Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3156 LIONSHEAD AVE; ; FA080021; Permit
3/7/24,12:14 PM FA080021 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 3156 LIONSHEADAV Permit Type: FALARM Parcel No: 2218801700 Permit No: FA080021 Status: ISSUED Applied 2/26/2008 Approved: 2/26/2008 Lot #: 0 Reference No.: Issued: 2/26/2008 PC #: Inspector: Project Title: OPUS POINT, BUILDING 2 TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: Owner: BERG ELECTRIC 650 OPPER ST ESCONDIDO CA 760-746-1003 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 fAOOOZ( Bergelectric Corp. Contractors & Engineers TABLE OF CONTENTS FIRE ALARM SUBMITTAL CONTROL. PANEL INITIATING DEVICES 2 NOTIFICATION APPLIANCES . 3 BATTERIES 4 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 9 C 1048504 Bergelectric Corp. actors & Engineers CONTROL PANEL 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 9 Fax (760) 746-4619 9 C10485046 EDWRDSSVSTEP45 TECHNOLOGy Part of GE Iiuiittu CONTROL PANELS QSC Conventional life safety control panel Features U Supports up to 48 Class B or a combination of 40 Class A and Class B conventional circuits 12 Compatible with two- and four-wire smoke detectors U Failsafe mode ensures u ncom promised reliability 12 Capacity foreight remote annunciators 12 Four built-in system relays U Optional dual line dialer supports Contact ID and 4/2 formats U Three methods of programming: QuickStort "auto-learn,front panel and personal computer (PC) 12 Supports optional barcode scanner for direct device data entry U Two optional banks of 30 front panel switches with dual LEDs I Red or grey cabinets in two sizes for surface or semi-flush mount- ing U Four-line (80 character) backlit LCD display 12 Four password levels, plus priority access keyswitch U Message routing by event type or by individual message U 1,000 event history buffer, plus alarm history counter 12 6 amp Power Supply, 4.75 amps available for external use U ULC-S527-99 compliant U Compare utility identifies system changes and simplifies testing. Description EST's QSC life safety control panel provides a cost-effective solution for conventional life safety applications. Designed for easy setup and simple installation, QuickStort lives up to its name in every respect QSC's exclusive QuickStart auto-learn function, and the option of configuring the panel using convenient front panel programming or from a PC, makes short work of system setup. Text entry is easy as well. A few simple posses of the optional scanner is all it takes to store custom messages. QSC's setup routine is deceptively simple, considering this system's robust features. Supporting up to 48 conventional Class B or a combino- _____ MFA tion of 40 Class A and Class B initiating circuits, this panel leaves plenty of room to grow. QSC is compatible with either two- or four-wire detectors, and also provides built-in support for EST's EC family of conventional detectors. QuickStart's modular design brings flexibility to every installation. Quick- Lok option cords snap onto QSC's easily-accessible DIN mounting rails. These cards provide a dialer, auxiliary relays and additional system capacity. QSC also supports as many as eight remote annunciators and up to 60 programmable front panel switches with dual LEDs for system control and display. QSC is as simple to operate as it is to set up. Its easy-to-read four-line bocklit LCD display provides details concerning up to 1.000 system events, while bright system status LEDs and large, tactile control buttons present the user with a clean, crystal clear interface. Four password levels limit control and information retrieval to authorized personnel. A priority access keyswitch gives Level 2 access without a password to -management and emergency personnel. Application QSC is total life safety solution that merges flexibility, high system capacity, and robustfeatures with a cost-effective and installer-driven design. Ideal for small buildings, the QSC is perfectly suited for new and retrofit applications in schools, apartment buildings, hospitals, office buildings, and retail facilities. imagination at work -00, Www.gesecurity.com 8985 TOWN CENTER PARKWAY, BRADENTON, FL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES:OWEN SOUND, ON 519-376-2430: FAX 519-376-7258 INTERNATIONAL SALES: (001) 905-270-1731 ; FAx 10011905-270-9553 Literature Sheet #85005-0112 Issue 5 Not to be used for installation purposes. Page 1 of 8 NOT TO BE USED FOR I N STALLATION PURPOSES Operation Indicators Controls Text display and controls: Displays system messages, status information, and programming menus. Arrow buttons move the display cursor. Alarm LED: Indicates afire or life threatening emergency. Supervisory LED: Indicates an off-normal condition with the fire suppression system or related equipment Disable/Test LED: Indicates part of the system is disabled or being tested. Disabled components also signal a system trouble. S. Monitor LED: Indicates the operation of an ancillary system function (door closures, fan pressure switches). Trouble LED: Indicates an off-normal condition orwiring faultthat compromises the integrity of the system. Ground Fault LED: Indicates aground fault in the system wiring. Ground faults also signal a system trouble. cpu Fail LED: Indicates an unexpected reboot or failure with the microprocessor. CPU failures also signal a system trouble. Power LED: Indicates the panel has power. Help button: Provides additional information aboutthe device selected on the display. Status button: Displays the Status Menu from which you can identify active or disabled points in the system. Panel Silence/Acknowledge button and LED: Acknowledges all events posted in the display queues and turns off the panel buzzer. The panel silenced LED indicates that off normal events have been acknowledged. CPU / LCD Display The QSC front panel display provides four lines by 20 characters of text detailing event, device, diagnostic, and programming information. Its large backlit LCD screen is easy to read and always provides at-a- glance indication of the system's state of operation. The CPU/Display Unit houses the CPU card and mounting space for two optional LED/Switch cords. Display with one alarm shown Reset button: Allows devices or zones in alarm or trouble to restore to their standby condition. The LED indicates that the panel is resetting. Alarm Silence button:Turns active notification appliances off depending on panel programming. Pressing Alarm Silence a second time turns them back on. The LED indicates that the panel is in alarm and operating with notification appliances turned off. Drill button: Activates notification appliances depending on panel programming but does not place the panel in alarm. The LED indicates that the panel is in Drill Mode. Menu button: Displays the operator menus. Delete button: Returns to the previous menu or backspaces the cursor. Enter button: Press the Enter button to accept information or continue to the next item. Numeric keypad: Numbered buttons for entering values and making menu selections. Barcode scannerjack: Input for optional barcode scanner. Priority Access keyswitch: Enables control functions reserved for access level 2 and above without requiring a password. Specifications Operating environment Temperature: 32-120 ¶ (0-49 C} Humidity: 93 %RH, non-condensing Current Standby: 117 mA when connected to PS6; requirements 105 mA when connected as a remote annunciator Alarm: 135 mA when connected to PS6; 123 mA when connected as a remote annunciator Failsafe Mode If the CPU loses communication with other circuit cards, the power supply card continues to monitor the system for any alarm events. If an alarm occurs on any device or circuit during a communications failure, the power supply activates all alarm outputs and instructs the dialer to transmit a default alarm message to the monitoring station. www.gesecurity.com Page 2of8 Literature Sheet #85005-0112 Issue 5 QSC Panel NOT TO BE USED FOR INSIAL L.ATON PLIRPOSC, Tjpica Wiring Initiating Device Circuit - Class A Initiating Device Circuit - Class B Class B Notification Appliance Circuit with Genesis Signals and Signal Master for independent horn and strobe control and I- Notification Appliance Circuit ass with Separate Strobe V Circuits and Horn -- -, I LEGEND I Enhanced Integrity Genesis Genesis 2 Smoke Manual a Horn-StrobeEi~ Horn-Strobe Signal Master Detector Pull Station g suggestions can be found in the QSC Fire Alarm Control Panel , Operation, and Maintenance Manual, P/N 3100185. www.gesecurity.com Issue 5 Literature Sheet #85005-012 Page 3afB W:'.T 10 BE UFF El FOR N1ALLAllON puRFost; Standard Components nd Option Cards All QSC panels come standard with a CPU/Display Unit, or Power Supply (see ordering information for details). QuickStort option cards provide a wide range of features extra system capacity. Thanks to the convenient Quick-Lo mounting system, option cards snap onto the DIN mountil easily and securely. Wailboxes are available in two sizest room for either five or 12 single-space option cords. Both of wallbox feature easily-accessible mounting rails and p1 room for cabling. e PS6 provides primary dc power to all the .ircuit cards installed in the cabinet There are four 24 Vdc power output circuits - three for powering auxiliary applications, and one for powering four-wire smoke detectors - and a charging circuit for standby batteries. The PS6 also provides common alarm, supervisory, and trouble relays, as well as a fourth relay that is user programmable. S?TPCR NC MIZRNVO Wiring CNN CC. CC• AIRC CON OWJ CON TBZ I[010Il0 EoI@I@@I TBI CO C IC C IC C IC C mm * - * - CROIX NC RCA? I P5*12 RCA?, P5121 51CC P2115 P Relay 1: Formc.contactschonge positionwhenthe control panel processes onolarm signal and remain changed until all active alarm inputs restore and the control panel resets. Relay 2: Form A. contacts change position when the panel processes a supervisory signal and remains changed until oil active supervisory inputs restore. Relay 3: Form A. Contacts change positionwhenthe panel loses paweror processes atroublesignal and remains changed until power retumsorthe trouble clears. Relay 4: Form& Relay closes andopens according to panel programming. Smoke/Accessory Power: Jumper setting determines if the 24 Vdc isconstontorresettable. Specifications Main supply circuit AC input: 115 or 230 Vac, 50/60 Hertz DC input: 24 Vdc batteries Battery charging circuit Charge current: 2 amps Charge capacity: 40 amp hours JUL) 30 amp hours (ULC) Smoke/Accessory Voltage: 24 Vdc, regulated power output circuit Current: 250 mA Wire size: 12 to 18 (0.75 to 2.5 mm2) Auxiliary power Quantity: 3 Output circuits Voltage: 24 vdc full wave rectified Current: 1.5 amps each Common alarm relay Style: Form C Contact rating: 1 amp Wire size: 12 to 18 AWG (0.75 to 2.5 mm2) Trouble, Supervisory Style: Form A NO) and programmable Contact rating: 1 amp relays Wire size: 12 to 18 AWG (0.75 to 2.5 mm2) Operating environment Temperature: 32- 120° F (0- 49' C) Humidity: 93 %RH, non-condensing Current requirements Standby current: 72 mA Alarm current: 96 mA www.gesecurity.com Page 4of8 Literature Sheet #85005.0112 issue 5 NOT TO BE UCEL' FOR INSIAI.TAHOTI I11'RPJSE ZonCQrd, r IZAB-2 ZB164 The ZB16-4 Zone Card provides sixteen circuits for connecting Class B conventional input and TB1 output zones. Twelve circuits are dedicated initiating device circuits (IDCs) for connecting 2- wire smoke detectors and dry-contact initiating devices. Four circuits can be configured as either I DCs or as notification appliance circuits (NACs) for connecting polarized 24 Vdc notifica- tion appliances such as horns or strobes. TBZ Wiring (Z816-4) OlD 211 212 213 214 ElI ill RI 112 TB2 I®l 888688688 TB1 I-I -4- ----- 21 Z2 23 24 XE XE V ZR 26 The ZAB-2 Zone Card provides eight circuits for connecting Class A conventional inputand outputzones. Sixcircuits are dedicated initiating device circuits llDCsl for connecting 2-wire smoke detectors and dry- contact initiating devices. The remaining two circuits can be configured as either lDCs or as notification appliance circuits (NACslfor connecting polarized 24 Vdc notification appliances such as horns or strobes. Wiring (ZA8-2) 1 ZONER ZONER 200007 TM N*CPWR +0 +A- +6 +A +6 +* +0 +0- +04. TB2 )ANJAN()ANliAh EOLR 141( %1. EOLR H TB1 +004- Specifications ZB16-4 ZAB-2 Initiating device circuits Quantity 12 to 16 6t08 Wiring configuration Class B Class A Detector voltage 19.9 - 24.0 Vdc, max ripple 400 mV End of line resistor 4.7k ohms, ½W Short circuit current 31 mA, max. Resistance 50 Ohms, max. Capacitance 100pF, max. NAC power input circuit Voltage 24 Vdc Wire size 18 to 12 AWG (0.75 to 2.5 mm2) Notification appliance circuits Quantity 1 t 4 1 or 2 Wiring configuration Class B Class A End of line resistor 10k ohms, ½W Output voltage 24 Vdc, nominal Output current 2.0 A, 24 Vdc Wire size 18 to 12 AWG (0.75 to 2.5 mm2) Operating environment Temperature 32_1200 F (049R C) Humidity 93 %RH, non-condensing Current requirements Standby 123 mA 73 mA Maximum cards Three (48 zones) Five (40 zones) in panel 40 zones maximum when both ZB16-4 and ZA8-2 cards installed. Card Spaces Requires two card spaces. L L L L @0 0 The DLD is a ULI/ULC listed dual line Digital Alarm Commu- nicating Transmitter lDACT). lt provides two phone line _____ TB1 connections for sending system messages to a compatible Digital Alarm Communicator Receiver. The OLD supports 4/2 and Contact ID formats. It occupies one card space on the chassis rail. SURGE 1 ON 011000 Wiring R0O) - TIP TOPI401IELIIE 12 02010 (WIRED RARE AU 6 P. MOESLAR P1106! ONE CONNECTOR FOR P00050 ERIE 01 GREEN • 103701 OPEl MODULAR FO CONNECTOR R ___________ P01011000100*2 ® ROT.TAPU PERIETTED 10000000ØI7 TIP RNG TIP 000113 TIP RNG TIP RNG IN OUT IN OUT LINE I LINE 2 Specifications Operating environment Temperature: 32 - 1200 F (0490 C) Humidity: 93% RH, non-condensing Current requirements Standby: 13 mA Dialing: 26 mA Phone Lines Two loop start lines on switched telephone network. Pulse or DTMF dialing. Wall Connector RJ31X/CA31A equiv. or RJ38X/CA38A equiv. Communications Protocol Contact ID (SIA DC-05), 4/2 (SIA DC-02 P3). Programming Via QuickStart, Front Panel or PC. Communications Compliance Communications Canada CS-03FCC/CFR 47 Parts 15 and 68, NFPA 72, ULI 864, ULC S527-M87 Receivers Signals can be transmitted to either or both of two receivers. Telephone #s Two 24-digit numbers per receiver. Card spaces Requires one card space. www.gesecurity.com Issue 5 Uteroture Sheet 985005-0112 Page 5 of 8 Specifications Operating Temperature: 32- 120 F (0-49 C) environment Humidity: 93% RH, non-condensing Current Standby: 1mA requirements Alarm: 0.75 mA per active LED NOT TO BE USED FOR INSTALLATION PTIRfOSL OTN EWSwtchCds SL 3O1 The SL30 and SL30-1 provide thirty circuits for zone . annunciation. Each circuit comprises two LEDs and a push button switch. The SL30 push button switches are numbered from 1 t 30 and the SL30-1 push button switches are numbered from 31 to 60. The SL20LSS provides 20 circuits for point annunciation and five circuits for custom control functions.The SL30L provides 30 circuits for point annunciation. SL20L5S and SL30L circuits are labeled using inserts provided V with the cards. b' ReidCard ± I JZRB The ZR8 provides eight dry-contact relays that can be independently configured as Form A or Form B • TB1 relays. It occupies one card space on the chassis rail. Wiring R5-. •R6- *R7- •R8- ____ Iøøøøø®001T9 Y Y Y Y_ ____ __ Iø00ø0ø00IIs' TB2 'Ri- •R2- •R3- •R4- - Specifications Output relays Style: Form A (N/O) or Form B (N/C) (jumper configurable) Contact rating: 1 amp @ 30 Vdc resistive. Wire size: 18 to 12 AWG (0.75 to 2.5 mm2) Operating Temperature: 32 - 120° F (0 - 49° C) environment Humidity: 93 %RH, non-condensing Current Standby current: 7 mA requirements Alarm current: 18 ma per active relay Card spaces Requires one card space. riss IARS4S5 CadTTd The NT-A. which includes the X485/RS- 485 card and QS-232/UART port, provides one Class A serial remote annunciator bus for connecting remote annunciator panels. Control panels require the X485 card and QS- 232 port, which also serves as a laptop or printer port. The X485 occupies one cord space on the chassis roil. The QS-232 port plugs into the panel CPU. 012 011 IS-232 Wire size 12 to 18 AWG (0.75 to 2.5 mm2) twisted pair (6 twists per foot minimum) Circuit resistance 100 Ohms Circuit capacitance 0.4 pF Operating environment Temperature: 32 - 120° F (0- 49° C) Humidity: 93 %RH, noncondensing Current requirements Standby: 75 mA Alarm: 75 mA Card Spaces Requires one space for the NT-A Wiring Specifications www.gesecurity.com Poge6of8 Literoture Sheet #85005-01i2 Issue 5 5-Option Cabinet QSC-5-R-1 (red): QSC-5-G-1(grey) o 8 3,'. NOT 10 BE USED FOR INTA1 LIiTION P1iRP05C. Remote Annunciators The QSC front panel display provides four lines by 20 characters of text detailing event, device, diagnostic, and programming information. Its large backlit LCD screen is easy to read and always provides at-a-glance indication of the system's state of operation. The CPU/Display Unit houses the CPU card and mounting space for two optional LED/Switch cards. Remote annunciators connect directly to the PS6 Power Supply Cord or an external 24 Vdc filtered supply. They are available with waflboxes for flush or surface Remote onnunciator ICloss 8w1ring1 Remote Annunciator Dimensions Model Height Width Depth QSA-1-S 7.6" (19.46 cm) 14.25" (36.20 cm) 2.9" (7.3 cm) QSA-1-F (rough in) 6.56" (16.66 cm) 13.25" (33.66 cm) 2.1" (5.33 cm) QSA-1-F (finished) 7.8" (19.81 cm) 14.42" (36.63 cm) 1.38" (3.49 Cm) QSA-2-S 7.6" (19.46 cm) 18.56'(47.14 cm) 2.9" (7.3 cm) QSA-2-F (rough in) 6.56" (16.66 cm) 17.56" (44.60 cm) 2.1" (5.33 cm) QSA-2.F (finished) 7.8'(19.81 cm) 18.75"(47.63 cm) 1.38" (3.49 cm) Hough-in dimensions reflect the size of the cabinet where it enters the wall. Finished dimensions reflect the size of the cabinet that protrudes from the well. Cabinet Mounting 12 and 5-Option Cabinets 2.2" (5.6 cm) Cabinet Dimensions fl Optional Vandal ............' Vandai- Resistant Door (4.27 cm) Semi-flush Surface Mounting Mounting Semi-f ushmounlingrequires on optionoltrim ring, which oddsW(19 mm) tool! sidesofthe paneL (47.31 12-Option Cabinet QSC-12-R-1 (red(; QSC- 12-G- 1(grey) www.gesecurity.com Issue Literature Sheet #85005-0112 Page 7of8 NT TO BE USED FOR IN51A1iATION P LIP. POC. Ordering Information ,art Description Ship Wt. Number lb. (kg.) Basic Package -Enclosure, Power Supply, CPU and Display QSC-5-G.1 Conventional System. Five option card spaces. 17.0 Gray. 115v transformer. (7.71) QSC.5.R-1 Conventional System. Five option card spaces. 17.0 Red. 115v transformer. (7.71) QSC-12-13-1 Conventional System. 12 option card spaces. 30.0 Gray. 115v transformer. QS-Cablei2 required. (13.61) QSC-12-R-1 Conventional System. 12 option card spaces. 30.0 Red. 115v transformer. QS-Cable12 required. (13.61) Enclosure Accessories QS-2-VR Vandal-resistant cabinet door, gray 3.0 (1.36) QS-2-VR-R Vandal-resistant cabinet door, red 3.0(1.36) QS.Cable12 Expansion Cable for 12-option card cabinets. 0.5 (0.23) Trim-5 Gray Flush mount trim ring for QS-5-G-1. TO (2.27) Trim-5R Red Flush mount trim ring for QS-5-R-1. 5.0(2.27) Trim-12 lGray Flush mount trim ring for QS-12-G-1. 8.0 (3.63) Trim-12R Red Flush mount trim ring for QS-12-R-1. 8.0 (3.63) Initiating/Notification Circuit Option Cards ZB16-4 Conventional Zone Card. 16 Class B circuits, four convertible to Class B NACs. 2.0 Requires two option card spaces. (0.91) ZA8-2 Conventional Zone Card. Eight Class A circuits, two convertible to Class A NAC's. 2.0 Requires two option card spaces. (0.91) Other Option Cards DLD Dual Line Dialer. Supports 4/2 and Contact ID 1.0 formats. (0.45) RB Relay Card. 8 programmable Form A contacts. 1.0(0.45) .iisplay Options SL30 Annunciator module. Numbered 1 t 30. 1.0 Two LEDs and one switch per zone. (0.45) SL30-1 Annunciator module. Numbered 31 to 60. 1.0 Two LEDs and one switch per zone. (0.45) SL20L5S Annunciator module. 20 circuits for point annunciation. 5 circuits for custom functions. 1.0 Circuits labeled with insert card. (0.45) SL30L Annunciator module. Circuits labeled with insert card. 1.0 (0.45) QSC-CPU-1 Conventional CPU/Display. 4.0 One annunciator option space. (1.81) QSC-CPU-2 Conventional CPU/Display. 4.0 Two annunciator option spaces. (1.81) NT-A RS-485 option card. Required for Class A 1.0 remote annunciation. Includes UART card. (0.45) QS-232 UART option card. Plugs into CPU. Required for PC Programming / printer port. 1.0 Included in NT-A package (0.45) Part Number Description Ship Wt. lb. (kg.) Remote Annunciator Cabinets (c/w Interface Assembly; Require CPU/Display) QSA-1-S Surface Remote Annunciator Cabinet. Space for one SL30_display. 4.0(1.81) QSA-1-F Flush Remote Annunciator Cabinet. Space for one _SL3O_display. 4.0(1.81) QSA-2-S Surface Remote Annunciator Cabinet. Space for two _SL3O_displays. 5 0 2 27 QSA-2-F Flush Remote Annunciator Cabinet. Space for two _SL3O_displays. 5 0 (2 27) Programming Tools QS-CU IQuickStart Panel Configuration Utility. 1.0 (0.45) OS-Scan QuickStart scanner and programming guide. 2.0 (0.91) 260097 Programming cable (PC to QSC. QS1, QS4) 1.0 (0.45) 360136 Programming cable (PC to Annunciators) 1.0 (0.45) 240507 DB9 to RJ-1 1 (required with 360136) 1.0 (0.45) Accessories PT-11S SystemPrinter - Desk top Style 14.0 (6.35) BC-1(R) Battery Cabinet. Room for one 40 Ah or two 24 Ah batteries. 22.0 (9.98) MFC-A MultiFunction Cabinet. 7.0 (3.1) lOP3A RS-232 Isolator Module. 3.0(1.36) RPM Reverse Polarity Module. 3.0 (1.36) 2-CTM City Tie Module. 1.0 (0.45) API-8/232ME Alphanumeric Pager Interface 11.0 (5.0) BPS6 6.5 Amp Booster Power Supply, 110 V 13.0 (5.9) BPS10 10 Amp Booster Power Supply, 110 V 13.0 (5.9) CDR3 JPSNl Coder Module 1.0 (0.45) Ordering options (Apply to basic packages and CPU/displays only) Languages Power Supplies No suffix = American English 1 = 115v transformer SP = Spanish 1230v or 1150 2 = 230v transformer PG = Portuguese 1230v only) FR = French Canadian (120v only) Colors G = Grey enclosure (230v or 115v) R = Red enclosure lllsv only) Examples QSC-5-G-2-SP = QSC basic package with five option cord spaces, grey enclosure, 230v transformer, Spanish language. QSC-CPU-2-FR = QSC CPU/display, two annunciator option spaces. French Canadian. Which Quickstart Panel is right for you? QSC QS1 QS4 Signature Series devices supported 0 1 x 250 4 x 250 Conventional Class B circuits supported 3 x 16 0 3 x 16 Conventional Class A circuits supported 5 x 8 0 5 x 8 LCD display (lines x characters) 4 x 20 14 x 16 14 x 16 Optional Zone Switch/LEDs on front panel 2 x 30 1 x 30 2 x 30 Option card spaces 5 or 12 1 5 or 12 For more information, see catalog sheet number ... This Sheet 85005 -0113 85005 -0114 www.gesecurity.com It is our intention to keep the product information current and accurate. We can not cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information or questions relative to this Specification Sheet. Contact GE Security. © 2004 GE Security Printed in u.S.A Page 8of8 LiteratureSheet#85005-01I.2 Issue 5 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:207 Page 1 of I CATEGORY: Control Unit (Non High-Rise) LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models QSC, -QSI and -QS4 fire alarm control units, followed by —1 or-2 followed by-BR, -SP, - FR, -PG or no suffix. Local, local with shunt, auxiliary, remote station, releasing service or central station. Power limited. Non-coded, coded, shunt, reverse polarity, DAd, manual, automatic waterflow, and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System Components: QSC,QSI,QS4 7200001-01, -02; 7200004-01, -02 7200005-01,-02 PS6 ZBI6-4 ZA8-2 DLD ZR8 NT-A QS232, 232 SL3O SL-30-1 SLIC QS-1-VR, -R, QS-2-VR, -R SL3OL SL2OL5S Control Units Enclosures Enclosures Power supply Class B zone card Class A zone card Dialer (DACT) card Relay card Class A, RS485 communications card Port for download or printer functions LED/Switch card with switch 1-30 LED/Switch card with switch 31-60 Signature expansion loop card. Vandal resistant doors LED Cards 30 Zones LED/Switch Cards 25 Zones RATING: INSTALLATION: MARKING: APPROVAL: NOTE: 120/220 VAC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Units can also generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. This control unit meets the requirements of UL-864, 8th Edition Standard. I. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-1591:207 and 7165-1388:237 08-17-05KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 11, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager Bergelectric Corp. Contractors & Engineers INITIATING DEVICES 650 Opper Street • Escondido, CA 92029 9 Tel (760) 746-1003 • Fax (760) 746-4619 • C10-#85046 EDWARDS SYSTEI'IR TECHNOLOGY Part of GE T1.1,llkt! COMITEATIONAL INITIATING DEVICES Low-profile Plug-in Photoelectric Detector EC3OU-3 Features 8 Sensitive to visible and invisible products of combustion Finely tuned to sense all fire types, especially slow burning, smolder- ing fires fuelled by combustibles typically found in modern multi-use buildings. 2 Stable, reliable design Uses the light scattering principle for smoke detection and is not affected by air movement 8 Non-polarized Simplifies installation of field wiring 2 Simple to install, difficult to vandalize Twist-and-lock design saves installation and maintenance time. Field- configurable locking mechanism prevents unauthorized removal. ta Flexible mounting options Compatible standard base mounts to 1-gong, 4" octagonal. BESA. or European single-gang boxes. LI At-a-glance alarm indication An on-board high-intensity LED glows bright red when the unit is in alarm, making alarm response a simple and straightforward opera- tion. LI Easy to maintain Removable housing and insect mesh facilitates cleaning. 8 Attractive appearance with clean, modern lines Low-profile design blends easily with surroundings, extending less than 2W (61 mm) from the ceiling, including base. The installation and maintenance advantages of the EC30U-3 add value to this detector throughout its service life. Its twist-and-lock design makes short work of installation and maintenance operations. A plastic breakout on the detector housing optionally prevents removal from the base except with a special toot. A bright, easy-to-see LED on the detector glows steady when it is in alarm, thus eliminating much of the guesswork when responding to front-panel indications. If a detector is removed for any reason while the panel is in its normal state, ozone trouble condition will result. This ensures the integrity of the alarm system at all times. EC30U-3 detectors are manufactured to strict international ISO 9001 standards. All electronics employ surface mount technology (SMT) for smaller size and greater immunity to RF noise. A corrosion-resistent conformal coating is used to seal components against dust and humidity. Shown v ordered Description Application EC30U-3 low-profile plug-in photoelectric detectors measure-up to the quality and performance standards that have made GE Security fire Thanks to its high-performance photoelectric sensor, the EC30U-3 detection products the industry's best price-performance buy available responds quickly and reliably to all fire types, especially slow burning today. Meticulously engineered to deliver high-performance features. fires fuelled by combustibles typically found in modern multi-use superb reliability, and unbeatable quality, the EC30U-3 is a low-cost buildings. Particles as small as 0.5 microns will be detected by the solution for conventional detection applications, sensing element, triggering an alarm at the first sign of smoke. The EC30U-3 distinguishes itself as a performance leader in its class GE Security recommends that all detectors be installed according to the with its highly stable design that resists air movements caused by latest recognized edition of national and local fire alarm codes. heating and air conditioning, and changing environmental conditions. This makes it reliable performer ideally suited to modern building interiors. 0 imagination at work www.gesecurity.com 8985 TOWN CENTER PARKWAY, BRADENTON, FL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES: OWEN SOUND, ON 519-376.2430; FAX 519-376-7258 INTERNATIONAL SALES: 1001)905-270-1711: FAX 10011905-270-9553 Literature Sheet #85001-0552 Issue 2 Not to be used for installation purposes. Page 1 of 2 1 24. (61 mm) 4.65 (118 mm) Mounting Wiring The detector mounting bases will accept#18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2) and #12 AWG (2.5mm2) wire sizes. CSBU-1: Standard detector base Provides plug-in tamper- resistant mounting. Includes screwterminols for connection of installation wires. NOT 10 BE LJSCD FOR INSTALLATION PL'RF0SF. Compatibility Panel model Zone model Maximum Detectors Zone ID UL ULC UL I ULC QuickStart ZA8-2, ZB16-4 40 30 100 EST1-2Z3, -2Z3R, -2Z6, -2ZR 46213-2101, -2102, -2104, -2105 40 00 EST3 lDC8/4 48 3D 00 1 0.0 LSS4/12(R), LSS4/36(R), LSS4/52(R) 8ZEXP, 4CLA, Motherboard 48 0.0 LSS4(R) 4ZEXP 48 0.0 IRC-3 130108, 240113, 240119 48 3289B 130082, 48 3289A 240124 (RZB12-6 only) 48 5389 FCC 130108, 240113, 240119 48 3289B 130082 48 3289A FireShield CPU 24 24 100 1 100 Specifications Operating Voltage Range 14- 30 Vdc Normal Operating Current 62pA Alarm Current 100 mA (max.) limited by control panel Sensitivity Range 1.38- 3.08% obs/ft Test Feature Sensitivity reading using Test/Picker Tool Operating Environment Altitude Not Applicable Temperature 32° F to 100° F (0° C to 38° C) Humidity 20 - 95% RH (non condensing) Air Velocity a - 5,000 ft/mm (manufacturer rated) 0- 300 ft/mm (UL listed) Storage Environment Temperature 32° F to 120° F (0° C to 49' C) Maximum Spacing 30 ft (9.1 m) centers Construction White molded high-impact fire-retardant plastic UL Compatibility ID A Compatible Bases See Ordering Information Ordering Information Model Description Ship Wt. lb (kg) EC30U-3 Low-profile Plug-in Photoelectric Detector 0.25 (0.11) CSBU-1 Standard detector base 0.11(0.05) CSB4U-1 4" Standard detector base CRB4U-1 4' Detector base with relay CSBU-3 Detector base with resistor EC-LED Remote Alarm LED 0.4 (0.18) C-TRIM Trim skirt for standard base 0.4 (0.18) C-PST Detector picker/sensitivity tester 1.4 (0.64) EC Series with Standard Bose Standard bases mount to the following electrical boxes: North American 31h inch octagon boxes North American 4 inch octagon boxes North American 1-gang electrical boxes European 1-gang boxes with 60.3 mm fixing centers European BESA boxes www.gesecurity.com It is our intention to keep the product information current and accurate. We can not cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information or questions relative to this Specification Sheet, contact GE Security- 0 2003 GE Security Printed in u S.A Page 2 of 2 literature Sheet #85001-0552 issue 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:135 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models EC30U-3 and *EC30DU3 photoelectric type, 2-wire smoke detectors. *The EC30DU-3 is a potted version of Model EC301J-3 the potting material is used to prevent air leaks and is used in applications for duct detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12-30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units. *Model EC30DU-3 may be used as a duct smoke detector. NOTE: Formerly 7272-1591:135 and 7272-1388:245 *Rev. 09-29-2005 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marsha! Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7271-1657:214 Page 1 of I CATEGORY: Ionization Smoke Detector LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models CSBU-1 and CSBU-3 smoke detector bases. Model CSBU-3 is similar to the CSBU- 1 except that CSBU-3 employs resistors inside the base. Bases are for use with Models ECIOU-3, EC30U-3, smoke detector heads and Models EC20FTU-3 and EC20RRU-3 heat detector heads. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an ionization smoke detector base for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7271-1591:214 08-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager EDWASDS SYSTEMS TECHNOLOGY Part of GE Security CONVENTIONAL INITIATING DEVICES Fire Alarm Stations 270 Series Features Pull lever 8 Simple positive operation 2 Breakglass 2 Attractive, streamline design 2 Less than 5 lb pull force complies with ADA 2 Solid, die-cast metal construction Description The GE Security 270 Series Non-Coded Fire Alarm Stations are sturdy, attractive, and designed for economical installation. The station is available in the following operational and functional designs: - The 270 Series provides a single action, break glass initiating station. It is available with normally open (N.0.), normally closed (NC.) or combination N.O./N.C. contacts. The basic 270 Series have screw terminals for field connection. The 270A Series Manual Stations have 6 inch (150mm) wire leads. - The 270P Series is a break glass, normally open pre-signal station. The pull of the lever sounds an alarm on all pre-signal indicating devices. Inserting a key and turning it will initiate a general evacua- tion alarm. Screw terminals are provided for field connection. 0 MEA All non-coded statins are designed for either flush or surface mounting. For flush mounting a 4 inch standard North American square box with single gang plaster cover should be used. For surface mounting the 270 Series or 270P Series, use P-027193 Cast Box, P-039250 Steel Box. or Cot. No. 1291 Housing for weatherproof enclosure. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. Ordering Information All models are fire alarm red with Aluminum Strips. They are marked "Pull in Case of Fire" on the pull handle. Cat. No. Marking (top of device) Switch Contacts Field Connections Pre-Signal Single Pole Double Pole Open Circuit Screw Terminals Wire Leads 270-DPO Fire Alarm x x x 270-DPO-L Local Alarm x x x 270.SPO Fire Alarm x x x 270A-DPO Fire Alarm x x x 270A-SPO Fire Alarm x _________ x x 270P-DPO Fire Alarm x x x x 270P-SPO Fire Alarm x x x x 0 imagination at work www.gesecurity.com 8985 TOWN CENTER PARKWAY, BRADENTON, FL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES: OWEN SOUND, ON 519-376-2430; FAX 519-376-7258 INTERNATIONAL SALES: 10011905-270-1711; FAX 10011905-270-9553 Literature Sheet #85001-0303 Issue 6 Not to be used for installation purposes. Page 1 of 2 NOT 10 BE USED FOR i NSTALI.ATION PUP.P0SE Mounting DOOR RELEASE I TEST & RESET AND .SS REPLACEMENT DEN ALARM KEY SWITCH S.P.S.T. (INCLUDED WITH PR-SIGNAL STATIONS) ONLY r(25'imTr WALL SURFACE INCLUDED WITH PR-SIGNAL STATIONS) ONLY 31 DETAILS FLUSH MEG. _I\,j UNIT FITS 4 SO BOX & PLASTER COVER WITH J SINGLE GANG OPENING P27165 GLASS ROD HAVING OVERALL MIN. DEPTH 0F2114' FLUSH INSTALLATION USING P024900 STEEL BOX 3-5/3r (80mm) 0 FRONT STEEL SURFACE BOX P.039250 3-hr F— (80mm) J 4-hr (114mm) FRONT 3-hr (89mm) (25mm) b SIDE 1- 3-9/hr (25mmTE(90mm) 4-9/16 (116mm) 0 CAST SURFACE BOX P-027193 SIDE www.gesecurity.com It is our intention to keep the product information current and accurate. We con not cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information or questions relative to this Specification Sheet. contact GE Security. © 2004 GE Security Printed in USA Page 2of2 Literature Sheet #85001-0303 Issue 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1657:111 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models 270,270P, 270-SPO, 270A-SPO, 270-DPO, 270A-DPO, 270-DOC, 276B, 277B, 278B, 279B, 279TC, 279P, 279T, 279L, 276A-REL, 278A-REL, 5966B, 5966BR, 5966BV, 5966BRV, 6296B-270,6296B-K279, 6296B-T279, 8557-13301, 8557-13311, 8558-13301, 8558-13311 and 8558-13312 manual pull stations. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as non-coded fire alarm pull stations for use with separately listed compatible fire alarm control units. NOTE: 1. Models provided with two-wire lead and normally closed switch contacts are not approved for fire alarm signaling use. 2. Formerly 7150-1591:111, 7150-1388:121 and 7150-0073:117 08-15-05 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager Bergelectric Corp. actors & Engineers NOTIFICATION APPLIANCES 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 • C10-#85046 One or more patents pending. I.iu1IIt. NOTIFICATION APPLIANCES 1777777 777,77 -7 77,77 Field Configurable Horns and Strobes G Series Features Unique low-profile design - The most compact UL-1971/ULC-5526 listed strobe available - Ultra-slim -protrudes less than one inch from the wall Attractiveappearance No visible mounting screws Four field-configurable options in one device - Select 15, 30, 75, or 110 cd strobe output - Select high (default) or low dB horn output - Select temporal (default) or steady horn output - Select public mode flash rate (default) or private mode temporal flash I Easy to install - Fits standard 1-gong electrical boxes - no trim plate needed - Optional trim plate accommodates oversized openings - Pre-assembled with captive hardware - #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Industry's most even light distribution - Meets tough synchronizing standards for strobes - Single microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control over a single pair of wires - Highly regulated in-rush current - Multiple frequency tone improveswall penetration - Industry's firsttemporal strobe output Description The Genesis line of signals are among the smallest, most compact audible-visible emergency signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, GE Security Genesis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions Iightto produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLighttechnology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result. Genesis strobes with FullLight technology go well beyond the minimum UL-required T" pattern, significantly exceeding UL-1971 and ULC-S526 light distribution requirements. Although all Genesis strobes are self-synchronizing, when installed with an optional synchronization module, strobe flashes from devices on the some circuit synchronize to within 10 milliseconds of each other indefinitely. This exceeds the two-hour minimum specified in the UL standards. Only one synchronization module is required per circuit Genesis strobes and horn-strobes offer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the device. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unauthorized tampering. Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent wall penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with ajumper cut that reduces horn output by about 5 dB. Genesis signals feature textured housings in architecturally neutral white ortraditional fire red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occupants regardless of what language they speak Models with "FIRE' markings are also available. 0 imagination at work www.gesecurity.com 8985 TOWN CENTER PARKWAY, BRADENTON, EL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES: OWEN SOUND, ON 519-376-2430; FAX 519-376-7258 INTERNATIONAL SALES: (001) 905-270-1711: FAX 1001)905-270-9553 Literature Sheet #85001-0573 Issue 3 Not to be used for instellation purposes. Page 1 of 6 NOT TO itt IJ5tr,I F,'.R INSTALLATION NIRPC.SF ienesis strobes are UL 1971-listed for use indoors as wall-mounted public-mode notification appliances forthe hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA 187dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with oisobilitiesAct (see application notes- USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes The following guidelines are based on ANSI/NFPA 72 National Fire Alarm Code (1999). When applied and installed in accordance with that code. GE Security strobes meet or exceed the illumination produced by the ADA-specified 75 candela (cdl strobe at 50 feet* Non-Sleeping Rooms EST wall mounted strobes* Up to 20'x 20'(6.1 m 6.1 m) One 15 cd strobe Up to 30'x 30'(9.1 m 9.1 m) One 30 cd or two 15 cd strobes Up to 40'x 40(12.2 m x 12.2 m) One 75 cd or two 30 cd strobes Up to 50'x 50(15.2 m 15.2 m) One 110 cd or two 75 cd strobes Corridors Any length. Maximum width: 20'(6.1m). 15 cd strobes spaced at 100' (30.5 m) max. Strobes must be placed within 15'(4.5m) of each end of the corridor. ADA suggests using 75 cd strobes throughout an area, with spacing that never exceeds 50 ft from the strobe to any point in the protected space. n-Sleeping Rooms and Corridors: GE Security strobes rated at less than 110 cd per UL 1971 are intended for use in non-sleeping areas only. Install with the bottom of the device at least 80 inches 12.0 ml and no more than 96 inches (2.4 ml above the finished floor. No point in any space (including corridors) required to have strobes should be more than 50 feet (15.2 ml from the signal (in the horizontal plane). For detailed spacing requirements, consult The Handbook of Visible Notification Appliances for Fire Alarm Applications published by GE Security Press, or contact your local GE Security representative. Sleeping rooms: GE Security 110 cd strobes are intended for use in sleeping rooms and should be installed along with a smoke detector. It must be wall mounted at least 80" (2.03 ml above floor level, but no closer than 24 (610 mm) to the ceiling. The distance from the strobe to the pillow must not exceed 1614.8 ml. Sleeping Rooms EST wall mounted strobe Any size 110 cd within 16 feet of pillow Horns The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet 11.5 ml above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 d reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Application Notes - USA Audible signals in the public mode should never have a sound level less than 75 dBA at 10(3 ml per NFPA 72. Signals cannot exceed 120 dBA per ADA and NFPA 72 at the minimum hearing distance to audible appliance. Strobe and combination horn/strobe devices should be installed with the bottom of the device at least 80 inches (2.0 ml and no more than 96 inches 12.4 ml above the finished floor. Horns should be installed with their tops not less than 6 inches 1152 mm) below the ceiling and not less than 90 inches 12.3 ml above the finished floor. Strobes must be used to supplement audible signals wherever the overage ambient sound level exceeds 105 dBA. Combination audible/ visual signals must be installed in accordance with NFPA guidelines established for strobes. ADA requires visible signals in the following areas; rest rooms, meeting rooms, and other common use areas. sleeping rooms intended for use by persons with hearing impairment (in accordance with Title 1 o ADA). work areas used by a person with a hearing impairment (per Title 1 of ADA). Application Notes - Canada (Based in part on 1995 Canada National Building Code) The fire alarm signal sound pressure level shall not exceed 110 dBA in any normally occupied area. The sound pressure level from an audible signal in a floor area used for occupancies other than residential occupancies shall not be less than 10 dBA above ambient levels, and never less than 65 dBA. In sleeping rooms the sound pressure level from an audible signal shall not be less than 75 dBA when any interven- ing doors between the device and the sleeping room are closed. Audible signal devices shall be installed not less than 1.8 m to the center of the device above the floor (per CAN/ULC S5241. The fire alarm audible signal shall be supplemented by fire alarm strobes in any floor area where the ambient noise level exceeds 87 dBA or where the occupants of the floor area use ear protective devices, are located within an audiometric booth, or are located within sound insulating enclosures. This also applies to assembly occupancies in which music and other sounds associated with performances could exceed 100 dBA Strobes shall be installed in a building so that the flash from one device is visible throughout the floor area or portion thereof in which they are installed. For maximum safety. GE Security recommends that strobes be installed as per the guidelines shown here under Strobe Spacing. www.gesecurity.com Page 2 of 6 LIterature Sheet #85001-0573 Issue 3 Genesis Horn/Strobe with optional trim plate NOT 10 SC USED FOR lNlALLATlON PVRP0SE. Installation Genesis horns and strobes mount to any standard one-gang surface or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gang, four- inch square, or octagonal boxes, and European 100 mm square. All Genesis signals come pre-assembled with captive mounting screws for easy installation. Two tabs at the top of the signal unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Field Configuration Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. Units may be config- ured for use with coded systems by cutting ajumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit. A Genesis Signal Master is required when horn-strobe models are configured for coded systems. Non- temporal, horn-only models sound a steady tone. Genesis strobes and horn-strobes are shipped from the factory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting ajumper on the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Horns and horn-strobes are factory set for high dB output Low dB output may be selected by cutting ajumper on the circuit board. This reduces the output by about S dB. Wiring Field wiring terminals accommodate #18 to #12 AWG 10.75 mm2 to 2.5 mm211 wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. no Polarity alarm next device end of line device Note: Strobes must have continuous voltage. www.gesecurity.com Issue 3 LIterature Sheet #85001-0573 Page 3 of 6 WOl TO BE USED FOR INSTALLATION PURPOSES specifications Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Lens Optical grade polycarbonate (clear) Mounting Flush mount: 2½ inch (64 mm) deep one-gang box (indoor wall mount only) Surface mount: EST model 27193 surface mount box, wiremold box, or equivalent surface-mount box With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor only: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Agency UL 1971, UL 1638, UL 464, ULC S525, ULC S526, CSFM, CE, FCC, (MEA, FM pending). listings/approvals (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions (HxWxD) Signal: 4-1/2'x2-3/4°x 13/160 (113mmx68mmx21 mm) Trimplate: 5"(127 mm); Height— 5-7/8'(149 mm); Depth - 1/2'(13 mm) G1-HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional G1M Genesis Signal Master) G1-VM series strobes: non-coded, filtered 16 - 33 Vdc or unfiltered 16-33 Vdc FWR G1-P series steady-tone horns: coded or non-coded, filtered 20-31 Vdc or unfiltered 20-27 Vfwr Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output G1-VM strobes and G1-HDVM series temporal-tone horn-strobes: one flash per second synchronized with Strobe as b flash rate optional G1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1 Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Compatible synchronization G1M, G1M-RM, SIGA-CC1S, SIGA-MCC1S modules G1-HD temporal-tone horns and G1-HDVM series temporal-tone horn-strobes: temporal rate synchronized Horn pulse ate P r with optional G1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) G1-P steady-tone horns: continuous, steady tone only Ternporai audible pattern 1/2 sac ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 11/2 sec OFF, then repeat cycle dBA output Temporal Horns. Horn-strobes (G1-HD. G1-HDVM series) - Hiah dB Settina ________ UL464 Average Peak Temporal Steady Temporal/Steady Temporal/Steady 16Vdc 81.4 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 96.9 99.5 Temporal Horns. Horn-strobes (G1-HD. G1-HDVM series) - Low dB Settina UL464 Average Peak Temporal I Steady Temporal/Steady Temporal/Steady 16 Vdc 76.0 80.1 86.3 89.2 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 95.3 Steady Tone Horns 1131-P series) UL464 Average Peak 16 Vdc 77 90 91 24 Vdc 77 90 91 33 Vdc 77 90 91 Notes All values shown ore dBA measured at 10 feet (3.01m). U1464 values measured in reverberation room. Average and Peak values are measured in onechoic chamber. Average Sound Output (dBA) (High dB setting, anechoic, 24V, measured at lOft) ITRAR"', WWI .77 75, Light output-(effective cd) Percent of UL rating versus angle Do. LN www.gesecurity.com Page 4 of 6 Uterature Sheet #85001-0573 Issue 3 Measured by EST F91fifiC RA... 24 Vdc 10 10 24 Vdc 11 11 31 Vdc 12 12 20 Vfwr 9 8 24 Vfwr 10 9 NOT 10 BE USED FOR INSTALLATION PURPOSE-1 Current Draw Strobes, Horn-Strobes Multi-cd Wall Strobes (G1-VM) lii N niata Rstinr, liii 1Q71 ffmtk,a Mm, 9fln&I 15 c 30 c 75 c 110 c RMS RMS RMS RMS 16 Vdc 103 141 255 311 16 Vfwr 125 179 346 392 Typical Current (Measured by EST) 15 c 30 c 75 c 110 c RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 85 79 127 124 245 243 285 283 20 Vdc 71 66 98 96 188 186 240 238 24 Vdc 59 55 82 80 152 150 191 190 33 Vdc: 46 44 64 63 112 111 137 136 16 Vfwr 119 64 169 97 1 332 203 376 240 20 Vfwr 103 51 143 76 253 150 331 198 24 Vfwr 94 44 129 65 218 121 262 1 152 33 Vfwr 87 .37 112 52 179 89 205 106 Multi-cd Wall Temporal Horn-strobes (G1-HDVM) - High dB Setting UI Nameolate Ratina fUL1971- Effective Mv 20041 15 c 30 c 75 c 110 c RMS RMS RMS RMS 129 167 281 337 176 230 397 443 Tvoical Current (Measured by EST1 15 c 30 c 75 c 110 cd RMS Mean RMS I Mean RMS Mean RMS Mean 16 Vile 102 89 135 129 246 242 309 305 20 Vdc 88 77 109 104 193 190 248 243 24 Vdc 81 71 94 90 161 158 203 200 33 Vdc 1 74 64 72 74 124 121 154 151 16 Vfwr 144 77 182 106 352 212 393 249 20 Vfwr 141 1 68 1 162 87 274 158 362 210 24 Vfwr 136 1 65 152 76 235 133 282 165 33 Vfwr 125 1 54 144 65 201 101 232 123 Multi-cd Wall Temporal Horn-strobes (G1-HDVM) - Low dB Setting ill Nan,anlata Ratinn till 1Q71 Fffa,th, Mm. 7flflAt 15 c 30 c 75 c 110 c RMS RMS RMS RMS 122 160 274 330 162 216 383 429 Tvoical Current (Measured by EST) 15 e 30 c 75 c 110 c RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 96 84 130 124 243 240 302 297 20 Vdc 79 70 104 99 189 186 241 237 24 Vile 68 61 88 84 156 154 197 193 33 Vdc 56 52 71 68 118 116 146 143 16 Vfwr 128 69 180 104 344 204 389 244 20 Vfwr 118 60 157 84 266 156 343 200 24 Vfwr 113 54 144 74 230 128 279 161 33 Vfwr 112 48 137 64 197 99 226 117 Horns Wall Temporal Horns (G1-HD) III Narnanlata Ratinn fill APA Mm, 9flflA% High dB Low dB RMS RMS 16 Vdc 26 19 24 Vdc 36 27 33 Vdc 41 33 16 Vfwr 51 37 24 Vfwr 69 52 33 Vfwr 76 70 Typical Current (Measured by EST) High dB Low dB RMS Mean RMS Mean 16 Vdc 22 17 17 14 20 Vdc 24 19 19 16 24 Vdc 27 21 22 18 33 Vdc 32 25 26 22 16 Vfwr 34 15 30 14 20 Vfwr 40 19 34 16 24 Vfwr 45 21 38 18 33 Vfwr 52 24 47 22 Wall Horns (GI-P) UL Nameplate Rating I I M.s 16 Vdc 9 7 24 Vdc 11 9 33 Vdc 13 11 16 Vfwr 9 5 24 Vfwr 10 7 33 Vfwr 11 9 Notes and Comments Current values are shown in MA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. GE Security recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AK calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. S. Fuses, circuit breakers and other avercurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flawing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. 6. Our industry has used mean currents over the years. However. UL will direct the industry to use the 2004 RMS values in the future. 16 Vdc 16 Vfwr 16 Vdc 16 Vfwr www.gesecuritg.com Issue 3 Literature Sheet #85001-0573 Page 5 of 6 OT TO BE U SED OR INSTALLATION }URrOLE; Ordering Information Catalog Number Description Ship Wt. lbs (kg) White Finish Red Finish G1-HDVM G1R-HDVM Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, selectable high/low dB output) 0.25 (0:11) G1-VM G1R-VM Genesis Strobe (selectable 15, 30, 75, or 110 cd output) G1-HD G1R-HD Genesis Temporal Horn (selectable high/low dB output) G1-P G1R-P Genesis Steady Horn (not compatible with Genesis Signal Master) G1FHDVM G1RF-HDVM Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, selectable high/low dB output) —with "FIRE" marking G1F-VM G1RF-VM Genesis Strobe (selectable 15, 30, 75, or 110 cd output) —with "FIRE" marking G1F-HD G1RF-HD Genesis Temporal Horn (selectable high/low dB output) - with FIRE" marking G1F-P G1RF-P 1 Genesis Steady Horn with "FIRE" marking (not compatible with Genesis Signal Master) Mounting Accessories [r G 1 RT Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) G1T-FIRE GiRT-FIRE Genesis Trim Plate (for two-gang or 4 square boxes) with FIRE" markings 0.15 (0.7) 27193-16 27193-11 One-gang surface mount box 1(0.4) Synchronization Modules G1M Genesis Signal Master — Snap-on Mount 02(0 1) G1M-RM Genesis — Remote Mount -gang) _Signal _Master _(1 SlGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) SlGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 (0.08) Genesis Horn-Strobes may • be ordered in red or white, with orwithout FIRE FIRE marking. 1INT MR 3.: 1 ;~& WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. These visible signal appliances' flash intensity may not be adequate to alert or awaken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. GE Security recommends that strobes in sleeping rooms be 110 cd minimum. 'enesis and FuilLight Strobe Technology are trademarks of GE Security, Inc. www.gesecurity.com It is our intention to keep the product information current and accurate. We cannot cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information or questions relative to this Specification Sheet, contact GE Security. 82005 GE Security Printed in U.S.A. Page 6 of 6 Literature Sheet #850010573 Issue 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:202 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models "EST" GI-HVI5, -HV30, -HV60, -HV-75, GI-HOVI5, -HOV30, -HOV60, -H0V75, -HOVIIO, GIF-HOVI5, -HOV30, -HOV60, -H0V75, -HOVIIO, GIRF-HOVI5, -HOV30, -HOV60, -H0V75, -1-IOVI10, GI-HDVM, GIR-HDVM, GIF-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, *GCFR..HDVM GCF- HDVMH, GI-HDV1575, GI R-HDV1575, GI F-HDV1575, and GI RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33 VdcN,r - Models GI-HDVM, GIR-HDVM, GIF-HDVM, GIRF- HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, *GCFRHDVM GCF- HDVMH, GI-H0V1575, GI R-HDV1575, GI F-HDV1575, GI RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, ll0cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, *GCFR..HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, G1 R-HDV1575, G1 F-HDV1575, GI RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135- 1657:230). For indoor use and wall mount only. Models GC-HDVM, *GCFR..HDVM and GCF-HDVM for ceiling mount only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *112706 kv This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 81 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager Bergelectric Corp. actors & Engineers BATTERIES 650 Opper Street 9 Escondido, CA 92029 • Tel (760) 746-1003 9 Fax (760) 746-4619 9 C10485046 UB12120 (12V12Ah) NOTE Nominal Voltage 12V Nominal Capacity (20HR) 12Ah Length 151 +/.-1mm(5.94 inches) D. Dimensions Width 99 +/-lmm(3.90 inches) Height 96 +/-2mm(3.78 inches) Total Height 102 +/-2mm(4.02 inches) Weight Approx. 4.0 kg (8.821bs) Standard Terminal Fl - Faston Tab No.187 Sloodard Termiaal mm Fl (Fast Tab No. 17) 4 IS E "P: I I Optional Tenninal mm P2 (Flit Tab No, 25) UB12120 (12V12Ah) 20 hour rate (0.35A) 12 Ah Max. Discharge Current (5 sec.) IOOA Capacity 10 hour rate (0.63A) 10.8 Ah 5 hour rate (1.12A) 9.6 Ah Initial Charging Current less 1 hour rate (4.2A) 7.2 Ah Cycle than 3.6A Voltage 14.40V — Constant 15.00v at 20°C(68°F) Temp. Coefficient-30mV/°C 40°C(104°F) 105% Capacity affected 20°C(68°F) 100% Voltage by Temperature 0°C(32°F) 85% Charge Standby Initial Charging Current less than 3.6A Voltage 13.50V 13.80V at Internal Resistance Fully charged battery (20°C, 20°C (68°F) 68°F) 20mil1iohms Temp. Coefficient-20mV/°C - - - - - - I3i = ..—..- = = J2. - .. . = - j 1.921 to _o - - -- 1.0 1 23 5 10 2030 60 23 5 JO 20 30 IT Disdiare Time ¼hhancfrIh °CO2°F.U°c1j! - - 1 - - - - - - I 30 (mb) irc iivc l (32 fl DdTargeCurreIIt