Loading...
HomeMy WebLinkAbout421 TAMARACK AVE; ; AS110139; Permit6/20/24, 8:52 AM AS 110139 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS110139 Job Address: 421 TAMARACK AV Permit Type: SPRINK Parcel No: 2060420200 Status: ISSUED Applied 9/28/2011 Approved: 9/27/2011. Lot#: .0 Reference No.: Issued: 9/27/2011 PC #: . Inspector: Project Title: URBINO RESIDENCE SINGLE FAMILY RESIDENCE - ADDITION OF 7055 S.F. (incl. 2nd FL) Applicant: SYMONS FIRE PROTECTION SUITE 1050 PIONEER WAY EL CAJON, CA 619-588-6364 Owner: ALDERSON REVOCABLE TRUST 05-29-02 1122 COUNTRYWOOD LN VISTA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 393 . 0 393 0 about:blank Ill Parsley Consulting 350 West 91 Avenue, Suite 206 E80JiJ0, California 92025-5053 Tc10k0 (760) 745-6181 F(760) 745-0537 September 26, 2011 Fire Code Official City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Urbino Residence, 421 Tamarack Avenue, Carlsbad, CA Dear Sir: We have reviewed the submittal as prepared by Symons Fire. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required. Sincerely, PARSLEY Renneth W. WagonerT Office Manager End (1) Working Drawings - 3 sets Hydraulic Calculations - 3 sets Review Comments - I set Note: A copy of this letter has been transmitted via e-mail to Symons Fire on September 26, 2011 file:\C:\Docurnents and Settings\Ken\Rev2 I 1263.00J.wpd Urbino Residence Review Comments. Page 2 Review Comments Urbino Residence, 421 Tamarack Avenue, Carlsbad, CA 1. Field verify that the workshop on the 2 floor is a conditioned space, or the sprinklers in that space must be intermediate temperature. The following comments are for your information and will appear on every residential sprinkler review. The alarm bell must be capable of being heard, above background noise, with doors closed, in all living areas of the residence. This will be checked at final acceptance. Pressure required at base of riser will be verified to be available at time of final acceptance. Sprinkler heads are omitted from bathroom areas under 55 SF in area with noncombustible plumbing fixtures. Fixtures will be verified at final acceptance. Sprinkler head blockage or pattern disruption caused by beams or other obstructions will be verified to not exist at final acceptance inspection. Sprinkler heads should be located the proper distance from heat sources (stoves, kitchen ranges, fireplaces, heat diffusers, etc.) This will be checked at final acceptance inspection. Sprinkler heads located in an unconditioned space (garage, water heater closet, etc.) should be fast response type with an appropriate temperature rating, commercial heads are acceptable in these areas. All exposed piping shall be black steel or copper. Concealed piping can be CPVC plastic. ( HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. A8 i LICENSE : 682025 APP SSUBMgTTE DESIGNER : CANDI. CAUDILLO DATE : 09-14-2011 CARUS RE DEPAR M FILE : 11-136 JOB NAME : URBINO RESIDENCE 161 FLAT LOCATION : 421 TAMARACK AVE. CARLSBAD, CA 92008 These II:ins ho'e been re eed lot appaiflt coittphauice with [tic cuitcnt applicihle codes and standards in louce in the jurisdictiori. The owner or contract(w may .itilt,c ktttmon for a huildtn DESIGN DATA I hi. re' tew in ¼itppotl ot at app1 pen iii s th the rprcss utder.i;uiU!iflg that this revics he owner or contractor or their in to w:u' relics en engineer or altlIiteet for sole msronihtl1t% DESIGN CRITERION: N FPA ]_ 3 - foi lull cutnupIanee with s.tid codes and standards. lie hI!ultlOt odc Or tOt IUW respollsihiltv tin juL lu&ltit't dcfktCtcIcs. rout s. omissions it neglteiice in these MIN S PR FLOW 13 Gpm plaii WhitliCI or not noted in ihis review. ;ucff ( Reviewer: AREA PER SPRINKLER : 256 Sq Ft lEC()MMENDAPPROVAL TOTAL CALCULATED AREA 512 Sq Ft 0 I:c)NINIEN D APIR(WAI.. AS NOTED TOTAL SPRINKLERS CALCULATED : 2 Heads FLOW DATA. TOTAL SPRINKLER FLOW : 26.1 Gpm DOMESTIC DEMAND : 5.0 Gpm TOTAL WATER REQUIRED : 31.1 Gpm BASE OF RISER NODE: 15 FLOW: 31.1 Gpm PRESSURE: 29.9 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DEPARTMENT PHONE : (760) 602-4666 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. I 'ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 09-14-2011 File: C:\RESDEN43\11-136.RES JOB : URBINO RESIDENCE 16'FLAT Page 1 SOURCE I STATIC : 85.0 Psi RESIDUAL : 84.0.Psi. FLOW : 31 Gpm DESIGN I SPRINKLER MANUF : TYCO MODEL : LFII I SPRINKLER Q : .0 Gpm VALVE : 12.0 Psi - I SPRINKLER P : .0 Psi METER : 4.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm 1 28.0 4.9 7.0 13.0 2 28.0 4.9 7.2 13.1 3 28.0 7.6 4 25.0 11.8 5 25.0 10.7 6 25.0 12.3 7 28.0 11.7 8 28.0 10.8 9 28.0 11.9 10 15.0 18.4 11 15.0 20.4 12 15.0 19.8 13 15.0 21.7 14 15.0 24.3 15 9.0 29.9 5.0 DOME 16 5.0 34.9 17 3.0 37.5 18 3.0 49.5 19 3.0 50.2 20 .0 SOURCE 61.6 31.1 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 512 Sq Ft REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .051 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 26.1 Gpm TOTAL DOMESTIC FLOW : 5 Gpm TOTAL WATER REQUIRED : 31.1 Gpm TOTAL SPRINKLER PRESS : 45.6 Psi WATER METER LOSS : 4.0 Psi VALVE FIXED LOSS : 12.0 Psi Copyright (2002) SUPPLY PRESS AVAILABLE : 84.0 Psi by DEMAND PRESS REQUIRED : 61.6 Psi Hydronics Engineering PRESSURE CUSHION 22.4 Psi 34119 Fremont Bi, Suite 609 Fremont, Ca., 94555 MAXIMUM HYDRDNICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 09-14-2011 File: C:\RESDEN43\11-136.RES JOB : URBINO RESIDENCE 16'FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) - 1 q= 13.0 K= 4.9 L= 7.0 Pt 7.0 Pt 7.0 1 Q= 13.0 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1 Ve1= 4.4 D= 1.101 TL= 19.0 .0305 Pf .6 Pn 6.9 3 Pt 7.6 2 q= 13.1 K= 4.9 -------------------------------------------------------------------------- L= 2.0 Pt 7.2 Pt 7.2 2 Q= 13.1 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1 Ve1= 4.4 D= 1.101 TL= 14.0 .0311 Pf .4 Pn 7.0 3 Pt 7.6 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 22.0 Pt 7.6 Pt 7.6 3 Q= 17.7 F= 2B3L F= 31.0 C= 150 Pe 1.3 Pv -.2 Ve1= 6.0 D= 1.101 TL= 53.0 .0542 Pf 2.9 Pn 7.4 4 Pt 11.8 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 70.0 Pt 7.6 Pt 7.6 4 Q= 8.4 F= 5R3B2E6L 64.0 C= 150 Pe 1.3 Pv -.1 Ve1= 2.8 D= 1.101 TL= 134.0 .0137 Pf 1.8 Pn 7.5 5 Pt 10.7 - 5 q= .0 K= .0 L= 49.0 Pt 10.7 Pt 10.7 5 Q= 8.4 F= 2R2B6L F= 54.0 C= 150 Pe -1.3 Pv -.1 Ve1= 2.8 D= 1.101 TL= 103.0 .0137 Pf 1.4 Pn 10.7 8 Pt 10.8 8 q= .0 K= .0 -------------------------------------------------------------------------- L= 51.0 Pt 10.8 Pt 10.8 6 Q= 8.4 F= 2R2B2E2L F= 28.0 C= 150 Pe .0 Pv -.1 Ve1= 2.8 D= 1.101 TL= 79.0 .0137 Pf 1.1 Pn 10.8 9 Pt 11.9 4 q= .0 K= .0 -------------------------------------------------------------------------- L= 64.0 Pt 11.8 Pt 11.8 7 Q= 5.5 F= 6R2B F= 16.0 C= 150 Pe .0 Pv .0 Ve1= 1.9 D= 1.101 TL= 80.0 .0062 Pf .5 Pn 11.8 6 Pt 12.3 6 q= .0 K= .0 -------------------------------------------------------------------------- L= 64.0 Pt 12.3 Pt 12.3 8 Q= 5.5 F= 4R6L2B F= 56.0 C= 150 Pe -1.3 Pv .0 Ve1= 1.9 D= 1.101 TL= 120.0 .0062 Pf .7 Pn 12.3 H 7 Pt 11.7 7 q= .0 K= .0 -------------------------------------------------------------------------- L= 21.0 Pt 11.7 Pt 11.7 9 Q= 5.5 F= 1R2B F= 11.0 C= 150 Pe .0 Pv .0 Ve1= 1.9 D= 1.101 TL= 32.0 .0062 Pf .2 Pn 11.7 9 Pt 11.9 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 09-14-2011 File: C::\RESDEN43\11136.RES JOB : URBINO RESIDENCE 16!FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAJ4ETER . TOTAL (Psi/Ft) 4 q= .0 K= .0 L= 54.0 Pt 11.8 Pt 11.8 10 Q= 12.2 F= 2R2L3B F= 31.0 C= 150 Pe 4.3 Pv -.1 Vel= 4.1 D= 1.101 TL= 85.0 .0272 Pf 2.3 Pn 11.7 10 Pt 18.4 9 q= .0 K= .0 -------------------------------------------------------------------------- L= 31.0 Pt 11.9 Pt 11.9 11 Q= 13.9 F= 1R3L2B F= 32.0 C= 150 Pe 5.6 Pv -.1 Vel= 4.7 D= 1.101 TL= 63.0 .0347 Pf 2.2 Pn 11.8 12 Pt 19.8 10 q= .0 K= .0 -------------------------------------------------------------------------- L= 52.0 Pt 18.4 Pt 18.4 12 Q= 12.2 F= 4R33 F= 19.0 C= 150 Pe .0 Pv -.1 Vel= 4.1 D= 1.101 TL= 71.0 .0272 Pf 1.9 Pn 18.3 11 Pt 20.4 11 q= .0 K= ..0 -------------------------------------------------------------------------- L= 34.0 Pt 20.4 Pt 20.4 13 Q= 12.2 F= 4R2B F= 14.0 C= 150 Pe .0 Pv -.1 Vel= 4.1 D= 1.101 TL= 48.0 .0272 Pf 1.3 Pn 20.3 13 Pt 21.7 12 q= .0 K= .0 -------------------------------------------------------------------------- L= 36.0 Pt 19.8 Pt 19.8 14 Q= 13.9 F= 2R1L2B F= 19.0 C= 150 Pe .0 Pv -.1 Vel= 4.7 D= 1.101 TL= 55.0 .0347 Pf 1.9 Pn 19.6 13 Pt 21.7 13 q= .0 K= .0 -------------------------------------------------------------------------- L= 10.0 Pt 21.7 Pt 21.7 15 Q= 26.1 F= 1R1B1L F= 13.0 C= 150 Pe .0 Pv -.5 Vel= 8.8 D= 1.101 TL= 23.0 .1112 Pf 2.6 Pn 21.2 14 Pt 24.3 14 q= .0 K= .0 -------------------------------------------------------------------------- L= 6.0 Pt 24.3 Pt 24.3 16 Q= 26.1 F= 1C4R1S1L F= 21.0 C= 150 Pe 2.6 Pv -.5 Vel= 8.8 D= 1.101 TL= 27.0 .1112 Pf 3.0 Pn 23.7 15 1Pt 29.9 15 q= 5.0 DOME -------------------------------------------------------------------------- L= 5.0 Pt 29.9 Pt 29.9 17 Q= 31.1 F= 1G2L1B F= 10.0 C= 150 Pe 1.7 Pv -1.0 Vel= 12.1 D= 1.025 TL= 15.0 .2179 Pf 3.3 Pn 28.9 16 Pt 34.9 16 q= .0 K= .0 -------------------------------------------------------------------------- L= 200.0 Pt 34.9 Pt 34.9 18 Q= 31.1 F= 10C F= 10.0 C= 150 Pe .9 Pv -.1 Vel= 3.2 D= 2.003 TL= 210.0 .0083 Pf 1.8 Pn 34.8 17 Pt 37.5 17 Q= 31.1 -------------------------------------------------------------------------- Pt 37.5 BFP FIXED PRESSURE LOSS Valve 12.0 18 Pt 49.5 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 4 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 09-14-2011 File: C:\RESDEN43\11-136.RES JOB : URBINO RESIDENCE 161 FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) --------------------------------------------------------------------------- 18 q= .0 K= .0 L= 2.0 Pt 49.5 Pt 49.5 20 Q= 31.1 F= 1C F= 1.0 C= 150 Pe .0 Pv -1.0 Vel= 12.1 D= 1.025TL= 3.0 .2179 Pf .7 Pn 48.5 19 Pt 50.2 -------------------------------------------------------------------------- 19 q= .0 K= .0 L= 20.0 Pt 50.2 Pt 50.2 21 Q= 31.1 F= 2C F= 4.0 C= 150 Pe 1.3 Pv -1.1 Vel= 12.8 D= .995 TL= 24.0 .2518 Pf 6.0 Pn 49.1 20 Pt 57.6 -------------------------------------------------------------------------- Meter = 4.0 -------------------------------------------------------------------------- Q= 31.1 <<< SOURCE >>> Pt 61.6 -------------------------------------------------------------------------- E=>45-Elb L=>90-E1b B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. DATE : 09-14-2011 FILE : C:\RESDEN43\11-136.RES JOB : URBINO RESIDENCE 161 FLAT PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 90 80 70 60 — 'ft 50 - 30 20 10 10 15 20 25 0 Supply Curve Static : 85.0 Resid : 84.0 Flow : 31.0 30 35 40 45 50 FLOW - Gpm Demand Curve Avi Pr : 84.0 @ 31 Req. Pr : 61.6 @ 31 Pr Cush: 22.4 Copyright: Hydronics Engineering, 2002. 34119 Fremont Bi, Suite 609, Fremont, CA. 94555. (510) 487-9160. Lb tqCa Rre Suppression I & Building Products I Irapid responses Technical Services 800-381-9312 +1-401-781-8220 HOME FIRE SPRINKLER SYSTEM www.tyco-fire.com I Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 49 K-Factor General Description The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are decora- tive, fast response, fusible solder sprin- klers designed for use in residential oc- cupancies such as homes, apartments, dormitories, and hotels. The Cover Plate/Retainer Assembly con- ceals the sprinkler operating compo- nents above the ceiling. The flat profile of the Cover Plate provides the optimum aesthetically appealing sprinkler design. Additionally, the concealed design of the Series LFII Residential Flat-Plate Con- cealed Pendent Sprinklers provides 1/2 inch (12;8 mm) vertical adjustment. This adjustment provides a measure of flex- ibility when cutting fixed pipe drops. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are in- tended for use in the following systems: per NFPA 13D, wet pipe residential sprinkler systems for one- and two- family dwellings and mobile homes; per NFPA 13R, wet pipe residential sprinkler systems for residential oc- cupancies up to and including four stories in height; and per NFPA 13, wet pipe sprinkler sys- tems for the residential portions of any occupancy. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. The Series LFII Residential Flat-Plate Concealed Pendent Sprinkler has a 4.9 (60,5) K-factor that provides the required residential flow rates at reduced pres- sures, enabling smaller pipe sizes and water supply requirements. This sprinkler has been designed with heat sensitivity and water distribution characteristics proven to help in the con- trol of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap protects the sprinkler during ceiling installation or finish. After ceiling installation is com- plete, the Protective Cap is removed and the Cover Plate/Retainer Assem- bly is installed. Removing the Protec- tive Cap is required for proper sprinkler performance. Ii'L.Jt(.1 The Series LFII Residential Rat-Plate Concealed Pendent Sprinklers (TY2524) described herein must be installed and maintained in compliance with this doc- ument and with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The in- stalling contractor or sprinkler manu- facturer should be contacted with any questions. Model/Sprinkler Identification Number (SIN) TY2524 Technical Data Approvals UL and C-UL Listed NSF-61 Certified The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi"2 (70,6 LPM/bar Temperature Rating Sprinkler: 160°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment 112 inch (12,7 mm) Finishes Refer to the Ordering Procedure section. Physical Characteristics Cover Plate/Retainer Assembly: Cover Plate .............Copper Ejection Spring .... Stainless Steel Retainer ................Brass Page 1 of 6 OCTOBER 2010 TFP443 TFP443 Page 2 of 6 Horizontal Ceiling. Sloped Ceiling Sloped Ceiling Minimum Flowib) and Minimum Flow' and Minimum Flowla) and Residual Pressure Residual Pressure Residual Pressure Maximum Maximum (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise Coverage Spacing for 12-inch run) up to maximum 4-inch up to maximum 8-inch Area a) rise for 12-inch run) rise for 12-inch run) 160°F (71°C) 160°F (71°C) 160°F (71°C) Sprinkler Sprinkler Sprinkler 12'x 12 12 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (3,7 in x 3,7 m) (3,7 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0.83 bar) 14'x 14' 14' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (4,3 in 4,3 m) (4,3 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 16' x 16' 16' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64.3 LPM) (4,9 m x 4,9 m) (4,9 m). 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 18' x 18' 18' 17 GPM (64,3 LPM) 22 GPM (83,3 LPM) 22 GPM (83,3 LPM) (5,5 m x 5,5 m) (5,5 ni) 12.0 psi (0,83 bar) 20.2 psi (1,39 bar) 20.2 psi (1,39 bar) 20'x 20' 20' 20 GPM (75,7 LPM) 24 GPM (90,8 LPM) 24 GPM (90,8 LPM) (6,1 m x 6,1 m) (6,1 m) 16.7 psi (1,15 bar) 24.0 psi (1,65 bar) 24.0 psi (1,65 bar) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to "Hydraulic Design' in the Design Criteria section for details. TABLEA SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS Sprinkler/Support Cup Assembly: Body ...................Brass Cap ...................Bronze Saddle ..................Brass Sealing, Assembly .......Beryllium Nickel w/ Teflon' Soldered Link Halves ......Nickel Lever ..................Bronze Compression Screw .......Brass Deflector ................Bronze Guide Pin Housing........Bronze Guide Pins .............Bronze Support Cup ..............Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup As- sembly. At this point, the Deflector, sup- ported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprinkler/ Support Cup Assembly is comprised of two link halves that are soldered togeth- er with a thin layer of solder. When the rated temperature is reached, the sol- der melts and the two link halves sepa- rate, allowing the sprinkler to activate and flow water. 1 Registered trademark of Dupont Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are UL and C-UL Listed for installation in ac- cordance with the following criteria. L't.1t(.1 When conditions exist that are outside the scope of the provided criteria, re- fer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that maybe accept- able to the Authority Having Jurisdiction. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler op- eration in a fire situation. System Type Only wet pipe systems may be utilized. Hydraulic Design Table A provides the minimum required sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required dis- charge from each of the total number of "design sprinklers" as specified in NFPA 130 or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the .four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: flow rates given in Table A for NFPA 13D and 13R as a function of tem- perature rating and the maximum al- lowable coverage area minimum discharge of 0.1 GPM/ sq. ft. over the "design area" com- prised of the four most hydraulically demanding sprinklers for actual cov- erage areas protected by the four sprinklers Obstruction To Water Distribution Locate sprinklers in accordance with the obstruction rules of NFPA for residential sprinklers as well as obstruction criteria described within TYCO technical data sheet TFP490. Operational Sensitivity Install sprinklers relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprin- klers cannot exceed the length of the coverage area (Table A) being hydrau- lically calculated; for example, a maxi- mum of 12 feet for al2 ft. x 12 ft. cov- erage area or 20 feet for a 20 ft. x 20 ft. coverage area. SPRINKLER- LJPPORT CUP SEMBLY OPERATE SPRINKLE COVER PLATE RETAINE 7/8" (22,2 n 1-1/8" (28,6 WRENCH RECESS .ef PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH DEFLECTOR IN OPERATED POSITION TFP443 Page 3 of 6 BODY SEALING (1/2"NP1) ASSEMBLY CAP SPRINKLER WRENCHING AREA SADDLE 51wP0m h COMPRESSION CUP WITH SCREW ROLL FORMED THREADS LEVER GUIDE PIN SOLDER LINK / ELEMENT GUIDE PIN HOUSING DEFLECTOR / I r__ DEFLECTOR '-' POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD-INTO RETAINER SUPPORT CUP H WITH THREAD UNTIL MOUNTING H - DIMPLES SURFACE IS r FLUSH WITH J EJECTION CEILING SPRING SOWER' COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) ASSEMBLY 2-1/2" DIA. mm) FACE OF 1/2"THREADED SPRINKLER NPT ADJUSTMENT - FilliNG I J k L 635mrn 1I2(,27 - L (47,6 mm 1/8 GAP I 3,2 mm) (3,(3,2 mm) I COVER- SPRINKLER- J MOUNTING RETAINER SUPPORT CUP ' SURFACE ASSEMBLY ASSEMBLY (48 mm) - 3-3/16" DIA. / DISPOSABLE (81,0 mm) TIP PROTECTIVE CAP FIGURE 3 PROTECTIVE CAP AND ACTIVATED DEFLECTOR INSTALLATION DIMENSIONS TFP443 Page 4 of 6 Installation The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must be installed in accordance with the following instructions. NOTICE Damage to the Solder Link Element dur- ing installation can be avoided by han- dling the sprinkler by the Support Cup only; that is, do not apply pressure to the Solder Link Element (Figure 1). Obtain a leak-tight 1/2 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 7 to 14 ft.-lbs. (,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Cover Plate! Retainer Assembly by under- or over- tightening the sprinkler Re-adjust the position of the sprinkler fitting to suit. Install pendent sprinklers in the pendent position, with the center- line of the sprinkler perpendicular to the mounting surface. Remove the Protective Cap. With pipe-thread sealant applied to the pipe threads,. and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler! Support Cup Assembly into the fit- ting. The W-Type 18 Wrench ac- cepts a 1/2 inch ratchet drive. Replace .the —Protective —Cap by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent dam- age to the Deflector and Guide Pins during ceiling installation and/ or during application of the finish coating of the ceiling. As long as the protective Cap re- mains in place, the system is con- sidered "Out Of Service". After the ceiling has been• com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Screw on the Cover Plate/Retainer Assembly until its flange contacts the ceiling. Do notcontinue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Mounting Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524) must be maintained and serviced in accordance with the following instructions. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. were modified or over-heated. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it con- trols, obtain permission to shut down the affected fire protection system from the proper authorities and notify all person- nel who maybe affected by this action. When properly installed, there is a nomi- nal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceil- ing, as shown in Figure 3. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover —Plate-to helpassure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does NOT seal off any of the air gap. Failure to do so may impair sprinkler operation. Absence of a Cover Plate can delay the sprinkler operation in a fire situation. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Exercise care to avoid damage to sprin- klers before, during, and after installa- tion. Never paint, plate, coat, or other- wise after automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cover plates with factory-painted units. Non- factory applied paint can adversely de- lay or prevent sprinkler operation in the event of a fire. TFP443 Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the orig- inal Buyer for ten (10) years against de- fects in material and workmanship when paid for and properly installed and main- tained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defec- tive shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection witb the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete in- formation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in con- tract, tort, strict liability or under any oth- er legal theory, for incidental, indirect, special or consequential damages, in- cluding but not limited to labor charg- es, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or imglied.. including warranties of mer- chantability and fitness for a particular ouroose. This limited warranty sets forth the ex- clusive remedy for claims based on fail- ure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any oth- er legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product description and Part Number (P/N). Sprinkler/Support Cup Assembly Specify: Series LFII Residential Flat- Plate Concealed Pendent Sprinkler (TY2524), K=4.9, without Cover Plate! Retainer Assembly, P/N 51-114-1-160. Cover Plate/Retainer Assembly Specify: Cover Plate/Retainer Assem- bly with finish (below) for the Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524), K=4.9, P/N (below): Chrome .................. P/N 56-201-9-135 Custom ...................P/N 56-201-X-135 Off White ................P/N 56-201-0-135 Pure White (RAL 9010)................P/N 56-201-3-135 Signal White** (RAL 9003) ...............P/N 56-201-4-135 Standard white (Grey White) (RAL9002)................P/N 56-201-5-135 Eastern Hemisphere sales only. Previously known as Bright White. Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions related to custom orders. Sprinkler Wrench Specify W-Type 18 Sprinkler Wrench, P/N 56-000-1-265. STANDARDS COMPLIANCE ASSE® Listed 1013 IAPMO® Listed UL® Classified (less shut-off valves orwith OS&Y valves) C-UL€) Classified CSA® Certified AW/VA Compliant C51i: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDAApproved) Buna Nit,ile (FDAApproved) Polymers Noryl, NSF. Listed Springs Stainless steel, 300 series Relief Valve discharge port: 3/4°-1° - 0.63 sq.in. 1114"-2" - 1.19 sq. in. SHEET APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. FEATURES Sizes: U 3/4" U 1" U 1W 0 1W 02" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI BI.20.1 -. OPTIONS (Suffixes can be combined) U - with fill port QT ball valves (standard) U L - less ball valves U U - with union ball valves U MS - with integral relief valve monitor switch Cl P - for reclaimed water systems 0 S .- with bronze °Y' type strainer U BMS - with battery operated monitor switch U FDC - with fire hydrant connection; 2" only 0 TCU - with test cocks up U V - with union swivel elbows Cl SE - with street elbows U F - with integral male 450 flare SAE test fitting ACCESSORIES U Airgap(ModelAG) 0 Repair kit (rubber only) U Thermal expansion tank (Model WXTP) 0 Soft seated check valve (Model 40) U • Shock arrester (Model 1250) U QT-SET Quick Test Fitting Set U Ball valve handle locks U Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS approximates WEIGHT MODEL A UNION B LESS BALL LESS BALL WITH BALL S A BALL VALVES C 0 E F G VALVES VALVES VALVES in. .!!Em in. nvn In. mm in. mm in. mm In mm in. J -mm In. I mm In. mm lbs lbs. kg 3/4 20 12 305 14 356 73/4 197 21/81 54 3 76 31/2 89 5 1127 153/4 400 10 4.5 12 5.5 1 25 13 330 114 1/4 362 - 7 3/4 197 12 1/81 54 3 76 31/2 89 5 127 17 3/4 451 10 4.5 14 6.4 11/4 32 17 432 19 483 1015/16 278 123141-70 31/2 89 .5 127 63/4 171 22 559 .22. 10 28 12.7 1 142 40 173/8 441120 508 1015/16 278 2 3/4 70 31/2 89 5 127 63/4 171 231/8 587 22 10 28 12.7 2 50 181/2 470121 1/4 50 1015116 278 2314 70 31/2 89 5 127,63/4 171 251/2 648 I 22 10 34 15.41 15 'Ii 10 FLOW CHARACTERISTICS MODEL 975XL 3/4",1",1 1/4", 1 1/2" & 2' (STANDARD & METRIC) FLOW RATES (us) 1.26 2.52 3.8 5.0 3.2 6.3 9.5 12.6 15.8 OL Lu 137 - ________ ..' SOL~A"(50mm) Co 103 9 LLI 10:— ___________ _____ 69 ______________ _____________ U, _____________ Ui 4- 50 100 150 200 250 35 FLOW RATES (GPM) ORated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation re- quirements. To be installed in accor- dance with the manufacturers' instruc- tions and the latest edition of the Uni- form Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above ad- equate drains with sufficient side clear- ance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.. Caoscitv thru Schedule 40 Pioe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec J_15 ft/Sec 1/80 1 1 2 ... 3 1/4° 2 2 3 . 5 3/8" 3 4 6 9 1/2" 5 7 9 14 3/4° 8 12 17 25 1" 13 . 20 27 40 1 1/4" 23 35 47 70 1 1/2 ° 32 48 83 95 2 I 52 78 105 1 167 1 CENTRAL STATION ALARM PANEL BATTERY MONITOR .SWITCH ; AIR 3OMAX. OPTNL AP WATER METER G FLO OR FLOOR ORNN DIRECTION OF FLOW 4) INDOOR INSTALLATION (Shown %doptionall SMS) PROTECTIVE ENCLOSURE I? D IDIRE'I"T-ON 3o AIR GAP DRAIN OFflow INLET SHUT-OFF OUTDOOR INSTALLATION SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180°F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584); the seat ring and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. Page 2of2 . WILKINS a Zuñ, company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga. Ontario L4V 112 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877.222-5356) • Website: http:F/www.zum.com 1 December 20, 2010 Sprinkler 41a MICROFAST® AND N11UNG TECHNI CAL DATA MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking MicrofastO and MicrofastHP' Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflone coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon and Polyester coat- ings as corrosion resistant) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved: Calendar Number 219-76-SA and MEA 8e-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096ef04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1,.EC-certificate of conformity 0832-MED-1003 and 0832-MED-108 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)' Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http:llwww.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A., Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal. K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 'F (-55 'C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY 1s5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 066628 and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, and 067658. Copper UNS- 19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 06720B. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-06000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36009 Form No. F_081296 Replaces page 41a-f, dated November 16, 2010. (Added FM Approval for sprinkler 06765B.) Sprinkler 41b December 20, 2010 ________________________ MicrofastHP0 QUICK r NIMNG4 MI CR0 FA ST5' AND RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings EVIl 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon' Coated Sorinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfaste and MicrofastHPO Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, ChromeEnloye = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflone = N Temperature Suffix (°F/°C): 1350/570 = A, 1550/680 =B, 1750/790 = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK302 with a 1/20 thread, Brass finish and a'155 ¶/68 °C temperature rating = Part No.. 06662BAB Available Finishes And Temperature Ratings: . Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book:) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Coated and/or Recessed Sprinklers: Part No. 12144W/B0 (available since 2003) Optional Protective Sprinkler Cap Remover/Escutcheon Installer. Tool"" Part No. 15915 (available since 2010.) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. "A 1/20 ratchet is required (not available from Viking). ""Allows use from the floor by attaching a length of 10 diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 and MicrofastHPe Quick Response Pendent Sprinklers are available through a network of domestic and international distributors.. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Rats Protective Sprinkler Cap 10896 (D ID: Figure 1: Standard Sprinkler Wrench 10896W/B December 20, 2010 Sprinkler 41c MICROFASTO AND MicrofastHP® QUICK % 1 11(1 I%IGj lI.i[11UI1M RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings NIl 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES At Our NMI RM- "'Wou J11M0HSQ Ordinary 135 'F (57 'C) 100 'F (38 'C) Orange Ordinary 155 'F (68 'C) 100 'F (38 'C) Red Intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow Intermediate .. 200 'F (93 'C) 150 'F (65 'C) Green High 286 'F (141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome-Enloy, White Polyester, Black Polyester, and Black Teflon' Corrosion-Resistant Coatings: White Polyester, Black Polyester, and Black Teflon Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitab'e brine proposco environment. rorauiomauc spriniciers, me coatings inoicaieo are dppIIu w we epueu eIeuvi wuy. Note that the spring is exposed on sprinklers with Polyester and Teflon coatings. WORMENOW reml Sprinkler Wrench I" 7 12144V/BW* for / I installing coated I and/or recessed IN 'pendent sprinklers with protective caps. r ' slide the 4 '' wrench sideways around the protective ---------- cap, ensuring engage- U rierrt with the sprinkler wrench fLats, iEA 1/2' ratchet is required (not available from Viking) Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers 066668 VK352 3/4" 20 m?n 067658 VK352 1/2" 15 mm 06718B9 06720B9 06932B VK329 112" 1.15 mm VK331 1/2" 15 mm VK331. - I 10 mm Sprinkler Thread Size Base SIN Part No' NPT BSP 12282 VK317 1/2" 115 mm ri Sprinkler 41d December 20, 2010 i MICRO FAST® AND MicrofastHP® QUICK. TECHNICAL1 RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings (VII 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Sprinkler I Thread Size Nominal I Overall 1 Listings and Approvals' Base ' SIN I K-Factor Length (Refer also to Design Criteria on page 41e.] Part No.' J NPT I BSP J U.S. J metric2 J Inches J mm J cULus4 NYC' J VdS I LPCB J CE Standard Orifice 06662B I VK302 I -1/2" 115 mm I 5.6 I 80.6 I 2-1/4" I 58 I AIX..BlY I AIX, BIY I A3 A3X. B3Y I C3X.E3Y11 I I I I •. •I I Large Orifice 8.0 115.2 2-3/8" 60 AIX, SlY AIX, B1Y A3 A3X C3" 8.0 115.2 2-3/8" 60 AIX, SlY AiX, SlY A3 - - Small Orifice6 2.8 403 2-3/16" 56 AIX, B1Y AIX, B1Y -- 4.2 57 2-114" 58 AIX, B1Y AIX, B1Y -- - -- 4.2 57 2-3/8" 60 - -- A3 -- G212 Maximum 250 PSI (17 bar) WWP Standard Orifice Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria on page 41e.) U.S. metric2 Inches mm cULus4 NYC1° VdS LPCB 5.6 80.6 2-1/4" 58 AIX, B1Y AIX - - - Maximum 250 PSI (17 bar) WWP Small Orifice9 I I I C3X, E3Y'3 1229010 1 VK342 J 112" 115 mm I 2.8 40.3 2-3/16" J 56 AIX, SlY J AIX -- -- - I - Approved Temperature Ratings A - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), Approved Escutcheons and 286 "F (141 "C) Approved Finishes X - Standard surface-mounted escutcheon or B - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), and 200 "F 1 - Brass, Chrome-EnIoy, White the Viking Microfast Model F-i Adjustable (93 "C) Polyester°7, Black Polyester6.7, Escutcheon C - 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and 286 "F and Black Teflon67 (141 "C) Y - Standard surface-mounted escutcheon or 2 - Brass and Chrome-Enloe the Viking Microfast6 Model F-i Adjustable D - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), and 286 "F (141 °C) 3 - Brass, Chrome-Enloy6, White Escutcheon or recessed with the Viking E - 155 "F (68 "C), 175 "F (79 "C), and 200°F (93 "C) Polyester?. and Black Polyester7 Micromatic6 Model E-i or E-2 Recessed F - 155°F (68 "C), 175°F (79°C), and 286 "F (141 "C) Escutcheon C- 155 "F (68 "C) Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. B Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 6 The sprinkler orifice is bushed. '°Ajepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 11 -t Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. ' ®MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. V_ December 20, 2010 Sprinkler 41 e I . MICROFAST® AND 1111" N V __________________ McrofastHP5 QUICK TECHNICAL - RESPONSE PENDENT SPRINKLERS ............- The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.corn cULus Listing Requirements: MicrofasP and MicrofastHPO Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to -Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to 'page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (58.7 mm) mlrllnUrl I 2-1/8' 2-1/2' (63,5 mm) maximum (54 ) 112, (15 NPT mm) -\__ I ( mom 2-1/4' II LII Ill (445 mm) 1-1/2' (38.1 1-5/8' IJ (41 mm) I I II! (58 mm) (50.8 mm) K Maximum Ii AW Minimum . j . Pendent Sprinkler 06662B (VK302) InstalLed with a standard 1/8' surface- mounted escutcheon. Installed with a Microfast Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon I 2-1/8' Ceiling Opening Size: I 2-1/8' "1 (54 mm) I 2-5/16" (58.7 mm) minimum i (54 mm) 2-1/2" (63.5 rim) maximum 1-1/8' (28.6 mm) Minimum (44.5 mm) Maximum Installed with a Micromatic Model E-1 Recessed Escutcheon 2' tyi 11/8' (28.6 mm) (50.8 mm) Minimum Maximum - Installed with a thread on Model E-2 Recessed Escutcheon 4: Sorinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons Sprinkler .41f December 201 2010 _______________________ MicrofastHP® QUICK 11(1 NG4 MICRO FAST® AND RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com * MiërofastQuick Respons'e PeidenUSrink1ers _ AEW.iIcheDi 3PPIIW$f P PSI (12 Sprinkler Thread Size Nominal K-Factor Overall Lengthj FM Approvals' SIN Base Part No.' (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm Standard Orifice 066628 VK302 112' 15 mm 5.6 80.6 J 2-1/4' J 58 J A2X, B2Y Large Orifice 066668 VK352 3/4" 20 mm 8.0 115.2 2-3/8" f 60 AiX, B1Y 06765B VK352 1/2" 115 mm 8.0 115.2 2-318" 60 AiX, B1Y Small Orifice4 0671886 J VK329 1/2" 15 mm 2.8 40.3 2-3116" 56 AiX Approved Escutcheons Approved Temperature Ratings Approved Finishes X - Standard surface-mounted escutcheon or the Viking A - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 1 - Brass and Chrorne-Enloy' Microfast Model F-i Adjustable Escutcheon 200 "F (93 "C), and 286 "F (141 "C) . 2. Brass, Chrome-Enloy,WutoPotyester, Y - Standard surface-mounted escutcheon or the L3 -135 "F (57 "C), 155 "F (68 "C), 175"F (79 "C), and Black Polyester Viking Microfast Model F-i Adjustable Escutcheon "F and 200 (93.'C) or recessed with the Viking Micromatic Model E-i or E-2 Recessed Escutcheon Footnotes Base part number is shown. For complete pall number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). Other, colors are available on request with the same Listings and Approvals as the standard colors. 6 The sprinkler orifice is bushed. FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceilingslope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria, tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT: Always refer to Bulletin Form No. F,091699 - Care and Handling of Sprinklers. Also refer to page 011I-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated November 16, 2010. (Added FM Approval for sprinkler 06765B.)