Loading...
HomeMy WebLinkAbout5425 PASEO DEL NORTE; ; AS150259; Permit2/15/24, 4:23 PM AS150259 Permit Data City of Carlsbad Sprinkler Permit 5425 PASEO DEL Job Address: NORTE Permit Type: SPRINK Parcel No: 2110600900 Lot #: 0 Reference No.: Permit No: AS150259 Status: ISSUED Applied 9/7/2015 Approved: 9/7/2015 Issued: 9/7/2015 PC #: Inspector: Project Title: HOEHN AUDI PROVIDE TWO (2) WET PIPE AUTOMATIC FIRE SPRINKLER SYSTEMS FOR NEW COMMERCIAL AUTOMOBILE DEALERSHIP. WET SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED PER NFPA 13, 2013 ED. AND CARLSBAD FIRE DEPARTMENT STANDARDS. TOTAL COMBINED HOSE ALLOWANCE SHALL BE 100 GPM FOR LIGHT HAZARD AREAS; 250 GPM FOR ORDINARY HAZARD AREAS; 500 GPM FOR EXTRA HAZARD AREAS AND 750 GPM FOR THE TIRE STORAGE AREA. PIPING SHALL BE SIZED BASED ON HYDRAULIC CALCULATIONS. Applicant: MILLENNIUM FIRE PROTECTION SUITE F 101 COPPERWOODWY OCEANSIDE, CA 760-722-2722 Owner: HOEHN ENTERPRISE 2 L L C P 0 BOX 789 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) about:blank 1/2 2/15/24, 4:23 PM AS150259 Permit Data 2,144 0 2,144 0 about:blank 2/2 MILLENNIUM FIRE PROTECTION 101 COPPERWOOD WAY STE H OCEANSIDE, CA 92058 760-722-2722 Job Name : HOEHN AUDI CARLSBAD / 't-çPASew &te.t PO r -€- / Building : FP-5 Location : SYSTEM 2 WORK SHOP System : AREA 7 Contract : 15-026 Data File : AREA 7.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION Page 1 HOEHN AUDI CARLSBAD Date 12-18-15 HYDRAULIC CALCULATIONS for Project name: HOEHN AUDI CARLSBAD Location: SYSTEM 2 WORK SHOP Drawing no: FP-5- Date: 12-18-15 Design Remote area number: AREA 7 Remote area location: WORK SHOP Occupancy classification: ORDINARY HAZARD 2 Density: .20 - Gpm/SqFt Area of application: 1,537 - SqFt Coverage per sprinkler: 130 MAX - Sq Ft Type of sprinklers calculated: 5.6 QR SSU No. of sprinklers calculated: 17 In-rack demand: N/A - GPM Hose streams: 250-GPM Total water required (including hose streams): 613.7-GPM @ 52.2 - Psi Type of system: WET Volume of dry or preaction system: N/A - Gal Water supply information Date: 07-1.6-15 Location: SEE PLAN Source: CARLSBAD WATER DISTRICT Name of contractor: MILLENNIUM FIRE Address: 101 COPPERWOOD WAY / I OCEANSIDE, CA. 92058 Phone number: 760-722-2722 Name of designer: JVK Authority having jurisdiction: CARLSBAD FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) ct; t.f1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C MILLENNIUM FIRE PROTECTION Page 2 HOEHN AUDI CARLSBAD Date 12-18-15 City Water Supply: Demand: Cl - Static Pressure : 73.8 Dl - Elevation : 8.554 C2 - Residual Pressure: 30.5 D2 - System Flow : 363.747 C2 - Residual Flow : 3000 D2 - System Pressure : 52.231 Hose (Demand) : 250 D3 - System Demand : 613.747 Safety Margin : 19.270 150 140 130 p120 - — R° E10° s 90 S80 CT U 70 E 50 r: D ::::: 3 :: 40 30 20 10 ... 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (N'1.85) C2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MILLENNIUM FIRE PROTECTION Page 3 HOEHN AUDI CARLSBAD Date 12-18-15 Fitting Legend Abbrev. Name % % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 .45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0. 1 1 1 1 2 2 3 4 5 6 7 8 1,10 11 13 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zic Wilkins 350A0A Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with 'a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. .w,_•._- Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 MILLENNIUM FIRE PROTECTION . Page 4 HOEHN AUDI CARLSBAD Date 12-18-15 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SRC2 73.8 30.5 3000.0 71.501 613.75 52.231 - NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes C20 19.75 5.6 11.49 18.98 C21 19.75 5.6 11.49 18.98 C22 19.75 5.6 10.47 18.12 C23 19.75 5.6 10.47 18.12 C24 19.75 5.6 10.33 18.0 C25 19.75 5.6 10.33 18.0 C26 19.75 5.6 10.46 18.11 C27 19.75 5.6 10.46 18.11 C28 19.75 5.6 11.47 18.96 C29 19.75 5.6 11.47 18.96 C30 19.75 5.6 19.15 24.51 C31 19.75 5.6 18.91 24.35 C32 19.75 5.6 18.91 24.35 C33 19.75 5.6 19.23 24.56 C34 19.75 5.6 20.31 25.23 C35 19.75 5.6 25.13 28.07 C36 19.75 5.6 25.58 28.32 TC20 19.75 12.39 TC21 19.75 11.29 TC22 19.75 11.15 TC23 19.75 11.28 TC24 19.75 12.36 MWO 19.0 37.51 FB24 19.0 37.55 M5 19.0 37.56 MW1 19.0 36.13 TCI 19.0 36.55 TC2 19.0 36.68 TC3 19.0 36.81 TC4 19.0 36.94 TC5 19.0 37.07 MW2 19.0 34.38 TC6 19.0 35.28 TC7 19.0 35.56 TC8 19.0 35.84 TC9 19.0 36.11 TC10 19.0 36.39 MW3 19.0 31.54 TC11 19.0 34.26 TC12 19.0 34.78 TC13 19.0 35.29 MW4 19.0 26.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 MILLENNIUM FIRE PROTECTION Page 5 HOEHN AUDI CARLSBAD Date 12-18-15 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes TC35 19.0 26.83 TC36 19.0 27.31 MW5 19.0 21.8 TC30 19.0 20.55 TC31 19.0 20.29 TC32 19.0 20.29 TC33 19.0 20.63 TC34 19.0 21.76 MW6 19.0 19.47 TC40 19.0 15.12 - TC41 19.0 13.82 TC42 19.0 13.65 TC43 19.0 13.82 TC44 19.0 15.09 MEO 17.0 38.54 MEl 17.0. . 38.54. - ME2 17.0 38.56 ME3 . 17.0 38.6 -- ME4 - - 17.0 38.65 ME5 17.0 38.76 ME6 17.0 38.96 TR2 15.5 40.18 BR2 0.5 46.92 UG3 0.0 47.29 BF3 -3.0 49.75 BF4 -3.0 53.3 UG4 -3.0 53.39 SRC2 0.0 52.23 250.0 n Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 WC MILLENNIUM FIRE PROTECTION Page 6 HOEHN AUDI CARLSBAD Date 12-18-15 Nodel EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf *REMOTE HEAD TO SUPPLY C20 19.750 5.60 18.98 1, T 5.762 3.000 120 11.489 to 0.0 5.762 0.0 TC20 19.750 18.98 1.08 0.0 8.762 0.1025 0.898 Vel = 6.65 0.0 TC20 . 18.98 12.387 KFactor= 5.39 C21 19.750 5.60 18.98 1 T 5.762 3.000 120 11.489 to 0.0 5.762 0.0 TC20 19.750 -18.98 1.08 0.0 8.762 0.1025 0.898 VeI= 6.65 0.0 TC20 18.98 12.387 K Factor= 5.39 C22 19.750 5.60 18.12 1 T 5.762 3.000 120 10.466 to 0.0 5.762 0.0 TC21 19.750 18.12 1.08 0.0 8.762 0.0940 0.824 Vel= 6.35 0.0 TC21 18.12 11.290 KFactor= 5.39 C23 19.750 5.60 18.12 1 T 5.762 3.000 120 10.466 to . 0.0 5.762 0.0 TC21 19.750 18.12 1.08 0.0 8.762 0.0940 0.824 Vel = 6.35 0.0 TC21 18.12 11.290 K Factor = 5.39 C24 19.756 5.60 18.00 1 T 5.762 3.000 120 10.332 to 0.0 5.762 0.0 TC22 19.750 18.0 1.08 0.0 8.762 0.0929 0.814 Vel = 6.30 0.0 TC22 18.00 11.146 K Factor= 5.39 C25 19.750 5.60 18.00 1 T 5.762 3.000 120 10.332 to 0.0 5.762 0.0 1C22 19.750 18.0 1.08 0.0 8.762 0.0929 0.814 Vel = 6.30 0.0 TC22 18.00 11.146 K Factor = 5.39 C26 19.750 5.60 18.11 1 T 5.762 3.000 120 10.461 to . 0.0 5.762 0.0 TC23 19.750 18.11 1.08 0.0 8.762 0.0939 0.823 Vel = 6.34 0.0 1C23 18.11 11.284 K Factor = 5.39 C27 19.750 5.60 18.11 1 T 5.762 3.000 120 10.461 to 0.0 5.762 0.0 TC23 19.750 18.11 1.08 0.0 8.762 0.0939 0.823 Vel= 6.34 0.0 TC23 18.11 11.284 K Factor = 5.39 C28 19.750 5.60 18.96 1 T 5.762 3.000 120 11.468 to 0.0 5.762 0.0 TC24 19.750 18.96 1.08 0.0 8.762 0.1024 0.897 Vel = 6.64 0.0 TC24 18.96 12.365 KFactor= 5.39 C29 19.750 5.60 18.96 1 T 5.762 3.000 120 11.468 to 0.0 5.762 0.0 TC24 19.750 18.96 1.08 0.0 8.762 0.1024 0.897 Vel = 6.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - MILLENNIUM FIRE PROTECTION Page 7 HOEHN AUDI CARLSBAD Date 12-18-15 Nodel EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total PfIFt Pf 0.0 TC24 18.96 12.365 KFactor= 5.39 C30 19.750 5.60 24.51 1 T 5.762 0.750 120 19.151 to 0.0 5.762 0.325 TC30 19 24.51 1.08 0.0 6.512 0.1645 1.071 Vel = 8.58 0.0 TC30 24.51 20.547 K Factor = 5.41 C31 19.750 5.60 24.35 1 T 5.762 0.750 120 18.909 to 0.0 5.762 0.325 TC31 19 24.35 1.08 0.0 6.512 0.1625 1.058 Vel = 8.53 0.0 TC31 24.35 20.292 KFactor= 5.41 C32 19.750 5.60 24.35 .- I T 5.762 0.750 120 18.911 to 0.0 5.762 0.325 TC32 19 24.35 1.08 0.0 6.512 0.1626 1.059 Vel = 8.53 0.0 TC32 24.35 20.295 K Factor = 5.41 C33 19.750 5.60 24.56 1 T 5.762 0.750 120 19.228 to 0.0 5.762 0.325 TC33 19 24.56 1.08 0.0 6.512 0.1649 1.074 Vel = 8.60 0.0 TC33 24.56 20.627 K Factor= 5.41 C34 19.750 ' 5.60 25.23 1 1 5.762 0.750 120 20.306 to 0.0 5.762 - 0.325 TC34 19 25.23 1.08 0.0 6.512 0.1735 1.130 Vel = 8.84 0.0 TC34 25.23 21.761 K Factor = 5.41 C35 19.750 5.60 28.07 1 1 5.762 0.750 120 25.128 to 0.0 5.762 0.325 TC35 19 28.07 1.08 0.0 6.512 0.2115 1.377 Vel = 9.83 0.0 TC35 28.07 26.830 K Factor = 5.42 C36 19.750 5.60 28.32 1 1 5.762 0.750 120 25.584 to 0.0 5.762 0.325 TC36 19 28.32 1.08 0.0 6.512 0.2148 1.399 Vel= 9.92 0.0 1C36 28.32 27.308 K.Factor= 5.42 1C20 19.750 37.96 1 T 5.762 0.750 120 12.387 to 0.0 5.762 0.325' TC40 19 37.96 1.08 0.0 6.512 0.3696 2.407 Vel = 13.29 0.0 TC40 37.96 15.119 K Factor = 9.76 TC21 19.750 36.23 1 T 5.762 0.750 120 11.290 to 0.0 5.762 0.325 TC41 19 36.23 1.08 0.0 6.512 0.3391 2.208 Vel = 12.69 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION Page 8 HOEHN AUDI CARLSBAD Date 12-18-15 Node 1 Elevl K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf TC4I 36.23 13.823 K Factor= 9.74 1C22 19.750 36.00 1 T 5.762 0.750 120 11.146 to 0.0 5.762 0.325 TC42 19 36.0 1.08 0.0 6.512 0.3349 2.181 Vel = 12.61 0.0 TC42 36.00 13.652 KFactor= 9.74 1C23 19.750 36.22 1 1 5.762 0.750 120 11.284 to 0.0 5.762 0.325 TC43 19 36.22 1.08 0.0 6.512 0.3389 2.207 Vel = 12.69 0.0 TC43 36.22 13.816 KFactor= 9.74 1C24 19.750 37.93 1 T 5.762, 0.750 120 12.365 to 0.0 5.762 0.325 TC44 19 37.93 1.08 0.0 6.512 0.3689 2.402 Vel = 13.28 0.0 TC44 37.93 15.092 KFactor= 9.76 *LO - MWO 19 63.47 4 T 27.874 3.000 120 37.514 to 0.0 27.874 0.0 FB24 19 ' 63.47 4.31 0.0 30.874 0.0011 0.035 VeI= 1.40 FB24 19 0.0 4 0.0 5.667 120 37.549 to 0.0 0.0 0.0 M5 19 63.47 4.31 0.0 5.667 0.0011 0.006 VeI= 1.40 M5 19 0.0 4 E 13.937 91.500 120 37.555 to 0.0 13.937 0.866 MEO 17 63.47 4.31 0.0 105.437 0.0011 0.119 Vel = 1.40 0.0 MEO 63.47 . 38.540 KFactor= 10.22 *L1 MWI 19 15.65 1.25 T 10.108 22.670 120 36.128 to 0.0 10.108 0.0 TC1 19 15.65 1.536 0.0 32.778 0.0129 0.423 Vel = 2.71 TCI 19 0.0 1.25 0.0 10.000 120 36.551 to 0.0 0.0 0.0 TC2 19 15.65 1.536 0.0 10.000 0.0129 0.129 Vel = 2.71 TC2 19 0.0 1.25 0.0 10.000 120 36.680 to 0.0 0.0 0.0 TC3 19 15.65 1.536 0.0 10.000 0.0129 0.129 Vel = 2.71 TC3 19 0.0 1.25 0.0 10.000 120 36.809 to - 0.0 6.0 0.0 TC4 19 15.65 1.536 0.0 10.000 0.0129 0.129 Vel = 2.71 TC4 19 0.0 1.25 0.0 10.000 120 36.938 to 0.0 0.0 , 0.0 TC5 19 15.65 1.536 0.0 10.000 0.0129 0.129 Vel = 2.71 TCS 19 0.0 1.25 T 10.108 37.250 120 37.067 to . 0.0 10.108 0.866 MEl 17 15.65 1.536 0.0 47.358 0.0129 0.611 Vel = 2.71 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION Page 9 HOEHN AUDI CARLSBAD . Date 12-18-15 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf MEl 15.65 38.544 K Factor = 2.52 *L2 1 MW2 19 23.62 1.25 T 10.108 22.670 120 34.379 to 0.0 10.108 0.0 TC6 19 23.62 1.536 0.0 32.778 0.0276 0.906 Vel = 4.09 TC6 19 0.0 1.25 0.0 10.000 120 35.285 to 0.0 0.0 0.0 TC7 19 23.62 1.536 0.0 10.000 0.0276 0.276 Vel = 4.09 TC7 19 0.0 1.25 0.0 10.000 120 35.561 to 0.0 0.0 0.0 TC8 19 23.62 1.536 0.0 10.000 0.0276 0.276 Vel =. 4.09 TC8 19 0.0 .1.25 0.0 10.000 120 35.837 to 0.0 0.0 0:0 TC9 19 23.62 1.536 0.0 10.000 0.0276 0.276 Vel = 4.09 TC9 19 0.0 1.25 0.0 10.000 120 36.113 to 0.0 0.0 0.0 TC10 19 23.62 1.536 0.0 10.000 0.0277 0.277 Vel = 4.09 TC10 19 0.0 1.25 T 10.108 37.250 120 36.390 to . 0.0 10.108 0.866 ME2 17 23.62 1.536 0.0 47.358 0.0276 1.308 Vel = 4.09 0.0 ME2 23.62 38.564 K Factor= 3.80 *L3 MW3 19 33.07 1.25 T 10.108 42.670 120 31.543 to 0.0 10.108 0.0 TCII 19 33.07 1.536 0.0 52.778 0.0515 2.719 Vel = 5.73 TC11 19 0.0 1.25 0.0 10.000 120 34.262 to 0.0 0.0 0.0 TC12 19 33.07 1.536 0.0 10.000 0.0515 0.515 Vel = 5.73 TC12 19 0.0 1.25 0.0 10.000 '120 34.777 to 0.0 0.0 0.0 TC13 19 33.07 1.536 0.0 10.000 0.0515 0.515 Vel = 5.73 TC13 19 0.0 1.25 T 10.108 37.250 120 35.292 to 0.0 10.108 0.866 ME3 17 33.07 1.536 0.0 47.358 0.0515 2.439 Vel = 5.73 0.0 ME3 33.07 38.597 K Factor= 5.32 *L4 MW4 19 3.71 1.25 T 10.108 32.750 120 26.791 to 0.0 10.108 0.0 TC35 19 3.71 1.536 0.0 42.858 0.0009 0.039 Vel = 0.64 TC35 19 28.07 1.25 0.0 10.000 120 26.830 to 0.0 0.0 0.0 TC36 19 31.78 1.536 0.0 10.000 0.0478 0.478 Vel = 5.50 TC36 19 28.32 1.25 T 10.108 57.250 120 27.308 to 0.0 10.108 0.866 ME4 17 60.1 1.536 0.0 67.358 0.1556 10.479 Vel = 10.41 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 -Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION Page 10 HOEHN AUDI CARLSBAD Date 12-18-15 Nodel Elevl K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf ME4 60.10 38.653 K Factor= 9.67 *L5 MW5 19 -47.10 1.25 T 10.108 2.500 120 21.796 to 0.0 10.108 0.0 TC30 19 -47.1 1.536 0.0 12.608 -0.0991 -1.249 Vel = 8.16 TC30 19 24.50 1.25 0.0 10.000 120 20.547 to 0.0 0.0 0.0 TC31 19 -22.6 1.536 0.0 10.000 -0.0255 -0.255 Vet = 3.91 TC31 19 24.36 1.25 0.0 10.000 120 20.292 to 0.0 0.0 0.0 TC32 19 1.76 1.536 0.0 10.000 0.0003 0.003 Vel = 0.30 TC32 19 24.35 1.25 0.0 10.000 120 20.295 to 0.0 0.0 0.0 TC33 19 26.11 1.536 0.0 10.000 0.0332 0.332 VeI= 4.52 TC33 19 24.55 1.25 0.0 10.000 120 20.627 to 0.0 0.0 0.0 TC34 19 50.66 1.536 0.0 10.000 0.1134 1.134 Vet = 8.77 TC34 19 25.24 1.25 T 10.108 57.250 120 21.761 to 0.0 10.108 0.866 ME5 17 75.9 1.536 0.0 67.358 0.2395 16.135 Vet = 13.14 0.0 ME5 75.90 38.762 K Factor= 12.19 MW6 19 -92.41 1.25 T 10.108 2.500 120 19.465 to 0.0 10.108 0.0 TC40 19 -92.41 1.536 0.0 12.608 -0.3447 -4.346 Vel = 16.00 TC40 19 37.96 1.25 0.0 10.000 120 15.119 to 0.0 0.0 0.0 TC41 19 -54.45 1.536 0.0 10.000 -0.1296 -1.296 Vel = 9.43 TC41 19 36.24 1.25 0.0 10.000 120 13.823 to 0.0 0.0 0.0 TC42 19 -18.21 1.536 0.0 10.000 -0.0171 -0.171 Vet = 3.15 TC42 19 36.00 1.25 0.0 10.000 120 13.652 to 0.0 0.0 0.0 TC43 19 17.79 1.536 0.0 10.000 0.0164 0.164 Vel = 3.08 TC43 19 36.22 1.25 0.0 10.000 120 13.816 to 0.0 0.0 0.0 TC44 19 54.01 1.536 0.0 10.000 0.1276 1.276 Vet = 9.35 TC44 19 37.93 1.25 T 10.108 57.250 120 15.092 to 0.0 10.108 0.866 ME6 17 91.94 1.536 0.0 67.358 0.3415 23.004 Vel = 15.92 0.0 ME6 91.94 38.962 KFactor= 14.73 *M1 MWO 19 -63.47 1.5 T 11.29 3.000 120 37.514 to 0.0 11.290 0.0 MWI 19 -63.47 1.728 0.0 14.290 -0.0970 -1.386 Vet = 8.68 MW1 19 -15.65 1.5 0.0 12.000 120 36.128 to 0.0 0.0 0.0 MW2 19 -79.12 1.728 0.0 12.000 -0.1458 -1.749 Vet = 10.82 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION Page 11 HOEHN AUDI CARLSBAD Date 12-18-15 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. . Total Pf/Ft Pf MW2 19 -23.61 1.5 0.0 12.000 120 34.379 to 0.0 0.0 0.0 MW3 19 -102.73 1.728 0.0 12.000 -0.2363 -2.836 Vel = 14.05 MW3 19 -33.07 1.5 0.0 12.000 120 31.543 to 0.0 0.0 0.0 MW4 19 -135.8 1.728 0.0 12.000 -0.3960 -4.752 VeI= 18.58 MW4 19 -3.71 1.5 0.0 12.000 120 26.791 to 0.0 0.0 0.0 MW5 19 -139.51 1.728 0.0 12.000 -0.4162 -4.995 Vel = 19.09 MW5 19 47.10 1.5 0.0 12.000 120 21.796 to 0.0 0.0 0.0 MW6 19 -92.41 1.728 0.0 12.000 -0.1942 -2.331 VeI= 12.64 0.0 MW6 -92.41 19.465 K Factor = -20.95 *M1 MEO 17 63.47 4 0.0 3.000 120 38.540 to 0.0 0.0 0.0 MEl 17 63.47 4.31 0.0 3.000 0.0013 0.004 Vel = 1.40 MEl 17 15.65 4 0.0 12.000 120 38.544 to 0.0 0.0 0.0 ME2 17 79.12 4.31 0.0 12.000 0.0017 0.020 Vel = 1.74 ME2 17 23.61 4 0.0 12.000 .120 38.564 to 0.0 0.0 0.0 ME3 17 102.73 4.31 0.0 12.000 0.0028 0.033 Vel = 2.26 ME3 17 33.07 4 0.0 12.000 120 38.597 to 0.0 0.0 0.0 ME4 17 135.8 4.31 0.0 12.000 0.0047 0.056 Vel = 2.99 ME4 17 60.11 4 0.0 12.000 120 38.653 to 0.0 0.0 0.0 ME5 17 195.91 4.31 0.0 12.000 0.0091 0.109 Vel = 4.31 ME5 17 75.90 4 0.0 12.000 120 38.762 to 0.0 0.0 0.0 ME6 17 271.81 4.31 0.0 12.000 0.0167 0.200 Vel = 5.98 0.0 ME6 271.81 38.962 KFactor= 43.55 *M3 ME6 17 363.75 6 4E 70.411 61.000 120 38.962 to 0.0 70.411 .0.650 TR2 15.500 363.75 6.357 0.0 131.411 0.0043 0.566 Vel = 3.68 TR2 15.500 0.0 6 2E 35.205. 22.000 120 40.178 to 0.0 35.205 6.496 BR2 .500 363.75 6.357 0.0 57.205 0.0043 0.247 Vel = 3.68 0.0 BR2 363.75 46.921 K Factor= 53.10 BR2 .500 363.75 6 E 15.101 15.000 120 46.921 to 0.0 15.101 0.217 UG3 0 363.75 6.16 0.0 30.101 0.0050 0.151 Vel = 3.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final CIcuIations - Hazen-Williams MILLENNIUM FIRE PROTECTION Page 12 HOEHN AUDI CARLSBAD . . Date 12-18-15 Nodel EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe •******* Notes ****** Node2. EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf UG3 0 0.0 6 2E 35.786 239.290 150 47.289 to 0.0 35.786 1.299 BF3 -3 363.75 5.86 0.0 275.076. 0.0042 1.166 Vel = 4.33 BF3 -3 0.0 6 Zic 0.0 12.000 140 49.754 to 2E 40.168 83.205 3.183 * * Fixed Loss = 3.183 BF4 -3 363.75 6.16 T 43.037 95.205 0.0038 0.359 Vel = 3.92 BF4 -3 0.0 8 T 43.857 37.710 150 53.296 to G 5.012 48.869 0.0 UG4 -3 363.75 7.68 0.0 86.579 0.0011 0.098 Vel = 2.52 UG4 -3 0.0 8 T 43.857 71.210 150 53.394 to G 5.012 48.869 -1.299 SRC2 0 363.75 7.68 0.0 120.079 0.0011 0.136 Vel = 2.52 250.00 Qa = 250.00 SRC2 613.75 52.231 KFactor= 84.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087