Loading...
HomeMy WebLinkAbout1 LEGO DR; ; AS980139; Permit3/8/24, 11:07 AM AS980 139 Permit Data City of Carlsbad AUTOMATIC SPRINKLER-COMM Job Address: I LEGO DR Permit Type: ASC Parcel No: Lot #: 0 Reference No.: Permit No: AS980139 Status: ISSUED Applied 8/4/1998 Approved: 8/4/1998 Issued: 8/4/1998 PC #: Inspector: Project Title: IMAGINATION CENTER LEGOLAND PARK CAFE Applicant: Owner: COSCO FIRE PROTECTION 321 EAST GARDENABL GARDENA CA 213 321-5155 Fees ($) Add'l Fees ($) Total ($) Balance ($) 300 0 300 0 about:blank 1/1 MR86159 Product Data Sheet Firestopping 07270 Firestop Systems Inc. Jan.96 Systems Inc. PRODUCT NAME 4100.STM (Non Sag) Fire and Smoke Stop Sealant MANUFACTURER Firestop Systems Inc. 12187 Industrial Rd. Surrey. B.C. Canada V3V 3S1 (See Technical Services below for contact numbers) .3. COMPLIANCE Warnock Hersey Professional Testing Services Ltd. is a fire endurance testing agency accredited by the International Conference of Building Officials (ICBO) in the United States. In Canada, Warnock Hersey is accredited by the Building Standards Council or Canada (SCC). Certifications provided by Warnock Hersey have equal status with those provided by Underwriters Laboratories (UL) and Underwriters Laboratories Canada (ULC). Firestop Systems Inc. 41001VS TM (Non Sag) fire and smoke stop sealant has bepn tested by Warnock Hersey and meets or exceeds the requirements of: CAN/ULC S115-M85. CAN/ULC S101-M88 ASTM E- 814. ASTM E - 119 4. PRODUCT DESCRIPTION J!OO.VS" sealant is a high performance, modified latex gun grade elastomer product designed to stop the passage of fire, smoke, fumes, bacteria and water through fire rated separations. Jjoo,sTM sealant forms an air and water tight bond with most common construction materials in any combination including wood, concrete, gypsum wallboard (GWB). steel, copper, aluminum and PVC or CPVC jacketed electrical wires. 4100N5TM sealant produces a durable and flexi:Ie seal after curing. Features: Adheres to dry or damp surfaces Excellent joint movement capabilities Priming not required Non toxic. Safe, easy and economical to use and clean up. Adheres to concrete, metal, wood and most common construction materials Provides an airlbacteria seal and a fireproof acoustic seal Fully water and mildew resistant after surface curing. Remains flexible and fully waterproof after curing. 5. USES: When installed correctly within system designs recognized and tested by a ICBO or SCC accredited agency. 4I00VST4,ill control the spread of fire, smoke, fumes and water before, during and after exposure to open flames up to 1000°C (1850°F) for as long as 2 hours. Primary sealing applications include. Openings with or without penetrations Cable trays Curtainwall expansion joints to 12"(300mm) width Horizontal expansion joints to 12" (300mm) width EMT and conduit COMPATIBILITY DATA 4101J•5TM has been tested in our in house laboratories and is compatible with all the listed types of metal and plastic pipe and plastic coated wires. LIMITATIONS Dynamic joint movement in excess of 50% Temperature before cure below 3°C (37°F) Slower cure rates in cold or damp weather Horizontal expansion joints exceeding 12° (300mm) width Vertical expansion joints exceeding 4" (100mm) width 4109NS (Non Sagging) FIRE AND SMOKE STOP SEALANT INSTALLATION DATA To install, remove standing water as well as excess dirt and dust. Install mineral wool insulation at 4 to 6 lbs per cubic foot density, loose or blanket, compressed a minimum of 25% to a minimum depth of 3 1/2" (87mm). (Optional: For superior installation, fill mineral wool to full depth of the penetration.) Apply 4/00.VSTM to a dry film sealant depth of 1/4" (6mm). Do not install if the temperature with (24) hours of installation is expected to fall below 3°C (37°F). 4100A'STMmust be installed in compliance with the tested and listed system design. CAUTION: Mineral wool may cause eye, skin and respiratory tract irritations. Avoid contact with eyes, skin and clothing. Recommend use of gloves and goggles. Refer to material safety data sheet from insulation material supplier. STORAGE, HANDLING AND FIRST AID 410oNSr.'i5hould not be stored in an area where the temperature exceeds 49°C (120°F) or falls below 3°C (37°F). Keep product stored under protective cover in its original container. Products have a minimum shelf life of (2) years and a stock rotation program is recommended. FIRST AID: In case of contact with eyes, flush with water and consult a physician. In case of contact with skin, clean with soap and water thoroughly. Consult a physician if eye/skin irritation develops. See MSDS for additional information. AVAILABILITY 4100,VSTM5 available in: 10 US fl. oz. (300 mL) cartridges 30 US. fi. oz. (850 mL) cartridges 3.17 US Gallon (12 ltr) plastic pails MAINTENANCE AND REPENETRATION 410OvSiM does not require maintenance after installation. If re- penetration is necessary the seal can be Cut and the penetrating item replaced. The seal can then be restored easily by applying a new layer of sealant. 41001VST4 will form a full chemical bond and adhere to itself. WARRANTY Firestop Systems Inc. warrants to its purchasers that each quantity of 4100,VSTM shall be the same kind designated or specified by it and no other warranty (except by title) shall be implied. TECHNICAL SERVICES Complete technical information and product literature is available from Firestop Systems Inc. and its authorized resellers or: Toll Free: ---------------------------------------------1.800.810.1788 Facsimile --------------------------- - ------ ---- ------- 1.604.580.1783 Email address ----------------------------firestopdeepcove.com Internet address--------------http://www.deepcove.com/firestop Laboratory services and our in-house test furnace are available for specialty applications. 14. TYPICAL PROPERTIES As Supplied Working Time--------------------------------------------------------1 Hour Paintable alter----------------------------------------------------48 Hours Full cure and adhesion ---------------------------------------7-14 days Color 4100.VSTM ------------------------------- - ------------------------ Grey As Cured after 7 days @ room temp ASTM 0 2240 Durometer hardness. Shore A ------ ASTM 0412 Elongation. Max--------------------------------------------35% Extension--------------------------------------------- ----------25% Compression -----------------------------------------------15% Disclaimer: Al technical advise, recommendations and service rendered by the seller are gratis. They are based on Technical data which The seller believes to be reliable and are intended for use by persons having skills and know-how at their own discretion and risk. In no event will the seller be liable for any consequential damages arising out of the use Of this product. Gypsum Wall Fire Separation (with metal sleeve) Horizontal Fire Separation (Concrete) v, t,0. I (Concrete Block) .. Vertical Fire Separation System Design Instructions Metal Sleeve Item 1A FIRESTOP SYSTEMS Firestop Systems Inc. 12187 Industrial Rd., Surrey. B.C., Canada, V3V 3S1 Design No. FSIPHV 120-01 Single and Multiple Penetrations Horizontal or Vertical (floor/ceiling and walls) Test Standards; ASTM E-814, UL 1479, CAN/ULC S115 Test furnace internal positive test pressure differential Exceeds minimum 2.5 Pa (0.01 inches water) Penetrating Max Annular Fire Fire/Hose Temp Rating Material & Size Hole Size Space "F" rating "FH" rating 'FTH" rating Steel and Cast Iron pipe (1" to 3') Sch 10 & up 11 In 1/4" -4" 2 Hours 2 Hours 35 Mm" Steel and Cast Iron pipe (314' to 8') Sch 10 & up 16 In 1/4' - 4" 2 Hours 2 Hours 19 Mm"" Steel and Cast Iron pipe (81/V to 16') Sch 40 24 In 1/4' - 4" 2 Hours 2 Hours 14 Mm EMT/Steel conduit pipe (W to 1") Sch 10 & up 9 I 1/4' -4" 2 Hours 2 Hours 60 Win- EMT/Steel conduit pipe (1W' to 6') Sch 10 & up 14 In 1/4' - 4" 2 Hours 2 Hours 30 Mm" Copper Pipe and tubing up to 2" ID 10 In 1/4 - 4" 2 Hours 2 Hours 50 Mm" BX/Teck cables up to 2 1/2 00. (Plastic Jacket) 7 In 1/4" - 2'4" 2 Hours 2 Hours 2 Hours Loomex/Romex electrical wiring to 1 '/' 6Y2 In 1/4' - 2'." 2 Hours 2 Hours 2 Hours 25Pr Telephone cable (Plastic Jacket) 4 In 1/8' - 1" 2 Hours 2 Hours 2 Hours 5/16" 00 Cablevision wire (Plastic Jacket) 4 In 1/8". 1 2 Hours 2 Hours 2 Hours 1. Penetrating Item: Centered or offset in hole, see table above. Single penetrations for steel pipes 6' (150mm) to 16" (400mm), up to 5 penetrations for steel pipe, conduit or electrical wiring 1" (25mm) or less in diameter, up to 3 penetrations for copper pipe when two are Va" (13mm) or less. Steel pipes over 8" (200mm) in diameter require ceramic fiber filler material (item 4). a) Metal sleeve: Minimum 28 Ga or heavier metal sleeve fit tightly into the opening with a maximum annular space around sleeve to GWB of 1/4" (6mm). Metal sleeve used to support mineral wool filler material (item 4) within hollow cavities. 2. Floor/Ceiling or Wall Fire Separations: 1 and 2 hour ASTM E-i 19 or CAN/ULC Si 01 metal or wood framed fire rated gypsum wallboard (GWB) floor/ceiling/wall fire separations. (Note all GWB assemblies require metal sleeves when using 4I0ONS) Cast in place normal or light density concrete floor/ceiling assemblies having a minimum cross section thickness of 4 1/2"(11 2mm) or C) Cast in place concrete wall assemblies having a minimum cross section thickness of 6" (150mm) or: d) Hollow or concrete filled unit masonry (concrete block) wall assemblies laid up with mortar having a minimum cross section thickness of 8" (200mm). Firestop System Component 1: Firestop Systems Inc. 4IOONS" (non-sag) for vertical or horizontal applications or 4100SL (self-leveling) for horizontal applications. Each product must be installed at a minimum thickness of V." (6mm) or 5100SP" (mastic) for vertical or horizontal applications sprayed into place with a minimum wet film thickness of 1/8" (3mm)( 120m11). Use 5100SP" only where the annular space does not exceed 2" (50mm). Always overlap 5100SP" on to the surface of the substrate a minimum of Y" (13mm). Do not thin 5100SP ffrestop mastic when spraying. Use equipment capable of applying 5100SP" as supplied. On GWB and metal sleeve installations use only 4100NS at a minimum film thickness of 1/4" (6mm). Firestop System Component 2: Filler material, Mineral rock wool or ceramic fiber insulation with a minimum density of 4-6 PCF (68 kg/m3) compressed a minimum of 25% into the annular space at a minimum depth of 31/2" (88mm). Recess filler material 1/4 (6mm) for 4100 series sealant placement. For 5100SP" applications do not recess filler material. On steel pipes over 8" (200mm) use ceramic fiber insulation filler material only. On GWB and metal sleeve installations fill to full depth of sleeve allowing 1/4" (6mm) for sealant placement on each side. WH Labeled Component "Use device In listing FSIPHV 120-07 to obtain 1, 2, or3 hour "FT" ratings on these items. First issue date; April, 1993 Last revision date; January, 1997 WARNOCk MERSEY LOOK FOR THE MARK