HomeMy WebLinkAbout5966 LA PLACE CT; ; FA140008; Permit3/12/24, 2:46 PM FA140008 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 5966 LA PLACE CT Permit Type: FALARM Parcel No: 2120620600 Lot #: 0 Reference No.: Permit No: FAI 40008 Status: ISSUED Applied 3/7/2014 Approved: 3/25/2014 Issued: 3/25/2014 PC #: Inspector: Project Title: MAXLINEAR TI—THIS IS MANUALLY AND AUTOMATICALLY ACTIVATED FA SYSTEM. WILL FURNISH AND INSTALL A COMPLETE 24 VDC, CLOSED CIRCUIT, MICROPROCESSOR BASED, ELECTRICALLY SUPERVISED, ANNUNCIATED FA SYSTEM AS SPECIFIED ON THE PLANS. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO ALL CONTROL PANELS, POWER SUPPIES, SIGNAL INITIATING DEVICES, AUDIBLE AND VISUAL ALARM DEVICES, WIRE, AND ACCESSORIES REQUIRED TO PROVIDE A COMPLETE OPERATING SYSTEM. Applicant: STANDARD ELECTRONICS 9340 STEVENS RD SANTEE CA 619-596-9950 Owner: CAMPUS CARLSBAD L L C C/O NEWPORT NATIONAL CORP 1525 FARADAY AVE #100 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 474 L 0 474 0 about:blank 1/1 Ph: (619) 596-9950 Standard Iax (619) 596-8850 9340 Stevens Road I, Santee, CA 92071 C?, dO UC. #590876 Electronics BSISACO #AC01903 UI. Installer #S570-1 8tandardElectronics.us February 14, 2014 Revised 3/13/14 FA i 4Ooo SUBMITTAL SHEET PROJECT: Maxlinear TI Carlsbad The Campus 5966 La Place Ct. # 100, Carlsbad, CA 92008 ARCHITECT: ELEC.ENGR: ELEC.CONTR: K.D. Stahl Const. Group 13240 Evening Creek Drive # 302, San Diego, CA 92128 EQUIPMENT Fire Alarm ITEM QTY DESCRIPTION MODEL NO. DATA SHEET 1 7 12 Volt AH Sealed Lead Acid Batteries ES7-12 MK Battery 7100 Addressable FACP wl DACT w/19" cabinet 2 1 SFM#7 165-1703:0105 7100-ID-PNL FCI Remote Serial Annunciator, LCD Display 3 1 SFM#7300-1703:0106 LCD-7100 FCI Analog Photoelectronic Sensor 4 1 SFM#7272-1703 :0121 ASD-PL2F FCI 6" Base, Flanged for use with analog sensor 5 1 SFM#7300-1653:0109 B21OLP System Sensor Addressable Double Action Pull Station 6 1 SFM#7150-1703:01 19 MS-7AF FCI Addressable Monitor Module 7 36 SFM#7300-1703:0102 AMM-2F FCI Supplementary NAC panel 8 2 SFM#73 15-1637:0102 HPF24S8 Honeywell Ceiling Strobe, 12/24volt,red, multicandela 9 19 SFM#7125-1653:0186 SCR System Sensor Wall Strobe, 12/24volt,red, multicandela 10 5 SFM#7125-1653:0186 SR System Sensor Wall Horn/Strobe, 12/24volt, red, multicandela 11 12 SFM#7125-1653:0188 P2R System Sensor Ceiling Horn/Strobe 12/24volt, red, multicandela 12 23 SFM#7125-1653:0188 PC2R System Sensor 13 2.6K 2 conductor, 16 AWG, Unshielded, Jacketed D162F WCW 14 1.8K WCW 2 conductor, 12 AWG, Unshielded, Jacketed 122F 15 1 IP & Internet Dual Path Communicator Honeywell _____ SFM#7300-1645:0199 IPGSM-4G I Maintenance-Free Recha eable Sealed Lead-Acid Battery DIMENSIONS mm(inch) In F1 F2 (FAB1ON TAB NO. 107'(PATTON TAB NO. 200) rov Discharge Tine Vs.. DIsharge Current (20°C) iIUiIiiIIU!m iUUIEuIi1IIIII' uuuiuuuuiiii•i I r'ECIFICATIONS Nominal Voltage (V) 12V Nominal Capacity 20 hour rate (0.36A to 10.50V) 7.24 10 hour rate ( 0.72A to 10.50V) 6.84Ah 5 hour rate (1 .22A to 10.20V) 6.12Ah 1 C (7.2A to 9.60V) 3.24Ah 3C 21.6A to 9.60V) 2.52Ah Weight Approx. 5.39Lbs. (2.45kg) Internal Resistance (at 1KHz) 22 mQ Maximum Discharge Current for 30 seconds: 144A Maximum Discharge Current for 5 seconds: 288A Operating Temperature Range Charge 0°C (32°F) to 40°C (104°F) Discharge -15°C (5°F) to 50°C (122°F) cstorage -15°C (5°F) to 40°C (104°F) uiidrge Retention (shelf life) at 20°C (68°F) 1 month 92% 3 months 90% 6 months 80% Charging Methods at 20°C ( 68°F) Cycle Use: Charging Voltage 14.4 to 15.OV Maximum Charging Current: 2.16A Standby Use: Float Charging Voltage 13.50 to 13.80V Life expectancy: Cycle Use: 100% depth of discharge 200 cycles 80% depth of discharge 225 cycles 50% depth of discharge 500 cycles Standby Use: 3-5 years Case Material: ABS (Option : 94-HB & 94V-0 Flame Retardant Case Material) e 65±1(2.000.04) 1S1i1(5.B4lLG4) r i 1 a Terminal: Fl or F2 1 2 4 100 OT an 2 I 0010 OT I' hOT.s lscarge lime nor Battery 1631 South Sinclair Street • Anaheim, California 92806 Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:0105 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472 Contact: Brian Reynolds j446124 Fax (203) 484-7309 Email: bria!3pIds2honeyweII.com DESIGN: Model 7100 series fire alarm control unit. Used in conjunction with NetSOLO Broadband Voice Evacuation System (CSFM Listing No. 6911-0694:257) for high rise applications. Power-limited; non-coded, manual, automatic, local, auxiliary, central station, remote station, proprietary service, releasing device service, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: BSM.1; 1120-0783; Basic System Module BSM-2; 1120-0781; Basic System Module BSM-1 D; 1120-0782; Basic System Module with DACT BSD-2D; 1120-0780; Basic System Module with DACT CAOM; 1120-0763; Class A Option Module MCOM; 1120-0761; Municipal Module PTRM; 1120-0762; Printer Module 7100-EN-M-000r; 1120-0779; Metal Door 7100-EN-Back Box; 1120-0787; Back Box 7100-EN; 1120-0787; Enclosure 7100-TXA; 1120-0778; Transformer Assembly 7100-EN-P-Door; 1120-0779; Plastic Door 7100-TXA-240; 1120-0801; 240V Transformer Assembly INI-7100; INl-7100-UTP/-FO; Intelligent Network Interface RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Inc. Label APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. *Also suitable for high-rise applications. These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, *9th Edition Standard *Rev. 06-23-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-1703:0105 Page 2 of 2 NOTE: 1. For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 2. Combined with 7170-1703:117 FORMERLY: 7165-0694:219 *Rev. 06-23-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ,. the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Vs operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300.1703:0106 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: GAMEWELL-FCII2 Clintonville ad, Northford, CT 06472 Contact: Brian Reynold.(204) 484-6124 Fax (203) 484-7309 Email: brian.rey2J2honeyweII.com DESIGN: Model LCD-7100 remote serial annunciator. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote annunciator for use with separately listed model 7100 fire alarm control unit (CSFM Listing No. 7165-0494:219). NOTE: FORMERLY: 7300-0694:231 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION IMF I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1703:0121 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: GAMEWELL-FC112 CIintonvipRd, Northford, CT 06472 Contact: Brian ReynoId342Ci) 484-6124 Fax (203) 484-7309 Email: brian.reethoneyweIl.com DESIGN: Models ASD-PL2F, ASDPL2FR*, ASD-FILTREXF, ASD-PTL2F, and MCS-ACCLIMATE2F photoelectric smoke detector. Models ASD-PL2F and MCS-ACCLIMATE2F employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors when used in conjunction with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models ASD-PL2F and ASD-PL2FR are also approved for installations inside System Sensor duct detector housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. FORMERLY: 7272-1209:160 and 7272-0694:263 XLF: 7272-1653:0123 *Rev. 01-28-2010 fm , 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not :T an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of I CATEGORY: 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B40 :,B404B,B404BT, 13406131,B501, 1350113, 14506587-002, 13501131-1, B5OIBHT, B401 , IIP, BIIORLP, BIIORLP75O, BII2LP, BII4LP, BII4LPBT, BII6LP and B2IOLP detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1703:0119 Page 1 of I CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: GAMEWELL-FCII2 Clintonvi!jfrRoad, Northford, CT 06472 Contact: Brian ReynoId2O) 484-6124 Fax (203) 484-7309 Email: brian.reynØs2honeyweII.com DESIGN: Model MS-7j action fire alarm pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. NOTE: Formerly: 7150-0694:261 XLF: 7150-0028:0199 *Updated 09-08-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL G FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1703:0102 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: GAMEWELL-FCII 2 Clintonville Road, Northford, CT 06472 Contact: Brian Reynolds (204) 484-6124 Fax (203) 484-9D9' Email: brian.reynoIds2honeyweII.com DESIGN: Models AMM-4, *AMM4F AMM-2 and *AMM 2F monitor modules and Models AOM, AOM-2, AOM-2R, *AOM..2RF AOM-2S and *AOM.25F control modules. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules NOTE: FORMERLY: 7300-0694:178 XLF: 7300-1653:0103 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-1637:0102 Page 1 of I CATEGORY: 7315 - POWER UNITS LISTEE: HONEYWELL POWER PRODUCTS12 Clintonville Road, Northford, CT 06472 Contact: Vladimir Kireyev (203) 484-6277 F (203) 484-7309 Email: DESIGN: Models HPF24S6, HPF24S8, HPFF8, HPFF8E, HPFF8CM, HPFF8CME, HPFFI2, HPFFI2E, *HPFFI2CM and *HPFFI2CME power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as power supply/battery chargers for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 *Rev. 10-20-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct IVI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of I CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc-3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 3,7245 Email: trish.linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm V it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: tnsh.Iinhart@syste ensor.com DESIGN: Models Models P2- 3.P2R1 and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R,2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC41RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA.WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three- pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not IN an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0199 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@Honeywell.com DESIGN: Models iPGSM-COM, iPGSM-DP, and iPGSM-4G Internet and Digital Cellular Fire Communicators. Units are suitable for residential and commercial applications. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with *separately listed compatible commercial and residential fire alarm control units. Refer to listee's installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. iPGSM-COM, iPGSM-DP formerly listed in 7300-1645:0183. it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division t. FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. PROPERTY INFORMATION The Campus - MaxLinear Name of property: - - -. Address: 5966 La Place Court Suite 100, Carslbad, California 92008 Description of property: Offices/Storage Occupancy type: B. S-i - - -. ........ - . -. Name of property representative: Address: Phone: Fax: E-mail: Authority having jurisdiction over this property: Phone: Fax: E-mail: INSTALLATION, SERVICE, AND TESTING CONTRACTOR INFORMATION Installation contractor for this equipment: Standard Electronics Address: 9340 Stevens Rd, Santee, CA 92071 License or certification number: 590876 Phone: 619-596-9950 Fax: 619-596-8850 E-mail: office@standardelectronics.us Service organization for this equipment: Address: License or certification number: Phone: Fax: E-mail: - - - - A contract for test and inspection in accordance with NFPA standards is in effect as of: - Contracted testing company: Address: Phone: Fax: E-mail: Contract expires: Contract number: Frequency of routine inspections: DESCRIPTION OF SYSTEM OR SERVICE Fire alarm system (nonvoice) C] Fire alarm with in-building fire emergency voice alarm communication system (EVACS) o Mass notification system (MNS) [J Combination system, with the following components: 0 Fire alarm 0 EVACS 0 MNS 0 Two-way, in-building, emergency communication system El Other (specify): N/A - - - - - NFPA 72, Fig. 10.18.2.1.1 (p.1 of 12) Copyright Sr 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 3. DESCRIPTION OF SYSTEM OR SERVICE (continued) NFPA 72 edition: 2010 - - Additional description of system(s): -- - - - 3.1 Control Unit Manufacturer: FCI Model number: 7100 - ID 3.2 Mass Notification System This system does not incorporate an MNS 3.2.1 System Type: In-building MNS—combination In-building MNS—stand-alone 0 Wide-area MNS 0 Distributed recipient MNS Other (specify): 3.2.2 System Features: Combination fire alarm/MNS 0 MNS autonomous control unit 0 Wide-area MNS to regional national alerting interface Local operating console (LOC) 0 Direct recipient MNS (DRMNS) 0 Wide-area MNS to DRMNS interface Wide-area MNS to high-power speaker array (HPSA) interface 0 In-building MNS to wide-area MNS interface D Other (specify): N/A 3.3 System Documentation Z An owner's manual, a copy of the manufacturer's instructions, a written sequence of operation, and a copy of the numbered record drawings are stored on site. Location: 3.4 System Software 0 This system does not have alterable site-specific software. Operating system (executive) software revision level: CAM Works v. 3.10 -_________________ Site-specific software revision date: 06/02/2014 Revision completed by: Scott Hodson - DA copy of the site-specific software is stored onsite. Location:-- 3.5 Off-Premises Signal Transmission 0 This system does not have off-premises transmission. Name of organization receiving alarm signals with phone numbers: Alarm: Phone: Supervisory: . - Phone: Trouble: Phone: Entity to which alarms are retransmitted: Carlsbad Fire Dept Phone:-- Method of retransmission: Telephone If Chapter 26, specify the means of transmission from the protected premises to the supervising station: N/A If Chapter 27, specify the type of auxiliary alarm system: 0 Local energy 0 Shunt 0 Wired 0 Wireless NFPA 72, Fig. 10.18.2.1.1 (p.2 of 12) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 4. CIRCUITS AND PATHWAYS 4.1 Signaling Line Pathways 4.1.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: 0 Quantity: (See NFPA 72, Sections 12.3 and 12.4) 4.1.2 Pathways Utilizing Two or More Media Quantity: N/A . - Description: N/A 4.13 Device Power Pathways No separate power pathways from the signaling line pathway Power pathways are separate but of the same pathway classification as the signaling line pathway Power pathways are separate and different classification from the signaling line pathway 4.1.4 Isolation Modules Quantity: - 4.2 Alarm Initiating Device Pathways 4.2.1 Pathways Class Designations and Survivability Pathways class: N/A _____ Survivability level: N/A _______ Quantity: N/A ctio (See NFPA 72, Sens 12.3 and 12.4) 4.2.2 Pathways Utilizing Two or More Media Quantity: N/A Description: N/A 4.23 Device Power Pathways No separate power pathways from the initiating device pathway El Power pathways are separate but of the same pathway classification as the initiating device pathway Power pathways are separate and different classification from the initiating device pathway 4.3 Non-Voice Audible System Pathways 43.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: 0 - - - Quantity: 6 (See NFPA 72, Sections 12.3 and 12.4) 43.2 Pathways Utilizing Two or More Media Quantity: NA Description: N/A -- - - . - 4.3.3 Appliance Power Pathways No separate power pathways from the notification appliance pathway Power pathways are separate but of the same pathway classification as the notification appliance pathway Power pathways are separate and different classification from the notification appliance pathway NFPA 72, Fig. 10.18.2.1.1 (p.3 of 12) Copyright © 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 5. ALARM INITIATING DEVICES 5.1 Manual Initiating Devices 5.1.1 Manual Fire Alarm Boxes 0 This system does not have manual fire alarm boxes. Type and number of devices: Addressable: I Conventional: N/A Coded: N/A Transmitter: N/A Other (specify): N/A 5.1.2 Other Alarm Boxes 0 This system does not have other alarm boxes. Description: N/A Type and number of devices: Addressable: N/A Conventional: N/A Coded: N/A Transmitter: N/A Other (specify): N/A 5.2 Automatic Initiating Devices 5.2.1 Smoke Detectors 0 This system does not have smoke detectors. Type and number of devices: Addressable: I Conventional: N/A Other (specify): N/A Type of coverage: 0 Complete area 0 Partial area 0 Nonrequired partial area Other (specify): N/A Type of smoke detector sensing technology: 0 Ionization 0 Photoelectric 0 Multicriteria 0 Aspirating 0 Beam Other(specify): N/A - .................................................................................................... 5.2.2 Duct Smoke Detectors J@ This system does not have alarm-causing duct smoke detectors. Type and number of devices: Addressable: N/A -- Conventional: N/A - Other (specify): N/A Type of coverage: N/A -- ................. -. ... - Type of smoke detector sensing technology: 0 Ionization 0 Photoelectric 0 Aspirating 0 Beam 5.23 Radiant Energy (Flame) Detectors 0 This system does not have radiant energy detectors. Type and number of devices: Addressable: - N/A - Conventional: N/A Other (specify): N/A . Type of coverage: N/A - --------- .................................... 5.2.4 Gas Detectors 0 This system does not have gas detectors. Type of detector(s): .N/.A .................. ................ Number of devices: Addressable: N/A Conventional: N/A Type of coverage: N/A _I----------------------. -------------------- 5.2.5 Heat Detectors 0 This system does not have heat detectors. Type and number of devices: Addressable: N/A Conventional: N/A Type of coverage: 0 Complete area 0 Partial area 0 Nonrequired partial area 0 Linear 0 Spot Type of heat detector sensing technology: 0 Fixed temperature 0 Rate-of-rise 0 Rate compensated NFPA 72, Fig. 10.18.2.1.1 (p.4of12) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. ALARM INITIATING DEVICES (continued) 5.2.6 Addressable Monitoring Modules 0 This system does not have monitoring modules. Number of devices: I 5.2.7 Waterfiow Alarm Devices 0 This system does not have waterfiow alarm devices. Type and number of devices: Addressable: N/A Conventional: 1 Coded: N/A Transmitter: N/A 5.2.8 Alarm Verification O This system does not incorporate alarm verification. Number of devices subject to alarm verification: N/A Alarm verification set for N/A seconds 5.2.9 Presignal Number of devices subject to presignal: Describe presignal functions: JI_ 5.2.10 Positive Alarm Sequence (PAS) Describe PAS: N/A 5.2.11 Other Initiating Devices Describe: N/A N/A Ig This system does not incorporate pre-signal. 0 This system does not incorporate PAS. 0 This system does not have other initiating devices. SUPERVISORY SIGNAL-INITIATING DEVICES 6.1 Sprinkler System Supervisory Devices 0 This system does not have sprinkler supervisory devices. Type and number of devices: Addressable: N/A Conventional: I Coded: N/A Transmitter: N/A Other (specify): N/A 6.2 Fire Pump Description and Supervisory Devices 0 This system does not have a fire pump. Type fire pump: 0 Electric pump 0 Engine Type and number of devices: Addressable: N/A Conventional: N/A Coded: N/A Transmitter: N/A Other (specify): N/A 6.2.1 Fire Pump Functions Supervised o Power 0 Running 0 Phase reversal 0 Selector switch not in auto 0 Engine or control panel trouble 0 Low fuel Other (specify): N/A 6.3 Duct Smoke Detectors (DSDs) 0 This system does not have DSDs causing supervisory signals. Type and number of devices: Addressable: N/A Conventional: 32 Other (specify): N/A Type of coverage: Required Coverage of Supply Duct Work - Type of smoke detector sensing technology: 0 Ionization 0 Photoelectric 0 Aspirating 0 Beam 6.4 Other Supervisory Devices 0 This system does not have other supervisory devices. Describe: N/A NFPA 72, Fig. 10.18.2.1.1 (p.5 of 12) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. MONITORED SYSTEMS 7.1 Engine-Driven Generator 7.1.1 Generator Functions Supervised 0 Engine or control panel trouble 0 Generator running 0 Other (specify): N/A 7.2 Special Hazard Suppression Systems Description of special hazard system(s): N/A 7.3 Other Monitoring Systems Description of special hazard system(s): N/A ANNUNCIATORS This system does not have a generator. 0 Selector switch not in auto 0 Low fuel This system does not monitor special hazard systems. This system does not monitor other systems. 0 This system does not have annunciators. 8.1 Location and Description of Annunciators Location 1: Main Entry Location 2: N/A Location 3: N/A ALARM NOTIFICATION APPLIANCES 9.1 In-Building Fire Emergency Voice Alarm Communication System This system does not have an EVACS. Number of single voice alarm channels: N/A Number of multiple voice alarm channels: N/A Number of speakers: N/A Number of speaker circuits: N/A Location of amplification and sound-processing equipment: N/A Location of paging microphone stations: Location 1: N/A Location 2: Location 3: N/A 9.2 Nonvoice Notification Appliances 0 This system does not have nonvoice notification appliances. Horns: N/A With visible: 35 Bells: N/A With visible: N/A Chimes: N/A With visible: N/A Visible only: 24 Other (describe): N/A 9.3 Notification Appliance Power Extender Panels 0 This system does not have power extender panels. Quantity: 2 Locations: Electrical Room NFPA 72, Fig. 10.18.2.1.1 (p. 6 of 12) Copyright 02009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. MASS NOTIFICATION CONTROLS, APPLIANCES, AND CIRCUITS 10 This system does not have an MNS. 10.1 MNS Local Operating Consoles Location 1: N/A Location 2: N/A Location 3: N/A 10.2 High-Power Speaker Arrays Number of HPSA speaker initiation zones: N/A Location 1: N/A Location 2: N/A Location 3: N/A 103 Mass Notification Devices Combination fire alarm/MNS visible appliances: N/A MNS-only visible appliances: N/A Textual signs: N/A Other (describe): N/A Supervision class: N/A 103.1 Special Hazard Notification El This system does not have special suppression predischarge notification. El MNS systems DO NOT override notification appliances required to provide special suppression predischarge notification. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS 11.1 Telephone System 0 This system does not have a two-way telephone system. Number of telephone jacks installed: N/A Number of warden stations installed: N/A Number of telephone handsets stored on site: N/A Type of telephone system installed: 0 Electrically powered 0 Sound powered 11.2 Two-Way Radio Communications Enhancement System This system does not have a two-way radio communications enhancement system. Percentage of area covered by two-way radio service: Critical areas: N/A % General building areas: N/A % Amplification component locations: N/A Inbound signal strength: N/A dBm Outbound signal strength: N/A dBm Donor antenna isolation is: - N/A - - dB above the signal booster gain Radio frequencies covered: N/A Radio system monitor panel location: N/A NFPA 72, Fig. 10.18.2.1.1 (p.70f12) Copyright 02009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distilbution. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS (continued) 113 Area of Refuge (Area of Rescue Assistance) Emergency Communications Systems This system does not have an area of refuge (area of rescue assistance) emergency communications system. Number of stations: N/A Location of central control point: N/A - - Days and hours when central control point is attended: N/A Location of alternate control point: N/A Days and hours when alternate control point is attended: N/A 11.4 Elevator Emergency Communications Systems E] This system does not have an elevator emergency communications system. Number of elevators with stations: N/A Location of central control point: N/A Days and hours when central control point is attended: N/A Location of alternate control point: N/A Days and hours when alternate control point is attended: N/A 11.5 Other Two-Way Communication Systems Describe: N/A CONTROL FUNCTIONS This system activates the following control fuctions: E] Hold-open door releasing devices 0 Smoke management 0 HVAC shutdown 0 F/S dampers El Door unlocking 0 Elevator recall 0 Fuel source shutdown 0 Extinguishing agent release El Elevator shunt trip 0 Mass notification system override of fire alarm notification appliances Other (specify): N/A 12.1 Addressable Control Modules 0 This system does not have control modules. Number of devices: Other (specify): N/A SYSTEM POWER 13.1 Control Unit 13.1.1 Primary Power Input voltage of control panel: 120v Overcurrent protection: Type: Circuit Breaker Location (of primary supply panel board): Electrical Room Disconnecting means location: 13.1.2 Engine-Driven Generator Location of generator: N/A - -- - - - - - Location of fuel storage: N/A Control panel amps: 3.2A Amps: 20A This system does not have a generator. Type of fuel: N/A NFPA 72, Fig. 10.18.2.1.1 (p. 8 of 12) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 13. SYSTEM POWER (continued) 13.13 Uninterruptible Power System This system does not have a UPS. Equipment powered by a UPS system: N/A Location of UPS system: N/A Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): N/A In alarm mode (minutes): N/A. 13.1.4 Batteries Location: In FACP Cabinet Type: Lead-Acid Nominal voltage: 24v Amp/hour rating: 7AH Calculated capacity of batteries to drive the system: In standby mode (hours): 24 Hours In alarm mode (minutes): 5 MInutes Batteries are marked with date of manufacture 0 Battery calculations are attached 13.2 In-Building Fire Emergency Voice Alarm Communication System or Mass Notification System 10 This system does not have an EVACS or MNS system. 13.2.1 Primary Power Input voltage of EVACS or MNS panel: N/A EVACS or MNS panel amps: N/A Overcurrent protection: Type: N/A Amps: N/A Location (of primary supply panel board): N/A Disconnecting means location: 13.2.2 Engine-Driven Generator 0 This system does not have a generator. Location of generator: N/A .... Location offuelstorage: N/A Type offuel: N/A 13.2.3 Uninterruptible Power System 0 This system does not have a UPS. Equipment powered by a UPS system: N/A - - Location of UPS system: N/A Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): N/A In alarm mode (minutes): N/A 13.2.4 Batteries Location: N/A - Type: N/A Nominal voltage: N/A Amp/hour rating: N/A Calculated capacity of batteries to drive the system: In standby mode (hours): N/A In alarm mode (minutes): N/A 0 Batteries are marked with date of manufacture 0 Battery calculations are attached NFPA 72, Fig. 10.18.2.1.1 (p.9 of 12) Copyright 0 2009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 13. SYSTEM POWER (continued) 13.3 Notification Appliance Power Extender Panels 133.1 Primary Power Input voltage of power extender panel(s): 120v Overcurrent protection: Type: Circuit Breaker Location (of primary supply panel board): Electrical Room Disconnecting means location: 0 This system does not have power extender panels. Power extender panel amps: 3.2A Amps: 20A 133.2 Engine-Driven Generator This system does not have a generator. Location of generator: N/A - - - Location of fuel storage: N/A Type of fuel: N/A -- 1333 Uninterruptible Power System Z This system does not have a UPS. Equipment powered by a UPS system: N/A Location of UPS system: N/A Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): N/A In alarm mode (minutes): N/A 133.4 Batteries Location: IN NAC Panel Type: Lead-Acid Nominal voltage: 24v Amp/hour rating: 7A11 Calculated capacity of batteries to drive the system: In standby mode (hours): 24 Hours In alarm mode (minutes): _5 Minutes Z Batteries are marked with date of manufacture C] Battery calculations are attached 14. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checkedfor opens, shorts, groundfaults, and improper branching, but before conducting operational acceptance tests. This is a: 0 New system 0 Modification to an existing system Permit number: The system has been installed in accordance with the following requirements: (Note any or all that apply.) NFPA 72, Edition: 2013 NFPA 70, National Electrical Code, Article 760, Edition: 2011 Manufacturer's published instructions Other (specify): System deviations from referenced NFPA standards: Signed: Printed name: Jackie Matro Date: 06/02/14 Organization: S /ndard Electronics Title: Foreman Phone: 619-571-6853 NFPA 72, Fig. 10.18.2.1.1 (p. 10 of 12) Copyright 02009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 15. RECORD OF SYSTEM OPERATIONAL ACCEPTANCE TEST Z New system All operational features and functions of this system were tested by, or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements for the following. Modifications to an existing system All newly modified operational features andfunctions of the system were tested by, or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of the following: NFPA 72, Edition: 2013 NFPA 70, National Electrical Code, Article 760, Edition: 2011 Manufacturer's published instructions Other (specify): .-... -.--.--- Individual device testing documentation [Inspection and Testing Form (Figure 14.6.2.4) is attached] Signed: . Printedname:JacideMatro Date: 06/03/2014 Organization: S ndard Electronics Title: Foreman - Phone: 619-571-6853 - 16. CERTIFICATIONS AND APPROVALS 16.1 System Installation Contractor: This system, as specified herein, has been installed and tested according to all NFPA standards cited herein. Signed: .~)eec{. .4t.Jr94'\_ Printed name: Scott Hodson - Date: 06/03/2014 Organization: Standard Electronics Title: Project Manager -- Phone: 619-247-9433 16.2 System Service Contractor: The undersigned has a service contract for this system in effect as of the date shown below. Signed: Printed name: Date: Organization: Title: - Phone: 163 Supervising Station: This system, as specified herein, will be monitored according to all NFPA standards cited herein. Signed: - Printed name: Date: Organization: Title: Phone: NFPA 72, Fig. 10.18.2.1.1 (p.11 of 12) Copyright 02009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. 16. CERTIFICATIONS AND APPROVALS (continued) 16.4 Property or Owner Representative: I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: - - - Date: Organization: Title: Phone: 16.5 Authority Having Jurisdiction: I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, with its approved sequence of operations, and with all NFPA standards cited herein. Signed: Printed name: &j~ Vk -3 Date: Organiz&1WbM ff T J&4(f NFPA 72, Fig. 10.18.2.1.1 (p. 12 of 12) Copyright 02009 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution.