HomeMy WebLinkAbout2035 CORDOBA PL; ; AS080184; Permit3/7/24, 1:34 PM AS080 184 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2035 CORDOBA PL Permit Type: SPRINK Parcel No: 2072403700 Lot #: 0 Reference No.: Permit No: AS080184 Status: ISSUED Applied 12/17/2008 Approved: 12/17/2008 Issued: 12/17/2008 PC #: Inspector: Project Title: DUKE'S GUEST HOUSE RESDIENTIAL FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: VANGUARD FIRE PROTECTION 1604 LA MIRADA DR #105 SAN MARCOS CA 760-727-8540 Owner: DUKES GREGORY S&CAMILLA E 2035 CORDOBA PL CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 260 0 260 0 about:blank 1/1 Remote Area Number: 1 Telephone: 760-727-8540 IAR Za S. / L E DEPAr Occupancy: R3 AsoTO184- 1.JKES GUEST ROUSE Drawing Date:3-19--08 3120108 9:23 HYDRAULIC DESIGN INFORMATION SHEET Job Name: DUKES GUEST HOUSE Location: 2035 CORDOBA PLACE CARLSBAD, CA Drawing Date: 3-19-08 Contractor: VANGUARD FIRE PROTECTION 925 POINSETTIA SUITE 11 VISTA, CA 92081 Designer: S.B. Calculated By: SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: V-NR Reviewing Authorities : CFD SYSTEM DESIGN Code:NFPA 13D Hazard:RESIDENTIAL System Type:WET Area of Sprinkler Oper. 512 sq ftl Sprinkler or Nozzle Density (gpm/sq ft) RES I Make: TYCO Area per Sprinkler 256.0 sq ftl Model: LFII Hose Allowance Inside 0 gpm I K-Factor: 4.90 Hose Allowance Outside 5 gpm I Temperature Rating: 155 CALCULATION SUMMARY 2 Flowing Outlets gpm Required: 31.0 psi Required: 47.9 @ Source WATER SUPPLY Water Flow Test I Pump Data I Date of Test 3-19-08 I Rated Capacity 0 gpm I Static Pressure 68.0 psi I Rated Pressure 0.0 psi I Residual Pres 67.9 psi I Elevation 0 I At a Flow of 50 gpm I Make: I Elevation 0" I Model: I Location: AT METER Source of Information: CFD SYSTEM VOLUME 9 Gallons Notes: dDVIES GUEST ROUSE Drawing Date:3-19-08 3/20/08 9:23 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 26 19.9 psi 1 1" CPVC 90 Eli 5' 120 1.049 26 1.3 1 Pipe 1" PVx15 9' 150 1.101 26 1.0 Elevation Change 91 0" 3.9 1 1" Thrd Check Valve Generic NFPA Va 5' 120 1.049 26 1.1 Hydr Ref BOR Required at BASE OF RISER 26 27.2 psi 2 1" Sweatd 90 Eli 120 1.049 26 1.3 1 Pipe 1" Kx21 Copper 4' 150 0.995 26 0.7 Fixed Flow Outside Hose Allow. 5 gpm 1 1-1/4" CPVC 90 Eli 120 1.380 31 0.7 1 Pipe 1k" PVx15 25' 150 1.602 31 0.6 1 1-1/4" CPVC 90 Eli 6' 120 1.380 31 0.7 1 Pipe 1k" PVx15 110' 150 1.400 31 5.2 2 1-1/4" CPVC 45 Eli 0' 120 1.380 31 0.0 1 Pipe 1k" PVx15 10' 150 1.400 31 0.5 Elevation Change 21 0" 0.9 1 1" Thrd Other Valve 1" MTR " ". CHART LOSS 31 4.0 1 Pipe 1" Kx21 Copper 15' 150 0.995 31 3.8 1 1" Sweatd Tee 6' 120 1.049 31 2.2 Hydr Ref SC , Required at Source 31 47.9 psi Water Source 68.0 psi static, 67.9 psi residual @ 50 gpm 31 gpm - 68.0 psi SAFETY PRESSURE 20.0 psi Available Pressure of 68.0 psi Exceeds Required Pressure of 47.9 psi This is a safety margin of 20.0 psi or 29 % of Supply Maximum Water Velocity is 8.8 fps DURES GUEST ROUSE Drawing Date:3-19-08 3/20/08 9:23 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'$ Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)"1.85 / ID"4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x QA2/IDA4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations bUKES GUEST ROUSE Drawing Date:3-19-08 3/20/08 9:23 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM NUMBER K-FACTOR FLOW FLOW (FT) (GPM/(PSI-:Ii)) (PSI) (GPM) (GPM) 1 19.50 7.0 18 19.00 4.90 7.1 13.0 13.0 2 19.50 7.0 2S 19.00 4.90 7.0 13.0 13.0 11 19.50 7.7 Al 8.50 19.7 31 8.50 17.4 W 8.50 19.9 Max velocity of 8.85 occurs in the pipe fromBi TO 11 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an 'TS" is on the branch. ACTUAL DENSITY (GPM/SQ. FT) 0.05 0.05 VKES GUEST ROUSE HYD. Qa DIA. REF "Cu POINT Qt Pf/ft Drawing Date:3-19-08 Tyco Fire Products FITTING PIPE Pt TYPES FTNG'S Pe TOTAL Pf 3/20/08 9:23 Page 5 Pt PV ******* NOTES '******* Pn PATH 1 FROM HYDRAULIC REFERENCE 2 TO W (PRIMARY PATH) 12.96 1.101 1E 0.50 7.0 7.0 K = 4.90 2S 0=150 5.00 -0.2 0.0 12.96 0.031 5.50 0.2 7.0 Vel = 4.41 1.101 1E 13.50 7.0 7.0 EqK = 4.92 2 0=150 iT 10.00 0.0 0.0 12.96 0.031 23.50 0.7 7.0 Vel = 4.41 13.04 1.101 2E 28.92 7.7 7.7 11 0=150 iT 16.00 4.8 0.0 See PATH 2 26.00 0.111 is 44.92 5.0 7.7 Vel = 8.85 1.101 1E 9.82 17.4 17.4 Bi 0=150 iT 11.00 0.0 0.0 26.00 0.111 is 20.82 2.3 17.4 Vel = 8.85 1.101 1.73 19.7 19.7 Al 0=150 0.00 0.0 0.0 26.00 0.111 1.73 0.2 19.7 Vel = 8.85 W 26.00 19.9 K = 5.83 PATH 2 FROM HYDRAULIC REFERENCE 1 TO 11 13.04 1.101 iE 0.50 7.1 7.1 K = 4.90 is 0=150 5.00 -0.2 0.0 13.04 0.031 5.50 0.2 7.1 Vel = 4.44 1.101 1E 10.67 7.0 7.0 EqK = 4.92 1 0=150 iT 10.00 0.0 0.0 13.04 0.031 20.67 0.6 7.0 Vel = 4.44 11 13.04 7.7 K = 4.71 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) tqco /Fire & Building I Products rapid response TM Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 HOME FIRE SPRINKLER SYSTEM Series LFII Residential Concealed Pendent Sprinkler, Domed Plate 49 K-factor General Description The Series LFII (TY2234) Residential Concealed Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The domed profile of the cover plate provides aesthetically appealing sprinkler design with lower flow rates than can be achieved by lower profile cover plates. The separa- ble two-piece design of the Cover Plate and Support Cup Assemblies al- lows installation of the sprinklers and pressure testing of the fire protection system prior to the installation of the ceiling or application of a finish coat- ing. Also, the separable "push-on and thread-off" two-piece design of the Sprinkler provides for 1/2 inch (12,7 mm ) of vertical adjustment. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 1313; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. 1311; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series IFlI (TY2234) has a 4.9 (70,6) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The Series LFII (TY2234) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII (TY2234) Residential Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed for installation, and it must be replaced to protect the sprinkler while the ceiling is being installed or fin- ished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceil- ing tiles, etc. by gently pushing the ceiling product against the Protective Cap. When ceiling Installation is com- plete, the Protective Cap must be re- moved and the Cover Plate Assembly installed. The Protective Cap must be removed to ensure proper perform- ance of the sprinklers. WARNINGS The Series LFlI (TY2234) Residential Concealed Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any otherauthorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. SprinklerNodel Identification Number SIN TY2234 Technical Data Approvals: UL and C-UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/psil12 (70,6 LPMIbarl12) Temperature Rating: 155°F/68°C Sprinkler with 135°F/57°C Cover Plate Vertical Adjustment: 1/2 inch (12,7 mm) Finishes: Cover Plate: Flat White, Bright White, Chrome, or Custom Page 2 of 6 TFP45O Minimum Flow (b) and Minimum Flow and Minimum Flow and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area Ft (Max. 2 Inch Rise (Greater Than 2 Inch Rise (Greater Than 4 Inch Rise Ft. x Ft. (m) for 12 inch Run) Up To Max. 4 Inch Risi Up To Max. 8 Inch Rise (mx m) for 12 inch Run) for 12 inch Run) 155°F1680C 1550F168°C 155°F1680C Sprinkler Sprinkler Sprinkler 12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 19 GPM (71,9 LPM) (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 15.0 psi (1,03 bar) 14 x 14 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 19 GPM (71,9 LPM) (4,3 x 4,3) (4,3) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 15.0 psi (1,03 bar) 1606t 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) - 19 GPM (71,9 LPM) (49x49) (4,9) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 15.0 psi (1,03 bar) 18 x 18 18 17 GPM (64,3 LPM) 1 17 GPM (64,3 LPM) 19 GPM (71,9 LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 15.0 psi (1,03 bar) 20 x 20 20 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) 24 GPM (90,8 LPM) (6,1 x6,1) (6,1) 16.7 psi (1,l5bar) 18.4 psi (1,27 bar) 1 24.o psi (1,65bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2234) RESIDENTUL CONCEALED PENDENT SPRINKLER Physical Characteristics: Frame ..............Brass Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/ Teflon* Bulb .........3 mm dia. Glass Compression Screw ......Brass Deflector ...........Copper Button Ejection Spring ........ ......Stainless Steel Support Cup ..........Steel Cover Plate ...........Brass Retainer ............Brass Cover Plate Ejection Spring ..... ......Stainless Steel *DuPont Registered Trademark Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. The glass bulb con- tains a fluid that expands when ex- posed to heat. When the rated temperature is reached, the fluid ex- pands sufficiently to shatter the glass bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFlI (TY2234) Residential Concealed Pendent Sprinklers are UL and C-UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the Authority Having Jurisdic- tion. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 2. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Ta- ble A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). TFP45O SEALING FRAME ASSEMBLY (112"NPT) WRENCH IIIiiiiii;1I BUTTON FLATS SUPPORT DISPOSABLE L I CUP WITH SPRINKLER I ROLL FORMED STRAP(SEE I I THREADS INSTALLATION I SECTION)I BULB DEFLECTOR ICOMPRESSION PRINKLER/SUPPORT CUP I I SCREW I ASSEMBLY THREAD INTO I RETAINER SUPPORT CUP WITH THREAD 'i— UNTIL MOUNTING 1 01 101 TABS SURFACE IS II 1 FLUSH WITH II EJECTION CEILING II 1 SPRING Page 3 of 6 WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 SPRINKLER WRENCH TABS (3) \ COVER PLATE COVER PLATE/RETAINER ASSEMBLY FIGURE 1 SERIES LFII (TY2234) RESIDENTIAL CONCEALED PENDENT SPRINKLER (Shown with Disposable Sprinkler Strap) 2-112"DIA. I 1/2" 63,5 mm NPT... MOUNTING SURFACE COVER- SPRINKLER- 15/16" j RETAINER SUPPORT CUP (23,8 mm) ASSEMBLY ASSEMBLY _____ 35116"DIA. _____ SPRINKLER- SUPPORT C" ASSEMBL COVER PLATE RETAINEI 1/4"(6,4 mm) 3/4" (19,1 mm) DISPOSABLE o'I,i rums TIP PROTECTIVE CAP FIGURE 3 SERIES LFII (TY2234) RESIDENTIAL CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS I DISPOSABLE PROTECTIVE CAP I 112"(12,7 mm) FACE OF I THREADED SPRINKLER I ADJUSTMENT FITTING E—/3/32"GAP 1-3/I (2,4 mm) - (30,2 mm ±6,4 mm) \ OPERATED SPRINKLER Page 4 of 6 TFP4SO Installation The Series LFII (TY2234) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6mm). A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. NOTE Do not remove the Sprinkler Strap (Fig. 1) until the sprinkler system is to be placed in service. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W-Type 7 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup- port Cup Assembly into the fitting. The W-Type 7 Wrench will accept a 112 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Arms during ceiling in- stallation and/or during application of the finish coating of the ceiling. it may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. NOTE As long as the Sprinkler Strap (Fig. 1) or the Protective Cap (Fig. 3) remains in place, the system is considered to be "Out Of Service" Step 5. After the ceiling has been com- -pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate/Re- tainer Assembly, remove and discard the Protective Cap and the Sprinkler Strap. NOTE Refer to Technical Data Sheet TFP700 regarding instructions for the removal of the Sprinkler Strap. Step 6. Push the Cover Plate/Retainer Assembly into the Support Cup, and as necessary, make the final adjustment of the Cover Plate with respect to the ceiling by turning the Cover Plate/Re- tainer Assembly clockwise until its flange just comes in contact with the ceiling. If it becomes necessary to remove the Cover Plate, it can be removed by un- screwing in a counter-clockwise direc-tion. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fit- ting must be repositioned. Care and Maintenance The Series LFII (1Y2234) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP45O Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims -based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theOry. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability. Sprinkler Assembly: Series LFll (TY2234), K=4.9, Residen- tial Concealed Pendent Sprinkler with- out Cover Plate Assembly, P/N 51-873-1-155. Cover Plate Assembly: Cover Plate Assembly having a (spec- ify) finish for the Series LFII (1Y2234), K=4.9, Residential Concealed Pen- dent Sprinkler, P/N (specify). Chrome .................P/N 56.873-9-135 Off White ................PIN 56-873-0-135 Bright White .............. P/N 56-873-4-135 Flat White................PIN 56.873-5-135 White (RAL 9010) .......... P/N 56-873-3-135 custom..................PIN 56-873-x-135 *Eastem Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 7 Sprinkler Wrench, PIN 56-850-4-001.