Loading...
HomeMy WebLinkAbout6359 PASEO DEL LAGO; ; AS160078; Permit2/15/24,11:20 AM ASI 60078 Permit Data City of Carlsbad Sprinkler Permit 6359 PASEO DEL Job Address: LAGO Permit Type: SPRINK Parcel No: 2130920900 Lot #: 0 Reference No.: Permit No: AS160078 Status: ISSUED Applied 3/31/2016 Approved: 4/18/2016 Issued: 4/18/2016 PC #: Inspector: Project Title: FASHIONPHILE T.I. INSTALL NEW CONCEALED PENDENTS Applicant: TOTAL FIRE PROTECTION, INC STE. 244 1611-AS. MELROSE DR. VISTA, CA 760-525-4329 Owner: PALOMAR B LC L L C C/O BIXBY LAND CO 2211 MICHELSON DR #500 IRVINE CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 438 0 438 0 about:blank 1/1 'U MATERIAL DATA SUBMITTAL Fashionphile 6359 Paseo Del Lago Carlsbad, CA 92011 Page * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee 13-19 Sprinkler Reliable F I FR56 Sprinkler 20-23 Sprinkler Reliable F I FR56 Sprinkler 24 Hanger Afcon Fig. 300 Ring Hanger 25 Hanger Afcon Fig 655 All Thread Rod 26-27 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. #244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohnc@gmail.com AS1 60078 6359 PASEO DEL LAGO DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL. ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (9 <~> 8 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications tIPS Naminall.D. WI. WI. (H20 Filled) PcW WtI[ift (21') WULIfI (241) WULIft (25') In; mm In; mm LbrIFt Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs Kg 1.080 1.330 1.75 70 1955 2234 232 25 274 2.0 2.60 70 887 1013 105 1W 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 251 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 16100 S. Lathrop Harvey, IL 60426 tqco/Rowconrn.I Qr flied 11350 Norcom Rd. Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27th Ave. . Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1800 S3-3 Submittal Data Sheet DynaThreadG Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Stamp Here Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- Specifications lIPS Nominal I.D. WI. WI. (1120 Riled) PcW Wts1Jlt (21') WUUft (241) WIsUft (25' In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1W 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114. 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 grooved, and plain-end fittings. (See American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, listing information). 1997. The engineered lightwall and standard wall family of products although they The internal surface of all black Fire have different names are the same in all respects with regard to strength, weight, Sprinkler pipe up to 4.5000" in diameter bundle count, listings and approvals. For example, shall be coated with Allied Tube & Dyna-Flow and Super Flo are the same product as Conduit Antibacterial Formula 'ABF". are Dyna Thread and Super 40. XL is manufactured (I) <e>(j) with Exterior galvanized coating. BIT is manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 2 S3 -4 tLfco /Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco* Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, In addition to the standards of any other authorities hav- ing junsdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data- Approvals: UL Usted and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17.2 bar) Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty Is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Are Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or Inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was Informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made In lieu of any and all other warranties. ex- ores or implied, including warranties of merchantability and fitness for a carticular curoose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made In contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. Page 1 of 10 JANUARY, 2008 'registered trademark of E. I. du Pont de (()) Nemours and Company or Its affiliates. TFPI7IO Page 2of 10 TFPI7I0 E A FIGURE 811 FIGURE 813 90° ELBOW 450 ELBOW NOMINAL DIMENSIONS FIGURES 811 & 813 Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0111) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0118) (25,4) (11,2) 0.81 (20,6) 0.64 (0,29) 86200 1.13 (28,7) 0.81 (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43)(33,3) (1610) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (3811) (0,79) (427) (23.9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) TABLE I Nominal Pipe Size Figure 813 ANSI A Approx. Inches Inches Weight Part ON (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0109) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 0N25 1.50 (38,1) 0.48 (0,21) 86280 1-1/4 1.75 0.73 86281 DN32 (44.5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 0N50 (57,1) (0.70) 2-1/2 2.89 2.70 DN65 (68,3) (49,3) (25,4) (1.22) 86782 TFPI7IO Page 3 of 10 FIGURE 812 900 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Inches Inches Is Is Inches Weight Lbs. Part Number ON (mm) (mm) (mm) (mm) (kg) 3/4 x 1/2 1.19 1.19 0.63 0.63 0.33 DN20x 16 (30,2) (30,2) (16,0) (16,0) (0115) 86342 I x1/2 1.25 1.38 0.56 0.81 0.44 86210 DN25 x 15 (31,8) (35,1) (14,2) (20.6) (0,20) I x3/4 1.38 1.44 0.69 0.88 0.53 DN25 x 20 (35.1) (36,6) (17,5) (22,4) (0,24) 86211 1-1/4x 1/2 1.31 1.50 0.63 0.94 0.64 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 86212 1-1/4x3/4 1.44 1.63 0.75 1.06 0.75 86213 0N32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-1/4x 1 1.56 1.68 0.88 1.00 0.77 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 86214 1i/2x3/4 1.50 135 0.75 1.19 0.95 86221 0N40 x 20 (38.1) (44,4) (19.0) (30,2) (0,43) 1-1/2x 1 1.63 1.81 0.88 1.13 0.99 86215 0N40 x 25 (41.4) (46.0) (22,4) (28,7) (0,45) 1-1/2x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40 x32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x314 1.63 1.94 0.88 1.38 1.39 86217 DN50x20 (41,4) (49,3) (22.4) (35,1) (0.63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DNSO x 25 (44,4) (52,3) (50,8) (33,3) (0,72) 2x1-112 2.00 2.19 1.25 1.44 1.67 86220 DN50 x 40 (50,8) (55,6) (31.8) (36,6) (0.76) 2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 DN65 x 50 (60.5) (66.8) (31.8) (47,8) (1.36) 86262 TABLE 2 NOMINAL DIMENSIONS FIGURE 812 TFPI7I0 Page 5 o 10 Approx. Weight Part Lbs. Number (kg) 0.18 72779 (0108) 0.26 72778 (0111) 0.44 72755 (0,20) 0.54 72754 (0,24) 0.71 72753 (0,32) 1.15 72752 (0,52) 2.29 72758 (1,04) T-1 13 I_Al N 1 _ JJiI I-F-- ': FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING Size Nominal Pipe Figure 814 Figure 818 A B Approx. A B ANSI Inches Inches Inches Weight Part Inches Inches DN (mm) (mm) Lbs. Number (mm) (mm) (kg) 1/2 1.13 0.56 0.33 86340 1.38 0.31 0N15 (28.7) (14,2) (0,15) (35,1) (79) 3/4 1.31 0.75 0.50 86341 1.63 0.56 0N20 (33,3) (19,0) (0.23) (41,4) (14,0) 1 1.50 0.81 0.85 86230 1.75 0.38 DN25 (38,1) (20,6) (0,38) (44,4) (9,7) 1-1/4 1.75 1.06 1.30 86231 2.00 0.56 DN32 (44,4) (26,9) (0,59) (50,8) (14,0) 1-1/2 1.94 1.19 1.63 86232 2.19 0.75 DN40 (49,3) (30,2) (0,74) (55,6) (19,0) 2 2.25 1.50 2.63 86233 2.63 1.13 DN50 (57,1) (38,1) (1119) (66,8) (28,7) 2-1/2 2.69 1.56 4.55 86234 3.00 0.75 DN65 (68,3) (39,6) (2,06) (76,2) (19,0) TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 TFPI7I0 Page 6of 10 Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 ANSI Inches A B C D E F Approx. Weight Part DN Inches Inches Inches inches Inches inches (mm) (mm) (mm) (mm) (mm) (mm) Lbs. Number (kg) 1-1/2 x 1-1/4 x 1/2 1.44 1.31 1.69 0.69 0.63 1.13 1.03 DN40 x 32 x 15 (36.6) (33.3) (42.9) (17.5) (16.0) (28.1) (0.47) 86257 1-1/2 x 1-1/4 x 3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 DN40x32x20 (38.1) (36.6) (44.5) (19.0) (19.0) (30.1) (0.50) 86258 1-1/2x 1-1/4x 1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 DN40 x 32 x 25 (41.4) (39.7) (46.0) (22.4) (22.4) (28.7) (0.59) 86259 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 0N40 x 32 x 50 (55.6) (54.1) (50.8) (36.6) (36.6) (57.1) (0.88) 86260 14/2 x 1-1/2 x 1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 DN40 x 40 x 15 (36.6) (36 (42.9) (17.5) (17.5) 86261.6) (28.7) (0.52) 14/2x14/2x3/4 1.50 1.50 1.75 0.75 0.75 1.19 1.23 DN40 x 40 x 20 (38.1) (38.1) (44.4) (19.0) (19.0) (30.1) (0.56) 86262 1-1/2 x 1-1/2 x 1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 DN40 x 40 x 25 (41.2) (41.2) (46.0) (22.4) (22,4) (28.7) (0.62) 86263 1-1/2x1-1/2x1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 _______ DN40 x40 x32 (46.0) (46.0) (47.6) (27.0) (27.0) (30.1) (0.68) 86264 1-1/2x1-1/2x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 DN40 x 40 x 50 (55.5) (55.5) (50.8) (36,6) (36.6) (31.7) (0.91) 86265 2x1 x2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 DNSO x 25 x 50 (57.2) (50.8) (57.2) (38.1) (33.3) (38.1) (0.99) 86266 2 x 1-1/4 x 2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 DN50 x 32 x 50 (57.2) (54.1) (57.2) (38.1) (36.6) (38.1) (1.05) 86267 2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 DN50 x 40 x 15 (38.1) (36.6) (47.8) (19.0) (17.5) (33.3) (0.68) 86268 2x1-112x3!4 1.63 1.50 1.94 0.88 0.75 1.38 1.61 DN50 x 40 x 20 (41.4) (38.1) (49.3) (22.4) (19.0) (35.0) (0,73) 86269 2 x 1-1/2 xl 1.75 1.63 2.00 1.00 0.88 1.31 1.65 DN50 x40 x 25 (44.5) (41.4) (50.8) (25.4) (22.4) (33.3) (0.75) 86270 2 x 1-1/2 x 1-1/2 2.06 1.94 2,19 1.31 1.19 1.44 2.03 0N50 x 40 x 40 (52.4) (49.2) (55.5) (33.3) (30.2) (36.6) 86272 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 DN50 x 40 x 50 (57.1) (55.5) (63.5) (38,1) (36.6) 138.11 (1.07) 86273 2x2x1/2 1.50 1.50 1.88 0.75 0.75 1.31 1.50 DNSO x 50 x 1 (38.1) (38.1) (47.8) (19.0) (19.0) (33.3) (0.68) 86222 2x2x314 1.63 1.63 1.94 0.88 0.88 1.38 1.67 86223 DN50 x 50 x 20 (41.4) (41,4) (46.3) (22.4) (22.4) (35.0) (0.76) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 DN50 x 50 x 25 (44.5) (44.5) (50.8) (25.4) (25.4) (33.3) (0.86) 86224 2x2x 1-1/4 1.88 1.88 2.13 1.13 1.13 1.44 2,05 DN50 x 50 x 32 (478) (47.8) (54.1) (28.7) (28.7) (36.6) (0.93) 86225 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 DNSO x 50 x 40 (50.8) (50.8) (55.6) (31.8) (31.8) (38.1) (0196) 86226 2x2x2-112 2.63 2.63 2.38 1.75 1.88 1.44 3.67 DN50x 50 x 65 (68.8) (66.8) (60.5) (44.5) (47.8) (36.6) (1.66) 86227 2-1/2 x 2 x 3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 DN65x 50x20 (44.5) (41.4) (58,7) (15.9) (22.4) (44.5) 1 (1.01) 1 86274 TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 Page 8 of 10 TFPI7IO Em:ft~l~ FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Size Figure 820 Figure 830 Figure 719 ANSI A Approx. A B Approx. Approx Inches Inches Weight Part Inches Inches Weight Part Ines Weight Part ON (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 112 0.88 0.15 72776 1.86 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0.06) (478) (20,6) (0,21) (23,9) (0,04) 3/4 1.00. 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 0N20 (25,4). (0,10) (50,8) (23,9) (0,30) (28,7) (0,08) 1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DN25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 DN32 (33,3) (0.24) (63,5) (26,9) (0,70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 DN40 (35,1) (0,31) (66.8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.95 72823 3.13 1.63 3.15 86279 .1.50 0.90 86297 DN50 (38,1) (0,43) _ (79,5) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 TFPI7IO Page 9 of 10 FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPUNG Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part ON (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 112x112 1.50 0.20 72751 - - - - - - - DN15 x 15 (38.1) (0.09) 1/2 x 1/2 2.00 0.27 72980 - - - - - - - DN15 x 15 (50.8) (0,12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (38,1) (0110) 3/4 x 3/4 2.00 0.31 73982 0N20 x 20 (50,8) (0,14) - - - - - 3/4 x 1/2 1.75 0.69 0.38 86772 DN20 x 15 - - - - - - (43,2) (17,5) (0,17) I x1/2 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25 x 15 - - - (26,9) (010) (42,9) (12,7) (0,17) I x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25 x 20 - - - (26,9) (0,08) (43,2) (12,7) (0,24) 1-114x1 1.19 0.31 72763 - - - - DN32x25 - - - (30,2) (014) 1-1/2 x 1.25 0.53 72757 - - - - DN40 x 25 - - (31,7) (0,24) 1-1/2x1-1/4 1.25 0.35 72764 - - - - DN40 x 32 - - - (31,7) (0110) 2 xl 1.38 0.75 72759 - - - - DN50 x 25 - - - (35,1) (0,34) 2x1-1/4 1.38 0.69 72761 - - - - DN5O x 32 - - - (35,1) (0,31) 2x1-1/2 1.38 0.62 72775 - - - - DN50 x 40 - - - (35,1) (0.28) TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 01 Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM 8-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet TFP1895 for aid in selecting LlstlnglApproval inrormation proper gasket) General Description twee/'Ffre & Building rnducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap The Fugure40-5 Strap Is aneconomicalaltemative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap maybe used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as wallas withtheapplicable standards of the National Fire Protection Association, in addition tothe standards ofany 01herauthorities ha vingjurisdiction. Failure to do so may impair the palformance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturershouldbecontacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL FM, ULC. and VdS; See Fire Protection Submittal Sheet for exact Listing/Approval information. Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity,figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and intemationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their tire protection system and devices in accordance with the applicablestandards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractoror product manufacturer should be contacted relative to any questions. Any impairment must be Immediately corrected. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid brand property installed and maintained under normal use and service. This warranty will expireten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwfthTyco Fire Products orfor products and componentswhlch have been subject to misuse, improperinstallation.corrosion, orwhich have not been installed, maintained, modified or repaired in acconlancewith applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any otherAuthoritiesHaving Jurisdiction. Materials found byTyco Fire Products tobedefectiveshallbeeltherrepairedorreplaced,at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit,anyotherobligationinconnectionwith the sale of products or parts of products. Tyco Fire Productsshaflnotberesponsib!eforsprinklersystem deslgnerrorsorinaocurateorincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES,INCLUDINGBUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERIYCOFIREPROOLJCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND INNO EVEIff SHALLTYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. 11NI WAFa%4NIYNIMAfELVLIWOF ANYAND ALL O1ND WAND4N7NDEOR IMPLIED, INCLUDING WARRANTIES OF MERCILINTARIIJTY AND FITh'ESS FOR A Page 1 of 2 September 2004 TFPI 720 Pipe Nominal Dimensions Hole Net Size Size WI. A B C D Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11/4° X 1/211 2.00 1.50 3.50 1.20 1/io 0.84 50.8 38.1 88.9 30.5 1 30.2 0.4 11/4° 2.00 1.50 3.50 1.20 1/ie 0.88 50.8 38.1 88.9 30.5 30.2 0.4 1V4" X 1 2.31 1.68 3.50 1.20 13'is 1.13 58.7 42.7 88.9 30.5 30.2 0.5 1V2' X V2° 2.12 1.62 3.50 1.32 13/is 0.84 53.8 41.1 88.9 33.5 30.2 0.4 lh/2U x 3/4 2.12 1.62 3.50 1.32 1/I6 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/2° X ., 2.43 1.80 3.50 1.32 13M 1.13 61.7 45.7 88.9 33.5 30.2 0.5 21 X 'Ie° 2.36 1.86 3.74 1.55 13AG 0.88 .59.9 47.2 95.0 39.4 30.2 0.4 20 x 3/lI 2.38 1.86 3.74 1.55 1/16 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2x i° 2.67 2.04 3.74 1.55 Wis 1.16 67.8 51.8 95.0 39.4 30.2 0.5 2/2° X 1/2U 2.61 2.11 4.25 1.80 1/I6 0.90 66.3 53.6 108.01 45.7 30.2 1 0.4 211? X3/4° 2.61 2.11 4.25 1.80 lYie 0.99 66.3 53.6 108.0 45.7 30.2 0.4 21/2° x 10 2.92 2.29 4.25 1.80 Wis 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 1'/4°X 1° 8 11/2°X 1 6 2°xl° 6 21/2U x 11 4 The friction loss for these outlets is specified In equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFP172O Figure 40.5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. 12 General Notes: it Is the DesIgners responsibility to select products suitable for the intended service and to ensure IS that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (IH-1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified lobe compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Bulletin 013 Rev. L Re - ® Models Fl Series Standard Response iable Standard Spray Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pendent/F1/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/Fl/F2/FP Approval Organizations Underwriters Laboratories Inc. and certified for Canada (cULus) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH EC Certificate: 0786-CPD-40237 (RA1314) 0786-C PD-40253 (RA 1 325) 0786-CPD-40254 (RA1 375) UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. YjU Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed PendentiF1lF2 Recessed Recessed XLH Upright Horizontal Sidewall PendentlFP XLH Pendent XLH Recessed Pendent F1/172 Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 0 13FG04 Model F142, F1XLH Upright Technical data: Models Discharge Coefficient Response Thread Max. Working Mm. Working Temperature Finish Size Pressure Pressure Rating F156 K5.6 1/2" NPT See See F142 1XLH 4.2 Standard (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" Ratings" Table L F K F128 K2.8 Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or or coated with PTFE Adhesive Glass CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Size 1 Nominal K Factor _____________ Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US I Metric Uriht I Pendent Standard-UprIght (SSU) and ,endent Deflectors Marked to Indicate Position 1/2" (15mm) " 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1.2.3.4.5 RA1325(2X3)(5X°) I RA1314 25 7/16" (10mm) 1/2" NPT (R1/2) 4.2 I 60 2.25" (57mm) 1 RA1323(2X6) I RA1313 3/8 (10mm)— 1/2" NPT (R1/2) 2.8 I 40 2.25" (57mm) 1 RA132106) I RA1311 Conventional-Install in Upright or Pendent Position 15mm (1) I 1/2" NPT (R1/2) I 5.6 I 80 I 57mm I 3. 4. 5 I RA13755 Refer to Bulletin 024 for Special Response Sprinklers (Fl S5-56) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM Approved sprinkler. (4)_____ (5) Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. Electroless Nickel PTFE (Teflon)* Plated - UL listed Corrosion Resistant Upright Pendent Conventional Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers' Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) RA13142 7/16" (10mm) 1/2" NPT (131/2) 4.2 60 2.25" (57mm) RA1313'2 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA13112 Refer to escutcheon data table for approvals & dimensions Electroless Nickel PTFE (Teflon)* Plated - cULus listed Corrosion Resistant 1 1102 Hi — (57.1w.,) r1, flAHLHiLA 1010 ff SPIMMIEV 'I F & RYflW I ID rAOL Of COLM HI,IDHy F, ,jmn - - 1L AT RE= - ff Il. AT H10HM OLS - IWcUdlV - I flDflI 1i2712.1I,,,,) I _________ _______ Ar IlUIdIDI 10 • 7/81222,1,,) Ar IHH4l8S AEU - laT.lJr.,,) 10 mEHI AT FSUIHAI REOL - I-I/a 21414,,,, AT 1010W - RECESSED PENDENT win OR F2 ESCUTCHEON 'S'HWIIHI LOT Ill AH14D VW F1 ISMINCHM Model F156, F142, F1XLH & F128 Fl or F2 *DuPont Registered Trademark ,•x I/2R60UC671 2 AAW HA. (627am) HOLE 10 CEIlING 2 5/I6 DLI. (5147—) Cup FACE OF F7ThL'C ID lICE OF CEIlING OWWRON IT W.XWAUU RECESS - I-I/a7J&14aJ 2 URAMUM RLS - 1125.4w,,) A r W1MIUII RECESS - P/I87I4J..,,j I AT MIMMUM RECESS - 1125.4w,,) F7- _ RECESSED PENDENT W/FP ESCUTCHEON o, SPRINIELER NOT FM AOUED 4DM FP 13CUTCHM Model F156, F142, F1XLH & F128 FP 3. Vertical Sidewall Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Installation Data: Nominal Orifice I Thread Size I Nominal K Factor Sprinkler Height Approval Organizations I Sprinkler I Identification I I I i I US I I Metric i Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 8.0 2.25" (57mm) 1, 2, 3 RA1385(1X2)(3)(4) "LPC Approval is pendent only, 57°C through 141°C ratings. (2)cULus Listed corrosion resistant (Polyester coated) sprinkler. (3)cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. '4TElectroless Nickel PTFE (Teflone)* Plated - cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench FACE OF FITTING To FACE OF CEIUNG DIMENSION Fl ESCtflCHEGAA AT MAXIMUM RECESS 1725.4mm) AT MINIMUM RECESS 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS - 3/4719mm] AT MINIMUM RECESS - 3/879.5mm] r2 114" HOLE ON. (5 7.2mm] X 1/2 REDUCER - 2 27/32 DIA (72.2mm) I () 4-12 (101.6mm-304.8mm] CETUNG TO DEFLECTOR TURN COLLAR UNTiL -' TIGHT AGAINST SPRINKLER I Fl ESCUTCHEON WRENCH BOSS. .7/4719mm) ADJUSTMENT 1/2712.7mm) ADJUSTMENT Fl ESCUTCHEON AT MAXIMUM RECESS - 1-3/8734.9mm) AT MINIMUM RECESS - 2-1/16752.4mm) F2 ESCUTCHEON AT MAXIMUM RECESS - 1-5/8741.3mm) AT MINIMUM RECESS 2-1/16752.4mm1 RECESSED HSW W/FI OR F2 ESCUTCHEON (I) FM APPROVED FOR 4 - 6 (101.6MM - 152.4MM) CEILING TO DEFLECTOR. Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. FM and cULus permits use with Fl or F2 escutcheons for Installation Data:Horizontal Sidewall "Light Hazard" only. Nominal K Factor __________________ Sprinkler Height Approval Organizations Sprinkler Nominal Orifice Thread Size Identification US I Metric Light Hazard I Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1335(1X2)(3X4) 11cULus Listed corrosion resistant (Polyester coated) sprinkler. cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (TeflonB)* Plated - cULus listed Corrosion Resistant *DuPont Registered Trademark 4. Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & F128 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and spnnkJer type are in ac- cordance with the latest published standards of the National Are Protection Association or the approving Authority Having Jurisdic- tion Installation. Installaftri Model F156, F142, F1XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3A inch (19mm). The Model Fl, F2, and FP Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight 1/2" NFl (R112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating: - Specify when ordering - Model F156 Pendent Sprinkler Sprinkler Finish Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (1) (') SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only. Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non-operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High" 141 286 225°F (107°C) Blue Extra High' 182 360 300°F (149°C) Mauve Ultra Hi-gh (1)(2) 1 260 1 500 1 475°F (246°C) I Black Not available for recessed Sprinklers. (2) cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finish(') Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (6X7)(9) White Painted Special Application Finishes Sprinkler Escutcheon Electroless Nickel PTFE(refion°)°) Electroless Nickel PTFE (Teflon®)* Bright Brass(2) Bright Brass Black Plated Black Plated Black Paint(3X9) Black Paint Off White (3X9) Off White Chrome Dull Chrome Dull Lead Plated(3X4)(8) Wax Coated(3X4)(5X8) Wax Over Lead(3X4X5X8) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. 200°F (93°C) maximum. UL and ULC listed only. (4) 155°F to 200°F (68°C to 93°C) ratings only. 5 286°F(141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). cULus listed "corrosion resistant" applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1321(Uphght), RA1335 (HSW), RA1385(VSYv and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approved finish as "Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. FM Approved finish applies only to SIN number RA1335 & RA1385. LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. '°cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323, RA1313 ,RA1321, RA1311, RA1385 and RA1335 *DuPont Registered Trademark 5. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections 'Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled 1%1MJ13bJ (800) 431-1588 Sales Offices w Paper (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 04/15 PIN 9999970299 Model G5-80, Model G5-56, Model G542, Model G5-28 Quick Response Concealed Automatic Sprinkler Bulletin 034 Rev. D 11abile UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4 (19mm) Adjustment Features Cover plate attachment (Plain or Perforated) with 3A" (19mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies G5-42 - Light Hazard Occupancies G5-28 - Light Hazard Occupancies 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) G5-56 & G5-28 only. See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response G5-56 - Light Hazard and Ordinary Hazard Occupancies vds SchadenverhUtung GmbH - Standard Response EC-Certificate of Conformity 0832-CPD-2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. it provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 34" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Installation Do not install the G5-80, G5-56, G5-42 and 135-28 in ceilings which have positive pressure in the space above. Cut a 2" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drwe which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER! CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model 135-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons, and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Sprinkler Model Nominal Orifice Flat Cover Plate Plain or Perforated Flat Cover Plate Assembly Finish Inlet Type Cover Plate Finishes(l) Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome " Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification I Sprinkler I I Cover Max. Ambient I I I Temp. Ordinary 1650F/740C I 1350F1570C I 100°F/380C I Intermediate I 212017/1000C 1650F/740C 1500F/660C U I adi iaOVg. Model FC SDrinkler UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV 2. Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Metric A Approvals Sprinkler Identification (SIN) US G5-80 Non Adjustable 3/4" (19mm) 17% (15mm) 8.0 115 34" NPT (R3%) 1 RA3412 G5-56 Non Adjustable 3/4" (19mm) i/a" (15mm) 5.6 80 ½' NPT (RIM 1,2,3,4.5 RA3415 G5-42 Non Adjustable 3/4" (19mm) /io" (10mm) 4.2 60 ½' NPT (R½) 1 RA3413 G5-28 Non Adjustable 34" (19mm) 3%' (10mm) 2.8 1 40 ½" NPT (R'/2) 1,2 RA3411 For VdS Approval, temperature rating sprinkler 1650F/740c and cover plate 1350171570C only! x 7/2" REDUCING 1" TEE OR ELBOW TEE OR ELBOW x 3/4" REDUCING G5-80 ONLY II' (66.55mm) 4" (58.42mm) 014 - HOLE IN CEILING CUP I I I I I (19.05mm) MAX. COVER ADJUSTMENT ___ FACE OF FITTING TO FACE OF CEILING 1/4 MIN DIMENSION TO CEILING ________ . 2-7/4" (57 75mm) MAX. (6.35 I _/ 1" (25.4mm) MAX. DROPPED DEFLECTOR ____________ ________ _________ _____ k FL4r COVER PLATE .,./ _/ (84.2 7mmJDIA .4 ' ' (4.96mm) —CEILING ASSEMBLY SPRINKLER O34FG9iO COVER PLATE. 3/4"[19.05mm]ADJUSTMENT oiice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS I" x 7/2" REDUCING TEE OR ELBOW 11I]L:-_rTTJ RELIABLE P/N 6999997900 Ii X " BRASS NIPPLE EXT. 4" (58.42mm) 014 CUP " (19.05mm) MAX. COVER ADJUSTMENT ii . 7/4' (6.35mm) Al/N. TO CEILING 7" (25.4mm) MAX. DROPPED DEFLECTOR 10 CEIUNG - 2k" (66.55mm) HOLE IN CEILING 3-1/76" (77.72mm) MAX. FACE OF F7T11NC 10 FACE OF CEILING DIMENSION 2-7/4"(57.15mm) MAX. FACE OF NIPPLE EX1 70 FACE OF CEILING DIMENSION /7 FLAT COVER PLATE 4' (84.27mm) 01k ,' (4.96mm) SPRINKLER Offum COVER PLATE. 3/4"[19.05mm]ADJUSTMENT Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler. For RETROFIT installations, per NFPA 13(2010) section 8.15.19.4, which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". Do not exceed 8-18 ft-lbs of torque during installation. 3. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices ' Paper Reliabil (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/14 P/N 9999970421 IMPERIAL MAX REC. LOAD LBS. METRIC' PIPE PiPe ROD 1/2 IS 400 10 314 318 !3W8 400 20 To- 400 25 10 11/4 afa 400 -_32 - _!!L 11/2 318 400 40 10 2 318 400 50 10 21/2 318 600 65 io 600 80 10 3112 318 600 10 3/8 1000 100 in 5 112 1250 125 12 6 112 1250 150 12 8 lj2 1250 2W 12 Order Part #300m Note: 1/2° Ring Hanger not <FM> approved 8 300 RING HANGER zS A)US I thru 4 Inch pipe 112 and 314 inch pipe 5 thru 8 Inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mil. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H-171(Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru 4 inch: * Offset edge for EASY pipe insertion. 1 thru8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru3 inch: * UL listed to accept AFCON#3 10 Surge Restrainer. Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index 02/01 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. FOR SERVICE LOAD LBS. TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in linch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. 2/00 8 reft.4 Nut Driwr (kern #100) Weight Model Shk Lgth Shk Tha Box Qty (per 100) Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 1 2 1/4 100 6.50 1000 23 GST 300 1 3 1/4 100 7.50 1000 24 GST 600 1 6 1/4 50 9.00 500 WOOD - Sammys i #14 (item#100.bladc) Sammys 114", 318" rod Minimum 2" imbedment into base For vertical use. material for NFPA13compliance Install in canter ofiowerface. Notieasthan 2" nominal width (1112") oist I Truss jas manufacturer for ed Installation point. Fig may be required us ff27 and #O6 Tools available on page 9. q Wood Joist Use #14 Nut Drner (Item #100) Appromis _______ Item # Model _________ Shk 14th Shk Din ______ FM Test Load, lb. ULlest Load lb. UIJFM Pipe Size Actual Pullout Box Qty 10 GST.75 3/4 1/4 564#-6 Ply 100 NFPA 11 GST 10 1 1/4 7/16 OSR 210# - 670ff - 3/4" Ply 100 UL.FM.NFPA 12 GST 20 2 1/4 9404 850ff 3/4-21/2 1760ff - Fir 100 UL'NtI'A * 27 GST25-380 21/2 3/8 1500ff 4 2113ff-Fir 50 UL•FM'NFPA 13 GST30 3 1/4 1475ff 1500ff 3/4-4 2060ff- Fir 100 NEPA 403 GST40 4 1/4 2180ff- Fir 50 NPPA 14 GST60 6 1/4 2230ff-Fir 50 HETITIMM r5e#14SW Model Shk Lgth Shk Dia Nut Driwr (Item #101) Weight Actual Pullout Box Qty (per 1O) Case Qty S GST2 2 1/4 1760ff-Fir 50 7.00 500 * 06 GST 2.5-380 2 1/2 3/8 2113# - Fir 50 10.00 500 15 CST3 3 1/4 2275ff-Fir 50 10.50 500 16 GST4 4 1/4 2180ff-Fir 50 10.60 500 17 GST6 6 1/4 2230ff-Fir 50 10.95 500 i #I4SW (Item #1O1.red) Sldcwinders& Sammys 112" rod --..- - - -- - - -iF-. Wood Flooring Double Sheetrock Ceiling Page 4 Note: Screw must be installed with appropriate nut driwar to comply with warranty #14 (Item#IOO.Ci&*) Sammys 114", 318" red A Prestressed Concrete (:D Page 5 WOOD —Sidewinders I Use #I4SW Nut I)riwr (Item #101) Ite Model Shk Lgth1 Shk Dia Actual Shear/Pullout Box Case QtyI I Weight I (per 100) I I I 4016 ISWG100I 1 1/4 I 100 I 7.50 I 1000 I I 300 ISWG200I 2 114 17254-Fir 100 8.00 1000 WSII11.1RIIm1umkL.Jllms1rnm1. Use#14SW Nut Driwr (Item #101) Approals Item # ___________________ I Model Shk Lgth Shk Dia UL Test Load lb. IJIJFM Pipe Size Actual Shear/Pullout Box Qty Weight (per 100) 18 1SWG10 1 1/4 100 6.00 UL•NPPA 19 JSWG20 2 1/4 12504 3 17250 - Fir 100 7.00 LIL.NFPA * 26 Iswc 25-380 21/2 3/8 1 15004 4 22494- Fir 50 10.25 25 ISWG30 3 1/4 50 1 8.50 Not less than 2" nominal width (1112") up ________ to 3112" pipe; not lass than 3" nominal r-i w1dth4"&5'pipe FloorJoist r ___ TJI Joist I Truss Consult miss manufacturarfor recommended lnstallalion point. *pre.drilljng may be required for item #26. Tools available on page 9. di SHEETROCK Minimum 2112" from bottom for branch lines. Minimum 3" from bottom for main lines. Exception: This requirement shall not apply to 2" orthlcker nailing stflpa resting on top of steel beams. - Toggle Use #14 Nut Driver (Item #100) Item# Model I IshkthI I Shk Dia Actual Pullout Box Qty Weight Case Qty (per 100) 71 SST300 3 1/4 4501/ Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock IUse #14 Nut Driwr(ltein#100) Item# Model IShkLgth Shk Dia Actual Pullout Pkg Qty Weight Case Qty (per 100) 70 SST3O 3 1/4 450# Lath & Plaster 50 12.00 500 40411 2 Layers 5/8 Rock Note: Screws most be installed with appmp,fatenuld*srmcompfr with warranty it #I4SW (ltem#101.qed) Sldewlnders& Sammysl!2"rod