HomeMy WebLinkAbout555 TAMARACK AVE; ; AS110060; Permit6/20/24, 8:51 AM AS110060 Permit Data City of Carlsbad Sprinkler Permit Job Address: 555 TAMARACK AV Permit Type: SPRINK Parcel No: 2060422500 Lot #: 0 Reference No.: Permit No: ASII0060 Status: ISSUED Applied 4/20/2011 Approved: 4/20/2011 Issued: 4/20/2011 PC #: Inspector: Project Title: RESIDENTIAL FIRE SPRINKLERS TWO FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: SYMONS FIRE PROTECTION SUITE R 1050 PIONEER WAY EL CAJON, CA 619-588-6364 Owner: MILLS JACK B TR P0 BOX 991 CARLSBAD CA LII Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 H J.~Ipsulfing RStLcocc 1: 3 eyE 350 West 91h Avenue, Suite 206 Escondido, California 92025-5053 Telephone (760) 745-6181 Fax(760) 745-0537 April 18, 2011 Mr. James Weigand City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Single Family Residence, 555 Tamarack Avenue, Carlsbad, California Dear Mr Weigand: We have reviewed the submittal as prepared by Symons Fire. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required. We had no comments. Sincerely, PAjLEY CONSULTING Office Manager ' End (1) Working Drawings - 2 sets (2) Hydraulic Calculations - 2 sets Note: A copy of this letter has been transmitted via fax to Symons Fire on April 18, 2011 - fiie:\C:\Docnments and Settings\Ken\Rev21 I I49.001.wpd Check a License - Contractor's State License Board FILE COP) Page 1 of Contractor's License Detail - License # 682025 DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. CSLB complaint disclosure is restricted by law (B&P 7124.6) If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. Per B&P 7071.17 , only construction related civil judgments reported to the CSLB are disclosed. Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number 682025 Extract Date: 4/20/2011 SYMONS FIRE PROTECTION INC 1050 PIONEER WAY SUITE R Business Information EL CAJON, CA 92020 Business Phone Number:(19) 588-6364 Corporation Issue Date 12/14/1993 Reissue Date 12/17/2002 Expire Date 1213112012 License Status This license is current and active. All information below should be reviewed. Additional Status: CLASS DESCRIPTION Classifications. C16 FIRE PROTECTION CONTRACTOR CONTRACTOR'S BOND This license filed Contractor's Bond number 167153 in the amount of $12,500 with the bonding company AMERICAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 01/01/2007 Contractor's Bonding History Bonding: BOND OF QUALIFYING INDIVIDUAL 1. The Responsible Managing Officer (RMO) EMERY TOO EUGENE certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 08/25/2008 BQI's Bonding History This license has workers compensation insurance with the Workers' Compensation: OAK RIVER INSURANCE COMPANY Policy Number:2200053917101 https://www2.cslb.ca.gov/OnhineServices/CheckLicensellfLicenseDetail.aspx?LicNum6,.. 04/20/2011 Check a License - Contractors State License Board Page 2 of 2 Effective Date: 10/0112010 Expire Date: 10/01/2011 Workers' Compensation History DATE DESCRIPTION Miscellaneous Information: 12/17/2002 LICENSE REISSUED TO ANOTHER ENTITY Personnel listed on this license (current or disassociated) are listed on other licenses. Personnel List 11 Other Licenses Conditions of Use I Privacy Policy Copyright © 2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicensell/LicenseDetail.aspx?LicNum6... 04/20/2011 The plans have len r.'viewed for appuivnt compliance %% III, the current applicable codes and standards in 101cc in the urtsdkiittn. The owner or contractor iita utultie this revuess In suplxwt of an application br a building perutal sc tilt the express understanding that this reviess in no was relieves the owner or contractor ou their priulessiotual engineer or architect for sole iespoutsihulity for full compliance with said codes and standards. including the building code or fill any responsihilty for deficiencies. errors. omissuoiis Or negligence in these plans whether or not noted in his review Date: Reviewer: 0414/ RECOMMEND APPROVAL kw RECOMMENI) APPROVAL. AS NOTED C, 84 /4 /211 11:45 619588685 SYMONS FIRE PROT PAGE 1/5 .HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. LICENSE : 682025 1 kig DESIGNER : CANDI CAUDILLO DATE : 04-04-2011 ' Q*~- IG FILE : 11-034--A JOB NAME : SF'H - TAMARACK LOCATION : 555. TAMARACK AVENUE, CARLSBAD, CA DESIGN DATA. DESIGN CRITERION: NFPA 13—D MIN SPR FLOW : 18 Gpm AREA PER SPRINKLER : 324 Sq Ft TOTAL CALCULATED AREA : 324 Sq Ft TOTAL SPRINKLERS CALCULATED : 1 Heads FLOW DATA. TOTAL SPRINKLER FLOW : 18.0 Gpm DOMESTIC DEMAND : 5.0 Gpm TOTAL WATER REQUIRED : 23.0 Gpm BASE OF RISER NODE: I-I FLOW: 23.0 Gpm —PRESSURE: 27..1..Pffl CITY OF CLSt1 FIRE DEPARTMENT APPROVED Sublect to field 'Inspectionand required tests notations hereon cofld%tlOfls in correspondence and conjol, mance with applicable regulations. The stamping all not be held to permit Of thes an violation of any law orap e Date By AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DE T. PHONE : 760-602-4666 04/04/2011 11:45 6195886805 SVrY1ONS FIRE PROT PAGE 02/05 !1YDP.ONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 1 ENGINEERS : SYi4ONS FIRE PROTECTION. (619) 598-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 04-04-2011 File: C:\RESDEN43\11-034-A.RES JOE : SFH - TAMARACK SOURCE I STATIC : 85.0 Psi RESIDUAL : 84.0 Psi. FLOW : 23 Gpm DESIGN I SPRINKLER MANUF : RELIABLE MODEL : RFC 43 CONC/ FLAT I SPRINKLER Q : .0 Gprn VALVE : .0 Psi I SPRINKLER P : .0 Psi METER : 3.0 Psi. NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm A 16.0 ----------------------------------------------------------- 4.3 17.5 18.0 B 16.0 18.4 C 16.0 19.1 D 16.0 20.2 E 16.0 20.2 16.0 21.3 G 16.0 22.5 H 9.0 27.1 5.0 DOME I 5.0 30.7 J 3.0 34.2 K .0 SOURCE 42.0 23.0 SPRINKLERS FLOWING : 1 AREA PER SPRINKLER : 324 Sq Ft TOTAL DESIGN AREA : 324 Sq Ft REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .055 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 18.0 Gprn TOTAL DOMESTIC FLOW : 5 Gprn TOTAL WATER REQUIRED 23.0 Gpm TOTAL SPRINKLER PRESS 39.0 Psi WATER METER LOSS : 3.0 Psi VALVE FIXED LOSS .0 Psi Copyright (2002) SUPPLY P:RESS AVAILABLE : 84.0 Psi by DEMAND PRESS REQUIRED 42.0 Psi Hydronics Engineering PRESSURE CUSHION : 42.0 Psi 34119 Fremont Bi, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 9.5 F/S (510) 4879160 uqf'ui.ii 11:4b bi3b8bb3Ub SYMONS FIRE PROT PAGE 83/05 HYDRCNICS RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 04-04-2011 File: C\RESDEN43\11-034-A.RES JOB : SFE - TAMARACK PIPE EEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. GPM FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) qm 18.0 --------------------------------------------------------------------------------- K= 4.3 L= 5.0 Pt 17.5 Ft 17.5 Q= 18.0 F= 1B1L F= 12.0 C= 150 P€ .0 Pv -.2 V€1= 6.1 D= 1.101 TL= 17.0 .0558 Pf .9 Pn 17.2 B Pt 18.4 q= .0 --------------------------------------------------------------------------- K= .0 L= 44.0 Pt 18.4 Pt 18.4 2 Q= 7.6 F= 3R35 F= 18.0 C= 150 Fe .0 Pv .0 Ve1= 2.6 0= 1.101 TL= 62.0 .0114 Pf .7 Pn 18.4 C Pt 19.1 B 9= .0 --------------------------------------------------------------------------- K' .0 L= 64.0 Pt 18.4 Pt 18.4 3 Q= 10.4 Fm 4R351L F= 26.0 C= 150 Pc .0 Pv -.1 Ve1= 3.5 D= 1.101 TL= 90.0 .0201 Pf 1.8 Pp 18.3 Pt 20.2 C q= .0 K .0 11= 65.0 Pt 19.1 Pt 19.1 4 Q= 7.6 F- 4R4B1L F= 31.0 C= 150 Fe .0 Pv .0 Ve1= 2.6 D= 1.101 TL= 9.0 .0114 Pf 1.1 Pn 19.1 E) Pt 20.2 I) .0 --------------------------------------------------------------------------- K= .0 L= 65.0 Pt 20.2 Pt 20.2 5 Q= 7.6 F 9R3B F= 24.0 C= 150 Fe .0 Pv .0 Ve1= 2.6 D= 1.101 TL= 89.0 .0114 Pf 1.0 Fn 20.2 F Pt 21.3 E q= .0 -------------------------------------------------------------------------- K= .0 L= 29.0 Pt 20.2 Pt 20.2 6 Q= 10.4 F= 4R2B11- F= 21.0 C= 150 Fe .0 Pv -.1 Vei= 3.5 D= 1.101 TL= 50.0 .0201 Pf 1.0 Fri 20.2 F Pt 21.3 -- F -- q= .0 K .0 L= 10.0 Pt 21.3 Pt 21.3 7 Q= 18.0 F= 1B1L F= 12.0 C= 150 Pc .0 Pv -.2 Ve1= 6.1 D 1.101 TL= 22.0 .0558 Pf 1.2 Pn 21.0 G Pt 22.5 q= .0 -------------------------------------------------------------------------- K= .0 L= 7.0 Pt 22.5 Pt 22.5 B Q= 18.0 F 1C4R1S1L 21.0 C= 150 Fe 3.0 ?v -.2 Ve1= 6.1 D 1.101 TL= 28.0 .0558 Pf 1.6 Pn 22.2 H Pt 27.1 H q 5.0 -------------------------------------------------------------------- DOME 5.0 Pt 27.1 Pt 27.1/ 9 Q= 23.0 F= 1G1B2L F= 10.0 C= 150 Pc 1.7 Pv -.5 Ve1= 8.9 D= 1.025 TL= 15.0 .1245 Pf 1.9 Fri 26.6 I Pt 30.7 4/04/211 11:45 6195886805 SYMONS FIRE PROT 1-IYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. PAGE 84/S5 Page 3 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020, Date: 04-04-2011 File: C:\RESDEN43\11-034--A.RES JOB SE'H - TAMARACK PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. GPM FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Et) I .0 K .0 ------------------------------------------------------------------------------- L= 90.0 Pt 30.7 Pt 30.7 10 Q= 23.0 F= 5C F= 5.0 C= 150 Pc .9 Pv -.2 Vel 4.8 D= 1.394 TL= 95.0 .0279 Pf 2.6 Pn 30.5 Pt 34.2 .0 K .0 L 20.0 Pt 34.2 Pt 34.2 11 Q= 23.0 F= 2C F= 4.0 C= 150 Pc 1.3 Pv -.6 " Vel= 9.5 D= .995 TL= 24.0 .1439 ?f 3.5 Pn 33.6 K Pt 39.0 -------------------------------------------------------------------------- Meter = 3.0 12 Q= 23.0 <<< --------------------------------------------------------------------------- SOURCE >>> Pt 42.0 E=>45-Eib L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPig S>SwgChk G=>GatVlv 04/04/2011 11:45 6195886805 SYMONS FIRE PROT PAGE 05/05 1IYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEER; SYMONS FIRE PROTECTION.. (619) 588-6364. ADDRESS 1050 Pioneer way, Suite R, El Cajon CA 92020. DATE : 04-04-2011 FILE : C:\RESDEN43\11-034-A.RES JOB : SFH - TAMARACK PSI FIRE SPRINI<LER HYDRAULIC GRAPH 100 --- 90 -0 80 ----- 70 -•---•- ___ .. _____..- -, _____ ________ - ______ 60--- 50 30 -_/_ 20 10 10 15 20 25 30 35 40 45 50 FLOW - Gptn 0 Supply Curve I- • Demand Curve Static : 85.0 Avi Pr : 84.0 @ 22 Rsid : 84.0 Req Pr : 42.0 @ 22 Flow 23.0 Fr Cush: 42.0 Copyright: Hydronics Engineering, 2002. 34119 Fremont Bi, Suite 609, Fremont, CA. 94555. (510) 487-9160. Bulletin 006 Rev.D A Concealed Residential Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2.1/2" (13mm) Total adjustment. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW - Product Description Model RFC43 and RFC49 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive appearance and ½" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 and RFC49 are UL Listed Residential Sprinklers to be installed in the residential portions of any occupancy in accordance with NFPA. 13, 13R, & 13D. The RFC43 and RFC49 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43 and RFC49, for residential installations, use a 165°F (74°C) fusible solder link in a tuning fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Cover assemblies provide up to 3ç' (13mm) of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. For the push-on/thread-off option, the cover assembly is pushed onto the cup and final adjustment is made by turning the cover clockwise until the skirt flange makes full contact with the ceiling. Cover removal requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate Max. Ambient I Temp. 165°F/74°C 135°F/57°C 100°F/380C Installation Data: RFC43 (SIN RA0612) Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch (mm) Factor Spacing ft. (m) Distance to Wall ft. (m) Distance between sprinklers, ft. (m) -- Flow Press. gpm (Lpm) psi (bar) ½" (15mm) 43 12 x 12 (3.6x3.6) 6 (1.83) 8(2.43) 12(45) 7.8(0.54) 1/2 (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 9.1 (0.63) 1," (15mm) 4.3 16 x 16 (4.9x4.9) 8 (2.43) 8(2.43) 13 (49) 9.1 (0.63) 1/2" (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 18(68) 17.5(l.21) ½" (15mm) 4.3 20 x 20 (6.0x6.0) 10(3.05) 8(2.43) 21(79) 23.8 (1.64) Note: 1 bar = 100 Kpa Installation Data: RFC49 (RA0616 Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch (mm) Factor Spacing Distance Distance between ft. (m) to Wall ft. (m) sprinklers, ft. (m) Flow Press. gpm (Lpm) psi (bar) Y2" (15mm) 49 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 13 (49) 7.0(0.48) 1/2 (15mm) 4.9 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 7.0(0.48) ½" (15mm) 4.9 16 x 16 (4.9x4.9) 8(2.43) 8(2.43) 13(.4 7.0(0.48) 1/2 (15mm) 4.9 18 x 18 (5.5x5.5) 9(2.74) 8 (2.43) 17 (64.3) 12.0(0.83) 11211(15mm) 4.9 20 x 20 (6.0x6.0) 10(3.05) 8 (2.43) 20(75.7) 16.7 (1.14) Note: 1 bar = 100 Kpa 11 FOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN o1 Maintenance Model RFC43 and RFC49 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. 135°F (570C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a ½" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty—specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulletin 006). Model RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05 gprnft2. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3(62.4), having a 7/16" orifice. Temperature rating shall be Ordinary 165°F (740C); cover plate temperature rating to be Ordering Information Specify: Sprinkler Model Cover Plate Finish Thread-On or Push-On Feature Cover Plate Finishes W Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome " Other colors and finishes available. Consult factory for details. Note: Paint -or any other coatings applied over the factory finish Will void all approvals and warranties. 1" x 1/2" REDUCING TEE OR ELBOW _+. 6. 7mm) 01.4. " [58.7mm] 0/A - HOLE IN CEILING CUP 2"(6 To FACE OF CEILING 2" (50.8mm] MAX. FACE OF FITTING %•. .' ' ' DIMENSION CEILING " [12.7mm] I COVER ADJUSTMENT / 01.4. PLAT COVER 18 -M] [4.8mm] ASSEMBLY X61l COVER PLATE: 1/2" [12.7mm] ADJUSTMENT t11CL1 Fire Suppression & Building Products Technical Services 800-381-93121+1-401-781-8220 www.tyco-fire.com Series TY-FRB — 2.8,F 4,2,9 56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version. of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling; This recessed pendent sprinkler uses one of the following, A two-piece Style 10 (1/2 inch NPT) or Style 40(3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 Inch NPT) Recessed Escutcheon with 1/4 Inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause- the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Pagf I of 10 Corrosion-resistant coatings, where applicable, are utilized to extend the life at copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approial agencies, the testing Is not representative of all possible cor- rosive atmospheres. Consequently, It is recommended that the end user -be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TV- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The Installing contractor or sprinkler manu- facturer should be contacted with any questions. JULY 2010 Model/Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2- NPT TY1231: Pendent 2.81K, 112NPT TY2131: Upright . 4.21K, 1/2NPT TY2231: Pendent 4.21K, 1/2" NPT TY3131: Upright 5.61K, 1/2 NPT TY3231: Pendent 5.61K, 112" NPT TY4131: Upright. 8.0K, 3/4" NPT TY4231: Pendent . 8.0K, 3/4" NPT TY4831: Upright* 8.01K, 1/2 NPT TY4931: Pendent* 8.0K, 1/2" NPT Eastern Hemisphere Sales Only TFPI7I ESCUTCHEON STYLE 10 or 20 PLATE SEATING - -RECESSED NPT SURFACE ESCUTCHEON 7 2-3/16' r (55.6 mm) _ SSP DEFLECTOR* '- 2-7/V'(73,0 mm) DIA. PENDENT RECESSED PENDENT TFP71 Page 2 of 10 7/16'(11,1 mm) ESCUTCHEON. STYLE 10 0r20 NOMINAL PLATE SEATING RECESSED SSU MAKE-IN 1/2 SURFACE ESCUTCHEON DEFLECTOR NPT 6' 4 I (11,1 mm) ______ 2-1/4' NOMINAL (57,2 mm) 5••UW 5,6 mm) , 2-- j MAKE-IN (5 WRENCH (39,7 mm) " 2-3/16' .-- 1-9/16' J 1 -- FLATS 1/2° NPT SSP DEFLECTOR* I- 2-7/8' (73,0 mm) DIA. -I CROSS SECTION.; ' UPRIGHT PENDENT. - RECESSED PENDENT 1 - Frame 3-Sealing 4-Bulb 6-Deflector * Assembly Temperature rating is Indicated on deflector or adjacent to 2 - Button 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 5 4 2 3 1 7/16' (lii mm) - - - NOMINAL SSU* MAKE-IN DEFLECTOR 7/16° I (11,1 mm) I NOMINAL I MAKE-IN 2-3/16' WRENCH FLATS cc (55,6 mm) 1/2' NPT CROSS SECTION UPRIGHT 1 -Frame 3 . Sealing 4-Bulb 6- Deflector Assembly - Temperature rating Is indicated on deflector or adjacent to Compression orifice seat on frame. 2- Button Screw FIGURE 2 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY2131) AND PENDENT (TV2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT SSU * DEFLECTOR CROSS SECTION UPRIGHT 3/4 NOT TFPI7I Page 3 of 10 7/16'(11,1 mm) ESCUTCHEON STYLE 10 or 20 ssu NOMINAL 1I2 PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 4 NOMINAL (55,6 mm) 2 W-3/1 1-1/2" 6 (55,6 mm) RENCH FLATS 1/2 NPT SSP DEFLECTOR * 2-7/8 (73,0 mm) DIA. - CROSS SECTION ' UPRIGHT PENDENT RECESSED IENDENT 1 - Frame 3- Sealing 4-Bulb 6- Deflector Assembly • Temperature rating is indicated on deflector or adjacent to 2 - Button - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY3131) AND PENDENT (TV3231) SPRINKLERS 5.6K-FACTOR, 1/2 INCH NPT 1/2'(12,7 mm) ' ESCUTCHEON STYLE 30 or 40 NOMINAL PLATE SEATING JECESSED MAKE-IN SURFACE ESCUTCHEON NPT 2t 5/16 (58,7 mm) 1-9/16 I - (39.7 mm) SSP DEFLECTOR * L- 2-7/8"p3,0 mm) DIA. PENDENT RECESSED PENDENT - Frame 3-Sealing 4-Bulb 6- Deflector Assembly Temperature rating is indicated ondeflector or adjacentto - ompression orifice seat on frame. 2- Button Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT ('TY4131) AND PENDENT (TV4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT TFPI7I Page 4 of 10 7/16 (11,1 mm) SSU NOMINAL DEFLECTOR MAKE-IN 1/2 I5 I NOMINAL f (57,2 mm) (11,11 mm) 2-1/4° NPT MAKE-IN 1-9/16 2-3/16° I _- (55,6 mm) ______ WRENCH (39,7 mm) -- FLATS ssP* CROSS /2"NPT DEFLECTOR SECTION UPRIGHT PENDENT. 1 -Frame 3 - Sealing 4 - Bulb 6 - Deflector 'Temperature rating is indicated on deflector or adjacent to - Assembly - Compression orifice seat on frame. 2 - Button Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS &O K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval Information Including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi"2 (40,3 LPM/bar"2) K=4.2 GPM/psi'/2 (60,5 LPM/bar"2) K=5.6 GPM/psi'/2 (80,6 LPM/bar"2 K=8.0 GPM/psi'/2 (115,2 LPM/bar"2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button .............. Brass/Copper Sealing Assembly.........Beryllium Nickel w/Teflonf Bulb ......................Glass Compression Screw........Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze t Registered Trademark of Dupont Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE: Do not Install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C and 3/32 Inch (2,4 mm) for the 2860F/1410C temperature ratings. Obtairy a leak-tight 1/2 inch NPT sprin-kler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The SerieS TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Install Pendent sprinklers in the. pendent position. Install upright sprinklers in the upright position. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I WHITE*** J POLYESTER 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135"F/57'C Orange 1, 2, 3, 4 155'F/68°C Red 175°F/790C Yellow 200"F/93°C Green 286°F/141'C Blue RECESSED PENDENT (TY1231)" Figure 6 135"F/570C Orange 1,2,4 155°F/68"C Red 175°F/790C Yellow 200"F193"13 Green RECESSED PENDENT (1Y1231)** Figure 7 13ó"F/57"C Orange 155°F/68"C Red 175°F/79°C Yellow 200"F/93"C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/570C Orange - 1,2 155"F/68°C Red 175"F/79°C Yellow 200"F/93°C Green 286"F/141°C Blue RECESSED (TY2231)* Figure 8 135"F/57°C Orange PENDENT 155"F/68'C Red 175"F/79°C Yellow 200"F/93"C Green RECESSED PENDENT (TY2231)** Figure 9 135°F/57°C Orange 155°F/68°C Red 175"F/79"C Yellow 200"F/93"C I Green NOTES: 1, Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. - - Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and CUL Listed, thesprinkIers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME J PLATED I WHITE*** POLYESTER LEAD COATED 5.6 112" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135F/57"C Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 3, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/930C Green 286"F/141"C RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2, 4,5 286"F/141"C N/A 155"F/68°C Red 175"F/79"C Yellow RECESSED PENDENT (TY3231)** Figure 11 135°F/5PC - 200°F/93"CM Green 1,2,3, 4, 5 Blue . N/A 155"F/68"C 175F/79"C 200°F/93°C 286"F/141°C 8.0 - 3/4" NPT PENDENT (TY4231) and UPRIGHT (1Y4131) 15"F/57*C Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 5 1550F1680C Red 175°F/79°C Yellow 200°F/930C Green 286"F/141°C RECESSED PENDENT - (TY4231)* Figure 12 135"F/57"C Orange 1, 2, 5 ' - Blue N/A s 155"F/68"C Red 175 C "F/79" ' Yellow 200"F/93°C Green 286"F/141C RECESSED PENDENT (TY4231)** Figure 13 135°F/57*C Orange 1,2.3,5 Blue N/A 155"F/68"C Red 175"F/79"C Yellow 200"F/93°C Green 286°F/1410C 80 - 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135"F/57°C Orange - 1, 2, 4, 5, 6 Blue 1, 2, 5 155"F/68"C Red 1750F/79"C Yellow - 200°F/93"C Green 286°F/141"C NOTES: Listed by Underwriters laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters laboratories. Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53.428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. S. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2' NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8. K-FACTOR SPRINKLERS TFPI7I1 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME I WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1I3I) 1/2" NPT 75 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (1Y2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) - RECESSED (SEE NOTE 1) PENDENT (TY3231) N/A PENDENT (TY4231) ' 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (1Y4931) 175 PSI -1/2" - NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) - - (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. The Series TY-FRB Recessed Pendent Sprinklers must be Installed in accor- dance with the following instructions. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler Into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TV-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes In contact with the ceiling. TABLE C MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: were modified or over-heated. were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. are leaking or exhibiting visible signs of corrosion. were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. 2-7/8° DIA. (73,0 mm) 1/2"_(12,7 mm) 2-1/4° DIA. __•• 1/4 (6,4 mm) 7.2 mm) MOUNTING PLATE 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 1-5/16 (33,3 mm)l TY-FRB 1-1/16.(27,0 mm) FIGURE 7 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON -. 2.8 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm) FACE OF PRINKLER FITTING 2-7/8" DIA. (73,0 min) 1/2",(l 2,7 mm) 1/4" (6.4 mm) (57.2 Min) I 2-1/4' DIA. I I MOUNTING I PLATE f \ MOUNTING SURFACE CLOSURE 1-1/4"(31,13 mm) - 1'(25,4 mm) FIGURES SERIES TY-FRB RECESSED .PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 8 of 10 2-7/8° DIA. 5/8±1/4° (7310 mm) I 3/4°_(19,1 mm) (15,9±6,4 mm) 2-1/4° DIA. I 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8° , (3,2 mm) MOUNTING SURFACE,,/" I , t CLOSURE SERIES 1-5/16° (33,3 min)1 TY-FRB - 13/16' (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 28K-FACTOR, 1/2 INCHNPT 2-7/8' DIA. (73,0mm) I 5/8±1/4' 3/4"(19,1 mm) I (15,9±6,4 mm) 2-1/4° DIA. — 1/4(6,4 mm) I (57,2 mm) "•I I FACE OF MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING / / SURFACE/ SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB - 3/4'419,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 42K-FACTOR, 1/2 INCH NPT Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility ties with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices In compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the Sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be. replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify - the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. 2-7/8"DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) - (12,7±3,2 mm) 2-1/4" DIA. I - I 4'6,4 mm)l FACE OF (57.2 mm) I MOUNTING SPRINKLER - PLATE FIlliNG 1/8' (3,2 mm) \ -U.--- - MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 1' 25,4 mm) 2-7/8" DIA. (73,0 mm) 3/4" (19,11mi) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING I 01 ATr 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE A CLOSURE SERIES 1-1/4' (31,8 mm) 3/4" (19,1 mm) 2-7/8' DIA. (73.0 mm) 3/4'(19,1 mm) -ii:-•--i 2-1/4" DIA. 1/4' (6,4 mm) I (57,2 mm) MOUNTING _- PLATE 1/2±1/8' (12,7±3,2 mm) FACE OF SPRINKLER FITTING I MOUNTING SURFACE TP1l7 Page 9 of 10 FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6K-FACTOR, 1/2 INCH NPT 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3 mm) TY-FRB 13/16'-(20,6 mm) FIGURE 12 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON ao K-FACTOR, 3/4 INCH NPT FIGURE 11 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE20 RECESSED ESCUTCHEON 5.6.11-FACTOR, 1/2 INCH NPT 2-7/8" DIA. " (73,0 mm) 1/2'(12,7 mm) 2-1/4" DIA. I 1/4" (6,4 mm) (57,2 mm) -Ti I MOUNTING - DI AT k(3 m) CLOSURE SERIES 1-5/16'(33,3mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT.. WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH 1 I NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)' 9 CHROME PLATED 7 LEAD COATED * Eastern Hemisphere sales only. TFPI7I Page 10 of 10 P/N 57- XXX- X- XXX MODEL/SIN SPRINKLER FINISH 330 2.8K UPRIGHT (1/2°NPT) TY1131 331 2.8K PENDENT (1/2°NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.21K PENDENT (1/2°NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.61K PENDENT (1I2NPT) TY3231 390 8.0K UPRIGHT (314'NPT) TY4131 391 8.0K PENDENT (314"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2°NPT) TY4931° TEMPERATURE RATINGS 135 135-F (57-C) 155 155-F (68'Q 175 175-F (79-C) 200 200°F(93°C) 286 286°F (141°C) TABLED PART NUMBER SELECTION SERIES TV-FRB PENDENT AND UPRIGHT SPRINKLERS Limited responsible for sprinkler system design Ordering errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's Warranty representatives. Procedure Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects In material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBR No warranty is given forprod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired orreplaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed .about the possibility of suth damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made In lieu of any pnd all other warranties. express or imolled, including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect In products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The Invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Contact your local distributor for availability. When placing an order, Indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish oroating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40 Recessed Escutcheon with (specify* finish, P/N (specify. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, PIN 56-850-4-001. * Refer to Technical Data Sheet TFP770. Copyright 0 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved.