Loading...
HomeMy WebLinkAbout2036 CORTE DEL NOGAL; ; AS100139; Permit5/9/24, 9:03 AM AS100139 Permit Data City of Carlsbad Sprinkler Permit 2036 CORTE DEL Job Address: NOGAL Permit Type: SPRINK Parcel No: 2130612900 Lot #: 0 Permit No: AS100139 Status: ISSUED Applied 11/3/2010 Approved: 11/3/2010 Reference No.: Issued: 11/3/2010 PC #: Inspector: Project Title: CRW T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: AZTEC FIRE & SAFETY 8107 COMMERCIAL ST LA MESA, CA Owner: RU INVESTMENTS L L C C/O MICHAEL BELLO 2350 SE BRISTOL ST NEWPORT BEACH CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank Ill Vertical Sidewall Conventional Bulletin 014 Rev. D Model Fl FR Series Quick Response Standard Spray Horizontal Sidewall Recessed Pendent/F1/F2 Upright Pendent CD C CD 0 CD < Le ReIiabk Model Fl FR 56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR 56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR 56 Concealed Sprinkler Types Standard Pendent Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Product Description Reliable Models F1FR, Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- dard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1FR Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprin- klers. This quick response enables the Model F1FR Series sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Recessed Horizontal Sidewall Application Quick response sprinklers are used in fixed fire protèc- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflec- tor style and sprinkler type are in accordance with the lat- est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. v r ). :.• Recessed Pendent/FP The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K Factor Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US Metric Upright j Pendent Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position ½' (15mm) ½" NPT(RY2) 5.6 1 80 2.25" (57mm) 1 1, 2. 3. 4 RA142501 RA 1414 (X2) Conventional-Install in Upright or Pendent Position 15mm) ½" NPT(RY2) 5.6 1 80 1 57mm 1 3.4 RA1475 ' cULus listed corrosion resistant (Polyester coated) sprinkler. (21 Polyester coated FM approved sprinkler. t.4 Upright Pendent Conventional Model Fl FR 56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) ½" NPT(R½) 5.6 80 2.25" (57mm) RA1414 Refer to escutcheon data table for approvals and dimensions. 1• I Model F1FR 56/F1 or F2 2 5/8 014 (66.7mm) —. HOLE IN CEILING 2 5/I6 DL4 (58.7mm) - CUP IX ;12 REDUCER I I \ I / CEILING FACE OF F,mNG To FAC E OF CEILING IMENSION 0) ADJUSTMENT 011r,"2 (I) REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Model F1FR 56/FP 2. Vertical Sidewall Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US I I Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) 1/2" (15mm) ½" NPT(R1/2) 5.6 8.0 2.25" (57mm) 1:2.3.4 RA1485 15mm ½" NPT(R1/2) 5.6 8.0 2.25" (57mm) 4() "ILPC Approval is for pendent position only. Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Sprinkler _________________ Height and Type of Approval Nominal Orifice Thread Size Identification US I Metric Light Hazard Ordinary O I Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1435 FACE OF FITTING - To FACE OF CEILING DIMENSION I 1/4" MIN. [31.8mm) I -2 1/4" HOLE DL4. 4" 6" CEILING TO [57.2mm] [3 2mm] [101.6mm-152.4mm] 1" X 1/2" REDUCER DEFLECTOR - 1 15116" D14 (49.2m 27/32" DIA. [72.2mm) I W771 lt,~N~Y TURN COLLAR TIGHT AGAINST SPRINKLER WRENCH BOSS, o,JFGoJ ADJUSTMENT (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Horizontal Sidewall 3. Model Fl FR Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover /2' (15mm) 5.6 80 112" NPT F1FR 1350F/570C 1350F/570C 100°F/38°C Orange 12 2 RA1414 1/2" (15mm) 5.6 80 ½' NPT I F1FR I 155°F/68°C 1350F/57CC 1000F/38CC I Red 1 1. 2, 411 RA1414 5.6 80 112" NPT F1FR 1750F/790C 1650F/740C 100°F/38°C Yellow 1.2 RA1414 5.6 80 ½' NPT F1FR 200°F/930C 1 1650F/740C 100°F/380C Green 1, 2 RA1414 For VdS only = 155CF/680C Norbulb and 1/2 [12.7mm] adjustment. /1' ,LJUS1FIT Figure 1 Installation Aid A protective cap is included for use during installation. Important: The F1FR 56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR 56 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR 56 Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1FR 56 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for installing Fl FR 56 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprin- klers. The Model Fl FR 56/ CCP Concealed Sprinkler uses the ½" orifice, ½" NPT (R1/2), 135°F (57°C), 155°F (681C), 175°F (79°C) or 200°F (93°C) Model F1FR 56 Pendent Figure 2 Sprinkler with a threaded Model CCP cup which is fac- tory attached to the sprinkler. The assembly is complet- ed by the installation of the attractive, low profile, 135°F (57°C) or 165°F (74°C) rated Model CCP push on cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two cover plate assemblies provide either ½" (13mm) or /16" (8mm) of cover adjustment. Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2 /8" (67mm) diameter hole is cut in the ceil- ing, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprinkler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other con- cealed cover plate/cup assembly with the Model F1FR 56 Pendent Sprinkler or the use of the Model CCP Con- cealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and ap- provals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0 OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High " 1 141 1 286 1 225°F (107°C) I Blue Not available for recessed sprinklers. I Escutcheon Data (1) Escutcheon "A" Faceof Fitting to Model Approvals Adjustment INmension Ceiling or Wall Fl 1.3,4 Max Recess 1W (38.1mm) /E' - Mn Recess 3/4" (19.lrmi) (5rrirn - 24rwn) F2 1,2.3 ,4 Max Recess 1 ./' (3B.1 MM) 3/-.67- lb Min Recess 1" (25rrrn) (5mm - 17rmi) J) Push wv 1 4 Max Recessed /16 (llrrrn) 172 (38.1rrin) Thread-off Min Recessed I Is (24rr1n) 1' (254am) SIN: RA1435 - cULus and FM permts use with Fl or F2 escutcheons for light hazard only. Maintenance The Models Fl FR 56 and Fl FR 56 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate Bronze Brass Chrome Plated Chrome Chrome White Polyester Plated White Coated ON White Painted SpeciP Application Finishes Sprinkler Escutcheon Cover plate Bright Brass ' Bright Brass Bright Brass Black Plated Black Plated Satin Black Paint (2) Black Paint Oft White Oft White (2) Off White Black Paint Satin Chrome Satin Chrome Black Plated (" Other finishes and colors are available on special order. Consult the factory for details. (2) cULus Listed only. 131 200OF(93°C) maximum. ,41 cULus listed "corrosion resistance" applies to SIN Numbers RA1425 (Upright) and RA1414 (Pendent) in standard black or white. ' FM Approvals finish as Polyester coated" applies to SIN Number RA1414 (Pendent) in standard black or white. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model F1FR 56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 5. The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by IeIiabk ®Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A 02/10 PIN 9999970300 Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges ldentification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years. and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. As i (5-b i sl Fig. 25 - Surge Restrainer c®usLISTED Size Range - One size fits 3/4" thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed pall when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 1 It ; 1/ <• OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 v.iww.tnkn.,nm Fig. 200 - "Trimline" Adjustable Band Hanger C® 115 LISTED Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON. Order By - Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 2/8 400 11 3/4 3/8 8mm or 10mm 31A 21h 400 11 1 3/8 8mm or 10mm 33A 25A 400 12 11/4 3/8 8mm or 10mm 3W4 2/8 400 13 1½ 3/8 8mm or 10mm. 3/8 2/8 400 14 2 3/8 8mm or 10mm 41h 3 400 15 21h 3/8 10mm 55A 41/8 600 27 3 3/8 10mm 5/8 4 600 29 3½ 3/8 10mm 73A 51/4 600 34 4 3/8 10mm 7% 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 6V4 1250 73 8 1/2 12mm 131/8 8V4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 wwwtnIcn.,nm 114' 8002957 GST 100 1/4 x1" 114' 8003957 GST 200 1/4 x 2" 1/4' 8004957 GST 300 1/4 x 3" 3/8" 8006957 GST .75 1/4 x 314' 318" 8007957 GST 10 114 x1' 3/8" 8008957 GST 20 114 x 2" 4. 3/8' 8068925 GST 20-SS 114 x 2" 4. 3/8" 8009925 GST 25-380 3/8 x 2-112" 4. '? 318' 8010957 GST 30 114 a 3'- 318" 8069925 GST 30-SS 1/4 a 3' 3/8" 8011925 GST 40 1/4x4' 3/8" 8012925 GST 60 1/4x6' 1/2" 8013925 GST2 1/4x2" 'c.. 210 (7/16" OSB) 670 (3/4' Ply) - 1760 (Fir) 2060 (Fir) 564 (314" Ply) 210 (7116" OSB) 300 670 (3/4" Ply) 1760 (Fir) 850 1760 (Fir) 850 2113 (Fir) 1500 2060 (Fir) 1500 2060 (Fir) 2180 (Fir) 2230 (Fir) 1760 (Fir) 25 125 25 125 25 125 25 125 25 125 - 1475 25 125 25 125 25 125 1475 25 125 #14 Black 25 125 Nut Driver Part #8113910 25 125 25 125 - 41 25 125 I AsiG-bi-sot Product Features 'No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. "Made in the U.S.A. iii 1/2' e01423 8015925, GST 2.5-380 318 x 2-1/2 GST3 1/4x2' zuj (Fir) 2275 (Fir) 25 125 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 1/7 - 8017925 GST6 114 a 6" 2230 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 IS.A.MMY . - - Jam :• . b 3/8" 8139957 SII-GST20 114x2' 1257 (Fir) 1050 1475 25 125 125 O &-" 3/8' 8141957 SH-GST30 114x3 1720 (Fir) 1500 1475 25 125 1 #14 Black Nut Driver 4 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling unlit nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4 \ (IS _USA MADC IN Note: When installing SWDR. follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Not less than 7 nominal width (1.112) up to 3-117 pipe: not less than 3'(2-1;21 nominal width 4'9 5 pipe 4 Minimum 2-117 from bottom for / ' ( . branch tines. M:nimurn 3 horn 1/ 1 / bottom for main lines. Exception: This 1! // / requirement shall not apply to2or / 1 thicker naing strips resting on top of I / steel beams, / - — Product Features No pre-drilling required. :41 Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. ComposiITruss Co c_ed ft -. . 'QMWM 0020M - 1/4' 8018957 SWG 100 1/4 xi" 622 (Fir) 25 125 1/4' 8019957 SWG 200 1l4x 2" 1725 (Fir) 25 125 3/& 8020957 SWG 10 114 xr 622 (Fir) 300 25 125 4 I 3/8' 8021957 SWG 20 114 2' 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 20-SS 1/4 x 2' 1725 (Fir) 850 25 125 #14 SW Red 318" 8022925 SWG 25.380 318 x 2.1/2' 2249 (Fir) 1500 25 125 Nut Driver L 3/8' 8023925 SWG 30 114 x 3" 1884 (Fir) 25 125 Part #8114910 INSTALLATION STEPS -U PM INTO WOOD & STEEL: IINSTALTION STEPS -Lj INTO WOOD & STEEL Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. 1. Insert the appropriate nut driver into a 3/8 or 1/2p0r1ab1e drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill 2. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS. stop drill and remove. 3. When the nut driver spins free on the SAMMYS. stop the drill and remove. The SAMMYS is now ready to receive 114",3/8 1/2" or metric all thread rod, bolt stock. (The 1/2' requires the #14S W red nut driver) 4. The unit is now ready to receive 1/4 3l8ormetric all thread rod or bolt stock. Note: When installing DSTR, follow the above instructions. then add retainer nut and torque to 20 foot lbs. for maximum pullout in putlin steel. 2 MK ~ I I 119wInw, SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the Overcomes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. CIoE CtoE - I C to E I CluE t. NOMINAL SIZE IN. I END to END IN.... IAPPR OX.I WEIGHT EACH Lbs.•: 11/4 3.75 2.0 1 1/2 3.75 2.2 2 3.75 3.0 21/2 3.75 5.0 3 4.25 7.1 4 5.00 11.9 5 5.25 17.1 6 6.50 27.5 8 7.75 47.0 10 9.00 68.0 12 10.00 107.0 JiL GROOVED FITTINGS! MECHANICAL TEES 0 * <~> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 ?,R®PIPEPRODUCTS Ni N2 N3 N4 GxMPT GxB GxG GxH ADAPTER NIPPLES NOMINAL SIZE IN. I END to END IN. WEIGHT EACH Lbs. 1 3.00 0.40 1114 4.00 0.80 1 1/2 4.00 0.90 2 4.00 1.20 21/2 4.00 1.90 3 4.00 2.50 4 6.00 5.50 5 6.00 7.40 6 6.00 9.50 8 6.00 14.20 10 8.00 27.00 12 8.00 33.00 SW = Segmentaly welded steel (d) = Ductile iron Model MT-3 & MT-9 Mechanical tee serves the same function as MT-1 & MT-8 but uses a steel electro plated u-bolt to save space and for easier installation in tight places. It is ideal for direct connections with sprinkler heads and drop nipples. HOUSING: Ductile iron ASTM A536 grade 65-45-12. COATING: Zinc electroplated U - BOLT: Carbon steel SAE grade 2, zinc plated. NUT: Carbon steel ASTM A194, zinc plated. GASKET: EPDM (-30 ... F to + 230.. .F) THREADS: MT-3 NPT per ANSI/ASME BI.20.1 MT-9 British standard parallel (BSP) per BS21 NOMINAL SIZE IN. MAX. WORKING P.5.1.1 HOtE SIZE IN. MT-9 aim 'ZSIONS.InC',--- APPROX. WEIGHT EACH Lbs A I C 0 K 1 114. 112 300 1.19 2.14 1.64 3.50 1.21 2.25 0.03 1 114. 314 300 1.19 2.14 1.64 3.50 1.21 2.25 0.87 1114. 1 300 1.19 2.27 1.61 3.50 1.21 2.25 1.06 1 112. 112 300 j 1.19 2.26 1.76 3.50 1.33 2.25 0.83 1 112.314 300 1.19 2.26 1.76 3.50 1.33 2.25 0.87 1112 x 1 300 1.19 2.39 1.73 3.50 1.33 2.25 1.06 2. 112 300 1.19 2.51 2.01 3.75 1.56 2.25 0.87 2. 314 300 1.19 2.51 2.01 3.75 1.56 2.25 0.94 2.1 300 1.19 2.64 1.98 3.75 1.56 2.25 1.09 2 112. 112 300 1.19 2.76 2.26 4.25 1.81 2.25 0.89 2 112. 314 300 1.19 2.76 2.28 4.25 1.81 2.25 0.98 2112. 1 300 1.19 2.88 2.22 4.25 1.81 2.25 1.14 3 O.D.x112 300 1.19 2.82 2.32 4.25 1.88 2.25 0.89 3 0.0.014 300 1.19 2.82 2.32 4.25 1.88 2.25 0.98 3 O.D. s1 300 1.19 2.95 1 2.29 4.25 1.88 2.25 1.14 Page 12 MECHANICAL TEES STAR®PIPEPRODUCTS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Mechanical branch connections for reducing branch outlets without welding. The MT-1 is a bolted saddle type fitting with NPT female threaded outlets. Design assures superior sealing, full pipe support, excellent stability and easy installation iTHREADED MECHANICAL BRANCH111 NOMINAL SIZE IN. 1ULorFMMAX.1 WORKING P.S.I./ HOLE DIA. +i25/-0.0 IN. ' NUTS/BOLTS (INCH) QTY. SIZE ' DIMENSIONS.Inch/r.m APPROX.- WEIGHT EACH Lbs. A B C 0 E 2x1 300 1.50 2 318x2 2.62 1.58 4.62 2:47 1.96 1.70 20114 300 1.75 2 318x2 2:62 1.58 4.62 2.47 1.94 1.70 20 1/2 300 1.75 2 318x2 2.62 1.58 4.62 2.86 1.94 1.70 2 112x1 300 1.50 2 112x2 314 3.12 1.83 5.56 3.38 2.46 3.60 2112x1114 300 200 2 112x23/4 312 183 556 338 244 360 2 112x1 112 300 2.00 2 112x2 3/4 3.12 1.83 5.56 3.38 2.44 3.60 3x1 300 1.50 2 112x2 3/4 3.44 2.15 6.25 3.91 2.78 3.80 3x1 1/4 300 2.00 2 1/2x2 314 3.44 2.15 625 3.91 2.76 3.80 3x1 1/2 300 2.00 2 1/2x2 3/4 3.44 2.15 6.25 3.91 2.76 3.80 3x2 300 2.50 2 1/2x2 3/4 3.44 2.15 6.25 3:91 2.74 4.40 3 1/2x2 300 2.50 2 1/2x2 314 3.88 2.46 6.62 3.92 3.18 4.60 4x1 300 1.50 2 1/2x2 3/4 4.00 2.65 7.25 3.83 3.34 4.60 4x1 1/4 300 2.00 2 1/2x2 3/4 4.00 2.65 7.25 3.83 3.32 4.60 4x1 1/2 300 2.00 2 1/2x2 3/4 4.00 2.65 7.25 3:83 3.32 4.60 4x2 300 2.50 2 112x2 3/4 4.00 2.65 7.25 4.52 3.30 4.80 4x2 1/2 300 2.75 2 1/2x2 3/4 4.00 2.65 7.25 4.52 3.07 5.40 5x1 1/2 300 2.00 2 5/8x4 4.75 3.18 8.30 3.83 4.07 6.93 5x2 300 2.50 2 5/8x4 4.75 3.18 8.30 3.83 4.05 7.48 5x2 1/2 300 2.75 2 5/8x4 4.75 3.18 8.30 3.83 3.82 7.61 6x1 1/2 300 2.00 2 5/8x4 5.12 3.71 9.38 3.86 4.44 7.50 6x2 300 2.50 2 5/8x4 5.12 3.71 9.38 4.42 4.42 8.00 6x2 1/2 300 2.75 2 5/8x4 5.12 3.71 9.38 4.42 4.19 8.00 8x2 300 2.50 2 3/4x4 1/4 6.25 4.83 12.32 4.48 5.55 11.60 All sizes may be used as mechanical crosses. Threads are NPT per ANSI/ASME B1.20.1 * Contact Star Pipe Products for actual listings on specific pipes Page 13 MECHANICAL TEES IPDL1TS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Mechanical branch connections for reducing branch outlets without welding. The MT-2 is a bolted saddle type fitting with grooved outlets. Design assures superior sealing, full pipe support, excellent stability and easy installation - C - C - -0- j 4GROOVED M ECHA NICAL BRANCH TE NOMINAL SIZE IN. ' UL0rFMMAX. WORKING P.S.I./ ' HOLE DIA. +.125/-0.0 IN. ' NUTS/BOLTS (INCH) QTY. SIZE ' DIMENSIONS-Inch/ APPROX. WEIGHT EACH Lbs. A B C D 3 O.D.xl 1/4 300 2.00 2 1/2x2 3/4 3.18 1.89 5.69 3.38 3.60 3 0.D.x1 1/2 300 2.00 2 112x2 3/4 3.18 1.89 5.69 3.38 3.60 3x1 1/2 300 2.00 2 112x2 3/4 3.44 2.15 6.25 3.91 3.80 3x2 300 2.50 2 1!2x2 3/4 3.44 2:15 6.25 3.91 4.40 4x1 1/2 300 2.00 2 112x2 3/4 4.00 2.64 7.25 3.83 4.60 4x2 300 2.50 2 1/2x2 3/4 4.00 2.65 7.25 4.52 4.80 4x2 112 300 2.75 2 1I2x2 3/ 4.00 2.65 7.25 4.52 5.40 4x3 O.D. 300 2.75 2 112x2 3/4 4.00 2.65 7.25 4.52 7.60 4x3 300 3.50 2 1/2x3 1/4 4.13 2.65 7.25 5.12 7.60 5x2 300 2.50 2 5/8x4 4.75 3.18 8.30 4.52 7.19 5x2 1/2 300 2.75 2 5/8x4 4.75 3.18 8.30 4.52 7.19 5x3 300 3.50 2 5/80 5.00 3.18 8.30 5.12 7.90 6x1 1/2 300 2.00 2 5/8x4 5.12 3.71 9.38 3.86 7.50 6x2 300 2.50 2 5/8x4 5.12 3.71 9.38 4.42 8.00 6x2 1/2 300 2:75 2 5/8x4 5.12 3.71 9.38 4.42 8.00 6x3 O.D. 300 2.75 2 5/8x4 5.12 3.71 9.38 4.42 9.70 6x3 300 3.50 2 5/8x4 5.25 3.71 9.38 5.62 9.70 6x4 300 4.50 2 5/8x4 5.38 3.71 9.38 6.50 13.60 6.5 O.D.x1 1/2 300 2.00 2 5/8x4 5.12 3.65 9.25 3.86 7.50 6.5 O.D.x2 300 2.50 2 5/8x4 5.12 3.65 9.25 4.42 8.00 6.5 O.D.x3 O.D. 300 2.75 2 5/8x4 5.12 3.65 9.25 4.42 8.00 6.5 O.D.x3 300 3.50 2 5/8x4 5.25 3.65 9.25 5.62 9.70 6.5 O.D.x4 300 4.50 2 5/8x4 5.38 3.65 9.38 6.50 13.60 8x2 1/2 300 2.75 2 3!4x4 1(4 6.25 4.83 12.32 4.48 11.60 8x3 300 3.50 2 3/4x4 1/4 6.50 4.83 12.32 5.68 12.60 8x4 300 4.50 2 3/4x4 1/4 6.38 4.83 12.32 6.59 15.30 All sizes may be used as mechanical crosses. Outlet branch is machined per standard cut groove specification * Contact Star Pipe Products for actual listings on specific pipes Page 14 MECHANICAL TEES STAR®PIPEPRODUCTS là <S> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Mechanical branch connections for reducing branch outlets without welding. The MT-8 is a bolted saddle type filling with BSP female threaded outlets. Design assures superior sealing, full pipe support, excellent stability and easy installation. a! C7~~W4 t 1-111771 I M T -8 *1 a THREADED MECHANICAL BRAN T EE I NOMINAL IULorFMMAX.I HOLE NUTS/BOLTS ' DIMENSIONS -Inch/urn 1APPROX. I SIZE WORKING DIA. (INCH) I WEIGHT IN. P.S.I./ +.25/-0.0 QT Y. SIZE A B C D E EACH IN.. Lbs..,. 2x1 300 1.50 2 318x2 2.62 1.58 4.62 2.47 1.96 1.70 2x1 1/4 300 1.75 2 3/8x2 262 1.58 4.62 247 1.94 1.70 2x1 1/2 300 1.75 2 3/8x2 2.62 1.58 462 2.86 1.94 1.70 3ODx1 300 150 2 1/2x23!4 318 189 569 338 246 360 3 O.D.xl 1/4 300 2:00 2 1!2x2 3/4 3.18 1.89 5.69 3.38 244 3.60 3 O.D.x1l 1/2 300 2.00 2 1/2x2 3/4 3.18 1.89 5.69 3.38 2.44 3.60 • ..: . 3x1 300 1.50 2 112x2 3/4 3.44 2.15 6.25 3;91 2.78 3.80 3x1 1/4 300 2.00 2 1/2x2 3/4 3.44 2.15 6.25 3.91 2.76 3;80 3x1 1/2 300 2.00 2 1/2x2 3/4 3.44 2.15 6.25 3.91 2:76 3.80 3x2 390 2.50 2 1/2x2 3/4 3.44 2.15 6.25 3:1 274 4.40 4x1 300 1.50 2 1/2x2 3/4 4.00 2:65 7.25 3:83 3.34 4.60 4x1 1/4 300 2.00 2 1/2x2 3/4 4.00 2.65 7.25 3:83 3.32 4.60 4x1 1/2 300 2.00 2 1/2x2 3/4 4.00 2.65 7.25 3.83 3.32 4.60 4x2 300 2.50 2 1/2x2 3/4 4.00 2.65 7.25 4.52 3.30 4.80 4x3 O.D. 300 2.75 2 1/2x2 3/4 4.00 2.65 7.25 4.52 3.07 5.40 6 O.D.x 11/2 300 2.00 2 5/8x4 5.06 3.65 9.25 3:86 4ç2 7.50 6 O.D.x 2 300 2.50 2 5/8x4 5.06 3.65 9.25 4.42 4.32 8.00 6 O.D.x3 O.D. 570-t 2.75 2 5/8x4 5.12 3.65 9.25 4.42 4.19 8.00 All Sizes may be used as mechanical crosses. Threads are British standard paralled jointing per BS 21. * Contact Star Pipe Products for actual listings on specific pipes Page 15 I I I I a 'M I I Fffj I I :) - - -- -.. %•,- s--- - —I. - '-, - v--- .- - t - [& Sched. em10@/Sc%ed i e- I )® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-1O/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (lY"- 8") pipe and Sch-40 (1"- 2V.,") pipe have passed the same thorough lab testing as our other listed pipe products. and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. f ' 0 Specificationsi NPS Nominal I.D. WI. WI. (1120 Filled) PcW WI/Lift (21') WI/Lift (24') Wt/lift (25) In. mm In; mm Lbs/Fl; Kg/rn Lbs/Fl: Kg/rn Lift Lbs: Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2.470 2,822 2.940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1½' 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2.628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2W 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WI/Lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1.252 1W 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2' 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21h" 2.635 3.530 5.89 30 2,224 2,542 2.648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2.057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 22558 2.665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1.053 8" 8.249 16.490 40.15 7 2,424 2,770 2.885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule-I 0/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: NXIelded Outlets Hydrostatic Pressure Side \Va1l Rupture Vibration Test tLICQ/Flow Control ç:) allied TUBE & CONDUIT @ <S> @ Listed Approved Listed 16100 S. Lathrop• Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3