HomeMy WebLinkAbout3156 LIONSHEAD AVE; ; FA070015; Permit3/7/24,12:08 PM FA070015 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 3156 LIONSHEADAV Permit Type: FALARM Parcel No: 2218801200 Lot #: 0 Reference No.: Permit No: FA070015 Status: ISSUED Applied 2/1/2007 Approved: 2/6/2007 Issued: 2/6/2007 PC #: Inspector: Project Title: OPUS POINT 3, BLDG. 2 MONITORING SYTEM PLAN CHECK & INSPECTION Applicant: BERG ELECTRIC 650 OPPER ST ESCONDIDO CA 760-746-1003 Owner: OPUS WEST CORP 4350 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 117 0 117 0 about:blank 1/1 0700 J' CARLSBAD FIRE PREVENTION DIVISION Permit Application Form A. Check or fill in pertinent information for type 01' permit you are submitting. AS —Automatic Sprinklers (Check off type ofpIans being submitted) New System - How many risers/levels? Tenant Improvement Residential - How many systems and/or buildings? Underground for approval Underground included for reference only. FA - Fire Alarm 25 Devices or less V' Over 26 devices # of devices Monitoring System FS - Fixed Sj'stems (Circle One) Hood & Duct, Special Chemical Agent Suppression System, Standpipe, Spray Booth Repeated Inspection fee is $70.00. Total Fees r7 120 Total Fees Total Fees Name of Project: OPuS Poi i-c 1 L-o1.S 1-0 7 24 - iii..tj ,.j( 2- Address ofjob site: i.ioJSHEt ,4%dr Suite# Building Permit # CB C) ,O ( Contractor Information Name ( -E.CttZ4C Address W50 o°P4Z -i(L1 City, State, ZipScc*J bi (O A rIo2fl Phone FAX Kind of License and Number C- 10 W Exp. Date '7A6/0 -r Do you currently have a business license on file with the City of Carlsbad? or No Signature Date_______ Please estimate at least 10 business days for plan review comments and/or approval. We will contact you by telephone when the plans are approved/disapproved. Thank you! Permit Application Form.doc 08/23/2005 PAow (5_ Bergelectric Corp. actors & Engineers TABLE OF CONTENTS FIRE ALARM SUBMITTAL V V •4I: TAB Np. CONTROL PANEL INITIATING DEVICES NOTIFICATION APPLIANCES 3 BATTERIES 4 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 9 Fax (760) 746-4619 • CIO-#85046 Bergelectric Corp. actors & Engineers CONTROL PANEL 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 • C10485046 2H. EDWARDS SYSTEMS TECHNOLOGY Part of GE Security CONTROL PANELS QSC Conventional life safety control panel Features Supports up to 48 Class B or a combination of 40 Class A and Class B conventional circuits U Compatible with two- and four-wire smoke detectors U Failsafe mode ensures u ncom promised reliability U Capacity for eight remote annunciators U Four built-in system relays U Optional dual line dialer supports Contact ID and 4/2 formats U Three methods of programming: QuickStart"auto-learn," front panel and personal computer (PC) U Supports optional barcode scannerfor direct device data entry U Two optional banks of 30 front panel switches with dual LEDs U Red or grey cabinets in two sizes for surface or semi-flush mount- ing U Four-line (80 character) backlit LCD display U Four password levels, plus priority access keyswitch U Message routing by event type or by individual message U 1,000 event history buffer, plus alarm history counter U 6 amp Power Supply, 4.75 amps available for external use U ULC-5527-99compliant U Compare utility identifies system changes and simplifies testing. Description EST's QSC life safety control panel provides a cost-effective solution for conventional life safety applications. Designed for easy setup and simple installation. QuickStart lives up to its name in every respect QSC's exclusive QuickStort auto-learn function, and the option of configuring the panel using convenient front panel programming or from a PC, makes short work of system setup. Text entry is easy as well. A few simple passes of the optional scanner is all it takes to store custom messages. QSC's setup routine is deceptively simple, considering this system's robust features. Supporting up to 48 conventional Class B or a combina- tion of 40 Class A and Class B initiating circuits, this panel leaves plenty of room to grow. QSC is compatible with either two- or four-wire detectors, and also provides built-in support for EST's EC family of conventional detectors. QuickStart's modular design brings flexibility to every installation. Quick- Lok option cards snap onto QSC's easily-accessible DIN mounting rails. These cards provide a dialer, auxiliary relays and additional system capacity. QSC also supports as many as eight remote annunciators and up to 60 programmable front panel switches with dual LEDs for system control and display. QSC is as simple to operate as it is to set up. Its easy-to-read four-line backlit LCD display provides details concerning up to 1.000 system events, while bright system status LEDs and large, tactile control buttons present the user with a clean, crystal clear interface. Four password levels limit control and information retrieval to authorized personnel. A priority access keyswitch gives Level 2 access without a password to management and emergency personnel. Application QSC is a total life safety solution that merges flexibility, high system capacity, and robustfeatures with a cost-effective and installer-driven design. Ideal for small buildings. the QSC is perfectly suited for new and retrofit applications in schools, apartment buildings, hospitals, office buildings, and retail facilities. 0 at work Www.gesecurity.com 6985 TOWN CENTER PARKWAY, BRADENTON, FL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES: OWEN SOUND. ON 519-376-2430; FAX 519.376-7258 INTERNATIONAL SALES: (001) 905-270-1711; FAX (001)905-270-9553 Literature Sheet #85005-0112 Issue Not to be used for installation purposes. Page of 8 CT TO BE USE FOR FISTAL LATION PURPOSE Operation Indicators Controls Text display and controls: Displays system messages, status information, and programming menus. Arrow buttons move the display cursor. Alarm LED: Indicates afire or life threatening emergency. Supervisory LED: Indicates an off-normal condition with the fire suppression system or related equipment. Disable/Test LED: Indicates port of the system is disabled or being tested. Disabled components olso.signal a system trouble. S. Monitor LED: Indicates the operation of an ancillary system function (door closures, fan pressure switches). Trouble LED: Indicates on off-normal condition orwiring foultthat compromises the integrity of the system. Ground Fault LED: Indicates a ground fault in the system wiring. Ground faults also signal a system trouble. CPU Fail LED: Indicates on unexpected reboot or failure with the microprocessor. CPU failures also signal a system trouble. Power LED: Indicates the panel has power: Help button: Provides additional information about the device selected on the display. Status button: Displays the Status Menu from which you can identify active or disabled points in the system. Panel Silence/Acknowledge button and LED: Acknowledges all events posted in the display queues and turns off the panel buzzer. The panel silenced LED indicates that off normal events have been acknowledged. CPU / LCD Display The QSC front panel display provides four lines by 20 characters of text detailing event, device, diagnostic, and programming information. Its large backlit LCD screen is easy to read and always provides at-a- glance indication of the system's state of operation. The CPU/Display Unit houses the CPU card and mounting space for two optional LED/Switch cards. . ________ -00 I. Dl L&.J PIZ .............. .... .... Reset button: Allows devices or zones in alarm or trouble to restore to their standby condition. The LED indicates that the panel is resetting. Alarm Silence button:Turns active notification appliances off depending on panel programming. Pressing Alarm Silence o second time turns them bock on. The LED indicates that the panel is in alarm and operating with notification appliances turned off. Drill button: Activates notification appliances depending on panel programming but does not place the panel in alarm. The LED indicates that the panel is in Drill Mode. Menu button: Displays the operator menus. Delete button: Returns to the previous menu or backspaces the cursor. Enter button: Press the Enter button to accept information or continue to the next item. Numeric keypad: Numbered buttons for entering values and making menu selections. Barcode scannerjack: Input for optional barcode scanner. Priority Access keyswitch: Enables control functions reserved for access level 2 and above without requiring a password. Specifications Operating Temperature: 32-120°F (0-49 °C) environment Humidity: 93 %RH, non-condensing Current Standby: 117 mA when connected to PS6; requirements 105 mA when connected as a remote annunciator Alarm: 135 mA when connected to PS6; 123 mA when connected as a remote annunciator Failsafe Mode If the CPU loses communication with other circuit cards, the power supply card continues to monitor the system for any alarm events, if an alarm occurs on any device or circuit during a communications failure, the power supply activates all alarm outputs and instructs the dialer to transmit a default alarm message to the monitoring station. www.gesecurity.com Literature Sheet #85005.012 Issue 5 QSC Panel NOT TO BE USED FOR IN57ALIA1ION PURPOSES Typical Wiring Initiating Device Circuit - Class A Initiating Device Circuit - Class B Class B Notification Appliance Circuit with Genesis Signals and Signal Master for independent horn and strobe control and 2P Notification Appliance Circuit / - Class B with Separate Strobe I LEGEND Enhanced Integrity Genesis G Genesis 2 Smoke Manual Horn-Strobe Horn-Strobe M Signal Master Detector E Pull Station g suggestions can be found in the QSC Fire Alarm Control Pane! rt, Operation, and Maintenance Manual, P/N 3100185. www.gesecurity.com Issue 5 Uterature Sheet #85005-0112 Page 3of8 NOT IC BE USED FOR IITALATIC:N PURFO[; standard Components nd Option Cards All QSC panels come standard with a CPU/Display Unit, and a PS6 Power Supply (see ordering information for details). QuickStart option cards provide a wide range of features extra system capacity. Thanks to the convenient Quick-Lob mounting system, option cards snap onto the DIN mountir easily and securely. Waliboxes are available in two sizes room for either five or 12 single-space option cards. Both ofwallbox feature easily-accessible mounting rails and pie room for cabling. TA)R) C01M1'0NETT I PocverSippIiCarci.PW .e PS6 provides primary dc power to all the ;Ircuit cards installed in the cabinet There are four 24 Vdc power output circuits - three for powering auxiliary applications, and one for powering four-wire smoke detectors - and a charging circuit for standby batteries. The PS6 also provides common alarm, supervisory, and trouble relays, as well as a fourth relay that is user programmable. Ml? PIC NC AICPD Wiring MN,NM. NCNM.,,l TBZ lee oeeeezeeeezIooeelTB1 IC C IC C IC C IC C NO NM * - + - OTSIX ROCOM RCA?, RELAY, RCA?! RELAYI PCI! RuIN 2 Relay 1: Form c.contactschange position whenthe control panel processes onalarm signaland remain changed untilall active alarm inputs restore and the control panel resets. Relay 2: Farm A. Contacts change position when the panel processes a supervisory signal and remainschonged until all active supervisory inputsrestore. Relay 3: Form A. Contoctschange positionwhen the panel loses poweror processesa trouble signal and remainschanged until power returns or the trouble clears. Relay 4: Farm A. Relay closes ondopensaccording to panel programming. Smoke/Accessory Power. Jumpersetting determines if the 24 Vdc is constant or resettable. Specifications Main supply circuit AC input: 115 or 230 Vac, 50/60 Hertz DC input: 24 Vdc batteries Battery charging circuit Charge current: 2 amps Charge capacity: 40 amp hours (UL) 30 amp hours (ULC) Smoke/Accessory Voltage: 24 Vdc, regulated power output circuit Current: 250 mA Wire size: 12 to 18 (0.75 to 2.5 mm2) Auxiliary power Quantity: 3 Output circuits Voltage: 24 vdc full wave rectified Current: 1.5 amps each Common alarm relay Style: Form C Contact rating: 1 amp Wire size: 12 to 18 AWG (0.75 to 2.5 mm2) Trouble, Supervisory Style: Form A (NIO) and programmable Contact rating: 1 amp relays Wire size: 12 to 18 AWG (0.75 to 2.5 mm2) Operating environment Temperature: 32- 1200 F (0- 49° C) Humidity: 93 %RH, non-condensing Current requirements Standby current: 72 mA Alarm current: 96 mA www.gesecurity.com Page 4of8 . Literature Sheet #85005-0112 Issue Wiring (ZA8-2) TB loin I®®Oø®ø®®Iooøoo®®®®® +01 — ZONE 5 ZONES ZONE? ZONES NACIHRR +8 +8— +0 +A— +0— +8— +5 +8— ~~FWIR TB1 iLl] NOT TO BE UEI) 1('R INST Al. LATOI4 P1IRPOSE OFTO_NI C, A R, t) 'Zone Card t 2A8-2j The ZB16-4 Zone Card provides sixteen circuits ........ for connecting Class B conventional input and TB output zones. Twelve circuits are dedicated initiating device circuits (lDCs)for connecting 2- wire smoke detectors and dry-contact initiating devices. Four circuits can be configured as either lDCs or as notification appliance circuits (NACs) for connecting polarized 24 Vdc notifica- tion appliances such as horns or strobes. TBZ Wiring (ZB16-4) 210 217 ZIZ 213 ZII 210 210 RI 112 TBZ H H H H H H H L TB1 27 21 23 28 22 25 27 20 20 The ZA8-2 Zone Card provides eight circuits for connecting Class A conventional input and outputzones. Six circuits are dedicated initiating device circuits lIDCs) for connecting 2-wire smoke detectors and dry- contact initiating devices. The remaining two circuits can be configured as either lDCs or as notification appliance circuits lNACslfor connecting polarized 24 Vdc notification appliances such as horns or strobes. Specifications ZB16-4 ZA8-2 Initiating device circuits Quantity 12to16 6to8 Wiring configuration Class B Class A Detector voltage 19.9 - 24.0 Vdc, max ripple 400 mV End of line resistor 4.7k ohms, ½W Short circuit current 31 mA, max. Resistance 50 Ohms, max. Capacitance 100pF, max. NAC power input circuit Voltage 24 Vdc Wire size 18 to 12 AWG (0.75 to 2.5 mm2) Notification appliance circuits Quantity ito 4 =1 or 2 Wiring configuration Class B I Class A End of line resistor 10k ohms, ½W Output voltage 24 Vdc, nominal Output current 2.0 A, 24 Vdc Wire size 18 to 12 AWG (0.75 to 2.5 mm2) Operating environment Temperature 32-120° F (0-49° C) Humidity 93 %RH, non-condensing Current requirements Standby 123 mA 73 mA Maximum cards . in panel Three (48 zones) Five (40 zones) 40 zones maximum when both ZB16-4 and ZA8-2 cards installed. Card Spaces Requires two card spaces. The DLD is a ULI/ULC listed dual line Digital Alarm Commu- nicating Transmitter (DACT). It provides two phone line TB1 connections for sending system messages to a compatible Digital Alarm Communicator Receiver. The DLD supports 4/2 and Contact ID formats. It occupies one cord space on the chassis rail. SUOGE PRO.IEgOR RING 11 Wiring 'EENI TO Ill PHONE LINE 52 0.30 R PIN NODULAR FO CONNECTOR R PHONE USE Nil PHONE LINE 01 GREEN,WIREDSAUEAZ SPIN MODIJLAR tu I CONNECTOR FOR PHONE LINE 01 PREMISES NPHONES 9t SOT.TOPS PERMITTED I0000000011 TIP RING TIP RNG TIP RNG TIP RING IN OUT IN OUT LINE I LINE 2 Specifications Operating environment Temperature: 32 - 120°F (0-49°C) Humidity: 93% RH, non-condensing Current requirements Standby: 13 mA Dialing: 26 mA Phone Lines Two loop start lines on switched telephone network. Pulse or DTMF dialing. Wall Connector RJ31XJCA31A equiv. or RJ38XICA38A equiv. Communications Protocol Contact ID (SIA DC-05), 4/2 (SIA DC-02 P3). Programming Via QuickStart, Front Panel or PC. Communications Compliance Communications Canada CS-03FCC/CFR 47 Parts 15 and 68, NFPA 72, ULl 864, ULC S527-M87 Receivers Signals can be transmitted to either or both of two receivers. Telephone #s Two 24-digit numbers per receiver. Card spaces 1 Requires one card space. www.gesecurity.com Issue 5 Literature Sheet #85005-0112 Page 5 of 8 N011 10 BE USED FOR INSTALLATION PIJRFOSCS OPTION CARO FLED/Switch Cards SL30, SL3O-1 SL20L55, SL301..4 The SL30 and SL30-1 provide thirty circuits for zone annunciation. Each circuit comprises two LEDs and a button The SL30 button push switch. push switches are numbered from 1 t 30 and the SL30-1 push button switches are numbered from 31 to 60. The SL20L5S provides 20 circuits for point annunciation and five 400 circuits for custom control functions. The SL30L provides 30 circuits for point annunciation. SL20L5S i and SL30L circuits are labeled using inserts provided J with the cards. Specifications Operating Temperature: 32 - 120 F (0 - 49° C) environment Humidity: 93% RH, non-condensing Current Standby: imA requirements Alarm: 0.75 mA per active LED OPTION CP.PD- Relaj Card . . . . J,ZR8 The ZR8 provides eight dry-contact relays that can be independently configured as Form A or Form B .. TB1 relays. It occupies one card space on the chassis rail. Wiring RS- •RG- •R7- +R8- I0®®oøøoøl Ts. Y Y .. . .. ... . ..... . - Iøø0ø®®0®ITS' TB R1- +R2.- *R3- •R4- Specifications Output relays Style: Form A (N/O) or Form B (N/C) (jumper configurable) Contact rating: 1 amp © 30 Vdc resistive. Wire size: 18 to 12 AWG (0.75 to 2.5 mm2) Operating Temperature: 32- 1200 F (0-49°C) environment Humidity: 93 %RH, non-condensing Current Standby current: 7 mA requirements Alarm current: 18 ma per active relay Card spaces Requires one card space. OP lit) N PA laARS485 -Card andQS-232Pdj± The NT-A, which includes the X485/RS- 485 card and QS-232/UART port, provides one Class A serial remote annunciator bus for connecting remote annunciator panels. Control panels require the X485 card and OS- 232 port, which also serves as a laptop or printer port. The X485 occupies one card space on the chassis rail. The 05-232 port plugs into the panel CPU. )S-232 Specifications Wire size 12 to 18 AWG (0.75 to 2.5 mm2) twisted pair (6 twists per foot minimum) Circuit resistance 100 Ohms Circuit capacitance 0.4pF Operating environment Temperature: 32 - 120° F (0- 49° C) Humidity: 93 %RH, noncondensing Current requirements Standby: 75 mA Alarm: 75 mA Card Spaces Requires one space for the NT-A Wiring 012 011 www.gesecurity.com Page6of8 Uterature Sheet #85005-0112 issue 5 NoT 10 SE us):)) FOR INTALLATloN F'1'PPoSE Remote Annunciators The QSC front panel display provides four lines by 20 characters of text detailing event, device, diagnostic, and programming information. Its large backlit LCD screen is easy to read and always provides at-a-glance indication of the system's state of operation. The CPU/Display Unit houses the CPU card and mounting space for two optional LED/Switch cards. Remote annunciators connect directly to the PS6 Power Supply Card or an external 24 Vdc filtered supply.They are available - with wallboxes for flush or surface Remote annunciator (Class B wiring) Remote Annunciator Dimensions Model Height Width Depth QSA-1-S 7.6" (19.46 cm) 14.25" (36.20 cm) 2.9' (7.3 cm) QSA-1-F (rough in) 6.56' (16.66 cm) 13.25' (33.66 cm) 2.1' (5.33 cm) QSA-1-F (finished) 7.8 (19.81 cm) 14.42' (36.63 cm) 1.38' (3.49 cm) QSA-2-S 7.6' (19.46 cm) 18.56' (47.14 cm) 2.9" (7.3 cm) QSA-2-F (rough in) 6.56' (16.66 cm) 17.56' (44.60 cm) 2.1' (5.33 cm) QSA-2-F (finished) r 7.8- (19.81 cm) 18.75' (47.63 cm) 1.38' (3.49 cm) nougn.ln o,mens,ons reriect me size or inc caoiiet wnei'e it enters inc wall. Finished dimensions reflect the size of the cabinet that protrudes from the wall. Cabinet Mounting 12 and 5-Option Cabinets 2.2' (5.6 cm) Optional Vandal- Resistant Door 1.68' (4.27 cm) Well -] Ni Semi-flush Surface Mounting Mounting Semi-flush mounting requireson optional trim ring, which adds N (19 mm) to olisidesof the paneL Cabinet Dimensions '6 8 , I5' (45.72 mc) 0 0 18.513' (47.31 m) 5-Option Cabinet QSC-5-R-1 (red); QSC-5-G-1 (grey) a L111T11T.I. IiII--- 0 0 0 0 0 I (47.31 mcj 12-Option Cabinet QSC-1 2-R-1 (red); QSC- 12-G-1 (grey) www.gesecurity.com Issue 5 Literature Sheet #85005.0112 Page 7 of 8 NOT TO BE USED FÜR INtIAt L-AT ION P1'O5t. Ordering Information Part Description Ship Wt. Number lb. (kg.) Basic Package - Enclosure, Power Supply. CPU and Display QSC-5-G-1 Conventional System. Five option card spaces. 17.0 Gray. 115v transformer. (7.71) QSC-5-R-1 Conventional System. Five option card spaces. 17.0 Red. 11 5v transformer. (7.71) QSC-12-G-1 Conventional System. 12 option card spaces. 30.0 Gray. 115v transformer. QS-Cable12 required. (13.61) QSC-12-R-1 Conventional System. 12 option card spaces. 30.0 Red. 11 5v transformer. QS-Cable12 required. (13.61) Enclosure Accessories QS-2-VR Vandal-resistant cabinet door, gray 3.0(1.36) QS-2-VR-R Vandal-resistant cabinet door, red 3.0 (1.36) QS-Cable12 Expansion Cable for 12-option card cabinets. 0.5 (0.23) Trim-5 Gray Flush mount trim ring for QS-5-G-1. 5.0 (2.27) Trim-513 Red Flush mount trim ring for QS-5-R-1. 5.0 (2.27) Trim-12 Gray Flush mount trim ring for QS-12-G-1. 8.0 (3.63) Trim-12R Red Flush mount trim ring for QS-12-R.1. 8.0 (3.63) Initiating/Notification Circuit Option Cards ZB16-4 Conventional Zone Card. 16 Class B circuits, four convertible to Class B NACs. 2.0 Requires two option card spaces. ZA8-2 Conventional Zone Card. Eight Class A circuits, two convertible to Class A NAC's. 2 0 Requires two option card spaces. Other Option Cards DID Dual Line Dialer. Supports 4/2 and Contact ID 1.0 formats. (0.45) Relay Card. 8 programmable Form A contacts. 1.0(0.45) .Jisplay Options SL30 Annunciator module. Numbered 1 t 30. 1.0 Two LEDs and one switch per zone. (0.45) SL30-1 Annunciator module. Numbered 31 to 60. 1.0 Two LEDs and one switch per zone. (0.45) SL20L5S Annunciator module. 20 circuits for point annunciation, 5 circuits for custom functions. 1 Circuits labeled with insert card. 0 SL30L Annunciator module. Circuits labeled with insert card. 1.0 (0.45) QSC-CPU-1 Conventional CPU/Display. 4.0 One annunciator option space. (1.81) QSC-CPU-2 Conventional CPU/Display. 4.0 Two annunciator option spaces. (1.81) NT-A RS-485 option card. Required for Class A 1.0 remote annunciation. Includes UART card. (0.45) QS-232 UART option card. Plugs into CPU. Required for PC Programming / printer port. 1 0 Included _in_NT-A_package 045 Part Number Description I Ship Wt. I lb. (kg.) Remote Annunciator Cabinets (c/w Interface Assembly; Require CPU/Display) QSA-1-S Surface Remote Annunciator Cabinet. Space for one _SL3O_display. 40(1 81) QSA-i-F Flush Remote Annunciator Cabinet. Space for one _SL3O_display. 4.0(1.81) QSA-2-S Surface Remote Annunciator Cabinet. Space for two _SL3O_displays. 5.0(2.27) QSA-2-F Flush Remote Annunciator Cabinet. Space for two _SL3O_displays. 5.0(2.27) Programming Tools QS-CU QuickStart Panel Configuration Utility. 1.0(0.45) OS-Scan QuickStart scanner and programming guide. 2.0 (0.91) 260097 Programming cable (PC to QSC, 051, 0S4) 1.0 (0.45) 360136 Programming cable (PC to Annunciators) 1.0(0.45) 240507 lDB9 to RJ-ii (required with 360136) 1.0 (0.45) Accessories PT-iS SystemPrinter - Desk top Style 14.0 (6.35) BC-1(R) __________ Battery Cabinet. Room for one 40 Ah or two 24 Ah batteries. 22.0 (9.98) MFC-A MultiFunction Cabinet. 7.0 (3.1) IOP3A RS-232 Isolator Module. 3.0 (1.36) RPM Reverse Polarity Module. 3.0 (1.36) 2-CTM City Tie Module. 1.0 (0.45) API-8/232ME Alphanumeric Pager Interface 11.0(5.0)' BPS6 6.5 Amp Booster Power Supply, 110 V 13.0 (5.9) BPS10 110 Amp Booster Power Supply, 110 V 13.0 (5.9) CDR3 JPSNI Coder Module 1.0 (0.45) Ordering options (Apply to basic packages and CPU/displays only) Languages Power Supplies No suffix = American English 1 = 115v transformer SP = Spanish (230v or 115v) 2 = 230v transformer PG Portuguese (230v only) FR = French Canadian (120v only) Colors G = Grey enclosure 1230v or 115v) R = Red enclosure 1115v only) Examples QSC-5-G-2-SP = QSC basic package with five option cord spaces, grey enclosure, 230v transformer, Spanish language. QSC-CPU-2-FR = QSC CPU/display, two annunciator option spaces, French Canadian. Which Quickstart Panel is right for you? QSC QS1 QS4 Signature Series devices supported 0 1 x 250 4 x 250 Conventional Class B circuits supported 3 x 16 0 3x 16 Conventional Class A circuits supported 5 x 8 0 5 x 8 LCD display (lines x characters) 4 x 20 14 x 16 14 x 16 Optional Zone Switch/LEDs on front panel 2 x 30 1 x 30 2 x 30 Option card spaces 5 or 12 1 5 or 12 For more information, see catalog sheet number... This Sheet 85005 -0113 85005 -0114 www.gesecurity.com It is our intention to keep the product information current and accurate. We can not cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information or questions relative to this Specification Sheet, contact GE Security. © 2004 GE Security Printed in U.S.A. Page 80f8 Uterature Sheet #85005-0112 Issue 5 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:207 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models QSC, -QSi and -QS4 fire alarm control units, followed by —1 or —2 followed by -BR, -SP, - FR, -PG or no suffix. Local, local with shunt, auxiliary, remote station, releasing service or central station. Power limited. Non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterfiow, and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System Components: QSC, QSI, QS4 7200001-01, -02; 7200004-01, -02 7200005-01, —02 PS6 ZB16-4 ZA8-2 DLD ZR8 NT-A Q5232, 232 SL3O SL-30-1 SLIC QS-1-VR, -R, QS-2-VR, -R SL3OL SL2OL5S Control Units Enclosures Enclosures Power supply Class B zone card Class A zone card Dialer (DACT) card Relay card Class A, RS485 communications card Port for download or printer functions LED/Switch card with switch 1-30 LED/Switch card with switch 31-60 Signature expansion loop card. Vandal resistant doors LED Cards 30 Zones LED/Switch Cards 25 Zones RATING: INSTALLATION MARKING: APPROVAL: NOTE: 120/220 VAC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Units can also generate the temporal code pattern fire alarm signal as required per NFPA 72, 1999 Edition. Refer to listee's Installation Instruction Manual for details. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Formerly 7165-1591:207 and 7165-1388:237 O8-17-O5KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. Contractors & Engineers INITIATING DEVICES 650 Opper Street 9 Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 9 C 1048504 EDWARDS SYSTEMS TECHNOI.OGV Part of GE Security Ill.] E] Low-profile Plug-in Photoelectric Detector EC3OU-3 Features U Sensitive to visible and invisible products of combustion Finely tuned to sense all fire types, especially slow burning, smolder- ing fires fuelled by combustibles typically found in modern multi-use buildings. U Stable, reliable design Uses the light scattering principle for smoke detection and is not affected by air movement U Non-polarized Simplifies installation of field wiring U Simple to install, difficult to vandalize Twist-and-lock design saves installation and maintenance time. Field- configurable locking mechanism prevents unauthorized removal. U Flexible mounting options Compatible standard base mounts to 1-gang, 4' octagonal. BESA, or European single-gang boxes. U At-a-glancealarm indication An on-board high-intensity LED glows bright red when the unit is in alarm, making alarm response a simple and straightforward opera- tion. U Easytomaintain Removable housing and insect mesh facilitatescleaning. U Attractive appearance with clean, modern lines Low-profile design blends easily with surroundings, extending less than 21/2' (61 mm) from the ceiling, including base. Description EC30U-3 low-profile plug-in photoelectric detectors measure-up to the quality and performance standards that have mode GE Security fire detection products the industry's best price-performance buy available today. Meticulously engineered to deliver high-performance features, superb reliability, and unbeatable quality, the EC30U-3 is a low-cost solution for conventional detection applications. The EC30U-3 distinguishes itself as a performance leader in its class with its highly stable design that resists air movements caused by heating and air conditioning. and changing environmental conditions. This makes it reliable performer ideally suited to modern building interiors. The installation and maintenance advantages of the EC30U-3 add value to this detector throughout its service life. Its twist-and-lock design makes shortwork of installation and maintenance operations. A plastic breakout on the detector housing optionally prevents removal from the base except with a special tool. A bright, easy-to-see LED on the detector glows steady when it is in alarm, thus eliminating much of the guesswork when responding to front-panel indications. If a detector is removed for any reason while the panel is in its normal state, a zone trouble condition will result. This ensures the integrity of the alarm system at all times. EC30U-3 detectors are manufactured to strict international ISO 9001 standards. All electronics employ surface mount technology ISMT) for smaller size and greater immunity to RF noise. A corrosion-resistent conformal coating is used to seal components against dust and humidity. Application Thanks to its high-performance photoelectric sensor, the EC30U -3 responds quickly and reliably to all fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings. Particles as small as 0.5 microns will be detected by the sensing element, triggering an alarm at the first sign of smoke. GE Security recommends that all detectors be installed according to the latest recognized edition of national and local fire alarm codes. 0 imagination at work www.gesecurity.com 8985 TOWN CENTER PARKWAY, BRADENTON, FL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES:OWEN SOUND. ON 519-376-2430: FAX 519-376-7258 INTERNATIONAL SALES: (001)905-270-1711; FAX (001) 905-270.9553 Literature Sheet *85001-0552 Issue 2 Not to be used for installation purposes. Page I of 2 4.65 (118 mm) Mounting Wiring The detector mounting bases will accept #18 AWG (0.75mm2). #16 (1.0mm2), #14 AWG (1.5mm2) and #12 AWG (2.5mm2) wire sizes. CSBLJ-1: Standard detector base Provides plug-in tamper- resistant mounting. Includes screwtermina(s for connection of installation wires. F,070 0078d 70081 NOT 10 BE IJSE() FOR IF3tIAILATIOI4 P LI PI)tC compatibility Panel model Zone model Maximum Detectors Zone ID UI. ULC UL I ULC QuickStart ZA8-2, ZB16-4 40 30 100 EST1-2Z3, -2Z3R, -2Z6, .2ZR 46213-2101, -2102, .2104, -2105 40 00 EST3 IDC8/4 48 30 00 I 0.0 LSS4/12(R), LSS4/36(R), LSS4/52(R) BZEXP, 4CLA, Motherboard 48 0.0 LSS4(R) 4ZEXP 48 0.0 IRC-3 130108, 240113, 240119 48 3289B 130082, 48 3289A 240124 (RZB12-6 only) 48 5389 FCC 130108, 240113, 240119 48 3289B 130082 48 3289A FireShield CPU 24 24 100 I 100 Specifications Operating Voltage Range 14 - 30 Vdc Normal Operating Current 64,A Alarm Current 100 mA (max.) limited by control panel Sensitivity Range 1.38- 3.08% obs/ft Test Feature Sensitivity reading using Test/Picker Tool Operating Environment Altitude Not Applicable Temperature 32° F to 100° F (0° C to 38° C) Humidity 20 - 95% RH (non condensing) Air Velocity 0 - 5,000 ft/mm (manufacturer rated) 0- 300 ft1min (UL listed) Storage Environment 32° F to 1200 F (0° C to 49° C) Temperature Maximum Spacing 30 ft (9.1 m) centers Construction White molded high-impact fire-retardant plastic UL Compatibility ID A Compatible Bases See Ordering Information Ordering Information Model Description Ship Wt. lb (kg) EC30U-3 Low-profile Plug-in Photoelectric Detector 0.25 (0.11) CSBU-1 Standard detector base 0.11 (0.05) CS1341.1-1 4° Standard detector base CRB4U-1 4° Detector base with relay CSBU-3 Detector base with resistor EC-LED Remote Alarm LED 0.4(0.18) C-TRIM Trim skirt for standard base 0.4 (0.18) C-PST I Detector picker/sensitivity tester 1.4 (0.64) EC Series with Standard Base Standard bases mount to the following electrical boxes: North American 31h inch octagon boxes North American 4 inch octagon boxes North American 1-gang electrical boxes European 1-gang boxes with 60.3 mm fixing centers European BESA boxes wWW.gesecurity.com It is our intention to keep the product information current and accurate. we can not cover specific applications or anticipate all requirements. All specifications ore subject to change without notice. For more information or questions relative to this Specification Sheet, contact GE Security. © 2003 GE Security Printed in USA. Page 2o1 2 Literature Sheet #85001-.0552 issue 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:135 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models EC301.1-3 and *Ec30Du..3 photoelectric type, 2-wire smoke detectors. *The EC30DU-3 is a potted version of Model EC30U-3 the potting material is used to prevent air leaks and is used in applications for duct detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12-30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units. *Model EC30DU-3 may be used as a duct smoke detector. NOTE: Formerly 7272-1591:135 and 7272-1388:245 *Rev. 09-29-2005 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. *73001501:136 Page 1 of 1 CATEGORY: *Misc Device/Control Unit Accessories LISTEE: Edwards Signaling, 90 Fieldstone Court, Cheshire, CT 06410 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Model CSBU-1 and *CsBu..3 detector bases. Base is for use with Models SC1 OU-3, SC30U- 3, smoke detector heads and Models SC20FTU-3 and SC20RRU-3 heat detector heads. Model CSBU-3 is similar to the CSBU-1 except CSBU-3 employs resistor inside the base. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a detector base for use with separately listed compatible fire alarm control units. NOTE: *Formerly 7271-1501:136 XLF: *73001591:214 *Rev. 09-29-2005 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager EOWANDS SYSTEMS TECHNOLOGY Part of GE Security h1kTI 1111] JI1L%IIKI1*'A[*i ---EST3T] Fire Alarm Stations 270 Series Features Pull lever Simple positive operation Breakglass I Attractive, streamline design I Less than 5 lb pull force complies with ADA I Solid, die-cast metal construction Description The GE Security 270 Series Non-Coded Fire Alarm Stations are sturdy, attractive, and designed for economical installation. The station is available in the following operational and functional designs: — The 270 Series provides a single action, break gloss initiating station. It is available with normally open (NO.), normally closed (NC.) or combination N.O./N.C. contacts. The basic 270 Series have screw terminals for field connection. The 270A Series Manual Stations have 6 inch (150mm) wire leads. — The 270P Series is a break gloss, normally open pre-signal station. The pull of the lever sounds an alarm an all pre-signal indicating devices. Inserting a key and turning it will initiate a general evacua- tion alarm. Screw terminals are provided for field connection. All non-coded statins are designed for either flush or surface mounting. For flush mounting a 4 inch standard North American square box with single gang plaster cover should be used. For surface mounting the 270 Series or 270P Series, use P-027193 Cast Box, P-039250 Steel Box. or Cat. No. 1291 Housing for weatherproof enclosure. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. 0 MEA Ordering Information All models are fire alarm red with Aluminum Strips. They are marked "Pull in Case of Fire" on the pull handle. Cat. No. Marking (top of device) Switch Contacts Field Connections Pre-Signal Single Pole Double Pole Open Circuit Screw Terminals Wire Leads 270.DPO Fire Alarm x x x 270-DPO-L Local Alarm x x x 270-SPO Fire Alarm x x x 270A-DPO Fire Alarm x x x 270A-SPO Fire Alarm x x x 270P-DPO Fire Alarm x x x x 270P.SPO Fire Alarm x x x x 0 imagination at work www.gesecurity.com 8985 TOWN CENTER PARKWAY, BRADENTON, FL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES: OWEN SOUND, ON 519-376-2430: FAX 519-376-7258 INTERNATIONAL SALES: (001)905-270-1711; FAX (001)905-270-9553 Literature Sheet #85001-0303 Issue 6 Not to be used for installation purposes. Page 1 of 2 - DOOR RELEASE FOR TEST & RESET AND GLASS REPLACEMENT GEN ALARM KEY SWITCH S.P.S.T. (INCLUDED WITH PRE-SIGNAL STATIONS) ONLY WALL SURFACE - (INCLUDED WITH PRE-SIGNAL STATIONS) ONLY I DETAILS FLUSH MTG. UNIT FITS 4" SO BOX & PLASTER COVER WITH SINGLE GANG OPENING HAVING OVERALL MIN. DEPTH OF 114' - i- 3-9/16" (25mrnTfl90mmi 1 4-9/16" (1 16mm) 0 CAST SURFACE BOX P-027193 FRONT SIDE P27165 GLASS ROD FLUSH INSTALLATION USING P-024900 STEEL BOX 3-513r (80mm) NOT TO BE USED FOR INSTALLATION PURPOSES Mounting -v--i- 1-1/2 (25mm) (38mm) 3-hr L—_ 3-1/2 - (89mm) F— (80mm) (2rnm) i] '14.1/2 I I (114mm) H •iJ FRONT SIDE STEEL SURFACE BOX P-039250 www.gesecurit.com It is our intention to keep the product information current and accurate. We can not cover specific applications or anticipate oil requirements. All specifications are subject to change without notice. For more information or questions relative to this Specification Sheet, contact GE Security. 612004 GE Security Printed in USA Page 2012 Uterature Sheet #85001-0303 Issue 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1657:111 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models 270,270P, 270-SPO, 270A-SPO, 270-DPO, 270A-DPO, 270-DOC, 276B, 27713, 278B, 279B, 279TC, 279P, 279T, 279L, 276A-REL, 278A-REL, 5966B, 596613R, 5966BV, 5966BRV, 629613-270, 6296B-K279, 6296B-1279, 8557-13301, 8557-133111, 8558-13301, 8558-13311 and 8558-13312 manual pull stations. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as non-coded fire alarm pull stations for use with separately listed compatible fire alarm control units. NOTE: 1. Models provided with two-wire lead and normally closed switch contacts are not approved for fire alarm signaling use. 2. Formerly 7150-1591:111, 7150-1388:121 and 7150-0073:117 08-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. tractors & Engineers NOTIFICATION APPLIANCES 650 Opper Street 9 Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 • C1O-#85046 EDWARDS SYSIThS TSCHNOLOV Part of GE Security ROTIFICATIONL1J! IT T T Field Configurable Horns and Strobes Gi Series Features Unique low-profile design - The most compact UL-1971/ULC-5526 listed strobe available - Ultra-slim -protrudes less than one inch from the wall - Attractive appearance - No visible mounting screws I Four field-configurable options in one device - Select 15, 30, 75,01 110 cd strobe output - Select high (default) or low dB horn output - Select temporal (default) or steady horn output - Select public mode flash rate (default) or private mode temporal flash I Easy to install - Fits standard 1-gang electrical boxes - no trim plate needed - Optional trim plate accommodates oversized openings - Pre-assembled with captive hardware - #12 AWG terminals - ideal for long runs or existing wiring I Unparalleled performance - Industry's mosteven light distribution - Meets tough synchronizing standards for strobes - Single microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control over a single pair of wires - Highly regulated in-rush current - Multiple frequency tone improveswall penetration - Industry's firsttemporal strobe output Description The Genesis line of signals are among the smallest, most compact audible-visible emergency signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, GE Security Genesis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions lightto produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLighttechnology. FuilLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ectable 15,30,75, 110 cd strobeL_.,. One or more patents pending. ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required 'T pattern, significantly exceeding UL-1971 and ULC-S526 light distribution requirements. Although all Genesis strobes are self-synchronizing, when installed with an optional synchronization module, strobe flashes from devices on the some circuit synchronize to within 10 milliseconds of each other indefinitely. This exceeds the two-hour minimum specified in the UL standards. Only one synchronization module is required per circuit. Genesis strobes and horn-strobes offer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the device. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unauthorized tampering. Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent wall penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with ajumper cut that reduces horn output by about 5dB. Genesis signals feature textured housings in architecturally neutral white or traditional fire red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occupants regardless of what language they speak. Models with "FIRE" markings are also available. 0 imagination at work www.gesecurity.com 8985 TOWN CENTER PARKWAY, BRADENTON, FL 34202 PHONE: 888-378-2329 • FAX: 866-503-3996 CANADA SALES: OWEN SOUND, ON 519-376-2430: FAX 519-376-7258 INTERNATIONAL SALES: 10011 905-?70-1711: FAX (aOl) 905-270-9553 Literature Sheet #85001-0573 Issue 3 Not to be used for installation purposes. Page 1 of 6 OT TO BE '.JSEO FOR IT'lST.ALATlON I' 1.1 EE. Application 3enesis strobes are UL 1971-listed for use indoors as wall-mounted public-mode notification appliances forthe hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87dBA in Canada). where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act (see application notes- USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes The following guidelines are based on ANSI/NFPA 72 National Fire Alarm Code (1999). When applied and installed in accordance with that code, GE Security strobes meet or exceed the illumination produced by the ADA-specified 75 candela (cd) strobe at 50 feet* Non-Sleeping Rooms EST wall mounted strobes Up to 20'x 20(6.1 m 6.1 m) One 15 cd strobe Up to 30'x 30(9.1 m 9.1 m) One 30 cd or two 15 cd strobes Up to 40'x 40(12.2 m 12.2 m) One 75 cd or two 30 cd strobes Up to 50'x 50(15.2 m 15.2 m) One 110 cd or two 75 cd strobes Corridors Any length. Maximum width: 20' (6.1m). 15 cd strobes spaced at 100' (30.5 m) max. Strobes must be placed within 15'(4.5m) of each end of the corridor. * ADA suggests using 75 ad strobes throughout an area, with spacing that never exceeds 50 ft from the strobe to any point in the protected space. 3n-Sleeping Rooms and Corridors: GE Security strobes rated at less :hon 110 cd per UL 1971 are intended for use in non-sleeping areas only. Install with the bottom of the device at least 80 inches (2.0 ml and no more than 96 inches (2.4 ml above the finished floor. No point in any space (including corridors) required to have strobes should be more than 50 feet (15.2 ml from the signal (in the horizontal plane). For detailed spacing requirements, consult The Handbook of Visible Notification Appliances for Fire Alarm Applications published by GE Security Press, or contact your local GE Security representative. Sleeping rooms: GE Security 110 cd strobes are intended for use in sleeping rooms and should be installed along with a smoke detector. It must be wall mounted at least 80(2.03 ml above floor level, but no closer than 24(610mm) to the ceiling. The distance from the strobe to the pillow must not exceed 1614.8 ml. Sleeping Rooms EST wall mounted strobe Any size 110 cd within 16 feet of pillow Horns The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 ml above the floor. The average ambient sound level is. A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Application Notes - USA Audible signals in the public mode should never have a sound level less than 75 dBA at 1013 ml per NFPA 72. Signals cannot exceed 120 dBA per ADA and NFPA 72 at the minimum hearing distance to audible appliance. Strobe and combination horn/strobe devices should be installed with the bottom of the device at least 80 inches (2.0 ml and no more than 96 inches (2.4 ml above the finished floor. Horns should be installed with their tops not less than 6 inches (152 mm) below the ceiling and not less than 90 inches (2.3 ml above the finished floor. Strobes must be used to supplement audible signals wherever the average ambient sound level exceeds 105 dBA. Combination audible/ visual signals must be installed in accordance with NFPA guidelines established for strobes. ADA requires visible signals in the following areas: rest rooms, meeting rooms, and other common use areas. sleeping rooms intended for use by persons with hearing impairment (in accordance with Title 1 o ADA). work areas used by a person with a hearing impairment (per Title 1 of ADA). Application Notes - Canada (Based in part on 1995 Canada National Building Code) The fire alarm signal sound pressure level shall not exceed 110 dBA in any normally occupied area. The sound pressure level from on audible signal in a floor area used for occupancies other than residential occupancies shall not be less than 10 dBA above ambient levels, and never less than 65 dBA. In sleeping rooms the sound pressure level from an audible signal shall not be less than 75 dBA when any interven- ing doors between the device and the sleeping room are closed. Audible signal devices shall be installed not less than 1.8 m to the center of the device above the floor (per CAN/ULC 5524). The fire alarm audible signal shall be supplemented by fire alarm strobes in any floor area where the ambient noise level exceeds 87 dBA, or where the occupants of the floor area use ear protective devices, are located within an audiometric booth, or ore located within sound insulating enclosures. This also applies to assembly occupancies in which music and other sounds associated with performances could exceed 100 dBA Strobes shall be installed in a building so that the flash from one device is visible throughout the floor area or portion thereof in which they are installed. For maximum safety. GE Security recommends that strobes be installed as per the guidelines shown here under Strobe Spacing. www.gesecurity.com Page 2 of 6 Uterature Sheet #85001-0573 Issue 3 Genesis Horn/Strobe with optional trim plate NOT TO BE USED FOR INSTALLATION PURPOSE. Installation Genesis horns and strobes mount to any standard one-gang surface or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gong, four- inch square, or octagonal boxes, and European 100 mm square. All Genesis signals come pre-assembled with captive mounting screws for easy installation. Two tabs at the top of the signal unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Field Configuration Temporal horn and horn-strobe models are factory set to sound ma three-pulse temporal pattern. Units may be config- ured for use with coded systems by cutting ajumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit, A Genesis Signal Master is required when horn-strobe models are configured for coded systems. Non- temporal, horn-only models sound a steady tone. Genesis strobes and horn-strobes are shipped from the factory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting ajumperon the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting ajumper on the circuit board. This reduces the output by about 5d8. Wiring Field wiring terminals accommodate #18 to #12 AWG 10.75 mm' to 2.5 mm21 wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. Polarity alarm c next device end of line device Note: Strobes must have continuous voltage. www.gesecurity.com Issue 3 Uterature Sheet #85001-0573 Page 3 of 6 Average Sound Output (dBA) (High dB setting, anechoic. 24V. measured at lOft) Or --- Light output-(effective cd) Percent of UL rating versus angle P1 Ced Ut W. NOT 10 BE USED FOR INSTALLATION PURPOSES. specifications Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Lens Optical grade polycarbonate (clear) Mounting Flush mount: 2½ inch (64 mm) deep one-gang box (indoor wall mount only) Surface mount: EST model 27193 surface mount box, wiremold box, or equivalent surface-mount box With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor only: 32-120'F (0-49'C) ambient temperature. 93% relative humidity Agency UL 1971, UL 1638, UL 464, ULC S525, ULC S526, CSFM, CE, FCC, (MEA, FM pending). listings/approvals (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions (HxWxD) Signal: 4-1/2 x 2-3/4 x 13/16' 013mm x 68 mm x 21 mm) Trimplate: 5 (127 mm); Height— 5-7/8 (149 mm); Depth — 1/2"(13 mm) G1-HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional G1M Genesis Signal Master) G1-VM series strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR G1-P series steady-tone horns: coded or non-coded, filtered 20-31 Vdc or unfiltered 20-27 Vfwr Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output G1-VM strobes and G1-HDVM series temporal-tone horn-strobes: one flash per second synchronized with Strobe flash rate optional 131M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Compatible synchronization G1M, G1M-RM, SIGA-CC1S, SlGA-MCC1S modules G1-HD temporal-tone horns and G1-HDVM series temporal-tone horn-strobes: temporal rate synchronized Horn pulse rate with optional G1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1M Genesis Signal Master) G1-P steady-tone horns: continuous, steady tone only 'emporai audible pattern ½ sec ON, ½ sec OFF. ½ sec ON, ½ sec OFF, ½ sec ON, 11/2 sec OFF, then repeat cycle Temporal Horns, Horn-strobes (G1-HD. G1-HDVM series) — Hiah dB Settina UL464 Average Peak Temporal I Steady Temporal/Steady Temporal/Steady 16 Vdc 81.4 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 96.9 99.5 Temporal Horns. Horn-strobes 1131-HD. G1-HDVM jeries) — Low dB Settino UL464 Average Peak Temporal I Steady Temporal/Steady Temporal/Steady 16 Vdc 76.0 80.1 86.3 89.2 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 95.3 Steady Tone Horns (131-P series) 11L464 Average Peak 16 Vdc 77 90 91 24 Vdc 77 90 91 33 Vdc 77 90 91 Notes All values shown are dBA measured at 10 feet 13.01ml. UL464 values measured in reverberation room. Average and Peak values ore measured in onechoic chamber. www.gesecurity.com Page 4 of 6 literature Sheet #85001-0573 issue 3 Measured by EST RMS I Mean I 24 Vdc 10 10 24 dc 11 11 31 Vdc 12 12 20Vfwr 9 8 24Vfwr 10 9 - NOT 10 BE USED FOR lNS11 LATION P1!R'0SE Current Draw Strobes, Horn-Strobes Multi-cd Wall Strobes (G1-VM) III NnIt ReIinn IIIL171 Pffective May 20flfl 15 c 30 c 75 c 110 c RMS RMS RMS RMS 16 Vdc 103 141 255 311 16Vfwr 125 179 346 392 Tvoical Current (Measured by EST) 15 c 30 c 75 c 110 c RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 85 79 127 124 245 243 285 283 20 Vdc: 71 66 98 96 188 186 240 238 24 Vdc 59 55 82 80 152 150 191 190 33 Vdc 46 44 64 63 112 111 137 136 16Vfwr 119 64 169 97 1 332 1 203 376 240 20Vfwr 103 51 143 76 253 150 331 198 24Vfwr 94 44 129 65 218 121 262 152 33Vfwr 87 1 37 112 52 179 89 205 106 Multi-cd Wall Temporal Horn-strobes (G1-HDVM) - High dB Setting ULNameolate Ratina (UL1971. Effective May 20041 15 c [ 30 c J 75cd 110 c RMS RMS RMS RMS 129 [ 167 j 281 337 176 J 230 J 397 j 443 Tvoical Current (Measured by EST) 15 c 30 c 75 c 110 c RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 102 89 135 129 246 242 309 305 20 Vdc 88 77 109 104 193 190 248 243 24 Vdc 81 71 94 90 161 158 203 200 33 Vdc 1 74 64 72 74 124 121 154 151 16Vfwr 144 77 1 182 1 106 352 212 393 249 20Vfwr 141 68 162 87 274 158 362 210 24Vfwr 136 65 152 76 235 133 282 165 33Vfwr 125 54 1 144 1 65 201 101 232 123 Multi-cd Wall Temporal Horn-strobes (G1-HDVM) - Low dB Setting UL Nameolata Ratino 1tiL1971 Effective May, 20041 15 c 30 c 75 c 110 c RMS RMS RMS RMS 122 160 274 330 162 216 383 429 Tvoical Current (Measured by EST) 15 c 30 c 75 c 110 Cd RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 96 84 130 124 243 240 302 297 20 Vdc 79 70 104 99 189 186 241 237 24 Vdc 68 61 88 84 156 154 197 193 33 Vdc 56 52 71 68 118 116 146 143 16Vfwr 128 69 180 104 1 344 1 204 389 244 20Vfwr 118 60 157 84 266 156 343 200 24Vfwr 113 1 54 144 74 230 1 128 279 161 33Vfwr 112 1 48 137 64 197 1 99 226 117 Horns Wall Temporal Horns (G1-HD) UL Namenlate Retina (UL464 Effective May 20041 High dB Low dB RMS RMS 16 Vdc 26 19 24 Vdc 36 27 33 Vdc 41 33 16Vfwr 51 37 24Vfwr 69 52 33 Vfwr 76 70 Tvical Current (Measured by EST) High dB Low dB RMS Mean RMS Mean 16 Vdc 22 17 17 14 20 Vdc 24 19 19 16 24 Vdc 27 21 22 18 33 Vdc 32 25 26 22 16Vfwr 34 1 15 30 14 20Vfwr 40 19 34 16 24Vfwr 45 21 38 18 33Vfwr 52 24 47 22 Wall Horns (GI-P) UL Nameplate Rating I RMS I Mean I 16 Vdc 9 7 24 Vdc 11 9 33 Vdc 13 1 11 16Vfwr 9 5 24Viwr 10 7 33Vfwr 1 11 9 Notes and Comments Current values are shown in MA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. GE Security recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. S. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. 6. Our industry has used 'mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. 16 Vdc 16 Vfwr 16 Vdc 16 Vfwr www.gesecurity.com Issue 3 Literature Sheet #85001-0573 Page 5 of 6 NT TO CF USED FOR INST Al. LATIO14 PI'RPC)SE,. ordering Information Catalog Number Description Ship Wt. lbs (kg) White Finish Red Finish G1-HDVM G1R-HDVM Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, selectable high/low dB output) 0.25 G1-VM G1R-VM Genesis Strobe (selectable 15, 30, 75, or 110 cd output) G1-HD G1R-HD Genesis Temporal Horn (selectable high/low dB output) G1-P G1R-P Genesis Steady Horn (not compatible with Genesis Signal Master) G1F-HDVM G1RF-HDVM Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, selectable high/low dB output) —with FIRE marking G1F-VM G1RF-VM Genesis Strobe (selectable 15. 30, 75, or 110 cd output) — with "FIRE" marking G1F-HD G1RF-HD Genesis Temporal Horn (selectable high/low dB output) —with "FIRE" marking G1F-P G1RF-P Genesis Steady Horn with "FIRE" marking (not compatible with Genesis Signal Master) Mounting Accessories G1T GiRT Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) G1T-FIRE GiRT-FIRE Genesis Trim Plate (for two-gang or 4" square boxes) with "FIRE" markings 0.15 (0.7) 27193-16 27193-11 One-gang surface mount box 1(0.4) Synchronization Modules G1M Genesis Signal Master — Snap-on Mount G1M-RM Genesis - Remote Mount -gang) _Signal _Master _(1 0.2(0.1) SIGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 (0.08) Genesis Horn-Strobes may be ordered in red or white. with orwithout'FIRE' FIRE - marking. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. These visible signal appliances' flash intensity may not be adequate to alert or awaken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. GE Security recommends that strobes in sleeping rooms be 110 cd minimum. Genesis and FuilLight Strobe Technology are trademarks of GE Security, Inc. www.gesecurity.com it is our intention to keep the product information current and accurate. We can not cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information or questions relative to this Specification Sheet, contact GE Security. © 2005 GE Security Printed in U.S.A. Page 6 of 6 literature Sheet #85001-0573 issue 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.. 7125-1657:202 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models "EST G1-HV15, -HV30, -HV60, -HV-75, GI-HOV15, -HOV30, -HOV60, -H0V75, -HOV1 10, GIF-HOV1S, -HOV30, -HOV60, -H0V75, -HOVIIO, GIRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, G1F-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCF-HDVMH, 131- HDV1575, G1R-HDV1575, G1F-HDV1575, and GIRF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33 VdcNfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF- HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCF-HDVMH, G 1-HDV1575, GI R-HDV1575, G1 F-HDV1575, G1 RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, ll0cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models GI-HDV1575, Gi R-H0V1575, G1 F-HDV1575, GI RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135- 1657:230). For indoor use and wall mount only. Models GC-HDVM and GCF-HDVM for ceiling mount only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Formerly 7125-1591:202 08-17-05 '..L. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. actors & Engineers BATTERIES 650 Opper Street 9 Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 • C10485046 UB12120 (12V12Ah) NOTE Nominal Voltage 12V Nominal Capacity (20HR) 12Ah Length 151 +/-lmm(5.94 inches) Dimensions Width 99 +/-lrnxn(3.90 inches) Height 96 +/-2mm(3.78 inches) Total Height 102 +/-2mm(4.02 inches) Weight Approx. 4.0 kg (8.821bs) Standard Terminal Fl - Faston Tab No. 187 Dimensions (mm) 11 .............. 96 102 Standard Terminal mm Fl (Fast Tab No. 187) I- _ Optional Terminal mm Fl (Foot Tab No. 250) I - •' - .1 20 hour rate (0.35A) 12 Ah Max. Discharge Current (5 sec.) 100A Capacity 10 hour rate (0.63A) 10.8 Ah 5 hour rate (1.12A) 9.6 Ah Initial Charging Current less 1 hour rate (4.2A) 7.2 Ah Cycle than 3.6A Voltage 14.40V - Constant .00 - at 20°C(68°F) Temp. Coefficient-30mV/°C Capacity affected 40°C(104°F) 105% by Temperature 20°C(68°F) o°C(32°F) 100% 85% Charge Voltage Standby Initial Charging Current less than 3.6A Voltage 13.50\T 13.80V at Internal Resistance Fully charged battery (20°C, 20°C (68°F) 68°F) 20m111iohms Temp. Coefficient-20mV/°C DdiareChamcterisfis (2Ot,6 ° ° clii -- 9.0 _J2 7FI-FTF i= Si 1 2 3 5 10 2030 60 2 3 5 10 20 30 I]. h................. Ddiare..Tüne 15 1111111 lb)3 - - - - - . 20 -- mm) ~F, I01Fj' 10 'l (32 I1iiiII1iii_iI 5 2 ii DmdiargeCurrnt