Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5334 PASEO DEL NORTE; ; AS150058; Permit
2/15/24,1:16 PM - AS150058 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS150058 5334 PASEO DEL Job Address: Status: FINAL NORTE Permit Type: SPRINK Applied 4/1/2015 Parcel No: 2110600200 Approved: 4/7/2015 Lot #: 0 Reference No.: Issued: 4/7/2015 PC #: Inspector: Project Title: HOEHN BUICK CADILLAC Applicant: LINDLEY FIRE PROTECTION CO INC 2220 E. VIA BURTON ANAHEIM, CA 92806 714-535-5761 Owner: HOEHN ENTERPRISE I L L C P0 BOX 789 CARLSBAD CA Fees ($) Add'i Fees ($) Total ($) Balance ($) 280 0 280 0 about:blank 1/1 Co LC) 0 0 LC) Cl) FLEY Automatic Fire Sprinkler System Hydraulic Calculations for Job Name : Hoehn Buick-Cadillac Building : Service Building Location : 5334 Paseo Del Norte Carlsbad, CA System : Wet-Pipe Auto. Sprinkler System Contract : A-2714 Data File : Hoehn Buick-Cadillac - Sery Bldg.wxf These plans have been reviewed for apparent compliance with the current applicable codes and standards in force in the jurisdiction. The owner or contractor may utilize this review in support of an application for a building permit or certificate of occupancy, with the express understanding that this review is not intended to relieve the owner, contractor, architect, or professional engineer for sole responsibility for full compliance with said codes and standards, including the building & fire codes or for any responsibility for deficiencies, errors, omissions or negligence in these plans whether or not-noted in this review. Date: Review by Recommend Approval Recommend Approval As Noted Provided By: LINDLEY FIRE PROTECTION, INC. 2220 E. Via Burton Anaheim, CA 92806 (714) 535-5761 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fire Flow Calculations FOR Hoehn Buick-Cadillac 5334 Paseo Del Norte THE CITY OF CARLSBAD CALIFORNIA Report Dated: March 27, 2014 Prepared For: Owner Hoehn Enterprise I LLC 475 Car Country Drive Carlsbad, CA 92018 Prepared By: Jones, Cahi & Associates 18090 Beach Boulevard, Suite 12 Huntington Beach, CA 92648 (714) 848-0566.'- Fax- (7 l4548-6322 • (ER 1a,L:4/; M Daniel Rubio R C.E. 60934 Scenario No. 1 On-Site Fire Sprinkler Demand of 1,500 gpm Fire Flow Requirements The base fire flow from the 2013 CFC Appendix B for a 14,100 square foot Type V-B construction is 3,250 gpm at a residual pressure of 20 psi for the duration of 3 hours. Since the building is provided with an approved automatic sprinkler system, a reduction in fire flow of up to 75 percent is allowed (2013 CFC Section B105.2 Exception 1). The reduction will result in a required fire flow of 1,500 gpm. A water flow test was performed by Tate Fire Protection Services Inc. and verified by the City of Carlsbad on March 11, 2014 on a hydrant located on the east side of Paseo Del Norte at 5424 Paseo Del Norte and the gauge hydrant, 27B2H6, is located on the west side of Paseo Del Norte (See attached results and hydrant map). A summary of the water test results are as follows: Static Pressure: 81 psi Residual Pressure: 69 psi Pitot Pressure: 50 psi Flow Rate: 1,186 gpm The available water supply at 20 psi was calculated at 2,855 gpm (See attached results). Therefore the fire flow is adequate. Fire Flow Pressure and Flow Calculations Using the Pressure v. Flow diagram form the water flow test provided by Tate Fire (see attached). For a demand of 1,500 gpm a pressure of 62 psi is used at the point of connection. Converting the initial pressure of 62 psi to an available head in feet: 62 psi x (144 sq. in./62.4 p.c.f.) = 143.08 feet (available head) At the end of the fire sprinkler connection to the existing service bay Junction J-3 a pressure of 32.1 psi for a demand of 1,500 gpm. FlexTable: Reservoir Table (1 3-2058.wtg) Lab Eon - Row(o HriGdfl (if) (gpm) (if) 28 ( R-1 143.08 1,500 143.08 FlexTable: Pipe Table (13-2058.wtg) rIo Label Sgr-Dio-de Stop Dmter - (Scaled) Node (in) C Valve? Coefficient (gpm) (fVs) Gradient (if) (Local) (ft/if) 30 P-i 55 R-1 i-i 6.0 Ductile Iron 130.0 True 1.730 1,500 17.02 0.2 32 P-2 120 3-1 J-2 6.0 PVC 150.0 False 0.000 1,500 17.02 0.1 36 P-4 134 3-2 J-4 6.0 PVC 150.0 False 0.000 1,500 17.02 0.1 37 P-5 147 J-4 J-3 6.0 PVC 150.0 False 0.000 1,500 17.02 0.1 39 P-6 25 3-4 3-5 6.0 PVC 150.0 False 0.000 0 0.00 0.0 FlexTable: Junction Table (13-2058.wtg) I ID - Libel - -- Elevatió The dHydàuIic Pressure (if) (gpm) Grade (psi) (if) 29 3-1 0.00 0 126.62 54.8 313-2 0.00 0 112.15 48.5 333-3 4.00 1,500 78.21 32.1 353-4 0.00 0 96.00 41.5 38 3-5 0.00 0 96.00 41.5 4 Scenario: Base Bentley Systems, Inc. Haestad Methods Solution Bentley WaterCAD V8i (SELECTseries 2) 13-2058.wtg Center [08.11.02.31] 8/14/2014 27 Siemon Company Drive Suite 200W Page 1 of I Watertown, CT 06795 USA +1-203-755-1666 - --- --- - - - Carlsbad Municipal Water District Potable Water Discharge Event Report Date: ,z - At b Location: 1 F AS ED beL 2tfL Reason for Discharge Event: ..i_E1C-c _ Type of Event Initial Dewatering Water Mains _N_L!k Estimated Discharge Flow: GPM Note: Includes flow testing and flushing Dewatering Water Mains _JJ±..... Start Time Unscheduled Water Discharge N (Ar Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. 14 Fib Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharged water. End Time Pre-Dechiorination Residual: Post-Dechlorination Residual: 2J (Less than 0.1 mg/L) PH within limits of 6.0 and 9.0 jc Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. N/A Upon completion of dewatering, ensure that any sediments or silted areas are cleared. YE Water Sampling Performed by: Comments: Submitted by: Reviewed by: (Name & Date) (Name & Date) - -: of - J72I45 - PLJ i ;_••%_• - ' 1 2M1H5 \ 8218 I • - (. I. ' • .0 \ i - 2891'. ft 3 ?B4HI&L.J ----- : ' \ 4% • - \ % - • N I _-'-'• \ - 28A3HA \ \ 2m4Ha' • • - . a - . rt' - •- / ____ ' ALL 44 \ :' • tI(1 - 28 \\_ ' • . 1: tqC01Fire & Building Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-B - 28, 56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TV-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10(1/2 inch NPT) or Style 40(3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TV-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII5I - Upright 2.8K, 1I2"NPT TY1251 - Pendent 2.8K, 1/2"NPT TY3151 - Upright 5.6K, 112"NPT TY3251 - Pendent 5.6K, 1/2"NPT TY4151 - Upright 8.0K, 314"NPT TY4251 - Pendent 8.0K, 3/4"NPT TY4851 - Upright 8.0K, 112"NPT TY4951 - Pendent 8.0K, 1/2"NPT Page 1 of 8 DECEMBER, 2007 TFPI5I I •- 4 CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. S Page 20f8 TFPI5I ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9/16" WRENCH (39,7 mm) FLATS w..__ SSP DEFLECTOR PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression 7 - Bushing Screw 7/16"(11,1 mm) 1/2" ** NOMINAL MAKE-IN NPT SSU * DEFLECTOR FIGURE 1 STANDARD RESPONSE SERIES TV-B UPRIGHT (TYI 151) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2_3/16,' 6mm) (55,6 mm)1- (38, SSU* DEFLECTOR 7/16" 11,1 mm) "IOMINAL MAKE-IN I 2-3/16" (55,6 mm) 1/2" ** NPT 7/16(11,1 mm) STYLE 10 NOMINAL RECESSED MAKE-IN ESCUTCHEON SSP DEFLECTOR* H— 2-7/8" (73,0 mm) DIA. -H 1/2" NPT** 6* 5 4 2 3 I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT s-,- DEFLECTOR PENDENT UPRIGHT CROSS SECTION - ESCUTCHEON PLATE SEATING SURFACE T_ 2-1/4" (57,2 mm) f 1-9/16" (39,7 mm) 7/16(11,1 mm) 1/2" ** NOMINAL MAKE-IN NPT SSU * DEFLECTOR WRENCH FLATS TFPI5I Page 3 of 8 ESCUTCHEON 1/2" (12,7 mm) STYLE 40 PLATE SEATING ,, ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON SSU* NPT DEFLECTOR zi 6* _____ ____ 1/2" 2-5/16" ______ (12,7 mm) NOMINAL I 4 (58,7 mm) $ (57,2 mm) MAKE-IN 1-9/16" (39,7 mm) WRENCH _________ I 2-1/4 2 b- FLATS _____________________ SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA. --1 3/4" NPT** PENDENT RECESSED PENDENT UPRIGHT , CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TV-B UPRIGHT (TV4851) AND PENDENT (TV4951) SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Page 4 of 8 TFPISI SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE IPOLYESTER LEAD COATED I WAX COATED WAX OVER tLEAD COATED 2.8 1/2' NPT PENDENT (TY1251) and UPRIGHT (TYII5I) 135°F/57°C Orange 1,2,3 N/A 155°F/68C Red 175°F/790C Yellow 200°F/930C Green 286°F/141°C Blue 360'F/182°C Mauve 1,2 5.6 1/2" NPT PENDENT (TY3251) and UPRIGHT (TY3151) 135FI57C Orange 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 155°F/68C Red 175F/79C Yellow 200°F/93°C Green 286F/141°C Blue 1,2**, 3** 5_ 1, 2', 3**, 5- 360°F/182C Mauve N/A 135°F/57C Orange 1, 2, 3,4, 5 N/A RECESSED PENDENT (TY3251)* Figure 4 155°F/68C Red 175F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 1,2 8.0 NPT PENDENT (TY4251) and UPRIGHT (TY4151) 135'F/57°C Orange 1,2,3,4, 5,6, 7 1,2,5 1,2, 3, 5 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93'C Green 286F/141°C Blue 1,2**, 3** 5 1, 2, 5** 360°F/182°C Mauve N/A 135°F/57°C Orange 1, 2, 3, 4,5 N/A RECESSED PENDENT (TY4251) Figure 5 1550F/68C Red 175F/79'C Yellow 200°F/93°C Green 286°F/141°C Blue 1,2 8.0 1/2" NPT PENDENT (TY4951) and UPRIGHT (TY4851) 135°F/57°C Orange 1,2,3,4, 5,6 N/A 155'F/68°C Red 175°FR9°C Yellow 200°F/93°C Green 286°F/141C Blue 360°F/182°C Mauve NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k103). Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 150°F/66*C Maximum Ceiling Temperature. Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A, LABORATORY LISTINGS AND APPROVALS TFPI5I K 2.8 1/2" NPT 5.6 1/2" NPT 8.0 3/4" NPT 8.0 1/2' NPT NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 2.8 GPM/p5i112 (40,3 LPM/barl'2) K = 5.6 GPMIpsi"2 (80,6 LPM/bar"2) K = 8.0 GPM/psi112 (115,2 LPM/bar112) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector ...........Copper Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TV-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. 2-7/8" DIA. (73,0 mm) I 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2mm) MOUNTING F,I A•r I LJ I (3,2 mm) 1-5/16" (33,3 mm) 13/16" (20,6 mm) 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TV-B Page 6 of 8 TFPI5I -- 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF 2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) i- / I MOUNTING SURFACE/ f CLOSURE SERIES 1-1/4" (31,8 mm) TV-B 3/4" (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The Series TV-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135UF/570C to 3/32 inch (2,4 mm) for the 360°F/1820C temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A 3/4 inch NPT sprinkler joint should be obtained with a mini- mum to maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the TFPI5I Page 7 of 8 sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TV-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coaling ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. The Series TV-B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 0r4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TV-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TV-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in ac- cordance with local requirements and/or national codes. Page 8 of 8 TFPI5I PIN 57-XXX-X-XXX I SPRINKLER I TEMPERATURE MODEL/SIN RATING 530 2.8K UPRIGHT (1/2"NPT) TY1I51 1 NATURAL BRASS 135 135°F/57°C 531 2.8K PENDENT (1/2"NPT) TY1251 4 WHITE POLYESTER 155 155F/68°C 570 5.6K UPRIGHT (1/2"NPT) TY3151 3 WHITE (RAL9010) * 175 175°F179°C 571 5.6K PENDENT (1/2"NPT) TY3251 9 CHROME PLATED 200 200*F/93*C 590 8.0K UPRIGHT (3/4"NPT) TY4151 7 LEAD COATED 286 286*F/141*C 591 8.0K PENDENT (314"NPT) TY4251 6 WAX COATED ' 360 3600F/182*C - 286°F/141°C MAX. 560 8.0K UPRIGHT (1/2"NPT) TY4851 - 8 WAX OVER LEAD 561 8.0K PENDENT (1/2"NPT) TY4951 286°F/141°C MAX. / Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TV-B PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TV-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify 10 or 40) Re- cessed Escutcheon with (specify*) fin-ish, P/N (specify*). Refer to Technical Data Sheet TFP770 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Lindley Fire Protection Page Hoehn Buick Cadillac - Service Building Date FEB 2015 Hydraulic Design Information Sheet Name - Hoehn Buick Cadillac - Service Building Date - FEB 2015 Location - Carlsbad, CA Building - Service Bldg. System No. - 1 of 1 Contractor - WL Butler Construction Contract No. - A-2714 Calculated By - Ed Delgado Drawing No. - FP-1.0 Construction: (X) Combustible C ) Non-Combustible Ceiling Height - 151 -0" Occupancy - Ordinary Hazard 2 (X) NFPA 13 Lt. Haz. Ord.Haz.Gp. C ) 1 (X) 2 C ) 3 C ) Ex.Haz. NFPA 231 NFPA 231C ( ) Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - 1,500 SF System Type Sprinkler/Nozzle Density - .20 gpm (X) Wet Make Tyco Area Per Sprinkler - 95 SF C ) Dry Model TY-B Elevation at Highest Outlet - 131 -6" C ) Deluge Size 1/2" Hose Allowance - Inside - 0 C ) Preaction K-Factor 5.6 Rack Sprinkler Allowance - 0 C ) Other Temp.Rat.200°F Hose Allowance - Outside - 250 gpm Note Calculation Flow Required - 437.24 Press Required - 64.61 At Node BR Summary C-Factor Used: 120 Overhead 150 Underground S Y S T E M D E S I G N Water Flow Test: Date of Test - 3/11/2014 Time of Test - Static Press - 81 psi Residual Press - 69 psi Flow - 1,186 gpm Elevation - 0 Pump Data: Tank or Reservoir: Cap. - N/A Rated Cap.- N/A Elev.- 8 Press - Elev. - Well Proof Flow N/A W A T E R S U P P L Y Location - Between 5335 & 5445 Paseo Del Norte Source of Information - Carlsbad Municipal Water Dist. C Commodity N/A Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled N/A % Palletized N/A % Rack N/A M Single Row ( ) Conven. Pallet C ) Auto. Storage C ) Encap. S R C ) Double Row ( ) Slave Pallet C ) Solid Shelf C ) Non T A C ) Mult. Row C ) Open Shelf 0 R K Flue Spacing N/A Clearance:Storage to Ceiling A Longitudinal N/A Transverse N/A G E Horizontal Barriers Provided: N/A Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) Lindley Fire Protection Page 2 t Hoehn Buick Cadillac - Service Building Date FEB 2015 City Water Supply: Demand: Cl - Static Pressure : 81 Dl - Elevation : 5.847 C2 - Residual Pressure: 69 D2 - System Flow : 437.238 C2 - Residual Flow : 1186 D2 - System Pressure : 69.734 Hose ( Demand) : 250 D3 - System Demand : 687.238 Safety Margin : 6.893 150 - _____ _______ __________ ___________ _____________ _______________ _________________ ___________________ 140 130 p120 R° E10° 90 CI 80 D2 ______ ________ C2 U 70 - - -- R 60 E 50 - D3 - rent Under 40 30 20 10 U .iiIS ...I I I I I . . 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N'11.85) Fittings Used Summary Lindley Fire Protection Page 3 Hoehn Buick Cadillac - Service Building Date FEB 2015 Filling Legend Abbrev. Name 1/2 % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcd Colt C300 Horz Bull Filling generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Pressure / Flow Summary - STANDARD Lindley Fire Protection Page 4 Hoehn Buick Cadillac - Service Building Date FEB 2015 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 01 13.5 5.6 11.51 na 19.0 0.2 95 11.4 02 13.5 5.6 11.59 na 19.07 0.2 95 11.4 03 13.5 5.6 11.9 na 19.31 0.2 95 11.4 04 13.5 5.6 12.54 na 19.83 0.2 95 11.4 05 13.5 5.6 13.65 na 20.69 0.2 95 11.4 06 13.5 5.6 21.27 na 25.83 0.2 95 11.4 07 13.5 5.6 23.94 na 27.4 0.2 95 11.4 08 13.5 35.26 na 09 13.5 5.6 14.59 na 21.39 0.2 95 11.4 10 13.5 5.6 14.7 na 21.47 0.2 95 11.4 11 13.5 5.6 15.07 na 21.74 0.2 95 11.4 12 13.5 5.6 15.87 na 22.31 0.2 95 11.4 13 13.5 5.6 17.26 na 23.27 0.2 95 11.4 14 13.5 5.6 19.41 na 24.67 0.2 95 11.4 15 13.5 5.6 22.54 na 26.59 0.2 95 11.4 16 13.5 35.33 na 17 13.5 5.6 30.07 na 30.71 0.2 95 11.4 18 13.5 5.6 30.27 na 30.81 0.2 95 11.4 19 13.5 5.6 31.01 na 31.18 0.2 95 11.4 20 13.5 5.6 32.57 na 31.96 0.2 95 11.4 21 13.5 37.02 na 22 13.5 43.27 na 23 13.5 50.79 na TR 13.5 58.37 na BR 0.0 64.61 na UG1 0.0 66.64 na UG2 0.0 69.27 na SRC 0.0 69.73 na 250.0 The maximum velocity is 22.09 and it occurs in the pipe between nodes 15 and 16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Lindley Fire Protection Page 5 Hoehn Buick Cadillac - Service Building Date FEB 2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'IC" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn * BRANCH-LINE #1 01 19.00 1.728 0.0 8.000 11.512 K Factor =5.60 to 120.0 0.0 0.0 0.0 02 19.0 0.0104 0.0 8.000 0.083 Vel = 2.60 02 19.07 1.728 0.0 8.000 11.595 K Factor= 5.60 to 120.0 0.0 0.0 0.0 03 38.07 0.0376 0.0 8.000 0.301 Vel = 5.21 03 19.31 1.728 0.0 8.000 11.896 K Factor= 5.60 to 120.0 0.0 0.0 0.0 04 57.38 0.0805 0.0 8.000 0.644 Vel = 7.85 04 19.83 1.728 0.0 8.000 12.540 K Factor = 5.60 to 120.0 0.0 0.0 0.0 05 77.21 0.1393 0.0 8.000 1.114 Vel = 10.56 05 20.70 1.728 4E 22.58 12.668 13.654 K Factor 5.60 to 120.0 0.0 22.580 0.0 06 97.91 0.2162 0.0 35.248 7.620 Vel = 13.39 06 25.83 1.728 0.0 8.000 21.274 K Factor = 5.60 to 120.0 0.0 0.0 0.0 07 123.74 0.3334 0.0 8.000 2.667 Vel = 16.93 07 27.40 1.728 iT 11.29 12.167 23.941 K Factor = 5.60 to 120.0 0.0 11.290 0.0 08 151.14 0.4827 0.0 23.457 11.322 Vel = 20.68 0.0 151.14 35.263 KFactor= 25.45 * CROSS-MAIN 08 151.14 4.31 0.0 11.833 35.263 to 120.0 0.0 0.0 0.0 16 151.14 0.0057 0.0 11.833 0.067 . Vel = 3.32 0.0 151.14 35.330 KFactor= 25.43 * BRANCH-LINE #2 09 21.39 1.728 0.0 8.000 14.593 K Factor= 5.60 to 120.0 0.0 0.0 0.0 10 21.39 0.0130 0.0 8.000 0.104 VeI= 2.93 10 21.47 1.728 0.0 8.000 14.697 K Factor =5.60 to 120.0 0.0 0.0 0.0 ii 42.86 0.0469 0.0 8.000 0.375 Vel = 5.86 ii 21.74 1.728 0.0 8.000 15.072 K Factor =5.60 to 120.0 0.0 0.0 0.0 12 64.6 0.1001 0.0 8.000 0.801 Vel = 8.84 12 22.31 1.728 0.0 8.000 15.873 K Factor= 5.60 to 120.0 0.0 0.0 0.0 13 86.91 0.1734 0.0 8.000 1.387 Vel = 11.89 13 23.27 1.728 0.0 8.000 17.260 K Factor =5.60 to 120.0 0.0 0.0 0.0 14 110.18 0.2690 0.0 8.000 2.152 Vel = 15.07 14 24.67 1.728 0.0 8.000 19.412 K Factor = 5.60 to 120.0 0.0 0.0 0.0 15 134.85 0.3909 0.0 8.000 3.127 Vel= 18.45 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Lindley Fire Protection Page 6 Hoehn Buick Cadillac - Service Building Date FEB2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 11C11 or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 15 26.59 1.728 IT 11.29 12.167 22.539 KFactor= 5.60 to 120.0 0.0 11.290 0.0 16 161.44 0.5453 0.0 23.457 12.791 Vel = 22.09 0.0 161.44 35.330 KFactor= 27.16 * CROSS-MAIN 16 312.57 4.31 3E 41.811 8.583 35.330 to 120.0 IT 27.874 69.685 0.0 21 312.57 0.0216 0.0 78.268 1.690 Vel= 6.87 0.0 312.57 37.020 KFactor= 51.37 * BRANCH-LINE #3 17 30.71 1.728 0.0 8.000 30.072 K Factor = 5.60 to 120.0 0.0 0.0 0.0 18 30.71 0.0253 0.0 8.000 0.202 Vel = 4.20 18 30.81 1.728 0.0 8.000 30.274 K Factor = 5.60 to 120.0 0.0 0.0 0.0 19 61.52 0.0915 0.0 8.000 0.732 Vel = 8.42 19 31.18 1.728 0.0 8.000 31.006 K Factor= 5.60 to 120.0 0.0 0.0 0.0 20 92.7 0.1955 0.0 8.000 1.564 Vel = 12.68 20 31.96 1.728 0.0 13.167 32.570 K Factor= 5.60 to 120.0 0.0 0.0 0.0 21 124.66 0.3380 0.0 13.167 4.450 Vel = 17.05 0.0 124.66 37.020 K Factor= 20.49 * CROSS-MAIN 21 437.24 4.31 4E 55.748 72.000 37.020 to 120.0 IT 27.874 83.622 0.0 22 437.24 0.0402 0.0 155.622 6.254 Vel = 9.62 22 0.0 4.31 1 13.937 173.000 43.274 to 120.0 0.0 13.937 0.0 23 437.24 0.0402 0.0 186.937 7.512 Vel = 9.62 23 0.0 4.31 3E 41.811 147.000 50.786 to 120.0 0.0 41.811 0.0 TR 437.24 0.0402 0.0 188.811 7.588 VeI= 9.62 0.0 437.24 58.374 K Factor= 57.23 * RISER TR 437.24 6.357 2E 35.205 18.000 58.374 to 120.0 IL 11.316 46.521 5.847 BR 437.24 0.0061 0.0 64.521 0.391 Vel = 4.42 0.0 437.24 64.612 K Factor= 54.40 * UNDERGROUND BR 437.24 6.134 1L 14.37 412.000 64.612 to 150.0 0.0 14.370 0.0 UG1 437.24 0.0048 0.0 426.370 2.033 Vel = 4.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Lindley Fire Protection Page 7 Hoehn Buick Cadillac - Service Building Date FEB 2015 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UGI 0.0 6.134 2Zcd 0.0 4.000 66.645 to 150.0 0.0 0.0 2.604 * Fixed loss = 2.604 UG2 437.24 0.0048 0.0 4.000 0.019 Vel = 4.75 UG2 0.0 6.134 IG 4.79 45.000 69.268 to 150.0 iT 47.899 52.690 0.0 SRC 437.24 0.0048 0.0 97.690 0.466 Vel = 4.75 250.00 Qa = 250.00 687.24 69.734 K Factor= 82.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087