6359 PASEO DEL LAGO; A; FPC2018-0153; Permit
(it"? yof PERMIT REPORT Carlsbad Print Date: 02/15/2024 Permit No: FPC2018-0153 Job Address: 6359 PASEO DEL LAGO, # A, CARLSBAD, CA 92011-1317 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2130920900 Track U: Applied: 05/15/2018 Valuation: $77,532.17 Lot #: Issued: 12/14/2018 Occupancy Group: Project #: Finaled Close Out: 05/07/2019 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check U: INSPECTOR: Wong, Cindy Plan Check #: Project Title: Description: FASHIONPHILE MEZZANINE -SPRINKLER TI (10 HEADS) Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 S MELROSE PL, U 244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov f~'Ojr-"2-oU - o i(~; 3 Fire Protection by Computer Design TOTAL FIRE PROTECTION SAN MARCOS, CA 760-525-4329 Job Name : FASHIONPHILE MEZZANINE Building Location : LOWER MEZZ System Contract Data File : F-PHILE CALCS.WXF TOTAL FIRE PROTECTION FASHIONPHILE MEZZANINE HYDRAULIC CALCULATIONS for Project name: FASHIONPHI LE MEZZANINE Location: LOWER MEZZ Drawing no: Date: 5/9/18 Design Remote area number: Remote area location: Occupancy classification: ORD GRP II Density: .20 - Gpm/SqFt Area of application: ENTIRE AREA - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: TYCO TV-B (TY315) No. of sprinklers calculated: 8 In-rack demand: - GPM Hose streams: 250 - GPM Total water required (including hose streams): 475.663 -GPM © 60.59 -Psi Type of system: Volume of dry orpreaction system: -Gal Water supply information Date: 4/26/18 Location: SOUTH END OF PASEO DEL LAGO Source: CARLSBAD WATER DISTRICT Name of contractor: TOTAL FIRE PROTECTION Address: . /. I SAN MARCOS, CA Phone number: 760-525-4329 Name of designer: JB Authority having jurisdiction: CARLSBAD FIRE Notes: (Include peaking information or gridded systems here.) + 6.20 SAFETY Page 1 Date 5/9/18 City Water Supply: Cl - Static Pressure : 67.5 C2 - Residual Pressure: 55.5 C2 - Residual Flow : 2200 Demand: Dl - Elevation : 3.967 D2 - System Flow : 225.663 D2 - System Pressure : 60.590 Hose ( Demand) : 250 D3 - System Demand : 475.663 Safety Margin : 6.204 vvater z>upF - urve TOTAL FIRE PROTECTION Page 2 FASHIONPHILE MEZZANINE Date 5/9/18 150 140 130 P 120 R 110 E 100 S90 S 80 U 70 R 60 E 50 40 30 20 10 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (NA 1.85) 1-ittlngs USE ummary TOTAL FIRE PROTECTION Page 3 I FASHIONPHILE MEZZANINE Date 5/9/18 Fitting Legend Abbrev. Name 1/2 % 1 Vh 1% 2 2% 3 3Y2 4 5 6 8 10 12 14 16 18 20 24 B NFPA13ButterflyValve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 I NFPA 1390FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Pressure I Flow Summary - STANDARD TOTAL FIRE PROTECTION Page 4 FASHIONPHILE MEZZANINE Date 5/9/18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 9.16 5.6 21.56 na 26.0 0.2 130 7.0 2 9.16 5.6 23.91 na 27.38 0.2 130 7.0 3 9.16 5.6 25.79 na 28.44 0.2 130 7.0 4 9.16 5.6 30.66 na 31.01 0.2 130 7.0 5 9.16 5.6 21.56 na 26.0 0.2 130 7.0 6 9.16 5.6 23.91 na 27.38 0.2 130 7.0 7 9.16 5.6 25.79 na 28.44 0.2 130 7.0 8 9.16 5.6 30.66 na 31.01 0.2 130 7.0 9 9.16 37.58 na 10 9.16 43.1 na Al 19.83 50.2 na A2 19.83 50.19 na A3 19.83 50.19 na A4 19.83 50.17 na A5 19.83 50.15 na A6 19.83 50.17 na A7 19.83 50.19 na A8 19.83 50.2 na A9 19.83 50.2 na II 19.83 50.14 na BI 19.83 51.43 na B2 19.83 51.44 na B3 19.83 51.44 na B4 19.83 51.46 na B5 19.83 51.48 na B6 19.83 51.53 na Cl 19.83 51.58 na B7 19.83 51.58 na B8 19.83 51.57 na TR 19.83 51.72 na BR 1.0 60.01 na UI 1.0 60.01 na SRC 0.0 60.59 na 250.0 The maximum velocity is 18.99 and it occurs in the pipe between nodes 9 and 10 EOD TOTAL FIRE PROTECTION Page 5 FASHIONPHILE MEZZANINE Date 5/9/18 Nodel EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 1 9.160 5.60 26.00 1 0.0 13.000 120 21.556 to 0.0 0.0 0.0 2 9.160 26.0 1.083 0.0 13.000 0.1810 2.353 Vel = 9.06 2 9.160 5.60 27.38 1.25 0.0 10.200 120 23.909 to 0.0 0.0 0.0 3 9.160 53.38 1.418 0.0 10.200 0.1844 1.881 Vel = 10.84 3 9.160 5.60 28.44 1.25 0.0 12.000 120 25.790 to 0.0 0.0 0.0 4 9.160 81.82 1.418 0.0 12.000 0.4062 4.875 Vel = 16.62 4 9.160 5.60 31.01 1.5 E 4.561 6.200 120 30.665 to T 9.123 13.684 0.0 9 9.160 112.83 1.654 0.0 19.884 0.3478 6.916 Vel = 16.85 0.0 9 112.83 37.581 K Factor = 18.41 5 9.160 5.60 26.00 1 0.0 13.000 120 21.556 to 0.0 0.0 0.0 6 9.160 26.0 1.083 0.0 13.000 0.1810 2.353 Vel = 9.06 6 9.160 5.60 27.38 1.25 0.0 10.200 120 23.909 to 0.0 0.0 0.0 7 9.160 53.38 1.418 0.0 10.200 0.1844 1.881 Vel= 10.84 7 9.160 5.60 28.44 1.25 0.0 12.000 120 25.790 to 0.0 0.0 0.0 8 9.160 81.82 1.418 0.0 12.000 0.4062 4.875 Vel = 16.62 8 9.160 5.60 31.01 1.5 E 4.561 6.200 120 30.665 to T 9.123 13.684 0.0 9 9.160 112.83 1.654 0.0 19.884 0.3478 6.916 VeI= 16.85 0.0 9 112.83 37.581 KFactor= 18.41 9 9.160 225.66 2 T 13.639 4.120 120 37.581 to 0.0 13.639 0.0 10 9.160 225.66 2.203 0.0 17.759 0.3105 5.515 Vel = 18.99 10 9.160 0.0 2 E 6.819 17.120 120 43.096 to T 13.639 20.458 -4.621 11 19.830 225.66 2.203 0.0 37.578 0.3105 11.668 Vel = 18.99 0.0 11 225.66 50.143 KFactor= 31.87 Al 19.830 24.28 2 4T 49.227 173.330 120 50.196 to 0.0 49.227 0.0 61 19.830 24.28 2.157 0.0 222.557 0.0056 1.238 Vel = 2.13 0.0 BI 24.28 51.434 KFactor = 3.39 A2 19.830 24.32 2 4T 49.227 173.330 120 50.194 to 0.0 49.227 0.0 B2 19.830 24.32 2.157 0.0 222.557 0.0056 1.242 Vel = 2.14 0.0 B2 24.32 51.436 K Factor = 3.39 A3 19.830 24.47 2 4T 49.227 173.330 120 50.187 to 0.0 49.227 0.0 63 19.830 24.47 2.157 0.0 222.557 0.0056 1.257 Vel = 2.15 Final Calculations - Hazen-Williams TOTAL FIRE PROTECTION Page 6 FASHIONPHILE MEZZANINE Date 5/9/18 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Notes ****** Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 B3 24.47 51.444 K Factor = 3.41 A4 19.830 24.77 2 4T 49.227 173.330 120 50.173 to 0.0 49.227 0.0 64 19.830 24.77 2.157 0.0 222.557 0.0058 1.285 Vel = 2.17 0.0 B4 24.77 51.458 K Factor = 3.45 A5 19.830 25.32 2 4T 49.227 173.330 120 50.146 to 0.0 49.227 0.0 65 19.830 25.32 2.157 0.0 222.557 0.0060 1.338 Vel = 2.22 0.0 B5 25.32 51.484 K Factor = 3.53 A6 19.830 25.49 2 4T 49.227 173.330 120 50.170 to 0.0 49.227 0.0 66 19.830 25.49 2.157 0.0 222.557 0.0061 1.355 VeI= 2.24 0.0 B6 25.49 51.525 K Factor = 3.55 A7 19.830 25.81 2 4T 49.227 173.330 120 50.188 to 0.0 49.227 0.0 B7 19.830 25.81 2.157 0.0 222.557 0.0062 1.387 VeI= 2.27 0.0 67 25.81 51.575 K Factor = 3.59 A8 19.830 25.63 2 4T 49.227 173.330 120 50.197 to 0.0 49.227 0.0 68 19.830 25.63 2.157 0.0 222.557 0.0062 1.369 Vel = 2.25 0.0 68 25.63 51.566 K Factor = 3.57 A9 19.830 25.58 2 4T 49.227 173.330 120 50.200 to 0.0 49.227 8.588 89 0 25.58 2.157 0.0 222.557 0.0061 1.364 Vel = 2.25 0.0 69 25.58 60.152 K Factor = 3.30 Al 19.830 -24.28 4 0.0 10.000 120 50.196 to 0.0 0.0 0.0 A2 19.830 -24.28 4.26 0.0 10.000 -0.0002 -0.002 Vel = 0.55 A2 19.830 -24.31 4 0.0 10.000 120 50.194 to 0.0 0.0 0.0 A3 19.830 -48.59 4.26 0.0 10.000 -0.0007 -0.007 Vel = 1.09 A3 19.830 -24.48 4 0.0 9.000 120 50.187 to 0.0 0.0 0.0 A4 19.830 -73.07 4.26 0.0 9.000 -0.0016 -0.014 Vel = 1.64 A4 19.830 -24.76 4 0.0 10.000 120 50.173 to 0.0 0.0 0.0 A5 19.830 -97.83 4.26 0.0 10.000 -0.0027 -0.027 Vel = 2.20 A5 19.830 -25.32 4 0.0 0.830 120 50.146 to 0.0 0.0 0.0 11 19.830 -123.15 4.26 0.0 0.830 -0.0036 -0.003 Vel = 2.77 Final Calculations - Hazen-Williams TOTAL FIRE PROTECTION Page 7 FASHIONPHILE MEZZANINE Date 5/9/18 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 11 19.830 225.67 4 0.0 9.160 120 50.143 to 0.0 0.0 0.0 A6 19.830 102.52 4.26 0.0 9.160 0.0029 0.027 Vet = 2.31 A6 19.830 -25.50 4 0.0 11.000 120 50.170 to 0.0 0.0 0.0 A7 19.830 77.02 4.26 0.0 11.000 0.0016 0.018 Vel = 1.73 A7 19.830 -25.81 4 0.0 11.080 120 50.188 to 0.0 0.0 0.0 A8 19.830 51.21 4.26 0.0 11.080 0.0008 0.009 Vel = 1.15 A8 19.830 -25.63 4 0.0 11.080 120 50.197 to 0.0 0.0 0.0 A9 19.830 25.58 4.26 0.0 11.080 0.0003 0.003 Vel = 0.58 0.0 A9 25.58 50.200 K Factor = 3.61 BI 19.830 24.28 4 0.0 10.000 120 51.434 to 0.0 0.0 0.0 62 19.830 24.28 4.26 0.0 10.000 0.0002 0.002 Vel = 0.55 B2 19.830 24.31 4 0.0 10.000 120 51.436 to 0.0 0.0 0.0 63 19.830 48.59 4.26 0.0 10.000 0.0008 0.008 Vel = 1.09 63 19.830 24.48 4 0.0 9.000 120 51.444 to 0.0 0.0 0.0 B4 19.830 73.07 4.26 0.0 9.000 0.0016 0.014 Vet = 1.64 B4 19.830 24.76 4 0.0 10.000 120 51.458 to 0.0 0.0 0.0 65 19.830 97.83 4.26 0.0 10.000 0.0026 0.026 Vel = 2.20 65 19.830 25.32 4 0.0 10.000 120 51.484 to 0.0 0.0 0.0 66 19.830 _123.15 4.26 0.0 10.000 0.0041 0.041 Vel = 2.77 66 19.830 25.49 4 0.0 9.200 120 51.525 to 0.0 0.0 0.0 Cl 19.830 148.64 4.26 0.0 9.200 0.0058 0.053 Vel = 3.35 Cl 19.830 -225.66 4 0.0 1.790 120 51.578 to 0.0 0.0 0.0 B7 19.830 -77.02 4.26 0.0 1.790 -0.0017 -0.003 Vel = 1.73 B7 19.830 25.81 4 0.0 11.080 120 51.575 to 0.0 0.0 0.0 B8 19.830 -51.21 4.26 0.0 11.080 -0.0008 -0.009 Vel = 1.15 88 19.830 25.63 4 0.0 11.080 120 51.566 to 0.0 0.0 8.588 69 0 -25.58 4.26 0.0 11.080 -0.0002 -0.002 Vel = 0.58 0.0 B9 -25.58 60.152 K Factor= -3.30 Cl 19.830 225.66 6 T 37.72 26.370 120 51.578 to E 17.603 55.323 0.0 TR 19.830 225.66 6.357 0.0 81.693 0.0018 0.146 Vel = 2.28 TR 19.830 0.0 6 S 40.235 18.830 120 51.724 to B 12.573 52.808 8.155 BR 1 225.66 6.357 0.0 71.638 0.0018 0.128 Vel = 2.28 Final Calculations - Hazen-Williams TOTAL FIRE PROTECTION Page 8 FASHIONPHILE MEZZANINE Date 5/9/18 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf BR 1 0.0 8 0.0 12.000 140 60.007 to 0.0 0.0 0.0 UI 1 225.66 8.27 0.0 12.000 0.0003 0.004 Vel = 1.35 UI 1 0.0 8 G 6.041 300.000 150 60.011 to S 67.957 73.997 0.433 SRC 0 225.66 7.98 0.0 373.997 0.0004 0.146 Vel = 1.45 250.00 Qa = 250.00 SRC 475.66 60.590 K Factor= 61.11 tqcci Fire Protection Products Worldwide Contacts www.tyco-fire.com 9-4 Series TY-B, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers described in this data sheet are standard response, standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TV-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TV-B Sprinklers are described in Technical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The Series TY-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Numbers (SINs) TY315 ......Upright 5.6K, 1/2" NPT Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion- Resistant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K = 5.6 GPM/p5i1/2 (80,6 LPM/barl/2) FEBRUARY 2014 Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C)t t UL, C-UL, and VdS Approved only Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly ... ......Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector ................. Bronze TFPI52 TFPI52 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (11.1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* I 7/16" (1111,11 mm) MAKE-IN (50,8 mm) 2 ______ NOMINAL 2" - 2" 1-3/8" 3 (50,8 mm) A (34,9 mm) WRENCH FLATS t I 1/2" NPT** DEFLECTOR * -.___ 2-7/8" (73,0 mm) DIA.J CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TV-B UPRIGHT (TY315) AND PENDENT (TY325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TV-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY END "A") FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 6 t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI52 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TV-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 15 or Style 20 Closure over the Series TV-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TV-B, 5.6 K-factor, Upright (TV315) and Pendent (TV325) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Thereafter, annual inspections per NFPA 25 are required; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4° DIA. FACE OF (57,2 mm) SPRINKLER _I FLUSH 3/8±5/16° I FITTING 5/8° (15,9 mm) _ (9,5*7,9 mm) 17 . .6 MOUNTING / 1/8° j I SURFACE , ,/ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8° (34,9 mm) TV-B PLATE 3/4° (19,1 mm) FIGURE 4 SERIES TYB RECESSED PENDENT SPRINKLER ASSEMBLY (1Y325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8° DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4' DIA. 5/16±1/4° (7,9±6,4 mm) \ ____________ 1/2° (12,7 mm) FITTING (57,2 mm) FLUSH I/ MOUNTING / . ] SURFACE/I _____ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8° (34,9 mm) TV-B PLATE 7/8° (22,2 mm) FIGURE 5 SERIES TYB RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI52 Page 4 of 4 P/N* 77 - XXX - X - XXX I I F SIN I SPRINKLER I TEMPERATURE FINISH RATINGS 570 I 5.61K UPRIGHT (1/2 NPT) I 1Y315 I I 1 I NATURAL BRASS I 571 5.6K PENDENT (112 NPT) TY325 PURE WHITE (RAL9O1O)°° I POLYESTER Use suffix "I" for ISO 7-1 connection; I SIGNAL WHITE (RAL9003) for example, 77-570-4-175-I I POLYESTER 9 I CHROME PLATED Eastern Hemisphere sales only 135 135°F(57°C) 155 155-F (68-C) 175 175°F(79°C) 200 200°F (93°C) 286 286-F (141-C) 360 360°F (182°C) 000 OPEN OPEN indicates sprinkler assembly without Glass Bulb, Button, and Sealing Assembly TABLE A SERIES TV.B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TV-B Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A) Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1 -215-362-0700 Copyright 0 2014 Tyco Fire Products, LP. All rights reserved. tuco