Loading...
HomeMy WebLinkAbout5966 LA PLACE CT; ; AS120028; Permit3/12/24, 2:53 PM AS120028 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5966 LA PLACE CT Permit Type: SPRINK Parcel No: 2120620600 Lot #: 0 Reference No.: PC #: Project Title: THE CAMPUS T.l. Permit No: AS120028 Status: PENDING Applied 3/1/2012 Approved: Issued: Inspector: Applicant: PACIFIC FIRE SYSTEMS, INC. 13142 NELSON LANE POWAY, CA 858-722-9865 Owner: CAMPUS CARLSBAD L L C C/O NEWPORT NATIONAL CORP 1525 FARADAY AVE #100 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 262 0 262 0 about:blank 1/1 Ast2zon MATERIAL DATA SUBMITTAL The Campus Building 5966 Suite #100 Tenant Improvement 5966 La Place Court Carlsbad, CA 92008 c. FIRE SYSTEMS INC. Pacific Fire Systems, Inc. 13142 Nelson Lane Poway, CA 92064 858-722-9865 Phone 9 866-318-6930 Fax tqC0 Fire Suppression & Building Products Technical Services 800-381-93121+1-401-781-8220 www.tyco-fire.com Series TYFRB — 28, 4.2,1 5.6, and 80 K-Factor Upright, Penden , and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2,5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coveraQe, decorative 3 mm glass bulb-tyC 1ighjt/6r ry sprinklers designed for use i ordinary hazard, commercial an- des such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, A two-piece Style 10 (1/2 inch NPT) or Style 40(3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet 77=P700 for the "INSTALLER WARNING" that provides cautions with respect to handling and Installation of sprinkler systems and components Improper handling and Installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TV- FRB Pendent Sprinklers is detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendant Sprinklers described herein must be Installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having Jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. JULY 2010 Model/Sprinkler Identification Number (SIN) TV1131: Upright 2.8K, 1/2- NPT 1Y1231: Pendent 2.8K, 1/2 NPT TY2131: Upright 4.2K, 112w NPT 1Y2231: Pendent 4.2K, 1/2 NPT 7.31-31Upright 5.6K, 1/2 NPT cJY3231:jPendent 5.6K, 1/2 NPT TY4t31 Upright 8.0K, 3/4 NPT TY4231: Pendant 8.0K, 3/4 NPT TV4831: Upright* 8.0K, 112 NPT 1Y4931: Pendent* 8.0K, 1/2 NPT 'Eastern HemIsphere Sales Only TFPI7I STYLE 10 or 20 RECESSED ESCUTCHEON TFPI7I Page 2 of 10 t 6* 5 7/16" 4 (11,1 mm) 2-1/4" I NOMINAL (57,2mm) 2 MAKE-IN 2-3/16" 1-9/16" (55,6 mm) WRENCH (39,7 mm) FLATS I 1/2" NPT SSP DEFLECTOR * -.--_ 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly * Temperature rating is indicated on deflector or adjacent to 2 - Button - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY.FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT SSU * DEFLECTOR 7/16"(11,1 mm) NOMINAL MAKE-IN 1 NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 7/16" (11,1 mm) SSU * NOMINAL DEFLECTOR MAKE-IN 6* t 7/16" I (11,1 mm) 4 I NOMINAL MAKE-IN _ 2 , 2-3/18" (55,6 mm) WRENCH FLATS 1/2" NPT CROSS SECTION UPRIGHT ESCUTCHEON PLATE SEATING iir SURFACE SSP DEFLECTOR* PENDENT STYLE 10 or 20 RECESSED ESCUTCHEON 2-7/8" (73,0mm) DIA. RECESSED PENDENT 1 - Frame 3-Sealing 4-Bulb 6-Deflector Assembly "Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT ('772131) AND PENDENT (TY2231) SPRINKLERS 42 K-FACTOR, 112 INCH NPT TFPI7I Page 3 of 10 7/16(11,1 mm) ESCUTCHEON STYLE 10 0r20 SSU * NOMINAL 1/2 PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 7/16 5 3/16 NOMINAL f (55,6 mm) 1 (11,1 mm)t ,, 2- MAKE-IN 2 2-3116" _______ (55,6 mm) FLATS 1-1/2° I _______ (38,1 mm) I 1/2° NPT SSP DEFLECTOR* 2-7/8° (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3-Sealing 4-Bulb 6- Deflector * Assembly Temperature rating is indicated on deflector or adjacent to 2- Button 5-Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV3131) AND PENDENT (f3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1/2' (12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU * NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5 1/2" 2J160 I (12,7 mm) 4 NOMINAL I ___________ (58,7 mm) MAKE-IN 2 2-1/4" 1-9/16" I I 3(57,2mm) (39,7 mm) I f 3/40 NPT SSP DEFLECTOR * L-_ 2-7/8"(73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3-Sealing 4-Bulb 6- Deflector Assembly "Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TYFRB UPRIGHT (TY4131) AND PENDENT (7Y4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT TFPI7I Page 4 of 10 7/16' (11,1 mm) SSU * NOMINAL DEFLECTOR MAKE-IN 1/2' NPT 6* ____________ i I _T 1 7/16' I (11,1 mm) _____________ 21/4" I NOMINAL (57,2 mm) 22_ __ MAKE-IN -3/16' 1-9/16' (55,6 mm) _____ WRENCH (39,7 mm) I FLATS ___ SSP*_- CROSS 1/2' NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 -Frame 3 - Sealing 4 - Bulb 6- Deflector 'Temperature rating Is Indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression Screw orifice seat on frame. FIGURE 5 QUICK RESPONSE SERIES TY.FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi'/2 (40,3 LPM/bar112) K=4.2 GPM/ps11l2 (60,5 LPM/barl 2) K=5.6 GPMIpsi1/2 (80,6 LPM/bar"2) K=8.0 GPM/psi'/2 (115,2 LPM/bart/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel w/Teflont Bulb ......................Glass Compression Screw........Bronze Deflector ........... Copper/Bronze Bushing (K=2.8) ...........Bronze t Registered Tradema,lc of Dupont Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard Installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval Is based on the requirements of FM's Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, Is to be used for recessed pendent Installations. Installation The TYCO Series TY-FRB Sprinklers must be Installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F/570C and 3/32 inch (2,4 mm) for the 2860F/141°C temperature ratings. Obtain a leak-tight 1/2 Inch NPTsprin- kier joint by applying a minimum to maximum torque of 7 to 14 ft.Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler filling to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Install Pendent sprinklers In the pendent position. Install upright sprinklers in the upright position. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Tipe 6 Sprinkler Wrench to the sprinkler wrench flats. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I WHITE I POLYESTER 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1I3I) 135"F/57°C Orange 1, 2, 3, 4 155"F/68°C Red 175°F/79°C Yellow 200°F/93"C Green 286"F/141°C Blue RECESSED PENDENT (TY1231)* Figure 6 135°F/57"C Orange 1,2,4 155"F/68"C Red 175°F/79"C Yellow 200°F/93"C Green RECESSED PENDENT (TY1231)** Figure 7 135"F/57°C Orange 1550F/68"C Red 175"F/79°C Yellow 200°F/93"C Green 4.2 1/2" NPT PENDENT (1Y2231) and UPRIGHT (TY2131) 135°F/57"C Orange 1,2 155"F/68°C Red 175"F/79°C Yellow 200°F/93°C Green 286"F/141"C Blue RECESSED PENDENT (TY2231)* Figure 8 135°F/57"C Orange 1550F/68°C Red 175"F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)** Figure 9 135°F/57°C Orange 155"F/68°C Red 175°F/79"C Yellow 200"F/93"C Green NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40(3/4" NP1) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLEA LABORATORY LISTINGS AND APPROVALS FOR 28 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I WHITE*** I POLYESTER LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F/68°C Red 175F/79C Yellow 200F/93C Green 286*F/141C Blue RECESSED PENDENT (TY3231)* Figure 10 1350F/57°C Orange 1, 2, 4, 5 Blue N/A 155F/88°C Red 175°F/79°C Yellow 200F/93C Green 288F/141C RECESSED PENDENT (TY3231)** Figure 11 1359F/570C Orange 1, 2, 3, 4, 5 Blue N/A 155°F/68°C Red 175F/79°C Yellow 20017/930C Green 286F/141°C 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (1Y4131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 - 155017/680C Red 1759F/79°C Yellow 200F/93°C Green 286°F/141°C Blue RECESSED PENDENT (1Y4231)* Figure 12 135°F/57°C Orange 1, 2, 5 N/A 155°F/68C Red 175F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)** Figure 13 135°F/57C Orange 1,2,3,5 Blue N/A 155°F/68C Red 175F/79C Yellow 2000F/93°C Green 286°F/141C - 80 1/211 NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135F/57C Orange 1, 2, 4, 5, 6 1, 2, 5 1550F/68C Red 1750F/79°C Yellow 200F/93C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories. Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FNfl as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MM 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board PCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-ResIstant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. __Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. -- Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME I WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT (1Y1231) and 28 UPRIGHT (TY1131) 1/2" NPT 75 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (TY3231) N/A PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) Only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. The Series TV-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler Into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TABLE C MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: were modified or over-heated. were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. are leaking or exhibiting visible signs of corrosion. were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. TFPI7I Page 8 of 10 2-7/8 DIA. - (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4' (6,4 mm) FACE OF (57,2 MOUNTING SPRINKLER PLATE FITTING 1/8 / (3,2 mm) /1 MOUNTING / SURFACE CLOSURE SERIES 1-5/16'( 33,3 mm) TY-FRB 13/16' (20,6 mm) FIGURE 6 SERIES 7Y-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 5/8±1/4" (73,0 mm) I (19,1 mm) I (15,9±6,4 mm) 2-1/4' DIA. I 1/4"(6,4 m FACE OF l I (57,2 mm) MOUNTING SPRINKLER - PLATE I FITTING 1/8" (3,2 mm) I \/I _ $ MOUNTING SURFACE SERIES 1-1/4"(31,8 mm) CLOSURE TY-FRB 3/4"(19,1 mm) FIGURES SERIES TY.FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 1/2±1/8" (73,0 mm) I 1/2' (12,7 mm) r (12,7±3,2mm) 2-1/4' DIA. 1/4" (6,4 mm) I FACE OF 57,2 mm) MOUNTING I I SPRINKLER / PLATE I FITTING I 1/8' I / (3,2 mm) I _______ $ MOUNTING / -5I16"(33,3 mm) SURFACE ,,,,, / { CLOSURE SERIES TY-FRB 1-1/16"(27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. - 1/2±1/8' (73,0 mm) I 1/2'(12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) I FACE OF (57,2 mm) MOUNTING / I SPRINKLER PLATE i FITTING 1/8' (3,2 mm) t I I \ MOUNTING I I SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE TY-FRB 1' (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility lies with the owner for the Inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service In accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. f \ MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) 1° (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. (73,0 mm) 3/4'(19,1 mm) 2-1/4° DIA. 1/4"(6,4 mm) I (57,2 mm) MOUNTING PLATE MOUNTING SURFACE 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1/2±1/8' (12,7±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8' DIA. (73,0 mm) 2-1/4° DIA. (57,2 mm) 1/2'(12,7mm) 1/4"(6,4 mm) MOUNTING - PLATE 1/8° (3,2 mm) t \ MOUNTING SURFACE TFPI7I Page 9of 10 2-7/8' DIA. (73,0 mm) 3/4' (19,1 mm) 5/8±1/4 - (15,9± 2-1/4' DIA. 6,4 mm) 1/4' (6,4 mm) I FACE OF ' MOUNTING mm _ SPRINKLER PLATE FITTING 1/8' (3,2 mm) / MOUNTING SURFACE , / CLOSURE SERIES 1-1/4° (31,8 mm) TY-FRB 3/4"(19,1 mm) FIGURE 10 SERIES TY.FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 1/2±1/8 (12,7±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8' DIA. (73,0 mm) I 1/2"(12,7 mm) 2-1/4° DIA. 1/4"(6,4 mm) I (572 mm) MOUNTING PLATE 7j CLOSURE SERIES 1-5/16° (33,3 mm) CLOSURE SERIES 1-6/16'(33,3 mm TY-FRB 13116"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END 'A' USED FOR 1/2' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4' NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 6 t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 10 of 10 P/N 57- XXX- X- XXX L FmODZ;IN] 330 2.8K UPRIGHT (1/2°NP1) TY1131 331 2.81< PENDENT (1/2°NPT) TY1231 340 4.21< UPRIGHT (1/2°NPI) TY2131 341 4.2K PENDENT (1/2°NPT) 1Y2231 370 5.61< UPRIGHT (1/2°NPT) TY3131 371 5.6K PENDENT (112"NPT) TY3231 390 8.01< UPRIGHT (314°NPT) 1Y4131 391 8.01< PENDENT (3/4°NPT) TY4231 360 8.0K UPRIGHT (1/2°NPT) 1Y4831° 381 8.0K PENDENT (1/2°NPT) TY4931° SPRINKLER I TEMPERATURE L FINISH RATINGS 1 NATURAL BRASS 135 135°F (57°C) 4 WHITE POLYESTER 155 155°F (68°C) 3 WHITE (RAL9010)' 175 175°F (79°C) 9 I CHROME PLATED 200 200°F 3°C) 7 I LEAD COATED I I 286 1 286°F (141°C) * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for It, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete Infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, Indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty Is made In lieu of any and all other warranties, exoress or implied, including warranties of mer- chantabilthLandlitness for a oarticular This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P(N). Sprinkler Assemblies with NPT Thread Connections Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. * Refer to Technical Data Sheet TFP770. Copyright 02007-2010 Tyco Fire Suppression & Building Products. All rights reserved. tqCD /Fire & Building I Products Technical Services: Tel: (800) 381-9312 1 Fax: (800) 791-5500 Series RFII 5,6 K-factor "Royal Flush II" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Series RFll Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K-Factor, Royal Flush II" Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the best choice for archi- tecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of sus- pended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the the Sprinkler provides for 112 inch (12,7 mm) of vertical adjustment, to reduce the accuracy to which the length of fixed pipe drops to the sprin- klers must be cut. The Series RFll Sprinklers are shipped with a Disposable Protective IMPORTANT Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING that provides cautions with respect to handling and Instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation Is complete the Protective Cap is removed and the cover Plate Assembly Installed. As an option, the Series RFll Standard Response (5 mm bulb) Royal Flush 11 Concealed Pendent Sprinklers maybe fitted with a silicone Air and Dust Seal (Ref. Fig. 5). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. WARNINGS The Series RFll Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, In addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3551 (5 mm bulb) bulb) JANUARY, 2008 Technical Data Approvals for Series RFll UL and C-UL Listed. FM Approved. NYC under MEA 353-01-E. LPCB (Ref. No. 094aI09 for TY3551 & 094a110 for TY3531) Approved. The approvals apply only to the serv-ice conditions indicated in the Design Criteria section. Approvals for Air & Dust Seal (Part #10908100) UL and C-UL Listed for use with the RFlI (TY3551) Standard Response Concealed Sprinkler. Maximum Working Pressure: Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC. Maximum 175 psi (12,1 bar) by FM and LPCB. Temperature Ratings 15517/68C Sprinkler - 135F/57C Plate 20017I93C Sprinkler - 165F/74C Plate Discharge Coefficient K = 5.6 GPM/psi1l2 (80,6 LPMIbarl'2) Adjustment 1/2 inch (12,7 mm) Finishes Cover Plate: Chrome Plated, Brass Plated, or White Painted (Custom paint matches and colors other than white are available on request.) TFPI8I .; Pagte2of4 TFPI8I 112' NPT SEALING ASSEMBLY FRAME CAP suor CUP WITH BULB ROLL FORMED - THREADS - COMPRESSION SCREW - GUIDE — PINS (2) DEFLECTOR (DROPPED DEFLECTOR H1- POSI11ON) SPRINKI.ERISUPPORT CUP I ASSEMBLY THREAD INTO U RETAINER SUPPORT CUP II WITh ThREAD UNTIL MOUNTING 0 0 DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING lL SPRING _ SOWER COVER TABS (3) COVER PLATEIRETAINER PLATE ASSEMBLY FIGURE 1 SERIES RFII CONCEALED SPRINKLER ASSEMBLY Physical Characteristics Frame ............Bronze Support Cup . Chrome . Plated Steel Guide Pins ......Stainless Steel Deflector ...........Bronze Compression Screw ......Brass Bulb ...............Glass Cap ........Bronze or Copper Sealing Assembly .......... Beryllium Nickel w/Teflon* Cover Plate ...........Brass Retainer ............Brass Ejection Spring. . . . Stainless Steel Patents U.S.A. 4,014,388 Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Retainer at three points, falls away to expose the Sprinkler As- sembly. At this point the Deflector sup- ported by the Guide Pins drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The RFII (1Y3551), 5 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as standard response - standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response - standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The RFII (TY3531) 3 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as quick response - standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response - standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The Series RFll Concealed Pendent Sprinklers are only listed and ap- proved with the Series RFll Concealed Cover Plates having a metallic or white painted finish. The Series RFll must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion In a fire situation. Installation The Series RFll must be installed in accordance with the following instruc- tions: !Ii4i Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C and 3/32 Inch (2,4 mm) for the 200°F/930C tem-perature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.Ibs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over-tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the RFll Sprinkler Wrench (Ref. Figure 3). The RFll Sprinkler Wrench is to be applied to the Sprin- kler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 4) by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent damage to the Deflector and Arms dur- ing ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Protec- tive Cap. NOTE As long as the Protective Cap remains in place, the system is considered to be "Out of Service". * Registered Trademark of DuPont \ -\__j L -------- I I 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE (4.8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (24 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4" (82,6 mm) C: 2-3/8" to 2-5/8" (60,3 to 66,7 mm) 3116"(4.8 mm) D: 1-3/4" to 2-114"(44,5 to 57,2 mm) FIGURE 2 SERIES RFII CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPi81 Page 3 of 4 FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING SPRINKLER SUPPORT CUP ASSEMBLY L!SIoNC 1/2" (12,7 mm) THREADED D ADJUSTMENT - I FACE OF CEILING I RETAINING RING I MOUNTING I SURFACE '771 FRAME ARM SUPPORT CUP IIMR IUL frji SQUARE ALIGN ARROWS WrrH FRAMEARMS ACCEPTS DRIVE FIGURE 3 RF11 SPRINKLER WRENCH Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and In prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal Is only to be installed on the periphery of the Re- tainer. Step S. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 5) contacts with the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembl y cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The Series RFll must be maintained and serviced in accordance with the following instructions: NOTES Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. . Page4of4 TFPIBI When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown In Figure 2. This air gap is necessary for proper opera- tion of the sprinkler. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system That it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it im- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec-tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accord- once with local requirements and/or national codes. Limited Warranty In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, Indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was Informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- pressor Implied. induding warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability a*hnr lanai •kaan, White (RALSOIO) 56-792-3-135 56-792-3-165 Bright White 58-792.4-135 56-792.4-165 Off White 56-792-6-135 58-792.5-165 Black 58-792.6-135 56-79241-165 Custom 56-792-X-135 56-792-X-165 For use with 166F/68C sprinlders. For use with 200F/93C spnnlders. * Eastern Hemisphere sales only Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. Products manufactured by Tyco Fire & " a"WN'U' ' Building Products (TFBP) are war- This warranty will apply to the full ex- ranted solely to the original Buyer for tent permitted bylaw. The invalidity, in ten (10) years against defects in mate- whole or part, of any portion of this rial and workmanship when paid for warranty will not affect the remainder and properly installed and maintained under normal use and service. This warranty will expire ten (10) years Ordering from date of shipment by TFBP. No Procedure warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP When placing an order, indicate the o r for products and components which full product name. Contact your local distributor for availability. have been subject to misuse, improper installation, corrosion, or which have Sprinkler Assembly: not been installed, maintained, moth- Specify: (SIN), (specify temperature fled or repaired in accordance with ap- rating) Series RFII Concealed Pen- plicable Standards of the National Fire dent Sprinkler, P/N (specify). Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found 165F168C 200F193C TIMM 51-790-1-155 51.790-1-200 by TFBP to be defective shall be either 51-792-1-155 51-792-1-200 repaired or replaced, at TFBP's sole Separately Ordered Cover Plate: option. TFBP neither assumes, nor Specify: (specify temperature rating) authorizes any person to assume for it, Series RFII Concealed Cover Plate any other obligation in connection with the sale of products or parts of prod- with (specify finish), P/N (specify). ucts. TFBP shall not be responsible for 13!57C(a) 165F174C(b) sprinkler system design errors or mac- Brass 56-192-1-135 56-792-1-165 curate or incomplete information sup- Bright Brass 56-792-2-135 56-792-2-165 plied by Buyer or Buyer's repre- Chrome 56-792-9-135 58-792-9-165 Brushed Chrome 56-792-8-135W792-8-165 sentatives. Wl,fa 0J4 56..79JL1 0 2114118 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 SMITH ,. COOPER <~@> INTERNATIONAL Ductile Iron Threaded Fittings C & US * ALL FITTINGS 1000/6 AIR TESTED * ASME/ ANSI B16.3 * ISO 900F.2000 MANUFACTURER * ASTM A536 Grade 6545,12 LISTED * LISTED/APPROVED AT 500 PSI * ASME/ ANSI B 1.20.1 pi'ciovo Thwfilp lynn Riill Uic1 Te Figure 35BT i 0 I .-A--a.t Lit Size A B I C 3/4x314x1 1.45 i& 17 0.68 I x 1 x 1-1/4 1.67 1.67 1.58 0.97 1x1x1-112 1.80 1.80 1.65 1.14 -114 x I x 1-1/2 1.88 1.80 1.82 1.43 -1/4x1-1/4x1-112 1.88 1.88 1.82 1.52 -1/4x1-1/4x2 2.10 2.10 1.90 2.00 -112x1-1/4x2 2.16 2.10 2.02 1.94 -112x1-112x2 2.16 2.16 2.02 2.00 2 x 2 x 2-1/2 260 260 2.39 3.67 fliwIi1 Irvn-n T1v R.ilii4na ('mIT1ino Figure 35RC size T WF II I I A 1 x 1/2 1.69 0.40 1x3/4 1.69 0.38 1-114x314 2.06 0.53 2 x 1(not hex) 2.81 0.53 Th.41D TW%YI 2,- fladiig'i,ia ('1Tic Figure 35X Size A I.1.. .!t -A•-*--A-. e 1 1.50 1.50 0.97 1-1/4 1.75 1.75 1.59 1-1/2 1.94 194 189 2 2.25 2.25 2.93 Figure 35 M Size A _B Wgt 1-1/4x1 1.67 1.58 1.25 1-1/2x1 1.80 1.65 1.48 2x1 2.02 1.73 2.64 Mirglp lrnn Phioi Figure 35SF Size T Wgt • I A 1/2 0.94 0.10 1 1.25 0.28 1-1/4 1.37 0.50 1-1/2 1.441 0.70 2 150090 .4.U,. Tw.,., P.,.n TD iaiire SRT Size A 1 0 C W 3M x 3/4 x 1/2 1.20 1.20 TT 0.46 I x 1/2 x I 1.50 1.36 1.50 010 1x314x3/4 1.38 1.31 1.45 0.68 I x 3M x 1 1.50 1.45 1.50 0.77 1 x I x 112 1.26 1.26 1.36 0.66 I x I x 3/4 1.38 1.38 1.45 0.73 1-1/4x1/2x1-1/4 1.75 1.53 1.75 1.04 1-1/4x 3/4 x1-1/4 1.75 1.62 1.75 1.09 1-1/4x 1 x1/2 1.341 1.26 1.53 1 0.81 -114x I x 3/4 1.451 1.38 1.63 0.90 -114x 1 x 1.581 1.50 1.69 1.03 -1/4xlx1-1/4 1.75 1.69 1.75 1.10 -114x1-1Mx1/2 1.34 1.34 1.53 0.87 1-1/4x1-1/4x3/4 1.45 1.45 1.62 0.96 1-1/4x1-114x1 1.58 1.581 1.67 1.10 i-1/2x1/2x1-114 IT i 1.7 1-1/2x 1/2 x 1-1/2 1.94 1.66 1.94 1.42 1-1/2x3/4x1-1/4 1.94 1.66 1.88 1.42 1-1/2x3/4x1-1/2 1.94 1.75 1.94 1.47 1-1/2x1x1/2 1.44 1.25 1.69 0.97 1-1/2x1x314 1.50 1.44 1.75 1.14 1-1/2xlx1 1.65 1.50 1.80 1.14 1-1/2x1 x1-1/4 1.821 1.67 1.88 1.47 1-1/2x1x1-1/2 1.94 1.80 1.94 1.52 1-1/2x1-1/4x1/2 1.41 1.34 1.66 1.03 1-1/2x1-1/4x3/4 1.52 1.45 1.75 1.10 1-1/2x1-1/4x1 1.65 1.58 1.80 1.31 1-1/2x1-1/4x1-1/4 1.82 1.75 1.88 1.52 1-1/2x1-1/4x1-1/2 1.94 1.88 1.94 1.50 1-1/2x1-1/2x1/2 1.41 1.41 1.66 1.14 1-1/2x1-1/2x3/4 1.52 1.52 1.75 1.23 1-1/2x 1-1/2x 1 1.65 1.65 1.80 1.38 1-1/2x1-1/2x1-1/4 1.5 x I x 2 2. 2 T! 2.18 x1-114x2 2.25 2.10 2.25 2.31 x 1-1/2 x 1/2 T T T5 2 x 1-1/2 x 3/4 '1.60 . TT TT x -1/2x1 1.73 1.65 2.02 1.65 2x -1/2x1-1/4 1.90 1.82 2.10 2.03 x ,-1/2 x 1-1/2 2.02 ..94 2.16 2.37 x 1-1/2 x2 2.25 2.16 2.25 2.53 2x2x1/2 1.49 1.49 1.88 1.50 x2x3/4 1.60 1.60 1.97 1.67 x2x 1 1.73 1.73 2.02 1.91 x 2 x 1-1/4 1.90 1.90 2.10 2.05 x2x1-112 r2.02 2.02 2.16 2.11 SMITH - COOPER <@> INTERNATIONAL <@> Ductile Iron Threaded Fittings ®us * ALL FITTINGS 100% A .3 TESTED *IE/&JSI B16 <<> * ISO 9001:2000 MANUFACTURER * ASTM A536 Grade 65,45,12 USTED * LISTED/APPROVED AT 500 PSI * ASME/ ANSI B 1.20.1 APPROVED Y)vjrH1p Trim QflO Plhnw Figure 35E : _____________ A _________ 1/2 1.13 0.24 3/4 1.31 0.40 ITg5 0.64 1-1/41.750.95 -1/2 1.94 124 [2E-1/2 .25 ].70 1.74 328 Ductile Iron Rediwine- 9fl0 Flhnw Figure 35RE size A T WT 3/4x112 1.22 1.20 0.33 xl/2 1.36 1.26 0.44 x314 1.45 1.38 0.53 -1/4 x1/2 1.53 1.34 0.64 -1/4x314 1.631 1.45 075 -1/4x1 1.671 1.58 0.77 -1/2 x 112 1.75 1.1 0.90 -1/2x3/4 1.75 1.52 0.95 -1/2x1 Täö T T -1/2x1-1/4 1.88 1.82 1.14 xl/2 1.97 1.60 1.35 x3/4 1.97 1.60 1.39 xl 2.02 1.73 1.58 xl-1/4 2.10 1.90 1.62 x 1-112 2.16 2.02 1.67 -1/2 x 1-1/2 1 2.51 2.16 2.32 2-1/2 x 2 1 2.60 2.39 3.01 ThwH1e Iron Brae Sp,fllninn Figure 35U Size T Wgt [L 111111 3/4 ti 1/2 TW 0.47 2.00 0.66 1 1-1/4 1-1/2 2.L ~j 2.03 3.151 2 - 1")iw441 Trnin Too Figure 35T T - ._ I 1/2 F T t 1.50 0.85 4 1.75 1.30 1-1/2 1.941 1.63 1 2 T2512.631 2-1/2 2.7014.55 Thwflla Tmii rnitinturicr Figure 35CP Size A .Y! III A III 1 1/2 1.38 0.18 3/4 .63 0.26 1 1.75 0.44 1-1/4 2 0.54 2.19 0.71 1 1-1/2 2 2.62 1.15 2-1/2 3.00 229 Ductile Iron ('an Figure 35C Size A 4 A J[ Tl 1/2 0.87 0.15 3/4 0.97 0.22 1 1.16 0.33 1-1/4 1.28 0.54 1-1/2 1.33 0.68 2 1.45 0.96 2-1/2 1.70 1.80 Thwfile Trim ller Riihino Figure 350B Size X WF II JI A 1x1/2 1.06 0.22 1x3/4 1.06 0.18 1-1/4 x 1 1.19 0.31 1-1/2x1 1.25 0.53 -1/2 x 1-1/4 125 0.35 2x1 Ti 0.75 2x1-1/4 1.38 0.69 2 x 1-1/2 1.38 0.62 Thii*ile Iron &c° Fllbnw Figure 35F Size T W - 4 /2 0.88 0.22 3/4 0.98 0.33 1.13 0.48 -1/4 1.29 0.73 1-1/2 1.44 0.931 2 1.69 1.55 2-1/2 I j. Ductile Iron Beam Clamns At Figure 35SP - Size A 3/8 0.75 0.31 1/2 Schedule;iiiiiiO'/Sch.edu1e.4O' Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-I0/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (11/"- 8") pipe and Sch-40 (1'L 2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Sch-40 Specifications UPS Nominal I.D. 01. WI. (H20 Filled) PoW WVLIft (21') Wt1Uft (24') WUU (25') In, mm In, mm 1.bs,fl Kghn Lbs.Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280. 1,334 1/i' 1.380 2.270 2.93 51 2,431 2,778 2,894 .32 35.1 4.36 4.36 51 1,103 1,260 1,313 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 216" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 11048 1,197 1,247 Sch-10 Specifications UPs Nominal I.D. WI WI. (H20 Filled) Pea/ WVLIII (21') WVIift (24') WIIUH (25') In; mm In, mm Lhsft,Kghn Lbsft,Kg4n Lift Lbs;Kg Lbs;Kg Lbs;Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 U. 1:442 1:810 ................61 2,319 2,664.........2;760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1W 1.682 2.080 3.04 61 2,664 3,045 . 3,172 40 42.7 . 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442- 50 54.8 3.9 6.28 37 930 1,063 1,108 2W . 2.635 3.530 5.89 . 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 .933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3. 17.53 . 19 1,015 1,160 1,209 5 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6' . 6.357 . 9.290 23.03 10 1,951 2.230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 . 209.5 24.5 59.75 . 7 1,100 1,256 1,309 Schedule-10/Schedule40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating Our advanced formula mill coating of- f'ers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, 'ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls,thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (NEC) when the First Sprinkler System is first installed. American ITMade Meets 'Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Schedule-10/Schedule-0 pipe are in compliance with the following: ASTMA-135,andNFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets . . . () <€i> (.j) Hydrostatic Pressure Side Wall . . Listed Approved Listed Vibration Test tqco/aow Control () ciffiecJ 16100 S. Lathrop Harvey, IL 60426 11350 Norcom Rd.' Philadelphia, PA 19154 Customer Service: (800) 882-5543 TUBE S CONDUIT . 2525 N. 27th Ave. ' Phoenix, AZ 85009 Fax 708-339-1806 S5-3 TOTC 10 Moon POflATeD CORONA. CA • (909) 737.5599 15 FIG. 2 ADJUSTABLE RING HANGER FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range - 1/2 thru 6 inch pipe. Material - Carbon Steel, Mu. Galvanized to C-gO specification. Function - For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approvals - Underwriter& Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 10, and Manufacturers Standardization Society SP-69, lype 10. Maximum Temperature - 650°F Finish - Mil. Galvanized and Stainless Steel. Order By. - Figure number and pipe size. f:?i PIPE ROD STOCK MAX. APPROX. WEIGHT PER 100 REC. FIG. 2 SIZE SIZE A B C SIZE LOAD LSS. FIG. 2 NFPA 1/2 3/8 3-1/8 2-5/8 1-3/8 169ax1 400 17 17 /L01 1 3/8 3-3/8 2-5/8 11/8 16gax1 400 18 18 £114 $J/.4 L7/ .400 1-1/2 3/8 3-7/8 2.7/8 1 16gax1 400 21 21 - 2 J/4 400 2-1/2 1/2* 5-3/4 4-1/4 1.5/8 149ax1.3/16 600 41 40 a 4/iL _A i/& . iJ4LL'3 / ]. 6 600 3-1/2 1/2* 7-3/8 5-1/4 2-1/8 14gax1-3/16 600 52 50 L L .i000 5 5/8 9 6-1/8 2-1/4 129ax1J/4 1250 97 95 12g/ 1250 kic' 3I& nut Is used when NFPA rod sizing is requested. "1/2" nut is used when NFPA rod sizing is requested, Size Range - 1/4. thru 1-1/2 inch rod in 10,-0" lengths. Material - Carbon Steel Maximum Temperature- 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel. Order By - Figure number, rod diameter, and finish. MAX. REC. LOAD LBS. APPROX. ROD FOR SERVICE TEMPS WEIGHT SIZE 650F 750F PER 100 FT. 1/4 240 215 12 1/2 1130- 1010 .53 Fhj 3/4 2710 2420 123 4960 4420 222 "I N1111 o 1-1/2 11630 10370 510 100 INCORPORATED CORONA. CA • (909) 737-5599 53 FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range - 3/8 thru 7/8 inch rod in 1 inch increments. Material - Carbon Steel Maximum Temperature- 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel. Order By - Figure number, rod diameter, rod length, and finish. MAX. REC. LOAD LBS. ROD FOR SERVICE TEMPS. SIZE 6507 750F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 FIG. 100 ALL THREAD ROD FULL LENGTHS SAMMYS® FOR WOOD us I,. 1k,,. No pre-drilling required. Quick to install using the Sammy Nut Dnver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. " fwbulldex.) i #14 Black Nut Driver Part # 8113910 1" #14 SW Red Nut Driver F'art#8114910 1/4" 8002957 GST 100 1/4 xl" 210 7/16"OSB) 1/4 8003957'GST-20 0 114x2 1760 (Fit) 1/4" 8004957 GST 300 1/4 x 3' 2060 (Fir) 3/8 8007957 (38110 114x V. 210 (7/18'OSB) 670 3/8' 8008957 GST 20 1/4 x 2' 1760 (Fir) 3/8' 8068925 GST2O.SS 1/4x2 1.760 (Fe) 3/8" 8009925 (38125.380 3/8x2-1/2' 2113 (Fir) 3/8 8010957 GST30 1140' 2060 (Fir) 3/8' 8069925 GST 3D-SS 1/4x3" 2060 (Fir) W. 8011925 GST40 114x4 2180 (Fir) 112" 8013925 GST2 1/4x2 1760 (Fir) 1/2 8014925 GST 25380 3!8x2 1/2' 2113 (Fir) 1/2" 8015925 GST3 1/4x3' 2275 (Fir) 25 125 2g... 125 25 125 '300 14 850 1475 25 125 850 .. .: 12 1500 25 125 1500. .1475, 25.• .125. 25 125 25 125 25 125 • .• 25.E 25 125 ITII :'7 (LH MADE IN U.S.A SECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each tine. When the face of the driver comes into co-tact with the malarial you are installing into, continue drilling until nut driver spins tree. Installation is then complete. Warranty requires the use of the appropriate nut driver for Installations. TO( ?R 1011~ I IICO R P0 RAVED 1.20 CORONA. CA- (909) 737-5599 FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range. - Pipe size to be braced: 1" through 8" Sch. 10 and 40. Pipe size used for bracing: I" and 1-1/4" Sch. 40 IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment com- ponent of a sway brace system: Fig. 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe p?r NFPA p13*, forming a complete sway brace assembly. Features - Can be used to brace Schedules 10 and 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided, to assure installer and inspector that necessary minimum torque (5 lb/it) has been achieved. Application Note - Fast Clamp reed not be field assembled. Position Fast Clamp and tighten two hex nuts until leaf spring flattens. *Length of bracing pipe per National Fire Protection Association, Pamphlet fl13, paragraph A-3-10.3.5: 1" Schedule 40 hracig pipe maximum 7-2". 1.1/4" Schedule 40 bracing pipe maximum 9-2". Approvals - Underwriters' Laboratories listed. Note - Must be used with Tolco U.L. Listed 900 Series attachment. Finish - Plain, Electro-Galvanized, HOG, and. Fig. 980 - Universal Swivel Sway Brace Attachment Size Range - One size fits bracing pipe 1 thru 2", TOLCO 12 gauge channel, and all structural steel up to 114" thick. Material - Carbon Steel Function - Multi-functional attachment to structure or braced pipe fitting. Features -This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.91 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. CUS LISTED Component of State of California OSHPD Approved Seismic Restraints System Installation -The Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 48 to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD. For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note - The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000, Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish - Plain Note Available in Electro-Galvanized finish. Order By - Figure number and finish. PATENT #6,273,372 - Dimensions 'Weights Max. Design Approx. /.•. 4i A B f ri Load Lbs. Wt1100 51/4 17/% 17/32 2765 132 * Available with hole sizes to accommodate up to C14' fastener. Consul factory. Lateral Brace TOLC07M brand bracing components are desgined to be compatible ONLY with other TOLCO"" brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO"' brand bracing components, in the instance that such TOLCO'" brand bracing components are used in combination with products, parts or systems which are not manufactured o r s o l d u n d e r the TOLCO"" brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFRCE/MANUFACTURING FACILITY. 1375 SAMPSON AVE. • COROitA, CA 92179. Pit: 951.737.5599" FAX: 951.737.0331) CUSTOMER SERVICE. 500.716.5266 www.tolco.com •••. .:.. . . cipë F o'/-D)~na F .`o v® I gh Strength Steel Pipe-, The original high-strength Iightwali sprinkler p i p e w i t h h y d r a u l i c s s u p e r i o r t o S c h e d u I e - .10. ) ollIecJ lUBE & CONDUIT (IUUffi IT-7, 73.177.171MIMI.ri Product Nominal Wt/Ft Wt/Ft PCs/ WI/Lift Wt/Lift Wt/Lift NPS I.D. H20 Filled Lift 21' 24' 25' X 1" 1.191 0.830 1.31 91 1586 1812 1888 *25 30.3 1.2 1.95 91 719 822 856 1 1/4° 1.536 1.059 1,87 Si 1356 1550 1615 *32 39.0 1.6 2.78 61 615 703 733 x 11/9" 1.728 1.667 2.71 61 2135 2440 2542 *40 43.9 2.5 4.03 61 968 1107 1153 x2° 2.20.3 2.104 3.79 - 37 1634 1868 1946 *50 56.0 3.1 5.64 37 741 847 883 2 1/2° 2.703 2.564 5.10 30 1615 1846 1923 *65 68.7 3.8 7.59 30 733 837 872 x3" 3.314 3.387 7.18 19 1351 1544 1608 *0 84.2 5.0 10.69 19 613 700 729 x 4" 4.310 4.473 10.86 19 1784 2039 2124 *90 109.5 6.7 16.16 19 809 925 963 X.6" 6,403 7.714 21.70 10 1620 1851 192 *150 162.6 11.5 32.29 t0 735 840 875 SuperFlo/Dyna-Fiow pipe is manufactured to meet- ASTM A- 795. Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. (@ 0 CS Listed Approved Listed Super Flo/Dyna-Flow is UL/ULC Listed for use with roll grooved, :P couplings, and welded. joints, for wet, dry, preaccion and deluge systems. Ic is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. SuperFlo/Dyna-Plow is now available "hot-dip"gal.vanized and has been specifically approved by FM for dry systems uses. Super Flo/Dyna-Fiow pipe is the "original high-strength Iightwall sprinkler pipe. Super Flo/Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Super Flo/Dyna-Flow is a valuable addition to any fire protection system. VA Superior Hydraulics With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, SuperFlo/ Dyna-How pipe hydraulics are exceptional. get I.D.s enable Super Flo/Dyna-Flow, d related components, to be down- sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to Super Fio/Dyna-Flow Hydraulic Data Tables." Coatings &Fabrication Super Flo/Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or wateibased coating. This durable coating is palatable. The black coating acts as an exceUent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent 'fabrication characteristics for end prep finishes, welding and roll grooving. No -sciai process or equipment are needed fabrication and 'ints]iaiioii. T Lightweight and easy to install, . resulting in inor, e.ftient use of your freight and labor. dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and .weid.ing,.as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" 'and, acts as art c.xccllent primer for custom paint applications. 16100 S. Lathrop 11350 Norcom Rd. 2525 N. 271h Ave. Customer Service: Harvey, It 60426 Philadelphia, PA 19154 Phoenix. AZ 85009 1-800-797-6210 Fax 70.R-339-1806