Loading...
HomeMy WebLinkAbout5620 PASEO DEL NORTE; ; AS150315; Permit2/22/24,2:01 PM AS150315 Permit Data City of Carlsbad Sprinkler Permit 5620 PASEO DEL Job Address: NORTE Permit Type: SPRINK Parcel No: 2110222200 Lot #: 0 Reference No.: Permit No: AS150315 Status: ISSUED Applied 10/15/2015 Approved: 10/16/2015 Issued: 10/16/2015 PC #: Inspector: Project Title: CONVERSE DENSITY UPGRADE PROVIDE DESIGN, MATERIALS, AND INSTALLATION LABOR TO REMOVE AND PLUG EXISTING SPRINKLER HEADS. TIE INTO EXISTING MAIN IN STE 116C. PROVIDE A NEW DENSITY UPGRADE CALC EXTRA HAZARD GROUP 2 AT .45/3000 SF IN SALES AREA AND ENTRIE STORAGE ROOM EXIT HALL, TOILET AND DRESSING ROOMS SHALL BE LIGHT HAZARD. Applicant: COSCO FIRE PROTECTION 4990 GREEN CRAIG LN SAN DIEGO, CA 858-444-2000 Owner: RUBYS DINER CPG CARLSBAD HOLDINGS L L C CPG PARTNERS LP P0 BOX 6120 INDIANAPOLIS IN Fees ($) Add'l Fees ($) Total ($) Balance ($) 213 0 213 0 about:blank 1/1 .....e.. cosco S. ..IS. S •1•.; 00 Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lie.: C-16 #577621 www.coscoflre.com MATERIAL SUBMITTAL & CALCULATIONS Date: 07/30/15 CONVERSE 5620 PASEO DEL NORTE SUITE 114C CARLSBAD, CA 92008 JOB # 10.CD_5630 LA All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. APPROSISUBMITTEDTp 0 3 1 curr nt appl .ihk cod Ln c and sl,u d.inls in _____________ him. •flic in/h i c tm 1;i% hi CARL$ P 0 IRE'D R' ffmit -4 n rclict em iIit rn her mu cimnilacior or I ph Imssiofl.il CIIL'ineer iii ai'cluiec( liii .O!h re%p(hIlMh IitI CihInl)IihiIiCC tviih miid ciitI zuuid si,timd;i iictudiui the huildiuig code or for au responmihulIy tiLl hCuCuiChe. errors. ihlhlisSihuhlS or uitiicnce hi Iii - 1,Ians%' hethr or 11 it muid in this review. - i)utr: q T44 (( Reviewer/ Submitted by: FELIPE RICitiiLNi) ,Pi(('AI. TZ Ai'il?UV\i.. AS Ni )Tli) Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle June 28, 2013 Sprinkler 13e STANDARD RESPONSE ELO UPRIGHT SPRINKLER "J II(IIS16I (STORAGE-DENSITY/AREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION The Viking Standard Response ELO Upright Sprinkler VK530 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. The special Polyester, PTFE, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no ap- proval classification for PTFE and Polyester coatings as corrosion resistant.) The extra-large orifice provides greater flows at lower pressures than standard orifice or large orifice sprinklers. This feature allows reduced pipe sizing for hydraulically calculated sprinkler systems, which require high densities of water. Viking Standard - Response Extra-Large Orifice Sprinklers may eliminate the need for a fire pump or reduce the size of the pump if it is required. On existing systems, replacing large orifice sprinklers with extra-large orifice sprinklers may provide the higher densities required to allow an increase in the hazard classification of an occupancy. Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions below. LISTINGS AND APPROVALS cULus Listed: Category VNIV L FM Approved: Class 2009 NOTE: Upright Sprinkler VK530 is cULus Listed as Specific Application Sprinklers as indicated in Design Criteria on page 13g. Refer to Approval Chart I and Design Criteria on page 13g for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 13h for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1992. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to Viking Technical Data may be found on 500 psi (34.5 bar). The Viking Corporation's Web site at Thread size: 3/4" NPT or 20 mm BSP http:IIwww.vikinggroupinc.com. Nominal K-Factor: 11.2 U.S. (161.3 metric) The Web site may include a more recent *Metnc K-factor measurement shown is when pressure is measured in Bar. When pressure is edition of this Technical Data Page. measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: 2-5/16" (58.7 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 - Bulb: Glass, nominal 5 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Compression Screw: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sonnklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Extra-Large Orifice Upright Sprinkler VK530 by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Form No. F_010692 Replaces page 13e-i dated May 28, 2010. (Added ENT Finish and removed VK536.) Sprinkler 13f June 28, 2013 STANDARD RESPONSE ELO UPRIGHT SPRINKLER N4 Kj FJG® VK530 (STORAGE-DENSITYIAREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Finish Suffix: Brass = A, Chrome = F, White Polyester = M-M, Black Polyester = M-/B, Black PTFE = N, Wax Coated = C, ENT =JN Temperature Suffix (°F/°C): 155°/680 = B. 1750/790 = D, 200°I93° = E, 286°/141° = G, OPEN = Z (PTFE only). For example, sprinkler VK530 with a Brass finish and a 155 °F/68 "C temperature rating = Part No. 09679AB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 05118CW/B (available since 1981). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Standard Response Extra-Large Orifice Upright Sprinkler VK530 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. June 28, 2013 Sprinkler 13g STANDARD RESPONSE ELO UPRIGHT SPRINKLER 4J II(INIG® VK530 (STORAGE-DENSITYIAREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135°F (570C). Wax-Coated Brass for sprinklers with the following temperature ratings: 155 OF (68 °C) Lt. Brown Wax 175 OF (79 °C) Brown Wax 200 OF (93 °C) Brown Wax 286 OF (141 °C) Ok. Brown Wax4 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For PTFE coated open sprinklers only, the waterway is coated. For all ENT coated sprinklers, the waterway is coated. Wax melting point is 170 OF (76 °C) for 286 OF (141 °C) temperature rated sprinklers. Protective f '._ Sprinkler Protective Wrench ShieLcl Sprinkler _____________ Ft Cup Figure 1: Upright Sprinkler VK530 and Wrench 05118CW!B Sprinkler 13h June 28, 2013 SJ IF(II1 STANDARD RESPONSE A 94 ELO UPRIGHT SPRINKLER (STORAGE-DENSITYIAREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart I (UL) ;;= TWwwalWO KEY Standard Response Exft-Uqp Orifice Upright Sprinkler VK$30 I ANX EmaAdum (ffeaft")l Maximum 17$ PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvalss Number SIN Style (Refer also to Design Criteria below.) NPT BSP U.S. metric- Inches mm cULus4 NYC 09679 VK530 Upright 3/4" -- 11.2 161.3 2-5/16 58.7 A3, Bi, C2, B4 See Footnote 6. 14819 VK530 I Upright -- 20 mm 11.2 161.3 1 2-5/16 58.7 1 A3, 131, C2, B4 -- Approved Temperature Ratings Approved Finishes A - 286 °F (141 °C) 1 - Brass, Chrome, White Polyesters, Black Polyesters, and Black PTFE5 B - 155°F (68 °C), 175 °F (79 °C), 200°F 2 - Wax-Coated Brass (corrosion resistant) (93 "C), and 286 °F (141 °C) 3- Brass with 200 °F (93 °C) Wax Coating (corrosion resistant); Maximum ambient ceiling temperature = 150 C - 155 "F (68 °C), 175 "F (79 "C), and "F (65 °C). 200 °F (93 °C) 4 - ENT5 Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 MetricK-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5CULUS Listed as corrosion-resistant. 6Meets New York City requirements, effective July 1, 2008. DESIGN CRITERIA - UL (Also refer to Approval Chart I above.) cULus Listina Reauirements: Standard Response Extra-Large Orifice Upright Sprinkler VK530 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard spray upright sprinklers: Designed for use in hazard occupancies up to and including Extra-Hazard Group II with a minimum operating pressure of 7 psi (0.5 bar). Sprinkler VK530 is also cULus Listed for use in High-Piled Storage Occupancies as defined in NFPA 13 with a minimum operating pressure of 7 psi (0.5 bar). The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray upright sprinklers must be followed. Also: When acceptable to the Authority Having Jurisdiction, Viking Standard Response Extra-Large Orifice Sprinkler VK530 may be used as specific- application heads with a density of .6/2000 ft.2 for wet systems or .6/2600 ft.2 for dry systems to protect single-, double-, multiple-row, and port- able rack storage of Class l-IV, Group A and B Plastics, cartoned, expanded or unexpanded, as well as exposed unexpanded when the following conditions are met: A maximum storage height of 20 ft. (6.1 m). A maximum ceiling height of 25 ft. (7.6 m). A 36-inch (914 mm) minimum clearance from the deflector to the top of storage. Otherwise, design to the appropriate density/area requirements. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. June 28, 2013 Sprinker 131 STANDARD RESPONSE ELO UPRIGHT SPRINKLER NIKJNG4 ® VK530 (STORAGE-DENSITYIAREA) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart 2 (FM) Standard Response Extra-Large orifice Upright Sprinkler VK530 TumpleMile I 4 I I A1x4- El Maximum 175 PSI (12 Bar) WWP Base Part I I I Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Sprinkler Style I I I NPT I BSP U.S. I metric2 Inches I mm (Refer also to Design Criteria below.) 09679 I VK530 I Upright 3/4° -- 11.2 161.3 2-5/16 I 58.7 Al, A2 14819 VK530 Upright -- 20 mm 11.2 161.3 2-5/16 58.7 Al, A2 Approved Finishes Approved Temperature Ratings A - 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F 1 - Brass and Chrome - ENT4 (141 °C) Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 2Metijc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Other approvals may be in process. FM Approved as corrosion-resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Anoroval Requirements: Standard Response Extra-Large Orifice Upright Sprinkler VK530 is FM Approved as a standard response upright Non-Storage sprinkler, and as a standard response upright Storage sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. LL±4.J (44.5 mm) 2-5/16" (59 mm) \_ 3/4" Upright Sprinkler (20 mm) 09679 (VK530) Figure 2: Sprinkler Dimensions Form No. F_010692 Replaces page 13e-i dated May 28, 2010. (Added ENT Finish and removed VK536.) December 4, 2013 Sprinkler 41a MICROFAST® AND MicrofastHP® QUICK SJ I I(J F1Gi RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfasr and MicrofastHPe Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resist- ant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1 EC-certificates of conformity 0786-CPD40130, 0786-CPD40170 and 0786-CPD- 40279, 0832-CPD-2001, and 0832-CPD-2003 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart I and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http:IIwwwvikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: Refer to the Approval Charts cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12979 and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 12979, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT coated. Form No F 081296 Replaces page 41a-f, dated June 28, 2013. - (Changed 06932B to VK3311.) Wrench Flt Project no WON i 0 t Sprinkl Shielo Protective Sprinkler Cop Sprinkler 41 b December 4, 2013 MICROFASTO AND MicrofastHP® QUICK JII(I60 RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Microfaste and MicrofastHPa Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-NV, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B. 175°F (79 °C) = D, 200°F (93 °C) = E, and 286°F (141 °C) = C For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 OF (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B* (available since 2011) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) *A h/2fl ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. I S. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance require- ments. AVAILABILITY The Viking Microfast® and MicrofastHPa Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 10896W/13 December 4, 2013 Sprinkler 41c MICROFAST® AND MicrofastHP® QUICK \JII(JIS1 ® RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES - Ordinary 135 OF (57 °C) 100 OF (38 °C) ' Orange Ordinary 155 OF (68 'C) 100 OF (38 'C) Red Intermediate 175 OF (79 'C) 150 OF (65 'C) Yellow Intermediate 200 OF (93 'C) 150 OF (65 'C) Green High 286 OF (141 'C) 225 OF (107 'C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 OF (57 'C). Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. I If SprinkLer Wrench 16036W/Bww f or Installing recessed tif] [1JJ pendent sprinklers * 'N A 1/2 ratchet is required (not evaileble from Viking). Ii Carefully slide The f wrench sideways I around The protective cap, ensuring engage- ment with the sprinkler wrench fLats. Figure 2: Wrench 16036W18 for Recessed Pendent Sprinklers Sprinkler 41d December 4, 2013 MICROFAST® AND N41 KJ MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 TeleDhone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com Approval Chart 1(UL)ci ___ X4—L idmt' 1*1111 (12b.0WWP Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metric- Inches mm cULus4 I NYC- VdS LPCB I Standard Orifice 12979 VK302 1 1/2" 15 mm 5.6 80.6 1 2-1/4° 57 AIX, B1Y, C4, E4Z AIX, B1Y -- - - - 18021 VK302 j 1/2" 15 mm 5.6 80.6 J 2-1/4" 58 AIX, B1Y AIX, B1Y A2 A2X, B2Y C2X, E2Y11 C2X, E2Y14 Large Orifice 06666B VK352 3/4" 20 mm 8.0 1 115.2 2-3/8" 60 1 AIX, BIY, C4, E4ZJ AIX, BIY I A2 A2X C21' -- 06765B'5 VK352 1/2" 15mm 8.0 ] 115.2 2-3/8" 60 J AIX, B1Y, C4, E4Z I AIX, B1Y I .A2 -- A212 -- Small Orifice" 06718B9 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AIX, B1Y AIX, B1Y - -- -- -- 06720139 VK331 1/2" 15 mm 4.2 57 2-1/4" 58 AIX, B1Y AIX, BIY -- - -- -- 06932B VK3311 - 10 mm 4.2 57 2-3/8" 60 -- - A2 -- G313 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S.metric2 Inches mm cULus4 NYC'- I VdS 1 LPCB 1 (( 1 • 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" j58 1 AIX, B1Y AIX -- Maximum 250 PSI (17 bar) WWP Small Orifice9 1229010 VK342 1/2" 115 mm 2.8 40.3 2-3/16" 1 56 AiX, B1Y AIX -- -- I -- I - Approved Temperature Ratings Approved Escutcheons A - 135°F (57 °C), 155°F (68 "C), 175 "F (79 "C), 200°F (93 °C), and 286 °F (141 °C) Approved Finishes X - Standard surface-mounted escutcheon or B - 135 °F (57 °C), 155°F (68 °C), 175°F (79 °C), and 200 °F (93 1 - Brass, Chrome, White Polvester 7, Black Polyester87, and Black PTFE6 the Viking Microfast Model F-i Adjustable Escutcheon C - 155 °F (68 °C), 175 °F (79 "C), 200 °F (93 °C), and 286 °F (141 2 - Brass, Chrome, White Polyester7, and Black V - Standard surface-mounted escutcheon or °C) Polyester" the Viking Microfast' Model F-I Adjustable D - 135 "F (57 °C), 155 °F (68 °C), 175 °F (79 °C). and 286 °F (141 3- Brass and Chrome Escutcheon or recessed with the Viking C) Micromatic Model E-1. E-2, or E-3 Recessed E - 155°F (68 °C), 175°F (79 °C), and 200°F (93 °C) 4 - ENT6 Escutcheon F - 155 "F (68 °C), 175 °F (79 °C), and 286°F (141 °C) Z - Standard surface-mounted escutcheon or re- cessed with the Viking Micromatice Model E-I G -155 °F(68 "C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the some Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems Only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. O The sprinkler orifice is bushed. '°Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. "CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40279. 13 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40130 and 0786-CPD-40170. 14 ØMED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. 15 The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. 1/2 (15 mm) __________ NPT I 1 2-1/4' 1-5/8' (58 mm) (41 mm) W A- ____ Pendent Sprinkler Installed with a standard 1/8' surface- mounted escutcheon. Maximum L Installed with a Microfast Model F-i Adjustable Escutcheon December 4, 2013 Sprinkler 41e MICROFAST® AND MicrofastHP® QUICK \1H(IIs1E ® RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA - UL (Also refer toft,provalChaiIIcn page 41d) cULus Listing Reauirements: Microfast® and MicrofastHP5 Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (58.7 mm) minimum 2-1/8' I 2-1/2' (63.5 mm) maximum w Note: At maximum, adapter is exposed 1/2' (12.7 mm) from face of ceiling. Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8' Ceiling Opening Size: 2-1/8' (54 mm) 2-5/16' (58.7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum 1-1/8' (28.6 mm) Minimum 1-1/8' (28.6 mm) Minimum Installed with a Micromatic Mode[ E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons Sprinkler 41f December 4, 2013 MICROFAST® AND ""I II(lISlI® l:II[•'w MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) ,, ..y Naximàn 115 P51 (12 bar) WWP Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Base Part No.' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 A2X, MY, C3, D3Z 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, 132Y Large Orifice 066666 VK352 3/4" 20 mm 8.0 115.2 . 2-3/8" 60 A2X, B2Y, C3, D3Z 06765B7 VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A2X, MY, C3, D3Z Small Orifice4 06718136 VK329 1/2" 115 mm 2.8 40.3 2-3/16" 56 AiX Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C) 155 °F (68 °C) 175 °F (79 °C) ' X - Standard surface-mounted escutcheon or the Viking 200 °F (93 °C), and 286 °F (141 °C) Approved Finishes Microfast5 Model F-i Adjustable Escutcheon B - 135°F (57 °C), 155 °F (68 °C), 175°F (79 °C), I - Brass and Chrome Y - Standard surface-mounted escutcheon or the and 200 °F (93 °C) 2 - Brass, Chrome, White Polyester5, and Viking Microfast5 Model F-i Adjustable Escutcheon C- 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), Black Polyester5 or recessed with the Viking Micromatic5 Model E-i, and 286 °F (141 °C) 3 - ENT8 E-2, or E-3 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F Z - Standard surface-mounted escutcheon or recessed (93 C) with the Viking Micromatic5 Model E-1 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other colors are available on request with the same Listings and Approvals as the standard colors. The sprinkler orifice is bushed. The 1/2" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. 8 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from cULus and/or NFPA criteria. tSpnnklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for gen- eral care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated June 28, 2013. (Changed 06932B to VK3311.) i &Y-~kVA&7AA1rfAf fA! &Xv#A&mimidLTAs Schedule-1O/Schedule-40 - ABFII fu ndlFtl pier When you specify Allied Schedule-10/5chedule-40 - ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/5chedu1e-40 - ABFII gives you the extra quality assurance you demand. Our Sch-10 (11/4"-8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-1O/Schedule-40 -ABFII product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. > Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFII". In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* > American Made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ) Specifications & Approvals Schedule-10/Schedule-40-ABFII pipe are in compliance with the following: ASTM A-135, Type E Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture See ABFII warranty NPS 'r Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/nn - 25 1.049 26.6 1.680 2.05 1 - 2.5 3.05 P14" 1.380 2.270 2.93 1 32 35.1 4.36 4.36 - 1½" 40 1.610 40.9 2.720 3.61 1 4.0 -5.37 - 50 2.067 52.5 3.650 5.13 1 7.63 1 - 5.4 2½" 2.469 5.790 7.86 1 65 62.7 8.6 11.73 - NPS Ii Nominal I.D. Wt. wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn - 1'/4" 1.442 1.810 2.525 7.0955 32 36.6 2.7 3.75 - 1½" 1.682 2.080 3.04 5.6570 40 42.7 3.1 4.52 - 50 2.157 2.640 4.22 4.5827 - 54.8 3.9 6.28 2½" 65 2.635 66.9 3.530 5.3 5.89 3.5196 8.77 - 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 100 4.260 108.2 5.610 8.3 11.78 1.6020 17.53 - 125 5.295 134.5 7.77 17.33 1.4874 11.56 25.80 - 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 24.5 59.75 - CPPeVLD qla llied Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com 161005 Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT" Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 ABRMDGIA 02011 Atkore International, Inc. All Rights Reserved. STP-S5-3-1 105 C.I. THREADED FITTINGS FITTINGS (9 (q~ <*> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON CROSS NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIM BISIONS WEGK EACH PIECE A B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 . 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1 1.73 2.02 2.75 CAST IRON REDUCING TEE F NOMINAL SIZE (INCH) ITEM ' CODE MAX. ' WORKING P.S.I. I DIMB1SIONS I WBGIfl EACH PIECE A I B C 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X314X1 CT323 300 1.50 1.45 1.50 1.18 IXiXi 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 174X1X1/2 CT431 NF---T-Tr- 1.26 1.53 1.17 1 1/4X1 X3/4 CT432 300 1.45 1.37 1.62 1.38 1 114X1X1 CT433 1 300 1.58 1.50 1.57 1 1.47-- - - - - T1/4 CT434 1 300 1.75 1.67 1.75 1.80 1 1I4X1X1 Im C1435 1 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 1 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X314 CT442 1 300 1.45 1.45 1.62 1.54 1 1/411 1/4X1 CT443 1 300 1.58 1.58 TT 1.65 -TT/4r1 114X1 1/2 CT445 300 TW 1.88 tF 2.21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 Tö 2.55 1 1/2X1 X1/2 CT531 300 T4T 1.34 -ir 1.41 1 1!2X1X3/4 CT532 300 131 1.37 i.fb 1.65 1 1/2X1X1 CT533 300 1351.50 TF 1.65 1 1/2X1X1 1/4 CT534 300 111 1.67 TF 2.00 1 112X1X1 1/2 CT535 300 tT1 1.80 14 2.30 1 112X1 1/4X1/2 CT5 1 300 T41 1.34 1.58 1 112X1 114X314 CT542 300 13T 1.45 171 1.72 1 112X1 1/4X1 CT543 300 1.65 1.58 1.85 1 1/2x1 1/4x1 1/4 C1544 300 1.82 1.75 TW -F2-2- 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 1 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 114X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1 1.90 1 1.90 2.10 3.32 2X2X1 1/2 CT665 300 1 2.02 1 2.02 2.16 3.72 2x2x2 1/2 I CT667 300 1 2.60 1 2.60 2.39 5.10 Page 39 CAST I '(.]II!DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIM IONS WEIGHT - A - B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 1 CB900551 300 1.94 1.94 1.80 2 CB900661 300 2.25 2.25 2.90 21/2 CB90077 300 2.70 2.70 4.75 Fa _q 1 L------J--i CAST1IRONIRED. COU U K NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIM B4SION WEIGHT EACH A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 fr-B-I [71:Tfr . CASTIIRON STRAIGHT1i NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSIONS WBGIfr EACH PIECE A B 1 CT333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11/2 CT555 300 1.94 1.94 2.51 2 C1666 300 2.25 2.25 3.96 21/2 CT777 300 2.70 2.70 6.45 tq4 I RON U :ji)!T NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WBGIrr EACH PIECE - A - B 1 CB45033 300 1.12 1.12 0.84 1114 C1345044 300 1.29 1.29 1.40 1112 1 CB450551 300 1 1.43 1.43 1 1.80 2 1 CB450661 300 1 1.68 1 1.68 1 2.79 C.I. THREADED FITTINGS FITTINGS () (I) 4 <> Di.iiou fSWrPipe Pmd,ctx LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME rATA 616.14. THREADS ARE NPT PER ANSI/ASME 61.20.1. I CAST 1IIRON IRED. ITEM CODE 90 D MAX. I WORKING P.S.I. 3* DIM B4S5] WAGHI I EACH PIECE I NOMINAL I SIZE (INCH) - A B 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 114X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 C690042 300 1.45 1.62 1.13 1 1!4X1 CB90043 300 1.58 1.67 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 1/2X1 1/4 C690054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X314 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 1 CB900651 300 202 2.16 2.60 Page 38 CASTIIIRON IPLUGS T I NOMINAL SIZE (INCH) I ITEM CODE U I MAX. WORKING P.S.I. IDIMIONI WEIGHT I EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPLOO2 300 1.07 0.17 1 CPL003 300 IN 0.28 11/4 CPLOO4 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 FireLock® Rigid Coupling STYLE 005 WITH VIC.PLUS'M GASKET SYSTEM (NORTH AMERICA ONLY) FireLockO Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire protection systems. Vic-PIusTM Gasket System: In North America, Victaulic offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The VicPlusTM System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. <> I!!) ('l5 LPC and VdS Approved, see notes on page 4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS .PATE! (LwIus Systm LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure — Psi Tama Related Working MM Pressure — 300 N/A psi Related Working (M Qb Pressure — psi 5 1Ve-3 175 175 1 175 EL 116-2 N/A MT 116-2 300 N/A N/A 116-4 350 350 350 ET 116-2 300 N/A N/A STF 1Y4-4 N/A N/A 300 10,40 5-8 300 300 300 EZ 4-6 300# N/A 300 Steady116-2 N/A N/A 300 BLT P/e-2 300 300 N/A FF 114-4 N/A N/A 300 TF 3-8 N/A N/A 300 DF 1V4-4 300 300 300 GAL-7 114-2 300 N/A N/A WLS W4-2 IIA -3 300 300 N/A OT 11/4-2 300 300 N/A MIT 1 14 - 21 300 N/A I N/A XL 300 300 300 EF 1V-4 175@ N/A 175 MF IY4-41 300 N/A 1 300' FM approved for service in 1 Va - 4' pipe. # UL Listed for service up to 4 pipe only. @ UL Listed for service up to 3' only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location Approved Date__________________________________ www.victaulic.com \J(tauIiC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I 10.02_1 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) Size Actual Nominal On I side Max. Work Pressure Ma x End Load ' Allo~. Pipe End Sep. I Bolt/Nut@ No - Size Dimensions - inchesimm Approx. Wgt. Each Size Diameter Inches/mm Inches/mm 1¼ 1.660 I PSI kPa 350 Lbs. IN I755I Inches mm 0.05 Inches mm I X Z 2.75 4.50 1.88 Lbs. kg 1.2 32 42.4 2413 3370 1.2 2-~x 214 70 114 148 0.5 1½ 1.900 350 990 0.05 3.00 4.75 1.88 1.2 40 48.3 2413 4415 1.2 2-~x214 76 121 148 0.5 2 2.375 350 1550 0.07 3.50 5.25 1.88 1.6 50 603 2413 6900 1.7 2- % x 2½ 89 133 148 0.7 2½ 2.875 350 2270 0.07 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 2-3Ax2½ 102 146 148 .09 76.1 mm 3.000 350 2475 0.07 2-%x2½ 4.13 5.75 1.88 1.9 76.1 2413 11010 1.7 105 146 148 0.9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 2-14 x 21/2 118 156 148 1.0 4 4.500 350 5565 0.16 2 -~x 216 5.75 7.25 2.13 3.1 100 114.3 2413 24770 4.1 146 184 54 1.4 108.0 mm 4.250 300 4255 0.16 5.63 7.25 2.13 3.1 108.0 2068 18940 4.1 2-3Ax2½ 143 184 54 1.4 5 5.563 300 7290 0.16 2-%x3 6.88 9.00 2.13 45 125 141.3 2068 32445 4.1 175 229 54 2.0 133.0mm 5.250 300 6495 0.16 2-½x2~ 6.63 9.00 2.13 4.5 133.0 2068 28900 4.1 168 229 54 2.0 139.7mm 5.500 300 7125 0.16 2-½x23A 6.88 9.00 2.13 4.8 139.7 2068 31715 4.1 175 229 54 2.2 6 6.625 300 10340 0.16 2-½x3 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 203 254 53 2.3 159.0mm 6.250 300 9200 0.16 7.63 10.00 2.13 55 159.0 2068 40955 4.1 2-1hx2-% 194 254 54 25 165.1 mm 6.500 300 9955 0.16 2-½x3 8.15 10.00 2.13 55 165.1 2068 44295 4.1 207 254 54 23 8 8.625 300 17525 0.19 2-~x4¼ 10.50 13.14 2.63 113 200 219.1 2068 78000 4.8 267 334 67 5.1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar/175 psi. DIMENSIONS E41' 0' 11 Rated for wet and dry sprinkler systems at 350p51/2413kPa for 1¼ - 4/32 - 100mm sizes and 300 psi /2068kPa for 4 V4 - 87108 - 200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. www.victaulic.com 'j?c. tauIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02_2 REV-1 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-Plus'" Gasket System (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Vic-Plus'" Gasket System, requiring no field lubrication for most installation conditions. Grade 'L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade 'E" Type A FlushSeale Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Standard gasket and FlushSeal gasket approved for dry pipe systems to -40°F/-40°C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0e17I_18C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV-1 jtauIicr 10.60_3 FireLock® Rigid Coupling STYLE 005 WITH VIC.PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. III 11111111 IllIllIllIlUllIll II 111111 III lii WCAS-697KR4 For complete contact information, visit www.victaulic.com 10.02 1538 REV I UPDATED 912006 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. X, A st a -U1 ii 10.02 FireLock® FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location Date______________________________ Approved Date______________________________ www.victaulic.com vICTAULIC IS REGISTERED TRADEMARK OF VICTAuLIC COMPANY. 02009 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV_H \4taulicr 10.03_i IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS FireLock® Fittings DIMENSIONS I.0 to El WE NO. 001 10.03 to I Cto' GiIL !IIc _ cb r I-to E NO. 003 NO. 002 NO. 006 . t L.. J L No. 006 I ½ 32 1.660 42.4 - - - - - - 08 21 0.3 0.1 1 ½ 40 1.900 48.3 - - - - - - - - - - - - 0.82 21 0.4 0.2 2 50 2.375 60.3 2.75 70 1.7 0.8 2.00 51 1.8 0.8 2.75 70 2.4 1.1 0.88 22 0.6 0.3 2½ 65 2.875 73.0 3.00 76 3.1 1.4 2.25 57 2.2 1.0 3.00 76 3.6 1.6 0.88 22 1.0 0.5 76.1 6. mm 3.000 76.1 3.00 76 330 13 2.25 57 2.4 1.1 - - - - 3 80 3.500 88.9 3.38 86 4.0 1.8 2.50 64 3.1 1.4 338 86 5.3 2.4 0.88 22 1.2 05 108mm 4.250 108.0 4.00 102 5.7 2.6 3.00 76 5.1 2.3 4.00 102 7.5 3.4 - - 4 100 4.500 1143 4.00 102 6.7 3.0 3.00 76 5.6 23 4.00 102 8.7 3.9 1.00 25 2.4 1.1 5 125 5.563 141.3 4.88 124 12.6 5.7 3.25 83 8.3 3.8 4.88 124 15.7 7.1 1.00 25 4.1 1.9 159mm 6.250 158.8 530 140 12.6 5.7 330 89 9.2 4.2 530 140 17.9 8 .0 - - 6 150 6.625 1683 530 1 140 183 1 8.3 3.50 89 11.7 1 5.3 530 140 22.7 1 10.3 1.00 25 5.9 2.7 8 200 8.625 219.1 6.81 173 255 11.6 4.25 108 20.4 9.3 6.94 176 38.7 17.6 1.13 29 12.7 5.8 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.03_2 4tauIicr REV_H IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA Frictional Resistance Size iittm. Actual o. 002 Nomin Outside aight Tee Size Diameter Inches Inches No 001 No. 003 m. .1, 90 Elbow 45 Elbow Branch Run 1 4 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 05 I ½ 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 85 3.5 50 60.3 1.1 0.5 2.6 1.1 2.875 43 2.2 10.8 4.3 2½ 65 73.0 1.3 0.7 33 13 3.000 4.5 2.3 11.0 4.5 76.1 mm 76.1 1.4 0.7 3.4 14 3 3.500 5.0 2.6 13.0 5.0 80 - 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108 mm 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 1143 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 13 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 1683 3.0 1.5 7.6 3.0 8.625 13.0 5.0 33.0 13.0 8 200 219.1 4.0 15 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com . ,_,sstuIi VICTAULIC IS REGISTERED TRADEMARK OF VICTALILIC COMPANY. © 2009 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_H 10.03_3 FireLock® Fittings GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings, use FireLock No. 006 end caps containing the 'EZ" marking on the inside face or No. 60 end caps containing the 'QV EZ marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. III liii 11111111 IUIIIIII 111111111 III WCAS-7MX2JY For complete contact information, visit www.victaulic.com ,4'ctauiic 10.03 1539 REV H UPDATED 112009 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 29 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 Fig. 200F ri '555 / S S S Fig. 200-1 to 200-2 Fig. 200-21h to 200-8 Fig. 200 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 BLihè by ET'N' Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B311ONF) ®TOLcO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B311ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B311ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut FM Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUl) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) - - Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FMDS2-0. - Fig. 200C Part No. Pipe Size in. (mm) Rod Size in. A (mm) in. B (mm) Approx. Wt./100 lbs. (kg) L2oo/z '/2(15) /8'6 3V8°(79A)2 /8' (66.1) _iL..J.°L_J 200-/4 3/4" (20) /8-16 31/e' (79.4) 21/2" (63.5) 11 (5.0) 200-1 1"(25)/8'-16 3 /8'(85.1)2/t'_(66.1)12(5.5)__j 200-11/4 11/4u (32) /8"-16 33/4' (94.0) 2/a" (73.0) 13 (5.9) I_200-1'/2 11/2 (40)/8"-16 31/r (984)2W' (73.0) 14 (&_J 200-2 2' (50) /8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-2'/2 2'I2'(65)3/e"-16 5 /8"(142.9)4'/8° (104.7)27(12.3) 200-3 3' (75) 3/8 -16 51/g' (149.1) 4" (101.6) 29 (13.3) 200-3'I2 31/2" (90) /e"-16 7/8' (187.3) 5'/4'(133.3) 34 (15.6)JJ 200-4 4" (100) /8°-16 73/8' (187,3) 5" (127.0) 35 (16.0) [200-5 (125) '/2"-13 9/8' 1231.8) 61/4" (158.7)66 l30.2l_J 200-6 (150) 1/2'-13 10'/o" (257.2) 6/4" (171.4) 73 (33.4) 1 200-8 8" (200) 1/2 -13 131/8" (333.4) 8/4' (222.2) 136 (62.3) I Fig. 2005 Part No. Threads Recommended Load Approx. Wt.I100 Ft. & Size Per Inch Lbs. IN) Lbs. (kg) I ATR 1/C x L' 20 240 (1.07) 12 (5.44) ] ATR 3/g" x 'I.' 16 730 (3.24) 29 (13.15) ATR /2 x 'L' 13 1350 (6.00) 53 (24.04) ATR I8" x 'L' 11 2160 (9.60) 89 (40.37) TATR 34" x 'L' 10 3230 (14.37) 123 (55.79) ATR I8" x 'L' 9 4480 (19.93) 110 (77.11) Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B3205L - Threaded Rod (right & left hand threads) Size Range: /°-16 thru 3°4 rod Material: Steel _""TL Function: Recommended for use as a hanger support in hanger assemblies. Specify Length Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) - TL Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and "°' A materials. •\__ Thread Size Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length IL 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-318 x L /8-16 21/2' (63.5) 730 (3.25) 572 (2.54) B3205-1I2 x 'L' '/2-13 21/2' (63.5) 1350 (6.00) 1051 (4.70) B3205-5/e x L 5/e'-11 21/2' (63.5) 2160 (9.61) 1692 (7.52) B3205-3/x L /4-10 3' (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x 'L' /8"-9 31I2 (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8°-16 thru 11/2°6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. For larger sizes consult full line pipe hanger catalog. B-. - ne All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. LI bvEtóN 94 Fire Protection Solutions All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 86 Fire Protection Solutions BLine by E1.N Upper Attachments Fig. 15- Swivel Attachment Size Range: - /8'-16 Rod Attachment Material: Steel Function: Recommended applications for this product: May be used as a Branch Line Restraint for structural attachment to anchor bolt, beam clamp, etc. May be used in a pitched or sloped roof application, to meet requirements of NFPA 13 (2010) 9.1.2.6. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support up to 4' (1 00mm) pipe. Finish: Electro-Galvanized Weight: Approx. Wt./100 - 13.3 Lbs. (6.0kg) Order By: Figure number Patent: #7,887,248 P Fig. 75 Swivel T I : ....... Ceiling Plate 78AllSteel J 1 Attachment Fig. ED All Threaded Rod Adjustable Band Hanger Fig. 25 25 Surge Restrainer May be used as a structural attachment component of a branch line restraint Fig. SSXT Reversible Beam Clamp W-Beam Fig. 75 Swivel Attachment All Threaded Rod May be used with a pitched roof application, to meet requirements of NFPA 13 (2010) Sec. 9.1.2.5. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions BLiflè byE14J Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line 63183) Size Range: 3/4 (20mm) thru 2" (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4' x 1 tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Pipe Size A Part No. in. (mm) in. (mm) B in. (mm) C in. (mm) Max. Hanger Spacing Ft. (m) Fastener Hex Head Size in. (mm) Approx. W0100 Lbs. (kg) 24-/4 3M'(20) 25/16' (58.7) 24-1 1' (25) 2/a (66.7) 15/31' (21.8) 1/16" (33.3) 13/m" (30.2) 13/16" (30.2) 51/2 )1.61) 6 (1.83) 5/i'(7.9) 5/16" (7.9) 9 (4__J 9 (4.1) [ 24-1'I4 11/4 (32) 3" (16.2) 11/2 (38.1) 1/16" (30.2) 61/2 (1.98) /16'(7.9) 11 (5.0)__J 24-11/2 11/2" (40) 31/4 (82.5) 1/8 (42.3) 1/16" (30.2) 7 (2.13) /16" (7.9) 12 (5.4) [24-2 2" (50) 311/16° (93.7) 121/32' (43.6) 1/16" (30.2) 8 (2.44) /16' (7.9) 15 (6.8) 1 Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4' (20mm) thru 2' (40mm) pipe. I 1 ". - 1l,IE0, Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUl). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4' (20mm) thru 2' (40mm). Patent #5,344,108 ®Tacar USTEB' All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 70 Fire Protection Solutions BLinè byFr.N . Seismic Bracing Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 1' (25mm) thru 8' (200mm) lPS. Pipe size used for bracing: 1" (25mm) and 1/4" (32mm) Schedule 40 lPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1. (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 71. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1' (25mm) or 1114" (32mm)), and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. Pipe Size in. (mm) Part Number & Approx. W0100 1" (24mm) Brace Pipe 11/4" (32mm) Brace Pipe Lbs. (kg) Lbs. (kg) Design Load - Lbs. For Brace Pipe Size 1" / 11/4 Sch. 7 Sch. 10 Sch. 40 1"/11/C 1"! 11I4" 1" I 1/4° L_rj25) 1001-1 X 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) --I-- 1000 /1000 1000/1000 11/4" (32) 1001-11/4 X 100.0 (45.3) 1001-1'/4 X 11/4 114.0 (51.7) -- / -- 1000/1000 1000 /1000 [ii' (40) 1001-1'I2 X 100.0 (45.3) 1001-11/2 X 11/4 115.0 (52.1) --I-- 1500/1500 1500/1500 (50) 1001-2 X 108.0 (49.0) 1001-2X 11I4 121.0 (54.8) --/ -- 2015/2015 2015/2015 (65) 1001-21/2 X 138.6 (62.8) 1001-21I2 X 11/4 160.4 (12.7) 1600/1600 2015/2765 2017F/ 2-76-5 71 (80) 1001-3X1 147.2 (66.7) 1001-3X1'/4 168.1 (76,5) 1600/1600 2015/2165 2015/2765 (100) 1001-4X1 160.9 (73.0) 1001-4X11/4 182.4 (82.7) 1600/1600 2015/2165 2015/2765 6" (150) 1001-6 X 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 1600 /1600 2015/2165 2015/2765 [8 (200) 1 1001-8 X 217.4 (98.6) 1 1001-8 X 11/4 238.8 (108.3) 1 1600/1600 2015/2765 2015/2165 1 AppovID Seismic Bracing Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 10 (25mm) thru 8" (200mm) IPS. Pipe size used for bracing: 1' (25mm) and 11/40 (32mm) Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 70. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1" (25mm) or 11/4' (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the FM Approval requires that Fig. 1001 must be used only with other TOLCO bracing products. Designed to meet or exceed requirements of FM DS 2-8. Pipe Size in. (mm) Part Number & Approx. Wt./100 1" (24mm) Brace Pipe 11/4" (32mm) Brace Pipe Lbs. (kg) Lbs. (kg) Design Load - For Sch. 7, Sch. 10, & Sch. 40 Pipe Allowable Horizontal Capacity (lbf) Per Installation 1.2.3 30°-440 450-59° 60°-740 750 900 Lbs. (kN) Lbs. NN) Lbs. (kN) Lbs. (kN) (25) 1001-1 X 100.0 (45.3) 1001-1 X 11I4 118.0 (53.5) 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25)j 1'/4"(32) 1001-1'/4X1 100.0 (45.3) 1001-1'/4X1'/4 114.0 (51.1) 1230 (5.41) 1740 (7.14) 2140 (9.52) 2380 (10.58) 1001-11/2 X 100.0 (45.3) 1001-11I2 X 11I4 115.0 (52.1) 1230 (5.41) 1740 (1.74) 2140 (9.52) 2380 (10.58)1 (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) 1230 (5.41) 1740 (1.14) 2140 (9.52) 2380 (10.58) [21/2"(65) 1001-21/2 X1 138.6 (62.8) 1001-2'/2X1'/4 160.4 (72.1) 800 (3.56) 1130 (5.02) 1380 (6.14) 1540 (6.85)1 (80) 1001-3 X 1 141.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (1.29) (100) 1001-4 X 1 160.9 (13.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (1.29) I 6" (150) 1001-6 X 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 217.4 (98.6) 1001.8 X 11/4 238.8 (108.3) 1 510 (2.21) 730 (3.25) 890 (3.96) 990 (4.40) 1 1 FM Approved when used with 1 or 1/4 inch NPS Schedule 40 GB/T 3091,EN 10255H, or AS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/I 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/I 3092,EN 10255M and II. or JlS G3454, FM Approved Thinwall. or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. • - Fire Protection Solutions 71 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 66 Fire Protection Solutions BLiAë byE.N Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" Size Range: One size fits bracing pipe 1" (25mm) thru 2" (50mm), B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31.7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 67. Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000, 2002, 4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. K Set Bait Included Mounting Hardware Is Not Included Pat. #6,273,372, Pat. #6,517,030, Pat, #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Fig. Part Mtg. Hdw. Mounting Hole Max. Design Approx. Number Size A B D Load (cULus) W000 in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) I 980-/8/8"(9.5) 51/4" (133.3) 1118" (47.6) /32" (10.3) 2015 (8.96)149 (61.6)J 980-1/2 * 1/2" (12.7) 51/4" (133.3) 1I8" (47.6) 11/32" (13.5) 2015 (8.96) 148 (67.1) [ 980i/e /8" (15.9) 51/4" (133.3) 1/8" (47.6) 11/16" (11.5) 2015 (8.96) 141 (66.1)_lI 980-I4 3/4" (19.0) 51/4" (133.3) 1I6" (47.6) /16" (20.5) 2015 (8.96) 146 (66.2) * Standard size. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. 1?? K Set Bolt Included Mounting Hardware Is Not Included Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" ®TOLcD- Size Range: One size fits bracing pipe 1' (25mm) thru 2' (50mm), B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4' (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the 'bracing pipe' and TOLCO 'braced pipe' attachment, Fig. 1000, 1001, 4L; or other TOLCO approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the 'bracing pipe. Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 66. Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001, 4L or other TOLCO approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Designed to meet or exceed requirements of FM DS 2-8. Fig. Part Mtg. Hdw. Number Size A B in. (mm) in. (mm) in. (mm) ,9O18 3/8 j.5)_51I4"j133.3) _._j?I8'j41.6 980.1/2* 1/2" (12.7) 51/4" (133.3) 11/8" (41.6) 980-/8/8" (15.9) 51/4" (1333) 1I8" (41.6) 980-/4 3/4" (19.0) 51/4" (133.3) 11/8" (41.6) Mounting Hole D 300 .440 in. (mm) I IbsI(kN) /32" (13.5) 1 1320 11/16" (11.5) (5.87) 13/16" (20.5) Max. Design Load** (FM) Approx. 450 .590 60°-14° 750 .900 W000 lbsl(kN) Ibs./(kN) Ibs./(kN) I lbs. (kg) 1970 2310 2550 148 (61.1) (8.76) (10.21) (11.34) 147 (66.7) 146 (66.2) * Standard size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. FM Approved design loads are based on ASD design method. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty. Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 67 B4Jflë by1 Et.N I. nnuai UflU flex i'iuis IflCIUUUU All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 49 BLiflé Seismic Bracing• Fig. 4A - Pipe Clamp for Sway Bracing Size Range: 4' (100mm) thru 8' (200mm) pipe. For sizes smaller than 4' (100mm) use B3140. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 4" (100mm) thru 8' (200mm). Installation Instructions: Fig. 4A is the "braced pipe" attachment component of a longitudinal, lateral or riser brace assembly. It is intended to be combine with the 'bracing pipe' and TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 4A over the pipe to be braced. Attach TOLCO transitional fitting, either Fig. 980, 910 or 909, to the clamp ears. Tighten bolts and nuts; torque requirement is a minimum of 50 ft/lbs. (68Nm). Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish Note: Please refer to Fig. 4L for longitudinal brace applications for 2" (50mm) - 8" (200mm) pipe sizes. Fig. 4A -Longitudinal - Brace Pipe Max. Horizontal Approx. Pad Size A B C D Bolt Design Load Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) Size lbs. (kN) lbs. (kg) I 4A-4 4" (100) 81/2' (215.9) /16' (14.3) 3/8' (85.7) 311/16" (93.1) 1/2"_13 - 1600 (1.11) 221 (100.2) 1 4A-5 (125) 93/4 (247.6) /16" (14.3) 3/8 (98.4) 4/8" (111.1) h/2"_13 1600 (1.11) 253 (114.7) [ 4A-6 (150) 111/1'(292.1) 5/g" (15.9) 5' (127.0) 51/g" (130.2) 1/2"_13 2015 (8.96) 513 (232.7) 1 4A-8 8" (200) 131/4" (336.5) 3/4" (19.0) 611/16 (169.9) 61/8' (155.6) 1/2"_13 2015 (8.96) 601 (272.6) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. INSTALLATION STEPS -WIMM INTO WOOD & STEEL: IINST 1M10N STEPS - Itó);1M.]1fA1,INTO WOOD & STEEL] insert the appropriate nut driver into a H" or 112"portable drill. Insert the SAMMYSa into the #14 (black) nut driver (p/n 8113910). Diiil should be in a vertical position a Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4", 3/8", 1/2"ormet,ic all thread rod, bolt stock (The 112"requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque 1020 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. a When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or boll stock Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. E-*T uhIII L!STALLATION STEPS -WINEM INTO CONCRETE: Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). 3 Insert the CST screw into the nut driver. Place tip of screw into the pm-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or boll stock (#14SWred nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. [INSTALLATION STEPS - f.Mt1b INTO CONCRETE: 1 Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2"with a hammer/ rotary hammer drill set on impact mode. Alter pro-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. a Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill The SWC screw is ready to receive 1/4", .3/8" or metric all thread rod or bolt stock Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. 111111 ltililiIlii-; 11111 10- SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Not less than 2' nominal Wdth vs FOR WOOD No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. 0wtha rides demonst'ella,,i\ www.ifwbulldex.comj a,. #14 Black Nut Driver Part # 8113910 1 #14 SW Red Nut Driver Part #8114910 114" 8002957 GST 100 1/4 x V 210 (7116' OSB) 670 (314' Ply) 25 125 1/4' 8003957 GST 200 1/4x2' 1760 (Fir) 25 125 1 3/8" 8007957 GST 10 210 (7/16'OSB) 670 (3(4' Ply) 300 25 125 8008957 GST 20 1/402' 1760 (Fir) 850 1475 25 125 J 3/8' 8068925 GST 2D-SS 114x2' 1760 (Fir) 850 25 125 [I 3/8' 8009925 GST 25-380 3/8x2-1/2' 2113 (Fir) 1500 25 125_j <&> 3/8' 8010957 GST 30 1/403' 2060 (Fir) 1500 1475 25 125 3)8" 8069925 GST 30-SS 1/403" 2060 (Fir) 25 125 j - 1/2' 8013925 GST2 1/4x2' 1760 (Fir) 25 125 1/2' 8015925 GST3 1/4x3' 2275 (Fir) 25 125 1 =USA SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ~M] M11, fit N i Not less than? nominal width (1.112') up to 3-112' pipe; not less than 3'(2-1/2') nominal width 4' & 5' pipe 7 J Minimum 2-l!2 from 5om for branch lines. Minimum 3 from bot- tom for mainlines. Exception: This requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. 'Manufactured in the U.S.A. ,oiooirw-tmi;\ www.itwbuildex.com) - 1I4' 8019957 318' 8020957 318' 8021957 318' 8073925 . 3/8" 8022925 #14SWRed 3W 8023925 Nut Driver Part #8114910 May require pre.drtnng; consue joist manufactwer. SWG 200 1I4x2' 1725 (Fir) 25 125 SWG 10 SING 20 1/4x1' 114x2' 622 (Fir) 1725 (Fir) 300 1050 25 25 125 125 WÔi 1/4x2' 1725 (Fir) 850 25 125 SWG 25-380 3I8x 2-1/2' 2249 (Fir) 1500 25 125 SWG 30 1I4x3' 1884 (Fir) 25 125 System No. F—C-2160 F Rating - 1 and 2 Hr T Rating - 1 and 2 Hr SECTION A—A I. floor—Ceiling Assembly The 1 and 2 hr fire—rated solid or trussed lumber joist floor—ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor—Ceiling Designs in the UL Fire Resistance Directory. The general construction features of the floor—ceiling assembly are summarized below: Flooring System Lumber or plywood subfloor with finish floor of lumber, plywood or floor Topping Mixture' as specified in the individual floor—Ceiling Design. Max diameter of opening shall be 4 in. Wood Joists* Nom 10 in. deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or• Structural Wood Members' with bridging as required and with ends firestopped. Furring Channels (Not Shown) Resilient galv steel furring installed perpendicular to wood joists between first and second layers of wallboard (Item 1D). Furring channels spaced max 24 in. Gypsum Board* Nom 4 ft wide by 5/8 in. thick as specified in the individual floor—Ceiling Design. First layer of wallboard nailed to wood joists. Second layer of wallboard screw—attached to furring channels. Max diam of ceiling opening is 4 in. 2. Through Penetrants One nonmetallic pipe or conduit to be installed concentrically or eccentrically within the firestop system. Annular space between pipe or conduit and edge of opening to be mm 1/2 in. and max 1-1/8 in. Pipe or conduit to be rigidly supported on both sides of floor—ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: Polyvinyl Chloride (PVC) Pipe Nom 2 in. diam (or smaller) Schedule 40 solid or cellular care PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. Chlorinated Polyvinyl Chloride (CPVC) Pipe Nom 2 in. diam (or smaller) SDR13.5 CPVC pipe for use in closed (process or supply) piping systems. 3. Fill, Void or Cavity Materials'—Sealant Fill Material forced into annular space to fill space to max extent possible. Sealant shall be installed flush with both surfaces of floor—ceiling assembly. HILI1 CONSTRUCTION CHEMICALS, DIV OF H1L11 INC - FS—ONE Sealant. 'Bearing the UL Classification Mark LEIIIIP__!=i_ij_JIII Reproduced by HILfl, Inc. Courtesy of () Underwriters Laboratories, Inc. FIRESTOP SYSTEMS December 17, 1999 (C C.' - - - Fire Protection by Computer Design Cosco Fire Protection, Inc. 4990 GREENCRAIG LANE San Diego, CA 92123 858-444-2000 Job Name : Converse @ Carlsbad Premium Outlet Center Building : FP2 Location : CARLSBAD, CA 92008 System : CALC AREA I Contract : 10.CD_5630 Data File : 10.CD_5630 CONVERSE UPGRADE.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 1 Date 9/8/2015 Cosco Fire Protection, Inc. Converse @ Carlsbad Premium Outlet Center HYDRAULIC CALCULATIONS for Project name: CONVERSE CARLSBAD OUTLET T.I. Location: CARLSBAD, CA 92008 Drawing no: FP2 Date: 9/8/2015 Design Remote area number: CALC AREA 1 Remote area location: LEVEL 1 Occuoancv classification: EXTRA HAZARD GROUP I Density: .45-GpmlSqFt Area of application: 3085 - SqFt Coverage per sprinkler: 100 - SqFt Type of sprinklers calculated: QR UPRIGHTS No. of sprinklers calculated: 33 In-rack demand: N/A - GPM Hose streams: 500 - GPM Total water required (including hose streams): 2018.66 - GPM Type of system: WET PIPE SYSTEM Volume of dry or preaction system: N/A - Gal Water supply information Date: 07-15-15 Location: 5260 PASEO DEL NORTE, CARLSBAD, CA 92008 Source: CARLSBAD FIRE DEPARTMENT Name of contractor: COSCO Address: 4990 GREENCRAIG LANE Phone number: 858-444-2000 Name of designer: FELIPE Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) © 39.616 - Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 City Water Supply: Cl - Static Pressure : 72.9 C2 - Residual Pressure: 12.9 C2 - Residual Flow : 3250 Demand: Dl - Elevation : 5.143 D2 - System Flow :1518.66 D2 - System Pressure : 39.616 Hose ( Demand) : 500 D3 - System Demand :2018.66 Safety Margin : 8.423 Water Supply - ye C Cosco Fire Protection, Inc. Page 2 Converse © Carlsbad Premium Outlet Center Date 9/8/2015 150 140 130 p 120 R 110 E 100 S 90 S 80 u 70 R 60 E 50 D2 40 30 20 10 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used - imary Cosco Fire Protection, Inc. Page 3 Converse © Carlsbad Premium Outlet Center Date 9/8/2015 Fitting Legend Abbrev. Name 1/2 % 1 1'/4 1Y2 2 2'/2 3 3'/2 4 5 6 8 10 12 14 16 18 20 24 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90' Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 0 0 0 0 0 0 0 X 90'Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Cosco Fire Protection, Inc. Page 4 Converse © Carlsbad Premium Outlet Center Date 9/8/2015 No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. TOR 13.083 28.7 na Xl 13.083 27.06 na X2 14.0 21.37 na X4 14.0 19.64 na X5 14.0 19.23 na X6 14.0 18.95 na X7 14.0 18.7 na X8 14.0 18.51 na X9 14.0 18.37 na XIO 14.0 18.28 na Xli 14.0 18.23 na X12 14.0 18.2 na XN3 14.875 19.95 na XN4 14.875 18.32 na XN5 14.875 17.93 na XN6 14.875 17.67 na XN7 14.875 17.42 na XN8 14.875 17.24 na XN9 14.875 17.11 na XNIO 14.875 17.02 na XN11 14.875 16.97 na XNI2 14.875 16.95 na XN13 14.875 16.94 na 1 14.875 11.2 19.02 na 48.84 0.45 100 7.0 2 14.875 11.2 19.09 na 48.94 0.45 100 7.0 3 14.875 11.2 19.37 na 49.29 0.45 100 7.0 4 14.875 11.2 17.46 na 46.8 0.45 100 7.0 14.875 11.2 17.53 na 46.9 0.45 100 7.0 14.875 11.2 17.79 na 47.24 0.45 100 7.0 14.875 11.2 17.09 na 46.3 0.45 100 7.0 8 14.875 11.2 17.16 na 46.39 0.45 100 7.0 9 14.875 11.2 17.41 na 46.73 0.45 100 7.0 10 14.875 11.2 16.84 na 45.96 0.45 100 7.0 11 - 14.875 11.2 16.9 na 46.05 0.45 100 7.0 12 14.875 11.2 17.15 na 46.38 0.45 100 7.0 13 14.875 11.2 16.6 na 45.64 0.45 100 7.0 14 14.875 11.2 16.67 na 45.73 0.45 100 7.0 15 14.875 11.2 16.91 na 46.06 0.45 100 7.0 16 14.875 11.2 16.43 na 45.39 0.45 100 7.0 17 14.875 11.2 16.49 na 45.49 0.45 100 7.0 18 14.875 11.2 16.74 na 45.82 0.45 100 7.0 19 14.875 11.2 16.3 na 45.22 0.45 100 7.0 20 14.875 11.2 16.37 na 45.31 0.45 100 7.0 21 14.875 11.2 16.61 na 45.64 0.45 100 7.0 22 14.875 11.2 16.22 na 45.11 0.45 100 7.0 23 14.875 11.2 16.29 na 45.2 0.45 100 7.0 24 14.875 11.2 16.53 na 45.53 0.45 100 7.0 25 14.875 11.2 16.17 na 45.04 0.45 100 7.0 26 14.875 11.2 16.24 na 45.13 0.45 100 7.0 27 14.875 11.2 16.48 na 45.46 0.45 100 7.0 28 14.875 11.2 16.15 na 45.01 0.45 100 7.0 29 14.875 11.2 16.22 na 45.1 0.45 100 7.0 30 14.875 11.2 16.45 na 45.43 0.45 100 7.0 31 14.875 11.2 16.14 na 45.0 0.45 100 7.0 32 14.875 11.2 16.21 na 45.09 0.45 100 7.0 33 14.875 11.2 16.45 na 45.42 0.45 100 7.0 BOR 0.5 34.95 na UGI -3.0 37.64 na BF1 -3.0 39.31 na -3.0 41.45 na ST 3.0 39.62 na 500.0 The maximum velocity is 16.35 and it occurs in the pipe between nodes BOR and UGI Computer Programs by Hydratec Inc. Route 111 Windham.N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Cosco Fire Protection, Inc. Page 5 Converse @ Carlsbad Premium Outlet Center Date 9/8/2015 yd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *ADDED RIGHT MAIN TOR -1518.66 6.357 V 12.573 14.500 28.700 to 120.0 0.0 12.573 0.0 Xl -1518.66 -0.0606 0.0 27.073 -1.641 Vel = 15.35 Xl 0.0 6.357 X 31.433 43.250 27.059 to 120.0 V 12.573 44.006 -0.397 X2 -1518.66 -0.0606 0.0 87.256 -5.288 Vel = 15.35 X2 1371.58 6.357 X 31.433 6.917 21.374 to 120.0 0.0 31.433 6.063 X3 -147.08 -0.0008 0.0 38.350 -0.031 Vel = 1.49 0.0 -147.08 27.406 K Factor = -28.10 X2 -1371.59 6.357 X 31.433 3.083 21.374 to 120.0 0.0 31.433 0.0 X4 -1371.59 -0.0502 0.0 34.516 -1.733 Vel = 13.86 X4 140.95 6.357 0.0 10.000 19.641 to 120.0 0.0 0.0 0.0 X5 -1230.64 -0.0411 0.0 10.000 -0.411 Vel = 12.44 X5 139.42 6.357 0.0 8.417 19.230 120.0 0.0 0.0 0.0 :6 -1091.22 -0.0328 0.0 8.417 -0.276 Vel = 11.03 X6 138.39 6.357 0.0 10.000 18.954 to 120.0 0.0 0.0 0.0 X7 -952.83 -0.0256 0.0 10.000 -0.256 Vel = 9.63 X7 137.43 6.357 0.0 10.000 18.698 to 120.0 0.0 0.0 0.0 X8 -815.4 -0.0192 0.0 10.000 -0.192 Vel = 8.24 X8 136.70 6.357 0.0 10.000 18.506 to 120.0 0.0 0.0 0.0 X9 -678.7 -0.0137 0.0 10.000 -0.137 Vel = 6.86 X9 136.18 6.357 0.0 10.000 18.369 to 120.0 0.0 0.0 0.0 XIO -542.52 -0.0090 0.0 10.000 -0.090 Vel = 5.48 XIO 135.84 6.357 0.0 10.000 18.279 to 120.0 0.0 0.0 0.0 Xli -406.68 -0.0053 0.0 10.000 -0.053 Vel = 4.11 Xli 135.63 6.357 0.0 10.000 18.226 to 120.0 0.0 0.0 0.0 X12 -271.05 -0.0025 0.0 10.000 -0.025 Vel = 2.74 X12 135.54 6.357 0.0 10.000 18.201 to 120.0 0.0 0.0 6.063 X13 -135.51 -0.0006 0.0 10.000 -0.006 Vel = 1.37 0.0 -135.51 24.258 K Factor = -27.51 ADDED RIGHT NIPPLES XN3 147.08 2.635 1 16.474 0.792 19.948 to 120.0 0.0 16.474 6.442 X3 147.08 0.0588 0.0 17.266 1.016 Vel = 8.65 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc. Page 6 Converse @ Carlsbad Premium Outlet Center Date 9/8/2015 I. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 147.08 27.406 KFactor= 28.10 XN4 140.94 2.635 T 16.474 0.792 18.324 to 120.0 0.0 16.474 0.379 X4 140.94 0.0543 0.0 17.266 0.938 Vel = 8.29 0.0 140.94 19.641 K Factor= 31.80 XN5 139.42 2.635 T 16.474 0.792 17.932 to 120.0 0.0 16.474 0.379 X5 139.42 0.0532 0.0 17.266 0.919 Vel = 8.20 0.0 139.42 19.230 K Factor = 31.79 XN6 138.39 2.635 T 16.474 0.792 17.668 to 120.0 0.0 16.474 0.379 X6 138.39 0.0525 0.0 17.266 0.907 Vel = 8.14 0.0 138.39 18.954 K Factor= 31.79 XN7 137.43 2.635 T 16.474 0.792 17.423 120.0 0.0 16.474 0.379 137.43 0.0519 0.0 17.266 0.896 Vel = 8.09 0.0 137.43 18.698 K Factor= 31.78 XN8 136.70 2.635 T 16.474 0.792 17.240 to 120.0 0.0 16.474 0.379 X8 136.7 0.0514 0.0 17.266 0.887 Vel = 8.04 0.0 136.70 18.506 K Factor= 31.78 XN9 136.18 2.635 T 16.474 0.792 17.110 to 120.0 0.0 16.474 0.379 X9 136.18 0.0510 0.0 17.266 0.880 Vel = 8.01 0.0 136.18 18.369 KFactor= 31.77 XN10 135.84 2.635 T 16.474 0.792 17.024 to 120.0 0.0 16.474 0.379 XIO 135.84 0.0507 0.0 17.266 0.876 Vel = 7.99 0.0 135.84 18.279 K Factor= 31.77 XNII 135.63 2.635 T 16.474 0.792 16.973 to 120.0 0.0 16.474 0.379 XII 135.63 0.0506 0.0 17.266 0.874 Vel = 7.98 0.0 135.63 18.226 K Factor= 31.77 XN12 135.54 2.635 T 16.474 0.792 16.949 120.0 0.0 16.474 0.379 X12 135.54 0.0506 0.0 17.266 0.873 Vel = 7.97 0.0 135.54 18.201 K Factor= 31.77 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc. Page 7 Converse © Carlsbad Premium Outlet Center Date 9/8/2015 'd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn XN13 135.51 2.635 T 16.474 0.792 16.943 to 120.0 0.0 16.474 6.442 X13 135.51 0.0506 0.0 17.266 0.873 Vel = 7.97 0.0 135.51 24.258 K Factor= 27.51 *LlNE1 1 48.84 2.635 0.0 10.000 19.018 K Factor= 11.20 to 120.0 0.0 0.0 0.0 2 48.84 0.0077 0.0 10.000 0.077 Vel = 2.87 2 48.94 2.635 0.0 10.000 19.095 K Factor= 11.20 to 120.0 0.0 0.0 0.0 3 97.78 0.0276 0.0 10.000 0.276 Vel = 5.75 3 49.30 2.635 V 5.903 3.917 19.371 K Factor = 11.20 to 120.0 0.0 5.903 0.0 XN3 147.08 0.0588 0.0 9.820 0.577 Vel = 8.65 0.0 147.08 19.948 K Factor 32.93 *LINE 2 46.80 2.635 0.0 10.000 17.464 K Factor = 11.20 120.0 0.0 0.0 0.0 5 46.8 0.0071 0.0 10.000 0.071 Vel = 2.75 5 46.90 2.635 0.0 10.000 17.535 K Factor= 11.20 to 120.0 0.0 0.0 0.0 6 93.7 0.0255 0.0 10.000 0.255 Vel = 5.51 6 47.24 2.635 V 5.903 3.917 17.790 K Factor = 11.20 to 120.0 0.0 5.903 0.0 XN4 140.94 0.0544 0.0 9.820 0.534 Vel = 8.29 0.0 140.94 18.324 K Factor = 32.92 *LlNE3 7 46.30 2.635 0.0 10.000 17.089 K Factor= 11.20 to 120.0 0.0 0.0 0.0 8 46.3 0.0069 0.0 10.000 0.069 Vel = 2.72 8 46.39 2.635 0.0 10.000 17.158 K Factor= 11.20 to 120.0 0.0 0.0 0.0 9 92.69 0.0251 0.0 10.000 0.251 Vel = 5.45 9 46.73 2.635 V 5.903 3.917 17.409 K Factor = 11.20 to 120.0 0.0 5.903 0.0 XN5 139.42 0.0533 0.0 9.820 0.523 Vel = 8.20 0.0 139.42 17.932 K Factor= 32.92 *LlNE4 45.96 2.635 0.0 10.000 16.836 K Factor = 11.20 120.0 0.0 0.0 0.0 11 45.96 0.0069 0.0 10.000 0.069 Vel = 2.70 11 46.04 2.635 0.0 10.000 16.905 K Factor = 11.20 to 120.0 0.0 0.0 0.0 12 92.0 0.0247 0.0 10.000 0.247 Vel = 5.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc. Page 8 Converse @ Carlsbad Premium Outlet Center Date 9/8/2015 yd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 12 46.39 2.635 V 5.903 3.917 17.152 K Factor= 11.20 to 120.0 0.0 5.903 0.0 XN6 138.39 0.0525 0.0 9.820 0.516 Vel = 8.14 0.0 138.39 17.668 K Factor= 32.92 *L1NE5 13 45.64 2.635 0.0 10.000 16.603 K Factor = 11.20 to 120.0 0.0 0.0 0.0 14 45.64 0.0067 0.0 10.000 0.067 Vel = 2.69 14 45.72 2.635 0.0 10.000 16.670 K Factor = 11.20 to 120.0 0.0 0.0 0.0 15 91.36 0.0244 0.0 10.000 0.244 Vel = 5.38 15 46.07 2.635 V 5.903 3.917 16.914 K Factor= 11.20 to 120.0 0.0 5.903 0.0 XN7 137.43 0.0518 0.0 9.820 0.509 Vel = 8.09 0.0 137.43 17.423 K Factor= 32.92 *L1NE6 45.39 2.635 0.0 10.000 16.428 K Factor = 11.20 120.0 0.0 0.0 0.0 17 45.39 0.0066 0.0 10.000 0.066 Vel = 2.67 17 45.49 2.635 0.0 10.000 16.494 K Factor= 11.20 to 120.0 0.0 0.0 0.0 18 90.88 0.0242 0.0 10.000 0.242 Vel = 5.35 18 45.82 2.635 V 5.903 3.917 16.736 K Factor = 11.20 to 120.0 0.0 5.903 0.0 XN8 136.7 0.0513 0.0 9.820 0.504 Vel = 8.04 0.0 136.70 17.240 K Factor= 32.92 *L1NE7 19 45.22 2.635 0.0 10.000 16.303 K Factor = 11.20 to 120.0 0.0 0.0 0.0 20 45.22 0.0066 0.0 10.000 0.066 Vel = 2.66 20 45.32 2.635 0.0 10.000 16.369 K Factor 11.20 to 120.0 0.0 0.0 0.0 21 90.54 0.0240 0.0 10.000 0.240 Vel = 5.33 21 45.64 2.635 V 5.903 3.917 16.609 K Factor = 11.20 to 120.0 0.0 5.903 0.0 XN9 136.18 0.0510 0.0 9.820 0.501 Vel = 8.01 0.0 136.18 17.110 K Factor = 32.92 *LINE8 12 45.11 2.635 0.0 10.000 16.221 K Factor= 11.20 120.0 0.0 0.0 0.0 23 45.11 0.0066 0.0 10.000 0.066 Vel= 2.65 23 45.20 2.635 0.0 10.000 16.287 K Factor = 11.20 to 120.0 0.0 0.0 0.0 24 90.31 0.0238 0.0 10.000 0.238 Vel = 5.31 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc. Page 9 Converse @ Carlsbad Premium Outlet Center Date 918/2015 lyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 24 45.53 2.635 V 5.903 3.917 16.525 K Factor= 11.20 to 120.0 0.0 5.903 0.0 XNIO 135.84 0.0508 0.0 9.820 0.499 Vel = 7.99 0.0 135.84 17.024 K Factor= 32.92 *LlNE9 25 45.04 2.635 0.0 10.000 16.172 K Factor= 11.20 to 120.0 0.0 0.0 0.0 26 45.04 0.0066 0.0 10.000 0.066 Vel = 2.65 26 45.13 2.635 0.0 10.000 16.238 K Factor = 11.20 to 120.0 0.0 0.0 0.0 27 90.17 0.0238 0.0 10.000 0.238 Vel = 5.31 27 45.46 2.635 V 5.903 3.917 16.476 K Factor = 11.20 to 120.0 0.0 5.903 0.0 XNII 135.63 0.0506 0.0 9.820 0.497 Vel = 7.98 0.0 135.63 16.973 K Factor= 32.92 *LlNE1 0 78 45.01 2.635 0.0 10.000 16.150 K Factor= 11.20 120.0 0.0 0.0 0.0 45.01 0.0065 0.0 10.000 0.065 Vel = 2.65 29 45.10 2.635 0.0 10.000 16.215 K Factor = 11.20 to 120.0 0.0 0.0 0.0 30 90.11 0.0238 0.0 10.000 0.238 Vel = 5.30 30 45.43 2.635 V 5.903 3.917 16.453 K Factor = 11.20 to 120.0 0.0 5.903 0.0 XN12 135.54 0.0505 0.0 9.820 0.496 Vel = 7.97 0.0 135.54 16.949 K Factor= 32.92 *LlNE1 I 31 45.00 2.635 0.0 10.000 16.143 K Factor = 11.20 to 120.0 0.0 0.0 0.0 32 45.0 0.0066 0.0 10.000 0.066 Vel = 2.65 32 45.09 2.635 0.0 10.000 16.209 K Factor = 11.20 to 120.0 0.0 0.0 0.0 33 90.09 0.0237 0.0 10.000 0.237 Vel = 5.30 33 45.42 2.635 V 5.903 3.917 16.446 K Factor= 11.20 to 120.0 0.0 5.903 0.0 XN13 135.51 0.0506 0.0 9.820 0.497 Vel = 7.97 0.0 135.51 16.943 K Factor = 32.92 *RISER 'OR 1518.66 6.357 0.0 13.166 28.700 120.0 0.0 0.0 5.450 c3OR 1518.66 0.0606 0.0 13.166 0.798 Vel = 15.35 0.0 1518.66 34.948 K Factor = 256.89 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Cosco Fire Protection, Inc. Page 10 Converse @ Carlsbad Premium Outlet Center Date 9/8/2015 lyd. Qa Dia. Fitting Pipe Pt Pt ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *UG BOR 1518.66 6.16 L 12.911 9.166 34.948 to 140.0 0.0 12.911 1.516 UGI 1518.66 0.0531 0.0 22.077 1.172 Vel = 16.35 UG1 0.0 7.68 2L 32.58 66.958 37:636 to 150.0 G 5.012 37.592 0.0 BFI 1518.66 0.0160 0.0 104.550 1.670 Vel = 10.52 BF1 0.0 8.27 3L 61.681 15.833 39.306 to 140.0 EqI 12.652 74.333 1.000 * * Fixed Loss = 1 BF2 1518.66 0.0127 0.0 90.166 1.141 Vel = 9.07 BF2 0.0 7.68 T 43.857 4.166 41.447 to 150.0 0.0 43.857 -2.599 TEST 1518:66 0.0160 0.0 48.023 0.768 Vel = 10.52 500.00 Qa = 500.00 2018.66 39.616 K Factor = 320.72 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087