HomeMy WebLinkAbout421 TAMARACK AVE; ; AS110139; Permit6/20/24, 8:52 AM AS 110139 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS110139
Job Address: 421 TAMARACK AV
Permit Type: SPRINK
Parcel No: 2060420200
Status: ISSUED
Applied 9/28/2011
Approved: 9/27/2011.
Lot#: .0
Reference No.: Issued: 9/27/2011
PC #: . Inspector:
Project Title: URBINO RESIDENCE SINGLE FAMILY RESIDENCE - ADDITION
OF 7055 S.F. (incl. 2nd FL)
Applicant:
SYMONS FIRE PROTECTION
SUITE
1050 PIONEER WAY
EL CAJON, CA
619-588-6364
Owner:
ALDERSON REVOCABLE TRUST 05-29-02
1122 COUNTRYWOOD LN
VISTA CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
393 . 0 393 0
about:blank Ill
Parsley Consulting
350 West 91 Avenue, Suite 206
E80JiJ0, California 92025-5053
Tc10k0 (760) 745-6181 F(760) 745-0537
September 26, 2011
Fire Code Official
City of Carlsbad Fire Department
Office of Fire Protection Services
1635 Faraday Avenue
Carlsbad, California 92008
Subject: Plan Review for Urbino Residence, 421 Tamarack Avenue, Carlsbad, CA
Dear Sir:
We have reviewed the submittal as prepared by Symons Fire.
Based on our review it is our opinion that the submittal is in substantial conformance with the
applicable codes and standards in force at this time, including local adopted ordinances.
Further submittal should not be required.
Sincerely,
PARSLEY
Renneth W. WagonerT
Office Manager
End (1) Working Drawings - 3 sets
Hydraulic Calculations - 3 sets
Review Comments - I set
Note: A copy of this letter has been transmitted via e-mail to Symons Fire on September 26, 2011
file:\C:\Docurnents and Settings\Ken\Rev2 I 1263.00J.wpd
Urbino Residence Review Comments. Page 2
Review Comments
Urbino Residence, 421 Tamarack Avenue, Carlsbad, CA
1. Field verify that the workshop on the 2 floor is a conditioned space, or the sprinklers in that
space must be intermediate temperature.
The following comments are for your information and will appear on every residential sprinkler review.
The alarm bell must be capable of being heard, above background noise, with doors closed, in all living areas of the
residence. This will be checked at final acceptance.
Pressure required at base of riser will be verified to be available at time of final acceptance.
Sprinkler heads are omitted from bathroom areas under 55 SF in area with noncombustible plumbing fixtures.
Fixtures will be verified at final acceptance.
Sprinkler head blockage or pattern disruption caused by beams or other obstructions will be verified to not exist at
final acceptance inspection.
Sprinkler heads should be located the proper distance from heat sources (stoves, kitchen ranges, fireplaces, heat
diffusers, etc.) This will be checked at final acceptance inspection.
Sprinkler heads located in an unconditioned space (garage, water heater closet, etc.) should be fast response type
with an appropriate temperature rating, commercial heads are acceptable in these areas.
All exposed piping shall be black steel or copper. Concealed piping can be CPVC plastic.
(
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL.
ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. A8 i
LICENSE : 682025 APP SSUBMgTTE DESIGNER : CANDI. CAUDILLO
DATE : 09-14-2011
CARUS RE DEPAR M
FILE : 11-136
JOB NAME : URBINO RESIDENCE 161 FLAT
LOCATION : 421 TAMARACK AVE. CARLSBAD, CA 92008
These II:ins ho'e been re eed lot appaiflt coittphauice
with [tic cuitcnt applicihle codes and standards in louce
in the jurisdictiori. The owner or contract(w may .itilt,c
ktttmon for a huildtn
DESIGN DATA
I hi. re' tew in ¼itppotl ot at app1
pen iii s th the rprcss utder.i;uiU!iflg that this revics
he owner or contractor or their
in to w:u' relics en
engineer or altlIiteet for sole msronihtl1t%
DESIGN CRITERION: N FPA ]_ 3 -
foi lull cutnupIanee with s.tid codes and standards.
lie hI!ultlOt odc Or tOt IUW respollsihiltv tin
juL lu<it't
dcfktCtcIcs. rout s. omissions it neglteiice in these
MIN S PR FLOW 13 Gpm plaii WhitliCI or not noted in ihis review.
;ucff ( Reviewer:
AREA PER SPRINKLER : 256 Sq Ft lEC()MMENDAPPROVAL
TOTAL CALCULATED AREA 512 Sq Ft 0 I:c)NINIEN D APIR(WAI.. AS NOTED
TOTAL SPRINKLERS CALCULATED : 2 Heads
FLOW DATA.
TOTAL SPRINKLER FLOW : 26.1 Gpm
DOMESTIC DEMAND : 5.0 Gpm
TOTAL WATER REQUIRED : 31.1 Gpm
BASE OF RISER NODE: 15 FLOW: 31.1 Gpm PRESSURE: 29.9 Psi
AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DEPARTMENT
PHONE : (760) 602-4666
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31
- SUBMITTAL. I
'ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364.
ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020.
Date: 09-14-2011 File: C:\RESDEN43\11-136.RES JOB : URBINO RESIDENCE 16'FLAT
Page 1
SOURCE I STATIC : 85.0 Psi RESIDUAL : 84.0.Psi. FLOW : 31 Gpm
DESIGN I SPRINKLER MANUF : TYCO MODEL : LFII I SPRINKLER Q : .0 Gpm VALVE : 12.0 Psi
- I SPRINKLER P : .0 Psi METER : 4.0 Psi
NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm
1 28.0 4.9 7.0 13.0 2 28.0 4.9 7.2 13.1 3 28.0 7.6 4 25.0 11.8 5 25.0 10.7 6 25.0 12.3 7 28.0 11.7 8 28.0 10.8 9 28.0 11.9 10 15.0 18.4 11 15.0 20.4 12 15.0 19.8 13 15.0 21.7 14 15.0 24.3 15 9.0 29.9 5.0 DOME 16 5.0 34.9 17 3.0 37.5 18 3.0 49.5 19 3.0 50.2 20 .0 SOURCE 61.6 31.1
SPRINKLERS FLOWING : 2
AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 512 Sq Ft
REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .051 Gpm/Sq Ft
TOTAL SPRINKLER FLOW : 26.1 Gpm TOTAL DOMESTIC FLOW : 5 Gpm
TOTAL WATER REQUIRED : 31.1 Gpm
TOTAL SPRINKLER PRESS : 45.6 Psi WATER METER LOSS : 4.0 Psi VALVE FIXED LOSS : 12.0 Psi
Copyright (2002) SUPPLY PRESS AVAILABLE : 84.0 Psi by DEMAND PRESS REQUIRED : 61.6 Psi Hydronics Engineering PRESSURE CUSHION 22.4 Psi 34119 Fremont Bi, Suite 609
Fremont, Ca., 94555
MAXIMUM
HYDRDNICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2
ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364.
ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020.
Date: 09-14-2011 File: C:\RESDEN43\11-136.RES
JOB : URBINO RESIDENCE 16'FLAT
PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE
NO. Gpm FITTING TYPE FTG FR- LOSS Psi
END DIAMETER TOTAL (Psi/Ft)
- 1 q= 13.0 K= 4.9 L= 7.0 Pt 7.0 Pt 7.0
1 Q= 13.0 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1
Ve1= 4.4 D= 1.101 TL= 19.0 .0305 Pf .6 Pn 6.9
3 Pt 7.6
2 q= 13.1 K= 4.9
--------------------------------------------------------------------------
L= 2.0 Pt 7.2 Pt 7.2
2 Q= 13.1 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1
Ve1= 4.4 D= 1.101 TL= 14.0 .0311 Pf .4 Pn 7.0
3 Pt 7.6
3 q= .0 K= .0
--------------------------------------------------------------------------
L= 22.0 Pt 7.6 Pt 7.6
3 Q= 17.7 F= 2B3L F= 31.0 C= 150 Pe 1.3 Pv -.2
Ve1= 6.0 D= 1.101 TL= 53.0 .0542 Pf 2.9 Pn 7.4
4 Pt 11.8
3 q= .0 K= .0
--------------------------------------------------------------------------
L= 70.0 Pt 7.6 Pt 7.6
4 Q= 8.4 F= 5R3B2E6L
64.0 C= 150 Pe 1.3 Pv -.1
Ve1= 2.8 D= 1.101 TL= 134.0 .0137 Pf 1.8 Pn 7.5
5 Pt 10.7
- 5 q= .0 K= .0 L= 49.0 Pt 10.7 Pt 10.7
5 Q= 8.4 F= 2R2B6L F= 54.0 C= 150 Pe -1.3 Pv -.1
Ve1= 2.8 D= 1.101 TL= 103.0 .0137 Pf 1.4 Pn 10.7
8 Pt 10.8
8 q= .0 K= .0
--------------------------------------------------------------------------
L= 51.0 Pt 10.8 Pt 10.8
6 Q= 8.4 F= 2R2B2E2L
F= 28.0 C= 150 Pe .0 Pv -.1
Ve1= 2.8 D= 1.101 TL= 79.0 .0137 Pf 1.1 Pn 10.8
9 Pt 11.9
4 q= .0 K= .0
--------------------------------------------------------------------------
L= 64.0 Pt 11.8 Pt 11.8
7 Q= 5.5 F= 6R2B F= 16.0 C= 150 Pe .0 Pv .0
Ve1= 1.9 D= 1.101 TL= 80.0 .0062 Pf .5 Pn 11.8
6 Pt 12.3
6 q= .0 K= .0
--------------------------------------------------------------------------
L= 64.0 Pt 12.3 Pt 12.3
8 Q= 5.5 F= 4R6L2B F= 56.0 C= 150 Pe -1.3 Pv .0
Ve1= 1.9 D= 1.101 TL= 120.0 .0062 Pf .7 Pn 12.3
H 7 Pt 11.7
7 q= .0 K= .0
--------------------------------------------------------------------------
L= 21.0 Pt 11.7 Pt 11.7
9 Q= 5.5 F= 1R2B F= 11.0 C= 150 Pe .0 Pv .0
Ve1= 1.9 D= 1.101 TL= 32.0 .0062 Pf .2 Pn 11.7
9 Pt 11.9
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3
ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364.
ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020.
Date: 09-14-2011 File: C::\RESDEN43\11136.RES
JOB : URBINO RESIDENCE 16!FLAT
PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE
NO. Gpm FITTING TYPE FTG FR- LOSS Psi
END DIAJ4ETER . TOTAL (Psi/Ft)
4 q= .0 K= .0 L= 54.0 Pt 11.8 Pt 11.8
10 Q= 12.2 F= 2R2L3B F= 31.0 C= 150 Pe 4.3 Pv -.1
Vel= 4.1 D= 1.101 TL= 85.0 .0272 Pf 2.3 Pn 11.7
10 Pt 18.4
9 q= .0 K= .0
--------------------------------------------------------------------------
L= 31.0 Pt 11.9 Pt 11.9
11 Q= 13.9 F= 1R3L2B F= 32.0 C= 150 Pe 5.6 Pv -.1
Vel= 4.7 D= 1.101 TL= 63.0 .0347 Pf 2.2 Pn 11.8
12 Pt 19.8
10 q= .0 K= .0
--------------------------------------------------------------------------
L= 52.0 Pt 18.4 Pt 18.4
12 Q= 12.2 F= 4R33 F= 19.0 C= 150 Pe .0 Pv -.1
Vel= 4.1 D= 1.101 TL= 71.0 .0272 Pf 1.9 Pn 18.3
11 Pt 20.4
11 q= .0 K= ..0
--------------------------------------------------------------------------
L= 34.0 Pt 20.4 Pt 20.4
13 Q= 12.2 F= 4R2B F= 14.0 C= 150 Pe .0 Pv -.1
Vel= 4.1 D= 1.101 TL= 48.0 .0272 Pf 1.3 Pn 20.3
13 Pt 21.7
12 q= .0 K= .0
--------------------------------------------------------------------------
L= 36.0 Pt 19.8 Pt 19.8
14 Q= 13.9 F= 2R1L2B F= 19.0 C= 150 Pe .0 Pv -.1
Vel= 4.7 D= 1.101 TL= 55.0 .0347 Pf 1.9 Pn 19.6
13 Pt 21.7
13 q= .0 K= .0
--------------------------------------------------------------------------
L= 10.0 Pt 21.7 Pt 21.7
15 Q= 26.1 F= 1R1B1L F= 13.0 C= 150 Pe .0 Pv -.5
Vel= 8.8 D= 1.101 TL= 23.0 .1112 Pf 2.6 Pn 21.2
14 Pt 24.3
14 q= .0 K= .0
--------------------------------------------------------------------------
L= 6.0 Pt 24.3 Pt 24.3
16 Q= 26.1 F= 1C4R1S1L
F= 21.0 C= 150 Pe 2.6 Pv -.5
Vel= 8.8 D= 1.101 TL= 27.0 .1112 Pf 3.0 Pn 23.7
15 1Pt 29.9
15 q= 5.0 DOME
--------------------------------------------------------------------------
L= 5.0 Pt 29.9 Pt 29.9
17 Q= 31.1 F= 1G2L1B F= 10.0 C= 150 Pe 1.7 Pv -1.0
Vel= 12.1 D= 1.025 TL= 15.0 .2179 Pf 3.3 Pn 28.9
16 Pt 34.9
16 q= .0 K= .0
--------------------------------------------------------------------------
L= 200.0 Pt 34.9 Pt 34.9
18 Q= 31.1 F= 10C F= 10.0 C= 150 Pe .9 Pv -.1
Vel= 3.2 D= 2.003 TL= 210.0 .0083 Pf 1.8 Pn 34.8
17 Pt 37.5
17 Q= 31.1
--------------------------------------------------------------------------
Pt 37.5
BFP FIXED PRESSURE LOSS Valve 12.0
18 Pt 49.5
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 4
ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364.
ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020.
Date: 09-14-2011 File: C:\RESDEN43\11-136.RES
JOB : URBINO RESIDENCE 161 FLAT
PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE
NO. Gpm FITTING TYPE FTG FR- LOSS Psi
END DIAMETER TOTAL (Psi/Ft)
---------------------------------------------------------------------------
18 q= .0 K= .0 L= 2.0 Pt 49.5 Pt 49.5
20 Q= 31.1 F= 1C F= 1.0 C= 150 Pe .0 Pv -1.0
Vel= 12.1 D= 1.025TL= 3.0 .2179 Pf .7 Pn 48.5
19 Pt 50.2 --------------------------------------------------------------------------
19 q= .0 K= .0 L= 20.0 Pt 50.2 Pt 50.2
21 Q= 31.1 F= 2C F= 4.0 C= 150 Pe 1.3 Pv -1.1
Vel= 12.8 D= .995 TL= 24.0 .2518 Pf 6.0 Pn 49.1
20 Pt 57.6 --------------------------------------------------------------------------
Meter = 4.0 --------------------------------------------------------------------------
Q= 31.1 <<< SOURCE >>> Pt 61.6 --------------------------------------------------------------------------
E=>45-Elb L=>90-E1b B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL.
ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364.
ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020.
DATE : 09-14-2011 FILE : C:\RESDEN43\11-136.RES
JOB : URBINO RESIDENCE 161 FLAT
PSI FIRE SPRINKLER HYDRAULIC GRAPH
100
90
80
70
60 — 'ft
50 -
30
20
10
10 15 20 25
0 Supply Curve
Static : 85.0
Resid : 84.0
Flow : 31.0
30 35 40 45 50
FLOW - Gpm
Demand Curve
Avi Pr : 84.0 @ 31
Req. Pr : 61.6 @ 31
Pr Cush: 22.4
Copyright: Hydronics Engineering, 2002.
34119 Fremont Bi, Suite 609,
Fremont, CA. 94555.
(510) 487-9160.
Lb
tqCa Rre Suppression I & Building Products I
Irapid responses
Technical Services 800-381-9312 +1-401-781-8220 HOME FIRE SPRINKLER SYSTEM
www.tyco-fire.com I
Series LFII Residential Sprinklers
Flat-Plate Concealed Pendent
49 K-Factor
General
Description
The TYCO RAPID RESPONSE Series
LFII Residential Flat-Plate Concealed
Pendent Sprinklers (TY2524) are decora-
tive, fast response, fusible solder sprin-
klers designed for use in residential oc-
cupancies such as homes, apartments,
dormitories, and hotels.
The Cover Plate/Retainer Assembly con-
ceals the sprinkler operating compo-
nents above the ceiling. The flat profile
of the Cover Plate provides the optimum
aesthetically appealing sprinkler design.
Additionally, the concealed design of the
Series LFII Residential Flat-Plate Con-
cealed Pendent Sprinklers provides 1/2
inch (12;8 mm) vertical adjustment. This
adjustment provides a measure of flex-
ibility when cutting fixed pipe drops.
The Series LFII Residential Flat-Plate
Concealed Pendent Sprinklers are in-
tended for use in the following systems:
per NFPA 13D, wet pipe residential
sprinkler systems for one- and two-
family dwellings and mobile homes;
per NFPA 13R, wet pipe residential
sprinkler systems for residential oc-
cupancies up to and including four
stories in height; and
per NFPA 13, wet pipe sprinkler sys-
tems for the residential portions of
any occupancy.
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and in-
stallation can permanently damage
a sprinkler system or its components
and cause the sprinkler to fall to
operate in a fire situation or cause it
to operate prematurely.
The Series LFII Residential Flat-Plate
Concealed Pendent Sprinkler has a 4.9
(60,5) K-factor that provides the required
residential flow rates at reduced pres-
sures, enabling smaller pipe sizes and
water supply requirements.
This sprinkler has been designed with
heat sensitivity and water distribution
characteristics proven to help in the con-
trol of residential fires and to improve
the chance for occupants to escape or
be evacuated.
The Series LFII Residential Flat-Plate
Concealed Pendent Sprinklers are
shipped with a Disposable Protective
Cap. The Protective Cap protects the
sprinkler during ceiling installation or
finish. After ceiling installation is com-
plete, the Protective Cap is removed
and the Cover Plate/Retainer Assem-
bly is installed. Removing the Protec-
tive Cap is required for proper sprinkler
performance.
Ii'L.Jt(.1
The Series LFII Residential Rat-Plate
Concealed Pendent Sprinklers (TY2524)
described herein must be installed and
maintained in compliance with this doc-
ument and with the applicable standards
of the National Fire Protection Associa-
tion, in addition to the standards of any
authorities having jurisdiction. Failure
to do so may impair the performance
of these devices.
Owners are responsible for maintaining
their fire protection system and devices
in proper operating condition. The in-
stalling contractor or sprinkler manu-
facturer should be contacted with any
questions.
Model/Sprinkler
Identification
Number (SIN)
TY2524
Technical
Data
Approvals
UL and C-UL Listed
NSF-61 Certified
The Series LFII Residential Flat-Plate
Concealed Pendent Sprinklers are only
listed with the Series LFII Concealed
Cover Plates having a factory-applied
finish.
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K=4.9 GPM/psi"2 (70,6 LPM/bar
Temperature Rating
Sprinkler: 160°F (71°C)
Cover Plate: 139°F (59°C)
Vertical Adjustment
112 inch (12,7 mm)
Finishes
Refer to the Ordering Procedure
section.
Physical Characteristics
Cover Plate/Retainer Assembly:
Cover Plate .............Copper
Ejection Spring .... Stainless Steel
Retainer ................Brass
Page 1 of 6 OCTOBER 2010 TFP443
TFP443
Page 2 of 6
Horizontal Ceiling. Sloped Ceiling Sloped Ceiling
Minimum Flowib) and Minimum Flow' and Minimum Flowla) and
Residual Pressure Residual Pressure Residual Pressure
Maximum Maximum (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise Coverage Spacing for 12-inch run) up to maximum 4-inch up to maximum 8-inch Area a) rise for 12-inch run) rise for 12-inch run)
160°F (71°C) 160°F (71°C) 160°F (71°C)
Sprinkler Sprinkler Sprinkler
12'x 12 12 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM)
(3,7 in x 3,7 m) (3,7 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0.83 bar)
14'x 14' 14' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (4,3 in 4,3 m) (4,3 m) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar)
16' x 16' 16' 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 17 GPM (64.3 LPM) (4,9 m x 4,9 m) (4,9 m). 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar)
18' x 18' 18' 17 GPM (64,3 LPM) 22 GPM (83,3 LPM) 22 GPM (83,3 LPM) (5,5 m x 5,5 m) (5,5 ni) 12.0 psi (0,83 bar) 20.2 psi (1,39 bar) 20.2 psi (1,39 bar)
20'x 20' 20' 20 GPM (75,7 LPM) 24 GPM (90,8 LPM) 24 GPM (90,8 LPM)
(6,1 m x 6,1 m) (6,1 m) 16.7 psi (1,15 bar) 24.0 psi (1,65 bar) 24.0 psi (1,65 bar)
For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage
area for which Hydraulic Design section under the Design Criteria are stated.
The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures
are calculated using the nominal K-factor. Refer to "Hydraulic Design' in the Design Criteria section for details.
TABLEA
SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524)
NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA
WET PIPE SYSTEMS
Sprinkler/Support Cup Assembly:
Body ...................Brass
Cap ...................Bronze
Saddle ..................Brass
Sealing, Assembly .......Beryllium
Nickel w/ Teflon'
Soldered Link Halves ......Nickel
Lever ..................Bronze
Compression Screw .......Brass
Deflector ................Bronze
Guide Pin Housing........Bronze
Guide Pins .............Bronze
Support Cup ..............Steel
Operation
When exposed to heat from a fire, the
Cover Plate, which is normally soldered
to the Retainer at three points, falls away
to expose the Sprinkler/Support Cup As-
sembly. At this point, the Deflector, sup-
ported by the Guide Pins, drops down
to its operated position.
The Solder Link Element of the Sprinkler/
Support Cup Assembly is comprised of
two link halves that are soldered togeth-
er with a thin layer of solder. When the
rated temperature is reached, the sol-
der melts and the two link halves sepa-
rate, allowing the sprinkler to activate
and flow water.
1 Registered trademark of Dupont
Design
Criteria
The TYCO RAPID RESPONSE Series
LFII Residential Flat-Plate Concealed
Pendent Sprinklers (TY2524) are UL
and C-UL Listed for installation in ac-
cordance with the following criteria.
L't.1t(.1
When conditions exist that are outside
the scope of the provided criteria, re-
fer to the Residential Sprinkler Design
Guide TFP490 for the manufacturer's
recommendations that maybe accept-
able to the Authority Having Jurisdiction.
The Series LFII Residential Flat-Plate
Concealed Pendent Sprinklers must
not be used in applications where the
air pressure above the ceiling is greater
than that below. Down drafts through
the Support Cup can delay sprinkler op-
eration in a fire situation.
System Type
Only wet pipe systems may be utilized.
Hydraulic Design
Table A provides the minimum required
sprinkler flow rate for systems designed
to NFPA 13D or NFPA 13R as a function
of temperature rating and the maximum
allowable coverage areas. The sprinkler
flow rate is the minimum required dis-
charge from each of the total number of
"design sprinklers" as specified in NFPA
130 or NFPA 13R.
For systems designed to NFPA 13, the
number of design sprinklers is to be
the .four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
is to be the greater of the following:
flow rates given in Table A for NFPA
13D and 13R as a function of tem-
perature rating and the maximum al-
lowable coverage area
minimum discharge of 0.1 GPM/
sq. ft. over the "design area" com-
prised of the four most hydraulically
demanding sprinklers for actual cov-
erage areas protected by the four
sprinklers
Obstruction To Water Distribution
Locate sprinklers in accordance with the
obstruction rules of NFPA for residential
sprinklers as well as obstruction criteria
described within TYCO technical data
sheet TFP490.
Operational Sensitivity
Install sprinklers relative to the ceiling
mounting surface as shown in Figure 3.
Sprinkler Spacing
The minimum spacing between sprin-
klers is 8 feet (2,4 m).
The maximum spacing between sprin-
klers cannot exceed the length of the
coverage area (Table A) being hydrau-
lically calculated; for example, a maxi-
mum of 12 feet for al2 ft. x 12 ft. cov-
erage area or 20 feet for a 20 ft. x 20 ft.
coverage area.
SPRINKLER-
LJPPORT CUP
SEMBLY
OPERATE
SPRINKLE
COVER
PLATE
RETAINE
7/8" (22,2 n
1-1/8" (28,6
WRENCH
RECESS
.ef
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 2
W-TYPE 18
SPRINKLER WRENCH
DEFLECTOR IN
OPERATED POSITION
TFP443
Page 3 of 6
BODY SEALING (1/2"NP1) ASSEMBLY
CAP
SPRINKLER
WRENCHING
AREA SADDLE
51wP0m h COMPRESSION
CUP WITH SCREW
ROLL FORMED
THREADS
LEVER
GUIDE
PIN
SOLDER LINK / ELEMENT
GUIDE PIN
HOUSING
DEFLECTOR
/ I
r__ DEFLECTOR
'-'
POSITION)
SPRINKLER/SUPPORT CUP
ASSEMBLY
THREAD-INTO RETAINER SUPPORT CUP H WITH THREAD UNTIL MOUNTING H - DIMPLES SURFACE IS r
FLUSH WITH J EJECTION CEILING SPRING
SOWER' COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE
FIGURE 1
FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524)
ASSEMBLY
2-1/2" DIA.
mm) FACE OF
1/2"THREADED SPRINKLER
NPT ADJUSTMENT
-
FilliNG
I
J
k
L 635mrn 1I2(,27
-
L (47,6 mm
1/8 GAP I 3,2 mm)
(3,(3,2 mm)
I COVER- SPRINKLER- J MOUNTING RETAINER SUPPORT CUP ' SURFACE ASSEMBLY ASSEMBLY (48 mm)
- 3-3/16" DIA. / DISPOSABLE (81,0 mm) TIP PROTECTIVE CAP
FIGURE 3
PROTECTIVE CAP AND ACTIVATED DEFLECTOR
INSTALLATION DIMENSIONS
TFP443
Page 4 of 6
Installation
The TYCO RAPID RESPONSE Series
LFII Residential Flat-Plate Concealed
Pendent Sprinklers must be installed
in accordance with the following
instructions.
NOTICE
Damage to the Solder Link Element dur-
ing installation can be avoided by han-
dling the sprinkler by the Support Cup
only; that is, do not apply pressure to the
Solder Link Element (Figure 1).
Obtain a leak-tight 1/2 inch NPT sprinkler
joint by applying a minimum-to-maxi-
mum torque of 7 to 14 ft.-lbs. (,5 to 19,0
Nm). Higher levels of torque can distort
the sprinkler inlet with consequent leak-
age or impairment of the sprinkler.
Do not attempt to compensate for in-
sufficient adjustment in the Cover Plate!
Retainer Assembly by under- or over-
tightening the sprinkler Re-adjust the
position of the sprinkler fitting to suit.
Install pendent sprinklers in the
pendent position, with the center-
line of the sprinkler perpendicular
to the mounting surface.
Remove the Protective Cap.
With pipe-thread sealant applied
to the pipe threads,. and using the
W-Type 18 Wrench shown in Figure
2, install and tighten the Sprinkler!
Support Cup Assembly into the fit-
ting. The W-Type 18 Wrench ac-
cepts a 1/2 inch ratchet drive.
Replace .the —Protective —Cap by
pushing it upwards until it bottoms
out against the Support Cup. The
Protective Cap helps prevent dam-
age to the Deflector and Guide
Pins during ceiling installation and/
or during application of the finish
coating of the ceiling.
As long as the protective Cap re-
mains in place, the system is con-
sidered "Out Of Service".
After the ceiling has been• com-
pleted with the 2-1/2 inch (63 mm)
diameter clearance hole and in
preparation for installing the Cover
Plate/Retainer Assembly, remove
and discard the Protective Cap,
and verify that the Deflector moves
up and down freely.
If the Sprinkler has been damaged
and the Deflector does not move up
and down freely, replace the entire
Sprinkler assembly. Do not attempt to
modify or repair a damaged sprinkler.
Screw on the Cover Plate/Retainer
Assembly until its flange contacts
the ceiling.
Do notcontinue to screw on the
Cover Plate/Retainer Assembly such
that it lifts a ceiling panel out of its
normal position.
If the Cover Plate/Retainer Assembly
cannot be engaged with the Mounting
Cup or the Cover Plate/Retainer As-
sembly cannot be engaged sufficiently
to contact the ceiling, the Sprinkler
Fitting must be repositioned.
Care and
Maintenance
The TYCO RAPID RESPONSE Series
LFII Residential Flat-Plate Concealed
Pendent Sprinkler (TY2524) must be
maintained and serviced in accordance
with the following instructions.
Replace sprinklers that:
were damaged by dropping, striking,
wrench twisting, wrench slippage, or
the like.
were modified or over-heated.
are leaking or exhibiting visible signs
of corrosion.
Responsibility lies with owners for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards of
the National Fire Protection Association
(for example, NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or sprinkler manufacturer
regarding any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
Before closing a fire protection system
main control valve for maintenance work
on the fire protection system that it con-
trols, obtain permission to shut down the
affected fire protection system from the
proper authorities and notify all person-
nel who maybe affected by this action.
When properly installed, there is a nomi-
nal 1/8 inch (3,2 mm) air gap between
the lip of the Cover Plate and the ceil-
ing, as shown in Figure 3. This air gap
is necessary for proper operation of the
sprinkler by allowing heat flow from a
fire to pass below and above the Cover —Plate-to helpassure appropriate release
of the Cover Plate in a fire situation. If the
ceiling needs repainting after sprinkler
installation, exercise care to ensure that
the new paint does NOT seal off any of
the air gap. Failure to do so may impair
sprinkler operation.
Absence of a Cover Plate can delay the
sprinkler operation in a fire situation.
Do not pull the Cover Plate relative to
the Enclosure. Separation may result.
Exercise care to avoid damage to sprin-
klers before, during, and after installa-
tion. Never paint, plate, coat, or other-
wise after automatic sprinklers after they
leave the factory.
Never repaint factory-painted Cover
Plates. When necessary, replace cover
plates with factory-painted units. Non-
factory applied paint can adversely de-
lay or prevent sprinkler operation in the
event of a fire.
TFP443
Page 5 of 6
Limited
Warranty
Products manufactured by Tyco Fire
Suppression & Building Products
(TFSBP) are warranted solely to the orig-
inal Buyer for ten (10) years against de-
fects in material and workmanship when
paid for and properly installed and main-
tained under normal use and service.
This warranty will expire ten (10) years
from date of shipment by TFSBP. No
warranty is given for products or com-
ponents manufactured by companies
not affiliated by ownership with TFSBP
or for products and components which
have been subject to misuse, improper
installation, corrosion, or which have not
been installed, maintained, modified or
repaired in accordance with applicable
Standards of the National Fire Protection
Association, and/or the standards of any
other Authorities Having Jurisdiction.
Materials found by TFSBP to be defec-
tive shall be either repaired or replaced,
at TFSBP's sole option. TFSBP neither
assumes, nor authorizes any person to
assume for it, any other obligation in
connection witb the sale of products or
parts of products. TFSBP shall not be
responsible for sprinkler system design
errors or inaccurate or incomplete in-
formation supplied by Buyer or Buyer's
representatives.
In no event shall TFSBP be liable, in con-
tract, tort, strict liability or under any oth-
er legal theory, for incidental, indirect,
special or consequential damages, in-
cluding but not limited to labor charg-
es, regardless of whether TFSBP was
informed about the possibility of such
damages, and in no event shall TFSBP's
liability exceed an amount equal to the
sales price.
The foregoing warranty is made in lieu
of any and all other warranties, express
or imglied.. including warranties of mer-
chantability and fitness for a particular
ouroose.
This limited warranty sets forth the ex-
clusive remedy for claims based on fail-
ure of or defect in products, materials or
components, whether the claim is made
in contract, tort, strict liability or any oth-
er legal theory.
This warranty will apply to the full extent
permitted by law. The invalidity, in whole
or part, of any portion of this warranty
will not affect the remainder.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product description and Part
Number (P/N).
Sprinkler/Support Cup Assembly
Specify: Series LFII Residential Flat-
Plate Concealed Pendent Sprinkler
(TY2524), K=4.9, without Cover Plate!
Retainer Assembly, P/N 51-114-1-160.
Cover Plate/Retainer Assembly
Specify: Cover Plate/Retainer Assem-
bly with finish (below) for the Series
LFII Residential Flat-Plate Concealed
Pendent Sprinkler (TY2524), K=4.9, P/N
(below):
Chrome .................. P/N 56-201-9-135
Custom ...................P/N 56-201-X-135
Off White ................P/N 56-201-0-135
Pure White
(RAL 9010)................P/N 56-201-3-135
Signal White**
(RAL 9003) ...............P/N 56-201-4-135
Standard white (Grey White)
(RAL9002)................P/N 56-201-5-135
Eastern Hemisphere sales only.
Previously known as Bright White.
Note: All Custom Cover Plates are
painted using Sherwin Williams Interior
Latex Paint. Contact TYCO Customer
Service with any questions related to
custom orders.
Sprinkler Wrench
Specify W-Type 18 Sprinkler Wrench,
P/N 56-000-1-265.
STANDARDS COMPLIANCE
ASSE® Listed 1013
IAPMO® Listed
UL® Classified (less shut-off valves orwith OS&Y valves)
C-UL€) Classified
CSA® Certified
AW/VA Compliant C51i:
Approved by the Foundation for Cross Connection
Control and Hydraulic Research at the University of
Southern California
MATERIALS
Main valve body Cast Bronze ASTM B 584
Access covers Cast Bronze ASTM B 584
Fasteners Stainless Steel, 300 Series
Elastomers Silicone (FDAApproved)
Buna Nit,ile (FDAApproved)
Polymers Noryl, NSF. Listed
Springs Stainless steel, 300 series
Relief Valve discharge port:
3/4°-1° - 0.63 sq.in.
1114"-2" - 1.19 sq. in.
SHEET
APPLICATION
Designed for installation on potable water lines to protect
against both backsiphonage and backpressure of contami-
nated water into the potable water supply. Assembly shall
provide protection where a potential health hazard exists.
FEATURES
Sizes: U 3/4" U 1" U 1W 0 1W 02"
Maximum working water pressure 175 PSI
Maximum working water temperature 180°F
Hydrostatic test pressure 350 PSI
End connections Threaded ANSI BI.20.1
-. OPTIONS
(Suffixes can be combined)
U - with fill port QT ball valves (standard)
U L - less ball valves
U U - with union ball valves
U MS - with integral relief valve monitor switch
Cl P - for reclaimed water systems
0 S .- with bronze °Y' type strainer
U BMS - with battery operated monitor switch
U FDC - with fire hydrant connection; 2" only
0 TCU - with test cocks up
U V - with union swivel elbows
Cl SE - with street elbows
U F - with integral male 450 flare SAE test fitting
ACCESSORIES
U Airgap(ModelAG)
0 Repair kit (rubber only)
U Thermal expansion tank (Model WXTP)
0 Soft seated check valve (Model 40)
U • Shock arrester (Model 1250)
U QT-SET Quick Test Fitting Set
U Ball valve handle locks
U Test Cock Lock (Model TCL24)
DIMENSIONS & WEIGHTS (do not include pkg.)
DIMENSIONS approximates WEIGHT MODEL A UNION B LESS BALL LESS BALL WITH BALL S A BALL VALVES C 0 E F G VALVES VALVES VALVES
in. .!!Em in. nvn In. mm in. mm in. mm In mm in. J -mm In. I mm In. mm lbs lbs. kg 3/4 20 12 305 14 356 73/4 197 21/81 54 3 76 31/2 89 5 1127 153/4 400 10 4.5 12 5.5
1 25 13 330 114 1/4 362 - 7 3/4 197 12 1/81 54 3 76 31/2 89 5 127 17 3/4 451 10 4.5 14 6.4 11/4 32 17 432 19 483 1015/16 278 123141-70 31/2 89 .5 127 63/4 171 22 559 .22. 10 28 12.7 1 142 40 173/8 441120 508 1015/16 278 2 3/4 70 31/2 89 5 127 63/4 171 231/8 587 22 10 28 12.7
2 50 181/2 470121 1/4 50 1015116 278 2314 70 31/2 89 5 127,63/4 171 251/2 648 I 22 10 34 15.41
15
'Ii
10
FLOW CHARACTERISTICS
MODEL 975XL 3/4",1",1 1/4", 1 1/2" & 2' (STANDARD & METRIC)
FLOW RATES (us)
1.26 2.52 3.8 5.0 3.2 6.3 9.5 12.6 15.8 OL Lu 137 - ________ ..'
SOL~A"(50mm) Co
103 9 LLI 10:—
___________ _____
69
______________
_____________ U, _____________ Ui
4- 50 100 150 200 250
35
FLOW RATES (GPM)
ORated Flow (Established by approval agencies)
TYPICAL INSTALLATION
Local codes shall govern installation re-
quirements. To be installed in accor-
dance with the manufacturers' instruc-
tions and the latest edition of the Uni-
form Plumbing Code. Unless otherwise
specified, the assembly shall be mounted
at a minimum of 12" (305mm) and a
maximum of 30" (762mm) above ad-
equate drains with sufficient side clear-
ance for testing and maintenance. The
installation shall be made so that no part
of the unit can be submerged..
Caoscitv thru Schedule 40 Pioe
Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec J_15 ft/Sec 1/80 1 1 2 ... 3 1/4° 2 2 3 . 5 3/8" 3 4 6 9 1/2" 5 7 9 14
3/4° 8 12 17 25 1" 13 . 20 27 40
1 1/4" 23 35 47 70 1 1/2 ° 32 48 83 95 2 I 52 78 105 1 167 1
CENTRAL
STATION
ALARM
PANEL
BATTERY
MONITOR .SWITCH
;
AIR
3OMAX.
OPTNL AP
WATER METER G
FLO
OR
FLOOR ORNN
DIRECTION OF FLOW 4)
INDOOR INSTALLATION
(Shown %doptionall SMS)
PROTECTIVE
ENCLOSURE
I?
D IDIRE'I"T-ON
3o
AIR GAP
DRAIN
OFflow
INLET SHUT-OFF
OUTDOOR INSTALLATION
SPECIFICATIONS
The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180°F and supplied with
full port ball valves. The main body and access covers shall be bronze (ASTM B 584); the seat ring and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks
shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed
indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure
Principle Backflow Preventer shall be a WILKINS Model 975XL.
Page 2of2 .
WILKINS a Zuñ, company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga. Ontario L4V 112 Phone:905/405-8272 Fax:905/405-1292
Product Support Help Line: 1-877-BACKFLOW (1-877.222-5356) • Website: http:F/www.zum.com
1
December 20, 2010 Sprinkler 41a
MICROFAST® AND N11UNG TECHNI CAL DATA MicrofastHP® QUICK
RESPONSE PENDENT
SPRINKLERS
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com
DESCRIPTION
Viking MicrofastO and MicrofastHP' Quick Response Pendent Sprinklers are small,
thermosensitive, glass-bulb spray sprinklers available in several different finishes and
temperature ratings and K-Factors to meet design requirements. The special Polyester
and Teflone coatings can be used in decorative applications where colors are desired.
In addition, these coatings have been investigated for installation in corrosive at-
mospheres and are cULus listed as corrosion resistant as indicated in the Approval
Chart. (Note: FM Global has no approval classification for Teflon and Polyester coat-
ings as corrosion resistant)
LISTINGS AND APPROVALS
cULus Listed: Category VNIV
FM Approved: Classes 2001, 2002, 2015, and 2017
NYC Approved: Calendar Number 219-76-SA and MEA 8e-92-E, Volume 16
ABS Certified: Certificate 04-HS407984C-PDA
VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021
LPC Approved: Ref. Nos. 096e/03 and 096ef04
CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and
0786-CPD-40170
MED Certified: Standard EN 12259-1,.EC-certificate of conformity 0832-MED-1003 and 0832-MED-108
NOTE: Other International approval certificates are available upon request.
Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design
Criteria on page 41f for FM Approval requirements that must be followed.
TECHNICAL DATA
Specifications:
Available since 1987.
Minimum Operating Pressure: 7 psi (0.5 bar)'
Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on
use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at
(0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- http:llwww.vikinggroupinc.com.
sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent
the deflector. All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page.
maximum 175 psi (12 bar) wwp.
Factory tested hydrostatically to 500 psi (34.5 bar)
Testing: U.S.A., Patent No. 4,831,870
Thread size: Refer to the Approval Charts
Nominal. K-Factor: Refer to the Approval Charts
Glass-bulb fluid temperature rated to -65 'F (-55 'C)
Overall Length: Refer to the Approval Charts
*cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE
Approvals ONLY 1s5 psi (0.35 bar).
Material Standards:
Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 066628 and 12282. Brass UNS-C84400 for all other sprinklers.
Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, and 067658. Copper UNS-
19500 for Sprinkler 12282. Phosphor Bronze UNS-051000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler
06720B. Brass UNS-C26000 for all other Sprinklers.
Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-06000
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape
Screw: Brass UNS-C36009
Form No. F_081296 Replaces page 41a-f, dated November 16, 2010.
(Added FM Approval for sprinkler 06765B.)
Sprinkler 41b December 20, 2010
________________________ MicrofastHP0 QUICK
r
NIMNG4
MI CR0 FA ST5' AND
RESPONSE PENDENT
SPRINKLERS
The Viking Corporation, 210 N Industrial Park Drive, Hastings EVIl 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
For Teflon' Coated Sorinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon Coated
For Polyester Coated Sprinklers: Belleville Spring-Exposed
Ordering Information: (Also refer to the current Viking price list.)
Order Microfaste and MicrofastHPO Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin-
ish and then the appropriate suffix for the temperature rating to the sprinkler base part number.
Finish Suffix: Brass = A, ChromeEnloye = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflone = N
Temperature Suffix (°F/°C): 1350/570 = A, 1550/680 =B, 1750/790 = D, 200°/93° = E, and 286°/141° = G
For example, sprinkler VK302 with a 1/20 thread, Brass finish and a'155 ¶/68 °C temperature rating = Part No.. 06662BAB
Available Finishes And Temperature Ratings: .
Refer to Table 1.
Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book:)
Sprinkler Wrenches:
Standard Wrench: Part No. 10896W/B (available since 2000).
Wrench for Coated and/or Recessed Sprinklers: Part No. 12144W/B0 (available since 2003)
Optional Protective Sprinkler Cap Remover/Escutcheon Installer. Tool"" Part No. 15915 (available since 2010.)
NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B.
"A 1/20 ratchet is required (not available from Viking).
""Allows use from the floor by attaching a length of 10 diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808.
Sprinkler Cabinets:
Six-head capacity: Part No. 01724A (available since 1971)
Twelve-head capacity: Part No. 01725A (available since 1971)
INSTALLATION
Refer to appropriate NFPA Installation Standards.
OPERATION
During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and
sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern
to extinguish or control the fire.
INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.
AVAILABILITY
The Viking Microfast5 and MicrofastHPe Quick Response Pendent
Sprinklers are available through a network of domestic and
international distributors.. See The Viking Corporation web site for
the closest distributor or contact The Viking Corporation.
GUARANTEE
For details of warranty, refer to Viking's current list price schedule
or contact Viking directly.
Wrench
Rats Protective
Sprinkler
Cap
10896 (D ID:
Figure 1: Standard Sprinkler Wrench 10896W/B
December 20, 2010 Sprinkler 41c
MICROFASTO AND
MicrofastHP® QUICK % 1 11(1 I%IGj lI.i[11UI1M
RESPONSE PENDENT
SPRINKLERS
The Viking Corporation, 210 N Industrial Park Drive, Hastings NIl 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES
At Our
NMI RM- "'Wou J11M0HSQ
Ordinary 135 'F (57 'C) 100 'F (38 'C) Orange
Ordinary 155 'F (68 'C) 100 'F (38 'C) Red
Intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow
Intermediate .. 200 'F (93 'C) 150 'F (65 'C) Green
High 286 'F (141 'C) 225 'F (107 'C) Blue
Sprinkler Finishes: Brass, Chrome-Enloy, White Polyester, Black Polyester, and Black Teflon'
Corrosion-Resistant Coatings: White Polyester, Black Polyester, and Black Teflon
Footnotes
The sprinkler temperature rating is stamped on the deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.
Refer to specific installation standards.
corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These
tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat-
ible with or suitab'e brine proposco environment. rorauiomauc spriniciers, me coatings inoicaieo are dppIIu w we epueu eIeuvi wuy.
Note that the spring is exposed on sprinklers with Polyester and Teflon coatings.
WORMENOW
reml
Sprinkler Wrench I"
7 12144V/BW* for
/
I installing coated I and/or recessed IN
'pendent sprinklers
with protective caps. r '
slide the
4 '' wrench sideways
around the protective
---------- cap, ensuring engage- U rierrt with the sprinkler
wrench fLats, iEA 1/2' ratchet is required
(not available from Viking)
Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers
066668 VK352 3/4" 20 m?n
067658 VK352 1/2" 15 mm
06718B9
06720B9
06932B
VK329 112" 1.15 mm
VK331 1/2" 15 mm
VK331. - I 10 mm
Sprinkler Thread Size
Base SIN
Part No' NPT BSP
12282 VK317 1/2" 115 mm
ri
Sprinkler 41d December 20, 2010
i
MICRO FAST® AND
MicrofastHP® QUICK. TECHNICAL1
RESPONSE PENDENT
SPRINKLERS
The Viking Corporation, 210 N Industrial Park Drive, Hastings (VII 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com
Sprinkler I Thread Size Nominal I Overall 1 Listings and Approvals'
Base ' SIN I K-Factor Length (Refer also to Design Criteria on page 41e.]
Part No.' J NPT I BSP J U.S. J metric2 J Inches J mm J cULus4 NYC' J VdS I LPCB J CE
Standard Orifice
06662B I VK302 I -1/2" 115 mm I 5.6 I 80.6 I 2-1/4" I 58 I AIX..BlY I AIX, BIY I A3 A3X. B3Y I C3X.E3Y11 I
I I I •. •I I
Large Orifice
8.0 115.2 2-3/8" 60 AIX, SlY AIX, B1Y A3 A3X C3"
8.0 115.2 2-3/8" 60 AIX, SlY AiX, SlY A3 - -
Small Orifice6
2.8 403 2-3/16" 56 AIX, B1Y AIX, B1Y --
4.2 57 2-114" 58 AIX, B1Y AIX, B1Y -- - --
4.2 57 2-3/8" 60 - -- A3 -- G212
Maximum 250 PSI (17 bar) WWP
Standard Orifice
Nominal
K-Factor
Overall
Length
Listings and Approvals3
(Refer also to Design Criteria on page 41e.)
U.S. metric2 Inches mm cULus4 NYC1° VdS LPCB
5.6 80.6 2-1/4" 58 AIX, B1Y AIX - - -
Maximum 250 PSI (17 bar) WWP
Small Orifice9
I I I
C3X, E3Y'3
1229010 1 VK342 J 112" 115 mm I 2.8 40.3 2-3/16" J 56 AIX, SlY J AIX
-- -- - I -
Approved Temperature Ratings
A - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), Approved Escutcheons
and 286 "F (141 "C) Approved Finishes X - Standard surface-mounted escutcheon or
B - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), and 200 "F 1 - Brass, Chrome-EnIoy, White the Viking Microfast Model F-i Adjustable
(93 "C) Polyester°7, Black Polyester6.7, Escutcheon
C - 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and 286 "F and Black Teflon67 (141 "C) Y - Standard surface-mounted escutcheon or
2 - Brass and Chrome-Enloe the Viking Microfast6 Model F-i Adjustable D - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), and 286 "F
(141 °C) 3 - Brass, Chrome-Enloy6, White Escutcheon or recessed with the Viking
E - 155 "F (68 "C), 175 "F (79 "C), and 200°F (93 "C) Polyester?. and Black Polyester7 Micromatic6 Model E-i or E-2 Recessed
F - 155°F (68 "C), 175°F (79°C), and 286 "F (141 "C) Escutcheon
C- 155 "F (68 "C)
Footnotes
'Base part number is shown. For complete part number, refer to Viking's current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.
Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada.
5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA.
6 cULus Listed as corrosion resistant.
Other colors are available on request with the same Listings and Approvals as the standard colors.
B Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated
wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or
internally galvanized.
6 The sprinkler orifice is bushed.
'°Ajepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16.
11 -t Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003.
12 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170.
' ®MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008.
V_
December 20, 2010 Sprinkler 41 e
I . MICROFAST® AND
1111"
N
V __________________ McrofastHP5 QUICK TECHNICAL - RESPONSE PENDENT
SPRINKLERS ............-
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.corn
cULus Listing Requirements:
MicrofasP and MicrofastHPO Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with
the latest edition of NFPA 13 for standard spray sprinklers.
Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by
the installation standards being applied, with hydraulically calculated wet systems only).
The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed.
IMPORTANT: Always refer to -Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to 'page
QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor-
dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS
or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,
whenever applicable.
Ceiling Opening Size:
2-5/16' (58.7 mm) mlrllnUrl I 2-1/8'
2-1/2' (63,5 mm) maximum (54 )
112,
(15
NPT
mm)
-\__
I (
mom
2-1/4' II LII Ill (445 mm) 1-1/2' (38.1
1-5/8' IJ
(41 mm)
I I II! (58 mm) (50.8 mm) K Maximum Ii AW Minimum
. j
.
Pendent Sprinkler
06662B (VK302)
InstalLed with a
standard 1/8' surface-
mounted escutcheon. Installed with a Microfast
Model F-i Adjustable Escutcheon
Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon
I 2-1/8' Ceiling Opening Size: I 2-1/8' "1
(54 mm)
I
2-5/16" (58.7 mm) minimum i (54 mm)
2-1/2" (63.5 rim) maximum
1-1/8' (28.6 mm)
Minimum (44.5 mm)
Maximum
Installed with a Micromatic
Model E-1 Recessed Escutcheon
2'
tyi
11/8' (28.6 mm)
(50.8 mm) Minimum
Maximum
-
Installed with a thread on
Model E-2 Recessed Escutcheon
4: Sorinkler VK302 Dimensions with the Model E-I and E-2 Recessed Escutcheons
Sprinkler .41f December 201 2010
_______________________ MicrofastHP® QUICK
11(1 NG4
MICRO FAST® AND
RESPONSE PENDENT
SPRINKLERS
The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
* MiërofastQuick Respons'e PeidenUSrink1ers _ AEW.iIcheDi 3PPIIW$f P PSI (12
Sprinkler Thread Size Nominal K-Factor Overall Lengthj FM Approvals' SIN Base Part No.' (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm
Standard Orifice
066628 VK302 112' 15 mm 5.6 80.6 J 2-1/4' J 58 J A2X, B2Y
Large Orifice
066668 VK352 3/4" 20 mm 8.0 115.2 2-3/8" f 60 AiX, B1Y
06765B VK352 1/2" 115 mm 8.0 115.2 2-318" 60 AiX, B1Y
Small Orifice4
0671886 J VK329 1/2" 15 mm 2.8 40.3 2-3116" 56 AiX
Approved Escutcheons
Approved Temperature Ratings Approved Finishes X - Standard surface-mounted escutcheon or the Viking
A - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 1 - Brass and Chrorne-Enloy' Microfast Model F-i Adjustable Escutcheon
200 "F (93 "C), and 286 "F (141 "C) . 2. Brass, Chrome-Enloy,WutoPotyester, Y - Standard surface-mounted escutcheon or the
L3 -135 "F (57 "C), 155 "F (68 "C), 175"F (79 "C), and Black Polyester Viking Microfast Model F-i Adjustable Escutcheon
"F and 200 (93.'C) or recessed with the Viking Micromatic Model E-i
or E-2 Recessed Escutcheon
Footnotes
Base part number is shown. For complete pall number, refer to Viking's current price schedule.
2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.
FM Approved as quick response control mode standard spray Non-storage sprinklers. For specific application and installation requirements, reference
the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0).
Other, colors are available on request with the same Listings and Approvals as the standard colors.
6 The sprinkler orifice is bushed.
FM Approval Requirements:
The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the
FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including
Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements,
hydraulic design, ceilingslope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling.
NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria,
tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data
page 131a-e for Intermediate Level In-Rack Sprinklers.
IMPORTANT: Always refer to Bulletin Form No. F,091699 - Care and Handling of Sprinklers. Also refer to page
011I-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac-
cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,
APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and
standards, whenever applicable.
Form No. F_081296 Replaces page 41a-f, dated November 16, 2010.
(Added FM Approval for sprinkler 06765B.)