Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6125 PASEO DEL NORTE; ; FPC2017-0003; Permit
PERMIT REPORT city of C arlsbad Print Date: 02/15/2024 Job Address: 6125 PASEO DEL NORTE, CARLSBAD, CA 92011-1117 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2017-0003 Status: Closed - Finaled Applied: 01/05/2017 Issued: 01/24/2017 Finaled Close Out: 03/10/2021 Final Inspection: INSPECTOR: Wong, Cindy Fieri, Dominic Project Title: Description: PASEO DEL NORTE SHELL & CORE -FIRE ALARM FPContractor: THE STEINHILBER CORPORATION 5335 VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Irmfil EHvEpppwEs FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS PASEO DEL NORTE LLC SHELL & CORE 6125 PASEO DEL NORTE CARLSBAD, CA 92011 FIRE ALARM SYSTEM MATERIAL DATA SHEETS BILL OF MATERIALS NOTIFIER NFW2-100 FIRE ALARM CONTROL PANEL CSFM# 7165-0028:0235 DMP SLCF COMMERCIAL WIRELESS FIRE COMMUNICATOR CSFM# 7300-1157:0136 NOTIFIER N-ANN-80 REMOTE FIRE ANNUNCIATOR CSFM# 7120-0028:0240 NOTIFIER NOT-BG12LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:0199 NOTIFIER NP-100 ADDRESSABLE SMOKE DETECTOR CSFM# 7272-0028:0231 NOTIFIER NH-100 ADDRESSABLE HEAT DETECTOR CSFM# 7270-0028:0234 NOTIFIER 302 SERIES RATE ANTICIPATION HEAT DETECTOR(WEATHERPROOF) CSFM# 7270-0021:0001 NOTIFIER NMM-100P ADDRESSABLE MONITOR MODULE CSFM# 7300-0028:0230 NOTIFIER NC-100R ADDRESSABLE RELAY MODULE CSFM# 7300-0028:0230 SYSTEM SENSOR PC2W HORN/STROBE, SELECTABLE CANDELA - CEILING MOUNTED CSFM# 7125-1653:0188 SYSTEM SENSOR P2RK HORN/STROBE - OUTDOOR WALL MOUNTED CSFM# 7125-1653:0188 DN-60602:A1 FireWarden-100.2(E) Rev 3 NOTI Fl ER® Intelligent Addressable FACP 00 by Hon eywell The Notifier FireWarden-100-2 Rev 3 (NFW2-1 00) with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the Fire Warden-1 00-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The 's quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS, and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local pro- gramming of the control panel using the PS-Tools Upload/Down- load utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows® XP or greater, a com- patible modem, and PS-Tools—the Upload/Download software kit—may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, NP-A100, USB port, NAC circuit diag- nostics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for NFV-25/50ZST, Photo Supervisory and auto-reset- table Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term "Fire Warden-100-2" is used in this document to refer to both the Fire Warden-100-2 and the Fire Warden-100-2E FACPs (Fire Alarm Control Panels). Like- wise, "NFW2400" refers to NFW2-100E as well. Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four (4) Style V (Class B) NAC: circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM•.24B.) Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or FDU-80, N-ANN-80 or Legacy ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - N-ANN-80(-W) Remote LCD Annunciator - N-ANN-I/O LED Driver - N-ANN-S/PG Printer Module - N-ANN-RLY Relay Module - N-ANN-LED Annunciator Module - N-ANN-RLED Annunciator Module alarms only - ROME Relay Option Module Enclosure ACS & Terminal-mode Annunciators: - ACS Annunciators: Up to 32 Legacy ACM Series annuncia- tors (ACM-i 6AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. - Terminal-mode Annunciators: Up to 32 Legacy FDU-80 annunciators. EIA-232 printer/PC interface (variable baud rate) on main cir- cuit board, for use with optional JL-listed printer PAN-6. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). 0N.6062:A1 • 12/07/2010 - Page 1 of 6 History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accumu- lation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using out- put control modules (NC-100). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-1 00 requires PS-Tools Programming software, avail- able on www.magni-fire.com). Upload/download system pro- gramming locally to the NFW2-100 Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information NFW2-100: FireWarden-100-2 Rev 3 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. NFW2-100R: Same as NFW2-100, exceptin a red backbox. NFW2-100E: Same as NFW2-100, except with 240 VAC opera- tion. 4XTM Reverse Polarity Transmitter Module: Provides super- vised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style V (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PS Tools: Programming software for Windows®-based PC computer (cable not included), available on www.firelite.com. DP-9692B: Optional dress panel for FireWarden-100-2 Rev 3. TR-CE-B: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid batter- ies with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E Rev 3. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download program- ming and updating panel firmware. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DN-60408 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; see DN-7114.) Page 2 of 6— DN-60602:AI • 12/07/2010 N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DN- 7107.) ROME-B: Relay Option Module Enclosure (order ROME-13 for black or ROME for red). Provides one N-ANN-RLY Relay Mod- ule already installed. The ROME Series provides mounting space for one additional Relay Module or one addressable Multi- module. (See Installation Sheet PN 53530.) N-ANN-SIPG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LOM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-char- acter, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets (document numbers) ACM-81? (DN-3558), ACS/ACM Series (DN- 0524), LDM Series (DN-0551), FDU-80 (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-lOOT: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-iOOR: Addressable remote test capable detector for use with DNR(W) duct smoke detector housings. NH-1 00: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190 F/88C. NP-A100: Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order NP-1 OOR separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) bC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only lDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style V/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0' (10.16 cm.) box, surface mount using the SM13500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: .Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 oper- ation). SMB500: Used to mount all modules except the NMM-100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-25. NZM-100-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS.6 chassis in a BB-25. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-100-2 Rev 3, see the following data sheets (document numbers): N100-ISO (DN-6994), NP-100 series (DN-6995), NI-100 (DN-6996), NH-100 series (DN-6997), ND-100 series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-I00P/ NDM-100/NZM-100 (DN-6999), NC-100/NC-IOOR (DN-7000), NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- 100-6 (DN-60150). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. DN.60602:A1 • 12/07/2010 - Page 3 of 6 Fire Warden-I 00-2 Rev 3 Fire Alarm Control! Communicator ANN-BUS DEVICES N-ANN-80, N-ANN-LED, N-ANN-S/PG, N-ANN-I/O 24VDC IEEE ANNUNCIATORS ACS/ACM, LDM NOTE: System can use either ANN-BUS devices OR ACS-mode annunciators. They cannot be used simultaneously. ANN-BUS or EIA-485 in ACS mode (two wires) Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTM) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-811) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES EIA-232 INTERFACE (PIM-24) built into the motherboard SMOKE DETECTORS NP-100, NP-100T, NI-100, NP-A100 HEAT DETECTORS NH-1100, NH-100R, NH-100H DUCT DETECTORS ND-100, ND-100R, DNR —+ E MONITORICONTROL NMM-100, NZM-100, NDM-100, N100-ISO, NC-100, NC-bOOR 0 Ii ii I I I I 00000l Q_e 0 0 0 ADD; ABLE MULTI-MODULE NZM-100-6, NMM-100-10 EIA-485 INTERFACE (four wires) NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously. 24VDC R MINI-MONITOR NMM-1 OOP II I1I 0 010 FDU-80 Up to 6,000 ft. (1825.8 m) between each FDU-80 in the EIA-485 loop, and between each FDU-80 and the FACP. t] PULL STATION NOT-BGI2LX Page 4 of 6— DN-60602:A1 • 12/07/2010 ON-60602:A1 • 12/0712010— Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.........................................1 Addressable device capacity............................................198 Programmable software zones...........................................99 ACS Annunciators ..............................................................32 ANN-bus devices................................................................16 Electrical Specifications AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2 Rev 3(E): 240 VAC, 50Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH- 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batter- ies require an external battery charger such as the CHG-75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block provides connections for two Style V (Class B) for a total of four Style V (Class B) or with an optional ZNAC-92 module converts to four Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to panel documenta- tion and Notifier Device Compatibility Document for listed com- patible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps 0 30 VDC (resistive), 0.5 amps 0 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each out- put. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a minimum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65' (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR.CE- B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.6'(21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93%:t 2% RI-I (non- condensing) at 32°C * 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. NFPA Standards The FireWarden-100-2 Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100-2 Rev 3 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 FM approved CSFM: 7165-0028:0235 MEA: 120-06-E, Volume 2 For ULC-Iisted version, see DN-60600. NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and ExcederTM is a trademark of Cooper Notification. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. !'fl We cannot cover all specific applications or anticipate all requirements. U I MUNEBlN IMANOUCTOUNt All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6 of 6— DN-60602:A1 ° 12/07/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM t9 LISTING No. 7165-0028:0235 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models Fire Warden 100 and Fire Warden 100-2 addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). This panel also can be used with NFV-25/50ZST (Fire Voice-25/-50ZST) Zoned System Voice with Telephone for Emergency Voice evacuation Applications. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Fire Warden 100-2 panel also suitable for high-rise application for use with Model NFC-50/100 emergency voice evacuation panel (CSFM # 6911-0028:0265). This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:0208 *Rev. 11-15.13 GT This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 -• Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Add cellular communications to any panel Extend the life and expand the capabilities of older panels by adding the power of advanced. digital cellular communication. With this simple communications add-on, almost every panel can take advantage of revenue-building remote system management and control features. Provide central station communication over cell for any burglary commercial fire or residential fire panel Use Contact ID capture. 4 zones, or Bell Monitoring CeLlComSLCTM and CellComSLCF enables basic remote panel control via Virtual Keypad AppTM Provides end user alerts of arming/ disarming, alarm, and other events Add Z-Wave control of lights, locks, and thermostats with CellComSLCZTM CLLLCOS L SERIES NSA ALARM COILCATO SYSTEM FEATURES Fully supervised universal alarm communication over COMA Fully supervised universal fire alarm communication over COMA Program your own account number to easily workaround locked panels Contact ID dialer capture Four zones or Bell Monitoring Wiring for Ademco ECP Bus Communicates with OMP SCS-1 Rand SCS-VR Receivers Builds customer loyalty: creates new RMR Armed/disarmed status LED Private labeling available on the rubber logo insert ' Two outputs C - -- -- - - - r =0 RKS WITH MOST PANELS If the existing panel supports Contact ID, then it's a candidate for upgrading with the CellComSLC. CellComSLCZ. or CellComSLCF. There are no issues with lockout codes. Simply add the CelLComSL unit to the existing installation and program in your own account number. AVAILABLE BURGLARY COMMUNICATION The CellComSLC provides control of basic panel security functions and video. The CellComSLCZ adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats and more. FIRE COMMUNICATION The CellComSLCF offers cellular fire communication on any fire control panel via Contact ID Captures or Zone Inputs. Meets NFPA 72 Standard for Single Communication Technology. MOBILE SYSTEM CONTROL With CellComSL communicators you can easily update your older residential and commercial customers to the latest cellular communication links. With cellular in place. end users can remotely access their panels via the Virtual Keypad AppTM. This makes it possible to use their mobile device not only to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices for lights, door locks. thermostats, and more with CellComSLCZ. ENABLE VIDEO ON THE APP Video is no longer an expensive option. With the CellComSLC communicators, you can easily add up to six wireless cameras. Via the Virtual Keypad App, end users can do a remote visual survey of their premises to confirm an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION Provides a fully supervised alarm communication path for burglary control panels over the COMA network providing higher speeds. CellComSL allows alarm messages to be communicated to an SCS-1 R or SCS-VR Receiver over the CDMA network. CDMA operates on the Verizon network. FIELD PANEL UPDATES The Model 400 USB Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. SYSTEM PROGRAMMING System programming over cell via VirtualLinkTM includes zone information and Central Station communications. MULTIPLE CONNECTION OPTIONS CellComSL communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer, or connect the four input zones from outputs on the panel: or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the Central Station. FOUR ZONES Each of the CellComSL models provide four zones for connection to burglary control panel outputs. Zone le is intended for connection to the control panel bell output. EASY UPGRADE FOR DIALER- ONLY PANELS Older, dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels, enabling them to increase the ROI on their system investment and build satisfaction with the purchase decision. BUILD CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel their contract. When the time does come to replace the panel, they are more likely to rely on you. The app can be branded with your organization's logo and contact information to provide a daily reminder of your services. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel 12 via the App. 0 C" CERTIFICATIONS California State Fire Marshal (CSF ANSI/UL 1610 Central Station Bur ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire War ANSI/UL 864 Fire Protective Sign Cellular FCC Part 15: MIVCNNO3O CellComSL FCC Part 15 ID: CCKPCO1 IC: 5251APcO159 SPECIFICATIONS Dimensions: 5.5' W x 3.75' H x 1" D Color: White Open-Collector Outputs: 2 Zones: 4 Primary Power (CellComSLC/SLCZ): 12VDC Primary Power (CellComSLCF): 1224V0C Current Draw: Alarm 210 mA Standby 210 mA ORDERING INFORMATION CellComSLC Universal Alarm Communicator ------_...... CellComSLCF Universal Fire Alarm Communicator Alarm Communicator. Z-Wave M) glar Li (Cellular) ning (CID Capture) aling Systems Th C 2 0 59 Si In 0 --- -, 2500 North Partnership Boulevard 800.641.4282 dmp.com Springfield. Missouri 65803-8877 Designed. Engineered & Manufactured in Springfield. Missouri CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM t9 LISTING No. 7300-1157:0136 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton©dmp.com DESIGN: Models CellComSLC, CellComSLCZ, *CeIIComSLCF* iComSLF, iCOMSL and iComSLZ Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and ETL label. APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. Rev. 07-14.15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 -. Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division dn-7114:c • A1-65 CO)NOTIFIER 0 Serial Annunciator by Honeywell General N-ANN.80 80-Character LCD The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-805 may be connected to the ANN-BUS of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACP5 with an ANN-BUS, such as the NFW-50. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence. Drill, and Reset. Control switches can be independently enabled or disabled at the FACR Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACR N-ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4 square electrical box. Use ANN-5B80K1T for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight N-ANN-80s can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption 0 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 490C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors In a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the N-ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7120-0028:240 MEA: 442-06-E Vol. 2 The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. dn-7114:c • 5/22/09 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-BUS communica- tions circuit. To determine the type of wire and the maximum wir- ing distance that can be used with FACP ANN-BUS accessory modules it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance Is the limiting factor. These cases are marked In the chart with an asterisk (). Maxi- mum length can never be more than 6,000 feet (1800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. All connections are power-limited and supervised. A maximum of eight N-ANN-80 modules may be connected to this circuit Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. 6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563ft. 2,488 ft. 3,937 ft. 0.400 4631t. 1,172 ft. 1,866 ft. 2.953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. ORDERING OPTIONS: N-ANN-SO: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. --l- ANN-BUS Device NFW-50 12345678 FACP Wiring to ANN-BUS Device ANN-BUS and power wiring are supervised and power-limited. ANN-SB8OKIT-B: Black surface mount backbox with angled wedge. ANN-SBBOKIT-W: White surface mount backbox with angled wedge. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information upto-date and accurate. We cannot cover all specific applications or anticipate all requirements. BSINEERINI A MANIFF1113111111111 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-7114:c • 5/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:0240 Page 1 of I CATEGORY: 7120— ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Nrthford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models N-ANN-80 and *N_ANN..80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. XLF: 7120-0075:0211 Rev 12.11-14gt .9 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NOT-BG I 2LX Addressable Manual Pull Station DN-7001:D • Al-380 NOTIFIER .!1 : [i111A'iTk] I Intelligent/Addressable Devices The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG1 2LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches In down position and the word ACTIVATED' appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/o) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4(10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4° (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The NOT-BGI2LX Addressable Manual Pull Station The BG12TR is usually needed for semi-flush mounting with 4° (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4 (10.16 cm) square electrical box, and shall be installed DN-7001:1) ° 4/1312012— Page 1 012 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG1 2LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E Vol. IV. CSFM: 7150-0028:0199. FM Approved. Patented: U.S. Patent No. D428,351; 6.380,846; 6,314,772; 6.632,108. NOTIFIER® is a registered trademark of Honeywell International Inc. @2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. M$lNfHllN MANUFIItIUMNG All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 2 of 2— DN-7001:13 • 4/1312012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM PJ LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of 1 CATEGORY: 7150- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-I2LAO, NBG-12LAOB, NBG-12-LO, NBG-I2LOB, NBG-12W, NBG-I2LW, NBG-I2NC, NBG-I2WP, NBG-I2LWP, NBG-12L, NBG-12LX, NBG-I2LA, NBG-12P5, NBG-I2LSP, NBG-I2LPS, NBG-I2LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-I2LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-12LW, NBG-12W, NBG-I2LWP, NBG-I2LAO, NBG-12L0, NBG-I2LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 5lbs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh 'N • This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6995:D • Al -320 NP-100(A) Series NOTI Fl ER® Addressable Photoelectric Detectors by Honeywell Addressable r Devicesi General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (Fire Warden-i 00-2 and Fire Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACP5). The NP-100T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (570C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory, PN RA1 OOZ(A). The NP-i OOR(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detec- tor housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: 01 - 99 with FireWarden-100-2 and NSP-25, and 01 —50 with FireWarden-50. ARCHITECTURE Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communicat- ing with the fire panel) and latches on in alarm. MECHANICALS Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). OTHER SYSTEM FEATURES Fully coated circuit boards and superior RF/transient protec- tion. 94-VO plastic flammability rating. Low standby current. -' - NP-1100(A) in B2IOLP(A) Base OPTIONS Remote LED output connection, PN RA100Z(A). Applications Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, especially where smol- dering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. NP-100(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation NP-100(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5° (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class B) wiring. NP-10013(A) mounts in a DNR(A)/DNRW duct detector housing. Operation Each NP-100(A) series detector uses one of 99 possible addresses on the FireWarden-100-2 and NSP-25, or one of 50 possible addresses on the FireWarden-50 Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the NP-100(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the NP-100(A) series is approximately two times more respon- sive than most photoelectric sensors. This makes it a more sta- ble detector. DN-6995:D • 2/11/2015 - Page 1 of 2 L Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a FireWarden-100-2 or FireWarden-50 addressable fire alarm control panel. The results of the sensitiv- ity test can be printed off the FireWarden-100-2 or FireWarden- 50 for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 300 pA 0 24 VDC. LED current: 6.5 mA 0 24 VDC (latched "ON"). Air velocity: 4,000 ft./min. (20 rn/sec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. - 821 OLP(A): 6.1" (15.5 cm) diameter. - 8501(A): 4.1" (10.4 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - 8224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100(A): 0°C to 49°C (32°F to 1200F); for NP-100T(A): 0°C to 38°C (32°F to 100°F). NP-IOOR(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the NP-100(A), NP- IOOT(A), and NP-100R(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing status. UL Listed: S1 115. ULC Listed: S1115. CSFM: 7272-0028:0231. MEA: 243-02-E Vol. 2. Maryland State Fire Marshal: permit 2173. FM approved. Product Line Information NOTE: "A" suffix indicates ULC Listed model. NP-100: Addressable photoelectric detector; B21OLP base included. NP-100A: Sames as NP-100 with ULC Listing; B21OLPA base included. NP-lOOT: Same as NP-1 00 but with thermal element; B21OLP base included. NP-100TA: Same as NP-100T with ULC Listing; B21OLPA base included. NP-lOOR: Remote test capable addressable photoelectric detector for use with a DNRA/DNRW duct detector housing; B21OLP base included. NP-100RA: Same as NP-100R with ULC Listing for use with a DNRA duct detector housing; B21OLPA base included. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B21OLP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A 0 30 VDC resistive; 0.3 A 0 110 VDC inductive; 1.0 A 0 30 VDC inductive. B22481(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. FI10BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-0900: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-2008: Black detector covers for use with NP-100(A) only; box of 10. WCK-200B: White detector covers for use with NP-100(A) only; box of 10. NOTIFIER® and FireWarden® are registered trademarks of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. - We cannot cover all specific applications or anticipate all requirements. GGINHIIita 9 M11011FAMMIN All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6995:1) • 2/1112015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0231 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NP-100, NP100R* and NP-100T photoelectric type smoke detectors. Model NP-lOOT has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. *Models NP-1 00 and NP-100R are also approved for installations inside Notifier duct detector housing ND-200 (OSFM Listing No. 3242-0028:236) and System Sensor duct detector housing DNRW (OSFM Listing No. 3242-1653:210). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:0194 *Rev. 01-27-10 fm This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6997:D • Al-320 (Vt)P NOTIFIER® Detectors for FireWarden Series by Honeywell General NH-100(A) Series Intelliaent Addressable Thermal The NOTIFIER NH-100(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors provide open- area protection and are intended for use with FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25) addressable Fire Alarm Control Panels (FACPs). The NH-100(A) and NH-iOOR(A) sensors provide fixed tem- perature alarm detection at 135°F (570C). The NH-100R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The NH-i OOH(A) is a fixed high-tem- perature detector that activates at 190°F (880C). These ther- mal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory, the RA100Z. Features SLC loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Rotary, decimal addressing: 01 —99 with FireWarden-100- 2, NSP-25, 01 —50 with FireWarden-50. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the NH-100(A) and NH- 100R(A); 190°F (88°C) for the NH-lOOH(A). Rate-of-rise triggers at 15°F (8.3°C) per minute for the NH- 100R(A). 3600-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red In Normal condition and turn on steady red in Alarm. Visible LEDs "blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. NH-100(A) in B210LP(A) Base Low standby current. 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA100Z remote LED annunciator. Flanged surface mounting kit. Installation NH-100(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted fcr Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white fire-resistant plastic. The NH-100(A) Series plug-in intelligent thermal detectors are designed to commercial standards and offer an attractive appearance. Operation Each NH-100(A) Series detector uses one of 99 (FireWarden- 100-2, NSP-25) or 50 (FireWarden-50) possible addresses on a control panel SLC loop. It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), It stimu- lates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The NH-100(A) Series offers features and performance that represent the latest in thermal detector technology. ON-6997:D ° 5/17/13 - Page 1 of 2 Spefications Size: 2.1" (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1° (15.5 cm) diameter. - B501 (A): 4.1° (10.4 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Installation temperature: - NH-100(A), NH-i OOR(A): -4°F to 100°F (-20°C to 380C). - NH-100H(A): -4°F to 150°F (-20°C to 660C). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B21OLP(A) flanged base, included. See "Product Line Information: Intelligent Bases" if using a different base. Fixed-temperature setpoint: 135°F (57°C) for the NH-100 and NH-1 OOR(A)(A); 190°F (88°C) for the NH-1 001-1(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the NH-100(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747. ULC Listed: S747. CSFM: 7270-0028:0234. MEA: 387-02-E Vol. II. FM approved. Product Line Information NOTE: "A" suffix indicates ULC Listed mode!. NH-100: Intelligent thermal sensor; 135° F (57° C); B21OLP base included. NH-100A: Same as NH-100 but with ULC Listing; B21OLPA base included. NH-i OOR: Same as NH-100 with rate-of-rise feature; B21OLP base included. NH-100RA: Same as NH-baR but with ULC Listing; B21OLPA base included. NH-100H: Intelligent fixed high-temperature thermal detector; 190° F (88° C); B21OLP base included. NH-100HA: Same as NH-100H but with ULC Listing; B21OLPA base included. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces 8501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A 0 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between Isolator bases (see DN-6994). ACCESSORIES FilO: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-1 27-010: Detector removal tool without pole. NOTIFIER® and FireWarden® are registered trademarks of Honeywell International Inc. @2013. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO goo Thisdocument is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. - • We cannot cover all specific applications or anticipate all requirements. ENCINELIIINE & MNVFC11IRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2012- DN-6997:13 • 5117/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0234 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models NH-1 00, (fixed temperature) and NH-100R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: NH-100 135° F fixed temperature NH-iOOR 135° F fixed temperature and 15° F rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7270-0075:0195 11.03-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I. dn-1271:A1 '1-307 (9)"I'NOTIFIER. by Aoneywell I I Conventional Initiating Devices Iit1fl I I 302 Series Rate-Anticipation Heat Detectors The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8 (10.48 cm). Base diameter: 2 (5.08 cm). Electrical Ratings Voltaae 6-125VDC Current 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50 x 50' (15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. I271phoI.1pg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-1 35/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 LVER CT POINTS SION STRUTS XPANSION 1G SHELL 0,040 ED ALUMINUM NTICIPATION OL SLEEVE IG SCREW IN HERMETIC SEAL Cut-Away View dn-1271:A1 • 12/23/08 -Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note I below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-1 94 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting KIM below 302-EPM-194 194°F Explosion Proof Mounting AP-P I Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4° outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50'x 50'(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to °THW°or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2° (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 112"(1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. NOTIFIER® is a registered trademark of Honeywell International Inc. @2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 111IlNt5lN 9MNUFA1UNB All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-1 271:A1 • 12/23/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0021:0001 Page 1 of I CATEGORY: 7270 - HEAT DETECTOR LISTEE: Thermotech Inc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AW, 302ET and 302EPM heat detectors. Units are open circuit, 1350 F. 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-El or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F. 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-El and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6999:E Monitor Modules NOTI Fl ER® NMM-1 00(A), NMM.IOOP(A), NZM.1 00(A), and NDM-100(A) for FireWarden Series by Honeywell I OIilc:if3 1c'1 1*i1 General Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- tact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-IOOP(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) 0 that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-1 00P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTm is a communication protocol that greatly increases the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. NMM-1 00(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 99 on FireWarden-100- 2, 01 —50 on FireWarden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used no-n- nno0 TIWnH nnoonun,,roo NMM-100(A) (Type H) to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), I com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM.IOOP(A) Mini Monitor Module ° Built-in type identification automatically identifies this device as a monitor module to the panel. DN-6999:E .07/30/2015—Page lof 4 Powered directly by two-wire SLC loop. No additional Wire length: 6"(15.24 cm) minimum. power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 —99 on FireWarden-100-2, 01 —50 on FireWarden-50. I 1415 0 1 ADDRESS I 0 1 I 1/\2 II —"2 12 3 LOOP 11 I 7 61 8 76 I TENS ONES s:: oil Lu Iio iI -J Lou I j Co .3 II i The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelli- gent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two- wire initiating device circuit for normally-open-contact fire alarm and security devices. NMM-IOOP(A) NMM-IOOP(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NMM-IOOP(A) OPERATION Each NMM-IOOP(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). NMM-IOOP(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, I communication every 5 seconds. 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. NZM.1 00(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address:, 01 —99 on F.ireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It trans- mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and I LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2014— DN-6999:E • 07/30/2015 NDM.100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel. controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address '26°, then it will automati- cally assign itself to addresses "26" and "27°. NOTE: "Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. J& CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-IOOP(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100). MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100). Product Line Information NOTE: "A" suffix indicates ULC-fisted model. NMM-100(A): Monitor module. NMM-IOOP(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SM13500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. DN-6999:E • 07/30/2015 - Page 3014 Notifie,® and FireWarden® are registered trademarks and LiteSpeedTM and FireWatchTm are trademarks of Honeywell International Inc. @2015 by Honeywell International Inc. All lights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MCINEMINS & MNUFRX1URING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6999:E • 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7300-0028:0230 Page 1 of I 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-IOOR and NC-100 control modules; and *NzM..100..6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 'N an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division dn-60383:A2 NC-100R(A) NOTI Fl ER® Relay Module for 0 FireWarden Series Panels by Honeywell General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. E to Features Built-in type identification automatically Identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED 'blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-100-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-100R(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. act.)!) -, ¶1S01 71 a NC-100R(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (UR=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2m5) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2 • 06117/10— Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-I OOR: Intelligent addressable relay module. NC-1 OORA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MCINEERING S MANUFACIUI1INE All specifications are subject to change without notice. QUALITY SYSTEMS Made ln the U.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 012— dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484.7309 Email: vladimir.kireyev@honeyweII.com DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM..100..6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct it operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Indoor Selectable. Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert'' Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95,110,115,135.150,177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MOL3 sync module Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation, SpectrAlert Advance utilizes a universal mounting plate so you can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Aciencv Listincis SIGI1AUNG ®MEA' LISTED APPROVED approved 7125.1653 0186 (indoor strobes) 7125.165301 88 (horn strobes. S401 1(chimes, horn strobes, horns) 3023572 MEA452.05.E Chime strobes) S5512 (strobes) 7135.1653 0189 (horns, chimes) SpectrAlert Advance Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync'Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply, Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1,8-inch back box. The module shalt also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. -Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9' diameter x 3.4' high (175 mm diameter x 86 mm high) (SBBCRSBBCW) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOS1OIO UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (rnA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low Current Draw 132 RMS), 2 154 Horn -Wire Strobe, 80 High Candela 90 105 Range (135-185 cd) 161 184 202 211 UL Max. (mA DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Morn Strobe *UtpUt (00A) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC PAIR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Rt Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low - 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. AVDS1OIO1 a. Ceiling-mount horn strobes Ceiling back box surface mount back box SpectrAlert Advance Dimensions SpectrAlert Advance Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2R 2-Wire Horn Strobe, Standard Cd, Red SCR Strobe, Standard Cd, Red PC2R-P 2-Wire Horn Strobe, Standard Cd, Red, Plain SCRH Strobe, High Cd, Red (no "FIRE") marking SCW Strobe, Standard Cd, White PC2RH 2-Wire Horn Strobe, High Cd, Red SCW-P Strobe, Standard Cd, White, Plain (no "Fire") marking PC2W 2-Wire Horn Strobe, Standard Cd, White SCWH Strobe, High Cd, White PC2W-P 2-Wire Horn Strobe, Standard Cd, White, Plain Accessories (no "FIRE") marking PC2W-SP 2-Wire Horn Strobe, Standard Cd, White, Fuego" marking PC2WH 2-Wire Horn Strobe, High Cd, White PC2WH-P 2-Wire Horn Strobe, High Cd, White, Plain (no "FIRE") marking PC2WI-I-SP 2-Wire Horn Strobe, High Cd, White, "Fuego" PC4R 4-Wire Horn Strobe Standard Cd, Red PC4RH 4-Wire Horn Strobe, High Cd, Red PC4W 4-Wire Horn Strobe, Standard Cd, White SBBCR Surface Mount Back Box, Ceiling, Red SBBCW Surface Mount Back Box, Ceiling, White Notes: All -P models have a plain housing (no FIRE' marking on cover) All -SP models have FUEGO" marking on cover Standard Cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. High cc!" refers to strobes that include 135. 150. 177, and 185 candela settings. S)'STEIIf! 3825 Ohio Avenue • St. Charles, IL 60174 @2OI5SystemSensoi. Product specifications Subject to cfl5500 ,ei9tSut notice. Volt oroenoocom for current product information, including the latest version of this data shoot. SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 AVD510102 • 03/15 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh e This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Agency Listings FM IlIEA it 73001653187 (outdoor strobes) APPROVED approved 7I25.I653188 (horn strobes. chime strobes) 3023572 MEA462-05-E 7135-1653189 (hornS. chimes) SIGNAUNC LISTED S4011 (chImes, horn strobes, corns) S3593 (outdoor and alert strobes) oe F :14112ALTA" SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 151°F Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with %-inch top and bottom conduit entries and 3A-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SYSTEM SENSOR® Outdoor Selectable, Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrA lerP Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products I • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from -40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting .4 SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts: 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobes entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F (-.40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/RNR' Operating Voltage Ran9e2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Wall-Mount Dimensions (including lens) 5.6L x 4.7W x 2.5D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4.7W x 1.3D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7L x 5.1'W x 2.0D (145 mm Lx 130 mm x 51 mm 0) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSO 201 UL Current Draw Data hi_IItlax. btr0be Currentl IrawIII Candela AFTIS) 8-17.5 Volts DC FWR ME 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 tuiu Max. Horn riCurrentiu Draw imyi:i Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 High 135 Candela 150 Range 177 185 UL Max. U ii ii ZI1w!1:h!dtwaI!n NA NA NA NA NA NA NA NA 228 207 246 220 261 251 286 258 St -robe, Coded Coded Range (15-115 cd) Medium Low 44 40 51 56 46 52 69 50 DC Input 8-17.5 Volts 15 15175 16-33 Volts 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output (dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 66 86 96 96 3 Temporal Low 71 73 76 76 83 60 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7t Coded High 82 82 86 88 93 92 101 101 Bt Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDSOITOI A I Strobe (cd) 1T J Listed Candela Candela rating at -40°F 15 15/75 Do not use below 32°F 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHKt 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHKt 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) - P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK"t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWKt Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box V Notes: Add "-P' to model number for plain housing (no "FIRE" marking on cover). e.g., P2RK-P. t Add "-fl" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate. WTP and WTPW. "Standard cd' refers to strobes that include 15. 15/75,30,75,95. 110. and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177. and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. "\ 3625 Ohio Avenue • St. Charles, IL 60174 . 02012 System Sensor. Product spocif cat ens subject to change wtiirout notice. Visit syatemsensor.com .$ SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 for Cwroflt Potdacli5fwrnattafl, 10chrd109 the least vorrionol this data sheel AVDS0120I • 3112 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as "horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes" can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct elv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator - Fire Engineering Division