5922 FARNSWORTH CT; ; FA150068; Permit
6/6/24, 2:12 PM FA150068 Permit Data City of Carlsbad Fire Alarm Permit 5922 FARNSWORTH Job Address: CT Permit Type: FALARM Parcel No: 2120701100 Lot #: 0 Reference No.: PC #: Permit No: FAI 50068 Status: APPROVED Applied 10/8/2015 Approved: 10/14/2015 Issued: 10/14/2015 Inspector: Project Title: CARLSBAD TECHNOLOGY TI Applicant: TYCO INTEGRATED SECURITY 3830 CALLE FORTUNADA SAN DIEGO, CA 760458-0161 Owner: CARLSBAD TECHNOLOGY INC 5923 BALFOUR CT CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 290 0 290 0 about:blank 1/1 tqca 'Integrated Security Fire Alarm Record of Completion lSW III II I0 1101 101 IH H II H 8806UE00 Date: OZ4/1.2 //'Cstomer#:IJ/6 Job #: 6 Primary System #: O /&7Y'Secondary System #: Customer Name: eA! /r L..-.Z' I,v p i, Address(City/State/ZIP)' '5 /_.4 /. /7j 717 C'7'. /C C / & i- Representative of Protected Property (Name/Phone): _.90.,K4 Authority Having Jurisdiction: /'?C. 1.. Telephone #: Location of As-Built Drawings: Location of Operation and MaintenanceManuals: (.., &x 7 4, , (1 Location of Inspection & Testing Reports: f Location of Control Panel: 4' ( e A .' <' C_. / Primary Telephone #: / 4 7 /T 7e elephone #: Does Tyco have a contract for testing and inspection in accordance with NFPA standard(s)? I'Y 0 No' If no. who?: Inspection Start Date: Inspection Frequency: 0 Annually 0 Semiannually 0 Quarterly 0 Bimonthly 0 Monthly [:]Weekly - System Software Operating system (executive)-software revision level(s): (b) Site-specific software revision date: Revision completed by: (Name) (Company) .. (Date) Type(s) of System or Service (NFPA 72. Chapter 8— Tyco Central Monitoring Center - Means of transmitting signals from the premises to the centraistation: (Check all that apply). Digital ,Alarm Communicator 0 McCulloh 0 Multiplex '0 One-way Radio . 0 Two-way Radio 0 Other: Means of transmission of alarms to the public fire service communications center: 7#__ct jø_I::::df System locations: o NFPA 72, Chapter 6- Local If alarm is transmitted to location(s) off premises, list where received: A,.,- 0 NFPA 72, Chapter 8- Remote Station Telephone numbers of the organization receiving alarms: _-cf - 0 NFPA 72, Chapter 8- Proprietary Telephone numbers of the organization receiving alarm: 0 NFPA 72. Chapter 9-Auxiliary Check type of connection: "Local Energy 0 Shunt 0 Parallel Telephone Telephone numbers of the organization receiving alarm: If alarms are retransmitted to a public fire service communications center or other, indicate name and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: C ./O .4 Record of System Installation (Complete this section after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been i stalled in accordance with the NFPA standards as shown below, was inspected by . \OJ q,*i / / on Ii,_ .includes the devices shown in sections 4 & 5, and has been in service since This system has been installed in accordance with the standards as shown below: E(NFPA 72, Chapters 1 0-2 rI'3 D'4 D'I Di 0"7 D" D D.' 0 11 (Check all that apply) D'iFPA 70, National Electrical Code, Article 760 l"Manufacturer's Instructions or Other Source: CA .4d7 /c..__a 10 Signed: . ) organization: .. Reprinted with permission from NFPA 72 ® 2002, National Fire Alarm Code®, Copyright © 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. @2012 Tyco Integrated Security. All rights reserved. (06/12)' (p. 1 of. 3) Control Panel Date: Integrated cuH 'I .'l • I Fire Alarm Record of Completion, cont. 8806UE00 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features and functions of this system were tested bS),.i, /l / /éed,,r6.a4.- date 1e y ) / And found to be operating properly in accordance with the requirements of: D-NFPA72,Chapters .-1 2 9-3 Q4 EJ5 9-6 9-7 I3-8 [3"9 [T10 D 11 (Check all that apply.) [.NFPA 70, National Electrical Code, Article 760 Eliianufacturer's Instructions AHJ or Other Source: /1-. )(signed: - 74-Date: i.. ,corganization: 4. Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity - Style Class 5. Alarm-Initiating Devices and Circuits Quantity and class of signaling line circuits connected to system (see..NFPA 72, Table 6.6.1): Quantity 2. Style Class /7 Manual Manual stations Non-coded . - Coded Transmitters Addressable Combination manual fire alarm and guard's tour coded stations .. .. Automatic Coverage: (Check all that apply) 0 Complete 0 Partial 0 Selective . 0 Non-required. Enter quantities and check it the devices are addressable. Smoke detectors Ion Photo Duct detectors Ion --- Photo (C) Heat detectors - FT RR (ci) Sprinkler waterfiow indicators: Non-coded ' 0 Addressable 0 Addressable FTIRR RC Coded Transmitters Addressable Addressable The alarm verification feature is 0 Disabled 0 Enabled , changed from Other (list): 6. Supervisory Signal-Initiating Devices and Circuits Guards Tour: 0 (a) Coded stations ' 0 (b) Non-coded stations seconds to seconds. - (c) Compulsory guard's tour system comprised of transmitter stations and intermediate stations. Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. (Check if provided.) Sprinkler System: (a) Valve supervisory switches (b) Building temperature points. (c) Site water temperature points (d) Site water supply level points Other supervisory function(s) (specify): Electric fire oumo: (e) Fire pump power (f) Fire pump running (g) Phase reversal Electric-driven fire oumo: (h) Selector in auto position (i) Engine or control panel trouble U) Fire pump running. Electric-driven aenerator: (k) Selector in auto position (I) Control panel trouble (m) Transfer switches (n) Engine running -V.. Reprinted with permission from NFPA 72®2002, National Fire Alarm Code®, Copyright © 2002. National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. @2012 Tyco Integrated Security. All rights reserved. (06/12) (p. 2 of 3) Control Panel tEico Integrated Security Fire Alarm Record of Completion, cont. - 7. Annunciator(s) II II IH 111111111 HIll OH lIH 110 II 8806UE00 Quantity: Type: Location(s): 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6— Emergency Voice/Alarm Service Quantity of voice alarm/alarm channels:: Single: Multiple: Quantity of speakers: Quantity of speakers zones: Quantity of telephones or telephone jacks attached to the system: Types and quantities of notification appliances installed: - Bells With Visible: - (d) Chimes With Visible: Speakers With Visible: (e) Other: With Visible: (C) Horns X j With (f) Visible appliances without audible: (1X 2...') 9. System Power Suppi Fire Alarm Control Panel Nominal voltage: Current rating ( Over-current protection: Type: Current rating Location: Secondary (standby): Storage battery - Amp-hour rating: Calculated capacity to drive system, in. hours: (24) (60) Engine-drwen ge?ierator dedicated to fire alarm system: Location of fuel storage: .-. Emergency system used as backup to primary power supply-.- Emergency system described in NFPA 70, Article 700 10. Comments Frequency of routine tests and inspections,. if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: Customer Comments: Customer Name: Signature: Print Name Date Tyco Representative Name ',,.,.. /2 '/?6 r Signature: 7"L, _!--- Print Name Date Upon completion of the system(s) satisfactory test(s) witnessed (if required by the Authority Having Jurisdiction): AHJ Representatively--, I ) 1) \ 'ature - / / Print Name Date - • N ( ititlè: . > ...,. - Telephone #: Reprinted with permission from NFPA 7252002, National Fire Alarm CodeS, Copyright 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. 02012 Tyco Integrated Security. All rights reserved. (06/12) (p. 3 of 3) Control Panel tqco FA1,50068 3870 Murphy Canyon Road, Suite 140 San Diego, CA 92123 (858) 633-9521 DF-60601 Al • A1-60 MS-9200UDLS(E) Rev Flre•LlTeALarms Intelligent Addressable FACP with Built-In Communicator by Honeywell General Addressable Fire Alarm Control Panel The Fure•Lite MS 9200UDLS Rev .3 with Version 5 0 firmware Is a combination fACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board This compact intelligent addressable control panel has an extensive lust of powerful features While the MS 9200UDLS Rev 3 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode it can also operate in LiteSpeedTM mode—Fire.Lite s latest : .•• polling technologfor a quicker device response time.. LiteSpeeds patented technology polls 10 devices at a time This improvement allows a fully loaded panel with up t6-198 devices to report an incident and activate the notification cur cults in under 10 seconds. With Utespeed'pollirig; deviceé can . 0 ,• be wired on standard twisted unshielded wire up to a distance of 10,000 feet The MS 9200UDLS Rev 3s quick remove chassis protects the electronics during construction The backbox can be installed allowing field wiring to be pulled When construction is com- pleted, :the electronics can. be quickly installed with just two . ... bol. . . New features for Rev 3'wlth Version 5.0. firmware include removable terminal blocks improved transient protection additional secondary ANN-BUS, and increased power for the . .. . resettable and remote Sync outputs. Available accessories include ANN-BUS devices as well as Features ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. Listed to UL standard 864, 9th edition. The integral DACT transmits system status (alarms, superviso- On-board DAd. ries, troubles, AC loss, etc.) to a Central Station via the public Remote site or local USB port upload/download, using PS- switched telephone network. It also allows remote and local Tools. programming of the control panel using the PS-Tools Upload! Four (4) Style V (Class B) NAC circuits, which can be con- Download utiIity. In addition, the control panel. may be pro- veiled to four (4) Style Z (Class A) circuits with optional grammed or interrogated off-site via the public switched te!e- ZNAC-92 converter module. (Up to 6.0 amps total NAC phone network. Any personal computer with Windows® XP'or power When using optional XRM-24B.) greater, a. compatible modem, and PS-Tools—the Fire•Lite Selectable strobe synchronization for . System Sensor, Upload/Download software kit—may serve as a Service Termi- Wheelock, and Gentex devices. nal. This allows download of the entire program or upload of Remote Acknowledge, Silence, Reset and Drill via address- the entire program, history file, walktest data, current status able monitor modules or LCD-80F,-ANN-80 or Legacy ACS and system voltages. The panel can also be programmed Annunciators through the FACP's keypad or via a standard PS-2 computer Keyboard, which can be plugged directly into the printed circuit ANN-BUS for connection to following optional modules (cannot board. This permits easy typing of address labels and other be used if ACS annunciators are used): programming information. - ANN-80(-W) Remote LCD Annunciator Version 5.0 firmware supports the following: Primary and Sec- - ANN-I/O LED Driver ondary ANN-bus devices, AD355 (LiteSpeed), USB port, NAC - ANN-S/PG Printer Module circuit diagnostics, a new report has been added to the walk- - ANN-RLY Relay Module test that lists untested devices, new device types added: audio - ANN-LED Annunciator Module telephone type code for ACC 25150ZST, Photo Supervisory and auto-resettable Drill (non-latching). - ANN-RLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT-2 - ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the ACS/TERM: Internet saving the monthly cost of two dedicated business - ACS Annunciators: Up to 32 Legacy ACM Series annun- telephone lines. Although not required, the secondary tele- ciators (ACM-1 6AT or ACM-32 series). Cannot be used if phone line may be retained providing backup communication ANN-BUS devices are used. 0 over the public switched telephone line., .. - Terminal-mode Annunciators: Up to 32 Legacy LCD-80F NOTE: Unless othe,wise specified, the term MS-9200UDLS is . remote annunciators. used in this document to refer to both the MS-9200UDLS and the : •, . 0 MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). DF-60601:A1 • 12/07/2010— Page 1 016 EIA 232 printer/PC interface (variable baud rate) on main circuit board for use with optional UL listed printer PRN 6F Integral 80-character LCD display with backlighting. Real-time clock/calendar with àutomatió daylight savings control. : Detector sensitivity test:capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu mulation is excessive Automatic device type-code verification. One person audible or silent walk test with walk test log and printoUt. . .:. Point trouble identification Watert low. (nonsilenceable) selection z per monitor point System alarm verification selection per detector point PAS (Positive Alarm Sequence) and presignal delay, per point (NFPA 72 compliant) NOTE: Only detectors may patticipate in PAS...• SLC LOOP SLC can be configured for NFPA Style 4j 6 or 7 operation SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10000 it. (3,000'm.).. See installation manual for wire tables.. •. NOTIFICATION APPLIANCE C1RCL ITS NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to fOur Class A NACs-with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE. Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface .. . . LED INDICATORS AC Power (green) . Supervisory, (yellow) Alarm Silenced (yellow) System Trouble (yellow) . . .. . .. Maintenance/Presignal (yellow) .• Disabled (yellow) . . ,.. ... . .. Battery Fault (yellow) . . Ground Fault (yellow) KEYPAD CONTROLS AcknowledgO/Stép •. . • . .:. Alarm Silence Drill. .. . . . • .... System Reset (lamp test) 16 key alpha numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information MS-92001.11DLS 198 point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. :120 VAC operation MS 9200UDLSE Same as MS-9200UDLS except with 240 VAC operation 4XTMF Reverse .. Polarity Transmitter MOdule; Provides supervised output for local energy municipal box transmitter, alarm, and trouble; ZNAC-92: Optional converter module which converts four (4) Style V (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PK-CD Programming software for Windows®-basedPC com- puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting.. BAT SerieS: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 3(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming and updating panel firmware. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/21.11D, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to. primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldát VisorALARM Central Station Receiver. Can use DHCP or static IR (See data sheet DF-60407 or DF-52424 for more information.) . . . Fire Alarm (red) Page 2 of 6— DF-60601:A1 • 12107/2010 Z. IPBRKT Mounting kit for IPDACT2/2UD in common enclo DNRW Innovair Flex low flow non relay duct detector hous sure.. . .: •. . ing with NEMA4 rating. Watertight. .(Order SD355R sepa. : ..•. IPSPLT V adaptor option allows connection of both panel IBt&y) dialer outputs to one IPDACT-2/2UD cable input. MMF-300: Addressable Monitor Module for one zone of nor- COMPATIBLE ANNUNCIATORS mally-open dry-contact initiating devices. MountS in standard 4.0".(10.16 cm) box Includes plastic cover plate and end of ANN-80(-W) LCD Annunciator is a remote LCD annunciator line resistor..Module may be configured for either a Style B that mimics the information displayed on the FACP LCD dis (Class B) or Style D (Class A) IDC play. Recommended wire type is un-shielded (Basic model is MDF-300 Dual Monitor Module Same as MMF 300 except it red order W version for white see DF52417) provides two Style B (Class B) only. lDCs ANN LED Annunciator Module provides three LEDs for each MMF-301 Miniature version of MMF 300 Excludes LED and zone Alarm Trouble and Supervisory Ships with red enclo Style D option Connects with wire pigtails May mount in sure (see DF 60241) device backbox ANN RLED Provides alarm (red) indicators for up to 30 Input MMF-302 Similar to MMF 300 but may monitor up to 20 con zones or addressable points (See DF 60241) ventional two wire detectors Requires resettable 24 VDC ANN-RLY Relay Module which can be mounted inside the power. Consult factory for compatible smoke detectors cabinet provides 10 programmable Form C relays (See DF 52431) ROME Relay Option Module Enclosure Provides one ANN ALY Relay Module already installed The 1,ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi module (See Installation Sheet PN 53530) ANN S/PG Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF 52429) ANN I/O LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430) ACM-SRF: Relay module provides 8 Form-C 5.0 amp relays.: . . . ACS-LED Zone SeFles: LED-type fire annunciators capable of . . . . providing up to 99 software zones of annunciation. Available in . . . .. . •• increments of 16 or 32 points to meet a variety of applications. . . LDM Graphic Series: Lamp Driver Module series for use with . . custom graphic annunciators. . LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS Rev 3, see the following data sheets (doc- ument numbers) ACM-8RF (DF-51555), ACS/ACMSeries (DF- 52378), LDM Series (DF-51384), LCD-80F (DF-52185). .LITESPEED COMPATIBLE ADDRESSABLE DEVICES . •. . All feature a polling LED and rotary switches for addressing. . . CP355: Addressable low-profile ionization smoke detector. . SD355: Addressable low-profile photoelectric smoke detector. S03551: Addressable low-profile photoelectric smoke detec- .. . . . tor with thermal sensor. SD355R: Addressable remote test capable detector for use with D355PL or DNR(W) duct smoke detector housings. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355H1: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile, intelligent, Adapr multi-sensor detec- tor (B35OLP base included). BEAM355: Intelligent beam smoke detector. • . . BEAM355S: Intelligent beam smoke detectOr with integral . . . . . . sensitivity test. . . . .. . .. S . ,. D355PL; lnnovair Flex low-flow non-relay duct-detector hous- ing. SD355R included. •. . • •• . . . DF-60601:A1 • 12/07/2010 - Page 3 of 6 CMF 300 Addressable Control Module for one Style NZ (Class B/A) zone of supervised polarized Notification Appli ances. Mounts directly to à40" (10.16 cm.) electrical box Notification Appliance Circuit option requires external 24 VDC to power notification appliances. . . . CRF-300: Addressable. relay module containing two isolated . sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cnt)b0x, surface mount using the SMB500 BG-12LX Addressable manual pull station with interface mod ule mounted inside 1300 Fault Isolator Module This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 opera tion). .. . . ••. S. .. . S •.••, .5 . . .. SMB500 Used to mount all modules except the MMF 301 and M301. •• . . .5 . ...... -. . •• . ..• 111111111F-300-ft Ten input monitor module Mount one or two modules in a BB 2F cabinet (optional) Mount up to six mod ules on a CHS-6 chassis in a1313-61F. .. . . MMF 302-6 Six zone interface module for compatible conven tional two-wire detectors. Mount one or two modules in a BB- . • 2F cabinet (optional). Mount up to six modules on a CHS6 chassis in a BB I 76F. CMF-300-6 Six-circuit supervised control module Mount one or two modules in a BB 2F cabinet (optional) Mount up to six modules on a CHS-6 chassis in a 1313-61F. CRF-300-6: Six Form-C relay control module. Mount one--or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. .. . .. NOTE:. 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS Rev 3, see the following data sheets (document numbers): AD355 (DF-52324), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-60379), CMF/CRF Sénes (DF-52130), CP355 (DF-52383), D355PL (DF- 52398), H355 Senes (DF-52385), 1300 (DF-52389), MMF-300 SerieslMDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), SD355/5D355T (DF-52384). 2) Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)/ SD350(T) and older modules such as the M300, M301, M302, C304, and BG-IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard LiteSpeed protocoL Please consult factor/ for further information on previous 300 Series devices.. . Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. Page 4 of 6— DF-60601:A1 .12/07/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 7165-0075:0208 Page 1 of 1 CATEGORY 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE FIRE-LITE ALARMS INC One Fire-Lite Place No Word, CT 06410-1653 Contact Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email Brian. Reynolds2(HoneyweII corn DESIGN Models MS 9200UD and MS-9200UDLS addressable control units Local auxiliary remote station central station and proprietary (protected premise) Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessones When required accessories shall be CSFM listed RATING 120 VAC 60 Hz 206 A Primary 24 VDC Secondary INSTALLATION In accordance with listee's printed installation instructions applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING Listee s name model number electncal rating and UL label APPROVAL Listed as an addressable lire alarm control panel for use with separately listed compatible • initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit cangenerate a distinctive three-pulse Temporal Pattern Fire Alarm • Evacuation Signal (for total evacuation) in accordance with NFPA 72 2002 Edition *MS9200UDLS panel also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM # 6911-0075:0226). • This control unit meets the requirements of UL4864,. 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 11-12-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct: operational requirements or installation cntena Refer to listee's data sheet installation instructions and/or other Date Issued:' July 01, 2015 • • ListiAg Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordihator Fire Engineering Division Descriptiofl The Wheelock* ExcederTM Series of notification appliances feature a sleek modern design thatwill please building ownerswith reduced - Save up to 48% in Current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test - Up to ,,,9 models now in 1 appliance points, 12/24 VBC operation, universal mounting base and multiple mounting options for both new and retrofit construction. A . r. . - save up to I '.j' cost or instaiiation The Wheelock® Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the.notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99' dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® Exceder Series of wall and ceiling notificatiOn appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated 'screw to prevent the screw from falling during installation. AWKA Sleek Modern Aesthetics AVA Finger Slide Switches 'Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB O-~, 8 Candela Settings Wall - 15/1575130175195111011351185 Ceiling - 15/30/60/75/95111511501177 S Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw 1 Compatibility and Requirements ' -Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol -Compatible with UL Regulated Voltage 'using filtered VDCor unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltag? range J * Compared to competitive models Patented Compared to previous models ' NOTE All CAUTIONS and WARNINGS are Identified by the symbolA All warnings are printed in bold capital letters. ., •.• Ak WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCTVISIT5WWWCOOPERNOTIFICATION COM OR CONTACT1COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCtiONS FAILURE TOCOMPLYWITHANYOFThESE INSTRUCTIONS CAUTIONSOR WARNINGS COULD RESULT IN IMPROPERAPPLICATiON INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. GehraINótes: . .., General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'... - . All candela ratings represent minimum effective strobe intensity based on UL Standard 1971 . ., . .. Series Exc.eder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 327 to 120F (O"C 649C) and 1• maximum humidity of 93% (± 2%) UL 4r>4 (85% Ut. 1971) Series Exceder horns are 'under UL Standard 464 for audible signal appliances (Indoor use only). . ...... . . . Draw . . . . . ... ....................... .• S1'A'1iJ1t1III Ij )TV Fewer Power J i [ IStrobe Ratings per UL Standard 1971 UJ Max Current' i 1 24 VDC /24 FWR ' 12 VDC ' Model Regulated Voltage 15 15/75 30 60 110 115 135 150 177 185 15 15/75 ST 80-330 0057 0070 0085 0135 0163 0182 0205 0.253 0110 0140 STC 80 330 0061 0085 0103 0135 0163 ~O.82 _____ 0205 0253 0110 Horn Strobe Ratings per UL 1971-& Anechoic at 24VDC ' ••••UL . . : : :- Max Current* at . W99 1 24VDC : Ii1 . 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 RanoeVDC HS . . 8.0-33.0 0.082 I 0.095 I 0.102 0.148 0.176 0.197 0.242 .0.282 I 0.125 0.159 I HSC 8.0-33.0 I 0.082 0.102 I 0.141 0.148 I 0.176 10.197 I 0.242 0.282 -- 0.125 NITA I 24VDC . -12 VDC Model Regulated Voltage 15 15/75 30 60 75 1 95 110 115 135 .150 .177 185 15 15/75 RangeVDC HS 8.0-33.0 . 0.073 0.083 0.087 0.139 I 0.163 0.186 0.230 0.272 0.122 0.153 HSC . 8.0-33.0 0.073 O.O7 0.128 0.139.I 0.163 0.186 0.230 0.272 0.122 - UL Max Current- at Anechoic 90 dBA 24VDC . . . 12 VDC .1 Model. . Regulated Voltage 5/75 30 f 60 75 95 110 [us 135 150 177 J .185 15 15/75 HS 8.0-33.0 j0.0651 .075 0.084 0.136 0.157 0.184 - 0.226 0.267 0.120 0.148 8.0-33.0 0.084 0.120 1 0.136 0.157 = 0.184 - 0.226 0.267 0.120 Horn Ratings per UL Anechoic - - - Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 80-175 0.047 0.026 0.017 E * UL max current rating is the maximum RMS current within thdiisted voltage range (16 33 VDCfor 24 VDC units) For strobes the UL max current Isusually at the minimum listed voltage (16 VDC for 24 VDC units) For audibles the max current IsiJsuallyat the maximum listed voltage (33 VDC for 24 VDC units) For unfiltered ratings see installation instructions Specification & Ordering Information Sync wt . . . . . Model . Strobe : DSM or 12124 VDC* Mounting Candela .Wheelock Power Options Suppiiei. . .. . . . S.. HSR• 1-i 1511575130175195111011351185 . .x : .x F. . UMW* HSW 1511575/30175195111011351185 X X UMB i5I3OI6OI75I95I115I15O/177 ... ..• :. . x ....• . . . UMB. HSWC 151301601751951115/1501177 X X UMB** • SS ST.R. ....• •.. . 15/1575/30175/95/110/135/185 . .. .. .. . . . .... ... .;. UMB: STW , 1511575130/75195111011351185 X X UMB** • STRC .. .. . 15130160175195111511501177 •. .•. . X . S. . . UMB . ... STWC . . • 15130160/75195111511501177 . X X. . . . . UMB • : . .. . . X .X UMB** . .. .•... HNW . . . . .. X X:UMB** Rc: . . . X . . X . VUMB. S X UMB X X rchitecand Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL StSndatd 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HNAudibles shall be.UL Listed under Standard '464 (Fire, Protective Signaling).. All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible: with standard reverse polarity supervision of circuit winng by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC Indoor wall models shall incorporate voltage test points for easy voltage inspection The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall: incorporate a Xenon flashtube enclosed, in a rugged Lexan® lens. The Series shall be of low cuirent design. Where Multi-Candela appliances are specified the strobe intensity shall have 8 field selectable settings at 16i 15175 30,'75 95 110 135 185 candela for wall mount and 15 30 60 75 95,115, 150 177 candela for ceiling mount The selector switch for selecting the candela shall be tamper resistant The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance) Appliances with candela settings shall show the candela cti vi seleon in a sible location at all times when installed The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs The Series HS Audible Strobe ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang double-gang 4-inch square 3.5-inch octal 4-inch octal or 1 00m European type back boxes Two wire appliance winng shall be capable of directly connecting to the mounting base Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed Product shall come with Contact Cover to protect contact spnngs Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP) The mounting base shall be the same base among all horn strobe rn ho strobe wall and ceiling models All notification appliances shall be backwards compatible The Senes HS and ST wall models shall have a low profile measuring 524 H x4 58 Wx 2.1. 9 D Series HN wall shall measure 524 H x 4 58 W x 1 6 D The Senes HSC and STC shall been round and have .a low profile with a diameter of 668 x 263 D Senes HNC ceiling shall have a diameter of 668 x 1.60- D 'When synchronization isreq'uirèd1.the appliance'shall be compatible with Wheelôck°'s DSM Sync Modules, Wheelock Power Supplies." or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to,a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range.. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM ''a WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY ' Excedér - Spec Sheet 6111 Wheelock' (CJ SAFEPATH WAV) Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 . •. . .: . . .. Pagel of 1 CATEGORY 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE Cooper Wheelock Inc 7246 16th St E Ste 105 Sarasota FL 34243 Contact Tom Conover (941) 487-2336 Email thomas conover@cooperindustries corn DESIGN Exceder Series: Models ST strobe HS horn strobe and HN horn Model ST is a synchronous and non synchronous strobe light Model HS a visual/audible appliance and Model HN is an audible signal appliance All units followed by R:( red) or W (white) Additionally a C may be added for ceiling models and/or a -NR may be added for non-resettable models For non -NR models and optional S for silver fascia may be added* Refer to listee S data sheet for additional detailed product description and operational considerations RATING Electrical 12 VDC/24VDC/FWR Candela (wall) 15,.15f751,30, 75 95 110 135 & 185 Candela (celling)* 15 30 6 '75,95,115,150,&177 INSTALLATION: In accordanc with listee's printed installation instructions, applicable côdès and ordinances and ma manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listèe's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not , : an endorsement or recommendation of the item listed. This listing should: not be used to verify correct operational requirements or installation criteria. Refer to listee s data sheet installation instructions and/or other Date. Issued: July 01, 2016 . I ListingExpires June 30,2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division . ., . SD355 wIth B35OLP base SD355T with B35OLP base Applications Use photoelectric detectors in life-safety applicationS to pro- vide a broad range of fire-sensing capability, especially where -smbldering fires are' anticipated. Ionization detectors are-often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white LEXAN®. 5D355(1) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation SD355(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: - 4.0 (10.16 cm) square box with plaster ring. 4.0'(10.16 cm) octagonal box. 3.5".(8.89-cm) octagonal box. - Single-gang box. • • •. • NOTE: Because of the inherent supervision provided by the SLC loop, and-of-line resistors' are not required. Wiring '7-taps" or - branchèi are permitted for Style 4 (Class B) wiring. - SD355R mounts in a D355PL or DNR(W) duct detector housing. SD355(A)9 SD355T(A), SD355R(A) FlreLrreALarms Addressable Photoelectric Smoke Detectors by Honeywell General The SD355(A) and $D3551(A) addressable, low profile plug of the art photoelectric in photoelectric detectors use a state sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lites Address- able Fire Alarm Control Panels (FACPs) The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (570C) Since these detectors are addressable they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local visible sensor indication Remote LED annun ciator capability is available as an optional accessory (P/N RA1 0OZA)). The SD355R is a remote test capable detector•• for use with 0355PL or .DNR(W) duct smoke detector hous- Features SLC loop Two-wire loop connection. : . Unit uses base for wiring. . . . . ..Addressing:. . . . . .. Addressable by device. Direct. Decade entry of 'address: 01 - 99 with MS-9200 series, and 01.— 159 with MS-9600 series. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type Identification. • Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. . Operation: . Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec,) without triggering a false alarm. Factory preset at 1.50/6 nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. . . . 94-VO plastic flammability rating. Low standby current. Options: . Remote LED outpUt connection (P/N RA100Z).. df-52384:b • 3/12/10 - Page 1 of 2 Operation Product Line Information Each SD355/TIR uses one of 99 possible addresses on the NOTE °A'suff,x indicates U1.6.0sted model MS 9200 series and up to 318 (159 on each loop) on the MS SD355 Adressable photoelectric detector, 8350LP base 9600 series Signaling Line Circuit (SLC). It responds to regular . . . included. . polls from the system and reports its type and status.SD355A Sames as 5D355 with ULC Listing (B350LPA base The SD3551T/R addressable• photoelectric sensor's unique included). . . . ... . unipolar chamber responds quickly and uniformly to a broad . .. . . . . range of smoke conditions and can withstand wind gusts up to SD355T Same as SD355 but with thermal element 8350LP 4,000 feet per minute (20 m/sec) without sending an alarm base included level signak Because of its unipolar, chamber, the SD355/T/R SD355TA Same as 5D3551 with ULC Listing (9350LPA base is approximately two times more responsive than most photo included) electric sensors This makes it a more stable detector.'SD355R Remote test capable addressable photoelectric Detector Sensitivity Test detector for use with a D355PL or DNR(W) duct detector hous ing Each detector can have its sensitivity tested (required per 8350LP(A) Plug in detector base Di%mensions 6 1 (155 NFPA 72 Chapter 14 on Inspection Testing and Maintenance) cm) Mounting 40 (10 16 cm) square box with or without when installed/connected to a MS 9200 series or MS-9600.plaster ring 4.0".(10.116 cm) octagonal box 3;5' (889 cm) series addressable fire alarm control panel The results of the octagonal box or single gang box..All mounting boxes have a sensitivity test can be printed off the MS 9200 series or MS minimum depth of 1.50 (381 cm) 9600 series for record keeping.-B224RB(A) Plug in System Sensor relay detector base Specification Diameter. 62 (15.75 cm).' Mounting 40 (10 16cm) square box with or without plaster ring-4.0':(10.16Cm) octagonal box, Voltage range 15-32 VDC (peak) or 3.5..(889 cm) octagonal box All mounting boxes have a 1 . .minimum Standby current 300 pA 0 24 VDC depth of 1.5 (3.81 .Cm).. . •.. . . . . . LED current 65 mA @ 24 VDC (latched ON) 1 B224B1(A) Plug-in: System Sensor Isolator detector base Maximum 25 devices between isolator bases (see DF 52389) Air velocity 4,000 ft 1mm (20 m/sec) maximum Diameter. 62 (1575 cm) Mounting 40 (11.0.116 cm) square Diameter: 1 1155 cm' installed in B35OLP base . box with or without plaster ring, 4.0' (10.16 cm) octagonal box, .!i . . .. . or.3.5 (8.89 cm) octagonal box; All mounting boxes have a Height: 2.1 (5.33 cm) installed in B350LP base. . minimum depth of 1.5'(1.8.1 cm).- Weight: 3.6 di., (102 g). . .. . . . . B200SR: Sounder base capable of producing témporal-3 or Operating temperature range: for SD355(A): 0°C to 49°C steady sound output . . 1')O 1.. 1')A°. £,.. Ofl.TIA . flf' 4, 'QOf' opom +,s innoci % Is Ik U d %JtJ .I I •W I UU I J. SD355R1A): installed in a DNR(W) -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F —120°F). Relative humidity: 100/6 - 93%, non-condensing. Listings Listings and approvals below apply to the 5D355(A) and 5D355T(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult.factory for latest listing status. UL Listed, file S1059. ULC Listed, file S1059. . CSFM approved: file 7272-0075:194. MEA approved: file 243-02-E. FM approved. ACCESSORIES:• HAl OOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B35OLP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. M02-04-00:Test magnet . M02-09-OO: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes In three 5-foot (1.524 m) sections. T55-127-010:Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. FlashScan® registered trademark of Honeywell intematlonai Inc. Bay- blend® is a registered trademark of Bayer Corporation. 02010 by Honeywell international inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. . ISO 9001 We try to keep our product information up-to-date and accurate. • , . We cannot cover all specific applications or anticipate all requirements. MIIfNi IIWI1iI!1 All specifications are subject to change without notice. QUALITY SYSTEMS . . . . . .. . . .. For more information, contact Fire.Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.fireiite.com Page 2 of 2 —df-52384:b 9 3/12/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. . '. .7272-0075:0194 .......... ....": . •' ' . 'Page .1 of 1. . . . CATEGORY 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE FIRE-LITE ALARMS INC One Fire-Lite Place, Northford CT 06410-1653 Contact Bnan Reynolds (203) 484-7161 Fax (203) 484-7309 Email Bnan ReynoIds2@Honeywell com DESIGN Models SD350 5D350T 5D355 5D355R* 5D355T and AD355 photoelectric type smoke detectors Model SD350T and SD355T has a 135°F supplement integral heat sensor which only assists in 'a fire situation The purpose of this thermal circuitry is to increase the sensitivity of the detector This thermal circuitry is QI approved for use as a heat detector. Refer to listee s pnnted data sheet for additional detailed product description and operational considerations RATING 24VDC INSTALLATION In accordance with listee s printed installation instructions applicable codes .& ordinances and a manner acceptable to the authority having junsdiction MARKING:. . Listeé's name, model number, electrical rating aAd'UL label. . APPROVAL: .Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models SD355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires Which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. Rev. 01-11-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of' any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.' Refer to listee's data sheet, installation instructions and/or other Date Issued:. July 01, 201.5 . ' : Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I Intelligent Bases B200SR, B501(A), B3501.P(A), B501 BH-2, B501 BHT-2, B501 BHA, 0501 BHTA, 0224RB(A),. 022401(A) MoUnting Kits,-and AccessorieS General Intelligent mounting bases and kits provide a variety of ways to install Fire'Lite detectors in any application Intelligent detec tors can be mounted in either flanged or flangeless bases depending on Junction box selection (see Junction Box Selec- tion Guide) Across this product line detectors plug in easily to the base with SEMS screws; andmodels employ, various 12 to 24 AWG wire ranges Relay, isolator, and sounder bases can be used to meet local code: requirements; Relay bases provide one Form-C' contact relay for control of auxiliary functions such as door clo- sure and elevator recall. lsoiátobáses'aliow loops to continue to operate under fault conditions and automatically restore when the faUlt iS removed Sounder bases are available in temporal and non-temporal pattern. versions depending on Whether the signal is to be used for evacuation purposes The RMK400 recessed mounting kit provides the most sea-. thetically pleasing installation Surface mounting boxes are available when flush mounting isn't possible Specifications .. . Diameter: —8501:4;l'(104mrn). —82248!, B224RB, B350LP:6.1' (155 mm).' - B501BH-2, B501BHT-2:6.0' (152 mm). - B200SR: 6.875° (17.46 cm). Wire gauge: - 8224B1, B224RB. 14 to 24 AWG. - B35OLP, B501, B50IBH-2, B501BHT-2, B200SR: 12 to. 24 AWG. Temperature range: —fl224Bl, B224RB, B501BH-2, B501BHT-2, B200SR: 32°F to 120°F(0°Cto49°G). - B501 and B35OLP,-4°F to' 150°F (0°C to 66°C). Humidity range: 100/6 to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 1200F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2%. at 32°C ± 2°C (89.60F .t 1.1°F) per ULC. However, the useful life of the sys- tem's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings FOR B200SR: External supply voltage: 16 to 33 VDC (VFWR) Standby current: 500 hA maximum. - Alarm current: 35 mA maximum. SLC operating voltage: 15 to 32 VDC. SLC standby current: 300 hF. - Sound output: measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone). Greater than 85 dBA minimum. FOR B224RB, B224B1: Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB only): short delay 55 to 90 msec; long delay 6 to 9 seconds. ' Reset time (B224RB only) 20 msec maximum. Relay characteristics (B224RB only): two-coil latching 'relay; one Form-C contact; ratings (UL/CSA): 0.9 A 0 125 VAC, 0.9 A 0 110 VDC, and 3.0 A 0 30 VDC. FOR B501BH-2, 8501BHT-2: External supply voltage: 17 to 32 VDC. Standby current: 1.0 mA maximum. Alarm current: 15 mA maximum. Maximum ripple voltage: 10% of supply voltage. Startup capacitance: 200 pF. Sounder delay time: For B501BH-2 and B501BHT-2, 0.75 to 5.7 seconds. Sound output: greater than 90 dBA measured in anechoic room at 10 feet (3.048 m), 24 volts. 85 dBA minimum in UL reverberant room. Recessed. Mountiflg Kit The RMK400 can be used with drywall or sUspended ceilings. The aesthetically pleasing design can be used with standard junction boxes - suitable for use with 4.0°'(1O.16 cm) octago-' DF-60059:B • 01/22/2010 - Pagel of 2 nal 50 mm and 60 mm junction boxes connected to flexible MOUNTING KITS AND ACCESSORIES conduit Note that junction boxes are not included in the kit As RMK400 Recessed mounting kit an application example with the B501 base the RMK400 pro- vides a simple installation solution in applications that demand SMK400E. Surface mounting it, a g ... a lower-profile smoke detetor. ., . SMB600: Surface mounting kit, flanged. . .• Product Line Information Fl 10 Retrofit flange for B501 B B524 RA100Z Remote LED annunciator. INTELLIGENT BASES RA100ZA Remote LED annunciator, ULC Listed B501 Flangeless mounting-base.M02-04-00 Detector test magnet B501 A: Flangeless mounting base ULC Listed M02-09-00 Test magnet with telescoping handle 65016P Bulk pack of 9501 (10) XR2B Detector removal tool (T557127 000 included) 0350LP Flanged mounting base.XP-4 Extension pole for XR213 (5 to 15 A11.524 to 4.572 m) B35OLPA Flanged mounting base ULC Listed.T55 127-000 Detector removal head . B200SR:Intelligent sunde. base. capable of producing sound Rik dttnr kit nnkn of in (fnr use .with •: . .• output with :3 or continuous, tone: Replacs the B501BH ..photo and .. TT series bases in retrofit applications WCK-200B: White detector kit, package of 10 (for-user-With E11501112111-11-2.: Plug-in System Sensor standard sounder detec- photo and ion detectors).'. S . •. tor base steady tone Includes B501 base B01BHT-2: Plug in System Sensor temporal tone sounder Agency Listings and Approvals The listings and approvals below apply to intelligent bases as B501BHA Plug-in System Sensor standard sounderdetector noted In some cases certain modules or applications may not •• base, steady: tone, with ULC Listing. includes B501 f?. . . be listed by certain approval agencies, or: listing may be. in • pro-..oval .•:. •• B501 BHTA Plug-in System Sensor temporal tone sounder cess Consult factory for latest listing status base with ULC listing • UL Listed 5911 B224RB: Relay base. . . . . • ULC Listed: S91 1 . . . B224RBA: Relay base, ULC Listed. . •• • FM Approved • .. . .. . B224B1: Isolator base. : . .. • MEA: 22-95-E, 205794-E Vol. 2; 257-06-E. . B224B1A: Isolator base, ULC Listed. • CSFM: 7300-0075:192, 7300-1653:109; 7300-1653:126, 7300-1653:191 Junction Box Selection Guide Base Models Single Gang Double Gang 3.5" Oct. 4.0 Oct. 4.0" Sq. 40"S with 3. mud ring 50 mm 60 mm 70 mm 75 mm B200SR Yes Yes No Yes Yes No No No No No B501 No No Yes No No . Yes Yes Yes Yes No B350LP .. Yes . No Yes Yes Yes Yes No No Np .No B224RB . No No Yes Yes Yes No No Yes Yes Yes B224B1 No No Yes . Yes Yes No No No Yes Yes B501BH-2 No No No No Yes . No No No No No B501 BHT-2 No No No No Yes No . No No No . No NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Fire.Lite® Alarms and System Sensor€) are registered trademarks of Honeywell international inc. 02010 by Honeywell international Inc. All rights reserved. Unauthorized use of this document is Strictly prohibited. This document is not intended to be used for installation purposes. .. . ISO- 9001 . . We try to keep our product information up-to-date and accurate. • . . We cannot cover all specific applications or anticipate all requirements. BIiIlNi IMNlUfiIUN. . All specifications are subject to change without notice. . QUAlITY SYSTEMS . . . . . . . . . . Madein the U.S.A. For more information, contact FireLite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. • www.firelite.com Page 2 of 2— DF-60059:121 • 01/22/2010 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 000 LISTING No 7300-0075 0192 Page 1 of I CATEGORY 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE FIRE-LITE ALARMS INC One Fire Lite Place Northford CT 06410-1653 Cdhtactf Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email Brian.Reyholds2@HoneyWell.com DESIGN Model B350LP detector base Refer to listee s data sheet for additional detailed product descnption and operational considerations RATING:. INSTALLATION In accordance with listee s printed installation instructions applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING Listee's name model designation electrical rating and UL label APPROVAL Listed as a detector base for use with listee s separately listed Models CP350 SD350 5D350T H350 and H350R detectors NOTE: I *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the .test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing, should not be used to verify correct V operational requirements or installation criteria. Refer to listee s data sheet installation instructions and/or other :Daté Issued: July 01, 2016 Listing Expires June 30 2016 Authonzed By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division