Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6211 CORTE DEL ABETO; ; FA060073; Permit
3/7/24, 3:55 PM FA060073 Permit Data City of Carlsbad Fire Alarm Permit 6211 CORTE DEL Job Address: ABETO Permit Type: FALARM Parcel No: 2130610200 Lot #: 0 Reference No.: Permit No: FA060073 Status: ISSUED Applied 10/27/2006 Approved: 11/6/2006 Issued: 11/6/2006 PC #: Inspector: Project Title: PUBLIC STORAGE T.I. FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: GREATER ALARM CO 17992 COWAN IRVINE CA 949-474-0555 Owner: PUBLIC STORAGE INC DEPT PT CA 07212 P 0 BOX 25025 GLENDALE CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 117 0 117 0 about:blank Ill THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT Underwriters Laboratories Inc ® Applicant ID No 743925-001 Northbrook, IL Santa Clara, CA .:. Service Center No 1 Melville, NY Research Triangle Park, NC Expires: 31-MAR-200.7 Camas, WA A not-forprctitorganization dedicated to public safety and committed to quality service CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to Use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL s Certificate Verification Service Listed Service From IRVINE, CA Alarm Service Company (743925-001) Service Center. (743925-001) GREATER ALARM CO INC GREATER ALARM CO INC 17992 COWAN AVE 17992 COWAN AVE IRVINE CA 92614 IRVINE CA 92614 The Alarm Service Company is Listed in the following Certificate Service Categories File - Vol No CCN Listing Category BP8539 .1 CPRH [Burglar Alarm Systems] Bank BP9641 - 1 CRZH [Burglar Alarm Systems] National Industrial Security Systems BP8540 - 1 CVSG [Burglar Alarm Systems] Mercantile . S7279 -1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective S3388 -1 UUJS . Signaling Services) Central Station [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Local, Auxiliary, Remote Station and - . Proprietary . . APR-03-2006 15:52 U'LcERTIFicflTE SERVICE 8475098245 P.02/02 ® Underwrlters.Labtñtuules Inc.-@' Northbrook. It. Sane CIm, CA M&uUIo, NY Resoarthldangt. Pwlc, NC Cnias.WA A floI4OPp,vlto nIzatIonddIffidIO public uI,ty and mquaIyUlv1C Applicant ID Nô:750680-001 Service Center NQ 1•• Expires: 31-MAR-2007 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm SaMoa Company Indicated below is included by Underwriters Laboratories Inc. (UL) In Its Product Directories as eligible to use the UL Listing Mark In connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements Is the Issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. Listed Service From EARTH CITY, MO Alarm Ssnice Comoany: I75068Q.oafl Service Center: (750680.001) INTERFACE SECURITY SYSTEMS L L C INTERFACE SEdURITY SYSTEMS L LC 3m CORPORATE CENTER DR. 3773 CORPORATE CENTER DR EARTH CITY MO 63045 EARTH CITY MO 63045 The Alarm Service Company is Listed in the following Certificate Service Categories File -oLNo CCN Listing Cateaory BPSS4S 1 CPVX [Brglar Alarm Systemsi Central Sttipn 05211-1. UUFX [Signl and Fire Alsnn Equipment and Services] (Protective . $5402-I UWS Signaling SirvJcé) Central StatIon. •: [sánal.ànd.Fire Alarm Equipment and Servlcs..(ProR .bt tctIvi Signaling sorvló.$) Local. Auliliary, é Station and Proprietary "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" o ieee vi. FWTTI 03-CC • 03-APR-2006 TOTAL P. 50 Point Analog/Addressable Fire Alarm Control System Up or Down load programming, event history, or detector status via remote or direct connection. Integrated dead front panel protects operator from exposure to electrical components. Programmable to automatically display initial event first or display tally of system events. Acknowledge function allows operator to keep track of event status. Approvals UL Listed NFPA -Central Station -DACT Local Protective Signalling System -Water Deluge Releasing Service CSFM Pending Specifications Dimensions: 12-3/4"W x 15-1/8'H x 3-3/8'D (32.39 x 38.42 x 8.57 cm) Weight: 11.5 lbs. (5.2 kg) Color: Red P/N 350328, 04103 Copyright 02003 Silent Knight Jumpstarts is a Register Trademark of Silent Knight Fa' ren hyt IFP-50 Intelligent Fire Panel The IFP-50 is an intelligent analog/addressable fire control panel. The IFP- 50 system has a single SLC loop, which can support 50 SLC devices. The IFP-50 has two Notification Appliance Circuits that can be programmed for notification outputs, or auxiliary power. The control panel also has a built-in dual line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation and pre-trouble maintenance alert. The IFP-50 supports a variety of other devices that can be added to the system such as the RA-1 00 Remote Annunciator, the Model 5824 Serial/Parallel Interface (for printing system reports), and the 5496 Intelligent Power Module. Features Built-in support for 50 analog addressable points. Uses standard wire—no shielded or twisted pair required. Built-in digital communicator for remote reporting of system activity and system programming. Central station reporting by Point or by Zone. Jumpstart® auto-programming. Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC. Distributed, intelligent power. Built-in synchronization for appliances from Gentex®, Faraday, System Sensor®, and Wheelock® Sensor sensitivity settings and Day/Night sensitivity setting. Automatic drift compensation. Notification circuits can be configured as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for ressetable, constant, or door holder power. Built-in annunciator with a backlit 80-character LCD display. RS-485 bus provides communication to system accessories. Built-in RS-232 interface for programming via PC. Built-in Form C trouble relay rated at 2.5 amps at 24 VDC. Two built-in Form C programmable relays rated at 2.5 amps at 24 VDC. Individual addressable devices can be tested. SLC device locator can be used to locate a single or multiple devices on a SLC loop. System automatically performs detector sensitivity test. 13 preset notification cadence patterns including ANSI 3.41 and four user programmable patterns. System can be uploaded or downloaded on site or from a remote location with a PC. Non volatile event history stores up to 1000 events. 125 Software zones and 125 output groups. Maximum charging capacity of 12 amp hours. (An additional cabinet enclosure is required for batteries in excess of 7 amp hours.) .• SLC Supports multiple Device types. (See compatible addressable devices.) Any combination of addressable devices can be used on a single SLC loop (up to a 50 devices). 7550 Meridian Circle I SILENT Maple Grove, Mn 55369-4927 I KNIGHT 763-493-6455 1 1-600-328-0103 I Fax: 763-493-7475 I A HonevaU Company I http:IIwww.farenhytcom I 1. IFP-50 $496 Electrical Specifications Battery Charging Capacity Up to 33 Ah Primary AC: 120 VRMS © Telephone Requirements: 50 / 60 hz 1.5.A FCC Part 15 and Part 68 approved Total Accessory Load 2.5 A @ 24 VDC Type of Jack RJ31X (two required) .2 .5 Amps @ 24 VDC of power-limited notification power Standby Current: 160 mA Alarm Current: 330 mA t Information . Accessory Product 5D505-ADHR!DTS—The S0505-ADHR analog addressable RA-100/RA-1000 Remote Annunciators-80 character backlit duct smoke detector with built-in relay module detects products of combustion present in air moving through an HVAC system. : LCD display with a built-in keypad The system can be fully The S0505-ADHR is compatible with the SD505-DTS which programmed and operated from any remote annunciator The provides remote annunciation and testing capabilities for the lFP-50 can support up to 8 RA 100 remote annunciators per system. . . . . . S0505-ADHR SD505-ADH—Analog addressable duct housing. Unit ships 5824 Serial Parallel Module—The 5824 is a serial/parallel with an attached detector base whichi is compatible with the interface that is used to connect .a serial or parallel computer SD505-AlS or SD505-APS smoke detectors. (Detector and printer to the IFP-50 control panel via the RS-485 system bus. . sampling tubes ordered separately.)- Up to two 5824 modules can be used with a system 5880 LED/Input-Output Module—The 5880 provides 40 . SD500 AIM—Addressable input module used to connect pull stations"water flow switches, and other applications requiring programmable LED outputs and eight supervised dry contact dry contact alarm initiation devices The AIM mounts into a 4 inputs Up to eight 5880 modules can be used on the IFP 50$ square electrical box SBUS 5865-3 and 5865-4 LED Fire Annunciators—The 5865 series . SD500 MIM—Mlni Addressable input module used to connect 'pull stations, water flow switches, and other applications annunciators provide a visual indication of the current state of requiring dry contact alarm initiation devices The MIM mounts the zone inputs on the control panel Up to 8 Model 5865s can be used on the IFP-50's SBUS. Each 5865 has 30 . into a single gang electrical box SD500-LIM—Addressablé Line isolator module.that isolates programmable LED outputs-15 red and 15 yellow. The 5865s short circuit wiring fault on a Style 7 (Class A) -SLC loop. come with a piezo sounder which gives an audible indication during alarms, troubles and supervisory troubles. S13600-ARM—Addressable Relay Module allows you to control 5883—The 5883 Relay Interface Board provides 10 general a normally open or closed device such as; elevator recall, door• purpose Form C relays that can be used to control any, device . closing, fan operations, and auxiliary notification. Relay can be that requires a dry contact closure. mapped to any zone condition. The ARM has two Form C contacts and mounts into a 4" square electrical -box. SD505-APS—Analog addressable photoelectric smoke detector. . . . 5496 Intelligent Power Module—The Model 5496 is a 6 amp. notification power expander that provides four additional 5D505-AHS--Analog addressable heat sensor. power-limited notification appliance circuit outputs. SD505-6AB—Six inch base designed for use with detector, 5650 Down load Software—User-friendly software for remote head models S0505-APS, 5D505-AIS, and SD505AHS. programming of the IFP-50. The software is compatible with S0505-6113---6 inch isolator base. The 8D505-61B isolates a Window 95, Windows 98, and Windows NT. short circuit wiring fault on a Style 7 (Class A) SLC loop. 5670 IntelliView Facility Management Softwaré—End-user SD500 PS/PSDA—The SD500 PS/PSDA are a single action or software allows viewing of detector status and event history via modem or direct connect. • • • dual action addressable fire pull stations featuring rugged metal construction with visible LED 7550 Meridian Circle Maple Grove MN 55369-4927 SILENT or in Minnesota 763-493-6435 . ___________ - 1-800-446-6444 • • D M-493-6475 •.' KNIGHT - FAX: • • - -- ___________- • iicrpy World Wide Web hftp://www.farenhyt.COM Made in the U S.A Rechargëáble• Valve Regulated Sealed LeadAcid Batteries Features a Rechargeable a Non-spillable a Non-hazardous U Lowniaintenance. Highenergydénsity Description $ pecifications Rechargeable sealed lead-acid batteries areideat far useas a secondary (standby) power source as defined byNFPA 72. Their low maintenance and high energy density makethemn ideal for fire alarm signaling applications. Application When multiple power supplies are provided,each power supply's bat.tery req uiremneats should be calculated individually Consultthe specific system manualto determine battery capacityrequire nients. Safety Information Due to a battery's low internal resistance and high power density, high levels of short circuit current can develop across battery terminals. Put on protective eye covering and remove all jewelry before working on batteries. Do not rest tools or cables on the battery, and only use insulated toots. Follow all manufacturers installation instructions and diagrams when installing or maintaining batteries. Case Material ABS Thermoplastic Regulatory DOT Osos 60, Bateries, non-hazardous, Information non-spillable Operating 32°.Fto120°F(0°Cto49C) Environment Oto 93% RI-i, Non-condensing Ordering Information Catalog Number D i - on . s i Weight Ill (kg) 12V1A2 1.2 Ah Seated Lead Acid Battery - 12 Vdc 1.25(0.57) 12V44 4.5 Ah Sealed LeadAcid Battery - 12 Vdc 5(2.27) 12V6A5 7.2 Ah Sealed LeadAcid Battery.- 12 Vdc 6(2.72) 6V8& . 8Ah SeAled Lead Acid Battery - 6Vdc 4(1.81) 6V10A 12 Ah Sealed Lead Acid Battery - 6Vdc' 5(2.27) 12V1OA 11 Ah Sealed Lead Acid Battery - 12 Vdc 10(4.45) 12V1 7A 18 Ah Seated Lead Acid Battery - 12 Vdc 13(5.90) 12V24A 26 Ah Sealed Lead Acid Battery - 12 Vdc 20(9.07) 12V40A 40Ah Sealed Lead Acid Battery - 12 Vdc 32(14.5 1) 12V50A 50 Ah Sealed Lead Acid Battery - 12 Vdc 165 40(18,14) 12V65A Ah Sealed Lead Acid Battery - 12 Vdc 49(22.23) Eow*ros SYTIMS TcHNol..eaY U&SALE& ePADENlON, FLA8B.378.2329; FtX8OB6O3-396 • CAPstMSALE& OMEN SOLR.ID, ON 519.3762430; FX 519.376-7258 lffrBlNATUNALE&5.20.1711; FAX9O5.270a553 • C0MRATEHEAuauARrm(:HEsHiMcr •. tx&K4wwAcFL=1MPrrTsnELD&NEWXMW ieaua 3 Literature. Sheet #85010-0127 Page 1 of 2 Nat to be uasd.Vor lrsiItIcn purpc.sa. For the most currant literature and updates .visit wwwat net S EDWARDS SYSTEMS TECHNOLOGY Itisois intention to keepihe product information currentand accurate. Wecan not cover specific applicalionsor anticipate all requirements. Al specifications aresubjecttochangewithoutnotice. For more information or questions relative tothis Specification Sheet, contact EST 02004 101 Printed in U.S (otin) Page 2 of 2 Literature Sheet #85010-0127 Issue 3 Not.to be used for installation purposes. For the most current literature and updates visit www.est.net. A product of EST Markedng,Bradsnton,FL Remote Annunciator Installation The RA-1000 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. Compatibility The RA-1000 is compatible with the following. FACPs: .IFP..1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel MEA 429-92-E Vol. IX RA-11000 F.arenhyt ... RA-1 000 The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA-1000's keypad and display match the built-in annunciator of the IFP-1 000 control panel. .The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons .for system reset and silence RS-485 interface to panel Operation and appearance is identical to IFP-1000 built-in annunciator Install up to eight RA-1000s per FACP Support for simultaneous use of multiple RA-1000s On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Available in red or light gray Wiring lengths up to 6000. ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved SILENT 7550 Meridian Circle Maple Grove, Mn 55369-4927 us KNIGHT 763-493-6455 1-800-328-0103 Fax: 763493-6475 by Honeywell httpI/www.renhytcom P/N 350071 Rev B. 05/04/05 Copyright © 2006 Silent Knight IFP-1000 FACP i,!k\ — RA-1000 RA1000 RA-1000 I — — S I I IlI Up to 8 RA-1000 per system .80 character backht LCD display (4 lines with 20 characters each) Wirrng lengths up to 6000 ft. from the control panel Specifications Environmental Physical Operating Temperature 32°F - 120°F (0°C - 49°C) Height 7.4" (18.8 cm) Humidity 10% - 93% non condensing Width 9.1" (23.1 cm) Approvals Depth: 1.5" (3.8 cm) NFPA72 Shipping Weight: 2.8 lbs (1.3 kg) Other Approvals: UL Listed; CSFM 71700559: 135; Color MEA 429-92-E Vol. IX; FM Approved . . .. . RA-1000R: Red . . . . . . . . RA-1000: Gray . . Ordering Information. . . . •. Electrical . . RA-1000R. Remote Annunciator. Four line LCD • . . Operating Voltage 24 VDC . annunciator with 20 characters per line. Red Standby Current 20 mA max RA 1000 Remote Annunciator. Four line LCD Alarm Current 25 mA annunciator with 20 characters per line Gray. Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) . Accessones 58601R Red Trim Ring. For surface mounting.. Max Per System: 8 . . . . . . 58601G Gray Trim Ring. For surface mounting. SILENT This document is not intended to be used for installation purposes. We try to keep our . KNIGHT D product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple L i41 Honeywell Grove,.Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. . . . . . • Made In the U.S.A. Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The !ntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation,.RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into Analog I Addressable an electronic signal Under normal Photoelectric Type conditions the status LED blinks Smoke Detector approximately every 15 seconds The SD505-APS is particularly indicating that the head is suited to detecting dense smoke communicating with the loop The typical of fires involving materials LED lights continuously during the such as soft furnishings plastic alarm period foam or other similar materials Features . which tend to smolder and produce la e visible pa rticles.' Low profile, 2 inches, including SD505-APS Smoke Detector. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software) Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. oase Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through thecontrol panel or remotely through a WindowsTM based computer software. Vandal-resistance locking. features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved Specifications Operating Voltage 17-41 VDC Current Consumption: • Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: • 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505-6AB (Sold Separately) (6" Base) 5D505-4AB (4" Base) DSILENT KNIGHT by Honeywell 4' Model SD505-APS• . . . Addressable Photoelectric Type . . ..... Smoke Detector Engineering Specifications . . . The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base 5D505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. . . . . . . . The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector: The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter 3-15116" 101 LOA 0 Di \ Height = 2 inches, I I I including base \ 4! 0 Model SD505-6AB Detector Base (front view) Model SD505-APS Detector Head (front view) D SILENT This document is not intended to be used for installation purposes. We ti to MADE IN AMERICA KNIGHT specific our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev c,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. Addressable Heat Detector lntelliKnight® addressable heat detectors combine accurate heat detection with pin-point location ID. An essential combination for any installation. lntelliKnight heat, detectors are an essential component in virtually any lntelliKnight installation. The lntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other lntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. _fl I1±L_ Model UbU-AMb IT me iemperature exceeas the trip Addressable Heat point (programmed at the panel), an alarm occurs. The status LED Detector lights continuously during the alarm The SD505-AHS is a heat detector period. suited to virtualy any commercial Under normal conditions, the status setting. The SD505-AHS is an LED blinks approximately every 15 absolute temperature device. This seconds, indicating that the head is means that it responds in alarm if communicating with the loop. the temperature goes above the trip point (programmed at the panel). The SD505-AHS provides accurate temperature measurement data to the fire alarm cDntrol panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505-AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to tie IntelliKnight panel. Features Low profile, 2 inches, including base Absolute temperature device Simple and reliable addressing Uses digital communication protocol The SD505-AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. CFSM listed MEA listed FM approved DSILENT KNIGHT by Honeywell SD505-AHS Heat Detector Specifications Operating voltage: 17 to 41 voc Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135°F to 150°F (57°C TO 65°C) Ambient Temperature: 329F to 12F (WC to 49C) Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70' between sensors on smooth ceilings. Compatible Bases: SD505-6AB (Sold Separately) (6" Base) S0505-4AB (4° Base) 5. Model SD505-AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS . The combination detector head, and twist-lock base, shall be ULP listed compatible with Silent Knight's lntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-AIS Ionization Smoke Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. Diameter= 5-15/16' Diameter = 3-15/16" ii -14 En Height = 2 inches. including base i S4UsT1 L... Model SD505-6AB Detector Base Model SD505-AHS Detector Head (Front View) (Front View) D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all - L%.IU%I11 specific applications or anticipate all requirements. All specifications are. FORM# 350229 Rev B,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. SD500-PS and SD500-PSDA Addressable Pull-Station lntelliKnight's addressable pull stations. combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this withthe features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA Addressable Pull Station The SD500-PS is a single action. addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an lntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed CSFM listed ADA compliant Key reset (Same key as Silent Knight enclosures) Surface mount back box available Terminals - accept up to 14 gauge wire Corrosion-resistant gold-plated contacts. Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby current: .55mA Alarm Current: .55mA SD500-PS Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB DSILENT KNIGHT .6. SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel) painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings. . . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FACP ' 1"r - 0 Mounting to Single Gang Electrical Box Ptl F H=. 71 Mounting to Optional Surface Mount Box r :. Wiring D r ac*PE4- Installing SD500LK Dimensions D SILENT . KNIGHT . . 7550 Meridian Circle, Maple Grove, MN 55369-4927 . .. MADE IN AMERICA 800446-6444 or in Minnesota 763-493-6435 . FORM# 350342, Rev. 09/03 FAX: 763-493-6475 World Wide Web: http:llwww.silentknight.com . . . copyright 0 2003 Silent Knight . ... . . Model SD500-AIM •• . . Addressable Input Module And . Model 0500-MIM IlL Miniature. Input Module lntelliKnight's addressable contact monitor modules combine fast response with pin-point location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight's lntelliKnight fire control panel. The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AlM addressable input module mounts to a 4-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. . . . . . . . The SD500-AIM and SD5007MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. Model SD500-AIM and SDSOO-MIM Input Modules The addressable input modules expand the flexibility of the lntelliKnight system by allowing the use of contact type inputs. Typical applications include manual pull stations and water flow switches. Features Operates on Class A (Style 6 & Style 7) or Class B (Style 4)SLC Loop. Single contact monitor. Up to 127 modules per SLC loop.. SD500-MIM mounts in a single gang box. SD500-AIM mounts in a 4"-square or dot..ble gang electrical box, and has an attractive ivory cover plate. SD500-AIM/MIM are DIP switch programmable. Accepts up to 14 gauge wire. Both modules UI. 864 listed; comply with NFPA 72 2500 ft max. wiring distance from input module to contact. CSFM listed. MEA 429-92-E, Vol. 9 FM approved r SDSOO-AlM Operation Each addressable input module is programmed with a unique SLC loop address. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. If a fault occurs in the wiring, the module alerts the FACP. DSILENT KNIGHT a 50500-MIM Spedflcatlons Operating Voltage: 24 VDC Mounting: •. SD500-AIM double gang box or • 4°-square electrical • • box SD500-MIM single gang box 7. Standby Current: 0.55 mA Alarm Current: 0.55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Model SD500-AIM and SD500-MIM Addressable Input and Mini Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MlM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs The 5D500-MlM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor.LED that is visible from outside the cover plate Model $0500-AIM FRONT VIEW BACK VIEW SIDE ViSli I. -- -•- •i•9*. - 1I4 Model $0500-MIM 2112" WI." • DSILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 • • • FORM# 350231, Rev. 11/01 FAX: 763-493-6475 • World Wide Web: http://www.siientknight.com Copyright 0 2001 Silent Knight Model SD500.ARM Addressable Relay Module Place relay applications anywhere on the IntelIiKnight loop with the SD500-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model SD500ARM . . . Features Addressable Relay Module The SD500-ARM provides two Form C contacts rated at 2A © 30 VDC or .6A @ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Two sets of Form C contacts. Contacts are rated at 2A @ 30 VDC or.6A@I2OVAC. Up to 127 relays can be used on each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions.. Polling LED visible through cover plate. UL listed, complies with NFPA 72. CSFM approved MEA Approved, 429-92-E, Vol. 9 FM approved o .......... ................ . ........... ............ Model SD500-ARM Speclftcatlons Contact Rating: Form C 2A @30 VDC .6A@ 120 VAC Standby Current: .55 mA Alarm Current: .55 mA SILENT KNIGHT Ambient 32°F to 120°F Temperature (0°C to 49°C) Mounting . 4-square electrical box 13 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright 0 2001 Silent Knight MADE IN AMERICA FORM# 350218, Rev. 11/01 Model SD500.ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. . . . . . . FRONT VIEW CAUTION REMOVE POWER PRIOR TO SERVICING 4-7/8" Model SD500.ARM Addressable Relay Module Dimensions DSILENT KNIGHT 1" AIR PRODUCTS AND CONTROLS You , in Control MR-1000, 200 SERIES MULTI-VOLTAGE CONTROL RELAYS PRODUCT DESCRIPTION W.W The MR Series Multivoltage Control Relays offer SPDT or DPDT 10 Amp resistive contacts which may be operated by one of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, I2OVAC or 23OVAC by wiring to appropriate input terminals. Each relay position contains a red LED which indicates the relay coil is energized. Relays -- may be "snapped apart" from a standard 4 module assembly and used independently. These Devices are Ideal for applications where local contacts are required for system status, remote 'W contacts for control of electrical loads and general purpose switching.They are suitable for - use with HVAC,Temperature Control, Fire Alarm, Security, Energy Management and Lighting Control Systems. '!- FEATURES j... Relays may be energized from a voltage source of 18 to 35VDC orVAC, 120VACor230VAC + Each relay position contains a red LED, which illuminates when the coil is energized.This provides a time saving device when checking an installed - •.._- - - system — no metering is required - Single, dual or triple relay modules may. be "snapped apart" from standard 4-position master + DC control inputs are polarized For continuous duty use at 24VAC, 24VDC or I 2OVAC U US (NOTE: Not intended for continuous duty use @ 230VAC) • Available in dust resistant enclosures with LED viewing port(s) LISTED + /C versions mounted in enclosures . . CSFM LISTED + ICIR versions with red covers for NYC and other uses -. IT versions come complete with track mounting hardware which facilitates MEA ACCEPTED installation in standard cabinets . • UL recognized relays rated at 10,000,000 mechanical operations RECOGNIZED COMPONENT UL listed as Control Unit Accessory WIRING. (TYPICAL FOR MODULE POSIT SPOT CONTACTS ONE 7A@28VDC,I0A(NO: 1bHP, NC: II8HP) IzovAc; 7A @ 230VAC ION) 16 III NC C NOS1 ' 0 MR-101 RELAY ENERGIZED - :9 0 I LED 1 I I =1 INPUT CONTROL • 15124 115 220• VOLTAGES 24(10-35)VDC@18mA —+ 24(1 0.35) VAC @18mA --*I N 230VAC @18mA __J_H! I20VAC4'I8mA Ll DPDT CONTACTS 7A @ 28VDC, ISA (NO: 11HP, NC: IIOHP) I20VAC, 7A@ . •iIIIIr%u IIJLII MR-201 RELAY I ENERGIZED— I I LED .I I I I I I. I__ INPUT iI1I: CONTROL •_0102411523O VOLTAGES 24(I845)VDC @4OmA —.* (—)_(+) 24(1 8.35) VAC @4CmA — AC. A I20VAC@40mA —+ N H 230VAC@40mA • .— U LI Distributed By: Air Products and Controls Inc. 1749 E. Highwood I A — Pontiac, Ml 48340 HALM A (248) 332-3900 Phone GROUP (888) 332-2241 Toll free (248) 332-8807 Fax COMPANY www.ap-c.com • •I PRODUCT SPECIFICATIONS ' I flJjt_gf IfltS#IIISI_ - IJ IVII..fl 1.dUIVI MODEL MODULE CONFIGURATION MOUNTED MOUNTED COVER FILE FILE FILE NUMBER: POSITIONS PER POSITION HXWXD HXWXD MATERIAL S3403 73-92-E 7300-1004 3.25" (82mm) MR-101/T 1 SPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-1011C 1 SPDT 5.125" (130mm) ABS94VO uoxx Vol. 14 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 UOXX7 ________ :101 Red _______ MR-I0l/C!R 1 SPDT ABS-94V0 Vol. 22 Plastic • 3.25" (82mm) MR-1041T 4 SPDT 8.50" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-1041C 4 SPDT 5.125- (130mm) 189a uoxx • 9.50" (241mm) 2.50" (63mm) CRS UOXX2 UOXX7 Vol. 14 :101 MR1041C!R 4 SPDT Red 18ga CRS 3.25" (82mm) MR201!T I DPDT 2.125" (54mm) UOXX2 :106 • 1.50" (38mm) Grey MR-2011C 1 DPDT 5.125" (130mm) ABS94VO uoxx Vol. 16 • 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 UOXX7 _______ :101 Red ______ MR-201/C/R 1 DPDT ABS-94V0 Vol.22 Plastic 3.25" (82mm) MR-204/T 4 DPDT 8.5" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-2041C 4 DPDT 5.125" (130mm) 18ga uoxx • 9.50" (241mm) 2.50" (63mm) CRS UOXX2 UOXX7 Vol. 16 :101 __________ _________ ____________ Red MR-204/C/R 4 DPDT 18ga • ___________ CRS COIL VOLTAGE: MR-100: 24(18-35)VDC. 24(18-351VAC. 120VAC. 230VAC MR-200: 24(18-35)VDC, 24VAC, 120VAC, 230VAC (Pull in voltage: 75% of nominal max. @ 25"C; Drop out voltage: 250A of nominal mm. @ 25"C) POLARIZED: DC input only I IkIrut'ATfm. ..... .1,. CURRENT REQUIREMENT: Per module position: MR-100 Series = 18mA/ MR-200 Series = 40mA CONTACT RATINGS: 7A @ 28VDC / iDA (NO:1/6HP, NC:1/8HP) @ I20VAC / 7A @ 230VAC CONTACT CONSTRUCTION: Dry Form "C" ENVIRONMENTAL: 32"F to 120"F (0"C to 49"C) @ 85% RH (@32"F), Non-condensing, Non-freezing WIRING: Solid or stranded; #12 to #22 AWG terminals IT VERSIONS: 3.5" wide, low profile plastic snap track provided with mounting screws IC VERSIONS: Backbox: 18ga CRS, plated with 1/2" conduit knockouts top and bottom "UOXX=Control Unit Accessories, System; 2=Component; 7=Certified for Canada NOTICE: The information contained in this document is intended only as a summary and is subject to change without notice. The products described have specific instructionalllnstallation documentation, which covers various technical, approval, code, limitation and liability information. Copies of this documentation along with any gen- eral product warning and limitation documents, which also contain important information, are provided with the product and are also available from Air Products and Controls Inc. The information contained in all of these documents should be considered before specifying or using the products. Any example applications shown are subject to the most current enforced locallnatlonal codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned misted equipment, should be consulted prior to any implementation. For further information or assistance concerning the products, contact Air Products and Controls Inc. Air Products and Controls Inc. reserves the right to change any and all documentation without notice. ©Air Products and Controls Inc. 2005 DS-RL-2 C050115 Models Available Strobes Red White S1224MC SI224MCW S1224MCP S1224MCPW S1224MCK SI224MCSP Horn/Strobes Red .. White P1224MC. P1224MCW PI224MCP PI224MCPW P1224MCK P1224MCSP Horns Red White H12/24 H12/24W H12/24K Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickCllckTm Synchronizable with MDL Sync.Circult' module Meets U1.1971, NFPA72, and ADA signaling requirements All strobe and horn/strobe models incorporate a new patented voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. 0 (9 USTED 71.25-1209:222 55512 S4011 7135-1209:223 FM MEA approved 12202E 3014150 12602E Product Overview Operates on either 12V or 24V SpectrAlert Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced fea- tures that Include the w:dest range of candela options available and the capability to Widest range of candela options: recognize and, self-adjust for either 12 or 24 volt operation. With an overall feature 12V: 15 and .15/75 candela set that combines performance, installation ease, flexibility, and a consistent, 24V: 15, 15/75, 30,75 110 candela aesthetically pleasing appearance, the SpectrAlert Selectable Output devices Easy candela selection provide both the innovation and efficiency synonymous with the SpectrAlert name. Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The select- able candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpectrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting, in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friencly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClick" feature. Such labor-savings features make wire connections simple and fast, further reducing instaLd cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be availabl; in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. 10. Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4" x 4" )c 11/2" back box or a single gang 2" x4' x l/s' back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync•Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between. a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor SyncsCircuit . listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal .3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16" X 411/16" X 2'/8" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Specifications Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5 x 55/i X 2/16" Strobe and horn/strobe with small footprint plate. 33/s-x 55/s x 2/l6 Horn with universal mounting plate 5 x 5/s" x 1/i6 Horn without mounting plate 215/16" X 5/16 x 1/i6 Operating Temperature (Indoor) . U.S. Patent Numbers 32°F to 120°F (0°C to 49°C) . 5,593,569 Maximum humidity (Indoor) 5,914,665 95% as tested per UL464 . 6049446 ' . '. Outdoor (K Series) Operating Temperature —40°F to 151°F (-40°C to 66°C) Outdoor rating NEMA 311 (per UL 50) Walk Test . Weight, horn only SpectrAlert horn/strobe and horn only 7.2 oz. work on "walk tests" with time dura- tions of 4 seconds or greater Voltages 12 or 24VDC and FWR1 unfiltered Weight, strobe and horn/strobe Operating voltage range 8.8 oz. 12V: &-17.5V; 24V: 16-33V Mounting . . . . Operating voltage range (with 4 x 4" X 11/2" or 2" x 4 x 1/s" . . Sync.Circuit module, MDL)2 standard boxes . 12V: 9-17.5V; 24V: 17-33V. Euii wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. The MDL causes a one-volt voltage drop in the notification appliance circuit. Table 1-A: SpectrAlert Strobe UL Max. Current Draw Candela Setting FWR Operating Current-Strobe (mA RMS) DC Operating Current-Strobe (mA RMS) 8-17.5V 16-33V 8-17.5V 16-33V 15 112 64 127 59 15/75 135 74 127 69 30 93 90 75 158 160 110 208 .209 Table 1-B: Horn UL Max. Current Draw Measurements (mA RMS) Selectable Horn Tones DC FWR. 8-175V 16-33V s-ii.sv 16-33V Temporal Low Electromechanical 15 23 13 23 3000 Hz Interrupted Volume 15 33 13 23 High Electromechanical 36 53 20 44 3000 Hz Interrupted Volume 43 57 21 40 Non- Temporal Low Volume Electromechanical 16 37 19 29 3000 Hz Interrupted 16 32, 18 33 High Electromechanical 38 49 46 49 3000 Hz Interrupted Volume 44 56 42 58 Table 1-C: I2VDC Horn/Strobe UL Max. Current Draw Measurements (mA RMS) Temporal Low Volume High Volume Candela Setting Electromechanical 3000 Hz Electromechanical 3000 Hz 15 111. . 111 112 112 15/75 127 . 127 126 129 Non-Temporal 15 113 112 114 115 15/75 128 128 130 134 Table 1-D: 24VDC Horn/Strobe UL Max. Current Draw Measurements (mA RMS) I Temporal Low Volume High Volume I I Explanation of Published Voltage, Current, and SPL Specifications In May 2004 Underwriters Laboratories changed standard UL 1971 to require that operating current measuremments are made using RMS (root mean square) instead of peak or average values. RMS measurements more accurately predict the power consumption of a device since they take into account the entire current draw profile including surge, repetitive surge, and peak values. The published RMS cur- rent is the maximum operating current of that device within its operating voltage range. This current maximum may or may not occur at the endpoints of the voltage range. Similarly, UL tests the audibility of devices in accordance with UL 464 by measuring them across the operating volt- age range to determine the minimum sound pressure level produced at any particular setting. During May 2004, UL also changed the way they list the voltage range of a device. All 12V products will be listed between 8 - 17.5V and all 24V products will be listed between 16 - 33V. Those devices are considered "regulat- ed' Any product that does not operate within these ranges will be listed as a "special application" with its operating voltage specified on the device. Notes Current draw for strobe-only products is shown in Table 1-A. Current draw for horn-only products is shown in Table 1-B. 12VDC 2-wire horn/strobe current is shown in Table 1-C. 24VDC 2-wire horn/strobe current draw is shown in Table 1-D. Current draw for other horn/strobe power supplies can be calculated by adding the strobe current in Table 1-A to the horn current in Table 1-13 from the chosen settings. SpectrAlert Strobe Candela Selections For strobe candela selection, adjust slide switch located on the rear of the product while watching the Viewing window on the side of the reflector. Permissible Candela Settings Candela Operating Voltage Setting i2V I 24V 15 OK OK 15/75 OK OK 30 OK 75 OK 110 OK SpectrAlert Horn Sound Measurements .(dBA) Selectable Horn Tones 8-17.5i/ 16-33V Temporal Low Volume Electromechanical 67 75 3000 Hz Interrupted 68 75 High Volume Electromechanical 71 80 3000 Hz Interrupted 72 81 Non- Temporal Low Volume Electromechanical 71 79 3000 Hz Interrupted 72 79 High Volume Electromechanical 76 84 3000 Hz Interrupted 77 86 Typical weatherproof mounting with universal plate Was Screw (4 total) Role WBB te 71Loc.Idng...b Gasket ConduIt Entrance P °ner DIP Switch Operation on P1224MC oGasket A0135-02 Factor, OFF ON Default DIP Switch Low II High 13 Temporal i.i I Non-Temporal Electromech. 11 I 3000Hz 00 Base (rear) A0I10-01D - - SpectrAlert Ordering Information Model Description P1224MC Selectable Output Horn/Strobe, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe, 12/24 volt, white P1224MCP Selectable Output Horn/Strobe, 12/24 volt, red, plain housing P1224MCPW Selectable Output Ham/Strobe, 12/24 volt, white, plain housing P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, outdoor PI224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, "FUEGO" housing 51224MC Selectable Output Strobe, 12/24 volt, red S1224MCW Selectable Output Strobe, 12/24 volt, white SI224MCP Selectable Output Strobe, 12/24 volt, red, plain housing SI224MCPW Selectable Output Strobe, 12/24 volt, white, plain housing S1224MCK Selectable Output Strobe, 12/24 volt, red, outdoor S1224MCSP Selectable Output Strobe, 12/24 volt, red, "FUEGO" housing Notes Model . Description H12/24 Horn, 12/24 volt, red H12/24W Horn, 12/24 volt, white H12/24K Horn, 12/24 volt, red, outdoor Accessories . MDL .. Sync.Circuit Module, red . MDLW Sync•Circuit Module, white MDLWA Sync 'Circuit Module, white, Canadian model S-MP Small Footprint Mounting Plate, red, for single- gang back box S-MPW Small Footprint Mounting Plate, white., for single- gang back box BBS Surface Mount Back Box Skirt, red BBSW Surface Mount Back Box Skirt, white D-MP Universal Mounting Plate (replacement), red D-MPW Universal Mounting Plate (replacement), white WBB Weatherproof Back Box All of these SpectrAlert products are designed for wall mount only. All outdoor models mast use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the -fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/ strobes are recommended for 20' x 20' rooms or less. . . System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5119- Fx: 85.22.736.6580 . Fx: 91.124.237.3118 Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor — Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 . Fx: 70.95.937.7983 0 2005 System Sensor. The company reserves the right to change product specifications without notice. A05-0325.008.9/05.#1526 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7170-0559:144 Page I of I CATEGORY: Control Unit (High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464• DESIGN: Models IFP-50 and 5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: RATING: INSTALLATION: IFP-50, 5700 7628 5860/5860 R/RA-1 000 5897 5496 5824 5865-3/5965-4 5880 5883 SD500-LIM 5D505-61 B RA-100 3158 5220 120 VAC Primary, 24 VDC Secondary Control Units EOL Resistor Annunciator Power Supply Power Module Serial/Parallel Interface LED Annunciator LED 10 Module Relay Interface Board Line Isolation Module Isolation Base Remote Annunciator Reverse Polarity Module Direct Connect Module In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when Used in conjunction with Model SKE- 360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25(CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E(CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912- 1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911- 1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:129 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Model S0505-APS analog addressable photoelectric type smoke detector with model SD505- 4AB and S0505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:149 Rev. 06-13-2006 U This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0559:127 Page 1 of I CATEGORY: Heat Detector LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove MN 55369-4927 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763)391-5464 DESIGN: Model SD505-AHS electronic fixed temperature heat detector (analog) with Models 5D505- 4AB and SD505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: MARKING: APPROVAL: XLF Electrical: 39.5 VDC Temperature Range: 134°F - 149°F In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical/temperature rating and UL label. Listed as heat detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7270-0410:147 Rev. 06-12-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2.006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:136 Page 1 of I CATEGORY Boxes/Pull Stations LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Model PS-SKSA and SD500-PS fire alarm pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:,; 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units For indoor use only. Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 'b.....' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0559:132 Page 1 of I Misc. Devices/Control Unit Accessories Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 Models SDSOO-FRCM, SD500-FRCM-4 Monitor Modules and Model SD505-ARM Relay Module. Models SDSOO-ARM, SD500-AIM, SD500-MIM Addressable Input Modules. Models 5D500-FRCM and SD500-FRCM-4 monitor modules provide inputs for a control unit communication circuit and one Style B (Class B) contact closure initiating device circuits. Models 5D505-ARM and SD500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SDSOO-AIM and -MIM provide additional input circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. SD500-FRCM, -FRCM-4, -ARM, -AIM, -MIM: 24 VDC S0505-ARM: 120 VAC, 30 VDC. In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7300-0410:145 *Rev. 06-13-2006 7Qi This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:101 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Air Products and Controls Inc., 1749 East Highwood, Pontiac, Ml 48340. Contact: Richard Steele (248) 332-3900 FAX (248) 332-8807 DESIGN: Models MR-101/C, MR-104/C, MR-201/C, MR-20IICX, MR-204/C, MR-2041CX, PAM-I, PAM-2, PAM-2X, PAM-3, PAM-4, PAM-SD, RlC-1, RlC-2, *RIc..3 *RIc..4 *MR..RIC..301 *MR..Rlc..305 *MRRIC401 and *MR..Rlc..405 relay modules. Models MR-101/C, -201/C and -201/CX may employ suffix -R or -S. *The MR-RIC series relay modules will employ IT, IC, or /C/R suffixes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. 'Rev. 03-01-2006 jew. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or - recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 21, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF.THE STATE FIRE MARSHAL FIRE ENGINEERING . BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 713571653:163 Page 1 of I CATEGORY: Audible Devices LISTEE: System Sensor, Unincorporated Div. of Honeywell Intl Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models P1224MC, PI224MCW, P1224MCSP, PI224MCSPW, PI224MCP, PI224MCPW, PI224MCK, and P1224MCWK combination horn/strobes with selectable candela. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: . Electrical: 8-33VbC/FWR 12/24 VDCIFWR Selectable :15cd, 15/75cd 24VDC/FWR . . Selectable.: 30cd, 75cd, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: •Listee's name, model number, rating, and UL label. . . APPROVAL: Listed as horn strobes for use with separately listed compatible fire alarm control units. Suitable for the hearing impaired application. For wall mount and indoor use only. with suffix .'K' are suitable for indoor or outdoor use with an operating temperature range of -40°C to + 66°C (-40°F to +150.8°F) when mounted on Model WBB. backbox NEMA type 3R enclosure rating Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to. manufacturers Installation Manual for details NOTE Formerly 7135-1209:223 Rev. *0292006 . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or '• recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: . JUNE 261 2006 : Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy . Program Manager . I .