Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5334 PASEO DEL NORTE; ; FA140172; Permit
2/15/24, 2:54 PM FA140172 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA140172 5334 PASEO DEL Job Address: NORTE Permit Type: FALARM Parcel No: 2110600200 Lot #: 0 Reference No.: Status: FINAL Applied 12/16/2014 Approved: 1/8/2015 Issued: 1/8/2015 PC #: Inspector: Project Title: HOEHN BUICK CADILLAC INSTALLATION OF NEW FIRE SPRINKLER AND DUCT DETECTION SYSTEM. Applicant: Owner: KOR FIRE & SECURITY HOEHN ENTERPRISE I L L C 26812 VISTA TERRACE LAKE FOREST, CA 92630 P0 BOX 789 CARLSBAD CA 949-273-8340 Fees ($) Add'I Fees ($) Total ($) Balance ($) 370 497.5 867.5 0 about:blank 1/1 FIRE SUBMITTAL BOOK LE COPY FOR Hoehn Buick Cadillac 5334 Paseo Del Norte Carlsbad, CA 92008 "Our Knowledge Is Your Security" 26812 Vista Terrace Lake Forest, Ca. 92630 California State License: 857.710 FA140172 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0210 Page 1 of I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Model MS-9050U0 addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise),automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 07-07-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division MIN Battery MODEL pS1250F2 I2yee _11 FT7miis () F2 - Quick disconnect tabs, 0.250" x 0.032" - Mate with AMP. INC FASTON "250" series 1-3.4-I =~K &35 H7.95-1 I II 11 =0.8 I T 1 , E. -- n 11 T . gL _ Seee.e. Ir HT H 12 COOCI. PS.r290 F2 aa• I L L: 5.95(151) W:2.56 (65) H: 3.70 (94) HT: 3.86(98) Tolerances are +1- 0.04 in. (+/- 1mm) and /- 0.08 in. (/- 2mm) for height dimensions. All data subject to change without notice. POUJEW a I1 WeIeGotThePowerI PS -129 0 Rechrgeable Sealed Lead Acid Batte y -T • Absorbent Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.0.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 Nominal Voltage........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (450 mA to 10.50 volts) .......................................................9.00 AH 10-hr. (810mA to 10.50 volts) .........................................................8.10 AH 5-hr. (1.44A to 10.20 volts) ...........................................................7.20 AH 1-hr. (5.4A to 9.00 volts) ..............................................................5.40 AH 15-mm. (14.4A to 9.00 volts)..............................................................3.60 AH Approximate Weight ...........................................................6.00 lbs. (2.72 kg) Energy Density (20-hr. rate) ..............................1.92 W-h/1n3 (116.94 W-h/1) Specific Energy (20-hr. rate) .............................18.00 W-h/Ib (39.68 W-h/kg) Internal Resistance (approx.) ......................................................13 milliohms Max Discharge Current (7 Mm.) ................................................27.0 amperes Max Short-Duration Discharge Current (10 Sec.)..................90.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)) 1 Month ......................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Range Charge .. ........................................................... -4°F(-20°C)to 122-F (50-C) Discharge ....................................................... -40°F(-40°C)to 1400F(600C) Case......................................................................................................ABS Plastic Power-Sonic Chargers ................................................ PSC-12800A, 12800A-C •e IwYpppfsonicTcom II CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models 5D350, SD350T, S13355, SD355R*, 3D355T and AD355 photoelectric type smoke detectors. Model SD350T and SD355T has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models 5D355 and S0355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010 fm .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed NO the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52013:C • E-100 BG-12LX Addressable Manual Pull Station (8 FlreureALarms by Honeywell The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACP5). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED' appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13)); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BGI2TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 pA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within DF-52013:C • 0910212009— Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2@Honeywell.com DESIGN: Model ANN-80 and *ANN80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (). Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 -2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. * 6,000 ft. *6000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1172ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and ANN-SO: Red 80 character LCD Annunciator. ANN-BUS devices. ANN-80-1011: White, 80 character LCD Annunciator. = TBI ANN-BUS Device ANN-BUS and power wiring are supervised and power-limited. ANN-SB8OKlT-R: Red surface mount backbox with angled wedge. ANN-SBBOKIT-W: White surface mount backbox with angled wedge. 10, MS-9050UD 12345678 FACP Wiring to ANN-BUS Device FlreLlte® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 9331=1=1 We cannot cover all specific applications or anticipate all requirements. MEINIMINE S MNIFIII1URINN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-52417:c • 05/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL :R) FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-I2LW, BG-I2WP, BG-12LWP, BG-12L, BG-I2LX, BG-12LA, BG-I2PS, BG-I2LSP, BG-12SP, BG-I2LR, BG-I2LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-I2LOB, BG-I2LPS, BG-12LPSP, BG-I2SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to Iistee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with Iistee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-12LW and BG-I2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to Iistee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN Program Coordinator Fire Engineering Division the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S711 MEA: 67-02-E CSFM: 7150-0075:184 FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Flre.Llte is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 91IM1=1=1 We cannot cover all specific applications or anticipate all requirements. MIIfflINE &MANIMCI1RING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire'Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:C • 09/02/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page I of I CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models MDF-300, MMF-301 MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed Sj\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 1\5TE1 EN5 Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlert' Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75,95, 110,115, 135, 150,177, and 185 Horn rated at 88+ ciBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGIALff1G APPROVED 5431 (chimes, horn strobes horns) 3023572 55512 (strobes) MEA approved 7I2S.I6S3I86 3ndeorstrnbes) 7125-I603186 thorn strobes. ME0452.05-E chime strobes) 7135-16S3:1 99 thorns chimes) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Hom/Strobes or chime/strobes* can generate the distinctive three- pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed t the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SpectrAlert Advance Dimensions Wall-mount horn strobes Ceiling-mount horn strobes Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn Strobes Ceiling Strobes pR.f 2-Wire Horn Strobe, Standard cd*, Red SCR Strobe, Standard cd, Red P2RH 2-Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red P2W 2-Wire Horn Strobe, Standard cd, White SCW' Strobe, Standard cd, White P2WH* 2-Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R* 4-Wire Horn Strobe, Standard cd, Red Horns P4RH 4-Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4-Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SRt Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red SRHt Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall White SW Strobe, Standard cd, White BBSC-2 Back Box Skirt, Ceiling, Red SWH* Strobe, High cd, White BBSCW-2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR-HS Trim Ring, Wall, Red PC2R 2-Wire Horn Strobe, Standard cd, Red TRW-HS Trim Ring, Wall White PC2RH 2-Wire Horn Strobe, High cd, Red TRC-HS Trim Ring, Ceiling, Red PC2W*t 2-Wire Horn Strobe, Standard cd, White TRCW-HS Trim Ring, Ceiling, White PC2WH 2-Wire Horn Strobe, High cd, White PC411 4-Wire Horn Strobe. Standard cd, Red PC4RH 4-Wire Horn Strobe, High Cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Notes: Add -Pto model number for plain housing (no'FlREmarking on cover). e.g. P2R-P. t Add -5P to model number for'FUEGV marking on cover, e.g. P2R-SP Standard cd'refërs to strobes that include 15,15/75,30,75,95, 110. and 115 candela settings. High cd'refers to strobes that include 135, 150, 177. and 185 candela settings. c}'5TEN7 3825 Ohio Avenue. St. Charles, IL 60174 2009SYSSflOf• 5j%J5Qe Phone: 800-SENSOR2 . Fax: 630-377-6495 AOS-0395.007 .4/09. /2132 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1487:0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: GENESIS CABLE SYSTEM7701 95TH Street, Pleasant Prairie, Wi 53158 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Email: orville@genesiscable.com DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LOPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type "FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not WA an endorsement or recommendation of the item listed. This listing should not be used to verify correct i v t operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires . June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division