3428 VIA MERCATO; ; FA140146; Permit
5/2/24, 3:52 PM FA140146 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA140146 Job Address: 3428 VIA MERCATO Permit Type: FALARM Parcel No: 2230507200 Lot #: 0 Reference No.: Status: APPROVED Applied 10/21/2014 Approved: 10/27/2014 Issued: 10/27/2014 PC #: Inspector: Project Title: BANK OF AMERICA INSTALL NEW FIRE ALARM SYSTEM IN A NEW ONE-STORY SPOINKLERED B OCCUPANCY BANK BUILDING. SPINKLER SYSTEM IS MONITORED BY NEW FIRE ALARM PANEL. INSTALL A NEW SMOKE DETECTOR AT FACP AND PULL STATION ANNUNCIATOR AND HORN/STROBE AT FRONT ENTRY. INSTALL NEW CELL COMMUNICATOR FOR MONITORING OF SYSTEM. SYSTEM IS MONITORED BY A CENTRAL STATION. Applicant: RIVER FIRE & SECURITY INC. 8920 ACTIVITY RD STEJ SAN DIEGO, CA 858-752-6250 Owner: PROPERTY DEVELOPMENT CENTERS L L C C/O SAFEWAY INC 5918 STONERIDGE MALL RD PLEASANTON CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 289 0 289 0 about:blank ill II (!FP-5Oi MEA 429-92-E Vol. XVI P' SILENT Farenhyt FA140146 KNIGHT by Honeywell Intelligent Fire Alarm Control Panel PV-501 IFP-50 is an analog/addressable fire control panel (FACP). IFP-50 has a single line circuit (SLC) loop for connecting addressable detectors and modules and has two notification appliance circuits that can be programmed for notification outputs or auxiliary power. IFP-50 also has a built-in dual line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation and pre-trouble maintenance alert. IFP-50 supports a variety of other devices that can be added to the system such as RA-100 o( RA-1000 remote annunciator 5824 serial/parallel printer interlace module (for printing system reports), and 5496 intelligent power module, and SD or lOP devices. Features (Built-in support for up to 50 SD deviiéor 50 lOP detectors and 50 1DPitdUles Uses standard wire—no shielded or twisted pair required Built-in digital communicator for remote reporting of system activity and system programming Central station reporting by point or by zone Jumpstart® auto-programming Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC • Distributed, intelligent power Built-in synchronization for appliances from AMSECO, Gente, Faraday, System Sensor, and Wheelock® Sensor sensitivity settings and day/night sensitivity setting and automatic drift compensation Notification circuits can be configured as 1 Class A (Style Z), 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in annunciator with a backlit 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 interlace for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 24 VOC Two built-in Form C programmable relays rated at 2.5 amps at 24 VDC SLC device locator can be used to locate a single or multiple devices on a SLC loop • System automatically performs detector sensitivity test 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable patterns • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite (SKSS) Improvements in SKSS deliver five times faster upload/downloads Non volatile event history stores up to 1000 events 125 software zones and 125 output groups Agency Listings 2.5 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 7 amp hours). Programmable date setting for Daylight Saving Time Compatibility The IFP-50 SLC supports multiple device types of the same protocol: SO lOP You cannot mix SD and lOP devices on a FACP. However, any combination of addressable devices of the same protocol can be used on the lFP-50. Specifications Physical Dimensions: 12.75W x 15.2"H x 3.4"D (36.8 W x 62.9 H x 9.8 0 cm) Weight: 11.5 lbs. (5.2 kg) Color: Red P/N 350328 Rev J © 2014 Honeywell International Inc. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical Primary AC: 120 VRMS @50/60 Hz, 2.7A Total Accessory Load: 2.5A @ 27.4 VDC power-limited Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet Larger capacity batteries can be housed in RBB accessory cabinet Notification Appliance Circuits Two circuits that can be programmed individually as: Notification Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Auxiliary Power Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Indicator Lights Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced Trouble (Yellow): Flashes when a trouble condition exists; solid when trouble silenced Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared Power (Green): Flashes for AC failure; solid when power systems are normal Telephone Requirements: FCC Part 15 & Part 68 approved Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listing; CSFM 170-0559: 144; MEA 429-92-E Vol XVI Approved Releasing Solenoid Manufacturer Part Number Rating Asco T8210A107 24 VDC, 2.5A Ordering Information (50) SBUS Accessories RA-100 Remote Annunciator. Similar in operation and appearance to FACP annunciator. f'i0O0] Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. 5496 Intelligent Power Module. 6 amp power module that provides four additional power limited notification appliance circuits. 5824 Serial/Parallel Printer Interface Module. Provides one parallel and one RS-232 serial port for connecting a printer to IFP-50. 5880 LED I/O Module. Provides 40 LED outputs, eight normally open dry contacts inputs and one piezo output. 5865-3 & 5865-4 LED Fire Annunciators. Provides 30 programmable LED outputs and a piezo sounder. 5883 Relay Interlace Board. Provides 10 general purpose Form C relays. Used with 5880. SD and lOP Devices See the specification sheets listed below for a complete listing of the SD and IDP devices. 350360 SD Devices data sheet 350361 Intelligent Device Protocol (lDP) Devices data sheet Miscellaneous Accessories 5650/5651 Silent Knight Software Suite. Provides programming, upload/download, and event reporting. Order 5650 for PC parallel port compatibility or 5651 for PC USB port compatibility 5670 Silent Knight Software Suite. Provides facility monitoring RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"Wx 10" H x6" D(406 mmWx254 mm H x 152 mm D) SP-TR Small panel trim ring. Use to flush mount Asco 8210G207 24 VDC, 2.5A the panel. 16.975" H x 14.630" W. D SILENT This document is not intended to be used for installation purposes. We by to keep our _______________ product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT product all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical support, please call 800-446-6444. www.farenhyt.com Assembled In the U.S.A. Farenhyt Remote Annunciator (RA-1000) The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of the lFP-1000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence RS-485 interface to panel Operation and appearance is identical to IFP-1000 built-in annunciator Install up to 12 RA-1000s per lFP-1000/ECS or lFP-100/ECS Install up to eight RA-1000s per lFP-50 Support for simultaneous use of multiple RA-1000s On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Available in red or light gray Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved MEA DSILENT KNIGHT by Honeywell Agency Listings MEA &429-92-E€VoHX APPROVED *_ • '.--a- .. - • woo , 1 all CA RA-1000 Installation The RA-1000 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. Compatibility The RA-1000 is compatible with the following FACPs: lFP-I000ECS Emergency Communication System with Fire Alarm Control Panel IFP-1 OGECS Emergency Communication System and Fire Alarm Control Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel FP-50 Intelligent Fire Panel) PIN 350071 Rev E Copyright © 2014 Honeywell International Inc. IFP-i 000 FACP RA-1000 RA-1000 RA-1000 • U 3 3 3 izutJ4) V V Up to 12 RA-1000s per system for IFP-1000, • 80-character backlit LCD display IFP-I000ECS, IFP-100 & IFP-100ECS (4 lines with 20 characters each) Up to 8 RA-1000s per system for IFP-50 • Wiring lengths up to 6000 ft. from the control panel Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5" (3.8 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color RA-1000R: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC (Standby Current: 20 mA max) (Alarm Current: 25 mA) Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals NFPA72 ULListed; CSFM 7170-0559:135; MEA429-92-E Vol. IX; FM Approved Ordering Information RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring. For surface mounting. 5860TG Gray Trim Ring. For surface mounting. FlexputTM is Trademark of Silent Knight Jumpslart® is a Registered Trademark of Silent Knight ] SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800.446.6444. www.farenhyt.com Assembled in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0144 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: (Models *IFP..50)and *5700 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: IFP-50, 5700 Control Units 7628 EOL Resistor 5860/5860RtA-1O0j Annunciator) 5897 Power Supply 5496 *Notification Power Expander 5824 Serial/Parallel Interface 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interlace Board SD500-LIM Line Isolation Module 5D505-618 Isolation Base RA-1 00 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. Rev 10-3-08MA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (June 30, 201) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division ng:o. t7165-055944 rage 2 of 2) NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev 10-3-OBMA This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not IN an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (Listing ExpJj (June 30, 2015) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division A Tyco Iniornaliorial Company Difference: Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an IP • Automatically switches to 2G (EDGE/GPRS) if 3G service is 3G technology from DSC! not available Compatible with control panels that communicate using the Contact ID format Full event reporting 4 on-board inputs 4 on-board outputs (open collector) SIM card (included) Activation and initialization via automated telephone activation system (VRU), web-user or mobile interface provided by C24 Communications PTM (Panel Transmission Monitor) switches from PSTN to cellular on unsuccessful communication attempts Compatible with Sur-Gard® System I/I VII VIV monitoring Station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed 0 CSFM listed The 3G3070CF connects the alarm control panel to the HSPA network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System VIVIII/IV). The 3G3070CF uses the HSPA network to ensure low- cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID format. The 3G3070CF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 Edition. It can be used in Are Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DAd). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G3070CF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G3070CF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the HSPA network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the HSPA network to the monitoring station. In instances where the control panel does not support Contact ID, the 3G3070CF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Dec A Tyco /nlornaional Company Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-GardO System Vll/lllIl\. Activating & initializing the unit Activating and initializing the 3G3070 can be done using the automated telephone activation system (VRU), mobile interlace or web-user interlace provided by CONNECT 24. No special tools are required. UL Listing The 3G3070CF is UL listed under File S4019, Usting guide UO)O(, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator the 3G3070CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a backup communicator the 3G3070CF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G3070CF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. Specifications Dimensions ................................................ 11-1/2" x 10" x 3" (29.2 cm x 25.4 cm x 7.62 cm) Input Voltage.............................................................120 VAC Current Draw .............................................................. 300 mA Operating Environment ................0° to 48° C (320 to 120° F) Weight...........................................................12.8 lbs (5.8 kg) Ordering Information: 3G3070CF-USA ..... Universal Wireless Commercial Fire Alarm Communicator (U.S. ModeVSlM Card Included) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Q-1273:014 b) Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: DigitaI Security Controls95 I'geIandAve, Toronto, Ontario M6A 1Y7 Canada Contact Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: (Model 3G3070-CF,)RF communicator (GSM-GPRS or 3GIHSPA network) signaling device. It intended for use as a standalone communication technology)(standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. It is used for central station fire and burglar alarm system communication, which employs a GSM-GPRS or 3G/HSPA (cellular) communication as its signaling medium. This product is to be connected to a listed control panel in accordance with the installation instructions provided with the Model 3G3070-CF transceiver. A Motorola radio, Model 1-124, connects to an interface board, Model UA595, to form a Model 3G3070-CF communicator, which is intended to be installed at each protected premise. The Model 3G3070-CF is housed in its own metal enclosure and can connect to any separately listed control unit through a telephone line connection or using its inputs connected to dry contacts outputs from the fire alarm control panel for alarm, supervisory, or trouble transmissions. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 V, 50160 Hz, 0.3 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 02.09.12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (ypngExpJjj (June 30, 20151 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division D SILENT (Addressable Photoelectric KNIGHT (Smoke Detector 0 by Honeywell Detect smoldering fires quickly and get help fast with lntelliKnight photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog / Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsiM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 1741 VOC Current Consumption: (Standby. (.55 mA) (larm:) (.55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4 Square, 4 OCT. Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: S0505-6AB (Sold Separately) SD505-61B S0505-6RB SD505-6SB Model SD505-APS Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. 10 Diameter = 5-15/16° - P1 Diameter = 3-15116" 0 ME Height = 2 inches, including base Model SD505-6AB Detector Base (front view) Model SD505-APS Detector Head (front view) This document is not intended to be used for installation purposes. We by MADE IN AMERICA SILENT to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent FORM# 350225 Rev D by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 © 2010 Honeywell International Inc. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7272-0559:0129J Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: (SILENT KNIGHT SECURITY755Meridian Circle, Maple Grove, MN 55369-4927 Contact Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: [Model SD505-APS analog addressable photoelectric type.—smoke detectorjwith model SD505-4AB and 50505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:0149 *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (ytigExp/r (June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division (SD500-PS)and SD500-PSDA Addressable Pull-Station lntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an lntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed CSFM listed ADA compliant Key reset (Same key as Silent Knight enclosures) Surface mount back box available Terminals - accept up to 14 gauge wire Corrosion-resistant gold-plated contacts. Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC taycnt: (rnA (Alarm Current) () All-AfAn K?A4Z .-di• '. ~61 SD500-PS Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB c SILENT KNIGHT SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings. Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. rAcP I' o Wiring bier I II I Mounting to Single Gang Electrical Box Mounting to Options Surface Mount Box SD500-PSDA Installing SD500-LK Dimensions Elecirloal Dw mm be at k" l-H2D,p DSILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369.4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM 350342, Rev. 09/03 Copyright © 2003 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7150-0559:0136 Page 1 of 1 CATEGORY: (7150 —)FIRE ALARM PULL BOXES LISTEE: [SILENT KNIGHT SECURlTY7öjMeridian Circle, Maple Grove, MN 55369-4927 Contact Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model PS-SKSA an4 SD500-P1re alarm pull boxes]efer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units. For indoor use only. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. Updated 08-29-2011 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed g'-\"; the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 fingExpJJ (June 30, 2015] Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell (SD500-AIM)& SD500-MIM Addressable Input Modules lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The S0500-AIM and SD500-MIM are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor SD500-AIM supports Class A (Style 0) or Class B (Style B) contact monitor wiring SD500-MIM support for Class B (Style B) contact monitor wiring Attractive ivory cover plate with the 5D500-AIM Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications (standby Curren 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; (5 mA for each additional device) Line Resistance: 501 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9"W x 4.9" H x 1" 0 (12.4Wx 12.4 Hx2.5Dcm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" D (3.8Wx6.4 H x 1.8 0cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing SDSOO.AIM SD500-MIM Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559:132 MEA429-92-E Vol. IX FM Approved for use with the 5820XL ç:)O O,t -' 0 SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Compatible FACPs FACPs 5820XL 5820XL-EVS 5808 5700 Ordering Information S13500-AIM Input Module Addressable input module with ivory cover plate. S0500-MIM Input Module Addressable mini input module. D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev. F subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc by Honeywell 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446.6444. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-0559:0132) Page 1 of 1 CATEGORY: (3O)FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: (SILENT KNIGHT SECURITY7O)Meridian Circle, Maple Grove, MN 55369-4927 Contact Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model SD500-ARM RelaytModule and SD500-AIM,JSD500-MIM Addressable Input Modules*. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MlM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and ULlabel. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 LLisfing 30, 2015) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division F I R i I SYSTEM $ SENSOR Indoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAler!' Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150. 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNAlING ®4>MEA LISTED APPROVED 54011 (ChMea.flcrnstrobes.hozns) 23572 S5512 (8501,e3) approved MEA452.05.E 7125-1653:186(indoorstmbes) 7125-1653:189(Iio,n Uobes. c141nes1r04es) 7135-1053:189 (horns. chines) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17,8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit'" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75. 30, 75,95 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21,8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range io to 93% non-condensing Strobe Flash Rate i flash per second Nominal Voltage Regulated 12 DCIFWR or regulated 24 DCIFWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (Including lens) 5.6-L x 4.7W x 2.5D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6% x 4.7W x 1.30(142mm Lx 119 mm W x 33 mm D) Wall-MountTrim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7% x 4.8W x 0.350 (145 mm Lx 122 mm W x 9 m D) Notes; Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S. PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Cuffent Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-175 Volts A.1TL;1lt 16-33 Volts - Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 _IW- IITI 8-17.5 Volts 16-33 Volts DC 15 15/75 15175 30 75 95 110 115 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low UL Max. Current Draw (mA 132 RMS), 2 -Wire 154 Horn Strobe, 80 High Candela 90 105 Range (135-185 cd) 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7? Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 86 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 31 Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard Cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Fled, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, 'FUEGO' P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red. Plain 2W) (i wt5ii P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High Cd, White P2WH-P 2-Wire Horn Strobe, High Cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High Cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard Cd, Red, Plain SR-SP Strobe, Standard cd, Red, 'FUEGO" Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no 'FIRE" marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. 'High cd' refers to strobes that include 135, 150, 177. and 185 Candela settings. "STEM 3825 Ohio Avenue • St. Charles, IL 60174 W014 System Sensor. L$ SEAlsoR Phone: 800-SENSOR2 • Fax: 630-377-6495 1w curse pedret dO,nratót, eg ten of th data beet www.systemsensor.com AVD51o20I • 1114 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17125-1653:0188) Page 1 of 1 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE:(System Sensor, Unincorporated)Div of Honeywell Intl lnc.3825 Ohio Ave, St Charles, IL 60174 Contact Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. (ModeljP2RjP2W,_2RH and P2WH E[mIStrobes)two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K' suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDCIRNR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as "horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes" can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15.11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (Listing Expires) (June 30, 2015) Authorized By: JAMES PA RSEG!A N, Program Coordinator Fire Engineering Division