2882 WHIPTAIL LOOP; 150; FPC2019-0028; Permit
PERMIT REPORT (ity of Carlsbad Print Date: 02/29/2024 Job Address: 2882 WHIPTAIL LOOP, # 150, Permit Type: FIRE-Construction Commercial Parcel #: 2091200700 Valuation: $589,188.68 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: CARLSBAD, CA 92010-6708 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2O19-0028 Status: Closed - Finaled Applied: 02/14/2019 Issued: 02/25/2019 Finaled Close Out: 02/25/2020 Final Inspection: INSPECTOR: Fieri, Dominic Project Title: Description: VECTOR 2 -SPRINKLER MONITORING TI Applicant: FPContractor: CHULA VISTA ALARM INC CHULA VISTA ALARM INC JAMES RODRIGUEZ 6175 PROGRESSIVE AVE, # STE 400 1105 CLOUDWALK CANYON DR SAN DIEGO, CA 92154-6649 CHULA VISTA, CA 91911-6835 (619) 585-9111 (619) 585-9111 FEE AMOUNT FIRE TI Fire Alarm System -- $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 - Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov FIRE ALARM SYSTEM SUBMITTAL SPEC SUITE 150 2882 WHIPTAIL LOOP E. SUITE 150 CARLSBAD,CA 92010 FUEGO ENGINEERING & DESIGN INC PREPARED FOR: CHULA VISTA ALARM INC P.O. BOX 212731 6175 PROGRESSIVE AVE. SUITE 400 CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 CELL: (619) 610-8637 PHONE: 619-585-9111 OFFICE: (619)796-3360 PRO3ECT SPEC SUITE 150 2882 WHIPTAIL LOOP E. SUITE 150 CARLSBAD,CA 92010 Model Number Description CSFM# MS-9600UDLS FIRE LIFE FIRE CONTROL PANEL (EXISTING) 7165-0075:0217 FCPS-24FS6 BOOSTER POWER SUPPLY (EXISTING) 7135-0075:0206 BG-12LX FIRE LITE ADDRESSABLE PULLSTATION 7150-0075:0184 MMF-300 FIRE LITE ADDRESSABLE DUAL MONITOR MODULE 7300-0075:0185 CRF-300 FIRE LITE ADDRESSABLE RELAY MODULE 7300-0075:0185 RTSI5I KEY SYSTEM SENSOR REMOTE TEST/RESET STATION 7300-1653:0212 P2WL SYSTEM SENSOR WALL HORN-STROBE 7125-1653:0503 FUEGO ENGINEERING & DESIGN INC PREPARED FOR: CHULA VISTA ALARM INC P.O. BOX 212731 6175 PROGRESSIVE AVE. SUITE 400 CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 CELL: (619)610-8637 PHONE: 619-585-9111 OFFICE: (619)796-3360 df-60334:A4 • Al -100 MS.9600LS( E)IMS.9600UDLS( E) Intelligent Addressable FACP with Optional 2nd Loop 8 Fire LIT'ALS by Honeywell General FirelJte's MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Con- trol Panels) with an extensive list of powerful features. The combination of FlrrLite's newer series devices and legacy 300 Series devices, along with the MS-9600L.S(E) or MS-9600UDLSE FACP, offer the latest in fire protection tech- nology. LiteSpeedTM is a patented technology that polls 10 devices at a time looking for new or different Information. When new information Is found at a specific address, the sys- tem polls that device several times for any new data. This Improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification cir- cults In under 10 seconds. With this new polling scheme, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Cir- cuit (SLC) loop supports up to 159 addressable detectors Including photoelectric, photoelectric with heat, beam, ioniza- tion, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules Including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules. The FLPS-7 power supply is a separate board while all other electronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabinet. The backbox can be installed allowing field Wring to be pulled. When construction is completed, the chas- sis with the electronics can be quickly installed with two bolts. The MS-9600UDLS(E) includes a factory-installed DACT-UD2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Sta- tion via Internet (optional IPDACT installed) or the public switched telephone network. Optional modules, which plug into the main circuit board, are available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download soft- ware and remote power expansion. MEMBRANE SWITCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 12-key pad with full alphabet 4 cursor keys ENTER Special Features Easy mount chassis. 7amp switching power supply. Large enclosure allows 18 amp-hour batteries DACT-UD2 plug-in communicator standard with MS-9600UDLS/E. Optional IPDACT Internet Protocol Digital Alarm CommunicatorITransmittr FM APPROVED to UL ANSI 864. _> Four Style V (Class B) or two Style Z (Class A) NAC circuits. Controls And Indicators LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE/PRESIGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) Selectable strobe synchronization per NAC for System Sensor, Wheelock, and Gentex devices. Automated control of ACC-25/50(ZSFr) audio speaker cir- cuits ANN-BUS for connection to following optional modules Note: cannot be used if ACS annunciators are used. ANN-80(-W) Remote LCD Annunciator ANN-I/O LED Driver Module ANN-S/PG Serial/Parallel Printer Module ANN-RLY Relay Module ANN-LED Annunciator Module ANN-RLED AnnuncIator Module (alarms only) df-60334;A4 • 12129/2009 - Page 1 016 Standard Features SLC LOOP SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 318 addressable devices per loop (159 detectors and 159 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,048 m) 0 12 AWG (3.1 mm2) using twisted, unshielded wire (see Wire Table on page 5). NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to two Class A NACs with the NACKEY (Included). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 3.0 amps maximum per each NAC circuit Note: Maximum 24 VDC system power output Is shared among all NAC circuits and 24 VDC special appilcation aux- iliary power outputs. Total available output is 7.0 amps. ADVANCED FIRE TECHNOLOGY: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local PS/2 keyboard or PC (using the standard PS-TOOLS Windows® utility). Two-level user-programmable passwords. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. USER INTERFACE: Optional plug-in DACT-UD2 communicator (standard with MS-9600UDLS(E) with USB port for local upload/download. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules, ACS Series annunciators, LCD-80F remote annunciator, or ANN-80 Series Annunciators. EIA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. History file with 1,000-event capacity. ElA-485/ANN-BUS supporting up to 8 ANN Series Annunci- ators or 32 ACS Series annunciators. ElA-485 supporting up to 32 ACS annunciators. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Local piezo sounder. Waterfiow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). Optional 4XTMF module (conventional reverse polarity/city box transmitter). Field-programming Features Ott-lIne Programming: Create the entire program in your office using a Windows®-based software package (order pro- gramming kit PK-CD, containing PS-TOOLS, separately). Upload/download system programming locally to the MS-9600L5/E in less than one minute. Autoprogramming: Command the MS-9600L5(E) to program Itself (takes less than 30 seconds). In the Auto-Program mode, the MS-9600LS(E) scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. Online Editing; While still providing fire protection, the MS-9600LSIE may be programmed from the front panel. Sim- ple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming manual. English Label Library: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as ¶LR 3 HALLWAY," or enter custom labels letter-by-letter. Use recall function to repeat previously used label. Program Check: Automatically catch common errors, such as control modules not linked to any zone or Input point. Maintenance Alert The MS-9600L5(E) continuously monitors each smoke detec- tor and is capable of reporting maintenance conditions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more informa- tion. Automatic Test Operation The MS-9600LS(E) performs an automatic test of each detec- tor every two hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trou- ble. Terminal Blocks AC Power - TB1: 120 VAC, 60 Hz, 3.0 amps or 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery (lead acid only) - T82: Maximum charging circuit: Normal fiat charge 27.6 VDC 0 1.0 amp. Maximum battery charger capacity: 26 AH. Minimum battery 12 AH. MS- 9600L5(E) cabinet holds maximum of two 18 AH batteries. For 26— 120 AH batteries, use the CHG-120F or CHG-75 Battery Charger and BB-55F Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to disable the FACP battery charger when using the CHG-120F or CHG-75. Communication Loop - (standard) TBB: 24 VDC nominal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, unshielded pair length. Maximum loop current: 400 mA (short circuit) or 100 mA (normal). Maximum loop resistance: 40 ohms. Supervised and power-limited. Notification Appliance Circuits - T04: Power-limited cir- cuitry. Nominal operating voltage: 24 VDC. Current limit: fuse- less, electronic, power-limited circuitry. Maximum signaling current per circuit: 3.0 amps. End-of-Une Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for NACs. Refer to Fire•Lite Device Compatibility Document for listed compatible devices. Page 2016— dt-60334:M • 12129009 Programmable and Trouble Output Relays - TB5: Contact rating: 2.0 amps 0 30 VDC (resistive). 0.5 amps 0 30 VAC (resistive). Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - TB3, Terminals 1(+) & 2(—): Maximum ripple voltage: 10 mVRMS. Up to 1.5 amps for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to Fire•Lite Device Compatibility Document for listed compatible devices. Nonresettable Power #1(24 VDC Nominal) —TB3, Termi- nals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVAM8. Up to 1.5 amps total DC current available from each output. Power- limited circuit. TBS, Terminals 5 (+) & 6 (-): non-resettable power #2. Nonresettabie Special Application Power #2(24 VDC Nom- inal) - TBS, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10mVRMS. Total DC current available from each output is up to 1.5 amps. Power-limited circuit, nonsupervlsed. EIA485 (ACS!ANN) - TBS-. Annunciator connector, program- mable for type ANN or ACS. Terminal 1 (+) and Terminal 2 (-). ElA485 (TERM) - TB?: Terminal mode annunciator connec- tor, Terminal 1 (Out +), 2 (In +), 3 (Out—), 4 (In -). EIA-232 - TBB: PC4rinter connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground). Ordering Options MS-9600L5(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display; sin- gle printed circuit board, and cabinet. MS-9600UDL.S(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes DACT-UD2, 80-character LCD display, single printed circuit board, and cabinet. DACT-1.102: Optional communicator for remote monitoring (standard with MS-9600UDLS). 4XTMF: Optional Transmitter Module provides a supervised output for local energy municipal box transmitter, alarm and trouble reverse polarity; it includes a disable switch and dis- able trouble. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (P/N: IPBRKT). Connects to primary and secondary DACT tele- phone output ports for Internet communications over customer provided ethernet Internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for addi- tional information. IPBRKT: Optional mounting bracket kit consisting of screws and battery shield with standoffs required when mounting the IPDACT In lower enclosure section of FACP. IPSPLT: Optional V- Adaptor which allows connection of both panel dialer outputs to one cable input to IPDACT (sold sepa- rately). ACM-8RF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PK-CD: Contains PS-TOOLS programming software for Win- dows®based PC computer (cable not Included). SLC-2L8: Optional expander module, enables second SLC loop. DP-9692: Optional dress panel for MS-9600L5(E). TR-CE: Optional Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two 25 AH batteries and one CHG-120F battery charger. For batteries greater than 25 AH, consult factory for housing/mounting arrangements. BB-26: Battery backbox, holds up to two 25 AH batteries. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 25 to 120 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. CFlG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. BAT Series: Batteries, see data sheet DF-52397. PRT!PK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer which uses tractor- fed paper. Compatible Addressable Devices All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. S0355: Addressable low-profile photoelectric smoke detector. S0355T: Addressable low-profile photoelectric smoke detector with thermal sensor. 11355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355H1: Fast-response, low-profile heat detector that acti- vates at190° F (88°C). A0355: Low-profile, intelligent, 'Adapt" multi-sensor detector; B35OLP base included. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D350PL: Photoelectric low-flow duct smoke detector. D35ORPL; Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts In standard 4.0° (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF400: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only iDCs. MMF-301: Miniature version of MME-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CMF4100: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0' (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300; Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0° (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with Interface mod- ule mounted inside. 1300: This module Isolates the SLC loop from short circuit con- ditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. 0410334:A4 • 12/29i2009 - Page of 6 EIA -485 24 VDC INTERFACE (4-data wires, [I 2-power wire Up to 6,000 ft. (1825.8 m) I between each LCD-80F I In the EIA-485 loop, and I between each LCD-80F I and the FACP EIA -485 ACS/ANN-BUS I ANNUNCIATORS I (2-data wires. 2-power wires) t11.] ANN-SO EIA -232 INTERFACE ~~* 4--1 PRINTER Optional REVERSE POLARI1Yl CITY BOX OUTPUT (4XTMF) IIji 4XTMF Reverse Polarity Module Audio Control for ACC-25150(ZSIT) Audio-Command-Center I, DACT.UD2I for Central Station reporting (see photo detail below) SMOKE DETECTORS S0355, 5D3551, CR355 11 111111 S FORM-C, $-AMP RELAYS (optional, order ACM-8RF) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES INTELLIGENT BEAM DETECTORS BEAM355, BEAM355S 00 iI0 MONITOR MMF-300, MDF-300, MMF-302, CMF-300, CRF-300. 1300 * I MINI MONITOR MMF-301 HEAT DETECTORS H355, H355R [ml DUCT DETECTORS D350PL, 035ORPL Page 4016— dt-80334A4 • 12/29/2009 IPDACT Internet Protocol DACT ADDRESSABLE MULTI-MODULES MMF-300-10, MMF-302.6, CMF-300-6, CRF-300-6 LEI PULL STATION BG-121X MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-3024: Six-zone Interface module. Mount one or two modules in a B8-21F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. Compatible Annunciators ANN480(-W): Remote LCD annunciator that mimics the infor- mation displayed on the FACP's LCD display. Recommended wire type Is unshielded. (Basic model is red; order -W version for white; see DF-52417). ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points (see DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays (see DF- 52431). ANN-SIPG: Serial/Parallel Printer Gateway module provides a connection for a Serial or Parallel printer (see DF-52429). ANN-hO: I/O Driver Module provides connections to a user supplied graphic annunciator (see DF-52430). ACS-LED Zone Series: LED-type tire annunciators capable of providing up to 99 software zones of annunciation. Available In increments of 16 or 32 points to meet a variety of applications. ACS-LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. TERM MODE LCD-801F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. Up to 32 LCD- 80F annunciators may be connected to the EiA-485 terminal mode serial Interface on the MS-9600LS(E) motherboard. NOTE: For more information on Compatible Annunciators for use with the MS-9600LS(E), see the following data sheets (docu- ment numbers) ACM-8RF (DF-51555), ACS/ACM Series (DF- 52378), LDM Series (DF-51384), LCD-80F (DF-52185). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. dt-60334:A4 • 129009 - Page 5016 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits .1 expandable to Intelligent detectors .......................................... 159 per loop Addressable monitor/control modules..............159 per loop Programmable software zones.........................................99 ANN-BUS devices..............................................................8 ACS Annunciators............................................................32 LCD Annunciators............................................................32 Electrical Specifications Primary input power: 120 VAC, 50/60 Hz, 3.0 A. 240 VAC, 50 Hz, 1.5 A. Battery: 27.6 VDC 0 1.0 A (max). Maximum battery charger capacity: 26 AH. Minimum battery: 12 AH. MS-9600L8 cabinet holds maximum of two 18 Al-I batteries. Communication Loop: 24 VDC nominal, supervised and power-limited. Notification Appliance Circuits: terminal block provides con- nections for four Style V (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 3.0 A. End-of-Line Resistor: 4.7 K ohms, watt (P/N 71252 UL listed) for Style V (Class B) NAC. Supervised and power-limited. Refer to panel documentation and Fire-Lite Device Compat- ibility Document for listed compatible devices. Two Programmable Form-C Relays and One Fixed Trouble Form-C Relay: Contact rating: 2.0 A 0 30 VDC (resistive) 0.5 A 0 30 VAC (resistive). Four-wire Resettabte Special Application Power (24 VDC nominal): Up to 15 A for powering four-wire smoke detec- tors. Power-Limited, nonsupervised. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Nonresettable Special Application Power #1 (24VDC nomi- nal) TB3, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mV 5 Total DC current available from each output is up to 1£ A. Power-limited, nonsupervised. Nonresettable Special Application Power #2 (24VDC nomi- nal) TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10 mV s Total DC current available from each output is up to 1.5 A. Power-limited, nonsupervised. NOTE: Although each Special Application power output can deliver 1.5 A individually, the total power output from these circuits cannot exceed 1.5A in standby. The total Alarm output for all Spe- cial Application power and NAC circuits cannot exceed 7A. Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.67' (1.70 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 1665° (42.29 cm.) wide x 5.21' (13.23 cm.) deep. Trim Ring (TR-CE): 22.00' (55.88 cm.) high x 19.65' (49.91 cm.) wide. Shipping Specifications Dimensions: 20.00" (50.80 cm) high, 22.5" (57.15 cm) wide, 8.5" (21.59 cm) deep. Weight- 27.3 lbs (12.38 kg). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F i 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be Installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the MS-9800L5(E) and MS-9600UDLS(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing status. ULC: S624 (MS-9600LSC only; see DF-60438) FM APPROVED: to UL ANSI 864 CSFM: 7170-0075:217 MEA: 87-08-E NFPA Standards The MS-9600LS(E) and MS-9600UDLS(E) control panels comply with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Requires 4XTMF where DACT-UD2 is not accepted.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT (Other Technologles-PSDN) For use with IPDACT. LlteSpeedTv Is a trademark, and FlreLiteSAlanne Is registered trademark of Honeywell International Inc. CQOO9 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. iso e try document Is not intended to be used for installation purposes. to keep our product information up-to-date and accurate. cannot cover all specific applications or anticipate all requirements. ao* L H SYST E MAil specifications are subject to change without notice. Made In the U.S. A. For more information, contact Firetite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Page 6 of 6- di-60334:A4 • 12/2912009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0217 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: viadimir.kireyev@Honeywell.com DESIGN: Models MS-9600LS and MS-9600UDLS addressable fire alarm control units. Suitable for local protective, remote, auxiliary, and central station signaling when used with appropriate optional modules and additional separate listed equipment. The panels provide one signaling line circuit for connection of up to 318 total addressable devices (159 detectors and 159 modules); two Class A or four Class B notification appliance circuits; three form C relays are provided that are default programmed for alarm, trouble, and supervisory relay outputs. The MS-9600UDLS come with the DACT-UD2 factory installed. Refer to listee's data sheet for detailed product description and operational considerations. System components: MS-9600LS, MS-9600UDLS Control Unit SLC-2LS Loop Card DACT-UD2 Digital Alarm Communicator Transmitter Modules 4XTMF Transmitter Module LDM-32F Lamp driver Module ACM-8RF Control Relay Module ANN-RLY Remote Relay ANN-80 , ANN-LED, LCD-80F Remote Annunciator ACM-I6ATF, ACM-32AF Remote Annunciator AEM-I6ATF, AEM-32AF Remote Annunciator ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207) RATING: 120 VAC, 50/60 Hz, 3.0 amps INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and FM label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Also suitable for high-rise applications for use with Model ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207). *Models MS-9600LS and MS-9600UDLS panels are also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM #6911-0075:0226). Refer to manufacturer's Installation Manual for details. These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition and meet the requirements of Rev. 01 -20-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed - , the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0075:0217 Page 2 of 2 UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 2. Combined with 7170-0075:220 *Rev. 01-20-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authoiized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52301:A2 • 0-025 FCPS-24FS6 24 Volt. S Amn Power Sunnlv @Fire-uiwmarms -- - Moneywell Power Supplies/Accessories The Fire-Lite FCPS-24FS6(CIE) is a compact, cost-effec- tive, 6-amp remote power supplies with battery charger. The FCPS-24FS6(C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAG) expansion (to support ADA requirements and NAG synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors. The FFCPS-24FS6(CIE) also contains a battery charger capable of charging up to 7.0 Amp hour batteries. FCPS- 24FS6(CIE) is 1.11C-llsted. NOTE: Unless otherwise specified, the term FCPS-24FS6 used in this document refers to the standard FCPS-24FS6, FCPS- 24FS6C, FCPS-24FS6E Features UL-Usted Notification Appliance Circuit (NAG) synchroniza- tion using System Sensor, Wheelock, or Gentex Com- mander2" appliances. Operates as a "sync-follower" or as a "sync-generator (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAG (NAG expander mode) or jumped perma- nently "ON" (stand-alone mode). Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 module) NAGs (circuits 1 & 3) 6-amp full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp continuous output In stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9-32 VDC. Self-contained In compact, locking cabinet - 1511 x 14.5'W x 2.75"D (cm: 38.1H x 36.83W x 6.985D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24FS6: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24FS6/E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 - 16V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24F: 4.0 A maximum. Total short-term current for all outputs (NAG expander mode): - FCPS-24F: 6.0 A maximum. DF-52301:A2 • 5/17/13 Page 1 o14 Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum current charge: 250 mA. Maximum battery capacity: 7.0 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP noti- fication appliance circuits will activate the FCPS when reverse- polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A. Both resettable and non-reset- table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3 Use addressable control modules to activate the FCPS Instead of activating It through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters). Sync Follower/Generator Note In some installations, it Is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When Installed at the end of a NAC wire run, the FCPS-24FS6 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24FS6 is configured (via DIP switch settings) as a 'sync follower:' the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync Input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24FS6 is configured (via DIP switch settings) as a "sync generator:' the FCPS's sync input terminals are not used. Rather, the FCPS Is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor mode, the sync type (System Sensor, Wheelock, or Gentex) Is selectable via DIP switch settings. Standards and Codes The FCPS-24F56 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Page 2 of 4— DF-52301:A2 • 5/17/13 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2424, S1287 ULC Listed: 82424 CSFM Approved: 7315-0076:176 MEA: 387-94E Ordering Information FCPS-24FS6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24F56 Is ULC-listed. FCPS-24F56E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and Installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR4: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1210: Battery, 12-volt, 7.0 AH (two required). P5-1270: Battery 12-volt, 7.0 AH (two required). 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board. NOTE: All NAC outputs can be converted to Style Z with Style Y NAC or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAC Style Y NAC Style Y NAC Contact Output #4 Output #3 Output #2 Output #1 Output AC Power INPUT/OUTPUT FUNCTIONS are programmable by SWI DIP switch settings 24 VOC Specific Application Power NAC Control Input #2 (from FACP) NAC Control Input #1 (from FACP) Sync Input FCPS Battery Charger Simplified Block Diagram DF-52301:A2 • 5117/13 - Page 3 of 4 C 0 N N — —Tv . I I C C 0 C C U) I + I + I + I + + I I I I I I I I I Oc) fill .5 'd h I rO 0 cr I 000 Cm 00Li I I ifi CO M \Ea Ic.J I LJ —LJ1 0 DDD ID 0 000f e0 Board Layout System Sensor® and FireLite® Alarms are registered trademarks at Honeywell International Inc. 02013 by Honeywell International Inc. All rights reserved Unauthorized use of this document Is strictly prohibited. This document is not intended to be used for Installation purposes. ISO 9001 We try top our product Information up-to-date and accurate. - •—,WTI We cannot cover all specific applications or anticipate all requirements. flIø1f&MMN1IItI All specifications are subject to change without notice. QUALITY SYSTEMS Made ln the U.S.A. For more Information, contact Flre.Llte Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flrellte.com Page 4014— DF-52301:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IN LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315 -- POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett©Honeywell.com DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with Iistee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-08-O5JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed -\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division OF-52013:C • E-100 BG. 12 LX @RreUWALWM Addressable Manual Pull Station by Honeywell Addressable Devices The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Serm-flush mount to a standard single- gang, double-gang, or 4 (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.31131); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braila text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 ox. (272.15 g) Normal operating voltage: 24 VOC. Maximum SLC loop voltage: 28.0 VOC. Maximum SIC loop current: 230 hA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4' (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface back- box. if the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4'. (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the downfactivated position. Once latched, the word "ACTI- VATED (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 - 99andMS-9200UDLS, 1 —50 for MS-9050UD). ArchitecturallEngineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with dearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SBA 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4 (10.16 cm) square electrical box, and shall be installed within DF'52013:C'09/02/2009— Page lot2 the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information RG-12LX: Dual-action addressable pull station. Includes key locking feature. SS-10: Surface backbox; metal. SB-U6: Surface badcbox; plastic. ØG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess Consult factory for latest listing status. UL Listed: Sill MEA: 67-02-E CSFM: 7150-0075:184 FM Approved Patented: U.S. Patent No. 0428,351; 6,380,848; 6,314,772; 6,632,108. Fire-Lite Is a registered trademark ci Honeywell International Inc. ceooe by Honeywell International Inc. AU rights reserved. Unauthorized use of this document Is strictly prohibited. The document Is not Intended to be used for installation purposes. We try to keep our product Information up-to-date and accurate' 1921 We cannot cover all specific applications or anticipate all requirements. All specIfIcatIons are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information, contact Flre'Ute Alarms. Phons. (800) 627-3473, FAX (677) 699-4105. www.11rellte.com Page 2 of 2— DF-52013:10 • 09/02/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (9 LISTING No. 7150-0075:0184 Page 1 of I CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-I2LW, BG-I2WP, BG-I2LWP, BG-12L, BG-I2LX, BG-12LA, BG-I2PS, BG-12LSP, BG-I2SP, BG-I2LR, BG-12LRA, BG-I2LAO, BG-I2LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-I2LPSP, BG-12SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-I0 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct jJ operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAViD CASTILLO, Program Coordinator Fire Engineering Division df-52121 :b • E-325 MMF300(A) Series, FlreLlTeALarms MDF.300(A) Addressable Monitor Modules by Honeywell AddressableriDevices General Four different monitor modules are available for Fire'Lite's Intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4" (10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a more 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog Intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF-300 Monitor Module Built-in type identification automatically Identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use In intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class MMF-300 (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (lDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Maximum operating current: 375 iJA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125° (5.398 cm) deep box. MMF.301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. dt-52121:b.11/13108—Page lof4 5' I 1415 0 i IADDRESS 0 1 12 11 LOOP 9 87 61 ________ 9a 78 I TENS ONES F-. o w Ic - •- -.1 0 The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is Intended for use in Intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent,, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. it transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style 0 (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Une Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SIC loop. it responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 hA (LED flashing). EOL resistance: 3.91K ohms. External supply voltage (between Terminals 13 and 14): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 930/6 noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 cm) deep box. MDF-300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in Intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (10Cc) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) IOC circuits ONLY. Class A (Style D) IDC circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Maximum operating current: 750 hA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 320 to 120°F (00 to 490C). Humidity range: 10% to 93% (non-condensing). Maximum operating current: 375 hA. 400, Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Page 2 of 4—df-52121:b • 11/13/08 Dimensions: 450 (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "26", then It will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is Intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be In process. Consult fac- tory for latest listing status. UL: 82424 ULC: S3705 (Wsuffix models) FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information NOTE: "A"suffix indicates ULC Listed model. MMF400(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects'/Engineers' Specifications Specifications of these devices and all FireUte products are available from FireLite. df.52121:b • 11/13/08 -Page 3 of 4 Fire-Lite® and UteSpeed) are registered trademarks of Honeywell International Inc. 02008 by Honeywell international Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not Intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. BfftIIN IMMIMC1IIW All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.fireifte.com Page 4 of 4— df-52121:b • 11/13/08 CRF.300(A) RIv MntIuI. The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressabliity allows the dry contact to be activated through panel programming, on a select basis. UteSpeedIbl is a communication protocol developed by FireLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-In type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise Immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not satiable) will identify the module to the con- trot panel, so as to differentiate between a control module and a relay module. df-60379:AI • E-400 (a Fire Lrre'ALarms by Honeywell Addressable Devices ti3Tt flNC act.),, Z-111901111 I .a CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 VA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5 (11.43 cm) high x 4 (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (LIR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) 1 Non-Coded 125 VAC 0.5 A d1-60319:A1 • 084/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMBSOO: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LiteSpesdIM Is a trademark and FlreUte® Alarms Is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document is not Intended to be used for Installation purposes. Im ISO9001 We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. SIUMMINE &MNIFM1VUNI All specifications are subject to change without notice. QUALITY SYSTEMS Made ln the u.S.A. For more Information, contact Flre'Llte Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 20f 2—dt-60379A1.08/049 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division r SYSTEM SENSOR Duct Smoke Detector Accessories it Expand the versatility of the InnovairFIef line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories Duct smoke detector accessories add functionality to the duct APA1 51 Piezo Annunciator smoke detection system by allowing quick, convenient inspections MHR Mini-Horn, Red at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn, White The APA151 piezo annunciator, which replaces the APA45 1 with RA100Z/RA100ZA Remote Annunciator a new, improved look, provides an audible alarm signal, a red LED RTS1 51 Remote Test Station to indicate alarm status, and a green LED to indicate power status. RTS15 1 KEY Remote Test Station with Key It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to RTS2 Multi-Signaling Accessory comply with NFPA 90A. AOS Add-On Strobe The MHR and MHW SpectrAlert Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS1 51 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. Agency Listings FM LISTED APPRWW The RT52 and RTS2-AOS multi-signaling accessories are designed to work with lnnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. Specifications, Duct Smoke Detector Accessories Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non-condensing Wire Gauge 12to18AWG Dimensions 4.6"H x 2.9°W x .45D Advance Mini-Horns MHR/MHW SpectrAlert Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync.Circuit'° Module) Sounder Current Draw 22 mA RMS max. at 8 to 175 Volts DC 17 mA RMS max. at 8 to 17.5 Volts FWR 29 mA RMS max. at 16t0 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 0°C to 49°C (32°F to 12(°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3kHz Wire Gauge 12to18AWG Dimensions 4.6'H x 2.9W x 0.45°D Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 12 mA Dimensions 4.6° H x 2.8°W x 1.3'D RTS151 Rernote Test Station Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 1OVA@32VDC Reset Switch 10VA @32 VDC Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Dimensions 4.8'H x2.90°Wx 1.4°D Power Requirements Power LEO (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current 105 mA max. Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14t0 18AWG Dimensions 4.6'H x 2,75°W x 1.8'D Voltage 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8°W x 5.3'H x 1.60 For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. low RTS151 ULS4O11 RTS151KEYULS2522 APA151 UL S4011 RTS2-A05ULS2522 Wi RA100ZULS2522 MKWULS4O11 MHRULS4O11 Ac SYSTEM 3825 Ohio Avenue. St. Charles, IL 60174 MW 020105m5ensp. -_$ 5JtJ5Q Phone: 800-SENSOR2 . Fax: 630-377-6495 AOG-0423-001 2110. #2309 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Is LISTING No. 7300-1653:0212 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneyweIl.com DESIGN: Models RTSI 51, RTSI 51 KEY and RAIOOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed p\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not . be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAViD CAS71LLO, Program Coordinator Fire Engineering Division R E OF SYSTEM IN, SENSOR Indoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only Aciencv Listincis SONAUIIG IF M USTED APPROVED $5512 FM approved except 7125-165304 $4011 for AI.EHI models 7135-16530553 3057383.3057072 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 19i-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/s-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1'2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (Including lens) 5.6L x 4.7W x 1.91'D (143 mm Lx 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (Including lens) 5.26° Lx 3.46" W x 1.91° D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6L x 4.7W x 1.25D (143 mm x 119 mm x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45° W x 1.25" 0(133mm Lx 88mm W x 32mm 0) Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 uiu Horn rICurrenta Draw izrny:ii 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 DC Input III.Max, CurrentiDraw lrny:i Range 8-17.5 Volts 15cd 300d 16-33 Volts 15cd eI 300d 75cd 95cd llOcd 1350d 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.lKTemporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes L-Series Dimensions 1.91 I.u.— 3.46 1.25 I -I 2J 5. 1 7 II Compact Strobe I Horn Strobe 4.70 1.91 1.25 LM" I !~ Strobe I Horn Strobe L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT 3.46 _ 1.25 .27 Compact Horn Horn Horns HAIL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All-P models have a plain housing (no "FIRE marking on cover) All -SP models have FUEGO' marking on cover All -ALERT models have ALERT" marking on cover 5y57E,L,4 3825 Ohio Avenue • St. Charles, IL 60174 4=17 System Sensor. $ SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 Product speciftdons subject to charw wtmt notice. Mail systernumsoccom for current Product information. includhg the latestnerofon of this data eheet www.systemsensor.com AV0S86503 • 03117 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Im LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *p4vI,/I Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: *TR2 and 'TR-2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 3J an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 doe This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed gi the test results and/or other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division