Loading...
HomeMy WebLinkAbout7027 CORINTIA ST; ; AS080183; Permit3/7/24, 1:35 PM AS080183 Permit Data City of Carlsbad Sprinkler Permit Job Address: 7027 CORINTIA ST Permit Type: SPRINK Parcel No: 2237921300 Lot #: 0 Reference No.: Permit No: AS080183 Status: ISSUED Applied 12/16/2008 Approved: 12/16/2008 Issued: 12/16/2008 PC #: Inspector: Project Title: SHOTIS RESIDENCE THREE FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: SYMONS FIRE PROTECTION SUITE R 1050 PIONEER WAY EL CAJON, CA 619-588-6364 Owner: SHOTTS NORMAN&FLORENCE FAMILY TRUST 12-27-91 6534 CHURCH ST HIGHLAND CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 195 0 195 0 about:blank 1/1 Asoisoa HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. LICENSE : 682025 DESIGNER : CANDI CAUDILLO DATE : 11-10-2008 FILE : 08-234 JOB NAME : SHOTTS RESIDENCE 16'FT SLOPED LOCATION : 7027 CORINTIA STREET, CARLSBAD, CA DESIGN DATA. DESIGN CRITERION: NFPA 13-D MIN SPR FLOW : 13 Gpm AREA PER SPRINKLER : 256 Sq Ft TOTAL CALCULATED AREA : 512 Sq Ft TOTAL SPRINKLERS CALCULATED : 2 Heads FLOW DATA. TOTAL SPRINKLER FLOW : 26.4 Gpm DOMESTIC DEMAND : 5.0 Gpm TOTAL WATER REQUIRED : 31.4 Gpm been I evtc'% LII Ioi ippalefli ettipitatice ii iii liii UI teill ipplti..ihlt Li (ILL ,iiiil standard iii totCi i he ii sitiliOti 11w iLl lilt fl Lontracilir tita null/c iltis •. is ii suIpI I of all .i1ipltautilli for it building Al Inc e %pret.L underLiautdiuig that this revuill I-elle%es the owner or contractor or then tesiiional clip neeu or architect for sole re%ponsihililY liii lull cotnpltaitLi with said codes and standards. including the building code or for any responsihdty for dLltctcflciC5. errors. omissions or negligence in these plans whether or not noted in this review. I ).ute: O8 Reviewer: RECOMMEND APPROVAl. 0 RECOMMEND APPROVAL. AS NOTED LEA APPROVEJ!?4SUBMiT D CARLSBA Fl DEPART E T - BASE OF RISER NODE: 15 FLOW: 31.4 Gpm PRESSURE: 34.7 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DEPARTMENT PHONE : 760-602-4666 I-iYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 1 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 11-10-2008 File: C:\RESDEN43\08-234.RES JOB : SHOTTS RESIDENCE 16'FT SLOPED SOURCE I STATIC : 91.0 Psi RESIDUAL : 90.0 Psi FLOW : 31 Gpm DESIGN I SPRINKLER MANUF : RELIABLE MODEL : RFC 43 CONC/FLAT SPRINKLER Q : .0 Gpm VALVE : .0 Psi I SPRINKLER P : .0 Psi METER : 4.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet ----------------------------------------------------------- FACTOR Psi Gpm 1 14.0 4.3 9.2 13.0 2 14.0 4.3 9.6 13.4 3 14.0 9.6 4 11.0 15.0 5 11.0 17.0 6 11.0 14.6 7 .11.0 17.3 8 11.0 20.5 9 11.0 18.7 10 19.0 19.8 11 19.0 18.2. 12 19.0 20.6 13 19.0 21.9 14 19.0 24.3 15 4.0 34.7 5.0 DOME. 16 .0 39.8 17 5.0 39.8 18 2.0 . SOURCE 51.3 31.4 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 512 Sq Ft REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .051 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 26.4 Gpm TOTAL DOMESTIC FLOW : 5 Gpm TOTAL WATER REQUIRED : 31.4 Gpm TOTAL SPRINKLER PRESS : 47.3 Psi WATER METER LOSS : 4.0 Psi VALVE FIXED LOSS : .0 Psi Copyright (2002) SUPPLY PRESS AVAILABLE : 90.0 Psi by DEMAND PRESS REQUIRED : 51.3 Psi Hydronics Engineering- PRESSURE CUSHION : 38.7 Psi 34119 Fremont Bl, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 12.9 F/S (510) 487-9160 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 11-10-2008 File: C:\RESDEN43\08-234.RES JOB : SHOTTS RESIDENCE 161 FT SLOPED PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) - 1 q= 13.0 K= ------------------------------------------------------------------------------- 4.3 L= 3.0 Pt 9.2 Pt 9.2 1 Q= 13.0 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 15.0 .0308 Pf .5 Pn 9.0 3 Pt 9.6 2 q= 13.4 K= 4.3 L= 11.0 Pt 9.6 Pt 9.6 2 Q= 1.0 F= 2B F= 10.0 C= 150 Pe .0 Pv .0 Vel= .3 D= 1.101 TL= 21.0 .0003 Pf .0 Pn 9.6 3 Pt 9.6 2 q= 13.4 K= 4.3 -------------------------------------------------------------------------- L= 56.0 Pt 9.6 Pt 9.6 3 Q= 14.4 F= 3R4B3L F= 44.0 C= 150 Pe 1.3 Pv -.2 Vel= 4.8 D= 1.101 TL= 100.0 .0368 Pf 3.7 Pn 9.5 6 Pt 14.6 6 q= .0 K= .0 -------------------------------------------------------------------------- L= 44.0 Pt 14.6 Pt 14.6 4 Q= 14.4 F= 5R3B1E1L 28.0 C= 150 Pe .0 Pv -.2 .Vel= 4.8 D= 1.101 TL= 72.0 .0368 Pf 2.7 Pn 14.5 7 Pt 17.3 7 q= .0 K= .0 -------------------------------------------------------------------------- L= 60.0 Pt 17.3 Pt 17.3 5 Q= 14.4 F= 8R2B1L F= 25.0 C= 150 Pe .0 Pv -.2 Vel= 4.8 D= 1.101 TL= 85.0 .0368 Pf 3.1 Pn 17.1 8 Pt 20.5 8 q= .0 K= .0 -------------------------------------------------------------------------- L= 61.0 Pt 20.5 Pt 20..5 6 Q= 14.4 F= 3R1E2B F= 14.0 C= 150 Pe -3.5 Pv -.2 Vel= 4.8 D= 1.101 TL= 75.0 .0368 Pf 2.8 Pn 20.3 10 Pt 19.8 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 66.0 Pt 9.6 Pt 9.6 7 Q= 12.0 F= 7R2B10LF= 87.0 C= 150 Pe 1.3 Pv -.1 Vel= 4.0 D= 1.101 TL= 153.0 .0265 Pf 4.1 Pn 9.5 4 Pt 15.0 4 q= .0 K= .0 -------------------------------------------------------------------------- L= 52.0 Pt 15.0 Pt 15.0 8 Q= 12.0 F= 3R4B1E F= 24.0 C= 150 Pe .0 Pv -.1 Vel= 4.0 D= 1.101 TL= 76.0 .0265 Pf 2.0 Pn 14.9 5 -------------------------------------------------------------------------- Pt 17.0 5 q= .0 K= .0 L= 48.0 Pt 17.0 Pt 17.0 9 Q= 12.0 F= 5R2B1E F= 16.0 C= 150 Pe .0 Pv -.1 Vel= 4.0 D= 1.101 TL= 64.0 .0265 Pf 1.7 Pn 16.9 9 Pt 18.7 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 11-10-2008 File: C:\RESDEN43\08-234.RES JOB : SHOTTS RESIDENCE 161 FT SLOPED PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 9 q= .0 K= ------------------------------------------------------------------------------- .0 L= 74.0 Pt 18.7 Pt 18.7 10 Q= 12.0 F= 4R1B4L F= 37.0 C= 150 Pe -3.5 Pv -.1 Vel= 4.0 D= 1.101 TL= 111.0 .0265 Pf 2.9 Pn 18.6 11 Pt 18.2 11 - - q= .0 K= .0 L= 44.0 Pt 18.2 Pt 18.2 11 Q= 12.0 F= 2R3B4L F= 45.0 C= 150 Pe .0 Pv -.1 Vel= 4.0 D= 1.101 TL= 8.9.0 .0265 Pf 2.4 Pn 18.1 12 Pt 20.6 12 q= .0 K= -------------------------------------------------------------------------- .0 L= 24.0 Pt 20.6 Pt 20.6 12 Q= 12.0 F= 1R2B2L F= 25.0 C=.150 Pe .0 Pv -.1 Vel= 4.0 D= 1.101 TL= 49.0 .0265 Pf 1.3 Pn 20.5 13 . Pt 21.9 10 q= .0 K= -------------------------------------------------------------------------- .0 L= 25.0 Pt 19.8 Pt 19.8 13 Q= 14.4 F= 2R2B3L F= 33.0 C= 150 Pe .0 Pv -.2 Vel= 4.8 D= 1.101 TL= 58.0 .0368 Pf 2.1 Pn 19.6 13 Pt 21.9 13 q= .0 K= -------------------------------------------------------------------------- .0 L= 8.0 Pt 21.9 Pt 21.9 14 Q= 26.4 F= 1R1B1L F= 13.0 C= 150 Pe .0 Pv 5 Vel= 8.9 D= 1.101 TL= 21.0 .1135 Pf 2.4 Pn 21.4 14 Pt 24.3 14 q= .0 K= -------------------------------------------------------------------------- .0 L= 15.0 Pt 24.3 Pt 24.3 15 Q= 26.4 F= 1C4R1S1L F= 19.0 C= 150 Pe 6.5 Pv -.5 Vel= 8.9 D= 1.101 TL= 34.0 .1135 Pf 3.9 Pn 23.8 15 Pt 34.7 15 q= 5.0 DOME L= 5.0 Pt 34.7 Pt 34.7 16 Q= 31.4 F= 1G1B2L F= 10.0 C= 150 Pe 1.7 Pv -1.0 Vel= 12.2 D= 1.025 TL= 15.0 .2217 Pf 3.3 Pn 33.7 16 Pt 39.8 16 q= .0 K= -------------------------------------------------------------------------- .0 L= 250.0 Pt 39.8 Pt 39.8 17 Q= 31.4 F= 13C F= 13.0 C= 150 Pe -2.2 Pv -.1 Vel= 3.2 D= 2.003 TL= 263.0 .0085 Pf 2.2 Pn 39.7 17 Pt 39.8 17 q= .0 K= -------------------------------------------------------------------------- .0 L= 20.0 Pt 39.8 Pt 39.8 18 0= 31.4 F= 2C F= 4.0 C= 150 Pe 1.3 Pv -1.1 Vel= 12.9 D= .995 TL= 24.0 .2562 Pf 6.1 Pn 38.7 18 -------------------------------------------------------------------------- Pt 47.3 Meter = 4.0 19 Q= 31.4 <<< SOURCE >>> Pt 51.3 E=>45-E1b L=>90-E1b B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. DATE : 11-10-2008 FILE : C:\RESDEN43\08-234.REs JOB : SHOTTS RESIDENCE 16'FT SLOPED FIRE SPRINKLER HYDRAULIC GRAPH 10 15 20 25 30 ° Supply Curve Static : 91.0 Resid : 90.0 Flow : 31.0 35 40 45 50 FLOW - Gpm Demand Curve Avl Pr : 90.0 @ 31 Req Pr : 51.3 @ 31 Pr Cush: 38.7 Copyright: Hydronics Engineering, 2002. 34119 Fremont Bl, Suite 609, Fremont, CA. 94555. (510) 487-9160. PSI bc' 9C 8C 7C 60 50 40 30 20 10 0 Fl Res 40 Fl Res 40 HSW Recessed HSW/F2 Fl Res 49 CCP RFC 43 Pendent Bulletin 035 Rev.E liable Residential Sprinklers For Sloped Ceilings Guidelines for Listed Residential Sprinkler installations below Sloped Ceilings The installation guidelines cover Residential Sprinkler Models:. Fl Res 49 Pendent Fl Res 49 Recessed Pendent/F2 Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Fl Res 40 HSW Fl Res 40 Recessed HSW/F2 Fl Res 49 CCP RFC 43 Flat Concealed Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Fl Res 49 Pendent Fl Res 49 Recessed Pendent I F2 Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Patents: US Patent number 6,516,893 Model Fl Res 49 Product Description for Fl Res Sprinklers Model Fl Res Pendent sprinklers are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers, with a K Factor of 4.9 for pendent and 4.4 for horizontal sidewall, permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard *)• Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow Onto the deflector, evenly distributing the discharged water to control a fire. RFC 43 * Effective date July 12, 2002 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Product Description for RFC 43 Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 Sprinkler provides the best form of fire protection by combining an attractive appearance and ½' (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 is a UL Listed Residential Sprinkler to be installed in the residential portions of any occupancy in accordance with NFPA 13,13R, & 13D. The RFC43 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Technical Data (Fl Res Sprinklers): Thermal Sensor: Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinkler Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size : 1/2" NPT (R1/2) K Factor : 4.9 (Actual) - Fl Res 49 Pendent Sprinkler 4.4 (Actual) - Fl Res 44 HSW Sprinkler 4.0 (Actual) - Fl Res 40 HSW Sprinkler • Density : Minimum .05 gpm/ft2 Technical Data (RFC 43): Thermal Sensor: 165°F Fusible Link • Sprinkler Frame: Brass Machined Sprinkler Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size ': ½' NPT (R1/2) K Factor : 4.3 (Actual) Density : Minimum .05 gpm/ft2 Application Model Fl Res and RFC 43 Sprinklers are used for Residential Fire Protection according to UL 1626 Standard*. Be sure that orifice size, temperature rating, deflector style, cover plate and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving Authority Having Jurisdiction. * Effective date July 12, 2002 4. - - Model Fl Res 49 Pendent & Fl Res 49 Recessed Pendent/F1 & Fl Res 49 CCP Pendent & RFC 43 Pendent Flat Concealed Sprinklers installed below Sloped Ceilings. Fl Res 49 Pendent Fl Res 49 Recessed Pendent / F2 Fl Res 49 CCP Pendent RFC 43 Note: Fl Res 49 CCP Pendent and RFC 43 sprinklers are not suitable for installation in ceilings which have positive pressure in the space above. 4. Model F1 Res 49 Pendent & Fl Res 49 Recessed Pendent/172 installed below Sloped Ceiling. Technical Data F Thread Size Max. Pressure J psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length I Escutcheon I Sprinkler I Identification °F (°C ) (metric) I Number (SIN) I WNPT(R½ ) 175(12) 100(38) 4.9(69,94) 2.25' F2 J (Y'Adjustment) R3516 Table 1 - Application Max. Sprinkler Spacing Along Slope (W) Width x ( L) Length ft (m) Max. Slope of .l°) Pitch - Max. Slope of X2 (18.40) Pitch Mm. Flow Per Sprinkler __gpjLpm) Head Pressure psi (bar) Sprinkler Temp. Rating OF (°C) 155 (68) & 175 155°F (68°C) 175°F (79°C°) 155°F (68°C) I 175°F (79°C°) Mm. Flow Per Sprinkler Head gpm (Lpm) Pressure psi (bar)_ 12 x 12(3,6 x 3,6) 13 (49) 13(49) 7.0 (0,4 )] 7.0 (0,48L_13(49) 14 x 14(4,3 x 4,3) 13(49) 13 49 7.0(0,48) J 7.0 (0,48) - 13(49) - 7.0(0,48) - 16 x16(4,9 x 4,9) 13(49) 13 49 7.0(0,48) 7.0(0,48) 13(49) 7.0(0,48) 18 x18(5,5x 5,5) 17(64,3) 18 68,2 12.0O). 13.5(0,93)- 17(64,3). 12.0 (0,83) 20 x 20 (6,1 x 6, 1) 20(75,7) 21_ 16.7(1,15) j18.4(1,28) 20(75,7) 16.7 (1.15) Model Fl Res 49 CCP Pendent installed below Sloped Ceiling. Technical Data Sprinkler Temp. I CCP Assy. Temp. Max. Max. Ambient J Actual I K I I Sprinkler I Sprinkler I Thread Size Rating I Rating Pressure I Temp. I Factor I Length Identification I I °F(°C)I°F(°C) psi (bar) J_°F(°C) Number (SIN) I Y,' NPT(R) _155 (68) _135 (57) 175 (12)I_100 (38)I_4.9(6994)I_2.25' _(metric) _R3516 I Table 2- Application Max. Sprinkler Spacing Along Slope (W) Width x (L) Length ft (m) Max.Slope of 5(2(33.71 Mm. Flow Per Sprinkler Head gpm(Lpm) Pitch Pressure psi (bar) Max.Slope of (2 (18.401 Mm. Flow Per Sprinkler Head gpm (Lpm) Pitch Pressure psi (bar) 12 x12(3,6x 3,6) 14(53) 8.2(0,57) 13(49) 7.0(0,48) 14 x14(4,3 x 4,3) 14(53) 8.2(0,57) 13(49) 7.0(0,48) 16 x16(4,9 x4,9) 14(53) 8.2(0,57) 14(53) 8.2(0,56) 18x18(5,5x5,5) 21(79,4) 18.4(1,27) 20 x 20 (6,1 x 6, 1) 21(79,4) 18.4(1,27) Model RFC 43 Pendent Flat Concealed installed below Sloped Ceiling. Technical Data Thread Size I I Sprinkler I Temp. Rating °F (°C) I Coverplate . I Temp. Rating °F (°C) I. Max. I Pressure psi (bar) I Max. I Ambient Temp. °F (°C) Actual K Factor I (metric) Max. Adjustment Sprinkler I Identification I Number (SIN) 1/2 NPT(111/2) I 165(74) I 135(57) 175(1 2) 100(38) 4.3(61,4) I I RA0612 Table 3- Application Max. Sprinkler Spacing Along Slope (W) Width x ( L) Length ft (m) Max. Slope of 5(2(33.7° Mm. Flow Per Sprinkler Head gpm (Lpm) Pitch Pressure psi (bar) Max. Slop!t8.4° j( Mm. Flow Per Sprinkler Head gpm (Lpm) Pitch Pressure psi (bar) 12 x 12 (3,6 x 3,6) 18(68) 17.5(l.21) 13(49) 14 x 14 (4,3 x 4,3) 18(68) 17.5 K21) 13(49) 9.1(0,63) 16 x 16 (4,9 x 4,9) 18(68) 17.5(1,21) 13(49) 9.1 (0,63) 18 x 18 (5,5 x 5,5) 21(79) 23.8 (1,64) 20x20(6,1 x6,1) 21(79) 7. tqC0 Fire & Building IlPro duc ts Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TV-FRB - 2.8,4.2,5,6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT)or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy towhich the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices.• The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TV2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.01K, 3/4"NPT TY4231 - Pendent 8.01K, 3/4"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.01K, 1/2"NPT Page 1 of 10 MARCH, 2007 TFPI7I Page 2offlo TFPI7I 1/2" NPT ESCUTCHEON PLATE SEATING SURFACE 2-1/4" 6mm) (57,2 mm) 1- (39, 7/16(11,1 mm) STYLE 100r20 NOMINAL RECESSED ssu MAKE-IN ESCUTCHEON DEFLECTOR L 7/16" 1 (11,1mm) I NOMINAL I MAKE-IN 2-3/16" WRENCH (55,6 mm) FLATS 1/2" NPT SSP DEFLECTOR * H— 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3-Sealing 4- Bulb 6- Deflector 2 - Button Assembly 5 - Compression 7 - Bushing Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE 1/2" MAKE-IN ESCUTCHEON SSU 2-3/16" (55.6 mm) -- / NOMINAL 1,1 mm) NPT DEFLECTOR 7/16" 6* (1 116,, (556mm) I (38.1 mm) \ \Jj . 11/'NWRENCH MAKE-IN 1-1/2" 2 3/ FLATS 1 SSP DEFLECTOR * 2-7/8" (73.0 mm) DIA. -'-I 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT 6* 1/2" 5 (12,7 mm) NOMINAL 4 MAKE-IN 2 2-1/4" (57,2mm) CROSS SECTION TFPI7I Pace 3 of 10 ESCUTCHEON PLATE SEATING SURFACE \-i 2-3/16' (55,6 mm) 1-1/2" (38,1 mm) 1/2" NPT 7/16"(11,1 mm) STYLE 10 or 20 NOMINAL RECESSED MAKE-IN ESCUTCHEON SSU DEFLECTOR (N( mm) 1 " 'II II NAL -IN2-3/16" WRENCH (55,6 mm) FLATS 1/2"NPT SSP DEFLECTOR * H— 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is Indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE '" MAKE-IN NPT 2-5/16" (58,7 mm) T1 I 1-9/16" I (39,7 mm) L WRENCH FLATS " SSP DEFLECTOR * 2-7/8 (73,0 mm) DIA. 3/4 NPT PENDENT RECESSED PENDENT UPRIGHT STYLE 30 or 40 RECESSED ESCUTCHEON SSU* DEFLECTOR - Frame 3-Sealing 4-Bulb 6 -Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT 2-1/4" (57.2 mm) _______ 1-9/16" (39,7 mm) S Page 4 of 10 TFPI7I 7/16" (11,1 mm) NOMINAL SSU MAKE-IN DEFLECTOR 1/2" NPT '.- ssP* DEFLECTOR PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl'2) K = 4.2 GPM/p5i1/2 (60,5 LPM/bar"2) K = 5.6 GPM/psi1l2 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13,and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ).'Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. 1- Page $ of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME I WHITE*** LEAD LIQUID BRASS PLATED JPOLYESTER COATED' 135°F/57°C Orange PENDENT (TY3231) and 1,2,3,4,5,6,7 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 5.6 1/2" UPRIGHT (TY3131) 200°F/93°C Green 286°F/141°C Blue NPT 135°F/57°C Orange 1,2.4.5 N/A RECESSED PENDENT (TY3231)* 155°F/68°C Red 175°F/79°C Yellow Figure 10 200°F/93°C Green 135°F/57°C Orange I I 1,2, 1.2,4.5 N/A RECESSED PENDENT cry3231r 155°F/68°C Red 175F/79°C Yellow Figure 11 Green 200°F/93°C 135°F157°C Orange 8.0 PENDENT (TY4231) and UPRIGHT (TY4131) 3/4,, 1, 2, 3, 4, 5, 6, 7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT 135°F/57°C Green 1,2,4,5 N/A RECESSED PENDENT (TY4231)* 155°F/68°C Orange 175°F/79°C Red Figure 12 200°F/93°C Yellow 135°F/57°C Orange 1,2,3.4.5 ' N/A RECESSED PENDENT (TY4231) 155°F/68°C Red 175°F/79°C Yellow Figure 13 200°F/93°C Green 135°F/57°C Orange 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) ' 1, 2,4, 5, 6 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 1 286'F/141*Cl Blue NOTES: Listed by Underwriters Laboratories, Inc.(UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick-Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2° NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TABLE C, MAXIMUM WORKING PRESSURE TFP17 K PENDE 2.8 UPRIG RECESS NPT C PENDE 4.2 UPRIG RECESS NPT (T PENDE 5.6 UPRIGI 1/2" RECESS NPT (1 PENDE 8.0 UPRIGI RECESS NPT T 8.0 PENDEI 1/2" NPT UPRIG NOTES: 1. The maximum working Underwriters Laboratories Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135F/57°C to 3/32 inch (2,4 mm) for the 2860F/I410C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum. of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20.ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler., Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin-. kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 5 of 10 2-7/8" DIA. i 5/8±1/4' (73.0 mm) I 3/4"(19,1 mm) - (15,9*6,4 mm) - 2-1/4" DIA. 1/4(6,4mm) I SPRINKLER I I PLATE I FACE OF _57,2 mm) MOUNTING FITTING 1/8" (3,2 mm) MOUNTING SURFACE ,, / 1-5/16 (33,3 mmi CLOSURE SERIES TY-FRB 13116"(20,6 mm) FIGURE 6 SERIES TY..FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (159±6,4 mm) 2-1/4' DIA. I 1/4'(6,4 mm) I I FACE OF (57.2 MOUNTING SPRINKLER PLATE I FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) I TY..FRB 3/4"(19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I 2-7/8"DIA. 1/2±1/8" (73,0 mm) 1/2' (12.7 mm) E (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I FACE OF ' p-.' MOUNTING I SPRINKLER FITTING 2mm) PLATE 1/8" / (32mm) I MOUNTING I \ SURFACE fCLOSURE SERIES (33,3 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. (73,0 mm) 1/2±1/8" I 1/2"(12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4"(6,4 mm) I I SPRINKLER PLATE I FACE OF (57,2 mm) MOUNTING ; I FITTING 1/8" / (3,2 mm) I \ MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TYFRB 1"(25,4 mm) FIGURE 9 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- 4 TFPI7I Page 9 of 10 2-7/8 DIA. 5/8 (73,0 mm) 3/4' (19,1 mm) ±1/4" (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I I FACE OF MOUNTING (57,2 SPRINKLER PLATE FITTING 4t_____ MOUNTING,,,/./ I SURFACE CLOSURE SERIES 1-1/4"(31.8 mm) TY-FRB 314"(19,11 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 5/8±1/4" (73,0 mm) .3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I FACE OF (57,2 MOUNTING I SPRINKLER PLATE FITTING ________ 1/8" I _ 2mm) MOUNTING SURFACE I CLOSURE SERIES 1-5/16" (33,3 mm)I TV. FRB 13/16"(20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT 2-7/8" DIA. - 1/2±1/8" I (73,0 mm) 1/2(12,7mm) E (127±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) I SPRINKLER PLATE I FACE OF 57.2 mm) 'j MOUNTING I ;)/# 1/8" FITTING (32mm) 4 _J t \ MOUNTING I I SURFACE SERIES 1-1/4"(31,8 mm) CLOSURE TV..FRB 1"(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. •i 1/2±1/8" (73,0 mm) 112"(12,7 mm) [(12,7±3,2 mm) 2-1/4' DIA. 1/4"(6,4 mm) I FACE OF (57,2 mm) MOUNTING I I SPRINKLER PLATE I I FITTING (3.2 1/8" mm) I ___ / 4t_ I \ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 1-1/16"(27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT plated, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes.