HomeMy WebLinkAbout6125 PASEO DEL NORTE; 100; FPC2016-0029; PermitPERMIT REPORT (rcc ity of Carlsbad Print Date: 02/15/2024 Job Address: 6125 PASEO DEL NORTE, # 100, Permit Type: FIRE-Construction Commercial Parcel U: Valuation: $0.00 Occupancy Group: - #of Dwelling Units: Bedrooms: Bathrooms: CARLSBAD, CA 92011-1117 Work Class: Fire Sprinklers Track U: Lot #: Project U: Plan U: Construction Type: Orig. Plan Check #: Plan Check U: Permit No: FPC2016-0029 Status: Closed - Finaled Applied: 12/07/2016 Issued: 12/15/2016 Finaled Close Out: 03/10/2021 Final Inspection: INSPECTOR: Wong, Cindy Fieri, Dominic Project Title: Description: PASEO DEL NORTE LIC -SPRINKLER TI FPContractor: PARAMOUNT FIRE SYSTEMS INC P0 BOX 713194 SANTEE, CA 92072-3194 (619) 562-6247 FEE AMOUNT FIRE NFPA 13 or 13R System > 100 heads $634.00 FIRE Reinspection (per inspection) $187.00 FIRE Reinspection (per inspection) $187.00 Total Fees: $1,008.00 Total Payments To Date: $1,008.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov fFt2oL-.ck%15l iizimowi t F/RE S YS TEMS, INC. PASEO DEL NORTE LLC Medical Office Building 6125 Paseo Del Norte Carlsbad, CA, 92011 AUTOMATIC WET FIRE SPRINKLER SYSTEM Material Submittal Table of Contents MATERIAL Sprinkler Heads Valves & Gauge Grooved Fittings Steel Pipe & Fittings Hangers & Seismic Assemblies Electrical & Accessories Fire-Stopping Page# 01-04 05-06 07-17 18-28 29-39 40-44 45-52 P.O. Box 713194 Santee, CA 92072 (619)562-6247 fax (619) 562-6273 j&xc)- kiV tq. a Fire Protection Products Worldwide Contacts www.tyco-fire.com Series TY-FRB, 5.6 K-factor UpknÜht, Pendent, and Recessed Pendent Sprinklers Qüick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quiôk response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- elation of sprinkler systems and corn- :pthients. Improper, handling and installation can permanently dam- 'age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2 NPT TY323 ......Pendent 5.6K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar"2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6 * 7/16" I (11,1mm) (50,8 mm) : I NOMINAL __ __ N c J MAKE-IN _____ - 2" (50,8 mm) __________ _____________ (349 mm) 1-.-1__1 _______ ______ WR 13/8 1/2" NPT** DEFLECTOR * 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY 60 END "A-) FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 6 t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP172 1 Page 3 of 4• Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8° (15,9 mm) ____ FLUSH 3/8±5/16" (9,5±7,9 mm) T MOUNTING t SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8° (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY.FRB RECESSED PENDENT SPRINKLER ASSEMBLY (17323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8° DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4 DIA. FITTING (57,2 mm) 5/16±1/4° (7,9±6,4 mm) 1/2° (12,7 mm) FLUSH MOUNTIN>/Vol 1/8" j SURFACE ,2 mm) CLOSURE SERIES MOUNTING 1-3/811 (34,9 mm) TYFRB PLATE 7/8° (22,2 mm) FIGURE 5 SERIES 7Y -FRB RECESSED PENDENT SPRINKLER ASSEMBLY (17323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 'TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I I SPRINKLER TEMPERATURE FINISH -L RATINGS SIN 1 NATURAL BRASS I 370 I 5.6K UPRIGHT (112 NPT) TY313 3 PURE WHITE (RAL9010r 155 155-F (68 POLYESTER 371 5.6K PENDENT (1/2 NFl) TY323 4 SIGNAL WHITE (RAL9003) POLYESTER Use suffix -r for ISO 1-1 connection; 9 CHROME PLATED for example. 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135 F(57 C) C) 175 175*F 79* 200 200 F (93 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (PIN). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify finish, P/N (specify Specify: Style 20 Recessed Escutch- eon with (specify finish, PIN (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 286 286F (141°C) Fire GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright 02014 Tyco Fire Products, LP. All rights reserved. t ca TEFLON is trademark of The DuPont Corporation. Protection Products - e- Dimensions - Weights Size A B C wt. Lbs. W' 2.05 2.60 2.09 .66 3A" 2.36 2.70 2.24 .83 2.68 3.50 2.46 1.50 1W 3.08 3.85 2.85 2.13 1W' 3.46 4.30 3.22 3.06 4.00 1 5.10 3.43 4.88 Le k Globe Valves lAux Drain Soft Seat Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Description The Central Model F15 Soft Seat Bronze Globe Valves are designed for general service as shut-off, throttling, or drain valves. The Central Model F15 Soft Seat Bronze Globe Valves provide positive shut-off under normal operating conditions. They are recommended for water service only. The Central Model F15 Soft Seat Bronze Globe Valves are of cast bronze construction strictly in accordance with ASTM B-62 specifications 85-5-5-5 for superior corrosion resistance. The hand wheel is manufactured from cast iron materials to meet or exceed the requirements of Underwriters Laboratories, Inc., Factory Mutual, The American Water Works Association C-509 and ASTM A-126, Class B Standards. The Central Model F15 Soft Seat Bronze Globe Valves are rated with cold water at 200 psi, non-shock for cold water service, and are tested twice, air under water for consistent quality. The Central Model F15 Soft Seat Bronze Globe Valves have a soft rubber seat for tight shut-off under all operating conditions. (Mfg. Source: Non-Domestic) Bronze Globe Valves Page 28 No. 27.1.0 Central Sprink No. 4-5.0 Bill 6 f Materials Item Description Material Specification 1 Body Bronze ASTM B-62 2 Bonnet Bronze ASTM B-62 3 Stem Brass Rod ASTM B-16 4 Disc Holder Brass Rod ASTM B-16 5 Seat Disc NBR Commercial 6 Disc Holder Nut Brass Rod ASTM B-16 7 Disc Nut Brass Rod ASTM B-16 8 Packing Nut Brass Rod ASTM B-16 9 Packing Gland Brass Rod ASTM B-16 10 Packing PTFE Commercial 11 Hand wheel Cast Iron ASTM A-126-B 12 Ident. Plate Aluminum ASTM B-209 13 I Wheel Nut Brass Rod ASTM B-16 fl Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model number, style, orifice size, temperature rating, type of finish and sprinkler wrench. Availability and Service: Central sprinklers, valves, accessories, and other products are available throughout the U.S. and Canada; and internationally through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company or call (215) 362- 0700 for the distributor nearest you. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. Patents: Patents are pending. Conversion Table: 1 inch = 25.400 mm 1 foot = 0.3048 m 1 pound = 0.4536 kg 1 foot pound = 1.36 Nm I psi = 6.895 kpa = 0.0689 bar = 0.0703 kg/cm2 I U.S. gallon = 3.785 dm3 = 3.785 liters Conversions are approximate. CENTRAL '"REENNOW, Central Sprinkler Company 451 N. Cannon Avenue, Lansdale, PA 19446 © 1991 Central Sprinkler Company Phone (215) 362-0700 Printed in U.S.A. FAX F625385 F15.0 FireLock® Fittings FireLock6 products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. 11 MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Red Enamel in EMEA-l. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location - Date Approved Date___________________________________ www.victaulic.com VICTAUUC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. C 2010 VICTAUUC COMPANY. ALL RIGHTS RESERVED. REV_I \4taulicr 10.03_i 'IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS Fire Lock® Fittings DIMENSIONS I.0 toE1 NO. 001 10.03 to I Cto fe- & to E) NO. 003 NO. 002 NM OOS U, .p. •, . . ... Nominal Actu Approx. U, . Straight U,. Tee . UI,!. Inc Lbs nn), kg Ll- 32 42.4 - - - - - 21 0.1 - 1 ½ 1900 - - - - - 0.82 0.4 40 48.3 - - - - . - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 - 60.3 70 0.8 51 0.8 70 1.1 22 0.3 - 2½ 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22. 03 76.1 mm 3.000 3.00 3.30 2.25 2.4 76.1 76 13 57 1.1 - - - - 3 3300 338 4.0 2.50 - 3.1 338 53 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 03 4.250 4.00 5.7 3.00 5.1 108mm 4.00 73 108.0 102 2.6 76 2.3 - 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 - - 100 1143 102 3.0 76 25 102 3.9 25 1.1 5363 4.88 12.6 3.25 83 4.88 15.7 1.00 4.1 5 125 141.3 124 5.7 83 3.8 124 7.1 - 25 1.9 6.250 530 12.6 3.50 9.2 530 17.9 159mm 158.8 140 5.7 89 4.2 140 8.0 - - 6 11.7 5.9 6.625 530 18.3 3.50 550 22.7 1.00 . 150 1683 1 140 83 89 5.3 140 - 103 25. 2.7 8.625 6.81 4.25 6.94 38.7 1.13 8 20.4 12.7 200 219.1 173 11.6 108 93 176 17.6 29 5.8 - www.victaulic.com \JtauIicr VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03_2 REV-1 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 -41 FireLock® Fittings FLOW DATA t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVJ ,k4tauIicr 1O.03_3 - . ... ... .. GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009V/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaijlic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.03 1539 REV I UPDATED 22010 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 \4taulocr ;fr see notes on page 4 FireLock® Rigid Coupling N 5LPCandVdSApr'oned. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) FireLock® Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire protection systems. Vic-PIusTM Gasket System: In North America, Victaulic® offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The VicPlusTM System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. PATENTED C et i ".!?.! LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure — psi Related Working Pressure — psi Related Working Pressure — psi 5 10,40 BIT OF Dl EF PA-3 175 J 175 175 EL IV.-2 El 114-2 EZ 4-6 FF j4 GAL-71¼-2 MLT 1 V.a —2 MF 1'4-4 300 j N/A j N/A MT STF Steady IF WLS XL P/a-2 300 N/A N/A 1'A-4 350 ] 350 350 300 N/A N/A 116-4 N/A N/A 300 5-8 300 300 300 3008 N/A 300 116-2 N/A N/A 300 116-2 300 300 N/A N/A N/A 300 N/A N/A 1 300 3-8 N/A N/A 300 116-4 3OOO 300 I N/A 300 N/A 175 300 N/A 114-2 300 300 N/A 11/4 —2 300 300 300 N/A N/A 1 /4 —3 300 300 300 1Y-4 175@ FM approved for service in 116 —4' pipe. 8 UL Listed for service up to 4' pipe only. @ UL Listed for service up to 3' only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com vicTAulic IS A REGISTERED TRADEMARK OF V1CTAUUC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I . ,. .. 4 hitauhcr 10.02.I IPS CARBON STEEL PIPE- FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) Size Max. Work ax. End Allo Pipe Wi I .Wgt. Each Pressure § *ddE 1¼ 1.660 350 755 0.05 2-~x2-%.21/.4.50 2.75 1.88 1.2 32 42.4 2413 3370 1.2 70 114 148 0.5 1½ 1.900 350 990 0.05 3.00 475 1.88 1.2 40 483 2413 4415 1.2 2-%X2V4 76 121 148 0.5 2.375 350 1550 0.07 2-~x2½ 3.50 5.25 1.88 1.6 2 50 60.3 2413 6900. 17 89 133 148 0.7 2.875 350 2270 0.07 5.75 1.88 1.9 216 65 73.0 2413 10110 1.7 2-%x2164.00 102 146 148 .09 3.000 350 2475 0.07 2-4x2½ . 4.13 5.75 1.88 1.9 76.1 mm 76.1 2413 11010 17 lOS 146 148 0.9 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 3 80 88.9 2413 14985 1.7 2-%x2½ 118 156 148 1.0 4 4.500 350 5565 0.16 2-~x2½ 5.75 US 2.13 3.1 100 1143 2413 24770 4.1 146 184 54 1.4 4.250 300 4255 0.16 2-x2½ 5.63 7.25 2.13 3.1 108.0mm 108.0 2068 18940 4.1 143 184 54 1.4 5.563 300 7290 0.16 2-½x3 6.88 9.00 2.13 45 5 125 1413 2068 32445 4.1 175 229 54 2.0 5.250 300 6495 0.16 2-½x2M 6.63 9.00 2.13 4.5 133.0 mm 133.0 2068 28900 4.1 168 229 54 2.0 139.7mm 5.500 300 7125 0.16 2-½x 214 6.88 9.00 2.13 4.8 139.7 2068 31715 4.1 175 229 54 2.2 6.625 300 10340 0.16 2-½x3 8.00 10.00 2.13 5.0 6 150 168.3 2068 46020 4.1 203 254 53 2.3 6.250 300 9200 0.16 2- ½x 2% 7.63 10.00 2.13 5.5 159.0mm 159.0 2068 40955 4.1 194 254 .54 25 6.500 300 9955 0.16 2-½x3 8.15 10.00 2.13 5.5 165.1 mm 165.1 2068 44295 4.1 207 254 54 2.5 8.625 300 17525 0.19 2-%x4¼ 1050 13.14 2.63 11.3 8 200 219.1 2068 78000 4.8 267 334 67 5.1 Working Pressure and End Load are total, from all Internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 128ar/175 psi. DIMENSIONS It *10 "M , ~ - - I àIS !•j Rated for wet and dry sprinkler systems at 350 psi/2413 kPa for 1 16- 4732 - 100 mm sizes and 300 psi /2068 kPa for 414 - 87108 -200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 Is rigid and does not accommodate expansion, contraction or angular deflection. www.victaulic.com JtauIicr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUIJC COMPANY. © 2006 ViCTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02_2 REV-1 . . IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-Plus' Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plus'" Gasket System, requiring no field lubrication for most installation conditions. Grade "L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal° Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/-400C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-.180C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. xOA-c—ta U —1i e REV-1 10.60_3 - FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. I IlIIIIIIlIlIlIIflflIftlI 111111 WCAS-697KR4 For complete contact information, visit www.victaulic.com \JtauIicr 10.02 1538 REV I UPDATED 912006 vICTAULIc IS REGISTERED TRADEMARK OF vlcTAuuc COMPANY. 0 2006 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02 Standard Flexible Coupling STYLE 77 ® ILPCB1 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS I Style 77 couplings are designed with cross-ribbed construction to provide a strong component for pressure piping systems. Sizes V4 - 12720-300 mm are two-piece housings. For 14— 247350-600 mm sizes, Victaulic offers the Advanced Groove System (AGS) line of products. Request publication 20.03 for information on the flexible Style W77 AGS coupling. All sizes are provided with plated bolts and nuts. Galvanized and stainless steel housings are also available. Independent testing has shown the Style 77 coupling to be an effective stress relief and vibration attenuation device providing performance superior to braided steel and elastomeric arch-type connectors when used in close proximity to the source of vibration. Refer to 26.04 for vibration information. Independent testing has shown that Victaulic Style 77 flexible couplings provide exceptional functionality during and after earthquake conditions. Refer to 26.12 for further information. Exaggerated for for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. Optional: Hot dipped galvanized and others. Coupling Gasket: (specify choice*)t Grade "E" EPDM (All other sizes) EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +860F/+300C and hot i-180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Optional: Type 316 stainless steel, Grade B-8M, Class 2. f Supplemental lubricant is recommended for services installed at or continuously operating below 0°F/-18°C. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date________________________________ www.victaulic.com . - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REVJI 06.04_I n II L lop- j, 11,10 - 14 - 12' SIZES IPS CARBON STEEL PIPE - GROOVED COUPLINGS 06.04 Standard Flexible Coupling STYLE 77 DIMENSIONS Actuai D,fl,cl. 1,. 1,1 No - Size Dimensions - Inches/.m Wgt. Each Diarneter Inches V4 1.050 psi 1,3M Pipe 1,0Ft. inches 2-%x2 20 26.7 6900 3850 0-1.6 - 60 54 102 44 05 1 1.315 1,000 1,360 0-0.06 . 2 -43. 037 2-%x2 2.38 4.12 1.75 1.2 25 33.4 6900 6050 0-1.6 48 61 105 44 03 1% 1.660 1,000 2.160 0-0.06 2' 1 - 0 0.45 2 'i 2½ 2.65 5.00 1.88 2.0 32 422 6900 9610 0-1.6 38 67 1.7 48 0.9 11/2 1.900 1,000 2,835 0-0.06 1 - 56 ' ' 0.40 2-½x2½ 3.13 538 1.88 2.1 40 48 .3 6900 12615 0-1.6 . 79 137 1 48 1.0 2 2.375 1.000 4,430 0-0.06 r 31' 0.32 - 2 ½ 2½ 3.63 5.88 1.88 2.6 - SO 603 6900 19715 0-1.6 - 26 92 149 48 12 2½ 2.875 1,000 6,490 0-0.06 1,-151 0.26 2 ½ - x 234 4.25 650 1.88 3.1 73.0 6900 28880 0-1.6 22 . 108 165 48 . 1.4 761 mm 3.000 1,000 7,070 0-0.06 1' 12' 0.26 2-%x2% 438 6.63 1.88 32 76.1 6900 31460 0-1.6 - 22 lii 168 48 15 3 3.500 1.000 9,620 0-0.06 1' 2' 0.22 2 ½ 14 - x2 5.00 7.13 1.88 3.7 80 88.9 6900 46810 0-1.6 - 18 127 181 48 1.7 3½ 4.000 1,000 12,565 0-0.06 0. 54' 0.19 ¼ 2- X3/4 5.63 8.25 1.88 5.6 90 101.6 6900 55915 0-1.6 - 16 143 210 48 2.5 4 4500 1.000 15,900 0-0.13 . . 1 -36 0.34 2- ¼ x 314 6.13 8.88 2.13 6.7 100 114.3 6900 70755 0-3.2 28 1 156 226 54 3.0 - 1080mm 4.250 1.000 14.180 0-0.13 1' 41' 0.35 - X 2 16 825 6.00 8.63 2.13 11.0 108.0 6900 63100 0-32 - 29 . - 152 219 54 5.0 5 5363 - 1.000 24,300 0-0.13 I' 18' 0.27 - 2 34 4V 7.75 10.65 2.13 10.6 125 141.3 6900 108135 0-3.2 - 23 197 270 54 4.8 1330mm 5.250 1.000 21,635 0-0.13 r - 21' 0.28 - X 2-20x 108 7.63 1038 2.13 10.0 133.0 6900 96275 0-3.2 24 194 264 54 45 1397 mm 5300 1.000 23,745 0-0.13 1. 18' 0.28 - X 2 20 108 8.63 10.65 2.13 10.0 139.7 6900 105665 0-3.2 - 24 219 270 54 43 6 6.625 1,000 34,470 0-0.13 . . -s 0.23 44 2- X 863 11.88 2.13 12.0 150 168.3 6900 153390 0-3.2 18 219 302 54 5.4 Table continued on page 3. See notes on page 3. 14- 22' SIZES 24' SIZES www.victaulic.com i iv VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. ctauI 06.04_2 REV_H ..y.z .., '.- ... • .. ... .- - .. •- 24 SIZES IPS CARBON STEEL PIPE - GROOVED COUPLINGS 06.04 Standard Flexible Coupling STYLE 77 DIMENSIONS 7Nomin I Outside Deflect. Fr.Wgt. Each Size Diameter inches Inches 159.O 6.2SO mm 1,000 30,665 0-0.13 1 '9 1 0.24 Inches - 20 X 8.63 11.50 2.13 159.0 6900 136460 0-3.2 20 219 292 54 6.0 1,000 0-0.13 2-%x4V4 8.88 11.63 2.13 13.2 6.500 165.1 mm 33,185 -. . 1 -6 0.23 165.1 6900 147660 0-3.2 19 226 295 54 6.0 800 50' 2 - X 11.00 14.75 230 8 8.625 46.740 0-0. 13 0.18 20.8 200 219.1 5500 207995 0-3.2 - 14 279 375 63 9.4 10§ 10.750 800 - 73,280 0-0.13 0' 0.14 - 2 1 6 13.83 17.13 2.63 31.1 250 273.0 5500 326100 0-3.2 12 346 435 67 14.1 12§ 12.750 800 102,000 0-0.13 0' 4' 0.12 - 2 1 6½ 15.63 19.25 2.63 27.8 300 323.9 5500 453900 0-3.2 , 0 -31 9 0.11 397 489 67 12.6 14* 14.000 300 46.180 -- 0-0.13 4 1 3½ - X 16.63 19.88 2.88 35.6 350 355.6 2065 205500 0-3.2 422 505 73 16.1 15* 15.000 300 53,000 0-0.13 , 0 -29 0.10 4-1 x5lh 17.88 21.63 3.00 48.8 375 381.0 2065 235850 0- 3.2 454 549 76 22.1 16* 16.000 300 60,320 0-0.13 ' 0 - 27 0.10 4 - 1 3½ 19.00 22.13 3.00 51.1 400 406.4 2065 268425 0-3.2 482 562 76 23.2 18* 18.000 300 76.340 0-0.13 , 0 -24 0.08 - 4 1 3½ 21.38 24.50 3.13 64.4 450 457.2 2065 339710 0-3.2 543 622 80 29.2 20* 20.000 300 94.000 0-0.13 0 2' '2 0.08 4-1%x4 23.63 27.25 3.13 91.2 500 508.0 2065 418300 -0-3.2 600 692 80 41.4 22* 22.000 300 114,000 0-0.13 0 -19. 0.07 -1Vex4 25.75 2950 3.13 92.0 550 559.0 2065 507300 0-3.2 6 654 749 80 41.7 24* 24.000 250 113,000 0-0.13 . 0*- 18 0.07 6-1VeX4 27.75 3125 3.13 94.0 600 609.6 1725 502850 0-3.2 6 704 794 80 42.6 § Couplings 8, 10, 127200,250,300mm sizes available to AS standards. Refer to Section 06.17 for details. * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 34_ 3½720 - 90 mm; 25% for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. * For cut groove systems only. For 14- 247350- 600 mm Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Request publication 20.03 for information on the Style W77 flexible AGS coupling. 3A - 12 SIZES 14- 22 SIZES www.victaulic.com '%1taUIIC VICTAIJLIC IS REGISTERED TRADEMARK OF VICTAUC COMPANY. C 2006 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_H 06.04_3 -i - - ,. 1,. '_ - ,, ,.•. .1 ,ç"' - - The Superior Lightwall Threadable Bull Moose Tube Eddylite is a lightwall threadable pipe manufactured in NPS I" through 2". Eddylite is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. Corrosion Resistance Ratio (CRR) 1137 - 013 747 0.41 ...91 1482 0..08 479 0.34 ... 61 1900. 1.712 . .0.12 4.53 0.31:: . 61 2.375 2.177 016 431 036 37 Advantages of Bull Moose Tube Eddylite Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than schedule 40. Wall thickness and weight close to schedule 30; compare to other lightwall threadable products with wall thickness less than schedule 101 Q 1819 Clarkson Road For additionaflnformadon, c@ us Chesterfield, MO 63017 contact your salesperson today at BiLL. MOOSE TUBECOMMNy(800) 325-4467 (800) 325-4467 or (636) 537-2600 FAX: (636) 537-2645 in the USA, or from Canada www.bullmoosetube.com Call (800) 882-4666 <15> ACtWVcompany e-mail:sales@bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems in commercial and residential construction, Bull Moose Tube has added Eddy Flow to its comprehensive line of sprinkler pipe products. Eddy Flow is a specially engineered replacement for schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL listed (for U.S. and Canada) for roll grooving and welding for use in fire protection COMPARISON systems with a working pressure of 300 psi or less. Please check with appropriate sources for up-to-date listings and approval information. As an added benefit, it is more economical to use than schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's larger ID provides an opportunity for downsizing and further cost savings. 11/4 1.660 1.530 1.442 1.380 1.98 1 1/2 1.900 1.728 1.682 1.610 3.44 2 2.375 2.203 2.157 2.067 -. 2.78 21/2 2.875 2.705 2.635 2.469 1.66 3 3.500 3.334 3.260 3.068 1.00 4 4.500 4.310 4.260 4.026 1.00 Corrosion Resistance Ratio Dual Certified to ASTM A135 and A795. FM Approved for roll grooved, and welded, and plain-end application in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. UL Listed (for US and Canada) and FM Approved for use with Victaulle FflL Fittings In plain end applications. Lightweight - saves shipping costs, and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Floor stock available in various lengths produced in Casa Grande (AZ), Gerald (MO), and Masury (OH). Also can be ordered in custom lengths.. Can be used for wet and dry* systems. * Eddy Flow can be hot dipped galvanized to meet FM'S requirement for dry systems. PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1.00 1.00 1.00 1.00 1.00 1.00 For additional information, c®us As contact your salesperson today at USTED (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882.4666 Ae> APPROVED (NZ 13 0 BLLL MOOSE TLE COANY ACfli?lOcompany 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail:sales@bullrnoosetube.com All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the light to change product specifications without notice and without incurring obligation. 8/08 Ust5b APPROVEO wAvwh*-ff=m or r Prin t Page 2 of 3 AWl': Malleable Iron Screwed Fittings - Class 150 STRAIGHT 14: Nominal Size Dimension A Approx. Wt. Eoth lbs. (g) ¼ 069 0.09 4 I1J3 004 ¼ 0.81 0.14 $ 2057 004 ~ 0.95 0.21 PD 2433 010 ~ 1.12 0.31 2145 0.14 % 1.31 050 20 3321 023 1 130 0.79 25 3170 aji 1!.6 1.15 1.19 32 4M$ 054 14 1.94 137 4073 01: 2 2.25 2.43 so 57. is ito 2½ 2.70 4.33 38.53 1.96 3 3.00 6.37 40 78.23 23? 4 3.79 11.03 100 9321 S1 6 5.13 25.98 ISO 130.30 Dimensional: Fittings: ASME 816.3 Unions: ASME B16.39 Bushings/Plugs: ASME B 16.14 Material: ASTM A-197 Galvanizing: ASIM A153 (Hot Dip Galvanizing) Threading*: ASME BJ.20.1 Pressure Rating: Fittings: ASME B 16.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings ore tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions are UL Listed and FM Approved. British Standard threading per BS 21 available upon request. I-.' http:/Lwww.nyi1int1.com/ProductSearcb/PrintProduct.aspx?lid4381 . . ••.. - ..1/8/2014.. ... .. . - ._ * Print Page 2 of 5 Malleable Iron Screwed Fittings - Class 150 C®Le US1ID APPROVEO REDUCING _______ 0imentions Nominal Size A B C Approx. WI. Each AIL (mm) (1i. (mm) h. (mm) is. (mm) & (kg) ¼ 8 0.97 24.44 0.97 2944 0.98 2439 0.24 011 % 4I 1.04 2642 1.04 2642 1.03 24M 0.21 012 ½ 1h Ii 1.22 1.22 1.20 0.31 IS IS 247 3099 31197 3041 All 1 L36 1.36 126 0.49 25 3434 3454 32470 022 - ½ ½. iS 1.20 3213 112 _2614_ 1.22 2613 0.38 (U? V4 247 131 3227 122 7442 1.31 3123 0.45 070 15 - ½ 1.05 1.05 1.08 0.36 ~ 8 7847 2447 21.43 014 !4 in 112 2445 1.12 2845 113 2310 0.39 018 747 ½ 20 ½ 1.20 1.20 1.22 0.43 15 1 3048 30.48 3097 AN 1 1.45 1.45 1.31 0.62 28 24.43 &L&L J243 0.28 W 1 1.50 1.18 1.50 0.63 3 - 75 3210 7997 2310 --A291 -T h-- [1Z 136 .4 1.5 3230 2245 3454 (12? 217 34217 1.22 2445 1.45 3454 0.56 025 I 1.50 1.36 1.50 0.61 .25 38147 24.54 .3310 1 030 ½ 126 1.20 136 0.53 75 l230 3048 3454 AN ½ 414 137 1.31 1.45 0.61 20 __M.3fl 7423.. 21483 ......0.7t. 1 1.50 145 150 031 25 ____ _j. _30U7_ 3443 3470 022. 1.18 118 127 0.57 30 2991 2991 3224 41.74 T UF 1.26 1.36 0.62 IS 8730 3730 2354 0.78 T ....._ E31 2045 1.37 2085 1.45 34.63 (69 037 1 1¼ 167 1.61 158 0.94 25 .3 42.47 4242 401140117 043 1½ 1.80 180 165 1.01 41) 45)2 I 45.12 41.9) 0.41 V 2.02 2.02 133 1.45 577 Sill 53.37 1 4334 414,4 Dimensional: Fittings: ASME B16.3 Unions: ASME B16.39' Bushings/Plugs: ASME B 16.14 Material: ASTM A.1 97 Galvanizing: ASIM A-153 (Hot Dip Galvanizing) Threading*: ASME B1.20.1 Pressure Rating: Fittings: ASME Bi 6.3 Unions: ASME B 16.39 Bushings/Plugs: ASME 8)6.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are UL Listed and FM Approved. 'British Standard threading per BS 21 available upon request. REDUCING TE _______ Dimension Nominal Site A B C Approx. Wt.Each h (mm) It 0.s7J At (wo ThL 110 ½ 25 1 .........158 411 13 136 2454 .67 4242 0.82 0.37 1$ 1½ 472 1)5 4443 1.53 3286 1.15 44.43 0.95 043 ¼ 1.45 1.31 1.62 0.15 20 3413 3321 4045 034 41 1 158 1.45 1.67 0.87 20 25 10.13 2683 4242 4129 1% 1,15 1.62 1.15 1.00 42.45 A4M 0.45 ½ 134 1.26 1.53 0.74 IS 3104 320. 3916 034 4 -]37- 1.62 0.82 I 20 3483 2243 44.15 (121 1½ 25 1 1T8 13U 14 0.94 32 .25 477.13 32 to 47.42 043 1½ 135 1.67 115 1.08 32 4i4.5 4743 44,45 0.49 ¼ 126 126 1.44 0.18 70 37470 1230 I 3258 025 ½ 7.34 1.34 1.53 0.84 1.5. 3204 3404 38.34 033 ¼ 145 1.45 1.62 0,92 1 V4 20 . 33.27 3483 4015 0.42 1 158 158 16/ 32 .25 40.13 4243 4-2.42 ~04 417 4775 41.75 4623 2' 2.10 2.10 1.90 1.65 50 5534 5fl 49.24 0.15 htp:1/www..anvi1infl.com/ProductSearchfPiintProduct.aspx?iid=438O .,..............1/8/2014, . .. -. .. . -. s-.. Print Page 4 of 5 Malleable Iron Screwed Fittings - Class 150 REDUCI NG T1 ______ Dimensions _____ Ilaminol Sue A B Approx. . Each k (irn _ ti (M rd 6 (Add 1% (MM)(1 (5g) ½ jc 1½ 1.94 49.78. 1.66 4Z1& 1.94 2& 124 .fiA4_ ¼ 150 1.26 1.69 0.86 20 I/i 194 1.75 1.94 1.29 .411 4023 44.45 4R 050 1 165 E0 1:80 lOU 2.4 44.91 MA4572 049 1 1¼ 1.82 44.23 1.61 4W75 188 1.23 4.54 1½ 194 1.80 1.94 1.35 4U _4023_. ISIL 4fl8 .141. ¼ 1.52 1.45 1.75 1.04 *64 34.13 4.4.45 4.47 1 33 145 4091 158 40.12 IJO 4522 1.17 4.33 11h to 1½ 1W 112 135 IJ8 1J2 3Z 32 6423 4045 4125 4.40 1¼ 1.94 1.88 1.94 1.45 411 4028 4775 4028 I 005 2 2.10 2.10 1.90 1.87 10 5321 £3.34 4324 0.81 W. 1.41 1.41 1.66 1.04 Is _J$8LJ58L .42.34 14. ¼ 132 157 1.75 1.14 211 *41 3W 4143 4.52 1¼ I 165 1.65 1.80 1.21 23 IIM 44.91 1 4512 gSa 1i4 t82112881.4U 32 4423 44.23 4725 4.45 2 2.16 2.16 2.02 1.89 50 5424 5414 5021 4.84 ½ 2 2.25 1.88 2.25 1.89 IS 511 5/15 41.75 37.15 AS ¼ 2 2.25 1.91 2.25 1.93 23 50 5715 50114 37.33 084 1 1.81 1.75 1.81 1.39 1 74 4597 14.45 41.30 4.41 25 2 2.25 2.02 2.25 2.00 511 5715 51,2j Vis 4.91 iW 1.90 1.75 .10 1.64 .42 4024 44.45 il34 4114 1½ Th 2.02 118 2.I6 1.80 31 411 5121 4715 5414 0.82 2 2.25 2.10 2.25 2.09 30 5713 51.114 V.15. 4.95 1 1.13 165 2.02 1.51 25 1 4094 4004 5.1.31 014 2 114 1.90 1.82 .2.10 1.71 so 1½ .32 4324 4523 53.34 0.78 7; 2.02 1.94 2.16 1.88 40 40 5131 4928 3(88 045 2 2.25 2.16 2.25 :221 .50 S7I5 .J065 ½ 1.49 149 1.88 153 IS 87184 3135 41.1$ 4.49 ¼ 160 160 1.91 1.63 0 4064 4064 5004 074 1 1.73 1.73 2.02 1.78 2 .23 4094 43.94 5134 024 30 1A 32 1.90 4024 1.90 43.24 2.10 5.134 1.97 029 1¼ 2.02 2.02 2.16 2.12 411 ¶2.31 52.37 5488 024 25 2.60 2.60 2.39 3.15 64 4404 46414 1 414171 1,43 REDUCING II Nominal SIze - - - ' () . '1L tnvnl 2iOI . DimensionsW 2.372.84 - 14 1.74 174 20 4810 44120 1 1.81 187 75 47.50 4054. 4070 1129 21h 24 1½ .2.04 2.04 2.45 3.09 45 45 32 5047 SIll 4123 1.40 1½ .2.16 2.16 2.51 3.29 40 54.84 3486 1 4313 245' 2 _-L- 2.39 401L 2.39 d01L 2.60 _4&6L 3.5 14L ___ T 2 2.52 2.25 7.89 3.88 5.0 50 4002 4145 1342 124 - r4 1.87 I.87 2.61 3i2 2(1 41541 41150 44.29 159 1 .2.00 2.00 7.66 3.96 20 5020 5030 475.4. 1 14(1 3 73 3 1% 32 2:17 55.12 2.17 55.12 2.14 49.40 4.23 1412 lh 2.29 2.29 2.80 4.45 eo 441 5217 5311 1012 2102 7 2.57 2.52 2.89 4.90 511 84.01. MIII 73.41 2.22 7¼ 2.83 2.83 2.99 5.69 74.88 1188 15.9.5. 2.50 214 2.14 3.41 132 511 4940 60.40 7541 388 4 4 2½ 3.05 3.0 3.51 8.51 too Joe I 64 1741 1141 89.15 384 330 3.30 3.69 -9:25--- ______ LI) .5329 9722 9044 4.20. .com/ProductSearch/PrintProduq.t.kst)x?lid=4380 ...._... . .1/8201,4. - . ...... 519 APPROVES fib twaI*t1ccla Print Page 2 of 3 Iui p :[uTT, MANVIC Malleable Iron Screwed Fittings - Class 150 IIu1 :juYj ilominal Size Dimension A Approx. WI. Eath RL (MO A7. (437.1) th(kg) ½ 0,69 0.06 11J3 0.43 0.81 0.10 8 0,01 0.95 0.15 24.13 OR ½ 1.12 0.22 NO 1110 ½ 1.31 0.36 0.3321 0.16 1 1.50 0.57 25 3910 Of 1½ 1.15 0.87 22 #45 04 1½ 1.94 1.16 4923 0.53 2 2.25 1.81 53 5?75 OR 21h 2.70 3.23 55 4S8 IA? 3 3.08 482 13.23 4 3.19 8.41 V11 p621 341 6 5.13 19.96 153 3.339 ___710 __________ Dimensional: Fittings: ASME B16.3 Unions: ASME B 16.39 Bushings/Plugs: ASME B 16.14 Material: ASTM A-I 97 Galvanizing: ASTM A-153 (Hot Dip Galvanizing) Threading: ASME B1 .20. 1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions are Ut Listed and FM Approved. British Standard threading per BS 21 available upon request. ww.anvilintl.com/ProductScarch/PrintProduct.aspx?li 370 i/8/20,14 Print Page 2 of 3 :149111A [eIJ. 1! :j.]Y1Y,1 Malleable Iron Screwed Fittings - Class 150 U61110 *pRoveo xpacbj.1unwWW.actin REDUCING 90' 1II:IuiT Nominal Size Dimen sions Approx. Wt. mdi A ½ x ½ 0.74 016 0.08 8X6 IAAV 19.30 004 0.81 0.85 0.11 lOIS 2851 2159 005 0.88 0.90 0.13 1028 223$ 273$ 11.114 0.91 0.98 0.16 I5i8 243$ 24.89 001 !hx* 1.04 1.03 0.19 IS 1O 2542 2618 009 1.12 1.13 0.26 20s'10 2445 28)0 0.12 A X½ 120 112 0.29 2O15 3048 3099 0.13 1 x½ 1.18 1.26 0.35 zcxlo 29.91 3740 0.15 1 x½ 126 1.36 0.42 )SY 15 3240 3054 0.19 12% 1,37 1.45 0.47 25x20 34.40 36.83 all 11/41½ 1.34 133 0.54 32x 15 34.114 3284 0.14 1.45 1.62 0.62 3740 38.02 .1.15 023 1%xl 1.58 1.67 033 3705 4813 42.47 033 1½ x14- 1.38 1.65 0.65 lOx is 31.05 41.91 0.29 132 1.15 034 40120 3W 4445 034 11h x I 1.65 1.80 0.88 25 41.91 .1512 0.40 11Ax1% 1.82 1.88 1.03 4873 4715 041 2xt6 1.50 1.89 0.93 5M' 15 3410 .8.01 0.42 2x'i 1.60 1.97 1.04 5040 433$ 50.04 041 2x1 113 2.02 1.28 50x25 4I1!4 51.31 0.53 2x1% 1.90 2.10 1.36 4474 5734 082 2x1½ 2.02 I 2.16 131 50x40 $1.31 5486 044 Dimensional: Fittings:ASME 816.3 Unions: ASME B 16.39 Bushings/Plugs: ASME 816.14 Material: ASTM A-197 Galvanizing: ASTM A.153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B 16.14 Pressure Testing: All malleable iron Fittings ore tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are lit Listed and FM Approved. 'British Standard thteoding per BS 21 available upon request. lREDUCING IIs4:Ia1Y DimensionsB Nominal Size Approx. Wt. lath A 0. (MO) ibs(igl 2½z 11ñ 2.16 2.51 2.20 AS If 48 3484 8313 i 00 2½ x2 2.39 2.60 235 65150 £011 804 US 3x2 232 2.89 3.35 4050 64.01 13.41 1,57 3x2½ 2.83 2.99 4.12 1188 1535 181 4x2 232 33 5.01 106 $0 49.09 . iii? 222 40 3.30 3.60 6.65 _ 83.82 9114 3.02 pt1.comRroductSearchrintProduct.aspx?1id=437i . .. ... . .1/8/201.4. .. .. . '. .s I -. - Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 UUIA APPROVED tm(l1IJ!JIkte Nominal Size Dimension A Approx. Wt. lath At At lbs. (gi ½ 0.96 0.05 An -0.02 ¼ 1.06 0,08 8 202 004 ½ 1.16 0.12 HP V.46 0.05 ½ 1.34 0.17 15 34.04 ½ 1.52 0.27 20 3161 0.12 1 1.67 0.43 25 4142 OJO 1½ 1.93 0.65 37 49.02 029 1½ 2.15 0.86 40 54M 039 2 2.53 1.35 50 6426 0.41 2½ 2.88 2.33 45 73:15 1.04 3 3.18 3.36 S9 I7 9.52 4 3.69 5.59 93)3 2.54 Dimensional: Fittings: ASME 816.3 Unions: ASME B116.39 Bushings/Plugs: ASME B16.14 Material: ASTM A-i 97 Galvanizing: ASTM A-153 (Hot Dip Galvanizing) Threading*: ASME B1.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron linings are tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are UL Listed and FM Approved. British Standard threading per BS 21 available upon request. .http://www.anvi1intLcomfProductSearch/PrintProduct.aspx?1id=4374.... Print Page 2 of 3 ANVIL Malleable Iron Screwed Fittings - Class 150 umø AWROVED REDUCING COUPLING Nominal Size Dimension A Apptox. Wt. Each x 14 1.00 0.07 8.r6 25.40 OR 1.13 0.09 10t6 2UO 004 ½x V4 1.13 010 10:8 WV 0.05 ½x'A 1.25 013 Isys 31)5 CLOd ½x½ 1.25 0.13 15:8 317$ 006 1.25 0.14 15,10 31.75 006 1.44 0.18 204 36.9 003 ½1114 1.44 0.20 20:8 34.38 0.0? 1.44 0.2) 70:10 3L. 0)0 1.44 0.22 70:15 308 OW 1 xt4 1.69 0.34 25:15 42.23 015 1.69 0.36 25:20 4213 016 1%: ½ 2.06 0.47 32,15 52.32 021 I½x 114 2.06 0.51 32:20 57.32 023 1%:) 2.06 0.57 31:75 52.32 074 l½ich 2.31 0.62 40:15 58Ai 0.28 Dimensional: Fittings: ASME 816.3 Unions: ASME B16.39 Bushings/Plugs: ASME 816.14 Material: ASTM A.197 Galvanizing: ASIM A-153 (Hot Dip Galvanizing) Threading*:* ASME 81.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME B 16.14 Pressure Testing: All malleable iron Fittings are tested for through wall porosity using on air under waler process. Agency Approvals: All malleable iron Fittings and unions are UL Listed and FM Approved. British Standard threading per B$ 21 available upon request. REDUCING lCOUPLING Nominal Size Dimension A Approx. WI. Each 2116 2.81 0.94 SOt 15 11.37 0.43 2x½ 2.81 0.99 50,20 I.31 045 2 xl 2.81 1.03 5025 71.57 041 2x1½ 2.81 1.17 5632 71.57 053 2x1½ 2.81 1.25 .5O40 71.57 0.51 2½x1% 3.25 1.81 8255 0.82 21h: 1½ 32S 1.90 45:49 016 2½ :2 3.25 2.04 453,50 87.55 0.23 3x] 3.69 2.48 bris Ut 3:1% 3.69 2.55 t$ 73 1.14 3:1% 3.69 2.61 4Jr 49 ?3.73 7.21 3:2 3.69 2.78 8h 50 ?3.73 7.24 3:2% 3.69 3.23 033 7.41 4:2 4.38 4.43 11S0 111.25 101 4:2% 4.38 4.87 165 111)5 2.71 4:3 4.38 5.29 1I1,25 2.40 Print Page 2 of 3 IJIufeI Malleable Iron Screwed Fittings - Class 150 C®. <3> UCIE) APPROVED rw mm Affivamn JIuIe Nominal Dimensions _______ Approx. A B C Size WI. Each Li. vI M. (nW k (W) Li. (MM)& ½ 0.44 4 sow 0.28 0.38 0.04 8 11.11 1.11 1 965 0.07 sow 3 0.48 0.31 0.44 0.06 10 17.19 721 all 0.03. Cord ½ 0.56 0.38 0.56 0.08 14.22 945 14.72 0.04 Cord 5 0.63 0.44 0.63 0.13 16.0) 71.78 I60 O.CS Cord 1 0.75 0.50 0.81 0.20 75 19.1)5 12.10 3351 0.09 Cored 1½ 0.80 0.56 0.94 0.32 37 3332 14.22 230 0.1$ Cored 1½ 0.83 0.62 1.13 0.43 43 71.03 ISIS 23.10 072 Cored 2 0.88 0.68 1,31 0.67 53 27.35 1127 13.2? 033 Cored 2½ 107 0.74 1.50 1.11 65 2/i8 18.3 39.10 050 Cored 3 1.13 0.80 1.69 1.53 C 28.73 20.32 4253 069 Bar Rug 4 1.22 1.00 - 2.11 1C3 3099 7543 - L73 6 1.40 125 - 4.00 150 3536 31.15 - ia, Dimensional: Fittings: ASME 816.3 Unions: ASME B 16.39 Bushings/Plugs: ASME 81614 Material: ASTM A-i 97 Galvanizing: ASIM A-153 (Hot Dip Galvanizing) Threading: ASME 81.20.1 Pressure Rating: Fittings: ASME BI 6.3 Unions: ASME B 16.39 Bushings/Plugs: ASME B 16.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL Listed and FM Approved. British Standard threading per BS 21 available upon request. - . ,http://wvanvi1int1.com/ProductSearchRiintProduct.aspxflid=4378 .. - 1/8/2014 - Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 C®Es 43> (DIED APPROVED Nominal Size Dimension A Appsox. Wt. Each 0.53 0.03 OIJI 0.63 0.05 8 1400 0.02 0.74 0.07 to 1820 0113 ½ 0.87 011 Is 2Z10 0.05 14 0.91 0.18 20 2424 0118 1 1.16 0.30 25 2846 0.14 16 1.28 0.44 37 2731 020 1½ 1.33 035 025 2 1.45 0.85 SO 3483 028 2½ 1.10 1.49 65 43.13 048 3 1.80 2.20 80 (5)2 1110 31h 1.90 3.02 4826 121 4 2.08 3.19 71311 .283 U72 6 235 8.17 150 1 64.71 1 588 £- 5uped in 5h3d ot4y (Bokaid GènizdI. 7llllIIIllIll~MATERIAL SPECIFICATIONS Dimensional: Fittings: ASME 816.3 Unions: ASME B 16.39 Bushings/Plugs: ASME 816.14 Material: ASTM A-i 97 Galvanizing: ASTM A.153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions ore UL Listed and FM Approved. 0 British Standard thieading per BS 21 available upon request. ..Sarn p 1/.8/20 14 -:: P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 Inch pipe LISTED FOR STEEIJCPVC 112&3J4 Inch pipe 5 thou B Inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - 03 um 203-EX 2551 1"- 8" S' Approval guide -1"-S" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. NFPAI3 PIPE ROD I W1 5WL+250 UL TEST LOAD 1 318 30.75 403.75 750 1114 318 43.95 469.75 750 1112 318 54.15 520.75 750 2 318 76.95 634.75 750 2112 318 118.35 841.75 850 3 1 318 182.30 1061.50 1050 4 318 246.00 1480.00 1500 5 112 349.45 1996.75 2000 _•j_ 476.35 2631.75 2650 8 _ 112 1 711.00 3805.00 4050 PIPE A B _!_ 9.8703 2.5259 1114 2.1382 2.7850 I in 2.2673 2.8140 2.6049 3.2516 2112 3.4928 4.1150 _.L_ 3.7845 4.4311 _.±._ 4.3582 4.8992 _.L_ 6.9668 6.8100 7.5765 8.3290 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Ranger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting ins listed sway bruce, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to lass of business or profit, when non-.AFCON products have been, or ale used. 1/08 - 4 4 Fig. 98 -Ro&Stiffener Size Range - Secures 3/8' 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod fo Approvals - Underwriters Laboratories Listed in the ULI Canada (cUL). Included in our Seismic Restraints Cat app Component of State of California OSHPD Appy Seismic Restrairits.8ite Finish — vailable in HDG finish or Stainless Steel materials. By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1¼ 8000 7140 360 1½ 11630 10370 510 D OFFICE/MANUFACTURING FACILITY. 1315 SAMPSON AVE. • CORONA. CA 92819 • PH: 951.737.5599 • FAX: 951.137.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com -'• . .-' :4 Dimensions • Weights Rod Size Outside Diameter Approx. WtJIOO 3/8 11/16 .6 1/2 7/8 1.3 5/8 11/. 2.4 3/4 11/4 4.0 Fig. 113 - Standard Hex Nut Size Range - Sizel/4" thru IV? Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish Fig. 114 - Heavy Hex Nut Size Range - Sizel/4" thru 11/2I Material - Carbon Steel• Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Dimensions -Weights Width Width Rod Across Across Approx. Size Flats Points Thickness Wt./j00 1/4 7/16 1/2 7/32 .7 5/16 1/2 37/64 17/64 1.1 3/8 9/16 21/32 21/64 1.6 1/2 3/4 55/64 7/16 3.7 5/8 15/16 13 /32 35/64 7.3 3/4 11/ 1I 41/64 12.0 7/8 1/ 04 3/4 19.0 1 11/2 1/4 55/64 28.0 11/4 1/ 2"64 11/ 54.0 11/2 21/4 21 I 1 /32 94.0 Fig. 115 - Flat Washer Size Range - Sizel/4" thru I/2" Material - Carbon Steel Finish - Plain Note -Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish Dimensions • Weights Width Width Rod Across Across Approx. Size Flats -- Points Thickness Wt!Ioo 1/4 1/2 37/64. 15/64 1.2 5/16 9/16 21/32 19/64 1.7 3/8 11/16 51/64 23/64 3.1 1/2 7/8 116 31/64 6.5 5/8 11/I6 1'I 39/64 12.0 3/4 11/4 1/ 47/64 19.0 7/8 17/16 121/22 55/64 30.0 I 14 17/e . 63/64 43.0 11/4 . 2 25he 1 /32 79.0 - 11I2 2/. 2I4 1 /32 131.0 Fig. .117 - Lock Washer Size Range - Sizel/4" thru 3/4" bolt Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number size and finish Dimensions -Weights Rod Size Outside Diameter Approx. WtJ100 1/4 3/4 .7 5/16 1 1.5 3/8 1/ 3.9 1/2 1/4 7.7 5/8 7.3 3/4 2 11.0 7/8 2'/4 1 2/4 3 11/2 3'/2 19.0 22.0 26.0 39.0 Page 63 officelManufactwing Facility. 1315 Sampson Ave. • Corona. CA 92819 • Ph: 951.131.5599 • Fax: 951.131.0330 Customer Service • 800.186.5266 www.tolco.cam F q3 < FM c&s LISTED APPROVED 9R21 Approvals itiIsI:1 Pipe Hanger Approvals O!II1 • 9$9~ 44(0 •- 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1.1/2" 300 1-1/2" 8008957 GST 20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST 20-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST 30 3/8" Vertical 4 1500 1-1/2" 4" 1475 14/2' 8009925 GST 25-380 3/8" Horizontal 4' 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-112"-4"° 1500 1-1/2' 8021957 SWG 20 3/8" Horizontal 2-1/2' - 3** 1050 1-1/2' 8073925 SWG 20-SS 3/8° Horizontal 2-1/2' 850 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2' 4" 1475 1-1/2" 8141957 SH-GST3O 3/8" 17" Angle off Vertical 1500 1-1/7 4" 1475 1-1/2" Pipe Hanger Approvals - [N !k 1LJ i h omew 8038957 DSTR 1 3/8' Vertical 4 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4 1500 .035' 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4' 1500 .037" 4' 1475 .105' 8045957 DST 516 3/8° Vertical 4' 1500 .188' 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4' 1500 .250' 4" 1475 .188' 8055957 SWDR 1 3/8" Horizontal 4' 1500 .037' 4' 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4° 1500 .037" 4" 1475 .060 8054957 SWDR 1-1/2 3/8" Horizontal 4' 1500 .037' 4" 1475 .060" 8137957 SH-DSTR 1 3/8" 17 Angle off Vertical 4' 1500 .035' 4" 1475 .105' 8150922 XP 20 3/8' Vertical 2-1/2" 850 .027" 7 940 .02T 8153922 XP 35 3/8" Vertical 3-1/2' 1250 .060" 8294922 SXP 20 3/8' Vertical or up to 45° 2' 750 .027' 2" 635 .029" 8295922 SXP 35 318" Vertical or up to 89° 3-1/2° 1250 .060" 2' 635 .029" 8293957 SWXP35 3/8" Horizontal 3-1/2" 1250 .060' - Pipe Hanger Approvals N Part No. M d Model Rod Mount UL Max UL Test UL Min FM Max FM Test FM Mm Size Direction Pipe Size Load (Ibs) PSI Pipe Size Load (Ibs) PSI 8059957 CST 20 3/8' Vertical 4" 1475 3000 8061957 SWC 20 3/8' Horizontal 4 1475 3000 8150922 XP 20 3/8' Vertical 2-1/2" 850 Pre-Pour Structural © 3000ps1 8150922 XP 20 3/8' Vertical 2-1/2" 850 Post-Pour Range II LWC 9 35 PCF (lbs/fl3) SWG 25-300 Mxbman pipe size In conpebvod joint zraiwsd by UL Is 3-112" 'SWG 25M Maxbnum pipe size In wood frnber or joist a?wad by ULIs 4' °SWG 20 Midmum pipe size In composite wood jotait r1lswnd by UI. Is 2-112" SWG 20 Mxtmum pipe size In wood tmber or jdzt Lowed by UL In 3" SarnmysP and Truss-T Hangers are registered trademarks of 11W Budex and lCnois Tool Works Inc. 02003 11W BuOdex and tnotx Tool Wsaks. Inc. REV. 0203 SSS40 UI. said FM teatai was psafonrod In complsaice with NFPA 13 Steaidsa Fastening roqntcmcrt 5 Omen wo!hl of wzter412cd schedule 40 pIpe ples 250 pounds. - LBullaex www.itwbuildex.com 800-BUILDEX P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH SIZE - ROD 3/8" SIZE - SYSTEM PIPE 4" max SIZE - ROD: 1/2" SIZE - SYSTEM PIPE: 8" max. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL- g@0203-EX 2551 4 FM Approved -I95I FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on steel flange - thickness less than 3/4". Set bolt up or down. ASSEMBLY/ATTACHMENT - See drawing. Torque - 3/8"= 60 lb-in or 1/2" 125 lb-in. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/4 turn. Caution - Do not over tighten set bolt. FEATURES * Maintains CONSTANT HANGER CENTER-LINE, with set bolt up or down. * Flat throat back to prevent twisting on structure during installation. ORDERING - Part #, rod size and finish. 1/10 -. .-. . f-.................... Dimensions Size A B C 0 Rod MOIR.Up 3/8" 2.96 10.75 1 1.19 1.54 0.78 1/20 3.62 10.75 10.97 11.75 0.72 Part #5 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 615 SWIVEL SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. SIZE - ROD: 1/2" SIZE - SYSTEM PIPE: 8" max. MATERIAL - Carbon Steel. FINISH — Mu. Galvanized and E.G. LISTING/APPROVAL — SO 203-EX 2551 FUNCTION — Pivot component of an AFCON hanger. Used to provide angularity of the hanger assembly. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. FEATURES * Deep rod bore. * Improved hanger adjustment. * More pivot clearance at T.B.C. — See detail A. ORDERING - Part #. #100 out 10/Il 17I32 DUCTILE BASE PLATE P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 076 ATTACHMENT FITTING UNIVERSAL LOCKING 17/32 STEEL BASE PLATE SIZE - BRACE PIPE: 1" thru 2" Sch. 40 MATERIAL - Ductile iron and Carbon Steel. FINISH - Plain or E.G. LISTING/APPROVAL - um 203A-EX 2625 c$ FM Approved - 1950 OSHPD See Website. FUNCTION - Structure attachment fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per NFPA 13 or FM 2-8 and these instructions. Load rating - see chart. Combine with proper AFCON components- see disclaimer below. ASSEMBLY Insert brace element into fitting snug against back ofjaw. Install set bolt finger tight, then additionally tighten 1 1/2 turns or torque to 40 lb-ft. FEATURES * Swivel allows attachment at any angle. * Larger fastener hole available.- Consult factory. ORDERING - Part #, size - brace pipe, material and fmish. Max. Horizontal Load Size 1-2 Ductile Base 2765 3250 Steel Base 2765 3250 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners. resulting in a listed sway brace. restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold byAFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or ate used. 9/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 410 SWAY BRACE FITTING Part #077—....., rt #078 SIZE - 1 thru 8 inch pipe. MATERIAL - Carbon Steel or S.S. (Type 304). FINISH - Plain, E.G., and H.D.G. LISTINGS - Sus EX 2625, EX 2551 Listed only for use with other AFCON bracing products. OSHPD pending. FUNCTION - Pipe attachment component of a longitudinal or 4-way sway brace, consisting additionally of AFCON 70 series attachment end, AFCON 80 series adapter as required and brace pipe element forming a complete sway brace assembly. INSTALLATION - Per NFPA-13. Assemble 410 over pipe to be braced, install 70 series attachment end on outside of clamp ears and tighten bolts to minimum required torque of 40 ft.lbs. 078 is the preferred assembly component for use with the 410 - see drawing. FEATURES * UL Horizontal Load Rating: 1-3 pipe size = 500# 4-8 pipe size = 2015# * Made with 1/2" bolts to conform with sway brace fittings. ORDERING - Part #, pipe size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or arc used. 9/06 [ii ® Listed Max. Horizontal Load System NPS Sci. 30°.44 45".59" 60"-89" 90" 1-_11/2- jQ f383 jfi 2394 2765 2"-4" J4Q, 1383 1956 2394 2765 . .lQ. 1383 1956 24 2765 5" jfl J 294 2765 10" 10-40 1383 1956 2394 2765 IT -110-401 1870 1 26451 3238 1 374U Certified Max. ASD Horizontal Loads - Syste NPS m Sub. 30.44 45.59" 60"-74" 75.9Q 1"-i 1/2" 10,40 1680 2 0 2'-3- 10,40 1800 2350 3120 3490 4" 10,40 1370 1930 2370 2640 5", 6", 8 10,40 730 1040 1270 IA-- SPECIALLY LISTED PIPE A ST Pipes PVT LTD Al macma Steel Products Co. SAOG Allied Tube & Conduit Carp. Bihar Tubes LTD. Blunulool Services L L C Bonssan Mannesmann Ron, AS Bull Moose Tube Co. Conaen Metal Supply LTD. hal Chin Worldwide LTD Hickman Pipe & Tube Corp Jindong Economy Development Testing Zone Jiodul Industries LTD Jot,ndro Steel & Tubes LTD Mitsui Canada Inc. MS Pipe Co. LTD Northwest Pipe Co. Pacific Pipe Public Co. LID Saha Thai Slant Pipe Public Co. LTD Shield Fire Safety & Security LTD Stayu Roshini LTD Swastik Pipes LTD Ten-Tube Co. Universal Tube & Plastic Industries LTD Weilbog East Pipe lndast.y Technical Co. LTD Welded Tube. Berkeley LLC Wheatland Tube Co. Wit Div. Y,ch Phoi Enterprise Co. LTD Youngstown Tube Co. Zenith Bids (India) LTD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 035 SWAY BRACE FITTING MODEL Ah I thru 4 Inch pipe S thru 12 Inch pipe SIZE -SYSTEM PIPE: Nominal Steel 1" thru 12" * Steel Specially listed - see chart. CPVC 1" thru 3". Brace common O.D. - Copper, Plastic, FRP, Ductile and Cast Iron SIZE - BRACE PIPE: 1" thru 2" Sch. 40 Mm. 11/4" required for 12" system pipe MATERIAL - Carbon steel and ductile iron. FINISH - Plain or E.G. PATENTS - No. 7,516,922 No. 7,523,895 LISTING/APPROVAL- 203A EX 2625 FM Approved - 1950 OSIIPD See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through bores to achieve minimum 1" extension. Tighten 035 set screws until heads bottom out. FEATURES * Patented - designed for system pipe of varying material. * Improved assembly - extra large bore for brace pipe. * Visual inspection, verifies proper installation. * Superior load ratings. ORDERING - Part #, size - system pipe, size - brace pipe and finish. * COMMONLY KNOWN AS SCH. 7 Special Note: Thin wall sprinkler pipe has a propensity for damage to its circumference resulting in egging. When condition exists - shift mounting location. Specific AFCON products arc exclusively designed tube compatible ONLY with other AFCON products including pants and fasteners, resulting ins listed sway brace, restrainer or hunger assembly. Be advised she following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, pacts or Systems not manufactured or sold by AFCON. AFCONshall NOT be liable under any circumalanccs whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-4FCONproduets have been, or arc used. 3/13 LJ P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org SWAY BRACE ADAPTER WIDE FLANGE / I-BEAM SIZE RANGE - 1/2" Rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTINGS - c us EX 2625, EX 2551 Listed only for use with other AFCON bracing products. OSHPD pending. PATENT - No. 6,334,285 FUNCTION - Sway brace adapter used to attach an AFCON sway brace assembly to a wide flange or I-Beam steel structural member. To provide a point of connection when drilling is not allowed or impractical. Also can be used to attach to a steel web joist with a formed top chord. (See Drawing) INSTALLATION - Per NFPA-1 3. Per drawing, insert 1/2" x 1 1/4" attachment bolt into 086 bracket. Install 1/2" threaded studs thru both brackets and engage on steel flange. Assemble nuts on studs and tighten. Install nuts finger tight, then additionally tighten 1/2 turn or torque to 40ft. Lbs. Attach AFCON sway brace assembly on 1/2" bolt. On steel web joist with formed top chord install within 6" of the panel points. * 1/2" threaded studs and fasteners furnished by customer. FEATURES * UL load ratings at 30° thru 90° horizontal: Perpendicular to beam - 2015# Parallel to beam - 1265# * Universal, any flange width having thickness of 1/4" thru 1 1/4". * Studs capture head of bolt, providing hold back. * Alternative to center loading beam clamp. * UL listed hanger attachment for 8" pipe. ORDERING - Part # and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including puns and lhsteners, resulting ins listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- 4FCONwill NOT warrant against the failure of its products when used in combination will, other products. parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when ,so,sAFCON products have been, or are used. 7/06 àI[1L POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD U.S. Pat No. 3921989 Canadian Pat No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2' thru 8' (50mm thru 200mm). LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die- cast housing. The cover is held in place with two tamper resis- tant screws which require a special key for removal. A field in- stallable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL,ULCandCSFMListed,FMandLPCBApproved,NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) Minimum Flow Rate forAlarm: 10 GPM (38 LPM) Maximum Surge: 18 FPS (5,5 m/s) ContactRatings: Two sets of SPDT (Form C) 15.O Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA 4/I P54 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/1200F, 4,50C/490C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use:. Automatic Sprinkler NFPA-1 3 One or two family dwelling NFPA-1 3D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be in- stalled within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8!' (50mm ±2mm). Clean the inside pipe of all growth or other material for a dis- tance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. 08800001 - REV W PAGE 1 OF 2 MFG. 95400761 - 7/02 Page 72 FIG. 2 DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL 50111.-LBS (66 n-m) OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFI.OW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERELOW APPROX. RETARD SETTINGS (IN SECS,) o 0 I A 10-25 B 20_40 1 35 55 0 50-70 C 60-90 OPTiONAl. TAMPER SWITCH RETARD ADJUSTMENT; TO CHANGE TIME TURN KNOB (OTHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS. A 8 SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO V. TO INSTAL.L. DRILL HOLE AS INDICATED. PIPE SIZE HOLE SIZE to 2 1/2" 1 1/4" +1/8" -1/16" (50mm to 65mm) (33mm ±2mm) to 8" 2" ±1/8" (80mm to 200mm) 50mm ±2mm) Cover Tamper (with cover in place) £11 DWG. #761-30 DIRECTION OF WATERFLOW FIG. 4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. DWG 1761-4 (E)POTTER The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG. I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL . 10233 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: The Model VSR-F has two switches, one can be used to WI loa 2 ___ Operate a central station, pro- 6LY TW5 cum 61 MAMI am , prietary or remote signaling IF unit, unit, while the other contact is used to operate a local audible or visual annunciator. IiI • A condition of LPC Approval of Be 1C me I10 "low this product is that the electri- 6116so= in _ POIRRM ACADICIC cal entry must be sealed to MI 41M 6€TI5 MI WL) 61 I€u6IL ic '—' exclude moisture. V1 11€ arm 6 6 Be WI6. OTO — 161.2 For supervised circuits see "Switch Terminal Connec- tions" drawing and caution note (Fig. 1). APPLICATION WARN INGI Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001 - REV W PAGE 2 OF 2 MFG. #5400761 - 7/02 Page 73 Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (340 to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT .TYPICAI. dB AT 10 Ft (3m)(2) MINIMUM dO AT 10 Ft (3m)(1) 6(150) 12VDC P80126 1706012 .12A 85 76 8(200) 12VDC P8D128 1708012 .12A 90 77 10 (250) 12VDC P801210 1710012 .12A 92 78 6 (ISO) 24V00 P00246 1706024 .06A 87 77 8(200) 24VDC P0D248 1708024 .06A 91 79 10(250) 24VDC P802410 1710024 .06A 94 80 6(150) 24VAC P8A246 1806024 .17A 91 78 8(200) 24VAC P0A248 1808024 .17A 94 77 10 (250) 24VAC PBA2410 1810024 .17A 94 78 6(150) 120VAC PBA1206 1806120 .05A 92 83 8(200) 120VAC PBA1208 1808120 .05A 99 84 10 (250) 120VAC PBA12010 1810120 .05A 99 86 (E)POTTER The Symbol of Protection 6" BELL SHOWN BELLS PBA-AC & PBD-DC UL Listed Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC > I2OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company • 2081 Craig Road, St Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833*www.pattersignal.com PRINTED IN USA MKT. #8850001 - REV S PAGE 10F2 MFG. #5400776 - 5/05 Page 74 ...,, . ......- FIG.3 D.C. BELLS (OBSERVE POLARITY) RED (II) RED (Cul) FROM CONTROL, PMEL Ill TO NEXT 6W. OR OR END-OF-LIKE PRECEDING 6W. RESISTOR BLACK (W) a.oc (OUT) CAUTHOW SHOW ELECTRICAL 9JiN IS RECIJRCD USE IN AND GIST LEADS AS SHOWN. Pt (250) Lit 2 11/16 '(68 8" (200) 6" I (150) DAC. p776-I fall J 5 3/4" (146) (41) WIRING (REAR VIEW) BIBlE (IN) WHITE (Out) FROM OWOR NTROL PAM (OUT) REECHO 6W. BLACK ____BLACK I ____ WHEN O.ECTRIC*I. SWEXHBION IS REOLARCO USE 54 AND CUT LEADS AS SHOWN. EJ3 318- 4 1/4- (108) DING. 0776-2 A.C. BELLS (E)POTTER The Symbol of Protection BELLS PBA-AC & PBD-DC DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOF BACKBOX BOXHASONETHREAOED 1/2°CONDUITENTRANCE NOTES: NOTES: OBSERVE POLARITY TO RING D.C. BELLS, I. WHEN USING A.C. BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY RED WIRES POSITIVE (+) AFTER LAST BB .L. 3, BLACK WIRES NEGATIVE (-) 2. DID-OF-LINE RESISTOR IS NOT REQUIRED ON A.C. BELLS. DWG. #776-3 INSTALLATION The bell shall be installed in accordance with NFPA 72 or local Ahj. The top of the device shall be no less than 90" Aff and not less than 6" below the ceiling. Removethegong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REVS PAGE 2 OF 2 MFG. #5400776 - 5/05 Page 75 -D'-IT.-- Technical Data Model: Sprinkler Head Cabinet Style: 3, 6 or 12 head Standard Finish: Red enamel Mfgr. Source: Non-domestic' Capacity: 3 sprinkler heads 6 sprinkler heads 12 sprinkler heads Dimensions: 3 head -5" high x 71.4" long x 21W deep 6 head -5" high x 14" long x 31/4I deep 12 head -5" high x 14W long x 5fl deep Weight: 3 head - 1.5 lbs. 6 head - 2.3 lbs. 12 head -4 lbs. 3r 6 & 12 Head Sprinkler Head Cabinet Sprinkler Head Cabinet Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 ! P4 Product Description Central Sprinkler Head Cabinets are constructed of a metal enclosure with a hinged cover designed to provide on-site storage of an emergency supply of sprinkler heads and a sprinkler head wrench. NFPA 13 requires a representative number of each type of sprinkler head used in a sprinkler system to be stored in a cabinet on-site to allow for immediate removal and replacement of sprinklers which may have operated or become damaged. Central Sprinkler Head Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate either 1/2" or 3/4" N.P.T. threaded sprinkler heads and are painted an attractive red enamel. They are available in three (3), six (6) or twelve (12) head capacity. Page 76 No. 28-6.0 T rt - SERIES LCI INTUMESCENT SEALANT PHYSICAL PROPERTIES - APPLICATIONS SpecSeal® LCI Sealant has a broad application base designed to seal a wide variety of common penetrations in right commercial and grouped residential construction. Penetrant types include insulated and non-insulated metallic pipes and tubes, non-metallic pipes and tubes, and common electrical service and power distribution, telephone, data, and TV cabling. This product is also used in conjunction with other SpecSeal® Products such as SpecSeal® Firestop Collars and Wrap Strips to protect larger plastic pipes. See Table A for a summary application list Properties Series id Color Red Odor Mild Latex Density 9.0 lb/gal ((.08 kgt) pH 9.0 In Service Temperature i 13O°F4°C) Flame Spread 0' Smoke Developed 5' SIC Rating 62 (ASTM E90/ASTM C919) VOC Content 029Ls] Og&) (EPA Method 24/ASTM 03960) Shelf Life 2 yrs Volume Expansion lox Free Expansion Storage Temp. & 130'F(54°C) bvdbM111E8J39J14%o1aTwboia)To1edtoub seai) PRODUCT DESCRIPTION SpecSeal® LCI Sealant is a versatile and economical intumescent product intended for firestopping a wide array of applications in small commercial or grouped residential construction and other structures with similar applications. SpecSeal® LCI Sealant is available in a single grade that has excellent caulk- ing properties as well as high build properties on vertical or overhead surfaces. This single grade may be caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeal® LCI Sealant does not contain PCB's or asbestos. SpecSeal® LCI Sealant is storage stable (when stored according to the manufacturer's recommenda- tions), and will not separate or shrink when dried. SpecSeal® Series LCI Sealant will adhere to all com- mon construction and penetrant materials and contains no solvents that might adversely effect plastic pipes or cable jackets. Economical: High performance without the high price! Highly Intumescent: Expands up to 8 times. Excellent Smoke Seal Water Resistant: Will not re-emulsify when dry. Water-Based for easy installation, cleanup, and disposal. Acoustically Tested: Reduces noise transmission Safe Low VOC's, No Solvents, Non-Halogenated Palntabie PERFORMANCE SpecSeal® LCI Sealant is the basis for systems that meet the exacting criteria of ASTM E814 (UL1479) and ASTM E1966 (UL2079) as well as to the time-temperature requirements of ASTM El 19 (1.11.263). LCI provides up to a 2-hour fire rating for typical service penetrations through concrete or wood floors, concrete or masonry walls, as well as gypsum board walls (3-hour for metallic pipe, conduit and tubing). SpecSeal® LCI Sealant meets Class A finish requirements for Flame Spread and Smoke Development when tested in accordance with ASTM E84 (UL723). SpecSeal® LCI Sealant is also acoustically tested, demonstrating excellent sound attenuation properties. =BM'/cZ SYSTEM COMPATIBLE FILL, VOID OR CAVITY MATERIALS FOR USE IN JOINT SYSTEMS AND ThROUGH.PENETRAT1ON FIRESTOP I <Zi> c®u SYSTEMS. SEE UL DIRECTORY OF PRODUCTS CERTIFIED S FOR CANADA AND UL FIRE RESISTANCE DIRECTORY ire APPROVB) The firestopping sealant shall be a water-resistant, intumescent latex sealant The sealant when exposed to high heat or flame shall exhibit a free expansion of up to 8 times its original volume. The firestopping sealant shall contain no water soluble nor hygroscopic ingredients and shall be acoustically tested. The sealant shall be UL Classified and/or FM approved and tested to the requirements of ASTM E814 (UL1479) and shall meet Class A finish requirements when tested in accordance with ASTM E84 (UL723). SPECIFIED DIVISIONS DIV. 7 07840 Through-Penetration Firestopping DIV. 13 13900 Special Construction Fire Suppression & Supervisory Systems DIV. 15 15250 Mechanical Insulation - Fire Protection DIV. 16 16050 Basic Electrical Materials & Methods Technical Service 1-800-992-1180 STI. www.stlfirestop.com 511 Product Data Sheet • Series 1(1 intumescent Sealant • FOD-5062 06/2007 Fig 1: METAWC PIPES- ConcretelMasonry floors & Walls I Fig 2 INSULATED METALUC PIPES -ConcretelMasoniy floors & Wags I Steel Sleeve LCl Sealant Metallic Pip. Metallic Pipe LCI Sealant LCl Sealant Mineral Wool b LCI Sealant Neal leave Concrete Floor __________ Steel' Concrete (Both Sides) Sleeve \ Floor Mineral Wool Mineral Wool Concrete :d teWall •Ifl5uiated Pipe Wall Assembly Metallic Pipe UL System No. C.AJ4353 UL System No. W-J4 098 UL System No. C-Aj-5138 FRatng3lt•TRathg:0it FRtn2HrTRaiin1M,3l4&1Hr FRa1Lig:21tr•rRaling:3f4cr1W Steelorbm l2"CçerPec4" S0cpperPpe<4" Steel ciIran Pe: 9'Ccc4erP4 Nmtajs:0" 102" MaMO" 102" Ppe Cmkg Max T fber s wool pipe iffaL Sealant Dth: 114" Sealaid Duplft 58" MiiAa 114"b 1-518" Sealant II2i Mdoft 1I4"D) Fmriig:Nm4'dwod(3'd0)' Pipe Size Diameter of Opening (In.) 1.5 2.0 3.0 4.0 5.0 6.0 7.0 0.0 10 12 14 26 Trade Pipe Sic. 00. 0.5" 0.840 0.3 0.6 1.8 3.0 4.8 8.9 9.5 12.4 19.5 28.1 38.3 132.6 to' uji Mr Mlat2.5 T Mi*lyEy4 MW Mi4Ly5 1.315 0.1 0.4 1.4 2.8 4.6 6.7 9.3 12.2 19.3 27.9 38.1 132.4 1.5" 1.900 1.1 2.4 4.2 6.4 8.9 11.9 18.9 27.6 37.8 132.0 2.315 0.7 2.0 3.8 6.0 8.5 11.5 18.5 27.2 37.4 131.6 2.5" 2.875 0.1 1.5 3.3 5.4 8.0 10.9 18.0 26.7 36.9 131.1 3.500 0.7 2.5 4.7 7.2 10.2 17.2 25.9 36.1 130.3 6" 6.625 1.1 4.0 11.1 19.7 29.9 124.2 r 0.625 4.9 13.6 23.8 118.0 110..10.750 5.6 15.8 110.0 12" 12.750 6.6 100.8 24" 24.000 19.6 iMP0RTANr NOTE: Thia table is in eslimatan pwposes only. Conajt UL Fn Rcntatance Obactory or Sil Predict & Applicalion Gidde far specific inatalalian reibemwdoañdtjrdistans bleliic Estimation Table avalabie uoon request. Mg. 3: ELECTRICAL, DATA OR COMMUNICAIIONS- Gypsum. Walls Cable LCI Sealant 1[L..:.::i Sealant Bundle (Both Sides) Non- Metallic Conduit Gy sum (Both Sides) GY Assembly Wallboard WaitbsUrnoardTJ i I Assembly UL System No. W-L-3169 UL System No. W-L-2241 F Rating: 1,2Hr•lRaling:'A and V4 F Rating: 1,2Hr.l Rating: 0,V4,1,1.314 Up to 4-1l2cable bundle Rigid PVC or ENV!, CPVC, ASS Annulus: 0-to W•Seaiant 515" Annulus: 0-1 . Sealant 515" TABLE& APPLICATIONS -TESTED AND CLASSIFIED FOR FIRE RESISTANCE Metallic Pipes including steel, iron, or copper pipe and tubing. Nonmetallic Pipes, Conduits & Tubing including PVC, CPVC, ABS, and PEX. Electrical & Electronic Cabling including service entrance, power distribution, computer, telephone, and television. Metal Ductwork including HVAC, bath and dryer vents. Insulated Pipes including heating, cooling, and condensadon applications. Complete Wood Floor firestopping package for electrical, plumbing, HVAC, telephone, and television. 2 511 Product Data Sheet • Series La Intumescent Sealant • FOD-5062 06/2007 Technical Service 1-800-992-1180 www.stiiirestop.com STI. - LCI Sealant Metallic Pipe., INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation temperatures must be between 35°F (2°C) and 100°F (38°C). Allow product to dry a minimum of 24 hours before exposure to moisture. SYSTEM SELECTION: Selection of an appropriate firestop system design is critical to the fire protection process. Space limitations preclude highly detailed information pertaining to individual application systems. Please consult the Product & Application Guide as well as the UL® Fire Resistance Directory for additional information. FORMING: Some installations may require forming as either an integral part of the system or as an option to facilitate installation. In systems where forming is required, mineral wool batts with a minimum nominal density of 4 PCF (64 kg/M3) are generally required. Cut forming material oversize to allow for tight packing. Position forming material to allow for the proper depth of fill material. FILL MATERIAL: SpecSeal® LCI Sealant may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun, or by manually troweling using a mason's trowel or putty knife. If the sealant tends to pull back from a surface, clean the surface with a damp rag or sponge and reapply. Work sealant into all areas exercising care to eliminate voids or seams. The surface of the sealant can be smoothed using a putty knife dipped in water. Adding water to the sealant itself is not recommended. Sealant (when dry) may be painted using most non-solvent based paints. I Fig. 4. BARE & K4SULATEDMEALLIC PIPES-Wood Floor Assemblies I UL System NO. F-C-5043 F Rating: 1 & 2 Hr • T Rating: V4 and 1 Hr Steel, Iron or Copper 4 Pipe covering: 1 Fiber Glass, Mineral fiber or AB/PVC • Chase wall optional. Annulus: 0t0 1• Sealant: 5/8 bottom, ~t0p. In gypsum wallboard penetrations, apply a minimum cove bead of 1/4' (6 mm) at the interface of the penetrant with both exterior wall surfaces. SMOKE SEALING: In some applications including firestop collars, SpecSeal® LCI Sealant is recommended as a smoke seal It is suggested in these applications that the sealant be applied to both sides of walls. In floor applications, a sealing bead is suggested top and bottom. LIMITATIONS: SpecSeal® LCI Sealant is water- based and cures through the evaporation of water. Low temperatures as well as high humidity may retard drying. Non-porous or impermeable backing materials, plates, or coatings may retard the drying process. Do not paint or seal in any way that pre- vents contact with air until sealant has dried through completely. This product has been designed to be safe with plastics and has been used extensively and successfully with a variety of different types of plastic pipes, tubes, and plastic cable insulations. Variations in these materials however, make it impossible to guarantee compatibility. STI strongly recommends that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this product. Wood Floor Assembly UL System No. F-C-I 074 F Rating: 1 &2Hr.T Rating: '/4,t and 1 Hr Steel, Iron or Copper: 4• Chase wall optional. Annulus: 0t0 1. Sealant 518Th0tt0m, 3/4-top Fig. 5: BARE & INSULATED METALLIC PIPES- Gypsum Walls I Metallic III I'' LCI Sealant II (Both Sides) Insulated Metallic LCI Sealant (Both Sides) Gy sum..4ft" Ill AC Line Set Walrboard iii Assembly III JJJJJJ Assembly UL System No. W-L-I 222 F Rating: 1,2Hr.T Rating: V4,114,1 Hr Steel or Iron pipe: 8 Copper pipe: 4 Annulus: 0t0 2• Sealant: 5/8 Assembly Jjj_jjj_ UL System Nos. W-L-5121, W-L-5122 F Rating: 1,2 Hr • I Rating: 1 Hr & 1/4 Hr Steel or Iron pipe: 6 Copper pipe: 4 Pipe covering: Max. 2- fiber glass, V4AB/PVC or 2- mineral fiber Annulus: 0-to 1-1/2• Sealant: 5/8 UL System No. W-L-8025 F Rating: 1.2 Hr • I Rating: 'A Hr AC Line Set: Two copper tubes, one with V4-AB/PVC and thermostat wire Annulus: 0t0 1' Sealant 5/8 Technical Service 1800-992-1180 511 Product Data Sheet • Series 1(1 Intumescent Sealant • FOD-5062 06/2007 www.stifirestop.com 1 .•-.- . _.._ CAT. NO. DESCRIPTION LCI300 Sealant 10.1 oz Tube 18.2 Cu In (300 ml) LC1305 Sealant 5 Gal Pail 1,155 Cu In (19.0 Liters) LC1320 Sealant 20 oz Sausage 36 Cu in. (592 ml) LC1329 Sealant 29 oz Quart Tube 52 Cu in. (858 ml) ..• MAINTENANCE No maintenance is normally required, however a periodic inspection of rated barriers is recommended to make sure that any new openings, modifications of previously installed firestops, or areas exhibiting physical damage, have been properly sealed or repaired. Subsequent sealing or repairs should be accomplished using SpecSeal® products per the original approved design. RETROFIT: When adding or removing penetrants, care should be taken to minimize damage to the seal Reseal using SpecSeal® products per the approved design. NOTE: New penetrants of a different nature than the original design may require a totally new firestop design or extensive modifications to the existing design. Reseal all openings as per the requirements of the modified design. TECHNICAL SERVICE Specified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available through the Technical Library at www.atifirnntnpcnm. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional information on the safe handling and disposal of this material AVAILABILITY SpecSeal® Series LCI Sealant is available from authorized STI distributors. Consult factory or website for the names and locations of the nearest sales representatives or distributors. SedesSsSSealaid The industry's most versatile sealant provides the tirestopping solutions for a wide range 01 combustible and noncombustible applications. Water-based Intumescent sealant expands up to ext humescelt"apstrips Three grades of intumescent wrap strips provide an unmatched combination 01 flexibility, economy, and expansion (up to 30X). Systems for plastic pipes including FR Polypropylene up to B' trade size! SSC&LCCFIrealcpCcrs Easy to install, economical protection for ABS and PVC pipes moth solid and loam core) as well as CPVC, PVDF, and FRPP. ICC Collars are available up to 4' and SSC Collars are avail. able up toll' trade size. Firestop Mortar Lightweight, versatile and economical! The best choice for large or complex installations. SSP Firestop Putty Available both In bar firm and in pads, putty provides easy retrofit for through-penetrations and economical protection for electrical boxes. PenslltS) Silicones Sealants and loam for through-penetrations and construction joints. Unexcelled aging charac- teristics and lldxibilily. Elastomertc Joint Seals New economical products for sealing construction joints. Choose caulk or spray applied products tested to U12079. -- - - - CITY OF NEW YORK MEA 211-01-M IMPORTANT NOTICE: All statements, technical informwion, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not guaranteed WARRANTY Specified Technologies Ina manufactures its goods in a manner to be free of defects. Should any defect occur inks goods (within one year), Specified Technologies Inc., upon prompt notification, will at its option, exchange or repair the goods or refund the purchase puce. LIMITATIONS AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE. No statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and manufacturer. MADE IN THE USA - COPYRIGHT © 2008 SPECIFIED TECHNOLOGIES, INC. gg Specified Technologies Inc. 200 Evans Way' Somerville, NJ 08876 I Toll Free: 800-992-1180 • F: 908.526.9623 4 S11 Product Data Sheet • Series LCI Intumescent Sealant • FOD-5062 06/2007 Technical Service 1800992-1180 9d www.stwirestop.com Sli. '-'•-"H'•Y '-- -, r .- '- " Guide XHEZ (W-L-1222 - B Card) Through-Penetration Firestop Systems (Cont'd from W-L-1222 - A Card) System No. W-L-1222 October 04, 2000 F Ratings - I and 2 Hr (See Item 1) T Ratings - 1/4, 3/4 and 1 Hr (See Item 2) 1. Wall Assembly - The I or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be mm 3-5/8 in. wide and spaced max 24 in. OC. Gypsum Board* - Thickness, type, number of layers and fasteners as specified in the individual Wall and Partition Design. Max diam of opening is 10-5/8 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant - One metallic pipe, conduit or tube to be installed eccentrically or concentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min a in. (point contact) to max 2 in. Pipe, conduit or tube to be rigidly supported on both sides of the wall assembly. The following types and sizes of metallic pipes, conduits and tubes may be used: Steel Pipe - Nom 8 in. diam (or smaller) Schedule 5 (or heavier) steel pipe. Iron Pipe - Nom 8 in. diam (or smaller) cast or ductile iron pipe. Conduit - Nom 6 in. diam (or smaller) rigid steel conduit, nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT) or nom 4 in. diam (or smaller) flexible steel conduit. Copper Pipe - Nom 4 in. diam (or.smaller) Regular (or heavier) copper pipe. Copper Tube - Nom 4 in. diam (or smaller) Type L (or heavier) copper tube. Type of Penetrant Max Diam T Rating Steel or iron pipe, steel conduit or EMT 2 in. 1 hr Steel or iron pipe, steel conduit or EMT 8 in. 3/4 hr Copper pipe or tube 4 in. 1/4 hr 2A. Through Penetrating Product* - Flexible Metal Piping - As an alternate to Item 2, one nom 1-1/4 in. diam (or smaller) steel flexible metal pipe to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe and the periphery of the opening shall be min 0 in. (point contact) to max 2 in. Pipe to be rigidly supported on both sides of the wall assembly. OMEGA FLEX INC TITEFLEX CORP ABUNDYCO WARD MFG INC 3. Fill, Void or Cavity Material* - Sealant - Mm 518 in. thickness of fill material applied within annulus, flush with both surfaces of wall assembly. At point contact location, mm 114 in. diam bead of fill material applied at metallic pipe/gypsum board interface on both surfaces of wall. SPECIFIED TECHNOLOGIES INC - SpecSeal LCI Sealant *Bearing the UL Classification Marking Guide XHEZ October 04, 2000 Through-Penetration Firestop Systems W-L-1222 - A Card System No. W-L-1222 F Ratings - I and 2 Hr (See Item 1) T Ratings - 1/4, 3/4 and 1.Hr (See Item 2) "A Section A-A (Cont'd on W-L-1222 - B Card) Guide XHEZ (C-AJ-1 354 - B Card) Through-Penetration Firestop Systems (Cont'd from C-AJ-1 354 - A Card) System No. C-AJ-1353 November 30, 2001 F Rating - 3 Hr T Rating —0 Hr 1. Floor or Wall Assembly - Mm 2-1/2 in. thick reinforced lightweight or normal weight (100- 150 pcf) concrete floor. Floor may also be constructed of any min 6 in. thick hollow-core Precast Concrete Units*. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 10 in. Max diam of opening in floors constructed of hollow- core is 7 in. See Concrete Blocks (CAZT) or Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2. Steel Sleeve - (Optional) - Nom 10 in. diam (or smaller) Schedule 10 (or heavier) steel pipe cast or grouted into floor or wall assembly. Steel sleeve may be installed flush or may project a max 2 in. beyond the floor or wall surfaces. 3. Through Penetrant - One metallic pipe, conduit or tube to be installed eccentrically or concentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (point contact) to max 2 in. Pipe, conduit or tube to be rigidly supported on both sides of the floor or wall assembly. The following types and sizes of metallic pipes, conduits and tubes may be used: Steel Pipe - Nom 12 in. diam (or smaller) Schedule 5 (or heavier) steel pipe. Iron Pipe - Nom 12 in. diam (or smaller) cast or ductile iron pipe. Conduit - Nom 6 in. diam (or smaller) rigid steel conduit, nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT) or nom 4 in. diam (or smaller) flexible steel conduit. Copper Pipe - Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. Copper Tube - Nom 4 in. diam (or smaller) Regular L (or heavier) copper tube. 3A. Through Penetrating Product* - Flexible Metal Piping - As an alternate to Item 3, one nom 2 in. diam (or smaller) flexible steel pipe to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (point contact) to max 2 in. Pipe to be rigidly supported on both sides of the floor or wall assembly. Omega Flex Inc Titeflex Corp A Bundy Co Ward Mfg Inc 4. Firestop System - The firestop system shall consist of the following: Packing Material - Min 4 pcf mineral wool baft insulation compressed and tightly packed to mm 2-1/4 in. thickness. Packing material recessed from top surface of floor or both surfaces of wall as required to accommodate fill material (Item 413). In floors constructed of hollow-core precast concrete units, packing material to be recessed from both top and bottom surfaces of floor, as required to accommodate fill material (Item 413). When steel sleeve projects from top of floor or from both sides of wall, the thickness of mineral wool batt packing material should be increased by an amount equal to the distance that the sleeve extends past the floor or wall surface. Fill, Void or Cavity Material*_ Sealant - Mm 1/4 in. thickness of fill material applied within annulus, flush with top surface of floor assembly or top edge of steel sleeve. In walls, mm 1/4 in. thickness of fill material applied flush with both surfaces of wall assembly or both ends of steel sleeve. In floors constructed of hollow-core precast concrete units, fill material installed symmetrically on both side of floor. At point contact location, apply mm 1/4 in. diam bead of fill material at pipe/concrete interface or pipe/steel sleeve interface on top surface of floor or both surfaces of wall or precast concrete units. Specified Technologies Inc - SpecSeal LCI Sealant rim Guide XHEZ November 30, 2001 Through-Penetration Firestop Systems C-AJ-1 353-A Card System No. C-AJ-1353 F Rating -2Hr T Rating -0Hr V, Section A-A (Cont. on C-AJ-1 353-B Card) :