HomeMy WebLinkAbout2856 WHIPTAIL LOOP; ; FPC2019-0229; Permitrbtyof PERMIT REPORT Carlsbad Print Date: 02/29/2024 Permit No: FPC2019-0229 Job Address: 2856 WHIPTAIL LOOP, CARLSBAD, CA 92010-6708 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel U: 2091201400 Track U: Applied: 09/30/2019 Valuation: $915,297.00 Lot U: Issued: 10/15/2019 Occupancy Group: Project #: Finaled Close Out: 01/09/2020 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Maldonado, Adalmira Plan Check #: Project Title: Description: CAMSTON WRATHER -ADD TO EX. SPRINKLER MONITORING SYSTEM (ADD POC TO NEW HVAC DUCTS (12), RELOCATE ALARIV KEYPAD ANNUNCIATOR, PULL STATION, & HORN/STROBE TO LOBBY MAIN ENTRANCE) Applicant: FPContractor: JMG SECURITY SYSTEMS JMG SECURITY SYSTEMS TREVOR ASHFORD 17150 NEWHOPE ST, U 109 17150 NEWHOPE ST, U 109 FOUNTAIN VALLEY, CA 92708-4273 FOUNTAIN VALLEY, CA 92708-4250 (714) 545-8862 (714) 943-6156 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Ai 'H IGHLIGHTED SET UL & FM Certificates of Compliance Cut Sheets and CSFM listings CAMSTON WRATHER 2856 Whiptail Loop, Carlsbad, CA 92010 Installation Company: M SYSTEMS G SECURITY Our service is your security. 17150 Newhope Street Fountain Valley, CA 92708 (714) 545-8882 FPC20I9-0229 2856 WHIPTAIL LOOP AMSTON WRATHER - ADD TO EX. SPRINKLER MONITORING SYSTEM (ADD POC TO NEW HVAC DUCTS (12). RELOCATE ALARM KEYPAD ANNUNCIATOR PULL STATION, & HORN/STROBE TO LOBBY MAIN ENTRANCE) 2091201400 9/30/2019 FPC20I 9-0229 V UL) Applicant ID No: 257057-001 Service Center No: I Expires: 31-MAR-2020 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Comoanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LAKE FOREST, CA Alarm Service Company: (257057-001) Service Center: (257057-001) ADVANCED PROTECTION INDUSTRIES LLC, ADVANCED PROTECTION INDUSTRIES LLC, DBA NATIONAL MONITORING CENTER DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR 25341 COMMERCENTRE DR LAKE FOREST CA 92630 LAKE FOREST CA 92630 The Alarm Service Company Is Listed In the following CertIficate Service Categories: File - Vol No. CCN Listing Cateaory S81264 UUFX [Signal and Fire Alarm Equlpmeñtand Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31-MAR2020"t ULOOK FOR THE UL ALARM SYSTEM CERTIFICATE" Powerful addressable fire system Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Rash Updateable: No more firmware chips to replace Adaptive Technology1M - Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. (çRi5OFCX11550FC SERIES COMMERCIAL FIRE PANELS SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on XR55OFC Up to 142 two-wire smoke detector or fire initiating zones on XR15OFC Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection 1itn7? n12Vfl(i 1d IIiitntit) Up to 506 fulLy-programmable Form C relays Serial 3 Digital Dialer or CID reporting to multiple receivers Eight communication paths between the panel and Central Station Built-in remote or on-site feature upgrade capability 12.000 event buffer Multi-lingual menus available Multiple on-board status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas, with common areas Output Groups: Maximum functionality—Minimum programming XRI50DNFC/XR55ODNFC SYSTEM FEATURES All above listed System Features On-board Ethernet connection for Network MonitoringTM Customizable check-in time and retry time Suitable for multi-site applications where the Internet or LAN/WAN is available XRI50FC & XR550FC The XR1 50DFC and XR550DFC provide basic fire monitoring for any single site application. The XR1 50DNFC and XR550DNFC panels provide all the same basic fire monitoring as the XR1 50DFC and XR550DFC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DAf.I NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a Lock and key. KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. XRI50FC/XR550FC TYPICAL NOTIFICATION/ANNUNCIATION Digital SLC Loop 2 Any expansion device can operate on SLC Loop I or2 12or24VDC I H NAC1 12or24VDC [yncModule Strobe Mini-Ham IJ12 or 24 VD NAC2 12 or 24 VDC Power Supply Sync Module Ham Strobe NAC2 505-12 or other 12/24VDC UL Motor Bell Commercial Fire Approved Digital Power Supplies Annunciator Bus Digital SIC Additional 630F Loop 1 Fire Command Centers 630F Fire Command Center FLEXIBLE COMMUNICATION The XR150DNFC and (XR55ODNFCJ has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger. multi-layered panel communications that ensure a constant Link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path, the 263C or 263H provides the security of a communication link that continues to function, even when Land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. EIGHT COMMUNICATION PATHS Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the Central Station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and email status from the keypad. FIRE ZONE PROGRAMMING Program zones for fire, fire verify fire retard, presignal, cross zoning. or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR1 50FC and XR550FC provide up to 570 zones, programmable for a variety of fire applications. The system provides Class B 12VDC powered zones, two on-board and four on the 715 Module, plus eight panel burglary zones. Up to 60 zones are available on 15 keypad addresses and up to 100 zones are available on each built-in LX_BusTM using Expansion Modules. FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR150FC/ XR550FC system. Up to three Class B modules can be mounted within the FACP. Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature allows a single technician to check the panel response to fire, burglary, panic and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones, find individual zone numbers, check the LX-Bus for Missing, Overlapping and/or Extra zones, and much more, all from any DMP LCD keypad. FLASH UPDATEABLE The XR150FC and XR550FC panels accept software updates from a remote location using Remote LinkTM software. When new XR1 5OFCIXR55OFC feature updates release, perform the flash update remotely. The XR150FC and XR550FC allow theuse.. of two SPDT relay outputs and four open collector outputs. that may be activated by zone or system events, by schedule, through the User Menu or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. MULTI-LINGUAL DISPLAYS For additional flexibility, keypads attached to the XR1 50FC and XR550FC panels can display keypad Status List and User Menu text using multiple languages. The user has the option to select the language to use. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location and other zones can be programmed to display and be monitored at different keypad Locations. 12,000 EVENT MEMORY Allows the user to view the last 10.000 door accesses or 2.000 system events that occurred over the past 45 days. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® WindoWSTM. The XR1 50FC and XR550FC include an interface connection for installers to use to conned a laptop computer. EXPANSION MODULES 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class-B Expansion 714-8 8-zone Class-B Expansion i) 16 -zone CLassB Efpaision) 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion, 4 Form C relays. 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs CELLULAR COMMUNICATORS (cpM lómm.Ur1ö?. 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (Ali require a 381 cable) AUXILIARY MODULES 860 Relay Output Module 865 Style WIX Notification Circuit Module (StyLiW Notifiátiàc) M6dülé1 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module 505-12A 5 Amps @ 12 VDC PULL STATIONS esPuliSfajj!!s SMOKE/HEAT DETECTORS 521 B/B)CF Conventional Smoke, CleanMe 521 LX/LXT Addressable Smoke/Heat, CleanMe ACCESSORIES 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18' Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1 R Network Enabled Receiver Compatabte with Central Station Receivers that accept Standard CID. DD. or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS TwO)1) 1100X Receiver iiray 11 00X High Power Receiver 1I0011 Repeater 1103 Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165H5 Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VDC Battery Models 365.366.368 or 369 Output Rating Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For UL installations, total bell, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: Material Cold-rolled steel (Red) ORDERING INFORMATION XR1 5ODFC-R XR1 50 Fire Control Panel XR1 5ODNFC-R XR1 50 Fire Control Panel with Network XR550DFC-R XR550 Fire Control Panel XR5SODNECR XR550 Fire Control Panel with LISTINGS AND APPROVALS Refer to the XR1 5OFC/XR55OFC Installation Guide U-1297), XR1 5OFC/ XR550FC Programming Guide (LT-1232) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance. 0 01ev Own 01nn awn an 01ev Clan Listed Resistors 1.0k Ohm - DMP Model 311 3.3k Ohm - DMP Model 309 10K Ohm - DMP Model 308 ö Auxiliary Power Total current combined from terminals 7, 11, 25, 27, and LXSOO-1X900 RED .5 Amp Max viater Earth nd 1.5k Bed aitoff time range Is 5 to 99 minutes marditime and.. Zone Expander II Zone Ii Model 714 Expander 1Zone Expande 7mA@12VDC Model 711 (up to 8 zone Models 714-8, 714-16 7mtA @ 12 I Model 712-8 20mAI0l12VDC 19mA@12 I II VDC Use UL Listed Power Supervision Relay rated at 12 VDC. - LA 04" System Components 3.1 Wiring Diagram The diagram shows some of the accessory modules you can connect for use in various applications. A brief description of each module follows in section 3.4. AC Wring must be In conduit and ..— _.. out the left side c( the enclosure. exit right and maintain 1/4' separation I LED anus Culor Cude-Modni 431 Hurv. Wring on terminals 5 through 22 mist I A C R.b5. Activity LED Unk LED o utput MO O,.flselWlit. ®iâi from the AC and battery positive wiring I ugus a Cu., wvnvls,.y Outp ut 2 MC vl.I.t/w%Iw 5SVA 75V A.n,.ra.Ovanra(JI1) PHONE LINE °'" "Y 33 ® u5ut I N!O 0,.ns. ETHERNET outputi SIC YSM output culorCodv utput3 Red 318 )M550FC Series Am 4 5kW Am 5 El 37 Panel LOAD 311 I 'he' bkrk 011153.6 1 0?9 2 16 324 RESEr Start 4 9 H KLX CELL MODULE ________ 313 '5±53.55 BattelyaD ]10 LMPER 38 314 39 315 317 319 L1LI1F NFPA 72 This equipment should be Installed In accordance with Chapter 11 of the National Fire Alarm Code, ANSI/NFPA 72-2002, (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed Information describing proper Installation, operation, testing, maintenance, evacuation planning, and repair service is to be provided with this equipment All circuits are inherent Power Limited except the red battery wire and AC terminal. DMP Transformer 16 VAC 56 VA Class 2 Wire-In. Secondary Power Supply 1.0 Amps Max. charging current Use only 12 VDC rechargeable batteries. DMP Models 364, 365, 366, 368, or 369. Replace batteries every 3 to 5 years. Bell 12 VDC nominal Minimum cutoff time Is 5 minutes. .7 Amp Max Keypads Model 630F Cn.,.n 10-1 . unr (D = supervised Circuit Heat detectors, pull stations, or any other contact devices listed for HIS Protective Signaling can be connected to zones 9 and 10. Zones9 and band Model 715 compatibility Idenhifler: A Maximum operating range: 9.8 VDC to 14.0 VDC. Class B (style A). Zones 9, 10, and all expanded zones are suitable for Class B (as applicable for the Initiating and signaling line circuits per ANSI/UL 864 table 48.2 or 48.3). Installation limits under local Authority Having Jurisdiction (Am). Using verification delays on zones 9 and 10 Is optional. Use the delays marked on the smoke detectors or the smoke detector Installation Wring diagram. Verification Confrol Unit Smoke Detector Zones Delay Model Delay — 13.6 sec. I _sec. Zone Expander Model 715 7mA@ 12 VDC Models 715-8, 715-16 20mA @ 12 VDC CAUTION: DO NOT USE LOOPED WIRE Fli1 1k Own UNDER TERMINALS. BREAK WIRE RUN TO I I PROVIDE SUPERVISION OF CONNECTIONS. WARNING: Incon-ect connections may cause damage to the unit. WARNING THIS UNIT MAY BE PROGRAMMED TO USE AN ALARM VERIFICATION FEATURE THAT RESULTS IN DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DEFECFORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER SMOKE DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING )URISDICTION (All]). Figure 1: XRI 50FC/XR550FC Series Wiring Diagram 3.2 Lightning Protection Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on XR1 50FC/XR550FC Series input and output circuits. Additional surge protection is available by installing the DMP 370 or 370RJ Lightning Suppressors. 3.3 Network Protection The Model 270 Network Transient Suppression Module protects the XRI 50FC/XR550FC panel from surges on the ETHERNET port. XRI50FCIXR550FC Series Installation Guide Digital Monitoring Products 3 -- 6.8 Power Requirements During AC power failure, the XR1 50FC/XR550FC Series panel and all connected auxiliary devices draw their power from the battery. ALL devices must be taken into consideration when calculating the battery standby capacity. The following table Lists the panel power requirements. You must add the additional current draw of keypads, zone - expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours required. - Standby Battery Power Calculations Standby Current Alarm Current 1N6Fc/xR550Fc Series Control Panel Qty I x J74iiA fj 747 Qty 1 x i17riiAJ 217A Relay Outputs 1-2 (ON) Qty ______ 30mA Qty ______ 30mA Switch Grounds 3-6 (ON) Qty _______ 5mA Qty _______ 5mA Active Zones l-8 Qty _____ 1.6mA Qty _____ 2mA* Active Zones 9.10 Qty ______ 4mA Qty ______ 30mA 2-Wire Smoke Detectors Qty ______ 0.1mA Qty ______ 0.1mA Panel Bell Output 1500mA ______mA 893A Dual Phone Line Module Qty x 12mA Qty _______ x 50mA 2630CDMACeLLülCommunicáth7) Qty x (13rnA D Qty ______ x (j3mA 263H HSPA+ Cellular Communicator Qty x 24mA Qty x 28mA 277 Buzzer Module Qty x 5mA Qty x 5mA IlOOX Wireless Receiver Qty x 46mA Qty x 46mA IIOOXH Wireless High Power Receiver Qty x 160mA Qty x 160mA 860 Relay Output Module (one relay active) Qty x 34mA Qty x 34mA All four relays active 138mA 138mA 865 Style Y or Z Notification Module Qty x 26mA Qty x AW ffy*17e ,4'i oeifiM@ffiM 85mA E66 Qty x ____ Qty x (A 867 DC-Bus Style W Notification Module Qty x 30mA Qty x 86mA 869 Dual Style D Initiating Module Qty x 25mA Qty x Command Center) Qty 75mA 630r!16ffiofe-'Fire x Qty x _____ 7060/7160 Thinline/7060A Aqualite Keypad Qty x 72mA Qty x 80mA 7063/7163 Thinline/7063AAqualite Keypad Qty x 85mA Qty x lOOmA 7070/7170 Thinline/7070A Aqualite Keypad Qty x 72mA Qty x 87mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7073/7173 Thinline/7073AAqualite Keypad Qty x 85mA Qty ______ x lOOmA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7872 Graphic Touchscreen Keypad Qty x 145mA Qty ______ x 215mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7873 Graphic Touchscreen Keypad Qty x 143mA Qty x 243mA Active Zones (EOL Installed) 1.6mA Qty x 2mA 734 Wiegand Interface Module Qty x 15mA Qty x 15mA Active Zones (EOL Installed) Qty x 1.6mA Qty x 2mA Annunciator (ON) Qty _______ x 20mA 734N Wiegand Interface Module Qty x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty x 2mA* Annunciator (ON) Qty _______ x 20mA Wiegand Reader Qty x 200mA Qty _______ x 200mA Copy Sub-Totals to next Ipage Sub-Total Standby ______mA Sub-Total Alarm ______mA *Based on 10% of active zones in alarm. Digital Monitoring Products XRI50FC/XR550FC Series Installation Guide 10 Your Source for Cellular Solutions The switch is on to cellular for many reasons. In isolated locations, cellular may be the best primary communications path option. Where Land tines could go down, cellular provides a reliable backup path. In critical installations where you need to eliminate the risk of cut phone or network lines, cellular is the solution. Whatever your need. DMP has the technology to create reliable panel-to-central station digital cellular communications. Direct cellular communication enables a direct path for alarm signals from the panel to the monitoring station Uses digital cellular CDMA or HSPA+ data networks in the US and Canada Transmits email and SMS status messages to multiple recipients XR550 and 263H HSPA+ Shown with )C130 and 263C COMA Shown with 383 383 Rubberduck Antenna. Rubberduck Antenna. (Not to scale) DIGITAL CELLULAR COMMUNICATORS CDMA&HSPA+ f. SYSTEM FEATURES Modular add-on to XI or XR Series Panels Plug-and-play installation and activation of add-on communication modules Power from panel or separate power supply. with Low current draw for tong standby battery life Fully supervised to ensure the health of communication DMP Adaptive lechnologyTM switches communication paths while maintaining supervision if the current path becomes unavailable on the XR SeriesTM panels Direct renortina to any DMP Central Station receiver with no Check signal strength indication at the keypad MyAccessTM Messaging features, including text message alerts from the panel. and ability to send commands to the panel via text messages Supports the DMP App XR500E/XR550E provides privacy for your data with DMP encryption technology XR1 00FC/XR500FC and 463C have FDNY approval for network or cell primary communication PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path, providing installation flexibility and economical options of digital cellular communication. For commercial fire applications, the 263C/263H/463C can be used as a stand- alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Or, use your cellular communicator as a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut or corn promised. The battery backup provides continued communications even when power is lost. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones. Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGYTM If the primary communication path is compromised or becomes unavailable. Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The checkin frequency and programming for a backup path adapt to the checkin programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel's processor over the COMA or HSPA+ wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP Central Station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom Cellular Service from DMP, you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel via an expansion card, the unit is ready to use the SecureCom service. After installing the panel or card, activate the unit via Remote LinkTM. After programming the panel Remote Link recommends the optimum data plan based on the level of security, desired communication path configuration. and specific programming for the account. REMOTE CONTROL VIA MY ACCESSTM: SMS MESSAGING DMP MyAccess lets users send commands via text messages to their panel Residential and smaller commercial users can now remotely control their systems, including the ability to arm /disarm, control outputs, retrieve system status, and perform automation functions. Each command received by the panel is acknowledged back to the user via return SMS Message. Use any model of cell phone for MyAccess Messaging. REMOTE CONTROL VIA DMP APP The App provides AppleC iPhone and Wad owners, as well as Android users, with the ability to access a number of system functions remotely via cellular connection. As a dealer, the App provides the opportunity to load a company logo into the App. For both residential and commercial system owners, the attractive interface provides fast, easy access to the most commonly used system functions. APP CAPABILITIES At a glance, check system status including programmed areas. Arm or disarm the system in an instant Select from the Home/Sleep/Away arming options for home systems. Select from the All/Perimeter arming options for office systems Select from Area Arming Options Tap any programmed outputs to turn them on or off. Adjust lighting/thermostat/locks Video capability - up to six cameras. remote viewing. XTL SERIES The XTLC (CDMA) is available with on-board cellular which allows for MyAccessTM Messaging Email/SMS message commands to be sent directly to the panel. It is also available with on-board network or WiFi allowing for mobile App Control. This powerful burglary, residential fire, and door access panel provides cellular communication with built-in two-way wireless. CY2631-1 DIGITAL CELLULAR COMMUNICATOR For existing XT &XRió XR350 I XR550 Series panels not originally configured with cellular communications Chi 63. âellülar) JpabilitièThe 263C/263H allows alarm messages to be communicated to an SCS- I R or SCS-VR Receiver over their respective COMA or HSPA+ networks. It provides a fully supervised alarm communication path over the network. The 263C/263H is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply or battery back-up is needed*. Plug-and-play installation makes upgrading your panel quick and easy. The 263H includes a SIM card. The 263C does not include a SIM card and is activated with the MElD number. All modules are ready for activation with SecureCom Wireless. COMMUNICATOR XR1 00IXR500 Series panel users can plug in the 463C expansion card to quickly and easily incorporate cellular communications. In the panel enclosure, it requires no additional enclosures, power supplies, batteries, cabling or conduit connections -simplicity available only from DMR It can be equipped with local antenna that attaches to the pane l, or where necessary for improved signal strength a remote SMA antenna can be used, offering more installation flexibility. The 463C draws half the current of other comparable units. With the long standby battery life of the system batteries, the 463C can continue to provide a communications link for up to 80 hours during a power failure with appropriate standby batteries. The 463C does not include a SIM card and is activated with the MElD number using SecureCom Wireless. CELLULAR COMMUNICATOR The 464-263H or462-263C cellular modules can be plugged onto the XR1 00/XR500 panel boards to add cellular communications inside the panel enclosure. It requires no additional enclosures, power supplies. batteries, cabling or conduit connections. They can be equipped with a local or remote antenna. *A 381 cable is required for the XR1 50 1 XR350 I XR550 Series. The XR500FC Series Fire panels used with the 463C Digital Cellular Communicator has earned the UL 864 listing when used as the primary path (no backup required) for commercial fire installations per NFPA 72. The check-in and fail time settings are programmed for five minutes. When used as the backup path, the 463C provides the security of a communication link that continues to function, even when land lines are cut or compromised. This interface works on the CDMA data networks over a variety of carriers in the USA. TECHNOLOGY OPTIONS Selecting the right Cellular Communicator Built-in COMA 263C/263H 463C 464-263C/464-263H XT301X150 X XR1 00 Series X X XR500 Series X X XTL Series X XR150 I XR350 I XR550 Series X SPECIFICATIONS Primary Power 12 VDC from panel We- DF(263C)) S1andby) Larm =13m: A Current Draw (263H) Standby 24mA Alarm 28mA 463C SPECIFICATIONS Primary Power 12 VDC from panel Current Draw Standby 22mA Alarm 22mA 464-263C/464-263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw Standby 15mA Alarm (Nominal) 48mA Peak (-150mS) 85mA 263C/263H COMPATIBILITY XT Version 112 or higher & XR1 50 I XR350 I XR550 Series Panels (A 381 cable is required for the XR150 I XR350 I XR550 Series) 463C COMPATIBILITY DMP XR1 00/XR500 Series panels using Software Version 202 or higher 464-263C/464-263H COMPATIBILITY DMP XR1 00/XR500 Series panels using Software Version 212 or higher ACCESSORIES 381-2 18" Coax Extension 381-12 12 Coax Extension 381-25 25 Coax Extension 383 Rubber Duck Antenna 386 Wall Mount Antenna Bracket 387-1 3dB Fiberglass Antenna w/bracket 387-2 2dB Attack Enclosure Antenna 387-3 3dB MEG Antenna 387-4 4 SMA to N Extension Cable 387-8 8 SMA to N Extension Cable 387-25 SMA TO N CABLE, 25F1 LMR195 387-50 SMA TO N CABLE, 50F1 LMR1 95 ORDERING INFORMATION 263C/381-2 CDMA Cellular Communicator w/ 381-2 Cable (Verizon) 463C COMA Cellular Communicator (Verizon) 263H HSPA+ Cellular Communicator (AT&T. T-Mobile. (263HCAN - Rogers)) 263H/381-2 HSPA+ Cellular Communicator w/ 381-2 Cable (AT&T. T-Mobile. (263HCAN - Rogers)) 464-263C CDMA Cellular Communicator (Verizon) 464-263H HSPA+ Cellular Communicator (AT&T. T-Mobile. (464-263HCAN - Rogers)) LISTINGS AND APPROVALS 263C/263H/463C California State Fire Marshal (CSFM) 263C/463C/464-263C FCC ID: MIVCNNO301 Industry Canada: 4160ACNN0301 263C/463C/464-263C Verizon Certified 263H PTCRB Certified (AT&T) 263H/464-263H FCC ID: RI7HE91ONA Industry Canada: 5131 AHE91ONA 463C New York City (FDNY COA #6123 & #6145) Underwriters Laboratories (UL) Listed 263C/263H ANSI/UL 294 Access Control System Units ANSI/UL 636 Holdup Alarms Units and Systems Accessory ANSI/UL 985 Household Fire Warning ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglary ANSI/UL 1635 Digital Burglar ANSI/UL 864 Fire-Protective Signaling 9th Edition ((R150 I XR350 I XR550 Series Panels only) 463C ANSI/UL 365 Police Station Connect Burglar Alarm Systems ANSI/UL 985 Household Fire Warning System Units ANSI/UL 1023 Household Burglar Alarm System Units ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units ANSI/UL 864 Control Units for Fire-Protective Signaling Systems 464-263C/464-263H ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station BurglarAlarm Units Underwriters Laboratories Canada (ULC) Listed 263H (XR150 I XR350 I XR550 Series Panels only) ULC S304-06 Central Station Burglar ULC Subject-C1023 Household Burglar ULC/0RD-C1076 Proprietary Burglar ULC S545 Household Fire ULC S559-04 Equipment for Fire Receiving Centers and Systems 464-263H ULC/ORD-C1076 Proprietary Burglar ULC S304-06 Central Station Burglar uperior Notification )ptions - DMP Notification Modules provide quality supervision for faults, such as grounds, shorts, and opens. 12 or 24 VDC, UL Listed devices Devices alert on-site personnel of fire and burglary alarms Silence switch can disable module bell output during service and maintenance Select the module that is best for your application. NOTIFICATION MODULE FEATURES Powered from panel or auxiliary power supply Suitable for use with 12 VDC or 24 VDC devices Supervised Silence Switch disables the bell output during service or maintenance Provide suDervised Style W 2-wire circuit for notification 867 FEATURES Provides Steady, Pulse, Temporal Code 3, and California Schools Code bell outputs Provides supervision for opens, shorts, and ground fault conditions on the bell circuit On-board status LED indicates Dane[ communication is - INSTALLING THE 865 DESCRIPTION 867 DESCRIPTION NOTIFICATION MODULES The 865 is suitable for use with 2- or The 867 connects to the panel LX-Bus You can install the Notification 4-wire Style Y, Z, W, or X circuits. It and provides one supervised Style Modules in any of the panel enclosure provides one Trouble and one Ground W circuit, and four LEDs to indicate three-hole mounting locations using Fault LED and a set of trouble contacts circuit Trouble and Ground Fault the plastic standoffs provided, to indicate off normal conditions. conditions. NOTIFICATION APPLIANCES The 865, 866, and 867 Modules easily connect notification appliances, such as horns and strobes. By connecting the appliances in parallel, it is possible to connect several appliances to one module. Refer to the module installation sheet for more information. AUXILIARY POWER SUPPLY You can connect a maximum 5 Amp, 12 or 24 VDC UL listed auxiliary power supply to the Notification Modules to support alarm power requirements beyond the panel alarm output capacity. SILENCE SWITCH OPERATION The Silence switch on the Notification Modules allows technicians to test or perform maintenance on the DMP fire system without sounding the building's fire alarm notification devices. POWER SUPPLY SUPERVISION The panel can supervise the auxiliary power supply through the normally closed trouble contacts on the power supply that also connect to terminals 7 and 8 on the 866 and 867 Modules. When the bell circuit is in a bad condition, the modules indicate the bad condition to the panel. 865 SELECTABLE CIRCUIT STYLES By setting a jumper on the 865 Module, you may use Style W (2-wire) or Style X (4-wire) notification circuits to connect appliances. You may also use Style Y (2-wire) or Style Z (4-wire) circuits. This flexibility allows the use of one module in a variety of applications. 866 DESCRIPTION The 866 Notification Module provides one 5 Amp Style W notification circuit for supervising UL listed, polarized notification devices such as bells, strobes, and horns. The 866 is compatible with DMP Command Processorlm panels. MULTIPLE 866 MODULES You may install up to 25 Model 866 Style W Notification Modules on each XR500 Series XR200, XR200-485 panel by using the relay outputs available on the panel. 867 ADDRESSING The 867 has two pairs of rotary switches. One pair sets the module Bell Relay Address. The second pair sets the Supervisory zone address. Having a separate Bell Relay Address allows multiple modules to be activated in groups and yet monitored by individual Supervisory zones. 867 BELL RING STYLE You can specify the bell output cadence on the 867 module by setting the Bell Ring Style jumper for Steady, Pulsed, Temporal Code 3, or California Schools. The 867 can then be activated by the Fire Bell output or by a panel Zone Alarm Output. POWER SUPPLIES 502-12 Provides 2 Amps ® 12 VDC 505-12/LX Provides 5 Amps ® 12 VDC 508 8 Amps @12or24VDC PANEL COMPATIBILITY 866 and 865 Modules - all DMP Command Processor"' panels. 867 Module - XR500 Series, XR200, and XR200-485, Command Processorw Panels. 865 MODULE SPECIFICATIONS Operating Voltage 9.6 to 14.2 VDC from panel Current Draw Standby: 26mA, Maximum: 85mA Maximum Alarm 5 Amps ® up to 30 VDC Circuit Styles One 2-wire Style W or Y or One 4-wire Style X or Z 1jEiWO im Operating Voltage 12 VDC Current Draw (from panel) Standby: 45mA, Maximum: 75mA Contact Ratings Alarm 5 Amps at 24 VDC resistive Trouble 2 Amps at 30 VDC resistive 867 MODULE SPECIFICATIONS Operating Voltage LX-Bus: 8.0 to 15.0 VDC Bell Power: 10.2 to 28 VDC Operating Current LX-Bus: 30mA maximum Bell Power: 30mA standby, 8OmA maximum Alarm-Switching Current 5 Amps at 12 or 24 VDC Module Dimensions 3" x 5" LISTINGS AND APPROVALS Underwriters Laboratories (UL) Listed UL 864 Fire Protective Signaling UL 985 Household Fire Warning UL 1023 Household Burglary FCC Part 15 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 Expand your DMP Command ProcessorThl panel options with a wide array of expansion modules. Add supervised Class B burglary zones. Connect non-powered burglary or fire type devices for intrusion, gLassbreak, and motion detection. Add 12 VDC zones for addressable 2-wire smoke detectors with 715 moduels. cim pie Expansion Iutio ns ZONE EXPANSION MODULE FEATURES Provides Class B zones for burglary and fire • Easy connection to 4-wire keypad or LX-Bus'M Compatible with DMP Command Processor Panels that allow • Proven design ensures stability and performance zone expansion • Data LED on zone expander indicates good panel Suitable for mounting near protection devices communication Connect devices using 4-wire bus • Durable and attractive plastic or metal housing USE ON THE DMP LX-BUSTm 708 BUS EXTENDER MODULES 710 The modules can be used on the LX-Buslm The 708 Bus Extender Modules allow you As a splitter, the 710 provides superior of DMP Command ProcessorA Panels. The to increase the length of wire used to run mechanical wire connecting capability for modules connect to the 4-wire bus and an LX-Bus or keypad bus by a maximum of up to three additional 12 VDC LX-Bus or use only one zone address. To assign an 4,000 feet, while providing immunity to keypad bus circuits. This makes the 710 additional zone expander use the next noise on the wires. The 708 Bus Extenders module an excellent junction box when available zone address. are received from the factory as a pair of terminating multiple LX-Bus/keypad bus CONNECT TO KEYPAD BUS modules that connect between the panel runs at one location. As a repeater, the You can also use the modules as an and LX-Bus or keypad bus devices. 710 module can be installed at the end of addressed device on the keypad data bus of DMP Command Processor panels. Simply set the module to an available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711, 714, 714-8, 714-16, 715, 715-8, 715-16, and 725 modules by setting two on-board rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone Expansion Modules are mounted in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the cover snaps on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708, 710, 710F, and 725 modules inside a DMP enclosure using the 3-hole configuration and the provided standoffs. The 712-8 only mounts using the 3-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panel's available zone types for use in burglary applications including Arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorals to remote DMP SCS-I R Receivers. Use the 708 Modules for applications that include running wire over long distances, through noisy environments, or where the bus is bundled with other wires, such as telephone company wire. The 708 Extender can be used on all DMP panels. 'P 708 FEATURES Extends Keypad Bus or LX-Bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710171 OF BUS SPLUTTER! REPEATER MODULES The 710 and 710F Bus Splitter/Repeater Modules allow you to expand the typical LX-Bus or Keypad bus installation both in the number of devices and the length of the wire used. Each 710/710F Module provides three bus connections each up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! an LA-bus 01 keypad uus circuit to auow an additional circuit to be added, thus increasing the total wire length. 710F As well as providing all of the functions of the 710 listed above, the 710F also allows you to use the 725 Zone Expander to expand the number of 24 VDC zones. The 710F Bus Splitter/Repeater allows the connection of a 24 VDC power supply to the 725 to power smoke detectors and isolate the 24 Volt source from the panel. Therefore, the 71 OF must be used when using the 725 Zone Expander. 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP Command Processor panels using the 712-8 Module. The 712-8 Module is compatible with many intrusion contacts, glassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or Keypad bus operation Compatible with all DMP Command Processor panels Expand systems by daisy chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using 3-hole pattern Separate zone 1K End-of-Line resistors included SIE SI—IEEF -- 7141715 ZONE EXPANDERS 714-8,(7j4.(6l 5-8, AND 725 24VDC EXPANSION The 714 contains four Class B burglary 715-16 DESCRIPTION MODULE zones and is suitable for use with burglary The expanders are housed in a Model The 725 provides four 24 VDC powered and fire devices that are normally opened 340 locking metal enclosure suitable zones that enable you to connect or normally closed. Individual zones are for mounting in a remote location. 2-wire smoke detectors to the XR500 supervised with 1k Ohm EOL resistors and Each expander provides screw terminal Series, XR2500F, XR200, and XR200-485 can be programmed with any burglary or strips for zone inputs and data bus Command Processor Panels. As a result, fire zone type. connections, a two position jumper to the 725 provides you the flexibility to The 715 contains four Class B powered zones and is suitable for use with 12 VDC, 2-wire smoke detectors and non-powered on the 715 are supervised with a 3.3k Ohm EOL resistor and can be programmed with any burglary or fire zone type. fire or burglary devices. Individual zones aesignate connection to tne Keypad bus retront a 14 VOLt system witnout the need or the LX-Bus, and an LED to indicate to run more wire or change to 12 Volt communication with the panel. Separate smoke detectors. zone End-of-Line resistors are included with each expander. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 718T Plug-in Screw Terminal. The enclosure can also accommodate the 719T Terminal Boards for the 714 or the 720T Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1K EOL resistors are included with the 719T and 3.3K resistors are included with the 720T. 714171 FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-8 6_EXPANDERS The 714-8 Expander contains 8 ClassB zones. 714-16 Expander.contains_161 (Class_B_zones.Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1k Ohm EOL resistor and can be programmed as any zone type. 71 S-8171 5-16 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. 7I4-8,II)7I 5-8, AND 715-16FEATURES 8 or(protectionzdnespe (nder) Durable metal enclosure housing with lock and key Individual screw terminals accommodate 14 to 22 gauge wire for easy connection Suitable for mounting in a remote location 725 FEATURES Provides four 24 VDC zones Sensor reset performed through panel relay or 716 Output Expander Powered from 24 VDC power supply Supervised operation 24 Volt surge protection from 71 OF Provides ability to use 24 VDC 2-wire smoke detectors Easily mounted in 3-hole pattern 711 DESCRIPTION The 711 Zone Expansion Module connects to the panel's 4-wire keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. 711 FEATURES Single-zone expander Rugged screw terminals accommodate 14 to 22 AWG Board fits in Radionics POPIT housing Easy rotary switch addressing Digital iVlonitwIng Product. IN - - - Ula ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP Zone Expansion Module. Module Address Number of Zones 3-Hole Plastic Case Operating Voltage Compatible Panels 708 N/A N/A Yes Yes 12 VDC All DMP 12 VDC 710 N/A N/A Yes Yes 12 VDC 710F N/A N/A Yes Yes 712-8 Dip Switch 8 Yes No 12 VDC XR500 Series, XR2500F, XRSuper6, XR2O, XR4O, XRZOO, XR200-485 12 VDC 711 Rotary 1 No Yes 12 VDC 714 Rotary 4 Class B No Yes 12 VDC 714-8 Rotary 8 Class B No Metal Enclosure 12 VDC '714'"i6 Rotary 16 Class B No Metal Enclosure 12 VDC 715 Rotary 4 Class B No Yes 12 VDC 715-8 Rotary 8 Class B No Metal Enclosure 12 VDC 715-16 Rotary 16 Class B No Metal Enclosure r7T5777. Rotary j 4 24 VDC Class B No Yes 24 VDC XR500 Series, XR2500F, XR200, XR200-485 MODULE SPECIFICATIONS 7141715 SPECIFICATIONS 708 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Voltage 8.8 to 15.0 VDC Operating Current Operating Current 20mA Per Pair 714 Average 7mA + 1.6mA per zone Dimensions 4.5" X 2.75" X 1.75" Alarm 7mA + 2mA per zone Maximum Distance 4,000 feet between the two 715 Average 7mA + 4mA per zone + 0.1 per 2-wire smoke 708 Modules Alarm 7mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm 7I0I7I OF SPECIFICATIONS Dimensions 4.5" X 2.75" X 1.75" Operating Voltage 8.8 to 15.0 VDC 714-8, 6. 715-8, AND 715-16 SPECIFICATIONS Operating Current 710 30mA Operating Voltage 8.8 to 15.0 VDC 710F 40mA Operating Current Dimensions 4.5" X 2.75" X 1.75" 811) __ Distance 2,500 feet (one module), (iij) f2OrnA + 1.6mA _______ per zon3 15,000 feet maximum (Alarm) OmA + 2mA per zone) 711 SPECIFICATIONS 715-8/16 Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Operating Voltage 8.8 to 15.0 VDC Alarm 20mA + 58mA per shorted zone + 0.1 per Operating Current 2-wire smoke + 30mA per smoke in alarm Average 7mA + 1.6mA per active zone Enclosure 20-Gauge cold-rolled steel Alarm 7mA + 2mA per zone in alarm Dimensions 12.5" W x 11.5" H x 3.5" D Zone Voltage 5 VDC (1.6mA across EOL) 714-8/-16 Color Gray Dimensions 4.5" X 2.75" X 1.75" 715-8/-16 Color Red 712-8 SPECIFICATIONS LISTINGS AND APPROVALS Operating Voltage 8.8 to 15.0 VDC Refer to the appropriate panel programming and installation guide Current Draw 17mA + 1.6mA per active zone for specific compliance listings for installation and programming 17mA + 2mA per zone in alarm requirements necessary to meet a particular approval. Dimensions 4.5" H 2.5" W Underwriters Laboratories (UL) Listed 725 SPECIFICATIONS California State Fire Marshall (CSFM) Operating Voltage 24 VDC Nominal New York City MEA accepted (711, 714, 715 only) Average Current 8mA + 4mA per active zone Alarm Current 8mA + 4mA per active zone For additional information, access www.dmp.com and select + 30mA per smoke in alarm + 47mA per shorted device Compliance. EOL Resistor Model 316 6.8k EOL Now 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 Description The Model 714-8,jJ,)715 8, and 715 you to increase the number of protection zones available on a DMP panel The 714 8 and714 1de anadditionaieight orixteen superid zoneJfor connecting burglary and non-powered fire alarm initiating devices to the panel. The 715-8 and 715-16 provide an additional eight or sixteen 12 VDC ungrounded (Class B, Style A) powered zones for connecting two-wire smoke detectors. Please see the panel installation guide for details on selecting compatible 2-wire smoke detectors. Each of the zone expanders provide terminal strips for zone inputs and wiring connections, a jumper for LX-Bus", or keypad bus designation, and a transmit data LED to indicate panel communication. The expanders mount in a Model 340 enclosure with Lock. Separate zone end-of-line resistors and a key are included. ALL fire device installations must be in accordance with the manufacturer instructions, NFPA standards, and Authority Having Jurisdiction (AHJ) requirements. Mounting the Enclosure Mount the zone expander metal enclosure in a secure, dry place to protect from damage due to tampering or the elements. It is not necessary to remove the zone expander circuit board when installing the enclosure. The enclosure can be surface or flush mounted using the holes provided. Each of the four sides have dual 1/2" and 3/4" conduit knockouts for running wires out of the enclosure. Keypad or LX-Bus Jumper Setting Each of the zone expanders provide a 3-pin header with jumper (J2) used to select the connection type to the panel. If the expander is connected to the LX-Bus, place the J2 jumper header on the far right two pins. Place the J2 jumper header on the far Left two pins when connected to the keypad bus. See Figure 1. Keypad Bus )2ths 48 and 714-16: Use 1k EOL - For listed lire applications use Model 310 Operation 715-8 and 715-16: Use 3.3k EOL Model 309 ___ hon 6Co Fault detecti LX-BuS at l5000hms or less 715-8 or -16 Ground Fault Detection 29+ Z13+ at 80 Ohms or less Tfl On 25- Z9- Operating Range 25+ Z13_Normal e ® z6+ 714-8 or -16 650-2100 Ohms 32 Z8- Z18- 1 715a or -16 1200 - 6000 Ohms To Ail zones are supervised r37 211 ToLX-Busor Z15 28+ IteypadBus Z12+ GRN ELK 28- Z12- .i10 312 jq 33k 801. Model 309 Maximum line resistance 100 ohms. MI circuits are supervised and power limited. See the appropriate Installation Guide For the — number and type of approved 2-wire Smoke Detectors (j) — L2-W!re To panel smoke detector power circuit e and Negative - Power [ To zone Positive and Negative 3.3k EOL Modal 359 Figure 1: Expander Wiring Diagram Setting the Address Each zone expander has two rotary switches labeled TENS and ONES to configure the expander address from 00 to 99. To set the address, use a small slotted screwdriver and gently turn the center arrow on the switch clockwise to the number that matches the address. See Figure 2. TENS ONES -f To ca Figure 2: Address Switches 81 Keypad Bus Addressing The ONES rotary switch must be set to a starting address that communicates the status of the first four zones (ZI through Z4) on the expansion module. The next consecutive keypad address is automatically used to communicate the status of the next four zones (Z5 through Z8), etc. For example, when you set the TENS switch to 0 and the ONES switch to 2, the first four expander zones respond as zones 21 through 24. Expander zones 5 through 8 respond as panel zones 31 through 34; zones 9 through 12 respond as panel zones 41 through 44; and zones 13 through 16 respond as panel zones 51 through 54. Refer to Tables I and 2 for keypad bus zone numbers and the panels where they operate. Start Address Expander Zones 1-4 I 5-8 1 9-12 I 13-16 Switches Tens Ones XR500 or XR350/XR550 Series Panel Zones o 1 11 to 14 21 t024 31 t034 41 to 44 o 2 21 t024 31 t034 41 to 44 51 to 54 o 3 31 to 34 41 t044 51 t054 61 t064 0 4 41 to 44 51 to 54 61 to 64 71 t074 0 5 51 t054 61 t064 71 t074 81 t084 0 6 61 t064 71 t074 81 to 84 91 to 94 0 7 71 t074 81 to 84 91 to 94 101 to 104 0 8 81 to 84 91 to 94 101 to 104 111 to 114 0 9 91 to 94 101 to 104 111 to 114 121 to 124 1 0 101 to 104 111 to 114 121 to 124 131 to 134 1 1 111to114 121to124 131t0134 141to144 1 2 121 to 124 131 to 134 141 to 144 151 to 154 1 3 131 to 134 141 to 144 151 to 154 161 to 164 1 4 141 to 144 151 to 154 161 to 164 None 1 5 151 to 154 161 to 164 None None 1 6 161 to 164 None None None Table 1: Keypad Bus Zone Numbers Start Address Expander Zones 1-4 5-8 I 9-12 I 13-16 Switches Tens Ones Panel Zones XT30, XT50, XRI 00 or XRI 50 0 1 11 to 14 21 to 24 31 t034 41 t044 0 2 21 to 24 31 to 34 41 t044 51 t054 0 3 31 to 34 41 t044 51 t054 61 to 64 0 4 41 t044 51 to 54 61 to 64 71 t074 0 5 51 to 54 61 to 64 71 to 74 81 to 84 0 6 61 to 64 71 to 74 81 to 84 None 0 7 71 to 74 81 to 84 None None 0 8 81 to 84 None None I None Table 2: Keypad Bus Zone Numbers Digital Monitoring Products 714-715 Installation Guide 2 (PC-Bus Addressing' When connecting to the LX-Bus, the rotary switch settings on the expanders must match the second two digits of the first panel zone being used. The next 15 zone addresses are automatically used to communicate the status of the expander zones 2 through 16. For example, if you set the TENS switch to 3 and the ONES switch to 2, the sixteen zones on the expander respond as panel zones 532 to 547. When connected to LX-Bus 2, the zones respond as 632 to 647. 'Note:The LX Bus provides zones 500 through 599, 600 through 699, 700 through 799, 800 through 899 and 900 through 999 on XR500 Series or XR350/XR550 Series panels. On XR1 00 and XR1 50 panels the LX-Bus provides zones 500 through 599. When addressing the module, use an address that provides the proper number of zones. For example, if you set the switch address on the module to 99, you can only use one zone as shown in Table 3 below. Start Address Panel LX-Bus Numbers and their corresponding Zone Numbers Switch Tens Ones XRIOO - and Series xR15o: XR500 and XR550 Series - XR350 Series (LX500 - LX700) - 1(LX500) 1(LX500) 2(LX600) 3(LX700) 4(LX800) 5(LX900) 0 0 500 500 600 700 800 900 o 1 501 501 601 701 801 901 0 2 502 502 602 702 802 902 0 1 3 503 503 603 703 803 903 0 4 504 504 604 704 804 904 9 5 595 595 695 795 895 995 9 6 596 596 696 796 896 996 9 1 7 1 597 597 697 797 897 997 9 8 598 598 698 798 898 998 9 1 9 599 599 699 799 899 999 Table 3: LX-Bus Zone Numbers Wiring Each zone expander can connect to a panel keypad bus. Also, the zone expander can connect to an XR1 00/XR500 or XR1 50/XR350/XR550 Series panel LX-Bus. On an XRI00/XR500 Series, the zone expander can connect directly to the LX-Bus Connector (J22) on the panel or use an LX-Bus Interface card such as a 481 or 463C, as shown in Figure 1. All circuits are power limited. On an XR1 50/XR350/XR550 Series: connect the zone expander directly to the LX500 - LX900 connectors on the panel. Note: 481, 463C, 462P, and 462N LX-Bus Interface Cards are not for use with XR1 50/XR350/XR550 Series panels. Wiring the 715-8/16 Module For the 715-8/16 module, connect the Red wire to the panel Smoke power terminal. This allows Sensor Reset to drop power to the module and devices connected to its zones. Alternately, connect Red to a regulated, power limited power supply listed for Fire Protective Signaling through a Model 716 relay. Use the Sensor Reset Output programming to drop power to the 715-8/16 Module. 714-715 Installation Guide Digital Monitoring Products 3 Average 20mA + 1 .6mA per zone Alarm 20mA + 2mA per zone 715ä7i6 Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 20mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm Enclosure Specifications Enclosure 20 Gauge cold rolled steel Dimensions 12.5" Wx 11.5" H x 3.5" D 714-8/-16 Color Gray 715-8/.16 Color Red Compatibility XT30/XT50 Series panels XRI00/XR500 Series panels XRI 50/XR350/XR550 Senes Wiring Specifications for Keypad and LX-Bus DMP recommends using 18 or 22-gauge unshielded wire for all keypad and LX-Bus circuits. Do Not use twisted pair or shielded wire for LX-Bus and keypad bus data circuits. To maintain auxiliary power integrity when using 22-gauge wire do not exceed 500 feet. When using 18-gauge wire do not exceed 1,000 feet. Install an additional power supply to increase the wire Length or add devices. Maximum distance for any one circuit (Length of wire) is 2,500 feet regardless of the wire gauge. This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2,500 feet. As wire distance from the panel increases, DC voltage on the wire decreases. Maximum number of devices per 2,500 feet circuit is 40. Note: Each panel allows a specific number of supervised keypads. Add additional keypads in the unsupervised mode. Refer to the panel installation guide for the specific number of supervised keypads allowed. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0 VDC. If the voltage V at any device is Less than the required level, add an auxiliary power supply at the end of the circuit. When voltage is too low, the devices cannot operate properly. For additional information refer to the panel installation guide and LX-Bus/Keypad Bus Wiring Application Note (LT-2031) or the 710 Installation Guide (LT-0310). Compliance Listing Specifications UL To comply with ANSI/UL 365 Police-Connected Burglary System or ANSI/UL 609 Local Burglary Alarm Systems, the module must be mounted in the supplied, UL Listed enclosure with a tamper. Any power supply used in a fire Listed installation must be regulated, power Limited, and listed for Fire Protective Signaling. ULC Commercial Burglary (XR100/XR500 Series or XR150/XR350/XR550 Series Panels) A DMP Model 307 Clip-on Tamper Switch programmed as a 24-Hour zone is required on the zone expander enclosure. The 714/715 zones can be installed in Medium or High Risk applications when two zones are used as shown in the Dual Zone Protection diagram in the XR100/XR500 or XRI50/XR350/XR550 Canadian Installation guides. Otherwise, 714/715 zones can only be used in Low Risk Applications. ULC Residential Fire Refer to the table below for ULC approved 2-Wire Smoke Detectors. Refer to the panel installation guide for the complete list of UL approved smoke detectors. Manufacturer Model Detector ID DC Voltage Range # of Detectors SentroL/ESL I 528B, 528BXT I S09A 6.5-20 12 Specifications Operating Voltage OperatingCurrent MW Listings and Approvals 8.8 to 15.0 VDC California State Fire Marshal (CSFM) New York City (FDNY COA #6123) New York City 1100 Series Wireless (FDNY COA #6145) Underwriters Laboratories (UL) Listed ANSI/UL 365 Police Station Connect Burglar Alarm Syste ANSI/UL 609 Local Burglar Alarm Units ft Systems ANSI/UL 864 Fire Protective Signaling Systems ANSI/UL 985 Household Fire Warning System Units ANSI/UL 1023 Household Burglar Alarm System Units ANSI/UL 1076 Proprietary Burglar Alarm Units ft Systems ANSI/UL 1610 Central Station Burglar Alarm Units ANSI/UL 1635 Digital Alarm Communication System Units Underwriters Laboratories Canada (ULC) Listed ULC Subject-C1023 Household Burglar ULC/ORD-C1076 Proprietary Burglar ULC S304 Central Station Burglar ULC 5545 Household Fire 2500 North Partnershiø Boulevard Springfield, Missouri 65803-8877 U C annunciation solutions - DMP Fire Command Keypads provide a variety of fire annunciation solutions for residential and commercial fire applications. The 630F provides 32-character full text LCD display of system events and menu prompts for efficient, easy use. The keypad offers simple, one-button access to common features, including: Silence alarms Reset sensors Test the system Perform a fire drill 63OFDMP FIRE COMMAND KEVPAb FEATURES Simple harness connection to 4-wire keypad bus At-a-glance system status Powered from panel or auxiliary power supply Optional backboxes for conduit or wall mount applications Attractive non-obtrusive designs 2-button Panic keys 32-character LCD display Flush or Surface mount Keyswitch enables single button operation Full operation with authorized code Built-in diagnostics AC Power, Trouble. Alarm LED Compatible with XR1 00IXR500 Series System events display in plain English te3oF.RQg ANNUNcIATOR The 630F Fire Command Center offers a 32-character full text LCD readout that displays system events and menu prompts. making it efficient and easy-to-use. The backbox and trim frame provide an attractive installation. The keypad can either be flush-mounted or surface-mounted. 630F Keypad BUILT-IN DIAGNOSTICS An internal diagnostics program lets installers and service technicians test the operation of the keypad at any time without disabling the system. SUPERVISED AND UNSUPERVISED OPERATION The 630F keypad can be programmed for supervised or unsupervised operation on the keypad data bus, increasing the overall number of keypads you can install to provide maximum flexibility. When supervised, the keypad occupies its own address. Unsupervised operation allows you to install multiple keypads on the bus with the same address. STATUS LEDS The Green Power LED turns on when primary AC or DC power to the panel is at an acceptable level and flashes when its battery is low or missing. A Yellow Trouble LED turns on when either the panel has failed to communicate with the central station receiver or when phone line 1 or 2 is in a bad condition. SINGLE-BUTTON OPERATION The 630F Fire Command Center has a factory installed keyswitch that enables the four function buttons—Alarm Silence. System Reset, System Test, and Fire Drill. The user can also access these four functions and many more through the User Menu by entering a valid user code. 30F SPIFICATIONS) KEYPAD ACCESSORIES Operating Voltage 8.5 to 15 VDC 635 1.75" 630F Alternate Surface Mount Backbox (Current Draw) (3mA standb) 635F 2.5" 630F Flush Mount Replacement Backbox 92mAmaximum) 300 4-wire Replacement Harness LISTINGS AND APPROVALS Trim Frame Dimensions 10.4" W X 7.0" H xl .T 0 California State Fire Marshal (CSFM) Backbox Dimensions 8.75"W x 6.375"H x 2.5"D New York City (FDNY COA #6055) Panel Compatibility XR100 and XR500 Series Panels FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Control Units for Fire Protective Signaling ANSI/UL 985 Household Fire Warning For additional information, access www.dmp.com and select Compliance. PIE M.nIk.g Intrusion Fire Access Network Cellular CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 2 CATEGORY: LISTEE: Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 831-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN (MoelXRiXR350 and XR550com0it__abuiglary ali control units] Local remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: (XR150)XR350, XR550:[MaJnBoa'àJ 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure (630F Su'èvisea LCD Key) 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers e7 711 714 714-8,(7fij715 7158 715-16€ZoneExpands) *711S: Zone Expander (NOT for use with XR350) Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263H (ellular Conmunicator (May àsthe standalone primary_communicator)') 263LTE: Cellular Communicator (NOT for use with XR350) (May be used as the standalone primary communicator)________ 865 867 iaiiing Module) 869: Initiating Module 303: Reset/Silence Switch IlOOX, IIOOXH: RF Wireless Receiver IlOOR: Wireless Repeater 1103: Wireless Transmitter Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (tingExpj3 ü1é;:3O,2O Authorized By: DAViD CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 1135: Wireless Siren RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not - an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NPINPX SERIES Tr SEALED RECHARGEABLE LEAD-ACID BATTERIES YUASA (Np/.NPX INDUSTRIAL BATTER Yuasa brand NP and NPX batteries give excellent performance in either float or cyclic applications. These batteries are designed for light duty cyclic applications, fire and security systems, Emergency lighting, solar and wind support systems, UPS systems and toys! / POWERING THE NEXT GENERATION CGSYUASA ROATWWICEUFE NPSRiES t1lWi* Ilti !2 fOtJM('IJ1 A'L Eftn2rrc2x(tot -If) rn, S LILt .:,- . ----- --cu 1 ._L )y NP/NPX SERIES YUASA SEALED RECHARGEABLE LEAD-ACID BATTERIES The Yuasa brand of small vaLve-reguLated batteries have, since their introduction, set the standard for quality and excellence in the field of rechargeable sealed Lead-acid battery technology. This standard has been used as a benchmark in applications such as security, uninterruptibLe power supplies (UPS). emergency lights and medical equipment. Anywhere the need for reliable and dependable back-up power is required, Yuasa sets the pace. The Yuasa brand NP product line covers the entire spectrum of battery sizes, ranging from 1.2 Ah to 65Ah in 6 and 12 volt varieties. Yuasa also offers a full line of flame retardant batteries (UL9440, LOI 30). Designated "FR", these batteries comply with UL1778 flame retardant specifications for UPS. Yuasa also offers the NPX Series Batteries, designed for high rate discharge applications. These batteries are used primarily where high wattage is required for a short duration. With 50% more wattage available and a 30% reduction in size over conventional batteries, the NPX Series offers a superior value, especially in UPS applications. PAOP5t'CHARGING VOLTAGE AND 1EMPMTI,1E. p" Is at — 5 1.1 ILI - - -- - - 144 - - I its i H - - *:M ai -N 14. oftys 1$ a- 4" •a *NT*AiiJR1 cHAtCmG cA*cimIsics I' llllq(I1 IV •%rqii ! ' its Ito -- IM Ao SAO L SAO :.: a caIciGCvp,tuiT 5 0 is asap as ii is cakRc.I Net TiiIIflU* / CGSYUASA OS Yuasa Energy Solutions, Inc. 2 (RhCIectrk)__ c2; (okeDetectors, System Sensor j3' series smoke detectors represer significant advancement in conventional detect) OF SYSTEM Z IN, SENSOR® The P family is founded on three principles: instal. ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® LISTED Z 0 MEA MSFM APPROVED approved approved 4%). S911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design.This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, P heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the P protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZWalk loop test feature is available on 2-wire i detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. ('h Smoke Detector Smoke detector shall be a System Sensor i3l Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-8) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2W1-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. UElectrical Specifications Operating Voltage Nominal: 1 2/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltacie 3096 peak to peak of applied voltage 50 pA maximum 4-wire: 20 mA @1 23 mA @ 24V Peak Standby Current 2-wire: 100 pA 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 05 A @ 30V AC/DC Physical Specifications Dimensions (including base) 53 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 63 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-8: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (572°C) fixed Freeze Trouble 2W1-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal InputTerminals 14 to 22AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes LED Mode Green LED Red LED Power-Up Sequence for LED Indication Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal (WB. No 'iflm. 2-wire AlarmIumflh1 130 mA max. limited by control panel 2W1-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4W1-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module SENS-RDR Sensitivity reader RT Removal / replacement tool A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter "S 5EjIJ5QR Q20D9 System Sensor 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2 Fax: 630-377-6495 - COt4PTIBILIrY Compatibility 26.1 (Compatible 2-Wire Smoke Detector, Panel terminals 25 through 28 provide two resettabLe Class B, Style A, 2-wire powered zones. For programming purposes the zone numbers are 9 and 10. Note: The maximum wire Length for either zone 9 or zone 10 is 3000 feet using 18 AWG or 1000 feet using 22 AWG. The maximum voltage is 13.8 Vdc and the maximum normal standby current is 1 .25mA DC. The maximum Line impedance is 100 Ohms. The maximum short circuit current is 56mA. When using zone expansion modules, use Model 309 EOL resistors. The compatibility identifier for the zones is A. VNote: Do not mix detectors from different manufacturers on the same zone. Caution: Performing a Sensor Reset momentarily drops power to the devices on Zones 9 and 10. The panel views these zones (9 and 10) as "Open" while the power is absent. Manufacturer ',Model, Detector Base Base DC # of Zone Panel ID ID Voltage Detectors Expansion Zones Range (12V/24V) Modules Hochiki SLR-835B-2 SLR-835BH-2 HD-6 N/A 8-35 14 715, 715-8, 715-16 9 & 10 EST 521B, 521BxT, SO9A 6.5-20 12 715, 715-8, 9 & 10 521NB, 521NBXT 715-16 (System Sensoi 2W-B, 2WT-B A 8.5-35 10 715 , 715-8, & 16" 715-16 System Sensor 2WTA-B A (*) 8.5-35 12 715,715-8, 715-16 9 a io System Sensor 2WTR-B A (*) 8.5-35 1 715,715-8, 715-16 9 & io System Sensor 1151, 2151 A BIIOPL, B401 ____________ ______ 8.5-35 ________ 10 ___________ 715, 715-8, 715-16 9 & 10 (*) = Must be used in conjunction with System Sensor Polarity Reversal Module model RRS-MOD. See 1.19 for Installation Diagram 26.2 Notification Appliances The following table indicates the approved notification appliances that can be used with the XR550 Series system. Wheelock Model No. Description Max No. of Appliances using 56 VA/100 VA MT-12/24 Multi-tone Horn 8 MB-G6-12 Bell, 6 inch 16 MB-GI0-12 Bell, 10 inch 16 ST Series Strobe, 15/75 candela 5 HS Series Horn Strobe, 15/75 candela 5 SM-12/24-R Sync Module, Single circuit 24.3 Access Control Devices The followinQ devices are comDatibLe with the XRI 50/XR350/XR550 Series øanels. Access Control 734/734N Wiegand Interface Module Proximity reader connector OP-08CB Motion Detector Infrared sensor PP-6005B Proxpoint Plus® Reader Proximity reader MP-5365 Miniprox® Reader Slimline proximity reader PR-5355-AGK14 Long range reader with keypad and sounder PR-5455 ProxPro® II Reader Long range reader with sounder MX-5375 Maxi-Prox Reader Long range reader compatible with 1351 Prox Pass XR150/XR350/XR550 Series Listing GuidE Digital Monitoring Products 67 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (72721653 52) Page 1 of I CATEGORY: - SM .kE DETECTORSYSTEM TYPE-PHOTOELECTRIC] LISTEE Div 6f Honeywell In[ih3825 Ohio Ave St Charles IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN (ModeIs 2WB2W B 4W-13 and 4WT-Bfphotoelectnc type smoke detector Models 2W-13 and 2W1-13 are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-13 employ a thermistor type heat sensor (135SF). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 itihip Authorized By: DAVID CASTIL.L.O, Program Coordinator Fire Engineering Division W E3 Simple operation provides instant alarm The 850 Series Fire Alarm Pull stations offer quick and simple operation that's economical and reliable. Available in single or dual-action manual pulls SPST contacts and terminal strip connections Gold-plated contacts to avoid the risk of corrosion FEATURES Approvals: UL and CSFM Americans with Disabilities Act (ADA) compliant Die-cast metal construction Reset key Mounts on standard single-gang box Optional surface and weatherproof backboxes available High-gloss red enamel finish Scored acrylic breakrod _33 S Ffl JE fFUJ FiJi... 1Th DESCRIPTION The DMP 850 Series Fire Alarm Pull MOUNTING OPTIONS A variety of mounting options are 850D OPERATJON__. - On the Model 85!D Dual Actio ..fl) Station is a high quality, die-cast available for the 850 series. It can be jStation the push bar rotates inward metal manual pull station available flush mounted to a standard single gang alLowing the PULL handle to be grasped in either single-action or dual-action switch box or surface mounted in two in a one handed motion. configurations with SPST contacts and optional configurations. The Model terminal strip connections. The normally 850-SB Interior Surface Backbox or the ADDRESSABLE ZONE open contact, which closes when the pull Model 850-WP Weatherproof Backbox To create an addressable reporting zone station is activated, is rated for 1 Amp® both allow conduit connection to the for the 850 Series, install a Model 711 30 VDC. The contacts are gold-plated to 850 Series Pull Stations. Zone Expansion module. avoid corrosion risks. Scored acrylic breakrods are used with the 850 series. COMPLIANCE The 850 series has been tested by UL for compliance to the latest requirements of the ADA. 850S OPERATION The Model 850S Single Action Pull Station is operated by pulling the handle on the front of the station as far down as it goes. When the handle locks into place it is easily visible from up to 50 feet. Reset the handle by opening the station with the supplied key, placing the handle in the normal upright position and re-locking the station. PULL Screw Terminals To next To Fire Alarm device or Control Panel - EOL resistor Model 850 Wiring Diagram ORDERING INFORMATION 850S Single-action pull station 1~0 JD tälátióPUllithtiOn) 850-SB Interior surface sheetmetal backbox 850-WP Weatherproof surface die-cast backbox 850-AR Scored acrylic breakrods (1 dozen) 850S/711 Single-action pull station w/addressable module 850D/711 Dual-action pull station w/addressable module Note: All models are supplied with one scored acrylic breakrod and one key. SPECIFICATIONS Switch Rating 1 Amp ® 30 VDC Dimensions 4.75" H x 3.25" W x 2.25" D Color Red w/raised white letters, white PULL handle w/raised red letters COMPATIBILITY The 850 Series Fire Pull Station is compatible with all DMP Command Processors. MM Digital Manitanng Product. 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 IF CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL OU FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 0-.;000 LISTING SERVICE LISTING No. t7.150-1157•:O112J Page 1 of I CATEGORY: LISTEE: 175700 N. Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 831-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN (Models 850D (key lock__push bar)and 850S (key lock no push bar)oncoded manual p (táiñsSuitable for outdoor use when installed with Model 850-WP back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *Rev 06-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2019 (June 30, 2O2) Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division c- SYSTEM SENSOR Output Horns, Horns, Strobes, and CHornStIObesforJ.1 v.aIIAppIications_ System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only Agency Listings SIGNAUNG LISTED APPROVED S5512 FM approved except 7135-1853:0504 S4011 to, ALERT models 7135-1653:0503 3051383,3057072 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobe.s, and horn strobes in the iridustrj with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strooes, and horn strobes include a variety of features that -ncrease :rieir application versatility while simplifying installation. All devices feature plug-in desgns with minimal intrusion into the bank box, making installations fast and foolproof while virtually elimhating costly and time-consuming ground faults. To further simplify installation and protect devices from construction Carnage, the L-Series utilizes a universal mounting plate for all nodels with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a su t a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95,110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1•2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal) or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91 "D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm x 49 mm D) Horn Dimensions 5.6"L x 4.7W x 1.25"D (143 mm Lx 119 mm x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D (133mm Lx 88mm W x 32mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15-115 Cd) 8-175 Volts (C643_Vk(W 115cd 30cd 15cd 30cd 75cd 95cd 135cd 185cd 98 158 54 74 121 142 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes L-Series Dimensions 1.91 -3.46 —a 5.27 Compact Strobe I Horn Strobe 3.46 ___________ .27 1.25 Compact Horn 4.70 5.67 1.91 1.25 r Strobe! Horn Strobe Horn L-Series Ordering Information irrriModel Description I1MiItII11i1u.1i c*oiistie' Horns (P2RL 2-WiréHorn Stróbe,:Red) HRL Horn, Red P2WL 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe, White HGWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SRL Strobe, Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All-P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have ALERT" marking on cover 5 3825 Ohio Avenue s St, Charles, IL 60174 O2O17 System Sensor. fcunent product intrornatlon, Including the latest version at this data sheet SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 specthcatans subiect tochaflgewithc'Jt notice. Veit systemsensor.com www.systemsensor.com AVDS86503 • 017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM t9 LISTING No. I3b-0653:050) Page 1 of 2 CATEGORY: 135UDI6LEDEIIcES) LISTEE: LS Unirco.ijbráted Div .& èTfrTIi3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennett©honeywell.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; 2RL.P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *p4Jj !aUHbe) PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *1R2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 doe This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2019 (June 30, 2O Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI2OKL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed (j the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division Honeywell DSILENT KNIGHT 15495) Distributed Power Modu1e ,the 5495 Distributed Power Module is the most powerful and cost- effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, and Wheelock. The 5495's switch mode power supply design is up to 50% more efficient than competitive Linear mode power supplies. Also, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery. The 5495 is the costeffective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. CONNECTION TO LOCAL FIRE CONTROL The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kQ end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. FEATURES & BENEFITS UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24V0C filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/ indicator Independent trouble relay AC loss delay option shuts off power to non-essentiaL high-current accessories like magnetic door holders Built-in synchronization for appliances from System Sensor', Gentex, AMSECO, and Wheelock Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in 5495 Technical Specifications Model 5495 Block Diagram Signal Circuit Output Signal I Signal I Input tributed Signal 2 Signal Circuit Output Signal 2 Input DIs Power Signal 3 (Optional) Module 5495 Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (A1t.rnative to notification circuit trouble.) SUPERVISION mperutput cfriiiE3.O (6.0 amps total)) The 5495 supervises a variety of functions Notification circuit output: Alarm Current (for including: typical voltages) drawn from main panel's Low AC power notification appliance circuits. 12 VDC 6.5 mA Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 stilt maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. PHYSICAL Dimensions: 12.25Wx 16"H x 3"D (30.88 cm W 40.64 cm H x 7.62 cm D) 24 VDC One input circuit: 15 mA; Both input circuits: 0 mA No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9- 32V0C INDICATOR LIGHTS AC power on: Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow ORDERING INFORMATION Fora complete listing of all compliance approvals and certifications, please Visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensors and Honeywell" are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support. call 800-446-644. ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10% - 93% non-condensing) ELEcTflucM AC Input: 120 VAC at 2A tZ4.VDit 6A CCurSd75mAAlarm 205rnA Auxiliary power circuit: 1 Notification circuits: 4 Output configuration:2 Class A (Style Z): 4 Class B (Style Y) (1 Class A&2 Class B) ACCESSORIES SK-SCK: Seismic Compliance Kit AGENCY LISTINGS UL listed CSFM 7300-0559:123 Meets NFPA 72 requirements MEA429-92-EVolXiI OSHPD (CA) OSP-0065-10 For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 3503951 Rev HI 11/17 © 2017 Honeywell International Inc. Honeywell DSILENT' KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of I CATEGORY: LISTEE: Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN Models 5395 495 nd *54ggIDIsfribed Power Module (Indicating Circuit panderJUnit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two I2VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and I auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Rec 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listingge Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NP/NPX SERIES 111111 SEALED RECHARGEABLE LEAD-ACID BATTERIES YUASA (/N PX IN DUSTRIALBATTERIES PINK brand NP and NPX batteries give excellent performance in either float or cyclic applications. These batteries are designed for tight duty cyclic applications, fire and security systems. Emergency lighting, solar and wind support systems. UPS systems and toys! / POWERING THE NEXT GENERATION CGSYUASA T NP/NPX SERIES YUASA SEALED RECHARGEABLE LEAD-ACID BATTERIES The Yuasa brand of small valve-regulated batteries have, since their introduction, set the standard for quality and excellence in the field of rechargeable sealed Lead-acid battery technology. This standard has been used as a benchmark in applications such as security, uninterruptible power supplies (UPS), emergency Lights and medical equipment. Anywhere the need for reliable and dependable back-up power is required, Yuasa sets the pace. The Yuasa brand NP product Line covers the entire spectrum of battery sizes, ranging from 1.2 Ah to 65Ah in 6 and 12 volt varieties. Yuasa also offers a full Line of flame retardant batteries (UL94-VO, LOI 30). Designated "FR". these batteries comply with UL1778 flame retardant specifications for UPS. Yuasa also offers the NPX Series Batteries, designed for high rate discharge applications. These batteries are used primarily where high wattage is required for a short duration. With 50% more wattage available and a 30% reduction in size over conventional batteries, the NPX Series offers a superior value, especially in UPS applications. AM"NSAP BEThtN CHA%OsNc3 V0LTAG AND Tt&iPflATtrM IarI— - - . 1 - 1 It, V 0a Is 40 4!Ifi 10 U II 10 133 10.11 .%uIaNT TIMPI!MVIU ME fieft%*409- NREWIO$TOPTH ORNPSRI tttG CTh1OS LH1.74AI0) LYovitia HAGtN - n4AIMOM LFMMIAR CUY OAM U - i 0* imier itt 40 I)) 00 1:00 14id NUMRLR (IF CYCUS FLOAT SIWICELW NP 69M tttOt1rbft1tP* tØ,t1LL Irn.Nl T[tr'crH*14 LRE(YtMt) -1—i / CGSYUASA GS Yuasa Energy Solutions, Inc. 2 AIR AND 'PAM SERIES in Control MULTI-VOLTAGE RELAY MODULES'. The PAM Series Relays are encapsulated multi-voltage devices with "flying" leads that offer versatile, reliable perfor- mance in a convenient package. Several of the versions contain a red LED which indicates when the relay coil is energized. The PAM Series Relays are packaged with a self-tapping screw and a piece of double sided tape for easy installation almost anywhere. The relays are also packaged with wire-nuts to aid installation. PAM Relays are ideal for applications where remote relays are required for control or status feedback They are suitable for use with HVAC,Temperature Control, Fire Alarm, Security, Energy Management, Lighting Control Systems and Building Automation Systems. PRODUCT DESCRIPTION PAW The PAM-I Relay provides 10.0 A form "C" contacts. The relay may be energized by one of three input voltages: 24VDC, 24VAC, or I 2OVAC. The input voltages are polarity-sensitive and diode-protected. PAM-I Relays contain a red LED which indicates when the relay coil is energized. 'AM-2' The PAM-2 Relay provides 7.0 A form "C" contacts. The relay may be energized by one of two input voltages: I 2VDC or 24VDC. The input voltages are polarity-sensitive and diode-protected. PAM-2 Relays contain a red LED which indicates when the relay coil is energized. PAM-4 The PAM-4 Relay provides 10.0 A form "C" contacts. The relay may be energized across a wide voltage range from I 2VDC to 40VDC, making it ideal for I 2VDC and 24VDC EOL circuits. The 20mA operating current is constant across the operating range. The input voltages are polarity-sensitive and diode-protected. PAM-SD The PAM-SD Relay provides 7.0 A form "C" contacts. The relay may be energized by an input voltage between 20VDC to 32VDC, making it ideal for 24VDC NAC circuits. The input voltages are polarity-sensitive and diode- protected. The PAM-SD provides an additional set of wires for redundant input voltage (circuit supervision pass through). c® us CSFM LISTED MEA ACCEPTED LISTED Air Products and Controls is a Brand of Apollo America ____A 25 Corporate Drive Auburn Hills, Ml 48326 HALMA (248) 332-3900 Phone GROUP (888) 332-2241 Toll free COMPANY (248) 332-8807 Fax www.ap-c.com Distributed WIRING A - RELAY ENERGIZED LED BLU \ ______ ORG O)CONTACTS H: X'NC I 10.OA 120 VAC @ 50mA - 24VAC @ 50mA 24V0C @ 20mA PAM-1 I2VDC /(+)_RED M YEL c TO4OVDC NC IOOA _____NO) NTACTS @ I BLK PAM-4 WHT RELAY ENERGIZED LED SLU øv(-) YE 7.OA +24VDC t 20mA NC +I2VDC t 20mA RED _____ ORG NO) CONTACTS PAM-2 @15mA (-) J,X!LNC 7.0 A 2OVDC ((_) TO _____ CONTACTS 32VDC () t 25mA RED ORG NO PAM-SD PRODUCT SPECIFICATIONS MUL)LNUMbb.F<: IAM-1 .rAM- rAlvl-4 rAIvI-DLS COIL VOLTAGE: 24VAC/24VDC/I20VAC I2VDC/24VDC 12 to 40VDC 20 to 32VDC POLARIZED: Yes Yes Yes Yes - ENERGIZED LED INDICATOR Yes Yes No No CURRENT REQUIREMENT: 12VDC c24VDC 032VDC @24VAC @I20VAC 20mA 20mA 20mA 20mA 20mA 15mA 20mA 25mA 50mA 50mA CONTACT CONFIGURATION: (1) SPDT dry form "C" (1) SPDT dry form "C" (1) SPDT dry form "C" (1) SPOT dry form "C" CONTACT RATINGS: (contact rating/ power factor) @5VDC @24VDC @120VAC 250pA /.35PF 250pA /.35PF 250pA 250pA!.35PF 7A/.35PF 7A/.35PF 7A 7A!.35PF 10A 7A/.35PF IOA 7A/.35PF RELAY PULL-IN TIME: @24VDC @24VAC @120VAC @12VDC <is <5s <Is <is <3s <is @32VDC <1.5s <Is <is <Is WIRE LEADS: 6 "flying" leads 12"!I8AWG Wire-nuts provided 6 "flying" leads 12"/I8AWG Wire-nuts provided 5 "flying" leads 12"/I8AWG Wire-nuts provided 7 "flying" leads 12°/I8AWG Wire-nuts provided AMBIENT TEMPERATURE: (@100%_RH,condensing) 32°F to 120°F (0°C to 49°C) 32°F to 120°F (0°C to 49°C) 32°F to 120°F (0°C to 49°C) 32°F to 120°F (0-C to 49°C) CONSTRUCTION: 100%potted(sealed) with "flying"leads MOUNTING: Pre-drilled mounting screw holeandself tapping screw provided.Doublesidedtapeprovided. DIMENSIONS: H W D 1.50°(38mm) 1.50"(38mm) 1.50"(38mm) 1.50"(38mm) 1.20"(31mm) 1.20°(31mm) 1.20"(31mm) 1.20"(31mm) 0.77"(20mm) 0.77(20mm) 0.77"(20mm) 0.77(20mm) LISTINGS AND APPROVALS: UL": MEA: 'CSFM: UOXX/7.S3403 UOXX/7.S3403 UOXX/7.S3403 UOXX/7.S3403 73-92-E Vol.21 1 73-92-E Vol. 21 1 73-92-E Vol.21 1 73-92-E Vol.21 7300-1004:101 1 7300-1004:101 1 7300-1004:101 1 7300-1004:101 °UOXX=Control Unit Accessories, System; !7=also Certified for Canada NOTICE: The information contained in this document Is intended only as a summary and is subject to change without notice. The products described have specific instructionatilnstallstion documentation, which covers venous technical, approval, code, limitation and liability information. Copies of this documentation along with any general product warning and limitation documents, which also contain Important information, are provided with the product and are also available from Apollo Amnenca Inc. The information contained in all of these documents should be considered before specifying or using the products. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning the products, contact Apollo America Inc. Apollo America Inc. reserves the right to change any and all documentation without notice. ©Apollo America Inc. 2016 DS-RL-1 F161104 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (9 LISTING No. 7300-I004:0101 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC DEVICE LISTEE: Apollo America lnc.25Corporate Dr., Auburn Hills, MI 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MR..IOI/C/R *MR..1..S5E/C *MR101SSE/C/R, MR-104/C, *MR104/C/R, *MRI 04-SSE/C, *MR..104..SSEIC/R MR-201/C, MR-201/CrR, *MR..201..SSE/C *MR..201..SsE/C/R MR-2041C, MR204/C/*R, *MR..204.SSE/C *MR..204..SSE/C/R PAM-1,'-2,PAM-3, PAM-4, PAM-SD, RlC-1, RIC-2, RIC-3, RIC-4, MR-RIC-301 rC, *MRRIC..301/C/R MR-RIC-305/C, * MR-RIC-305/C/R, MR-RIC-401 */C *MR..RIC..401/C/R MRRlC405*/C and *MR..RIC..405/CIR'relay modules *Models MR-ITMIC and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: I. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing Epire. (June 30, 2020" Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Faster installation with more precise response to alarms Each detector reports alarms back to the panel with its address. Reduced wiring speeds installation time Emergency responders know where to go first Trouble alerts to a specific detector Addressable conventional smoke detector Built-in single zone Addressable module for OMP LX-Bus connection The 2W1-BLX also includes an integrated heat sensor Red LED blinks once every five seconds to indicate maintenance required AND 2WT-BLX a SYSTEM FEATURES AddessabLe singpoint detectoiiödulé Fixed-temperature thermal detector trips at 135°F Built-in drift compensation ensures reliable sensing LED lights speed installation and confirm status State-of-the-art optical sensing chamber Easy rotary switch addressing Proven design ensures stability and performance IWGLE-POINT ADDRESSABLE TECHNOLOGY A factory-mounted, addressable single- point zone expander is integrated into the base of the smoke detector. Because each detector reports individually to the panel, trouble reports are identified to a specific detector, speeding repair. No need to replace the heads on a string of detectors or individually test each detector to pinpoint the source of the problem. In an alarm situation, facility owners and first responders instantly know the exact location of the alarm, enabling a faster response. For any installation that includes multiple rooms or areas, addressable technology offers many benefits. SIMPLIFIED TROUBLESHOOTING Addressable detectors provide trouble signals traceable back to a separate detector. This further simplifies troubleshooting and speeds repairs. FIXED TEMPERATURE THERMAL DETECTOR The 2WT-BLX features a restorable, built-in, fixed temperature thermal detector and is capable of sensing a temperature higher than 135°F condition. If the detector senses a higher temperature than 135°F. the Red LED latches on and an alarm condition is sent to the control panel. BUILT-IN DRIFT COMPENSATION As detectors age and accumulate contaminants or as their environment changes, false alarms become more common. With drift compensation, the detector automatically adjusts to maintain the UL-acceptable operating range. Smoothing algorithms compensate for these changes, reducing nuisance alarms. LED STATUS LIGHTS Wide-angle. dual-color LEDs provide at- a-glance status indications. After power- up has completed and the detector is functioning normally, the green LED blinks once every five seconds. If the detector needs maintenance because its sensitivity has shifted outside the limits, the red LED blinks once every five seconds. GREEN LED RED LED Power-up Blinks 10 seconds Blinks 10 seconds Normal (Standby) Blinks 5 seconds Out of sensitivity -- Blinks 5 seconds Alarm -- Solid COMMUNICATION VERIFICATION The verification feature speeds installation and ensures system integrity by verifying the wiring and confirming device polling using a 2-second flashing green LED on the integrated zone expander. SIMPLIFIED WIRING Compared to non-addressable devices, addressable detectors require much simpler wiring. This type of wiring reduces both installation time and the chance of errors. MOUNTING OPTIONS Multiple options provide installation flexibility. Each detector is supplied with a mounting base that can be mounted: To a single gang box To a 336- or 4-inch octagonal box To a 4-inch square box with plaster ring Directly to the ceiling using drywall fasteners The bases can be pre-wired so the heads can be quickly inserted to complete the installation. TAMPER RESISTANT The detectors include a tamper-resistant feature that prevents removal from the mounting base without the use of a tool. EASY ADDRESSING Setting the address is as easy as rotating the two on-board rotary switches to positions matching the LX-Bus zone number address. (SPECIFICATIONS) 0 pier—ati ffg Voltage 12 VDC Dimensions 5.3" Dia. x 2.0" Weigh 6.3 ounces afldbyC_ uffent JjR Maximum Ripple 30% (V) peak to peak Operating Temperature (Ambient Room) 2W-BLX 32°F to 120°F 2W'F-BLX 32°F to 100°F Humidity Range 0 to 95% RH non-condensing Heat Sensor 135°F (2WT-BLX Only) Power-Up Time 45 seconds Photoelectric Sensitivity 2.5%/ft. max. ORDERING INFORMATION (W-BLX/10 [Photoelectric smoke deèt) 2WT-BLX/10 Photoelectric smoke detector with fixed-temperature thermal detector LISTINGS & APPROVALS California State Fire Marshal (CSFM) Underwriters Laboratories (UL) Listed UL 268 Smoke-Automatic Fire Detectors e 0 0 0 0 .4 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM t9 'Q1..' 9-."'00 LISTING No. C7272-1 157O37 Page 1 of I CATEGORY: 2 - SMOkE!DETECTOR-SYSTEM TYPE-PHOTOELECTRIC) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 831-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN pdels 2W BLXand 2W BLXWO wire addressable photoélectricimoke detectors) Model 2W1-BLX employs a supplemental heat sensor for use only to assist the smoke detector. This thermal circuitry is NOT approved for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed a photoelectric smoke detectors for use with listee's separately listed Models XRI 50, XR350, and XR550 (CSFM No. *7165..1157:0134 and 7165-1157:0135 ) or Models XR500, XR500N, XR500E, XRIOO and XRIOON (CSFM No. 7165-1157:0123 and *7165..1157:0127) fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev O6lll4gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division c- SYSTEM $ SENSOR DtK1DLector3 The InnovairFie? Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features 4-Wire Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 mIs to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3/4-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories 1nn0VC,1fl11'_r&W The InnovairFIex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The InnovairFiex housing provides ample wiring space, a 34-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 IrirtovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFiex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new AgencylListings) InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. <8> WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; LISTED APPROVED NOT a replacement for a building's regular fire detection system. 2911 3033744 3242-1653:0207 Refer to NFPA 72 and 90A for additional information. lnnovairFlexTM Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex êDftrThe detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch test button on the cover, or remote testing using the RTS2-AOS Multi-Signaling Accessory or the RTS151 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: (Rectangular Dimensions) 14.38 in (37 cm) Length: 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19.7 cm) Length: 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature Range: D4120 & D4S: -4° to 158°F (-200 to 700C); D4P120: -400 to 158°F (-40° to 70°C) Storage Temperature Range: D4120 & D4S: -220 to 158°F (-30° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 20.32 m/sec) Electrical Ratings Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 pF max. 270 pF max. N/A Reset voltage: 3.0 VDC mm. 2.0 VAC mm. 10 VAC mm. Reset time: (with RTS151) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 35 sec. max. 35 sec. max. 35 sec. max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Alarm Initiation contacts: 2.OA © 30 VDC (resistive) (SPST) Alarm auxiliary contacts: 10A @30 VDC (resistive); 10A © 250 VAC (resistive): ½ HP © 240 VAC; ¼ HP @ 120 VAC (DPDT) Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPDT) 2.OA © 30 VDC (resistive); 2.OA © 125 VAC (resistive) Accessory Current Loads at 24 VDC Device Standby Trouble Alarm APA151 12.5 mA n/a 30mAMax. MHR/MHW -- 0 mA n/a 29 mA Max. - RA100Z 0 mA n/a 12 mA Max. RTS151/RTS151KEY 0mN12mA n/a 12mAMax. RTSRTS2-AOS 3.0mA max 16 mA Max. with strobe: 55 mA max: without strobe 30 mA max Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFiex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be Wiring for 4-wire Duct Smoke Detector and Accessories I POWER INPUTS (NOTE 1) I I 4VACJDQ 120 I VVAC1 I I 910 I I OR I I AUXILIARY CONTACTS I I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB SUPERVISORY CONTACTS I (NOTE 3) I I POWER INPUTS (NOTE 1) I I r4n 910 I OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB Ij7j7I I SUPERVISORY CONTACTS I I (NOTE 3) I EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER '1 ------------- FIRST DETECTOR IN THE LOOP NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or 24VAC 50-601-1z. 120VAC Power Inputs accept only 120VAC 50-601-1z. Connect power source to appropriate terminals of each detector. See specifications for additional power supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. *Please refer to the corresponding installation manual for accessory wiring diagrams. ------------- LAST DETECTOR IN THE LOOP NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. Important Notes on 2:1 Sensor-to-Power CaDabili 2:1 sensor-to-power capability is not available for all InnovairFiex models. The feature is only available on the D4120 4-wire conventional models. 2:1 sensor-to-power capability can be enabled using one D4120 and one D4S, or two D4S and one D4P120. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 t the INT+ terminal on unit 2 and so on. Similarly, connect the INT/AUX- terminal on unit 1 t the lNT/AUX- terminal on unit 2 and so on. Up to 5004120 units, 50 04P120 units, or 50 units of combination may be interconnected. Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected may be replaced by three D4P120 units. Therefore, when using the interconnect feature a single DH100ACDC can drive either 9 DH100ACDCs or 27 04120 units. * NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. RTS151 ULS4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 H11 WXNW- MHWULS4011 RA100Z UL S2522 MHRULS4O11 AOS Ordering Information Accessories D4S 4-wire photoelectric sensor component only D4P120 4-wire photoelectric power board component only, 24 VAC/DC, 120 VAC 2D51 4-wire conventional photoelectric sensor head DST1 Metal sampling tube duct width up to 1 f (0.3m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2m) DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST10 Metal sampling tube duct widths 8 f to 12 ft (2.4 to 3.7 m) APA151 Remote annunciator with piezo alarm ETX Metal exhaust tube duct width 1 f (0.3m) M02-04-00 Test magnet MHR Mini Horn, Red MHW Mini Horn, White P48-21-00 End cap for metal sampling tubes RA1 OOZ Remote annunciator alarm LED RTS151 Remote test station RTS151 KEY Remote test station with key lock RTS2 - AOS Multi-signaling accessory with add on strobe cYTEf/1 3825 Ohio Avenue • St. Charles, IL 60174 eo13 System Sensor. Icr current product information, Including the latest version of this data sheel SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 uclsplicafcnssobIeCtlachangeV4llto5tsoUcetsYSterrrsensoccn1 www.systemsensor.com HVDSOO502 • 10/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. @242.1653:0207 Page 1 of I CATEGORY: (2— bUCT MOKE.DETECTOR PHbTO(VWORW1OBASE)J LISTEE: Lsystem_SerisorUniñcorporated Di H6 6b Inc 825 Ohio Ave, St Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: [M6d6li04120]D4240, RD4120, P270-3000PL, TD41203, TD41204, LD4S, LD4I20X, LD4I20H, 134S, 13413120, CD4PI20 LD4PI20X, LD4PI20H, TD4C, PD4120, YD4120, YD413I20 and AD4P120ur wire conven ifieIectric duct smoke detectors and] ubáséhiii Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 21351 detector head (CSFM Listing No. 7272-1653:203). Model AD4S sensor component. Models *TD4C, LD4I2OX, LD4I20H, LD4PI20X and LD4PI20H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC, *24 VAC, 120 VAC (except Models *TD4C, LD4I2OX, LD4I20H, LD4PI20X and LD4PI20H *do not have 120 VAC rating). a INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-27-13 gt a This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I a ;Fire Alarm Systems' Fire Power Limited,' ccwlRI'riiCT$wiw JUser) Product Description Multi conductor msulated wire twisted for maximum flexibility and jacketed with a fire retardant PVC. FPLR,CL2R UL Standard 1424 Fifth Edition February 16, 2007 Meets NEC Article 760 & California Fire Marshall Requirements. Conforms to UL 1666 Flame rating Application: Riser Rated Non Shielded Fire Detection Signaling *450422R 450622R 22 22 4 6 .006 .006 .014 014 .117 .144 16 16 17 25 450218R 2 .006, 014 (i4 2i 40 450418R' '18 r4r '006 014 165 121 450618R 18 6 .006 014 .195 21 50 450216R 16 2 .008 014 .155 23 30 450416R 16 4 .008 014 .181 23 50 450214R' 14 '.008 .i84 7, 46k 450414R 14 4 .008 014 .215 27 70 450212R 12 2 .008 014 .215 27 55 These values are nominal in accordance with industry standards. Additional gauges, colors or stranding are available upon request with minimum purchase orders. Color Code Chart 3 *Special Color Code - Blk-Red-Yel-Gm Available in 500 or 1000' Standard Jacket Color - Red Boxes, Spools or Coil Packs Voltage - 300V Max Temperature —20° to 60°C FALCON FINE WIRE, AND WIRE PRODUCTS, INC. 2401 DISCOVERY BLVD • ROCKWALL, TEXAS 75032 214-771-3441 • 972-722-9168 • falconwire@aol.com rX i.. lHJ3flV CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL OU 0 LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (9 LISTING No. 7161-1358:0100 Page 1 of I CATEGORY: 7161 - CABLES-FIRE PROTECTIVE SIGNALING LISTEE: TALCON FINE W1RE240I Discovery Blvd, Rockwall, TX 75032 Contact: Wiliam LeCount (214) 771-3441 Fax (972) 722-9168 Email: falconwire@aol.com DESIGN: Types FPL, FPLP and *FPLR power limited fire alarm cables. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Articl 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type FPL, FPLP or FPLR and UL label. APPROVAL: Listed as a power-limited fire protective signaling cable. a Rev. 05-04-11 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires, June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division