Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6115 CORTE DEL CEDRO; ; FA140004; Permit
4/4/24,12:01 PM FA140004 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA140004 6115 CORTE DEL Job Address: Status: ISSUED CEDRO Permit Type: FALARM Applied 2/4/2014 Parcel No: 2130700400 Approved: 2/12/2014 Lot #: 0 Reference No.: Issued: 2/12/2014 PC #: Inspector: Project Title: INDUSTRIAL STRENGTH TI—THE INTENT IS TO REPLACE THE EXISTING FIRE ALARM CONTROL UNIT AT THIS SITE THAT IS BEING USED TO MONITOR THE BLDG. FIRE SPRINKLER SYSTEM. NOTE: THE COMMUNICATION METHOD FOR THIS SYSTEM IS A GSM UNIVERAL WIRELESS ALARM COMMUNICATOR. THE COMMUNICATOR SHALL BE INSTALLED PER THE REQUIREMENTS OF NFPA72, 2013, SECTION 26.6.3.1. Applicant: BAY ALARM COMPANY 4883 RONSON CT SUTE C SAN DIEGO, CA 92111 714-719-9334 Owner: CRILLY MCGUIRE&HACKETT L L C 2045 ESPLENDIDO AVE VISTA CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 286 0 286 0 about:blank 1/1 4883 Ronson Court, Suite C San Diego, CA 92111 1 (800)470-1000 Contractor License #880138 1. PROTECTED PREMISE Industrial Strength 6115 Cone del Cedro Carlsbad, CA 92011 MONITORING COMPANY Bay Alarm Company 60 Berry Drive Pacheco, CA 94553 800-470-1000 California Alarm Operating License Number: ACO28 EQUIPMENT SUPPLIER & INSTALLER 4883 Ronson Court, Suite C San Diego, CA 92111 1 (800)470-1000 Contractor License # 880138 flts. puis have been reviewed fur apparent cntplIne Willi iht_ curt it applicable cutler and standards in force in iltejuristlicflon. The o'.nci or counacuil ir:iv utilii_i lid, re ct it uppuIt of all •tppltttion tot a building pet nut t iii the C \I CSS tiflticrstatttlillg that hits reviCu it n 5% 0 iCIIC\ es (tIC owlier or conIrarir II IliCit 1)1 otession.th engineer 01 architect lot sok rcspotisihilit fur lull eon p1 ance with said codes and standards. including the building code or for any responsihilty For deficiencies. errors. omisions or negligence in these plaits wheihr or not ttotcd in this review. J 4 Resiewer) RE('OMMENI) Al-'PROVAI. RE(()MMENI) Al'l'l)VAl. AS N( FA140004 EO THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance 01 a UL Certificate for the Alarm System and the Certificate is current under UI's Certificate Verification Service This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate Listed Service From PACHECO, CA Alarm Service Company (223646-006) Service Center (223646-006) BAY ALARM CO BAY ALARM CO 60 BERRY DR 60 BERRY DR PACHECO CA 94553 PACHECO CA 94553 The Alarm Service Company is Listed in the following Certificate Service Categories File Vol No CCN Listing Category BP643 - 1 CPVX [Burglar Alarm Systems] Central Station BP9248 -1 CRZH [Burglar Alarm Systems] National Industrial Security Systems BP8184 -4 CVSG [Burglar Alarm Systems] Mercantile S576 -1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31MAR2014* "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" I XR1 5ODNFC/XR55ODNFC SYSTEM FEATURES All above listed System Features On-board Ethernet connection for Network MonitoringTM Customizable check-in time and retry time Suitable for multi-site applications where the Internet or LAN/WAN is available Powerful addressable fire system Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Flash Updateable: No more firmware chips to replace Adaptive lechnologylM - Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. XRI50FC/XR550FC SERIES COMMERCIAL FIRE PANELS SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on • Multiple on-board status LEDs XR550FC • Up to 100 output schedules to control relays and panel outputs Up to 142 two-wire smoke detector or fire initiating zones on • 32 individual reporting areas, with common areas XR150FC • Output Groups: Maximum functionality—Minimum programming Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection Up to .7 Amps 12 VDC supervised bell output Up to 506 fully-programmable Form C relays Serial 3 Digital Dialer or CID reporting to multiple receivers Eight communication paths between the panel and Central Station Built-in remote or on-site feature upgrade capability 12.000 event buffer Multi-lingual menus available by user XRI50FC & XR550FC FIRE PANELS The XR1 5ODFC and XR55ODFC provide basic fire monitoring for any single site application. The XR1 500NFC and XR55ODNFC panels provide all the same basic fire monitoring as the XR15ODFC and XR5500FC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL The XR150FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DACt NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion. conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security the enclosure comes with a lock and key. KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PlC for power circuit protection. XRI 5OFC/XR55OFC TYPICAL NOTIFICATION/ANNUNCIATION Digital SLC Loop 2 Digital SLC Any expansion device Loop I can operate on SLC Loop I or 2 12or24VDC NAC 1 L 12or24VDC NAC 1 Sync Module Strobe Mini-Horn 12or24VDC L...... 505-12 or other 12/24VDC UL be 12 or 24 VDC Power Supply Sync Module Horn Stro Motor Bell Commercial Fire Approved Digital Power Supplies Annunciator Bus - Additional 630F Fire Command Centers 630F Fire Command Center FLEXIBLE COMMUNICATION The XR1500NFC and XR550DNFC has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger. multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the centralstation response time and limit dependence on automation literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path, the 263C or 263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. EIGHT COMMUNICATION PATHS Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the Central Station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength. and email status from the keypad. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard. presignaL cross zoning, or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR15OFC and XR55OFC provide up to 570 zones, programmable for a variety of fire applications. The system provides Class B 12 VDC powered zones, two on-board and four on the 715 Module, plus eight panel burglary zones. Up to 60 zones are available on 15 keypad addresses and up to 100 zones are available on each built-in LX_BusTM using Expansion Modules. FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verily zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds afterthe reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. - NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR150FC/ XR550FC system. Up to three Class B modules can be mounted within the FACR Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature allows a single technician to check the panel response to fire, burglary. panic and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones. find individual zone numbers, check the DC-Bus for Missing. Overlapping and/or Extra zones, and much more, all from any DMP LCD keypad. FLASH UPDATEABLE The XR150FC and XR550FC panels accept software updates from a remote location using Remote LinkTM software. When new XR150FC/XR550FC feature updates release, perform the flash update remotely. OUTPUTS ..........................:i:: ........ The XR150FC and XR55OFC allow the use of two SPDT relay outputs and four open collector outputs, that may be activated by zone or system events, by schedule, through the User Menu or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. MULTI-LINGUAL DISPLAYS For additional flexibility, keypads attached to the XR1 SOFC and XR550FC panels can display keypad Status List and User Menu text using multiple languages. The user has the option to select the language to use. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location and other zones can be programmed to display and be monitored at different keypad locations. 12,000 EVENT MEMORY Allows the user to view the last 10.000 door accesses or 2.000 system events that occurred over the past 45 days. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® WindoWSTM. The XR150FC and XR550FC include an interface connection for installers to use to connect a laptop computer. KEYPADS 630F LCD Remote Fire Command EXPANSION MODULES 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class-13 Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion, 4 Form C relays, 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs CELLULAR COMMUNICATORS 263C CDMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (All require a 381 cable) AUXILIARY MODULES 860 Relay Output Module 865 Style WIX Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module POWER SUPPLIES 505-12ILX 5 Amps @12VDC 505-12L 5 Amps @12VDC 505-12A 5 Amps @12VDC PULL STATIONS 850 Series Pull Stations SMOKE/HEAT DETECTORS 521B/BXr Conventional Smoke, CleanMe 521 LX/LXT Addressable Smoke/Heat. CleanMe ACCESSORIES 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18" Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1 R Network Enabled Receiver Compatable with Central Station Receivers that accept Standard CID. DD. or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS 1100X Receiver 1100XH High Power Receiver 1100R Repeater 1103 Universal Transmitter. External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165H5 Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VDC Battery Models 365.366. 368 or 369 Output Rating Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For UL installations, total bell, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: Material Cold-rolled steel (Red) ORDERING INFORMATION XR150DFC-R XR150 Fire Control Panel XR150DNFC-R XR150 Fire Control Panel with Network XR55ODFC-R XR550 Fire Control Panel XR550DNFC-R XR550 Fire Control Panel with Network _ LISTINGS AND APPROVALS Refer to the XR150FC/XR550FC Installation Guide 0-1297). XR150FC/ XR550FC Programming Guide 0-1232) and specific compliance listings for installation and programming requirements necessary to meet a particular approval FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance. nfl 111 lflflfl I UU.041.ML0L I UIIIIJ.IJJIII 500 North Partnership Boulevard .v.. .'d • I' 'jrkj '"""' . . esugned. Engineered & Assembled prungfield. Missouri 65803-8877 . n Springfield. Missouri 1uperior ilotification kiptions DMP Notification Modules provide quality supervision for faults, such as grounds, shorts, and opens. 12 or 24 VDC, UL Listed devices Devices alert on-site personnel of fire and burglary alarms Silence switch can disable module bell output during service and maintenance Select the module that is best for your application. 8659 866,867 TAOTIRCAT ........... NOTIFICATION V DOU:FEATURES 867 FEATURES Po'red from panel or auxiliary power supply Provides Steady, Pulse, Temporal Code 3, and California Suitable for use witi 1 VDC or 24 VDC devices Schools Code belt outputs Supervised Silence Switch disables the belt output Provides supervision for opens, shorts, and ground fault du— g service or main'enance conditions on the bell circuit Provide sLpervised Style W 2-wire circuit for notification On-board status LED indicates panel communication is., appliances . good _-i . On-board Power Supply Monitor LED indicates toss of Provides cne 4-wir circuit or two 2-wire circuits power from an auxiliary power supply : Provides Style Y, Z. W, or X notification circuit for the Easy rotary addressing; no difficult binary switches connection of aD!ian:es . Ideal for mounting near notification devices Pro'iidescne lróuhe arid one Ground Fault LED Connects to the 4-wire LX-Bus on XR500 Series, XR200, or XR200-485 panels Supervises UL 111e:, p:larized notification devices Allcws irislallaticn of nultiple Style W notification , • -. devices Supervis auxiliary p wer supply, :; 867 MODULE SPECIFICATIONS Operating Voltage LX-Bus: 8.0 to 15.0 VDC Bell Power: 10.2 to 28 VDC Operating Current LX-Bus: 30mA maximum Bell Power: 30mA standby, 80mA maximum Alarm-Switching Current 5 Amps at 12 or 24 VDC Module Dimensions 3" x 5" LISTINGS AND APPROVALS Underwriters Laboratories (UL) Listed UL 864 Fire Protective Signaling UL 985 Household Fire Warning UL 1023 Household Burglary FCC Part 15 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 i -ri ilA.FIII INSTALLING THE 865 DESCRIPTION 867 DESCRIPTION NOTIFICATION MODULES The 865 is suitable for use with 2- or The 867 connects to the panel LX-Bus You can install the Notification 4-wire Style Y, Z, W, or X circuits. It and provides one supervised Style Modules in any of the panel enclosure provides one Trouble and one Ground W circuit, and four LEDs to indicate three-hole mounting locations using Fault LED and a set of trouble contacts circuit Trouble and Ground Fault the plastic standoffs provided, to indicate off normal conditions, conditions. NOTIFICATION APPLIANCES The 865, 866, and 867 Modules easily connect notification appliances, such as horns and strobes. By connecting the appliances in parallel, it is possible to connect several appliances to one module. Refer to the module installation sheet for more information. AUXILIARY POWER SUPPLY You can connect a maximum 5 Amp, 12 or 24 VDC UL listed auxiliary power supply to the Notification Modules to support alarm power requirements beyond the panel alarm output capacity. SILENCE SWITCH OPERATION The Silence switch on the Notification Modules allows technicians to test or perform maintenance on the DMP fire system without sounding the building's fire alarm notification devices. POWER SUPPLY SUPERVISION The panel can supervise the auxiliary power supply through the normally closed trouble contacts on the power supply that also connect to terminals 7 and 8 on the 866 and 867 Modules. When the bell circuit is in a bad condition, the modules indicate the bad condition to the panel. 865 SELECTABLE CIRCUIT STYLES By setting a jumper on the 865 Module, you may use Style W (2-wire) or Style X (4-wire) notification circuits to connect appliances. You may also use Style Y (2-wire) or Style Z (4-wire) circuits. This flexibility allows the use of one module in a variety of applications. 866 DESCRIPTION The 866 Notification Module provides one 5 Amp Style W notification circuit for supervising UL listed, polarized notification devices such as bells, strobes, and horns. The 866 is compatible with DMP Command Processor panels. MULTIPLE 866 MODULES You may install up to 25 Model 866 Style W Notification Modules on each XR500 Series XRZOO, XR200-485 panel by using the relay outputs available on the panel. 867 ADDRESSING The 867 has two pairs of rotary switches. One pair sets the module Bell Relay Address. The second pair sets the Supervisory zone address. Having a separate Bell Relay Address allows multiple modules to be activated in groups and yet monitored by individual Supervisory zones. 867 BELL RING STYLE You can specify the bell output cadence on the 867 module by setting the Bell Ring Style jumper for Steady, Pulsed, Temporal Code 3, or California Schools. The 867 can then be activated by the Fire Bell output or by a panel Zone Alarm Output. POWER SUPPLIES 502-12 Provides 2 Amps ® 12 VDC 505-12/LX Provides 5 Amps ® 12 VDC 508 8 Amps ®12or24VDC PANEL COMPATIBILITY 866 and 865 Modules - all DMP Command Processorlm panels. 867 Module - XR500 Series, XR200, and XR200-485, Command Processor Panels. 86 MODuLE SPECIFICATIC Operating Voltage 9.6 to 14.2 VDC from panel Current Draw Standby: 26mA, Maximum: 85mA Maximum Alarm 5 Amps ® up to 30 VDC Circuit Styles One 2-wire Style W or Y or One 4-wire Style X or Z 866 MODULE spEcIF1c:e'•; Operating Voltage 12 VDC Current Draw (from panel) Standby: 45mA, Maximum: 75mA Contact Ratings Alarm 5 Amps at 24 VDC resistive Trouble - 2 Amps at 30 VDC.resistive _____ Digital Mnito.4ng Your Source for Cellular SOlutions The switch is on to cellular for many reasons. In isolated locations, cellular may be the best primary communications path option. Where land lines could go down, cellular provides a reliable backup path. In critical installations where you need to eliminate the risk of cut phone or network lines, cellular is the solution. Whatever your need. DMP has the technology to create reliable panel-to-central station digital cellular communications. Direct cellular communication enables a direct path for alarm signals from the panel to the monitoring station Uses digital cellular GSM/GPRS. CDMA. or HSPA+ data networks in the US and Canada Transmits email and SMS status messages to multiple recipients XR550 and 263H HSPA+ Shown with )Cl30 and 263C CDMA Shown with 383 383 Rubberduck Antenna. Rubberduck Antenna. (Not to scale) DIGITAL CELLULAR COMMUNICATORS GSM, CDMA & HSPA+ SYSTEM FEATURES Modular add-on to XI or XR Series Panels Plug-and-play installation and activation of add-on communication modules Power from panel or separate power supply, with low current draw for long standby battery life Fully supervised to ensure the health of communication DMP Adaptive TechnologyTM switches communication paths while maintaining supervision if the current path becomes unavailable on the XR SeriesTM panels Direct reporting to any DMP Central Station receiver with no Check signal strength indication at the keypad MyAccessTM Messaging features, including text message alerts from the panel, and ability to send commands to the panel via text messages Supports the DMP App XR500E/XR550E provides privacy for your data with DMP encryption technology XR100FC/XR500FC and 463G/463C have FDNY approval for network or cell primary communication relaying or intermediary retransmission of alarm signals - ---, Can be equipped with local or remote antenna PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path. providing installation flexibility and economical options of digital cellular communication. For commercial fire applications, the 46361463C can be used as a stand-alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Or. use your cellular communicator as a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut or compromised. The battery backup provides continued communications even when power is lost. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones. Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGYTM If the primary communication path is compromised or becomes unavailable, Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The checkin frequency and programming for a backup path adapt to the checkin programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel's processor over the GSM/GPRS. CDMA, or HSPA+ wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP Central Station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom Cellular Service from DMP. you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel via an expansion card, the unit is ready to use the SecureCom service. After installing the panel or card, activate the unit via Remote LinkTM. After programming the panel Remote Link recommends the optimum data plan based on the level of security, desired communication path configuration, and specific programming for the account. REMOTE CONTROL VIA MY ACCESSTM: SMS MESSAGING DMP MyAccess lets users send commands via text messages to their panel. Residential and smaller commercial users can now remotely control their systems, including the ability to arm /disarm, control outputs, retrieve system status, and perform automation functions. Each command received by the panel is acknowledged back to the user via return SMS Message. Use any model of cell phone for MyAccess Messaging. REMOTE CONTROL VIA DMP APP The App provides Appte© Phone and iPad owners, as well as Android users, with the ability to access a number of system functions remotely via cellular connection. As a dealer, the App provides the opportunity to load a company logo into the App. For both residential and commercial system owners, the attractive interface provides fast, easy access to the most commonly used system functions. APP CAPABILITIES 'At a glance, check system status including programmed areas. 'Armor disarm the system in an instant Select from the Home/Sleep/Away arming options for home systems. Select from the All/Perimeter arming options for office systems Select from Area Arming Options 'Tap any programmed outputs to turn them on or off. Adjust lighting/thermostat/locks Video capability - up to six cameras, remote viewing. XTL SERIES Both the XTL (GSM) and XTLC (CDMA) are available with on-board cellular which allows for MyAccessTM Messaging Email! SMS message commands to be sent directly to the panel. It is also available with on- board network or WiFi allowing for mobile App Control. This powerful burglary, residential fire. and door access panel provides cellular communication with built-in two-way wireless. CELLULAR COMMUNICATOR For existing XT&XR15O IXR350 IXR550Series panels not originally configured with cellular communications, the 263 Series expansion cards let you add cellular capabilities. The 2636/263C/263H allows alarm messages to be communicated to an SS-1 R or SCS-VR Receiver over their respective GSM. CDMA. or HSPA+ networks. It provides a fully supervised alarm communication path over the network. The 26361263C1263H is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply or battery back-up is needed . Plug-and-play installation makes upgrading your panel quick and easy, and provides all the features and benefits of an XT Series panel originally configured with cellular functionality. The 2636/263H include a SIM card. The 263C does not include a SIM card and is activated with the MElD number. All modules are ready for activation with SecureCom Wireless. COMMUNICATOR XR100/XR500 Series panel users can plug in the 4636/463C expansion card to quickly and easily incorporate cellular communications. In the panel enclosure, it requires no additional enclosures, power supplies. batteries, cabling or conduit connections - simplicity available only from DMP. It can be equipped with local antenna that attaches to the paneL or where necessary for improved signal strength a remote SMA antenna can be used, offering more installation flexibility. The 46361463C draws half the current of other comparable units. With the long standby battery life of the system batteries, the 4636 can continue to provide a communications link for up to 80 hours during a power failure with appropriate standby batteries. The 4636 digital cellular communicator includes a SIM card. The 463C does not include a SIM card and is activated with the MElD number. Both modules are ready for activation with SecureCom Wireless. 464-263H/464-263C DIGITAL.... CELLULAR COMMUNICATOR The 464-263H or462-263Ccellular modules can be plugged onto the XR100/XR500 panel boards to add cellular communications inside the panel enclosure. It requires no additional enclosures, power supplies. batteries, cabling or conduit connections. They can be equipped with a local or remote antenna. A 381 cable is required for the XRI50 I XR350 I XR550 Series. The XR500FC Series Fire panels used with the 4636 or 463C Digital Cellular Communicator has earned the UL 864 listing when used as the primary path (no backup required) for commercial fire installations per NFPA 72. The check-in and fail time settings are programmed for five minutes. When used as the backup path, the 4636/463C provides the security of a communication link that continues to function, even when land lines are cut or compromised. These interfaces work on digital cellular GSM/GPRS and CDMA data networks over a variety of carriers in the USA and Canada. TECHNOLOGY OPTIONS Selecting the right Cellular Communicator Built-in GSM Built-in COMA 2636 263C/263H 4636/463C 464-263C/464-263H XT30IXT50 X X XR100 Series X X XR500 Series X X XTL Series X X XR150 1 XR350 I XR550 Series X ORDERING INFORMATION 2636 GSM/GPRS Digital Cellular Communicator (AT&T. I-Mobile. (2636CAN - Rogers)) 4636 GSM/GPRS Digital Cellular Communicator (AT&T. T-Mobile. (46GCAN - Rogers)) 263C CDMA Cellular Communicator (Verizon) 463C CDMA Cellular Communicator (Verizon) 263H HSPA+ Cellular Communicator (AT&T. 1-Mobile. (263HCAN - Rogers)) 464-263C CDMA Cellular Communicator (Verizon) 464-263H HSPA+ Cellular Communicator (AT&T. 1-Mobile) LISTINGS AND APPROVALS 263C/2636/263H/463C/4636 California State Fire Marshal (CSFM) 263C/463C/464-263C FCC ID: MIVCNNO301 Industry Canada: 4160ACNN0301 2636/463G FCC ID: MIVGSM0308 Industry Canada: 4160A65M0308 263G/263H/4636 PTCRB Certified 263H/464-263H FCC ID: RI7HE91ONA Industry Canada: 5131AHE91ONA 463C/4636 New York City (FDNY COA #6123) Underwriters Laboratories (UL) Listed 263G ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 1635 Digital Burglar ANSI/UL 1610 Central Station Burglar Alarm Units 263C/263H ANSI/UL 294 Access Control System Units ANSI/UL 636 Holdup Alarms Units and Systems Accessory ANSI/UL 985 Household Fire Warning ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglary ANSI/UL 1635 Digital Burglar 4636/463C ANSI/UL 365 Police Station Connect Burglar Alarm Systems ANSI/UL 985 Household Fire Warning System Units ANSI/UL 1023 Household Burglar Alarm System Units ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units ANSI/UL 864 Control Units for Fire-Protective Signaling Systems Underwriters Laboratories Canada (ULC) Listed 463G ULC Subject-C1023 Household Burglar ULC/0RD-C1 076 Proprietary Burglar ULC S304 Central Station Burglar ULC S545 Household Fire ULC 5559-04 Equipment for Fire Signal Receiving Centers and Systems For additional information, access www.dmp.com and select Compliance. C" I-. I! j 11 c. 9MAN111 .1.I —-- 263G/263C/263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw (2636) Standby 18mA Alarm 18mA Current Draw (2630 Standby 13mA Alarm 13mA Current Draw (263H) Standby 24mA Alarm 28mA 463G/463C SPECIFICATIONS Primary Power 12 VDC from panel Current Draw (4636) Standby 22mA Alarm 45mA Current Draw (4630 Standby 22mA Alarm 22mA 464-263C/464-263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw Standby 36mA Alarm 36mA 263G COMPATIBILITY XTSeriesTM Panels 263C/2631H COMPATIBILITY XT Version 112 or higher & XR1 50 I XR350 I XR550 Series Panels (A 381 cable is required for the XR150 I XR350 XR550 Series.) 463G/463C COMPATIBILITY DMP XR1 00/XR500 Series panels using Software Version 202 or higher 464-263C/464-263H COMPATIBILITY DMP XR100/XR500 Series panels using Software Version 212 or higher ACCESSORIES 381-1 10 Coax Extension 381-2 18 Coax Extension 381-12 12 Coax Extension 381-25 25 Coax Extension 383 Rubber Duck Antenna 386 Wail Mount Antenna Bracket 387-1 3dB Fiberglass Antenna w/bracket 387-2 2dB Attack Enclosure Antenna 387-3 3dB MEG Antenna 387-4 4 SMA to N Extension Cable 387-8 8 SMA to N Extension Cable 387-25 SMA TO N CABLE. 25F1 LMR1 95 387-50 SMATO N CABLE. 50FT. LMR195 SECURflT SIGNALUIG NYC MEA 0 LISTED i4 V ,L A- -, .-- - - - ? 4G - The most affordable codeless arming and disarming available - with a slim new look! 7000 Series Thin Line LCD Keypads offer high-quality, cost-effective security control in a stylish, sleek new design. Visual and audible alarm notification Silence alarm while system remains armed Optional integrated proximity reader Four optional on-board fully programmable zones Retrofit to any DMP panel Enhanced Options 7063 and 7073 keypad proximity readers accept DMP 1300 Series proximity credentials. THINLINETM LCD KEYPADS 7060IjJ707017073 FEATURES Attractive Thinline keypad housing available in several • View system events/user activity through keypad display colors • AC power and Armed LED Large, 32-character, Liquid Crystal Display (LCD) • Suitable for access, burglary, and fire applications Custom 16-character home or business name • Distinct fire, burglary, zone monitor, and prewarn tones Keypad and logo backlighting turns Red in alarm conditions • Displays time of day, armed zones, and armed areas User-adjustable brightness, tone, and volume controls • Optional backboxes for conduit or watt-mount applications Supports Cancel/Verify' feature • Unique silence feature allows the user to silence alarm Built-in diagnostics for ease of service belts and stilt keep the system armed Simple harness connection to 4-wire keypad bus • Compatible with all DMP panels Connect devices directly to keypad zones - - - --a - IEY UAJS - VERSATILE SUPERVISED AND UNSUPERVISED OPERATION When programmed for supervised operation, the keypad occupies its own unique device address on the keypad data bus. Unsupervised operation allows you to install an unlimited number of keypads set to the same device address. Increasing the number of keypads allows maximum system operating flexibility. USER-FRIENDLY MENU FUNCTIONS The User Menu allows you to quickly browse through menu options. Disarming and Arming functions are fast and easy. Any function allowed by the user authority level is simply accessed through the keypad, such as silencing alarms, resetting sensors, or displaying events. 2-BUTTON PANIC KEYS The top row of keys can be used as 2-button panic keys. The user simply presses and holds two of the keys simultaneously to send either a panic, non-medical emergency, or fire report to the Central Station. Top Row Select Keys -- — 41 .;:\. Police Emergency Fire Label shows Icons only Panic Key Labels CANCELIVERIFY In a Home/Sleep/Away or AlL/Perimeter system, you can CANCEL a burglary alarm or VERIFY that a valid burglar alarm has occurred. Selecting VERIFY manually verifies the alarm and sends an alarm verification message to the central station. KEYPAD SHORTCUT KEYS Keypad shortcut keys are provided to simplify operation and allow the user to more quickly arm, check in, monitor, exit, or reset the system. One-button arming creates the simplest keypad available. Use the one-button shortcut keys for common functions, or use the ATM style menu for advanced functions, whichever method meets the user's needs or Level of expertise with the system. END-USER CONTROL Each of the Thinline Series keypads provides a simple User Options menu for adjusting brightness, speaker tone, and volume. VALUABLE VISUAL ALARM INDICATOR In a normal state, both the keypad and logo backlighting remain Green. However, during an alarm state, the keypad and logo turn Red. The change in color allows persons on-site to instantly recognize an alarm condition. Red Backlighting DISTINCT SOUND PATTERNS The keypads also provide distinct sound patterns for fire, burglary, zone monitor, and prewarn that can help users identify the event occurring on their system. RETROFIT ANY EXISTING DMP SYSTEM Retrofitting is quick and easy. Thinline keypads have the same footprint as existing DMP keypads and mount in currently installed backboxes. Thinline Series keypads require no special modules or panel upgrades. You can provide a new look and greater functionality to an existing system at just a fraction of the cost of all new equipment. MULTIPLE-KEYPAD SAVINGS Install multiple keypads on the same wire run. Compatibility and cost savings make the Thinline Series an asset in every installation. OPTIONS The Thinline Series keypads also provide Keypad Options and Keypad Diagnostics menus available only to system installers and service technicians. Enter Keypad Options to set the keypad address and change the default keypad message. Test the keypad operation at any time without disabling the system. The diagnostics program tests the LCD segments and backlighting, each of the 16 keyboard keys, and the four zones on the 7070 and 7073 keypads. fill III li J , •4' Green Backlighting T.: UNIVERSAL PROGRAMMING TOOL System installation and programming can be achieved without carrying around or purchasing expensive external programmers since panel and add-on module programming is integrated into DMP Keypads. Individually program panels, an iCOM Network Alarm Router, iCOMsL Network Alarm Communicator, and other programmable add-on modules directly from the keypad. 707017073 FOUR EXPANSION ZONES Zone expansion is available right on the keypad where you need it the most. The four expansion zones on the 7070 and 7073 models are fully programmable Class B protection zones that can be used for a variety of fire, burglary, and access control applications. ZONE TYPE SELECTION Keypad zones can be programmed using the same zone types available on the panel. Select supervised, unsupervised, night, fire, panic, exit, and emergency operation depending on the user requirements. ZONE DEVICE CHOICES Connect PIRs, door and window contacts, pull stations, sprinkler tamper switches, and silent panic buttons. Plan the installation to afford the best coverage while eliminating potential problems associated with multiple wire runs. 706317073 CODELESS ARMING AND DISARMING The innovative 7063 and 7073 Thiniine keypads contain an on-board DMP proximity reader that allows users to simply present their proximity credentials to the keypad to gain access to a protected area. 7073 SOFT-SHUNT® MOMENTARY BYPASS To provide an entry and exit window on systems with 24-hour perimeter protection, DMP offers the Soft-Shunt® feature. Soft-Shunt allows the user enough time to enter or exit the area. If the door remains open when the timer expires, a zone open/short is sent to the panel for the keypad Zone 2. REQUEST-TO-EXIT (REX) To enable easy user exit from an area, connect a motion sensing or mechanical device to Zone 3 on the keypad. As the user trips the zone, the keypad activates the door strike allowing the user to exit the area without presenting a card or entering a user code. PRIVATE LABELING DMP offers dealers the option to present their company logo on the 7000 Series keypads. The Logo displays on the rubber logo insert and replaces the DMP logo. The backlighted logo glows Green during normal operation and turns Red in an alarm state. Logo Location Place Your Logo Here -- KEYPAD MODEL FEATURES Model 2-Button Panic Red in Alarm 4-Zones Internal Prox Reader Wiegand Input Internal Form C Door Strike Relay 7060 X X 7063 X X X 7070 X X X 7073 X X X X X Digital Monitoring Products t'.1E"' IE VANILE30S KEYPAD ACCESSORIES KEYPAD ORDERING INFORMATION ackboxes The Thinline Series keypads are available in White, Ivory or 695 Keypad Conduit Backbox Black to complement any decor. Select from the following 696 Keypad Backbox ptions: eypad Wiring Harness 300 4-wire harness 300-5 5-wire harness 060W 300-12 12-wire harness 063 W 300-512 12-wire harness, 5 ft. long 070W roximity Credentials 073 W .. 1306 Prox PatchIm 1306PW Prox Patch' 1326 ProxCard Il® Card 1346 ProxKey 110 Access Device 1351 ProxPass® 060 1386 ISOProx Il® Card 063 xternal Proximity Readers 070 PP-6005B ProxPoint Plus Proximity Reader 073 MP-5365 MiniProx1 Proximity Reader PR-5455 ProxPro II Proximity Reader MX-5375 MaxiProx Proximity Reader TL-5395 ThinLine II Proximity Reader 7060-B 7063-B 7070-B 7073-B SPECIFICATIONS LISTINGS AND APPROVALS Operating Voltage 12 VDC California State Fire Marshall (CSFM) Dimensions T'Wx 5.25" HxO.5" D FCC Part 15 ID: CCKPCO086 Display Type LCD Industry Canada ID: 5251A-PC0086 Colors White, Ivory, Black New York City (MEA) COMPATIBILITY Underwriters Laboratory (UL) listed 7000 Thinline Series keypads are compatible ANSI/UL 294 Access Control System Units with all DMP panels. Thinhne keypads are not ANSI/UL 365 Police Connected Burglar available in a Fire Keypad Variation. ANSI/UL 609 Local Burglar CURRENT DRAW ANSI/UL 1023 Household Burglar . 7060 Standby 72mA ANSI/UL 1076 Proprietary Burglar Alarm 87mA ANSI/UL 1610 Central Station Burglar 7063 Standby 85rnA ANSI/ UL 985 Household Fire Warning Alarm 100rn.4 ANSI/UI 864 Fire Protective Signaling 9th Edition 7070 Standby, 72mA + 1.6mA per active zone (7070,7073) 3 = Alarm 87mA + 2mA per active zone or additional information, access www.dmp.com and select 7.073 Standby 85mA + 1.6mA per active zone ompliance. B Alarm • lOOmA + 2mA per active zone 07 2500 North Partnership Boulevard Digital Monitoring Prod"It* Springfield, Missouri 65803 8877 * IF USTED Simple operation provides instant alarm The 850 Series Fire Alarm Pull stations offer quick and simple operation that's economical and reliable. Available in single or dual-action manual pulls SPST contacts and terminal strip connections Gold-plated contacts to avoid the risk of corrosion FIRE ALARM :iuj I -. —.--J.... FEATURES Approvals: UL and CSFM • Mounts on standard single-gang box Americans with Disabilities Act (ADA) compliant a Optional surface and weatherproof backboxes available Die-cast metal construction • High-gloss red enamel finish Reset key e Scored acrylic breakrod DESCRIPTION MOUNTING OPTIONS BSOD OPERATION The DMP 850 Series Fire Alarm Pull A variety of mounting options are On the Model 850D Dual Action Pull Station is a high quality, die-cast available for the 850 series. It can be Station, the push bar rotates inward metal manual pull station available flush mounted to a standard single gang allowing the PULL handle to be grasped in either single-action or dual-action switch box or surface mounted in two in a one handed motion. configurations with SPST contacts and optional configurations. The Model terminal strip connections. The normally 850-SB Interior Surface Backbox or the ADDRESSABLE ZONE open contact, which closes when the pull Model 850-WP Weatherproof Backbox To create an addressable reporting zone station is activated, is rated for 1 Amp® both allow conduit connection to the for the 850 Series, install a Model 711 30 VDC. The contacts are gold-plated to 850 Series Pull Stations. Zone Expansion module. avoid corrosion risks. Scored acrylic breakrods are used with the 850 series. COMPLIANCE The 850 series has been tested by UL for compliance to the latest requirements of the ADA. 850S OPERATION The Model 850S Single Action Pull Station is operated by pulling the handle on the front of the station as far down as it goes. When the handle locks into place it is easily visible from up to 50 feet. Reset the handle by opening the station with the supplied key, placing the handle in the normal upright position and re-Locking the station. PULL Screw Terminals A± To next To Fire Alarm - device or Control Panel - - EOL resistor Model 850 Wiring Diagram ORDERING INFORMATION Ito A 850S Single-action pull station I V 0 - 850D Dual-action pull station 850-SB Interior surface sheetmetal backbox 850-WP Weatherproof surface die-cast backbox 850-AR Scored acrylic breakrods (1 dozen) 850S/711 Single-action pull station w/addressable module 850D/711 Dual-action pull station w/addressable module Note: All models are supplied with one scored acrylic breakrod and one key. 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 OI PCIFKATQNS Switch Rating 1 Amp ® 30 VDC Dimensions 4.75" H x 325 W x 2.25'.' D Color Red w/raised white Letters, white PULL handle wiraised red letters COMPATIBILITY The 850 Series Fire Pull Station is compatible with all DMP Command Processors. System Sensor's j3" series smoke detectors repres significant advancement in conventional detecti Photoelectric Smoke Detectors The j3 family is founded on three principles: instaL SYSTEM $ SENSOR ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & <~> 0. MEA MSFM LISTED APPROVED approved approved 5911 3011446 7272-1209210 290-01-€ 2093 Installation ease. The il line redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, P heads plug in to the base with a simple Stop-Drop 'N Lock' action. Intelligence. il detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. Two-wire P detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the P protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent per-foot-obscuration. Instant inspection.The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on two-wire P detectors. This feature verifies Inc initiating loop wiring by providing LED status indication at each detector. Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4W1-B) with thermal sensor rated at 135°F (572°C).The detector shall include a mounting base for mounting to 31h-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 1 2124V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 pA 4-wire: rVa Alarm Contact Ratings 2-wire: r'a; 4-wire: 05 A @ 30V AC/DC Physical Specifications Dimensions (including base) 53 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 o (178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-I 20°F (0°C-49°C); 2WT-B and 4W7-B: 32°F-100°F (0°C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135F (57.2C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft. nominal Input Terminals 14-22 AWG Mounting ILED1Tr3 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LEO Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity oil Blink every 5 seconds Freeze trouble of Blink every 10 seconds Alarm Ulf Solid Ordering Information model 2W-B Thermal No Yili,r. 2-wire AlarmCurrent 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ IN 23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V, 23mA @ 24V Accessories 2W-MOD2 SENS-RDR 2-wire loop test / maintenance module RT Sensitivity reader A77-AB2 Removal / replacement tool Rtrnflradaptei brarkei,6.f in. (16Th:m) diarrw'iir 5EI'J5OR U2006 kw- Sm- 3825 Ohio Avenue St Charles IL 60174 Phone: 800-SENSOR2 Fax: 630-377-6495 A05-031 F,006 - liftil COOPER Notification E;XC7ED'&7V-_ I Finally, Design and Safety Meet... Description: The Wheelock® ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock5 ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now, in 1 appliance - Save up to 14% cost of instalIation Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points 6.0 Multiple Voltages 3 Audible Settings 90, 95, 99 dB f-f 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 UA111=," Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock5 Sync Modules or panels with built-in Wh6elockO Patented Sync Protocol -Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VflMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range * Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and.WARNINGS are identified by the symbol k. All warnings are 'printed in boIdcapltaI letters ,'- WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY, BEFORE USING, SPECIFYING' OR APPLYING THIS PRODUCTVISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPERNOTIFICATION FRTHE CURRENT INSTALIATION INSTRUCTIONS.-FAILURE TO COMPLY-WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COUI.DRESULT IN JMROPER APPLICATION, INSTALI.IATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND,, SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.,, General Notes: General Notes. Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range' All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. ' -e Series Exceder Strobe products are Listed under UL Standards 1971 and 454 for indoor use seth a temperature range of 32'F to 120'F (O 'C to 491C) and maximum humidity of 931/,(± 27,) UL464 (851/ UL 1971/. Series Exceder horns are under UL Standard 454 for audible signal appfances (Indoor use only). ,... ., + - , trobe Ratings per UL Standard 1971 iJ Max LCurrent' I- ________________ 24 VDC /24FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 J ? 95 110 115 f 135 150 177 185 15 15/75 Range VDC ST 1 8.0-33.0 10.05710.07010.085 0.13510.1631 0.182 F J 0.205 ,4 0.253 0.110 [91401 STC 1 8.0-33.0 10.061 _____ 0.085 0.103 0.135 0.163 0.110 Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC UJ Max Current' 11I51sIiI:1L 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 1185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 , 0.282 0.125 0.159 HSC 8.0-33.0 i 0.082 i 0.102 i 0.141 i 0.148i O.176J4. 0.197 ' 0.242 0.282 UL Current* at 95 dBA I 24 VDC ' 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 1 115 1135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.1 39 0.,1 63 a18610.230 0.272 022 053 HSC 8.0-33.0 10.073 0.087 0.128 0.139 0.163 E" I 0.186t " 0.230 0.272 0.122 UJ• Current* .1I5lsr.l:YL I 24 VDC ' 12 VDC Model Regulated Voltage 15 15/75 30 60 110 115 1135 150 177 5 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 :. 0.136 0.157 0.184 j0.226 0.267 0.120 0.148 HSC 80330 00650084 0.120 0.136 0.157 0184J0226I0267 0120w Horn Ratings per UL 464 Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 1 8.0-17.5 10.04710.02610.017 * UL max current rating IS the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units) For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units) For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units) For unfiltered ratings see installation instructions - Sync WI SM, Strobe Mounting Model Candela DSM or 12124 VDC Options I I • PS-6 & PS-8 I HSR 15/1575/30175/95/110/135/185 X X .. UMB** • S 1-ISW 15/1575/30/75/95/110/135/185 X X UMB HSRC 15/30/60175I95/115/150/177 X X - UMB • S • RSWC II 15/30160175/9511151150/177 X X UMB UMB STR 15/1575/30/75/95/110/135/185 X X S1W 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** • STWC 15/30/60175/95/115/150/177 X X UMB** HNR • X X UMB** X UMB** S HNW ,HNRC X X UMB** HNWC X X UMB** *12 VDC models feature 15 & 15/75 settings **UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications I The notification appliances shall be Wheelock® ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and I-IN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault-condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC LI WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 11/09 Cooper Notification is Wheelock' IMEDCIJ SAFEPATH WAVEITS11 COOER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:0135 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 2631-1: Cellular Communicator 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X. 1100XH: RF Wireless Receiver 1100R: Wireless Repeater 1103: Wireless Transmitter 1135: Wireless Siren 12-11-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed Sj\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: December 26, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. 12-11-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: December 26, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1157:0112 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tsheltondmp.com DESIGN: Models 850D (key lock, push bar) and 850S (key lock, no push bar) noncoded manual pull stations. Suitable for outdoor use when installed with Model 850-WP back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *Rev 06-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4W1-B employ a thermistor type heat sensor (135F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 T4, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover©cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '- NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall): 15,15/75, 30, 75, 95, 110,135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VI' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division