HomeMy WebLinkAbout3410 VIA MERCATO; ; FS140032; Permit4/15/24, 3:28 PM FS140032 Permit Data City of Carlsbad Fixed Systems Permit Job Address: .3410 VIA MERCATO Permit Type: FIXSYS Parcel No: Lot #: 0 Reference No.: Permit No: FS140032 Status: ISSUED Applied 10/30/2014 Approved: 11/12/2014 Issued: 11/12/2014 PC #: Inspector: Project Title: NOODLES &CO #577 R102 RESTAURANT FIRE SUPPRESSION SYSTEM EXISTING TENANT NEW FIRE SYSTEM NEW COOKING HOOD TYPE I Applicant: Owner: AZTEC FIRE & SAFETY 8108 COMMERCIAL ST LA MESA, CA 619-464-5625 Fees ($) Add'I Fees ($) . Total ($) Balance ($) 232 0 232 0 about:blank 1/1 10.I APJSUL]. u I co Ea ansulmimi sub noappli.pdf 1 - FSI 40032 014 8:46:15AM IN 0 SECTION I - GENERAL INFORMATION UL EX. 3470 ULCCEx747 Page 1-1 4-1-06 REV. 4 DESIGN AND APPLICATION The ANSUL R-102 Restaurant Fire Suppression System is designed to provide fire protection for restaurant cooking appli- ances, hoods, and ducts. It is a pre-engineered group of mechan- ical and electrical components for installation by an authorized ANSUL distributor. The basic system consists of an ANSUL AUTOMAN regulated release assembly which includes a regulat- ed release mechanism and a liquid agent storage tank housed within a single enclosure. Nozzles, detectors, cartridges, liquid agent, fusible links, pulley tees, and pulley elbows are supplied in separate packages in the quantities needed for each fire suppres- sion system arrangement. The system provides automatic actuation; or it can be actuated manually through a remote manual pull station. The system is also capable of shutting down appliances at system actuation. For appliance shutdown requirements, refer to the current version of NFPA 17A, "Standard For Wet Chemical Extinguishing Systems' and NFPA 96, "Standard For Ventilation Control and Fire Protection of Commercial Cooking Operations." Additional equipment includes: remote manual pull station, mechanical and electrical gas valves, pressure switches, and elec- trical switches for automatic equipment and gas line shut-off. Accessories can be added, such as alarms, warning lights, etc., to installations where required. The R-102 system suppresses fire by spraying the plenum area, the filters, cooking surfaces, and the exhaust duct system with a predetermined flow rate of ANSULEX Low pH Liquid Fire Suppressant. When the liquid agent is discharged onto a cooking appliance fire, it cools the grease surface, and reacts with the hot grease (saponification) forming a layer of soap-like foam on the surface of the fat. This layer acts as insulation between the hot grease and the atmosphere, thus helping to prevent the escape of combustible vapors. Exhaust fans in the ventilating system should be left on. The forced draft of these fans assists the movement of the liquid agent through the ventilating system, thus aiding in the fire suppression process. These fans also provide a cooling effect in the plenum and duct after the fire suppression system has been discharged. The system is UL listed with or without fan operation. Make up or supply air fans, integral to the exhaust hood(s) being protected, shall be shut down upon system actuation. Along with the fire suppression system, the total system design must include hand portable fire extinguisher(s) located within the cooking/restaurant area that can be used to manually suppress a fire that may be burning in an unprotected area. Refer to NFPA 10, "Standard For Portable Fire Extinguisher," for additional information. UL LISTING The R-102 Restaurant Fire Suppression System has been tested and is listed by Underwriters Laboratories, Inc. as a pro-engi- neered system. The system is in compliance with UL Test Standard 300. These tests require extinguishment of fires which are initiated in deep fat fryers, ranges, griddles, char-broilers, woks, upright broilers, chain-broilers, filters, plenum chambers, hoods, and ducts after pre-loading each appliance with a pre- scribed amount of cooking grease. Each fire is allowed to progress to maximum intensity before the fire suppression system is actuated. DEFINITION OF TERMS Actuation Gas Line: Piping from the ANSUL AUTOMAN Regulated Release Assembly which supplies nitrogen or carbon dioxide to the Regulated Actuator Assembly for multiple-tank sys- tem actuation. Agent Tank: A pressure vessel containing the liquid agent. ANSUL AUTOMAN Regulated Release Assembly (Electrical): An assembly which contains the regulated release mechanism, agent tank (ordered separately), expellant gas hose, solenoid, and electric switch within a metal enclosure. The enclosure contains knockouts to facilitate component hookups. ANSUL AUTOMAN Regulated Release Assembly (Mechani- cal): An assembly which contains the regulated release mecha- nism, agent tank (ordered separately), and expellant gas hose within a metal enclosure. The enclosure contains knockouts to facilitate component hookups. Authority Having Jurisdiction: The "authority having jurisdiction" is the organization, office, or individual responsible for "approving" equipment, an installation, or a procedure. The phrase "Authority Having Jurisdiction" is used in a broad manner since jurisdictions and "approval" agencies vary as do their responsibilities. Where public safety is primary, the "authority having jurisdiction" may be a federal, state, local, or other regional department or individual such as a fire chief, fire marshal, chief of a fire prevention bureau, labor department, health department, building official, electrical inspector, or others having statutory authority. For insurance pur- poses, an insurance company representative may be the "author- ity having jurisdiction." In many circumstances the property owner or his designated agent assumes the role of the "authority having jurisdiction;" at government installations, the commanding officer or departmental official may be the "authority having jurisdiction." Blow-Off Cap: A cap which covers the end of the nozzle tip and prevents grease from plugging the nozzle orifice. Branch Line: The agent distribution piping which extends from the supply line to the nozzle(s). Bursting Disc: A disc installed in the tank adaptor which elimi- nates the siphoning of the agent up the pipe during extreme tem- perature variations. Cartridge: A sealed, steel pressure vessel containing nitrogen or carbon dioxide gas used to pressurize the agent tank. Cooking Appliance: Includes fryers, griddles, ranges, upright broilers, chain broilers, natural charcoal broilers, or char-broilers (electric, lava rock, gas-radiant, or mesquite). Cooking Area: Cooking area is defined as the maximum surface that requires protection. Each type of appliance has a defined cooking area. For example, the maximum cooking area is the fry- pot for a fryer without a dripboard and the maximum cooking area is the combined frypot and dripboard for a fryer with a dripboard. Conduit Offset Assembly: A pre-formed piece of conduit which can be installed between the ANSUL regulated release and the conduit to allow the wire rope for the detection, gas valve and remote manual pull station to be installed in a more convenient manner. Depth: When referring to depth as a linear dimension, it is the horizontal dimension measured from front to back of the appliance or plenum. ansul mimi sub no appll.pdf 2 1/10/2014 8:47.06 AM . EEH SECTION I - GENERAL INFORMATION UL EX. 3470 ULCCEx747 Page 1-2 REV. 5 4-1-06 DEFINITION OF TERMS (Continued) Detector: A device which includes the detector bracket, detector linkage, and fusible link used for automatic operation of the fire suppression system. Detector Linkage: A device used to support the fusible link. Distribution Piping: Piping which delivers the extinguishing agent from the tank to each discharge nozzle. See also Supply or Branch lines. Ducts (or Duct System): A continuous passageway for the trans- mission of air and vapors which, in addition to the containment components themselves, may include duct fittings, plenums, and/or other items or air handling equipment Electrostatic Precipitator: A device used to aid in the cleaning of the exhaust air. This device is normally installed at or near the base of the ventilation duct. Expellant Gas Line: Piping and/or hose which supplies the nitro- gen or carbon dioxide gas from the regulated release assembly/ regulated actuator assembly to each agent tank. Flow Number: Term used in system design to describe the flow capacity of each nozzle used to determine the quantity of tanks needed to cover a certain group of hazards. Fusible Links: A form of fixed temperature heat detecting device employed to restrain the operation of a mechanical control until its designed temperature is reached. Gas Valve: A device used to shut off the gas supply to the cook- ing equipment when the system is actuated. Gas Valve Air Cylinder: An air cylinder, located in the release mechanism, which operates pneumatically to mechanically unlatch a mechanical gas valve actuator, causing the gas valve to close upon system actuation. High Proximity: Indicates a distance (vertically) between the noz- zle tip and the surface of the appliance being protected. Hood: A device provided for cooking appliances to direct and cap- ture grease-laden vapors and exhaust gases. It shall be construct- ed in a manner which meets the requirements of NFPA 96. Liquid Agent: A potassium-based solution used for the knock- down and suppression of fire. Low Proximity: Indicates a distance (vertically) between the noz- zle tip and the surface of the appliance being protected. Maximum Length of Cooking Appliance: The maximum dimen- sion, on any side, which may be protected by one nozzle. Maximum Piping: Specified length of piping and number of fit- tings which must not be exceeded for each system. Medium Proximity: Indicates a distance (vertically) between the nozzle tip and the surface of the appliance being protected. Minimum Piping: Minimum length of distribution piping required between the agent tank outlet and any nozzle protecting a griddle, range, or fryer. Nozzle: A device designed to deliver the liquid agent with a spe- cific flow rate and stream pattern. Overlapping Protection: When discharge nozzles are spaced equally apart over one or more appliances requiring protection. Nozzles used in this manner provide area protection of eligible appliances within the protected area. Two types of overlapping pro- tection is available: full hood continuous protection and group pro- tection. Overlapping protection is in addition to appliance specific coverages. Plenum: The space enclosed by the filters and the portion of the hood above the filters. Pre-engineered System: NFPA 17A defines a pre-engineered system as one which has "...predetermined flow rates, nozzle pressures, and quantities of liquid agent' The A-i 02 system, as prescribed by UL (Underwriter's Laboratories), has specific pipe sizes, maximum and minimum pipe lengths and numbers of fit- tings, and number and types of nozzles. The hazards protected by this system are also specifically limited as to type and size by UL based upon actual fire tests. All limitations on hazards that can be protected and piping and nozzle configurations are contained in the R-102 installation and maintenance manual which is part of the UL listing. Pulley Elbow: A device used to change the direction of the wire rope which runs between: the regulated release mechanism and the detectors, the regulated release mechanism and the mechan- ical gas valve, and/or the regulated release mechanism and the remote manual pull station. Pulley Tee: A device used to change the direction of two wire ropes which run from a regulated release or a regulated actuator to two remote manual pull stations, or from two regulated releases or regulated actuators to a single mechanical gas valve or from one regulated release or regulated actuator to two gas valves. Regulated Actuator Assembly: An assembly which contains the regulator, pneumatic actuator, agent tank, and expellant gas hose within a metal enclosure. This assembly is used to pressurize addi- tional agent tanks in a multiple tank system. Regulated Release Mechanism: An enclosed device within the ANSUL AUTOMAN regulated release assembly which releases the expellant gas, activates alarms, and/or shuts off other devices when signaled automatically by a detector or manually with a remote pull station. Regulator: A device used to regulate the pressure from the nitro- gen cartridge into the agent tank(s) when the system is actuated. Remote Manual Pull Station: A device which provides manual actuation of the system from a remote location. Salamander Broiler: A broiler very similar in design to the upright broiler. A salamander broiler is used for general broiling of meats and fish, toasting, and holding/warming foods. Most contain a removable grease drip tray. r Silicone Lubricant: A heat-resistant organic compound used to lubricate 0-rings, rubber and mechanical components. Supply Line: The agent distribution piping which extends from the agent tank outlet and serves as a manifold for the branch lines. Series Detector: Any detector located in-line between the regu- lated release assembly and the terminal detector. Terminal Detector: The last in a series of detectors, or the only detector used in a single-detector system. This detector is thus named because it is at the point at which the wire rope ends, or "terminates." There is only one terminal detector per detection system. Transition: An extension of the hood or canopy which allows for the smooth transmission of gases, air, and vapors between the hood opening and the base of the ventilation duct. Vent Plug: A device used to prevent pressure build-up within the agent. tank or agent distribution lines due to temperature fluctuations. ansul mimi sub no appli.pdf 3 1/10/2014 8:47:58 AM LWA SECTION II— SYSTEM DESCRIPTION UL EX. 3470 ULC CEx747 Page 2-1 3-1-04 REV. 3 TOTAL SYSTEM There are three types of R-102 Restaurant Fire Suppression Systems: Single-tank System Double-tank System Multiple-tank System The type of system required for the particular installation will be determined through the guidelines covered in "System Design:' Additional equipment which may be required to complete the sys- tem design is explained in the "System Components" section. Additional devices covered are: remote manual pull stations, mechanical and electrical gas shut-off valves, electrical switches, and pressure switches. Single-Tank System The R-102 single-tank system is available with a stainless steel enclosure and consists of: 1. ANSUL AUTOMAN Regulated Release Assembly (Electrical or Mechanical) 2. Nitrogen Cartridge and/or Carbon Dioxide Cartridge 3. ANSULEX Low pH Liquid Fire Suppressant Discharge Nozzles Detection Components Additional Devices (As Required) The regulated release assembly contains the regulated release mechanism, agent tank, expellant gas hose for agent tank hookup, and enclosure knockouts to facilitate installing detection system and additional equipment. Refer to "System Components" section for individual component descriptions. Double-Tank System The R-102 double-tank system is available with a stainless steel enclosure and consists of: ANSUL AUTOMAN Regulated Release Assembly (Electrical or Mechanical) Nitrogen Cartridge and/or Carbon Dioxide Cartridge ANSULEX Low pH Liquid Fire Suppressant Enclosure or Bracket Assembly Discharge Nozzles Detection Components Additional Devices (As Required) The regulated release assembly contains the regulated release mechanism, agent tank, expellant gas hose for agent tank hookup, and enclosure knockouts to facilitate installing expellant piping, detection system, and additional equipment. The enclosure or bracket assembly is mounted separately but within the guidelines of the regulated release assembly expellant gas piping requirements to ensure simultaneous actuation of the system. Refer to "System Components" section for individual com- ponent descriptions. FIGURE 2 O134 FIGURE 1 OW133 ansul mimi sub no appli.pdf 4 1/10/2014 8:4837 AM iJDI• e :• •-no SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-43 4-1-06 •REV.5 TANK AND CARTRIDGE REQUIREMENTS Once the hazard analysis is completed and the total nozzle flow numbers are established, the quantity and size of agent tanks and cartridges needed to supply the nozzles with the proper volumes of agent at the proper flow rates can be determined. For cartridges used in the regulated release mechanism, flow capacities, tank quantities and sizes, and regulated release cartridge options are given in the table below. Total Quantity and Regulated Release Flow Size of Cartridge Options Numbers* Tank(s) Nitrogen Carbon Dioxide 1- 5 (1) 1.5 Gallon LT-20-R 101-10 6-11 (1) 3.0 Gallon LT-30-R 101-20 11-16 (1) 1.5 Gallon Double 101-30 (1) 3.0 Gallon 16-22 (2) 3.0 Gallon Double 101 When one or more regulated actuators are used, the following tank and cartridge combinations apply for each regulated actuator: ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS This section contains the guidelines for installing the actuation and expellant gas lines between the regulated release mechanism reg- ulator, each regulated actuator regulator, and each agent tank. These limitations should be considered when selecting the com- ponent mounting locations. Actuation Gas Line— 6 to 8* Tanks Maximum B Tank maximum reflects the utilization of 3 tank regulated actuators. Use only 1/4 in. Schedule 40 black iron, hot-dipped galva- nized, chrome-plated, or stainless steel pipe and fittings. The actuation gas line piping is installed from the regulated release mechanism to each regulated actuator connected within the system. The, total length of the actuation gas line from the regulated release assembly to the regulated actuator assembly(ies) must not exceed 20 ft. (6 m) when using an LT-20-R, an LT-30-R nitrogen cartridge, or a 101-10 or a 101-20 carbon dioxide cartridge. See Figure 80. Regulated Actuator Regulated Actuator Tank(s) Cartridge (1) 1.5 Gallon LT-20-R or 101-10 (1) 3.0 Gallon LT-30-R or 101 -20 (1) 1.5 Gallon and LT-A-101-30 or 101 .30** or 3.0 Gallon double tank 3.0 Gallon LT-A-101-30 or 101-30** or double tank - For exceptions to maximum flow numbers. sac Distribution Piping Requirements for 1.5 gallon - and 3.0 gallon systems in this Section. The 101-30 cartridge can not be used when (2) two 3.0 gallon tanks are maniloided together.) For higher total flow numbers (23 to 110), multiple cartridges and regulated actuators are required as shown in the System Selection Guide in Section IX - Appendix. REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS LINES NOT INCLUDED IN ACTUATIO GAS LINE LENGTH TOTALS TED ACTUATOR ACTUATION GAS LINE WITH AN LT-20-R, LT-30-R. 101 -10 OR 101.20 CARTRIDGE MAXIMUM LENGTH OF 20 FT. (6 m). MAXIMUM NO. OF FITTINGS 9 ANSULAUTOMAN REGULATED RELEASE ASSEMBLY FIGURE 80 0110775 annul mimi sub no appli.pdf 7 1/10/2014 8:50:44AM - START OF LAST / BRANCH LINE START OF FIRST BRANCH LINE FIGURE 91 000754 1W NOZZLE SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-48 REV. 4 4-1-06 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements - 1.5 Gallon System DUCT, PLENUM, AND APPLIANCE PROTECTION This option allows for duct protection, plenum protection, appliance protection, or any combination. When usinga combination of plenum and duct protection only, only one duct nozzle, either a 1W, or a 2W, may be used. The previous Option 2 (using 2WH nozzle for plenum and duct protection) still can be utilized. For detailed design information, see previous version of this manual, Part No. 418087-06. Note: When using this option, all design parameters must be followed as listed in manual version -06. All distribution piping, supply and branch, must be 3/8 in. Schedule 46-black iron, chrome-plated, or stainless steel. Each 1.5 gallon tank allows a maximum of five flow numbers.* ,. The pipe length between the start of the first branch line and the start of the last branch line must not exceed 8 ft. (2.4 m). When the supply line is split, the combined length of both legs of the supply line (start of first branch line to start of last branch line) must not exceed 8 ft. (2.4 m). See Figure 91. The combined length of all branch lines must not exceed 22 ft. (6.7 m). See Figure 92. The requirements of the following table must not be exceeded: START OF LAST BRANCH LINE START OF FIRST BRANCH LINE SUPPLY LINE TEE TOTAL LENGTH MUST NOT EXCEED 8 Ft (2.4 m) (BRANCH LINES IN BOLD) COMBINED LENGTH MUST NOT EXCEED 22 Ft (6.7 m) FIGURE 92 omm Requirements Supply Duct Branch Line Plenum Branch Line Appliance Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 6 ft. 4 ft. loft. (12.2 m) (1.8 m) (1.2 m) (3m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 90° Elbow 9 4 . 4 6 Maximum Tees 1 1 2 3 Maximum Flow Numbers 5* 2 2 3 Exceptions: Six (6) flow numbers are allowed when a duct branch line is the last branch line on the piping network and no 1 nozzles are used to protect woks or griddles. Six (6)110w numbers are allowed when six (6)1N nozzles are used and none of the nozzles are used to protect woks and griddles. NOTE: Only live (5) flow numbers are allowed if a IN nozzle is used for wok or griddle protection. Six (6)110w numbers are allowed when only two (2) 3N nozzles are used. ansul mimi nub no appli.pdf 8 1/10/2014 8:51:26AM SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 4-1-06 REV. 6 SYSTEM DESIGN The ANSUL R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of toe R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. Both systems must actuate simultaneously. Each system must be designed and installed per its appropri- ate manual. Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub-sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. Duct Protection - Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (5-20 cm) into the center of the duct opening, discharging up. See Figure 1. 2-8 IN. (5-20 Cm) FIGURE 1 173 In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum; to a point just .beyond the damper assem- bly that will not interfere with the damper. Exceeding the maxi- mum of 8 in. (20 cm) in this way will not void the UL listing of the system. Previously listed 3 flow number and 5 flow number duct pro- tection detailed in earlier published manual, Part No. 418087- 06, can also still by utilized. DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER! 16 IN. (41 cm) DIAMETER One 1W nozzle (Part No. 419336) = one flow number 50 in. (127 cm) perimeter maximum 16 in. (41 cm) diameter maximum A 2WH nozzle (Part No. 78078) must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon sys- tem coverage (duct and plenum protection only). A 2WH nozzle is limited to a maximum of 75 in. (190 cm) perimeter or a maxi- mum diameter of 24 in. (61 cm) of coverage. The chart below shows the maximum protection available from each duct nozzle. I DUCT SIZES UP TO 100 IN. (254 cm) JWMETER/ 32 IN. (81.3 cm) DIAMETER I NOZZLE PLACEMENT REQUIREMENTS One 2Wzzle (Part No. 419337) = two flow numbers This section gives guidelines for nozzle type, positioning, and (-01 (254 cm) perimeter maximum quantity for duct, plenum, and individual appliance protection. This • 32 in. (81.3 cm) diameter maximum section must be completed before determining tank quantity and piping requirements. The R-102 system uses different duct nozzles depending on the/ 2W size of duct being protected. riptofl ozzle 1W Nozzle Part 3.0 Gallon 1.5 Gallon No. System System 419337 Maximum Maximum 100 in. (254 cm) 100 in. (254 cm) Perimeter Perimeter 419336 Maximum Maximum 50 in. (127 cm) 50 in. (127 cm) Perimeter Perimeter SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-12 REV.5 10-1-02 Multiple Nozzle Fryer Protection— Tilt Skillet/ Braising Pan Protection for tilt skillets or braising pans is to be based upon the coverage limitations provided for deep fat fryer protection. Refer to 'Section IV, DESIGN, starting on Page 4-10, for maximum fryer nozzle coverages and maximum fryer nozzle height limitations. Although the maximum 6 sq. ft. total surface cooking area require- ment applies to fryer protection, it does not apply to tilt skillets or braising pans. Each tilt skillet/braising pan protected module must not exceed the fryer limitations for "MAXIMUM SIZE MODULE OVERALL WITH DRIPBOARD" coverage per nozzle as described in Table on Page 4-11. Tilt skillets and braising pans generally utilize a hinged cover. Fryer protection nozzles are to be placed toward the front of the appli- ance to minimize the potential for the tilt skillet or braising pan 'cover to interfere with the nozzle discharge. See Figure 25. THE NOZZLE IS TO BE PLACED TOWARD THE FRONT OF THE APPLIANCE TO MINIMIZE THE POTENTIAL FOR THE SKILLET OR BRAISING PAN COVER TO INTERFERE WITH THE NOZZLE DISCHARGE. COVER MUST NOT INTERFERE WITH EDGE OF DISCHARGE PATTERN I FOR MINIMUM AND MAXIMUM NOZZLE HEIGHTS, REFER TO FRYER NOZZLE PARAMETERS FRYER NOZZLE USED FOR TILT SKILLET OR BRAISING PAN PROTECTION MUST BE POSITIONED NEAR THE FRONT EDGE OF THE PAN AND AIMED AT THE FRONT 10 BACK CENTERLINE OF THE PAN. THE DISCHARGE FROM THE NOZZLE(S) MUST COMPLETELY CLEAR THE PAN COVER WITH AN UNOBSTRUCTED VIEW TO THE BACK OF THE PAN. FIGURE 25 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-13 4-1-06 REV. 6 Range Protection 1-Flow Nozzle The A-i 02 system uses five different nozzles for the protection of ranges. Two of the design options require a one-flow nozzle and three of the design options require two-flow nozzles. NOTICE A 13 in. (33 cm) diameter wok pan is the largest wok size that can be protected on ranges. When protecting hot top ranges, the entire cooking surface must be protected. Range Protection (1-Flow Nozzle) Single and multiple burner ranges can be protected using a IN nozzle, Part No. 419335. The nozzle tip is stamped with IN, indi- cating that this is a one-flow nozzle and must be counted as one flow number. When using this nozzle for range. protection, the maximum length of the burner grates being protected with a single nozzle must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm) per nozzle. When protecting a range, the 1 nozzle must be located a maxi- mum of 10 in. (25.4 cm) from each burner grate centerline and must be aimed at the center of the cooking surface. See Figure 26. 40 IN. I (102 cm) T 30 IN. (76 cm) \ / 006539 10 IN. (25 cm) MAXIMUM 32 IN. NOZZLE '."I' (81 cm) ____________ MAXIMUM AIMING POINT 10 IN. / (25 cm) MAXIMUM 000540 FIGURE 26 When this type of hazard is equipped with a back shelf located above the range top, two protection options are available: One requires a 1 nozzle, Part No. 419333, and the other option requires a 260 nozzle, Part No. 419341. OptIon 1:1 F Nozzle: When using the 1 F nozzle for range protec- tion with or without back shelf, the maximum length of the burner grates being protected must not exceed 28 in. (71 cm) and the maximum area of the burner grates must not exceed 336 sq. in. (2168 sq. cm). See Figure 27 for nozzle location details. IF NOZZLE SHELF CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN. (28 cm) r20. AIM m) t 40 48 IN. POINT MINIMUM (102-122 cm) 14 IN. 12 IN IN.' MAXIMUM 5FRONTTOREA cU MAXIMUM CENTERLINE IF NOZZLE LOCATED-OVER FRONT EDGE OF BURNER GRATE AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONTTO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. FIGURE 27 000238 Option 2: 260 Nozzle: When using the 260 nozzle for range pro- tection with or without back shelf, the maximum length of burner grates being protected must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm). Nozzle must be located on the front edge of the burn- er grates and aimed at a point 10 in. (25 cm) from the back edge of the burner grates. Nozzle must be mount- ed 30 to 40 in. (76 to 102 cm) above the hazard sur- face. See Figure 28. 260 NOZZLE SHELF CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN. (28 cm) 30-40 IN. (76-102 cm) (25 cm) FROM BACK OF BURNER GRATES FIGURE 28 245 NOZZLE TIP LOCATION CENTER OF I COOKING SURFACE OR 113/8 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE (flfl'(ING 245 NOZZLE TIP LOCATION CENTER 0 COOKING SURFACE OR 113/8 IN. (29 cm) MAXIMUM FROM. CENTERLINE OF NOZ TO CENTER OF ANY 0. BURNER GRATE :ING P. FIGURE 30 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-14 REV.5 10-1-02 Range Protection 2-Flow Nozzle High Proximity Application (2-Flow Nozzle): 40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. This high proximity application uses the 245 nozzle, Part No. '41934O. The nozzle tip is stamped with 245 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 245 nozzle will protect a maximum cooking area of 672 sq. in. (4335 sq. cm) with a maximum longest dimension of 28 in. (71 cm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 29 and 30. 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE 50 IN. (127 cm) MAXIMUM HEIGHT OF 245 NOZZLE TIP 40 IN. (102 cm) MINIMUM HEIGHT OF 245 NOZZLE TIP 4 . FIGURE 29 NOTICE Four burner grates shown in Figure 30. For sin- gle or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (29 cm) maximum from nozzle centerline to center of any burner grate. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-15 10-1-02 REV.4 Range Protection 2-Flow Nozzle Medium Proximity Application (2-Flow Nozzle): 30 in. to 40 in. (76 cm to 102 cm) above the cooking surface. The medium proximity application uses the 260 nozzle, Part No. 419341. The nozzle tip is stamped with 260 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 260 nozzle will protect a cooking area of 768 sq. in. (4955 sq. cm) with a maximum dimension of 32 in. (81 cm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 31 and 32. 260 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE ri -, . I .401. (102 cm) MAXIMUM HEIGHT OF 260 NOZZLE TIP 1 30 IN. I MINIMUM HEIGHT OF 260 NOZZLE I TIP 0000 I (ING NO r.udRE 32 000760 NOTICE 0. Four burner grates shown in Figure 32. For sin- 0. or double burner grates, locate nozzle -at center of cooking surface. 260 NOZZLE TIP LOCATION CENTER OF COOKING SURFACE OR 10 IN. (25.4 Cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE 260 NOZZLE TIP LOCATION CENTE OF COOKING SURFACE OR 10 IN. (25.4 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE D. FIGURE 31 D. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-16 REV.6 4-1-06 Range Protection 2-Flow Nozzle Low Proximity Application Two (2-Flow Nozzles): 15 in. to 20 in. COOKING LONGITUDINAL (38 cm to 51 cm) above the cooking surface. ri__AREA CENTERLINE _________ The low proximity application requires two (2) 290 nozzles, Part No. 419342. The nozzle tip is stamped with 290 indicating this is a two flow noz- zle and must be counted as two flow numbers. - N19 Two (2) 290 nozzles will protect a cooking area of 1008 sq. in. I AR (6503 sq. cm) with a maximum dimension of 36 in. (91 cm). When using two of these nozzles for low proximity range protec- L.. 290 NOZZLE TIP tion, the nozzles must be positioned along the cooking surface _. L. ON perimeter to 1.5 in. (3.8 cm) inside the perimeter, and aimed at a LOCATN CENTER OF 450 angle along the longitudinal centerline of the range. See COOKING SURFACE ±2 IN. (5 Cm) Figures 33 and 34. 290 NOZZLE TIP LOCATION 0— 1.5 IN. (3.8 Cm) IN FROM EDGE 290 NOZZLE TIP OF COOKING SURFACE i \ [ LOCATION 0-1.5 IN. (0.- 3.8 cm) IN FROM EDGE OF J\5. COOKING 45 COOKING SURFACE t 000240 AREA T 15 IN. TO2OIN. 15 IN. TO2OIN. COOKING (381051 cm) I (381051 cm) AREA MAXIMUM MAXIMUM TUD2 I '1 __F 2900 00 00 0 1 zLE TIP N CENTER OF % I COOKING SURFACE ±2 IN. (5 cm) 290 NOZZLE TIP LOCATION FIGURE 33 0-1.5 IN. (3.8 cm) IN FROM EDGE 002278 OF COOKING SURFACE FIGURE 34 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-17 10-102 REV. 5 Griddle Protection 1-Flow Nozzle The R-102 system uses four different nozzles for the protection of griddles. One of the applications requires a 14low nozzle and i three of the applications require a 2-flow nozzle. NOZZLE LOCATION I I 0-2 IN. (0-5 cm) yr ~O2 High Proximity Application: 35 in.to 40 in. (89 to 102 cm) above I INSIDE PERIMETER _...I L._ OF COOKING SURFACE 'I (m) the cooking surface. I I ' I MAXIMUM I I HEIGHT This high proximity application uses the 1 nozzle, Part No. ii OF1N NOZZLE 419335. II I TIP The nozzle tip is stamped with 1 indicating this is a one-flow noz- I / I I / . I I I 35 IN. (89 cm) I MINIMUM I zie and must be counted as one flow number. I HEIGHT I One IN nozzle will protect a maximum cooking area of 1080 sq. EDGE II OF --*-I I COOKING II OF IN .1 I I NOZZLE TIP I I in. (6968 sq. cm) with the maximum longest side of 36 in. (91 cm). SURFACE I I I I When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to a maximum of 2 in. (5 cm) inside the perimeter, and aimed to the midpoint of the cooking surface. See Figure 35 and 36. NOTICE When using this type of griddle protection, only 5 flow numbers are allowed on a 1.5 gallon sys- tem and only ii flow numbers are allowed on a 3 gallon system. l / r . MIDPOINT OF COOKING SURFACE I I h IN NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN. (0-5cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. FIGURE 35 000241 FIGURE 36 m0243 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULCCEx747 Page 4-18 REV. 5 10-1-02 Griddle Protection 2-Flow Nozzle Option 1 - Nozzle Center Located High Proximity Application: 30 in. to 50 in. (76 cm to 127 cm) above the cooking surface. This high proximity application uses the 290 nozzle, Part No. 419342. The nozzle tip is stamped with 290 indicating this is a 24low noz- zle and must be counted as two flow numbers. One 290 nozzle will protect a maximum cooking area of 720 sq. in. (9290 sq. cm) with a maximum dimension of 30 in. (76 cm). When using this nozzle for high proximity applications, the nozzle must be positioned within 1 in. (2.5 cm) of the center of the cook- ing surface and pointed vertically down. See Figure 38 and 37. CENTER LINE OF GRIDDLE SURFACE * 1 IN. (2 cm) IN ANY DIRECTION I I 50 IN. I (127 cm) MAXIMUM A. I HEIGHT I 0F290 NOZZLE TIP I 301N. I I (76cm) MINIMUM HEIGHT OF 290 NOZZLE TIP FIGURE 37 000244 COOKING NOZZLE AREA NOZZLE 1 IN. (2 cm) LOCATION I . -.-i i..- MAXIMUM COOKING AREA 1 IN. (2 cm) MAXIMUM CENTER OF GRIDDLE SURFACE OR A MAXIMUM DIMENSION OF 20.6 IN. (52 cm) FROM NOZZLE CENTERLINE TO FURTHEST CORNER OF GRIDDLE FIGURE 38 000773 SECTION IV - SYSTEM DESIGN ULEX. 3470 ULC CEx747 Page 4-19 10-1-02 REV.3 2-Flow Griddle Protection (Continued) Option 2— Nozzle Perimeter Located High Proximity Application: 30 in. to 50 in. (76 cm to 127 cm) above the cooking surface. This high proximity application uses the 260 nozzle, Part No. 419341. The nozzle' tip is stamped with 260 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 260 nozzle will protect a maximum cooking area of 1440 sq. in. (9290 sq. cm) with a maximum dimension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to 2 Jn. (5.1 cm) inside perimeter, and aimed at the center of the cooking surface. See Figure 39 and 40. NOZZLE LOCATION t II 0-21N.(0-5cm) I INSIDE PERIMETER _4I 14.— OF COOKING SURFACE 50 IN. - (127 cm) I MAXIMUM HEIGHT OF 260 /x NOZZLE TIP I cm)l M I I I/ EDGE I I OF 0i I' COOKING I SURFAC?J... LHEIGHT E TIP I 1 000243 0 . FIGURE 39 000243 -1 - COOKING AREA r r MIDPOINT OF COOKING SURFACE COOKING p I AREA AIM POINT LU 260 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN. (0—i cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. FIGURE 40 000241 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-20 REV. 4 10-1-02 2-Flow Griddle Protection (Continued) Option 2— Nozzle Perimeter Located (Continued) Medium Proximity Application: .20 in. to 30 in. (51 cm to 76 cm) above the cooking surface. The medium proximity application uses the 290 nozzle, Part No. 419342. The nozzle tip is stamped with 290 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 290 nozzle will protect a maximum cooking area of 1440 sq. in. (9290 sq. cm) with a maximum dimension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the perimeter to 2 in. (5.1 cm) inside perimeter, and aimed at the center of the cooking surface. See Figure 41 and 42. COOKING AREA CENTER OF COOKING SURFACE I lWCOOKING IjIT f AREA AIM POINT 290 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN. (0— 5 cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT CENTER OF COOKING SURFACE. FIGURE 41 O24I I NOZZLE LOCATION . f I 0 — 2 IN. (0 — 5 cm) . I INSIDE PERIMETER 30 IN. -, OF COOKING SURFACE I I (76 cm) I MAXIMUM I /) HEIGHT II 0F290 I I II NOZZLE TIP I / I 20 IN. (51 cm) I MINIMUM I II / Il HEIGHT I II . / 0F290 I I NOZZLE TIP I EDGE OF COOKING SURFACE p. FIGURE 42 243 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-21 10-1-02 REV.3 2-Flow Griddle Protection (Continued) Option 2— Nozzle Perimeter Located (Continued) Low Proximity Application: 10 in. to 20 in. (25 cm to 51 cm) above the cooking surface. The low proximity application uses the 2120 nozzle, Part No. 419343. The nozzle tip is stamped with 2120 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 2120 nozzle will protect a maximum cooking area of 1440 sq. in.. (9290 sq. cm) with a maximum dimension of 48 in. (122 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the perimeter to 2 in. (5.1 cm) inside perime- ter, and aimed at the center of the cooking surface. See Figure 43 -and 44. I NOZZLE LOCATION P I I 0-2 IN. (0-5cm) . t I INSIDE PERIMETER 20 IN. L_ OF COOKING SURFACE (51 cm) MAXIMUM HEIGHT I I 0F2120 II ./7 I I II NOZZLE TIP 10 IN. (25cm) I MINIMUM I HEIGHT I II 0F2120 I II NOZZLE TIP 000243 EDGE OF COOKING SURFACE FIGURE 43 000243 COOKING AREA CENTER OF 1 COOKING SURFACE COOKING I I I I AREA AIM POINT 2120 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN. (0_5 Cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT CENTER OF COOKING SURFACE FIGURE 44 24I 12 IN. (30.5 cm) MINIMUM MAXIMUM INTERNAL BROILER SIZE 32 X 34 IN. (81 x86CM) FIGURE 45 MAXIMUM It BROILER SL (109 X 79 cn 46 000247 TOP VIEW SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-22 REV. 4 4-1-06 Chain Broiler Protection The R-102 system uses two iN Nozzles (Part No. 419335) for chain broiler protection. The nozzle tip is stamped iN, indicating that this is a one-flow nozzle and must be counted as one flow number (total of two flow numbers for each chain broiler being pro- tected). Two iN nozzles are always needed for chain broiler protection when the hazard area to be protected does not meet the "Overhead Broiler Protection" requirements. The maximum inter- nal size of the broiler is 43 x 31 in. (109 cm x 79 cm). The nozzles must be positioned at each end of the enclosed cooking chamber 1 to 3 in. (2.5 to 7.5 cm) above the surface of the chain and a max- imum distance of 4 in. (10 cm) away from the broiler opening. The nozzles may be mounted at either corner as long as they are at opposite ends of the chain broiler and positioned to discharge diagonally across the top of the chain. See Figures 45 and 46. Overhead Chain Broiler Protection The R-102 system uses two 1W Nozzles (Part No. 419336) for overhead chain broiler protection. The nozzle tip is stamped with 1W, indicating that this is a one-flow nozzle and must be counted as one flow number. Overhead protection is only available for chain broilers with exhaust opening dimensions that are not less than 60% of the internal broiler length and not less than 60% of the internal broiler width, to a minimum size of 12 in. x 12 in. (30.5 x 30.5 cm). Internal broiler size can not be larger than 32 in. x 34 in. (81 x 86 cm). When overhead protection is used, the nozzles must be centered above the exhaust opening within 4 to 8 in. (10 to 20 cm) of each other and they must be located 10 to 26 in. (25 to 66 cm) above the top of the broiler surface. See Figure 47. 245 FIGURE 47 000248 The nozzles may vary in position as long as they are evenly spaced from the exhaust center and are always 1800 opposite of each other. If the opening is not square, the nozzles must be posi- tioned along the centerline, parallel to the longest side of the open- ing. See Figure 48. TOP VIEW FIGURE 48 000249 Note: The GB Metal Blow-off Gap must be used when using chain broiler protection. VERTICAL EDGE OF BROILER OPENING AIM AT CENTER OF BROILER OPENING IN NOZZLE (RART 140.419335) 121N r NOZZLE I mi CATION ZONE 130 crn)6 IN. (15 cm) BIN! i's CM) I AT ur BROILER OPENING I 0] SECTION IV - SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-23 7-1-09 REV.8 Overhead Chain Broiler Protection (Continued) Example No. 1 - Internal broiler size is 24 in. long x 20 in. (61 x 51 cm), with an opening of 16 in. x 1 (40.6 x 40.6 cm). To determine minimum opening size, multiply the internal length and the internal width by 0.6: Length of opening -24 in. x 0.6 = 14.4 in. (61 cm 0.6 = 36.6 cm) Width of opening -20 In. x 0.6 = 12.0 in. (51 cm x 0.6 = 30.5 cm) The minimum allowable opening for overhead protec- tion would be 14.4 in. x 12.0 in. (36.6 x 30.5 cm). This example would be acceptable for overhead pro- tection. Salamander Broiler Protection The R-102 system uses three different nozzle locations for sala- mander broiler protection. All of the design options require a one- flow nozzle. Salamander Broiler Protection - 1 (1-Flow) Nozzle Overhead A salamander broiler with a maximum hazard area (internal broil- er chamber) of 16 in. (41 cm) deep x 29 in. (74 cm) wide can be protected using a IN nozzle, Part No. 419335. The nozzle tip is stamped with IN, indicating that this is a one-flow nozzle. The single IN nozzle must be located directly in line with either vertical edge of the broiler opening, 6 in. (15 cm) to 12 in. (30 cm) In front of the broiler, and 0 in. to 12 in. (30 cm) above the top of the broiler. The nozzle must be aimed at the center of the broiler 'opening. See Figure 57a. Salamander Broiler Protection -1 F(1-Flow) Nozzle or chamB 15 In. (39i) deep x 31 in cm) Wide can be protected using a 1 F nozzle, Part No. 419333. The nozzle tip is stamped with IF, indicating that this is a one-flow, nozzle. The single IF nozzle must be located directly in line with the cen- ter of the broiler opening, 8 in. (20 cm) to 12 in. (30 cm) in front of the broiler and 12 in. (30 cm) to 18 in. (46 cm) above the top of the broiler. The nozzle must be aimed at the center of the top broiler opening when the grate Is located In the middle position. The noz- zle must be orientated so the nozzle tip flats are parallel with the grate left to right centerline. See Figure 57b. NOZZLE IF NOZZLE GIN. LOCATION ZONE (PART NO. (15 Cm) 419333) j (20 CM) - 4IN \\ '121N. (10cm)' 1(30cm) AIM AT CENTER OF THE AIM AT CENTER OF THE lop 'TOP BROILER OPENING BROILER OPENING WHEN THE WHEN THE GRAVE IS GRATE IS LOCATED IN THE LOCATED IN THE MIDDLE POSITIONAIM AT CENTER MIDDLE POSITION OF BROILER OPENING FIGURE 57b amm Salamander Broiler Protection = IN (1-Flow) Nozzle Local A salamander broiler with a maximum hazard area (internal broil- er chamber) of 15 in. (38 cm) deep x 31 in. (79 cm) wide can be protected using a IN nozzle, Part No. 419335. The nozzle tip Is stamped with 1 N, indicating that this Is a one-flow nozzle. The single IN nozzle must be located above the grate on either vertical edge of the broiler opening. The nozzle must be aimed at the center of the grates. See Figure 57c. I AT CENTER OF ORATES FIGURE 57c ME Example No. 2- Internal broiler size is 30 in. long x 24 In. wide (76 x 61 cm) with an opening of 22 in. x 12 in. (56 x 30 cm). To determine minimum opening size, multiply internal length and internal width by 0.6: Length of opening -30 in. x 0.6 = 16.0 in. (76 cm x 0.6 = 45.7 cm) Width of opening -24 in. x 0.6 = 14.4 in. (61 cm x 0.6 = 36.6 cm) Minimum allowable opening for overhead protection would be 18 in. x 14.4 in. (45.7 x 36.6 cm). Because this broiler has an opening of 22 in. x 12 in., VV the 12 in. width is below the minimum allowable cal- culated dimension of 14.4 in. (36.6 cm) and therefore would not be acceptable for overhead protection. FIGURE 578 amm ANSUL 2009 Unlocked-ansul r102 2009 manuaLpdf 52 NIP V1512014 10:44:03 AM VERTICAL EDGE OF BROILER OPENING SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-23 4-1-06 REV. 7 Overhead Chain Broiler Protection (Continued) Example No. 1 - Internal broiler size is 24 in. long x 20 in. wide (61 x 51 cm), with an opening of 16 in. x 16 in. (40.6 x 40.6 cm). To determine minimum opening size, multiply the internal length and the internal width by 0.6: Length of opening -24 in. x 0.6 = 14.4 in. (61 cm x 0.6 = 36.6 cm) Width of opening -20 in. x 0.6 = 12.0 in. (51 cm x 0.6 = 30.5 cm) The minimum allowable opening for overhead protec- tion would be 14.4 in. x 12.0 in. (36.6 x 30.5 cm). This example would be acceptable for overhead pro- tection. Example No. 2 - Internal broiler size is 30 in. long x 24 in. wide (76 x 61 cm) with an opening of 22 in. x 12 in. (56 x 30 cm). To determine minimum opening size, multiply internal length and internal width by 0.6: Length of opening -30 in. x 0.6 = 18.0 in. (76 cm x 0.6 = 45.7 cm) Width of opening - 24 in. x 0.6 = 14.4 in. (61 cm x 0.6 = 36.6 cm) Minimum allowable opening for overhead protection would be 18 in. x 14.4 in. (45.7 x 36.6 cm). Because this broiler has an opening of 22 in. x 12 in., the 12 in. width is below the minimum allowable cal- culated dimension of 14.4 in. (36.6 cm) and therefore would not be acceptable for overhead protection. Upright/Salamander Broiler Protection The R-102 Restaurant Fire Suppression System uses one 1N Nozzle, Part No. 419335, for upright/salamander broiler protection. The nozzle tip is stamped with 1 N, indicating that this is a one-flow nozzle. One 1 N nozzle will protect a maximum hazard area (internal broil- er chamber) of 16 in. (41 cm) deep x 29 in. (74 cm) wide. The single 1 N nozzle must be located directly in line with either vertical edge of the broiler opening, 6 in. (15 cm) to 12 in. (30 cm) in front of the broiler, and 0 in. to 12 in. (30 cm) above the top of the broiler. The nozzle must be aimed at the center of the broiler opening. See Figure 49. Upright/Salamander Broiler Protection The A-i 02 system uses two 1/2N Nozzles (Part No. 419334) for all upright/salamander broiler protection. The nozzle tip is stamped 1/2N, indicating that this is a half-flow nozzle. A pair of these noz- zles will equal one flow number. Two 1/2N nozzles will protect a maximum hazard area (internal broiler chamber) of 30 in. x 32.5 in. (76 cm x 82.5 cm). These noz- zles must always be used in pairs on an upright/salamander broil- er. One nozzle must be positioned above the grate and pointed at the back opposite corner of the broiler chamber. The second noz- zle must be pointed down into the center of the drip pan through the open slot. See Figure 50. Note: If metal blow-off caps are required for upright broiler or sala- mander broiler protection, use (2) two IN nozzles, Part No. 419335, instead of 1/2N nozzles. SALAMANDER BROILER 0001 UPRIGHT BROILER BROILER CHAMBER AIM AT CENTER OF BROILER OPENING iN NOZZLE (PART NO. 419335) NOZZLE - LOCATION ZONE 12 IN. (30 cm) 6 IN. (15 cm) t 3 (15 cm) - -------- I AT CENTER OF BROILER OPENING FIGURE 49 007128 FRONT VIEW SIDE VIEW FIGURE 50 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-24 REV. 6 4-1-06 Gas-Radiant/Electric Char-Broiler Protection The R-1 02 system uses the 1 N nozzle, (Part No. 419335) for gas- radiant/electric char-broiler protection. The nozzle tip on the 1 nozzle is stamped with a iN, indicating that this is a one-flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip must be located 15 to 40 in. (38 to 102 cm) above the hazard surface. When using this nozzle for gas-radiant/electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 51. t 40 IN. .% 4& (102 cm) MAXIMUM , , 15 I438 cm) I MINIMUM I _i I 000257 FIGURE 51 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 425 10-1-02 REV.6 Lava Rock (Ceramic) Char-Broiler Protection The R-102 system uses the iN Nozzle (Part No. 419335) for all lava rock char-broiler protection. The nozzle tip is stamped with 1 N, indicating that this is a one-flow nozzle and must be counted as one flow number. One 1 N nozzle will protect a hazard which has a maximum length of 24 in. (61 cm) and a total cooking area which does not exceed 312 Sq. in. (2013 sq. cm). The nozzle tip must be located 18 to 35 in. (46 to 89 cm) above the hazard surface. When using this nozzle for lava rock (ceramic) char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and angled to the center. See Figure 52. COOKING AREA COOKING All AREA - I - I I T I I I t . / ( 35 IN. (89 I i MAXIMUM I S' /j 1BIN. I / I (46cm) I MINIMUM I Natural Charcoal Broiler Protection The R-102 system uses the 1 Nozzle (Part No. 419335) for all natural charcoal broiler protection. The nozzle tip is stamped with 1 N indicating that this is a one-flow nozzle and must be counted as one flow number. One 1 nozzle will protect a hazard area which has a maximum length of 24 in. (61 cm) and a total cooking area which does not exceed 288 sq. in. (1858 sq. cm). The nozzle tip must be located 18 to 40 in. (46 to 102 cm) above the hazard surface. When using this nozzle for natural charcoal broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the max- imum cooking area and aimed at the center of the cooking surface. See Figure 53. .The coverage of such appliances only applies when the depth of the charcoal does not exceed 4 in. (10 cm). COOKING - COOKING AREA AREA ./2 (102cm) 40 IN. \ / I MAXIMUM I I 4 IN. (10 cm) \ /,-i- I 181N. / / I (46 c' I MAXIMUM DEPTH MINIMUM FIGURE 52 - FIGURE 53 SECTION IV - SYSTEM-DESIGN UL EX. 3470 ULC CEx747 Page 4-26 REV. 5 10-1-02 Alternate Ceramic/Natural Charcoal Char-broiler Protection The R-102 system may also use the 3N nozzle (Part No. 419338) for all ceramic (lava rock) and natural charcoal char-broiler protec- tion. The nozzle tip is stamped with 3N, indicating that this is a three-flow nozzle and must be counted as three flow numbers. One 3N nozzle will protect a hazard which has a maximum length of 30 in. (76 cm) and.a total cooking area which does not exceed 720 sq. in. (4645 sq. cm). The nozzle tip must be located 14 to 40 in. (36 to 102 cm) above the hazard surface. The nozzle must be positioned anywhere along or within the perimeter of the max- imum cooking area and angled to the center. See Figure 54. For natural charcoal char-boiler protection, this coverage only applies when the depth of the charcoal does not exceed 4 in. (10 cm). COOKING -4'-_... COOKING AREA AREA I.-... 1i II I I Wood Fueled Char-Broiler Protection The R-102 system uses the 3N Nozzle (Part No. 419338) for mesquite char-broiler protection. The nozzle tip is stamped with 3N indicating that this is a three-flow nozzle and must be counted as three flow numbers. One 3N nozzle will protect a hazard which has a maximum length of 30 in. (76 cm) and a total cooking area which does not exceed 720 sq. in. (4645 sq. cm). The nozzle tip must be located 14 to 40 in. (36 to 102 cm) above the hazard surface. The nozzle must be positioned anywhere along or within the perimeter of the max- imum cooking area and aimed at the center of the cooking surface. See Figure 55. Mesquite logs and pieces, no larger than 4 in. (10 cm) in diameter, may be protected with a maximum allowable wood depth of 6 in. (15 cm). COOKING - COOKING AREA AREA AREA I I I I Jr + I / (102cm) 401N. / I 40 IN. / ( MAXIMUM (102 cm) \ / MAXIMUM 41N.(lOcm\\/h •\ 4/h. 14 IN. MAXIMUM \ / l IN \36 cm) 6 IN. (l5cm) DEPTH MINIMUM MAXIMUM (36 cm) N DEPTH UM MINIM I FIGURE 54 FIGURE 55 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-26 REV. 5 10-1-02 Alternate Ceramic/Natural Charcoal Char-broiler Protection The R-102 system may also use the 3N nozzle (Part No. 419338) for all ceramic (lava rock) and natural charcoal char-broiler protec- tion. The nozzle tip is stamped with 3N, indicating that this is a three-flow nozzle and must be counted as three flow numbers. One 3N nozzle will protect a hazard which has a maximum length of 30 in. (76 cm) and a total cooking area which does not exceed 720 sq. in. (4645 sq. cm). The nozzle tip must be located 14 to 40 in. (36 to 102 cm) above the hazard surface. The nozzle must be positioned anywhere along or within the perimeter of the max- imum cooking area and angled to the center. See Figure 54. For natural charcoal char-boiler protection, this coverage only applies when the depth of the charcoal does not exceed 4 in. (10 cm). COOKING AREA COOKING AREA _ -N- — I I II . . Wood Fueled Char-Broiler Protection The 8-102 system uses the 3N Nozzle (Part No. 419338) for mesquite char-broiler protection. The nozzle tip is stamped with 3N indicating that this is a three-flow nozzle and must be counted as three flow numbers. One 3N nozzle will protect a hazard which has a maximum length of 30 in. (76 cm) and a total cooking area which does not exceed 720 sq. in. (4645 sq. cm). The nozzle tip must be located 14 to 40 in. (36 to 102 cm) above the hazard surface. The nozzle must be positioned anywhere along or within the perimeter of the max- imum cooking area and aimed at the center of the cooking surface. See Figure 55. Mesquite logs and pieces, no larger than 4 in. (10 cm) in diameter, may be protected with a maximum allowable wood depth of 6 in. (15 cm). COOKING AREA ..-k..COOKING AREA I I \ / (102 cm) 4OIN. I / 401 I (10. n) MAXIMUM I MAXIMUM \I 4 IN. (10 CM) \ /14 MAXIMUM / (36 c) 6 IN. (15 cm) \ / 14 IN. (36 cm) N. DEPTH MINIMUM 1 DEPTH I MINIMUM MAXIMUM I _____________00WM - flhI FIGURE 54 FIGURE 55 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-28 REV. 5 4-1-06 Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. Minimum Hazard Maximum Hazard Dimensions Nozzle Quantity Duct or Transition Length - Unlimited 1 (Single Nozzle) Perimeter —50 in. (127 cm) Diameter - 16 in. (40.6 dm) Duct or Transition Length - Unlimited 1 (Single Nozzle) Perimeter - 100 in. (254 cm) Diameter —31 7/8 in. (81 cm) Duct or Transition Length - Unlimited 2 (Dual Nozzle) Perimeter - 150 in. (381 cm) Diameter —48 in. (122 cm) Electrostatic Precipitator Individual Cell 1 (At Base of Duct) Plenum Length - lOft. (3.1 m) 1 (Horizontal Protection) ' Plenum Length —6 ft. (1.8 m) 1 (Horizontal Protection) Width —4 ft. (1.2 m) 1 Plenum Length —4 ft. (1.2 m) 1 (Vertical Protection) Width —4 ft. (1.2 m) Fryer (Split or Maximum Size Non-Split Vat) (without drip board) 14 in. (36 cm) x 15 in. (38 cm) 1 Low Proximity Fryer (Split or Maximum Size Non-Split Vat) (without drip board) 14 1/2 in. (37 cm) x 14 in. 36cm) 1 Medium Proximity Fryer (Split or Maximum Size Non-Split Vat) (without drip board) 15 in. (38 cm) x 14 in. (36 cm) High Proximity 1 Medium Proximity 1 Fryer (Non-Split Vat Only) Maximum Size (without drip board) 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 Low Proximity 1 Maximum Size (without drip board) 18 in. (45.7 cm) x 18 in. (45.7 cm) High Proximity 1 For multiple nozzle protection of single fryers, see detailed Information on Pages 4-12 through 4-14. Nozzle Tip Nozzle Nozzle Heights Part No. Stamping - Flow No. - 430912 1W - 419337 2W - 419337 2W - 419334 1/2N - 419335 1 - 430192 1W - 419336 1W - 419336 1W 13—l6in. 419342 290 (33 —41 cm) 16-27in. 419342 290 (41 —69 cm) 27-47 in. 419339 230 20-27 in. 419340 245 21 —34 in. 419338 3N 13-16 in. 419342 290 25-35 in. 419338 3N (64-89 cm) SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-29 4-1-06 REV. 5 Nozzle Application Chart (Continued) Minimum Nozzle lip Hazard Maximum Hazard Dimensions Nozzle Quantity Nozzle Heights Nozzle Part No. Stamping - Flow No. Fryer (Non-Split Maximum Size Vat Only)* (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in. (38 cm x 36 cm)) High Proximity 1 27-47 in. 419339 230 Medium Proximity 1 20-27 in. 419340 245 Maximum Size (with drip board) 25 3/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 21 —34 in. 419338 3N Low Proximity 1 13-16 in. 419342 290 Maximum Size (with drip board) 18 in. (45.7 cm) x27 3/4 in. (70.5 cm) High Proximity 1 25-35 in. 419338 3N (64-89 cm) 'Fryer (Split or Maximum Size Non-Split Vat) (with drip board) 14 in. (36 cm) x 21 in. (53 cm) 1 13— 16 in. 419342 290 Low Proximity (33-41 cm) Fryer (Split or Maximum Size Non-Split Vat) (with drip board) 141/2 in. (37 cm) x 261/2 in. (67 cm) 1 16-27 in. 419342 290 Medium Proximity (41 —69 cm) Range Longest Side 1 30-40 in. 419335 1 32 in. (81 cm) (76-102 cm) Area - 384 sq. in. (2477 sq. cm) Longest Side 40-48 in. 419333 1 F 28 in. (71 cm) (102— 122 cm) Area —336 sq. in. (With Backshelt) (2168 sq. cm) Longest Side (High Proximity) 1 40-50 in. 419340 245 28 in: (71 cm) (102— 127 cm) Area - 672 sq. in. (4335 sq. cm) Longest Side (Medium Proximity) 1 30-40 in. 419341 260 32 in. (81 cm) (76— 102 cm) Area-768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 15-20 in. 419342 290 36 in. (91 cm) (38 —51 cm) Area —loO8 sq. in. (6503 sq. cm) - For multiple nozzle protection 01 single fryers, see detailed information on Pages 4-7 through 4-11. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-31 3-1-04 REV. 6 Nozzle Application Chart (Continued) Minimum Nozzle Tip Hazard Maximum Hazard Dimensions Nozzle Quantity Nozzle Heights Nozzle Part No. Stamping - Flow No. .. Wood Fueled Char-Broiler Longest Side —30 in. (76 cm) 1 14-40 in. 419338 3N Area - 720 sq. in. (36 - 102 cm) (4645 sq. cm) Upright Broiler Length —32.5 in. (82.5 cm) 2 - 419334 1/2N Width —30 in. (76 cm) Salamander Length —32.5 in. (82.5 cm) 2 - 419334 1/2N Broiler Width —30 in. (76 cm) Wok 14 in. —30 in. (36-76 cm) 1 35-45 in. 419341 260 Diameter (89.— 114 cm) 3.75 —8.0 in. (9.5 —20 cm) Deep 11 in. —24 in. (28-61 cm) 30-40 in. 419335/417332 1 N/l NSS Diameter (76 - 102 cm) 3.0— 6.0 in. (8— 15.2 cm) Deep 10 FT. (3.1 m) MAXIMUM SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-5 4-1-06 REV. 4 Plenum Protection The A-i 02 system uses the 1W Nozzle (Part No.. 419336) or the 1 N Nozzle (Part No. 419335) for plenum protection. The 1W noz- zle tip is stamped with 1W and the 1 nozzle tip is stamped with 1 N, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. VERTICAL PROTECTION - GENERAL One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more than-2 ft. (.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum of 4 ft. (1.2 m) apart down the entire length of the plenum. The plenum width must s. not exceed 4 ft. (1.2 m). (The 1W nozzle can be used on single or V-bank filter arrangements.) See Figure 6. FILiUFft b Om'97 . When protecting plenums with the 1W nozzle, two options of cov- erage are available: Option 1: The 1W nozzle must be on the center line of the single or "V" bank filter and positioned within 1-20 in. (2.5-51 cm) above the top edge of the filter. See Figure 7. 20 IN. (51 cm) MAXIMUM Option 2: The 1W nozzle must be placed perpendicular, 8-12 in. (20-30 cm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (5 cm) from the perpendicular center line of the filter. See Figure 8. CM) (20 Cm) IUM NOZZLE TIP MUST BE THIS AREA FIGURE 8 comm HORIZONTAL PROTECTION - OPTION 1 1 NOZZLE - PART NO. 419335— SINGLE BANK PROTECTION One 1 N nozzle will protect 10 linear feet (3.1 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the hood to the tip of the L nozzle. See Figure 9. 1 IN. (2.5 Cm) MINIMUM 20 IN. (51 cm) MAXIMUM 1 IN. (2.5 Cm) MINIMUM FIGURE 7 000199 2 FIGURE 11 FIGURE 12 OG FIGURE 13 000207 FIGURE 14 000 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-6 REV.5 4-1-06 Plenum Protection (Continued) HORIZONTAL PROTECTION - OPTION 2 1W NOZZLE - PART NO. 419336— "V" BANK PROTECTION One 1W nozzle will protect 6 linear feet (1.8 m) of "V" bank plenum. The nozzle must be mounted horizontally, positioned 1/3 the filter height down from the top of the filter. Nozzles can be located at 6 ft. (1.8 m) spacings on longer plenums. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the hood to the tip of the nozzle. See Figure 10. 1W NOZZLE FIGURE 10 000524 1 N NOZZLE - PART NO. 419335— "V" BANK PROTECTION Two IN nozzles will protect 10 linear feet (3.1 m) by 4 ft. (1.2 rn) wide of "V" bank plenum. The nozzles must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the hood to the tip of the nozzle. See Figure 11. For a plenum, either single or "V" bank, with a linear extension longer than lo feet (3.1 m), each bank may be protected using one 1 nozzle every 10 ft. (3.1 m) or less depending on the overall length of the plenum. See Figure 12. The nozzles may point in the opposite directions as long as the entire plenum area is protected, and the 10 ft. (3.1 m) limitation is not exceeded. See Figure 13. The nozzle positioning shown in Figure 14 is not an acceptable method of protection because the plenum area directly under the tee is not within the discharge pattern of either nozzle. 10 Fr. (3.1 m) MAXIMUM tOFT. (3.1 m) MAXIMUM 10 Ft (3.1 m) MAXIMUM FT.(9.1 m) FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD SPLIT VAT NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 16 )F FRYER - SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-8 REV.6 4-1-06 Fryer - Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection Max. Size Max. Size Overall Type of Nozzle Height Frypot Only With Dripboard Nozzle Above Top of Fryer Full or Split Vat Full or Split Vat 230 27 in. to 47 in. l4 in. xl5in. l4 in. x2lin. (69cmtoll9cm) (36cmx38cm) (36cmx53cm) Full or Split Vat Full or Split Vat 245 20 in. to 27 in. 14 in. x 15 in. 14 in. x 21 (51 cm to 69 cm) (36cmx38cm) (36cmx53cm) Full or Split Vat Full or Split Vat 290 13 in. to 16 in. 14 in. x 15 in. 14 in. x 21 in. (33 cm to 41 cm) (36 cm x 38 cm) (36 cm x 53 cm) Full or Split Vat Full or Split Vat 290 16 in. to 27 in. 141/2 in. xl4in. 14 1/2 in. x 26 1/2 in. (41 cmt069cm) i.(37cmx38cm) (37cmx67cm) Nozzle Location See Figure 15 and 16 See Figure 15 and 16 See Figure 17 See Figure 17 :] I I I. I I I III I I I i I I I 1 I TOP OFFRYER I FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 15 002200 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-9 4-1-06 REV. 8 Fryer - Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location 19.5 in. x 19 in. 19.5 in. x 253/8 in. 290 13 in. to 16 in. See Figure 17 (50 cm x 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in. x 19 in. 19.5 in. x 25 3/8 in. 3N See Figure See Figure 18 (50 cm x 48 cm) (50 cm x 65 cm) 18 18 in. x18in. l8 in. x273/4in. 3N 25 in. t035in. See Figure 19 (46 cm x 46 cm) (46 cm x 70.5 cm) (64 cm to 89 cm) FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA ± 3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND * 1 IN. (2.5 cm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND AIMED AT THE MIDPOINT OF THE COOKING AREA. FIGURE 17 34 IN. (86 Cm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA lin.(53cm) I MINIMUM I VERTICAL NOZZLE HEIGHT FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 18 m2287 TOP OF FRYER RIGHT-TO-LEFT CENTERLINE FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 19