMRGENCY OPERATIONS, ARE PROHIBITED UNLESS THEY MEET STANDARDS APPROVED BY THE FIRE DEPARTMENT. GATES ACROSS FIRE ACCESS ROADWAYS SHALL BE AUTOMATIC AND EQUIPPED WITH APPROVED EMERGENCY KEY OPERATED SWITCHES OVERRIDING ALL COMMAND FUNCTIONS AND OPENS THE GATE(S). GATES ACCESSING FOUR OR MORE RESIDENCES OR RESIDENTIAL LOTS, OR GATES ACCESSING HAZARDOUS, INSTITlfflONAL, EDUCATIONAL OR ASSEMBLY OCCUPANCY GROUP STRUCTURES, SHALL ALSO BE EQUIPPED WITH APPROVED EMERGENCY TRAFFIC CONTROL ACTIVATING STROBE SENSORS WHICH WILL ACTIVATE THE GATE ON THE APPROACH OF EMERGENCY APPARATUS W1TH A BATTERY BACKUP OR MANUAL MECHANICAL DISCONNECT INCASE OF POWER FAILURE. ALL AUTOMATIC GATER MUST t.1EET FIRE DPARTMENT REQUIREMENTS FOR RAPID, RELIABLE ACCESS. WHERE THIS SECTION REQUIRES AN APPROVED KEY OPERATED SWITCH, IT SHALL BE DUAL KEYED OR DUAL SWITCHES WITH COVERS PROVIDED TO FACILITATE ACCESS BY LAW ENFORCEMENT PERSONNEL. 3. A CLASS "A" ROOF ASSEMBLY SHALL BE INSTALLED 4. HOUSEKEEPING -GOOD HOUSEKEEPING SHALL BE MAINTAINED AT ALL TIMES. ACCUMULATION OF COMBUSTIBLE WASTE MATERIALS IN THE BUILDING SHALL NOT BE ALLOWED NFPA 13D FIRE SPRINKLERS WILL BE INSTALLED FOR THE PROIPOSED ADU ONLY GENERAL NOTES 1. THIS PROJECT SHALL COMPLY WITH THE 2019 CALIFORNIA BUILDING CODE THE 2019 CALIFORNIA MECHANICAL CODE, THE 2019 CALIFORNIA PLUMBING CODE, THE 2019 CALIFORNIA ELECTRICAL CODE, THE 2019 CALIFORNIA ENERGY CODE, THE 2019 CALIFORNIA FIRE CODE, THE 2019 RESIDENTIAL CODE, AND THE 2019 CALIFORNIA GREEN STANDARDS CODE. 2. MINIMUM 65% CONSTRUCTION DEBRIS WILL BE RECYCLED. 3. OWNER TO OBTAIN CONSTRUCTION PERMIT FROM THE ENGINEERING DEPARTMENT AT LEAST 48 HOURS PRIOR TO WORKING IN THE PUBLIC RIGHT-OF-WAY. FAILURE TO DO SO WILL RESULT IN THE ISSUANCE OF A STOP WORK NOTICE AND DOUBLE PERMIT FEES. IT IS THE RESPONSIBILITY OF THE OWNER TO KNOW WHERE THE PROPERTY LINE IS LOCATED. 4. SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL, WHO SHALL REVIEW THEM AND FORWARDTHEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THESE ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUt.lENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL ITEM: 5. ADDRESS NUMBERS SHALL BE CLEARLY VISIBLE FROM THE STREET FRONTING THE STRUCTURE. WHERE STRUCTURES AREA LOCATED OFF A ROADWAY OR LONG DRIVEWAYS, A MONUMENT SHALL BE PLACED AT THE ENTRANCE WHERE THE DRIVEWAY INTERSECTS THE MAIN ROADWAY. PERMANENT ADDRESS NUMBERS SHALL BE DISPLAYED ON THIS MONUMENT. MINIMUM FIVE (5) INCH NUMBERS FOR RESIDENTIAL. ' 0 I LO SITE PLAN SCALE: 1" = 1 O' -0" NET CHANGE IN AVERAGE DAILY TRAFFIC = 0 NET CHANGE IN WATER DEMANDS = 0 NET CHANGE IN SEWER GENERATION = 0 CU YDS CUT = 0 CU YOS FILL = 0 CU YDS OVER EXCAVATE/RECOMPACT = 45 CU YOS IMPORT /EXPORT = 0 HEIGHT OF CUT/FILL = 0 TOTAL CUBIC YARDS OF GRADING = 45 PROPERTY OWNER WEINRICH UNITED REVOCABLE TRUST 330 LA VETA AVE ENCINITAS, CA 92024 619.887.6725 APPLICANT BEN LELAND CONSTRUCTION 270 N EL CAMINO REAL SUITE 297 ENCINITAS, CA 92024 760.436.1506 SCOPE OF WORK G z 0 <J) a:: tt' u_ L,J -, CONSTRUCT 990 SQ FT DETACHED ADU WITH FIRE SPRINKLERS VICINITY MAP BUENA VISTA WAY SITE LAGUNA DRIVE LAGUNA DRIVE ... (/) Cl 0 0 ~ _J L,J Proposed ADU PROJECT NAME COASTAL DEVELOPMENT PERMIT FOR THE WEINZETTLE-DIETRICH RESIDENCE ADU PROJECT DATA ASSESSORS PARCEL NO. : 155 -271 20 SITE ACREAGE : .28 ACRES ( 12,177.5 SQ FT) ZONING : R-3 LAND USE DESIGNATION : R-15 DENSITY : 3.6 DU/ACRE BUILDING COVERAGE PERCENTAGE : 21.94% (35% max) BUILDING COVERAGE AREA : 2,672 SQ FT PARKING : 3 OFF-STREET SPACES SCHOOL DISTRICT : CARLSBAD WATER DISTRICT CARLSBAD MUNICIPAL WATER DISTRICT SEWER DISTRICT : CARLSBAD MUNICIPAL WATER DISTRICT CLIMATE ACTION PLAN COMPLIANCE a. CONSISTENT WITH EXISTING GENERAL PLAN LAND USE AND ZONING -YES i. GHG STUDY REQUIRED -NO b. ENERGY EFFICIENCY REQUIREMENT YES i. ATTIC INSULATION c. PHOTOVOLTAIC REQUIREMENT -YES d. ELECTRIC VEHICLE CHARGING REQUIREMENT -NO e. HOT WATER HEATING REQUIREMENT -YES f. TRAFFIC DEMAND MANAGEMENT REQUIRED -NO LEGAL DESCRIPTION LOTS 7 AND 10, IN BLOCK 1 OF SUNNYSLOPE TRACT, IN THE CITY OF CAALSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 486, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, FEBRUARY 7, 1888. AREA CALCULATIONS LOT AREA : 12,177.5 SQ FT (E) RESIDENCE AREA : 1,027 SQ FT (E) GARAGE AREA : 555 SQ FT PROPOSED ADU LIVING AREA : 990 SQ FT (E) PORCH AREA : 100 SQ FT TOTAL FOOTPRINT AREA : 2,672 SQ FT BUILDING COVERAGE : 21.94% (35% ALLOWABLE) RfCEIVE!D DEC 03 2021 CITY OF CI\F<L.SBAD NO. REVISIONS: BY: 2 3 0::: 0 LL t- z ::J c., z ....J ....J w 3:: 0 >-0::: 0 (/) (/) w (.) (.) <( Q) (J C Q) "C ·-"' Q) c::: .s::: (J ·-I.. ...., Q) ·-C I Q) -...., ...., Q) N C ·-Q) ~ Q) .s::: I- .... 00 0 .., 0 Q) N Q) O') I.. u5 -~ c: E 0 O ~~ a, ca :t: (.) Cl) ~ ..., "C "lit ca "lit .c (0 "' N i: ca (.) SITE PLAN PIAN FILE NUMBERS CDP PIAN CHK PERMIT DATE: 11-19-21 SCALE: 1" = 10'-o" JOB. NO. 210827 SHEET C-1 PLANNING DIVISIOi\l '----------' I I I I I I I ' I !ii :::i, I ~I a.' ~· a.I ' I I I 60' SITE SECTION A SCALE: 111 = 10'-011 I ' ' I ' ' I ' ' l!i ,:::i I ,~ 'L,J ,a. ,~ ' ' I I ' ' ' I ' ' I ' ' I I ' I I I I I ' I I ' ' l!i ,:::i ~. i~ Q.. I 11.&.J a. gl ,a. L,J z :::J -, ~ -,, ' ' I , , I ' ' i II 60.B'!-, 1 _____ .__ __________ .J.._..j_ __ _ ; , 60.8' I , , I ' ' I , , I ' ' I , I SITE SECTION B SCALE: 1" • 10'-0" 61' RECEIVED DECO 3 2021 CITY OF CAf',LSBAD PLANNING DIVISIO~I • NO. REVISIONS: BY: 2 3 >-CD 0 z t;: ~ 0 \.J\ 2 C) - \.j\ -u u--" D 2 ~ \.j\ u--" D a., (J C: a., "C Cl:'.: • - f2 ~ t::: 0::: z => .c: (J Cl ■-Z ... _J +■I _J a., w ■- 3: C 0 I a., ~-0:::: (/) a., (/) N ~ C: u <( ■-a., ~ a., .c: I- "<t- (0 co 00 N O'l O> (0 I I co <C ..i-E (.) r---0 (.) I co ui >, I.{) § C CO•-31: ..__,, .!!! 0 X ~ a.. 0 "C I '+-C C'l ·-(/J "C r---Q) C I.{) "'C 0 O'l >, Ck: ,-E • (/J I :r:: ~ "<I'" 31: 31: r---31: 0 r---a.. ,......_ r--co 01.{) (0 co I") ..__,, .... - 00 0 +,,I 0 (1) N (1) 0, :i.... .., ca en ·- c: E 0 .e (/J ·-I■• -~ ca (1) (.) -, "C~ ~ ca ~ .c (0 (/J N "'i: C'0 (.) SITE SECTIONS PLAN FILE NUMBERS CDP PLAN CHK PERMIT DATE: 11-19-21 SCALE: 1 • = 1 o' -o" JOB. NO. 210827 SHEET C-2 MAX HEIGHT --- IGf-lT PL HOR ½ '" FF FG MAX HEIGHT EIGHT PL MAX HE HT E l'e._ IGH": - .PL HOR ,..:10l :r ro '\' "' FF ---'FG MAX HEIGHT lEIGf-lT PL q q, s-('); -- ,::IN 'f "' L? "' HOR FF FG - HOR FG JI Ill j --- J I II II LJ II II I I _J II " ' J LJ II I I I ' II J I 'ii I II J l 11 I J1 ' u -l J _l JJJ J I _LU J I I J I • ---~--- IT;~ 1. TG ' TG ,/ ,, ' ,/ 1 V " ' -, i ', ' ' I ' ' - WEST EXTERIOR ELEVATION SCALE: 1/4'" -1'-0 .. • TG 1 ) SOUTH EXTERIOR ELEVATION SCALE: 1/4" • 1 '-0" --~ - LI I I II I II II ! 11 I. Ji /--J II U LJ II L J __J_ u I 'I lJ J I J _l I I L _J C _J_jj_ LJ U.J ..L LJ I I II II LIJI LJ I I 11 II l II 1111 II II II II LJ II II II II J II LJ LJ J .J .J J I i I I 11 1111 111 -- _____ J II II LJ ' ~ " I II LJ V I Ill ' ' ,r--COMPOSIT:ON ROOF SHINGLES BY GAF ATING CLJ\SSJ\ FIRER 5 ICC FS FSR-147, OVER 3:J# FFI.T \ -~ PAINTED METAL \ DRIP cDGE. TYP ,_ \____ 2x8 FASCIA, TY P, '· / - UON ON PLANS ------------........_ CEMENT PLAST ER SlotNG OR O l"HER SELECT ED EXTERIOR FINISH 1 ,,.,----CONCRETE SLA 3 AND FOOTINGS SH GRADE v/ / _,/ ,_.,,-----EXISTING & FINI ICC I::~ ESR-1475 / COMPOSITION ROOF SHINGLES BY GAF CLASS A FIRE RAT· NG , OVU{ JO# 1--1::L I -- \_ PAINTED METAL DRIP EDGE, TYP ",....___......_ \_ 2x8 FASCIA, TYP UON ON PLANS ,...______ Cl::Ml:::N I PLASTER SIDING OR OTHER SELECTED EXTERIOR FINISH 1 ___---CONCRETE SLAB AND FOOTINGS -/ _,.,-,-EXISTING & FINISH GRADE J l Ll rfl I I v-COMPOSITION R I 11 LJ lill I LJ J 1111 I 1111 Li 1 11 11 I 1111 LJ 11 II , CLASS A FIRER 1 11 1 u--r ICC ES ESR-147 OOF SHINGLES BY GAF ATING 5 I iJ ,II II II II II II OVER 30# FELT II I I ' I I I I I 11 _[ J I I I 1111 I ii i \" P, \\ PAINTELJ METAL --------,.- L □---□ TG \'-2x8 FASCIA, TY ~ UON ON PLANS ----·--------------------------CEMENT PLAST ~-I OTHER SELECT r--------------A ER SID!NG OR ED EXTERIOR FINISH #1 DRIP EDGE, TYP ------TANKLESS WAT ER HEATER 1! -------~.,----------CONCRETE SLA ---i--,-EXISTING & FINI -,/ BAND FOOTINGS SH GRADE EAST EXTERIOR ELEVATION SCALE: 1/4" • 1 '-0" 12 12 CLASS A FIRE RATING / -COMPOSITON ROOF SHINGLES BY GAF 31 -----------------------13 ICC ES ES R-14 7 5 ~--------~=~~~~~/~~""' OVER 30# FELT D[ □ □ NORTH EXTERIOR ELEVATION SCALE: 1/411 • 1'-011 --PAINTED METAL DRIP EDGE, TYP \ " \_ 2x8 FASCIA, TYP, "'-.. UON ON PLANS ----""--CEMENT PLASTER SIDING OR ---01!-lER SELECTED EXTERIOR FINISH #1 --- ------------------------ELECTRICAL 0UBPANEL ,-- ,-CONCRETE SLAB AND FOOTINGS _,..----··-EXIS l"ING & FINISH GRADE / - 6 ' in 0 0 ' " N _, ~ '\' -N '\' ,__ 2'-0" OH . - i - I I : I ' 33'-D' +-----------------------------~----------------------------------------+ 14'-0" 4'-0" 2'-8" 12'-4" +-----------~~----------,t~---"-C!___--t--=.:'c.__t--_____ ~~--------,c 7' 2" GREAT ROOM SLPD CLG, WO FLR 6'-10" 2'-0" 2'-0" 6'-0" 6'-4" 7 I I I I I I SLPD CLG, ilfVD FLR I 1 -----~ ~ ,m I ,;,_/ ! I I I <t>' I I -; I I I I I I 4'-6" 990 sf 11 '-8" 2'-4" I ' ,-,:-. KITCHEN SLPD CLG, WO FLR I I . , __ / ! ' ! j-._______, I - I I I ! I I I I I <~I I I ! 9 '" 0 _, "' ' 'r N -i :r "' 8'-0" 6'-0' 5'-1" 1'-7" 6'·0" 6'-4'' +--------'=------+---~~-~--J~-~~---.-~---,f--------~--------~~-----, I I I I I I i I fl- I I I -Jc------ I ~--- I I I! D DS 14'-0" ---6'-8" ------,r~--- 331 -0" FLOOR PLAN SCALE: 1/4" • 1'-0" ROOF PLAN SCALE: 1/4" -1'-0" r I u t- (L N OS 11 us PAINTED METAL GUTTER W/ DOWNSPOUT, TYP ~ ROOF OUTLINE, / lYP / ___ HATCH INDICATES ATTIC AREA, TYP ,~ BUILDING / PERIMETER, ' TYP --,-COMPOSITION SHINGLES, TYP RECEIVED DEC D3 2021 CITY OF CAnLSBAD PLANNING f)[VISION NO, REVISIONS: BY: 1 2 3 Q) u C Q) "C ·-a::: "' ~ Q) I-0::: z .c ::::, u C) ·-.... z .., _J Q) _J w ·-3: C Cl I >-Q) -a::: .., 0 .., (/) Q) (/) N w C (_) (_) ·-<( Q) 3: Q) .c I- ;1; CX) 00 N Ol O> (0 I I CX) <C '<l" E ur--o 0 I ----• CX) Ill >. L() § 0 CX) ·-3:: '-"•Ill 0 X ~ Cl.. 0 "O I ..,_ §, ·-"O (I) cl'~ 0 L() >, a::~ E l'.? I :i: Q) -.;t-3l: 3l: r--3l: 0 r-- 0.. ----r---CX) OL() (0 CX) I") .._,, .... 00 0 -o a., N a., en I.. -ca ti) ·- C: C: I.. 0 0 "' ..... s... ·--(1) ca a u (1) ~ -, "C "lit ca "lit .c <D "' N -I,,. m (J FLOOR PLAN ROOF PLAN EXTERIOR ELEVATIONS PLAN Fll.E NUMBERS CDP PLAN CHK PERMIT DATE: 8 -23 -21 SCALE: 1/4" = 1 '-0" JOB. NO. 210827 SHEET A-1