HomeMy WebLinkAbout421 TAMARACK AVE; ; AS110046; Permit6/20/24, 8:51 AM AS110046 Permit Data City of Carlsbad Sprinkler Permit Job Address: 421 TAMARACK AV Permit Type: SPRINK Parcel No: 2060420200 Lot #: 0 Reference No.: Permit No: AS110046 Status: ISSUED Applied 3/23/2011 Approved: 3/23/2011 Issued: 3/23/2011 PC #: Inspector: Project Title: URBINO RESIDENCE RESIDENTIAL FIRE SPRINKLER SYSTEM Applicant: MILLENNIUM FIRE PROTECTION SUITE.F 101 COPPERWOOD WY OCEANSIDE, CA 760-722-2722 Owner: ALDERSON REVOCABLE TRUST 05-29-02 1122 COUNTRYW000 LN VISTA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 260 0 260 0 about:blank 1/1 MILLENNIUM FIRE PROTECTION CORP. Urbino Residence Overhead Fire Sprinkler Material Submittal MILLENNIUM FIRE PROTECTION C 101 COPPERW000 WAY, SUITE H OCEANSIDE, CA 92058 760-722-2722 Job Name : Urbino Residence Drawing : FP-1 Location : 421 Tamarack Ave. Remote Area : I Contract : 11-006 Data File :11-006 UrbinoResid.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP Page 1 Urbino Residence Date 03/16/11 HYDRAULIC CALCULATIONS for Project name: Urbino Residence. Location: 421 Tamarack Ave. Drawing no: FP-1 Date: 3/16/11 Design Remote area number: 1 Remote area location: Master Bed Room Occupancy classification: NFPA 13D Density: .05 - Gpm/SqFt Area of application: 375 - SqFt Coverage per sprinkler: 400 - SqFt Type of sprinklers calculated: 4.9K SSP Concealer No. of sprinklers calculated: 2 In-rack demand: n/a - GPM Hose streams: 5- GPM Total water required (including hose streams): 63.4 - GPM @ 40.3 - Psi Type of system: Tree Volume of dry orpreaction system: n/a - Gal Water supply information Date: 3/15/11 Location: Hydrant at address Source: Gauge Hydrant Name of contractor: MILLENNIUM FIRE PROTECTION CRP Address: 101 COPPERWOOD WAY, SUITE H, OCEANSIDE, CA 92058 Phone number: 760-722-2722 Name of designer: J. Van Kolken Authority having jurisdiction: Carlsbad Fire Prevention Notes: (Include peaking information or gridded systems here.) MOST DEMANDING PRESSURE WAS CALCULATED IN THIS REPORT Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) MILLENNIUM FIRE PROTECTION CRP Page 2 Urbino Residence Date 03/16/11 City Water Supply: Demand: Cl - Static Pressure : 79.2 Dl - Elevation : 10.936 C2 - Residual Pressure: 59.2 D2 - System Flow : 40.303 C2 - Residual Flow : 100 D2 - System Pressure : 63.424 Hose (Demand) : 5 D3 - System Demand : 45.303 Safety Margin : 11.154 150 140 130 p120 R110 E10° 90 -- Cl 80 U70 02 R6° E5° ____ V D3 -- ___ ____ ______ 40 30 ,- 20 .7Z 10 DT ..... .. _____ 10 20 30 40 50 60 70 80 90 FLOW (N 1.85) C2 Computer Programs by Hydratec inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MILLENNIUM FIRE PROTECTION CRP Page 3 Urbino Residence Date 03/16/11 Fitting Legend Abbrev. Name Y2 % 1 1% 1% 2 --2Y2 3 3Y2 4 5 6 -8 10 12 14 16 18 20 24 Blvt Ball Vic 728 Thrd 0 0 0.5 1 1.7 0.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 E NFPAI39O'StandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 S NFPA13Swing Check Valve 4 5 5 7 9 11 14 16 19 22 27 32 45 55 65 76 87 98 109 130 T NFPAI39O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD MILLENNIUM FIRE PROTECTION CRP Page 4 Urbino Residence Date 03/16/11 Node No Elevation K-Fact ___________-____ Pt Actual Pn Flow Density Actual Area Press Req. 01 21.25 4.9 16.7 na 20.02 0.05 400 16.7 03 21.25 4.9 17.13 na 20.28 0.05 400 16.7 02 21.75 18.08 na 04 21.75 18.54 na 05 21.75 27.24 na TR 20.0 28.98 na BR 1.0 38.68 na UG -4.0 41.28 na MTR -4.0 50.33 na SRC -4.0 63.42 na 5.0 The maximum velocity is 13.58 and it occurs in the pipe between nodes MTR and SRC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 5 Urbino Residence Date 03/16111 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 01 21.250 4.90 20.02 1 iT 9.563 10.000 150 16.700 to 1E 3.825 13.387 -0.217 02 21.750 20.02 1.101 0.0 23.387 0.0682 1.595 Vel = 6.75 0.0 02 20.02 18.078 K Factor = 4.71 03 21.250 4.90 20.28 1 IT 9.563 10.000 150 17.127 to 1 3.825 13.387 -0.217 04 21.750 20.28 1.101 0.0 23.387 0.0698 1.633 Vel = 6.83 0.0 04 20.28 18.543 K Factor = 4.71 02 21.750 to 04 21.750 04 21.750 to 05 21.750 05 21.750 to TR 20 TR 20 to BR I BR 1 to UG -4 UG -4 to MTR -4 MTR -4 to SRC -4 SRC 20.02 1.25 2E 9.523 12.000 150 18.078 0.0 9.523 0.0 20.02 1.394 0.0 21.523 0.0216 0.465 VeI= 4.21 20.28 1.25 IT 9.523 81.750 150 18.543 4E 19.046 28.570 0.0 40.3 1.394 0.0 110.320 0.0788 8.697 Vel = 8.47 0.0 1.5 2E 11.656 12.500 150 27.240 0.0 11.656 0.758 40.3 1.598 0.0 24.156 0.0405 0.979 Vel = 6.45 0.0 1.5 lBlvt 2.477 20.750 150 28.977 Is 13.113 15.590 8.229 40.3 1.598 0.0 36.340 0.0405 1.473 Vel = 6.45 0.0 1.5 1 5.828 5.000 150 38.679 0.0 5.828 2.166 40.3 1.598 0.0 10.828 0.0405 0.438 Vel = 6.45 0.0 1.5 3E 17.484200.000 150 41.283 2F 5.828 23.312 0.0 40.3 1.598 0.0 223.312 0.0405 9.052 Vel = 6.45 0.0 1 IBM 0.956 22.000 150 50.335 1 9.563 10.519 5.000 * Fixed loss = 5 40.3 1.101 0.0 32.519 0.2487 8.089 Vel = 13.58 5.00 Qa= 5.00 45.30 63.424 K Factor= 5.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 tqCo Fire Suppression & Building Products Technical Services 800-381-93121 +1-401-781-8220 www.tyco-fire.com ,a rapid response HOME FIRE SPRINKLER SYSTEM Series LFII Residential Sprinklers 49 K-Factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Domed-Plate Concealed Pendent 4.9 K-Factor Sprinklers (TY2234) are decorative, fast response, frangible bulb sprinklers de- signed for use in residential occupan- cies such as homes, apartments, dor- mitories, and hotels. The Cover Plate/Retainer Assembly conceals the sprinkler operating components above the ceiling. The domed profile of the cover plate pro- vides aesthetically appealing sprin- kler design with lower flow rates than can be achieved by lower profile cover plates. The separable two-piece de- sign of the Cover Plate and Support Cup Assemblies allows installation of the sprinklers and pressure testing of the fire protection system prior to the installation of the ceiling or application of a finish coating. Also, the separable "push-on and thread-off" two-piece design of the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment. The Series LFll Residential Sprinklers (1Y2234) are intended for use in the fol- lowing scenarios: wet and dry pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any oc- cupancy per NFPA 13 Historically residential sprinklers, based on their Listing, have been limited to wet pipe sprinkler systems to assure speed of water delivery for a given prescribed design area (num- ber of design sprinklers). The Series LFII Residential Domed-Plate Con- cealed Pendent Sprinklers (TY2234) Listing now offers the laboratory ap- proved option of designing dry pipe residential sprinkler systems. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Domed-Plate Concealed Pendent Sprinklers need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprin- kler systems, as is customary for den- sity/area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Domed-Plate Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of de- sign sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. These Residential Sprinklers have a 4.9 (70,6) K-Factor that provides the required residential flow rates at re- duced pressures, enabling smaller pipe sizes and water supply requirements. The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) have been designed with heat sensitivity and water distribu- tion characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. SEPTEMBER 2010 The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) are shipped with a Dispos- able Protective Cap. The Protective Cap is temporarily removed for instal- lation, and it must be replaced to pro- tect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Protective Cap. When ceiling install- ation is complete, the Protective Cap must be removed and the Cover Plate Assembly installed. The Protective Cap must be removed to ensure proper performance of the sprinklers. NOTICE The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compli- ance with this document and the ap- plicable standards of the National Fire Protection Association, in addition to the standards of any authorities hav- ing jurisdiction. Failure to do so may im- pair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The in- stalling contractor or sprinkler manu- facturer should be contacted with any questions. TFP45O TFP45O Page 2 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Maximum Coverage Maximum Spacing Areat°1 Ft. (Maximum 2-Inch Rise (Greater than 2-Inch Rise up (Greater than 4-Inch Rise up Ft. x Ft. (m) for 12-Inch Run) to Maximum 4-Inch Rise to Maximum 8-Inch Rise (m x m) for 12-Inch Run) for 12-Inch Run) 155°F (68°C) 155°F (68°C) 155°F (68°C) 12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 19 GPM (71,9 LPM) (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 15.0 psi (1,03 bar) 14 x 14 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 19 GPM (71,9 LPM) (4,3 x 4,3) (4,3) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 15.0 psi (1,03 bar) 16 x 16 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 19 GPM (71,9 LPM) (4,9 x 4,9) (4,9) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 15.0 psi (1,03 bar) 18 x 18 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 19 GPM (71,9 LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 15.0 psi (1,03 bar) 20 x 20 20 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) 24 GPM (90,8 LPM) (6,1 x 6,1) (6,1) 16.7 psi (1,15 bar) 18.4 psi (1,27 bar) 24.0 psi (1,65 bar) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design under the Design Criteria Section. TABLE A SERIES LFII RESIDENTIAL DOMED-PLATE CONCEALED PENDENT SPRINKLERS (TY2234) NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS DRY PIPE SYSTEM Minimum Flow N and Residual Pressure Maximum Maximum Coverage Area °1 Spacing For Horizontal Ceiling Ft. x Ft. Ft. (Maximum 2-Inch Rise for 12-Inch Run) (mxm) (m) 155°F (71°C) 12 x 12 12 13 GPM (49,2 LPM) (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 14 x 14 14 14 GPM (53,0 LPM) (4,3 x 4,3) (4,3) 8.2 psi (0,57 bar) 16x16 16 15 GPM (56,BLPM) (4,9 x 4,9) (4,9) 9.4 psi (0,65 bar) 18 x 18 18 20 GPM (75,7 LPM) (5,5 x 5,5) (5,5) - 16.7 psi (1,15 bar) 20 x 20 20 22 GPM (83,3 LPM) (6,1 x 6,1) (6,1) 20.2 psi (1,39 bar) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design under the Design Criteria section. TABLE B SERIES LFII RESIDENTIAL DOMED-PLATE CONCEALED SPRINKLERS (TY2234) NFPA 13D HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEMS TFP45O Page 3 of 6 Model/Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NYC Approved under MEA 44-03-E The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers are only listed with the Series LFII Residential Domed-Plate Concealed Pendent Cover Plates having a factory applied finish. For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psil/2 (70,6 LPM/barl/2) Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Frame ....................Brass Button...................Bronze Sealing Assembly.........Beryllium Nickel w/ Teflon* Bulb (3 mm) ................Glass Compression Screw.........Brass Deflector.................Copper Button Ejection Spring......Stainless Steel Support Cup................Steel Cover Plate................Brass Retainer ..................Brass Cover Plate Ejection Spring......Stainless Steel "Registered trademark of Dupont Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, falls away to expose the Sprinkler Assembly. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb allowing the sprinkler to activate and flow water. Design Criteria The RAPID RESPONSE Series LFII Residential Domed-Plate Concealed Pendent 4.9 K-Factor Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with the fol- lowing criteria. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. For dry systems, corrosion-resistant or internally galvanized pipe shall be uti- lized with the sprinklers described in this data sheet. For dry systems not using CPVC, pen- dent sprinklers shall be installed on re- turn bends, where the sprinklers, return bends, and branch line piping (that is, potential areas for trapped water) are in areas at or above 40°F (40C). Refer to technical data sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. When corrosion-resistant or internally galvanized pipe and fittings with a po- table water supply is utilized, return bends need not be installed. However, any portion of the piping that has the potential to trap water must be main- tained at or above 40°F (4°C) unless provision to drain such areas is provid- ed and maintained dry. Water Delivery When using the Series LFII Residential Pendent Sprinklers (TY2234) in dry pipe sprinkler systems, the require- ments for "Dry System Water Delivery" per Section 8.3.4.3 of the 2010 edition of NFPA 130 apply. For a residential hazard, in no case shall the time of wa- ter delivery exceed 15 seconds for the most remote operating sprinkler. Hydraulic Design (NFPA 13D and 13R) The minimum required sprinkler flow rate for systems designed to NFPA 130 or NFPA 13R are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the min- imum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. NOTICE The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when de- signing dry pipe systems. There is no need to increase the design area, as is the case for density/area systems, in accordance with U.S. Patent 7,712,543. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B for NFPA 130 and 13R as a func- tion of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 GPM/ sq. ft. over the "design area" com- prised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when de- signing dry pipe systems. There is no need to increase the design area, as is the case for density/area systems, in accordance with U.S. Patent 7,712,543. The Series LFII Residential Domed-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Obstruction To Water Distribution Sprinklers are to be located in ac- cordance with the obstruction rules defined by NFPA 13 for residential sprinklers. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. TFP45O Page 4 of 6 Sprinkler Spacing The minimum spacing between sprinklers is 8 feet (2,4 m). The maxi- mum spacing between sprin- klers cannot exceed the length of the coverage area (Table A) being hydraulically calculated; maxi- mum 12 feet for a 12 ft. x 12 ft. cover- age area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The RAPID RESPONSE Series LFll Residential Domed-Plate Concealed Pendent 4.9 K-Factor Sprinklers (TY2234) must be installed in accor- dance with the following instructions: Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). Obtain a leak-tight 1/2 inch NPT sprinkler joint by applying a minimum- to-maximum torque of 7 to 14 ft. lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Install the pendent sprinkler in only the pendent position with the cen- terline of the sprinkler perpendicu- lar to the mounting surface. Remove the Protective Cap. Lf.III.I Do not remove the Sprinkler Strap (Figure 1) until the sprinkler system is to be placed in service. With pipe-thread sealant applied to the pipe threads, and using the W-Type 7 Wrench shown in Figure 2, install and tighten the Sprinkler/ Support Cup Assembly into the fit- ting. The W-Type 7 Wrench will ac- cept a 1/2 inch ratchet drive. Replace the Protective Cap by push- ing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent dam- age to the Deflector and Arms dur- ing ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. NOTICE As long as the Sprinkler Strap (Fig- ure 1) or the Protective Cap (Figure 3) remains in place, the system is considered to be "Out Of Service". After the ceiling has been com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap and the Sprinkler Strap. Note: Refer to Technical Data Sheet TFP700 regarding instructions for the removal of the Sprinkler Strap. Push the Cover Plate/Retainer Assembly into the Support Cup, and as necessary, make the final adjust- ment of the Cover Plate with respect to the ceiling by turning the Cover Plate/Retainer Assembly clockwise until its flange just comes in contact with the ceiling. If it becomes necessary to remove the Cover Plate, it can be removed by unscrewing in a counter-clockwise direction. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer Assembly cannot be engaged suf- ficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The RAPID RESPONSE Series LFIl Residential Domed-Plate Concealed Pendent 4.9 K-Factor Sprinklers (TY2234) must be maintained and ser- viced in accordance with the following instructions: NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tems from the proper authorities and notify all personnel who may he affect- ed by this action. Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, can delay sprinkler op- eration in a fire situation. Owners must assure that the sprinklers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feath- er, duster; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Exercise care to avoid damage to sprin- klers before, during, and after installa- tion. Never paint, plate, coat, or oth- erwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: were modified or over-heated. were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. are leaking or exhibiting visible signs of corrosion. were exposed to corrosive products of combustion but have not operated, if you cannot easily remove combus- tion by-products with a cloth. have a cracked Bulb or have lost liquid from the Bulb. Refer to the Installation section in this data sheet. For the Cover Plate/Retainer Assembly, the following items apply: When properly installed, a nominal 3/32 inch (2,4 mm) air gap exists between the lip of the Cover and the ceiling, as shown in Figure 3. This air gap is necessary for proper sprinkler operation. The air gap al- lows heat flow from a fire to pass below and above the Cover, helping to assure appropriate release of the Cover in a fire situation. If repaint- ing the ceiling after installation is re- quired, exercise care to ensure that new paint does not seal off any of the air gap. Do not pull the Cover relative to the Retainer. Separation may result. Never repaint factory-painted Cov- ers. When necessary, replace Cov- ers with factory-painted units. Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local re- quirernents and/or national codes. TFP45O Page 5 of 6 SEALING ASSEMBLY WRENCH FLATS DISPOSABLE IL SPRINKLER STRAP (SEE INSTALLATION I SECTION) DEFLECTOR THREAD INTO I SUPPORT UNTIL MOU SURFACI FLUSH CEILIN , FRAME / / (1/2' NPT) , 'S / BUTTON , / SUPPORT I I I CUP WITH I ROLL FORMED I I I THREADS 11&7----LCOMPRESSION BULB I SPRINKLER/SUPPORT CUP SCREW ASSEMBLY I I RETAINER 'a- WITH THREAD 01 101 TABS ii EJECTION II SPRING WRENCH RECESS f. PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 SPRINKLER WRENCH OVER LATE SOLDE TABS ( COVER PLATE/RETAINER ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLERS (TY2234) (Shown with Disposable Sprinkler Strap) 2-1/2 DIA. SPRINKLER- (63,5 mm) 1/2° (12,7 mm) FACE OF SUPPORT CUP 1/2° \ THREADED SPRINKLER \ ASSEMBLY \ NPT ADJUSTMENT FITTING COVER / PLATE 3/32 GAP 1-3/16°±1/47 DISPOSABLE RETAINER - (30,2 mm ±6,4 mm) MOUNTING _ SURFACE COVER- SPRINKLER- 15/16' 1/4(6,4 mm) OPERATED rRETAINER SUPPORT CUP I (23,8 mm 3/4' (19,1 mm) SPRINKLER ASSEMBLY ASSEMBLY 3-5/16 DIA. (84,1 mm) TIP PROTECTIVE CAP FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLERS (TV2234) INSTALLATION DIMENSIONS / DISPOSABLE PROTECTIVE CAP TFP45O Page 6 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Association, and/or the standards of any authorities having jurisdiction. Materials found by TFSBP to be defec- tive shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete in- formation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer- chantability and fitness for a narticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on fail- ure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Series LFII Residential Domed-Plate Concealed Pendent Sprinkler (1Y2234), K=4.9, without Cover Plate Assembly, P/N 51-873-1-155. Cover Plate Assembly Cover Plate Assembly having a (speci- fy) finish for the Series LFll Residential Domed-Plate Concealed Pendent Sprinkler (TY2234), K=4.9, and P/N (below). Chrome .................... PIN 56-873-9-135 Signal white (a) (RAL 9003) ................ PIN 56-873-4-135 Pure White (b) (RAL 9010) ................ PIN 56-873-3-135 Custom ...................P/N 56-873-X-135 Previously known as Bright White. Eastern Hemisphere sales only. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001, Copyright 0 2008-2010 Tyco Fire Suppression & Building Products. All rights reserved. tqC0 Fire Suppression & Building Products Technical Services 800-381-93121+1-401-781-8220 www.tyco-fire.com Series TY-FRB — 28,42,56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TV- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. JULY 2010 Model/Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2- NPT TY1231: Pendent 2.8K, 1/2 NPT TY2131: Upright 4.2K, 1/2' NPT TY2231: Pendent 4.2K, 1/2- NPT TY3131: Upright 5.6K, 1/2 NPT TY3231: Pendent 5.6K, lIZ NPT TV4131: Upright 8.0K, 3/4 NPT 1Y4231: Pendent 8.0K, 3/4' NPT TY4831: Upright* 8.0K, lIZ NPT TY4931: Pendent* 8.0K, lIZ NPT Ftern Hemisphere Sales Only TFPI7I SSU * DEFLECTOR P1 fm 3/4° NPT TFPI7I Page 3 of 10 7/16 (11,1 mm) ESCUTCHEON ssu * NOMINAL PLATE SEATING DEFLECTOR NPT MAKE-IN 1/2 SURFACE 6* 5T12-3116" 7/16 (11,1 mm) I NOMINAL (55,6 mm) 1 MAKE-IN 2,6 mm) FLATS (38,1mm) 1-1/2" WRENCH 1/2 NPT SSP DEFLECTOR * CROSS SECTION UPRIGHT PENDENT STYLE 100r20 RECESSED ESCUTCHEON 27/8* (73,0 mm) DIA. RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly * Temperature rating is indicated on deflector or adjaceni to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY3131) AND PENDENT (TV3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 1/2 (12,7 mm) ESCUTCHEON NOMINAL PLATE SEATING MAKE-IN 3/411 SURFACE W I I NPT / 2-5!'16. (58,7 mm) 1-9/16 (39,7 mm) SSP DEFLECTOR* STYLE 30 or 40 RECESSED ESCUTCHEON 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV4131) AND PENDENT (TY4231) SPRINKLERS ao K-FACTOR, 314 INCH NPT TFPI7I Page 4 of 10 7/16 (11,1 mm) SSU NOMINAL DEFLECTOR MAKE-IN 1/2 NPT 5 Ii 7/16' A I\ (11,1 mm) 2-1/4' ---11 Pi I NOMINAL 7,2 mm) 2 MAKE-IN -3/16' 1-9/16' WRENCH (39,7 mm) FLATS SSP*-.. CROSS 1/211 NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly * Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4831) AND PENDENT 'TV4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi'/2 (40,3 LPM/bar112) K=4.2 GPM/psi112 (60,5 LPM/barl'2) K=5.6 GPM/psi112 (80,6 LPM/barl/2) K=8.0 GPM/ps11/2 (115,2 LPM/bar1/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button .............. brass/Copper Sealing Assembly.........Beryllium Nickel w/Teflont Bulb ......................Glass Compression Screw........Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze t Registered Trademark of Dupont Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1351F/570C and 3/32 inch (2,4 mm) for the 2860F/1410C temperature ratings. Obtain a leak-tight 1/2 inch NPTsprin- kier joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I WHITE*** POLYESTER LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2, 3,4, 5, 6, 7 Blue 1, 2, 3, 5 155°F/68°C Red I 175°F/79°C Yellow 200°F/93°C Green 286F/141°C RECESSED PENDENT (TY3231)* Figure 10 135°F/57C Orange 1, 2, 4, 5 N/A 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green 286F/141°C Blue RECESSED PENDENT (TY3231)** Figure 11 135°F/57C Orange 1, 2, 3, 4, 5 Blue N/A 155°F/68°C Red 175°F/79C Yellow 200F/93°C Green 286F/141°C 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2,3, 4,5,6,7 Blue 1,2, 5 155F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (TY4231)* Figure 12 135F/57°C Orange 1, 2, 5 Blue N/A 155°17/68°13 Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C RECESSED PENDENT (TY4231)** Figure 13 135F/57C Orange 1, 2, 3, 5 Blue N/A 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286F/141°C 8.0 112" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2, 4, 5, 6 1, 2, 5 155°F/68°C Red 175F/79°C Yellow 200F/93C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME I WHITE LEAD FACTOR BRASS I PLATED POLYESTER COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1131) 1/2" NPT 75 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (TY3231) N/A PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (1Y4931) 175 PSI 1/2" NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TABLE C MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. (.1t1II Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: were modified or over-heated. were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. are leaking or exhibiting visible signs of corrosion. were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. TFPI7I Page 8 of 10 2-7/8 DIA. - 5/8±1/4 (73,0 mm) 3/4° (19,1 mm) (15,9*6,4 mm) 2-1/4 DIA. 1/4(6,4 mm) I FACE OF (57,2 MOUNTING SPRINKLER PLATE FITTING &L/ 3,2 mm) -i MOUNTING SURFACE ,, ,/'' CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20.6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 5/8±1/4 2-7/8" DIA. (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4° (6,4 mm) I (57,2 mm) I I FACE OF MOUNTING SPRINKLER PLATE I FITTING I - - (3,2 mm) MOUNTING f SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) I TY-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4(6,4 mm) I ?- •/,.!_J- I FACE OF T (57,2 mm) I I MOUNTING SPRINKLER PLATE I FITTING I_ 1/8" / (3,2 mm) I MOUNTING / SURFACE//f f CLOSURE SERIES (33,3 mm) TY-FRB 1-1/16" (27,0 nm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8° DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) I FACE OF (57,2 mm) MOUNTING ;- I SPRINKLER PLATE I FITTING 1/8° (3,2 mm) t \ / MOUNTING / SURFACE/ SERIES 1-1/4" (31,13 mm) CLOSURE TY-FRB 1° (25,4 mm) FIGURE 9 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. 2-7/8 DIA. (73,0 mm) 3/4 (19,1 mm) 2-1/4' DIA. (57,2 mm) 1/4 (6,4 mm) MOUNTING DI AT 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING TFPI7I Page 9 of 10 2-7/8° DIA. (73,0 mm) 3/4' (19,1 mm) 2-1/4° DIA. 1/4 (6,4 mm) I I (57,2 mm) ;i;-1 MOUNTING I DI±T I 2-7/8 DIA. (73,0 mm) 1/2 (12,7 mm) 2-1/4' DIA. (57,2 mm) ' 1/4 (6,4 mm) I I Ti MOUNTING I - DIAT I 5/8±1/4° (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1/2±1/8' (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE I SERIES CLOSURE 1/8° (3,2 mm) I 1-1/4"(31,8 mm) 3/4"(19,1 mm) T__\__ MOUNTING SURFACE CLOSURE SERIES 1-1/4° (31,8 mm) 1' (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH P110-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3 mm)1 TY-FRB 13/16' (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 1/2±1/8' (73,0 mm) 1/2' (12,7 mm) r (12,7±3,2 mm) 2-1/4' DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING I SPRINKLER I PLATE 2- 1/8' I FITTING (3,2mm) I MOUNTING SURFACE/ CLOSURE SERIES 1-5/16' (33,3 mm) 1YFRB 1-1/16 (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END 'A' USED FOR 1/2 NPT MODELS) WRENCH RECESS (END "B' USED FOR 3/4' NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS t. PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 10 of 10 P/N 57- XXX- X- XXX I L MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2°NPT) TY2131 341 4.2K PENDENT (1/2°NPT) TY2231 370 5.6K UPRIGHT (1/2°NPT) TY3131 371 5.61K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831° 361 8.0K PENDENT (1/2°NPT) TY49311* SPRINKLER TEMPERATURE L FINISH RATINGS 1 1 NATURAL BRASS 135 135°F (57°C) 4 I WHITE POLYESTER I I 155 1 155°F (68°C) 3 WHITE (RAL901O)° 175 175°F (79°C) 9 1 CHROME PLATED 200 200°F (93°C) 7 I LEAD COATED I I 286 1 286-F (141-C) ° Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer- chantability and fitness for a particular Duroose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NOT Thread Connections Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table 0). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Refer to Technical Data Sheet TFP770. Copyright 0 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved. Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap Type Size Range - 3/4" thru 2' CPVC pipe Material - Pre-Galvanized Steel Function - Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to sup- port CPVC pipe from under a flat horizontal surface, such as a ceiling. For this type of installation, use the TOLCO® Fig. 23, Double Fastener Strap for CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (1) 1/4' x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features - Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design pro- tects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw furnished with the product, this is the minimum size fastener acceptable. It is rec- ommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been know to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and CPVC pipe size. Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./1100 3/4 27A 1/16 1/16 51h 5/16 9 1 211A6 1A8 1W16 6 5/16 9 11/4 31A6 1/8 13/16 61h 5/16 11 1½ 3/i6 13/4 1A6 7 5/16 12 2 33/4 21/8 1A6 8 5/16 - 15 D OFFICMANUFACTURIPIG FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type rom Size Range - 3/4" thru 3" CPVC pipe Material - Pre-Galvanized Steel Function - Intended to perform as a hanger/restrainer to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. The Fig. 23 also functions as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features - Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as instal- lation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights cpvc Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./1100 3/4 314 1A6 1A* 51h 5/16 9 1 334 111A6 1/16 6 5/16 9 11/4 4/16 2%2 1A6 61h 5/16 11 1½ 4A6 2/32 13A6 7 5/16 12 2 474 2/16 1A6 8 5/16 15 21/2 10/32 211/16 1/16 9 5/16 22 3 117/8 3 1/16 10 5/16 25 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 28 "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe C® US LISTED Size Range - 3/4" through 2" Material - Carbon Steel, Pre-Galvanized Function - Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking Features / Flared edge design protects CPVC pipe from any rough or abrasive surfaces \ , Unique twist and lock design holds pipe firmly in place and allows retrofit type . B of installation The Stand Off design eliminates the need for wood block extension C Can be installed on horizontal or vertical piping regardless of mounting "......-' surface orientation. Attaches easily to wood structure with two hex head self-threading screws furnished with product. Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws. U.L. Listed as a hanger and a restrainer for fire sprinkler piping. Approvals - Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by - Figure number and pipe size. PATENT # 10446292 FIG79 (I) REOUIRED .....FIQ.2Th HIGH WE (2) REOUID OFHGER JjJ Dimensions • Weights HANGER APPLICATION HANGER& RESTRAINT Pipe Approx. F*20 APPLICATION A B Size Wt. 3/4 31/3 2 3½ 180 4, 1 36 2A6 31h .210 .J1 ( 11/4 3% 2% 31/2 .225 Ij 1½ 4 21h 3½ .310 F8-----..I i 2 . 41h 211/16 3/8 .340 I FI26 FIG2E .....FOID - ._ ................... ..........._.. ................ -. [i_TIJIiIIJiIIIJ OFFICMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879. PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger C@US LISTED Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2' thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21h" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4' thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/a 25/8 - 400 11 3/4 3/8 8mm or 10mm 31/s 21h 400 11 1 3/8 8mm or 10mm 33/8 2% 400 12 11/4 3/8 8mm or 10mm 33/4 2/e 400 13 11/2 3/8 8mm or 10mm 37/8 2/s 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21h. 3/8 10mm 55A 41A 600 27 3 3/8 10mm 57/s 4 600 29 31/2 3/8 10mm 7% 51/ 600 34 4 3/8 10mm 73A 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 6Y4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • F(: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com C®US US1tD Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Pre-Galvanized Steel .- • '..: •.. - Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed qnly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 'PH: 951.737.5599 • FM: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 980 - Universal Swivel Sway Brace Attachment CUS LISTED Size Range One size fits bracing pipe 1" thru 2', TOLCO 12 gauge channel, and all structural steel up to 1/4" thick. Material - Carbon Steel Function - Multi-functional attachment to structure or braced pipe fitting. Features - This product's design incorporates a concen- tric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation - The Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. ed rn To Install - Place the Fig. 980 onto the "bracing pipe'. Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note - The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000, Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish. PATENT #6,273,372 Dimensions • Weights Max. Design **Max. Design A B H* Load Lbs. Load Lbs. Approx. wtjloo (cULus) (FM) 51/4 1/8 17/32 2765 2800 132 Available with hole sizes to accommodate up to 3/4' fastener. Consult factory. ** Load shown is allowable with brace installed, between 30° - 90°. No reduction of load based on brace angle is required. Lateral Brace TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Longitudinal Brace Fig. 4L CUS LISTED Longitudinal In-Line' Sway. Brace Attachment Size Range - 21/2" through 8" IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Approvals - Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" - 8". Approved by Factory Mutual Engineering (FM), 21/2" - 8" pipe. Installation Instructions - The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Galvanized and HOG finish. Order By - Figure number, pipe size and finish. ............. ... 4-Way Riser Brace (Plan view) Dimensions • Weights Bolt Max. Rec. *Max Rec. Approx. Sizes A C D Size Load Lbs. Load Lbs. wt./100 (cULus) (FM) 21h 6/16 21/2 2/4 1/2 2015 3000 253 3 7 23/4 31/16 1/2 2015 1550 268 4 81h 3% 311,1,6 1/2 2015 1550 348 5 93/4 37/8 43A 1/2 2015 1450 380 6 11 1h 5 51/8 1/2 2015 1450 640 8 131/4 611A6 61/8 1/2 2015 1450 728 * Load shown is allowable with brace installed, between 30° - 90°. No reduction of load based on brace angle is required. FM approved when used with 1 , 11/4", 11/2 or 2° Sch. 40 brace pipe. TOLCO® brand bracing components are designed to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE. • CORONA, CA 82878 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtoko.com KG-505-W-8 Grooved KT-505W 300 lb. WWP Bronze Ball Valves Fire Protection Valve • Threaded or Grooved Body Style • Full Port Design 1 - 2' • Standard Port Design 21/2' • Accepts Internal Supervisory Switche 300 PSI/20.7 Bar Non-Shock Cold Water CONFORMS TO MSS SP-1 10 • FM APPROVED . UL LISTED FOR INDOOR AND OUTDOOR SERVICE. CALIFORNIA STATE FIRE MARSHAL LISTING NO. 7770-1243:103 APPROVED BY NEW YORK CITY M.E.A. 218-04-E WITH APPROPRIATE NYC INDICATOR. MATERIAL LIST PART SPECIFICATION Body Bronze ASTM B 584 Alloy C84400 Ball chrome Plated Brass ASTM B 124 Alloy C37700 Seat Ring carbon-filled [FE Thrust Washer Reinforced TFE ncificon Resista Stem Bronze ASTM B 371 Alloy C69430 Stem 0-Ring Nitrile Retaining Washer Brass Retaining Ring Steel Ground Wire Screw Steel 505-8 Act Assy. Brass Body End Bronze ASTM B 584 Alloy C84400 Mounting Screw Steel Lock Washer Steel Handle Pin Brass Hand Wheel Steel/plastisol coated (11/4" 21/2") Brass Tee Handle (1 I Indicator Flag Painted Steel Body Gasket Elastomer lB. Lead Screw 0-Ring Nitrile Thrust Washer Anti-friction Polymer Cover Gasket Neoprene Flag Seal 0-Ring Nitrile Tamper-Proof Screw Stainless Steel Pipe Plug (-4 units) Stainless Steel (Not shown) Refer to page 41 for details for TS-2M Switch Kit. DIMENSIONS-WEIGHTS-QUANTITIES Size In. mm. Threaded In. mm. A Grooved In. mm. Threaded In. mm. Dimensions B Grooved C D In. mm. In. mm. In. mm. E In. mm. F In. mm. 6 In. mm. Weight Cvt Threaded Grooved Box Master Value Lbs. Kg. Lbs. Kg. Wy. Ctn. Wy, 1 25 3.33 85 - - 1.66 42 - - 2.11 54 3.81 97 2.31 59 6.14 1561.75 44 57 6.1 2.77 - - 1 10 1114 32 4.18 106 - - 2.09 53 - - 2.46 624.21 107 2.72 69 6.33 161 3.50 89 103 7.1 3.23 - - 1 8 1½ 40 4.70 119 - - 2.35 60 - - 2.95 74 4.46113 2.97 75 6.33 161 3.50 89 143 8.1 3.68 - - 1 4 2 50 5.15 131 6.71 170 2.57 65 3.36 85 3.69 94 4.67 119 3.18 81 6.33 181 3.50 89 245 10.7 4.86 9.7 4.40 1 4 21h 65 5.65 144 7.28 185 2.92 74 3.64 93 3.75 95 4.67 119 3.18 81 6.33 161 3.50 89 183 13.0 5.91 12.6 5.73 1 4 t Note: Cv is defined as the flow in GPM that a valve will carry with a pressure drop of 1.0 psi when the media is water at 600 F. AOV!D II NIBCO INC WOAI D HEADQUARTERS • 1516 MIODLEBUFtY ST. • EIKHART. IN 46516-4740 • USA • PH: 1.600.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH +1.574.295.3327 • F,(: 4 1.574.295.3455 www.tibco.com PART SPECIFICATION Body Bronze ASTM B 584 Alloy C84400 - . Stem Stainless Steel ASTM A 582 Alloy C30300 Spring 316 Stainless Steel Disc Holder Stainless Steel Type 301 Disc Water, Oil or Gas (8una-N) Steam (PTFE) (Y) Seat Screw Stainless Steel ASTM A 276 Alloy S43000 Body End Bronze ASTM 8 584 Alloy C84400 1-480 Threaded S-480 Solder B__ Class 125 Bronze Ring Check® Valves incification Inline Lift Type • Resilient Discs • Spring Actuated flSIStart>' 125 P51/8.6 Bar Saturated Steam (PTFE Disc) 250 PSI/17.2 Bar Non-Shock Cold Working Pressure CONFORMS TO MSS SP-80 MATERIAL LIST T-480-Y (PTFE Disc) NPTxNPT DIMENSIONS -WEIGHTS -QUANTITIES Size In. mm. In. A mm. Dimensions B In. mm. In. C mm. T-480 In. mm. S-480 Master Lbs. Kg. Ctn. Oty. 3/ 10 2.00 51 1.38 35 1.44 37 0.41 0.19 0.44 0.20 100 1/2 15 2.06 52 1.38 35 1.19 30 0.36 0.16 0.40 0.18 100 3/4 20 2.25 57 1.63 41 1.31 33 0.48 0.22 0.52 0.24 100 1 25 2.63 67 2.00 51 1.50 38 0.77 0.35 0.85 0.39 50 11/4 32 2.94 75 2.38 60 1.69 43 1.14 0.51 1.28 0.58 30 11/2 40 3.31 84 2.75 70 2.00 51 1.63 0.74 1.75 0.79 30 2 50 3.69 94 3.38 86 2.31 59 2.27 1.03 2.70 1.23 10 Ordering: The 1.480 and S480 both have standard Buna-N Discs. Also available with PTFE (Y) Discs; specify 1-480-V or S-480-V. W' Wu 2' require ½ pound pressure to open. S-480-Y (PIFE Disc) CxC NIBCO check valves maybe installed in both horizontal and For detailed Operating Pressure, refer to Pressure Temperature Chart on page 111. vertical lines with upward flow or in any intermediate position. Warning - Do Not Use For Reciprocating Air Compressor Service. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLE8URY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com The AGF Manufacturing Inc. Model 1000 TESTMIDRAIN® provides both the test function and the express drain function for a wet fire sprinkler system. The Model 1000 complies with the requirements of NFPA-13, NFPA-13R, and NFPA-13D. The Model 1000 TESTANDRAIN® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Available in a full range of sizes from 34" to 2" NPT and BSPT, with all specifiable orifice sizes /e" (2.8K), 7Ae" (4.2K), ½" (5.6K), 17/32" (8.0K), We" (11.2K, ELO), 34" (14.0K, ESFR), and K25 as required by NFPA 13, 2007 Edition (see reverse). The orifice size is noted on the indicator plate and the valve features a tapped and plugged port for system access. A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent unintentional alarm activation. Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are available for all TESTAtIDRAIN® valves. Valve and orifice size must be specified when ordering. MODEL 1000 - FRONT VIEW, VERTICAL INSTALLATION FROM BRANCH SYSTEM ACCESS PORT STREET T EL STREET _.II1][III] TO DRAIN OR PIPE TO DRAIN RIGHT HAND/STRAIGHT INSTALLATION TESTANDF.AIN is a registered trademark of AGF Manufacturing Inc. DS1000 10/09 DIMENSIONS Orifice Size Available: 3/°, /16°, ½", 17/32°, ELO (5/8 )*, ESFR (3/4 )*, & K25** TO DRAIN MATERIALS Handle: Steel Stem: Rod Brass Ball: C.R Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Handle Stop: Steel APPROVALS UL and ULC Listed (EX4019) FM Approved NYC-BSA No. 720-87-SM MODEL 1000 - PLAN VIEW FRONT VIEW - HORIZONTAL INSTALL SIZE A B C D E F C H 3/4" 51A6" 1½" 23/16 35A" 33/8" 113/16 4A6" 63/8" (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (1117 mm) (162.5 mm) 1½" 26" 35A" 33/8" 113/16" 49A6 63/8" (128 mm) (37.5 mm) 1 (57 mm) (93 mm) (86 mm) (46 mm) (117mm) (162.5 mm) 11/4" 57/16" 111A6" 29/16" 41/4" 35/16" 115A6" 59/16" 51/2" (163 mm) (43 mm) (65 mm) (108mm) (83 mm) (51 mm) (141 mm) (1192 mm) 1Y2" 67A6" 113A6" 3¼" 51/16" 37/8"2%"81/4" 107/8" (1163 mm) (45 mm) (81.5 mm) (127 mm) (99 MM) (67 mm) (207 mm) (274 mm) 2" 6/16" 113A6" 31/4" 51/16" 37/8" 2%" 81/4" 107/8" (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) * Available on 11/4" to 2" size units only ** Available on 11/2" and 20 size units only THE MODEL 1000 PROVIDES ALL OF THE FOLLOWING.. From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - shall be provided with a drain & 8.16.2.4.3 connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection.., with a shutoff valve and plug not less than 1", at least one of which shall be brass. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name:___________________________ 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Architect: Fax: 610-240-4906 www.testandrain.com Contractor: Engineer: (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH - SMALL PIPE Stock No. 1111100 U.S. Patent No. 3921989, Canadian Patent No. 1009680 Other Patents Pending Install VS-SP VS-SP in systems that are not subject to variable water pressure. Failure to do so will result in false alarms. AcAUTION This device is not intended for applications in explosive environments. The Model VS-SP is a vane type waterfiow switch for use on wet sprinkler systems. These devices may be used as sectional flow indicators on large sprinkler systems and on smaller sprinkler systems such as mobile homes and residential dwellings. The VS-SP does not have a retard to prevent false alarms due to water surges. Therefore it should NOT be used on systems with variable water pressure supplies except in the case of elevator recall. Installation These devices may be mounted in horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will he accessible. The units should not be installed within 6" (15cm) of a valve, drain or fitting which changes the direction of the water flow. Select the propr paddle for the pipe size and type of TEE used. See Fig. I for instruc:ions on how to change the paddle. The unit has a I' NPT bushing for threading into a non- corrosive TEE. UL, ULC, CSFM and NYBSA Listed, CE Marked Service Pressure: Up to 250 PSI (17,2 BAR) Minimum Flow Rate for Alarm: 10 GPM (38 LPM) Maximum Surge: 18 FPS (5,5 m/s) Enclosure: Die-cast, red enamel finish Cover held in place with tamper resistant screws Contacts: One set of SPOT (Form C), standard Second set optional, see below: IS Amps at 1251250VAC 0.5 Amps at 125 VDC 0.25 Amps at 250VDC 2.5 Amps at 30 VDC resistive Conduit Entrance: One opening for 1/2" conduit Usage: Listed plastic, copper and schedule 40iron pipe For pipe sizes - I" (251nm), 1-114" (32mm), 1-1/2' (38mm). and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" C PVC, one for I" CPVC (Central), one for 1" Nibco threaded tee, and one for 1-1/2" threaded (Japan). Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA4/1P55 rated enclosure -use with appropriate conduit fitting. Temperature range: 40°F to 120°F (4,5°C to 49°C) Service Use: Automatic Sprinkler NF PA-13 3 One or two family dwelling 4PA-131) Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Extra Contacts Switch Kit, Stock No. 0090013 (Extra Contacts Switch is Field Installed) Cover Tamper Switch Kit, Stock No. 5420220 See Fig. 2 for proper TEE size, type and installation. Use no more than three wraps of teflon tape as thread lubricant. Screw the device into the TEE fitting as shown in Fig. 2. Care must be taken to properly orient the device for the direction of waterfiow. The vane must not rub the inside of the TEE or bind in any way. The stem should move freely when operated by hand. Testing Check the operation of the unit by opening the inspector's test valve at the end of the sprinkler line, or the drain and test connection if a test valve is not provided. If there are no provisions for testing the operation of the flow detection device on the system, application of the VS—SP is not recommended or advisable. Potter Electric Signal Compa iy, 1.1C -2081 Craig Road, St. Louis. MO, 63146-4161 • Phone: 800-325-3936/Canada888-882-1 833• www.pouersignal.com PRINTED IN USA MFG. #5400769 - REV \' PAGE I OF 2 5/08 S. (E,)POTTER The Symbol of Protection VS-SP VANE TYPE WATERFLOW ALARM SWITCH - SMALL PIPE Fig. I Fig. 2 OPTIONAL SECOND SWITCH AVAILABLE I H __ H IF REQUIRED. FLOW 0 SWITCH KIT I I I I I ''- APPROX. I STK 110090013 0 MOUNTSO I I I ARROWON BUSHING POINTS IN DIRECTION 0 OF WATER DEITH DIRECTION OF FLOW WATER FLOW I' NPT THREADED FITTING ON - - ALL SIZES Screw the device into the tee fitting as shown. Care must be taken to RUN OF properly orient the device for the direction of waterfiow. On sat tees, no threaded bushings, inserts, or adapters are permitted, unless THE TEE Important: .. MAY BE they comply with the dimensions listed in the chart below. There are 12 paddles furnished THREADED Important -The depth to the inside bottom of the tee should have the with each unit. Due for each size of OR SVEAT following dimensions: threaded, sweat or plastic TEE as TYPE described in Fig. 2. These paddles have raised lettering that shows the pipe size and type of TEE that they are to he used with. The DIRECTION t use more than three wraps ot'teflon tape. proper paddle must be used. The OF WATER Do u paddle must be properly attached FLOW (see drawing) and the screw that holds the paddle must be securely Lightened. Switch information I Typical Control Panel Connections Switch Terminal Connections Clamping Plate Terminal TOP OF SWITCH JEIL SWITCH ACTION COM I N.C. non N.C. LOCAL BELL/HORN CONNECTION N.O. - N.C. BELL POWER OR HORN DWG. #769—I END—OF—LINE RESISTOR TYPE P i o= N.C.N.1 _ COM- OPEN CIRCUIT TYPE TO -7 PANEL CLOSED CIRCUIT TYPE N.O. COM.,,, TO 7NC. PANEL OWC CAUTION An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Due to the possibility of unintended discharges caused by pressure Surges, trapped air, or short retard tunes. waterfiow switches that are monitoring wet pipe sprinkler Systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Note: The Model VS-SP has one SPDT switch. An optional second switch is available if required. For example, one switch would connect to an annunciator panel, and the optional switch could be used to operate a local bell. Order Switch Kit No. 0090013. Testing The frequency of inspection and testing for the Model VS-SP and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). PRINTED IN USA MFG. 95400769 - REV V PAGE 2 OF 2 5108 <2> (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (10 square electrical box for indoor use or on a model BilK-i weatherproof backbox or BBX-i deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm). 8" (200mm) and 10' (250mm) Voltages Available: 24VAC I2OVAC I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note I) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK- I weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA128 1750080 .12A 90 77 10(250) 12VDC MBA1210 1750060 .12A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) I20VAC PBAI206 1806120* .05A 92 83 8(200) 120 VAC PBA 1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. in outdoor or wet installations, bell must be mounted with weatherproof backbox. BilK-I or BBX-l. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC •2081 Craig Road, St. Louis, MO, 631464161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV PAGE 1 OF 2 5/08 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2 conduit entrance p(8 /u c3/4 (141.: ....._.,._.., (86) - IS 4114" (1(181 I>VGU 770.2 ®POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Fig. I SWIll 716.1 Wiring (rear view) Fig. 3 A.C. BELLS WIIrrIi (IN) WIllIE (01fF) C6L FROM CONTROL PANELOR PRECEDING HELL HLAC6IIN) CArnON: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WhEN USINOAC BELLS.TEIhMINAIE EACH EXIRA WIRE SEPARATELYAF'IER LAST BELL. 2• uRIS-OF-LINE RESIStOR IS NOT REQUIRED ONAC HELLS. 0Wrn776-3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90' AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). mø r, - Failure to install striker down will pruvent bell from operating- PRINTED IN USA MPG. #5400776 - REV Y PAGE 2 OF 2 5/08