HomeMy WebLinkAbout3440 VIA MERCATO; ; AS140217; Permit5/2/24, 3:54 PM AS140217 Permit Data City of Carlsbad Sprinkler Permit Job Address: 3440 VIA MERCATO Permit Type: SPRINK Parcel No: 2230507200 Lot #: 0 Reference No.: Permit No: AS140217 Status: ISSUED Applied 8/20/2014 Approved: 9/3/2014 Issued: 9/3/2014 PC #: Inspector: Project Title: CHASE BANK NEW COMMERCIAL FIRE SPRINKLER INSTALLATION• PER NFPA 13. Applicant: GUARDIAN FIRE PROTECTION 13941 E. IVANHOE ST GILBERT, AZ 480-797-9133 Owner: PROPERTY DEVELOPMENT CENTERS L L C C/OSAFEWAY INC 5918 STONERIDGE MALL RD PLEASANTON CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 202 0 202 0 about:blank Ill Fire -Fire Sprinkler Hy F Guardian Fire Protection Iopment, Inc. CHASE BANK Pagelj I General Project Data Report [General Data Project Title: Designed By: Code Reference: Client Name: Address: Company Name: Company Address: Phone: Building Name: Contact at Building: Address Of Building: CHASE BANK RR NFPA 13 GUARDIAN FIRE PROTECTION 361 E. IVANHOE ST GUARDIAN FIRE DESIGN 1911W. SAWTOOTH WAY 480-797-0873 CHASE BANK JODY ROBBINS 3440 VIA MERCATO Project File Name: Date: Approving Agency: Phone: City, State Zip Code: Representative: City And State: Building Owner: Phone at Building: City, State Zip Code: 1752-CHASE BANK - CARLSBAD CA. .fiw 7/9/2014 AHJ 480-962-9393 GILBERT, AZ RR SAN TAN VALLEY, AZ JP MORGAN CHASE BANK, N.A. CARLSBAD, CA LP!pJect Data - - - - Description Of Hazard: LIGHT HAZARD Sprinkler System Type: Wet Design Area Of Water Application: 1500 ft2 Maximum Area Per Sprinkler: 130 ft2 Default Sprinkler K-Factor: 5.60 K Default Pipe Material: DYNA-FLOW-10 Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 100.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: VIKING Model: VK300 Size: 1/2 Temperature Rating: 200 F Water Supply Test Data Source Of Information: GUARDIAN FIRE PROT Test Hydrant ID: Date Of Test: 6-22-14 Hydrant Elevation: 0 ft Static Pressure: (8280 psi Test Flow Rate: 1453.00 gpm Test Residual Pressure: 72.80_ L psi LA Calculated System Flow Rate: 40147 gpm Calculated Inflow Residual Pressure: 53.91 psi Available Residual Pressure At . System Flow: psi [Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.04 psi Number Of Active Nodes: 27 Number Of Active Pipes: 26 Number Of Active Sprinklers: 17 AREA #1 Minimum Desired Flow Density: gpm/1t2 Number Of Inactive Pipes: Number Of Inactiv.e..Sirink These pl,tins hate hecn reviewed toi ippteun compliance ill) the current applicable emides and iiid;irds in kirce in the jurisdiction. The owner or 4.01111 ,1001, nu uiuliie this I cviess in stippom of an application Cor a building pLruiiim srnh the express tiitdriaiiding that this res less in ni' was relic es the oss ncr or contractor or I heir protessiiim;ai engineer or ai'chimect Ilir smile responsmhihi for full compliance Willi said COtICS and standards. including the building code or for any responsihillv for deluciencies. errors. OlfllSSltSilS m, negligence in these plans Whether or m'ot noted in this review. Date: ft/i' !ICoMlENl) APIR( )VAI. 11 khCslMlNl) AlIPW )VAI.. AS d ITFl) e - Fire Sprinkler Hydraulics Calculation Program. . - :, Elite Softare Development, I ardian Fire Protection CHASE BA ert.AL85296 ... •... .,. Lha.S Pag iFireSprinkler Input INodeInPut Data Area Group Sprinkler Pressure Node Elev (ft) Non-Sprinkler Node Node Description Branch Dia KFactor (K) Estimate (psi) Branch Non- Flow (gpm) No. Branch Description 'in' Branch Len. Branch Stnd Stnd Fittings Branch Sprk Fittings (ft) KFactor (K) l 1 Sprinkler ---- 5.60 10.05 18.00 0.00 0.000 0.0 ---- 0.0 0.00 2 Sprinkler ---- 5.60 10.24 18.00 0.00 0.000 0.0 ---- 0.0 0.00 3 Sprinkler ---- 5.60 11.07 18:00 0.00 0.000 0.0 ---- 0.0 0.00 4 Sprinkler ---- 5.60 12.60 18.00 0.00 -- ---- 0.000 0.0 ---- 0.0 0.00 5 Sprinkler ---- 5.60 7.04 18.00 0.00 0.000 0.0 ---- 0.0 - 0.00 6 Sprinkler ---- 5.60 7.23 18.00 . 0.00 ---- 0.000 0.0 ---- 0.0 0.00 1 Sprinkler ---- 5.60 7.81 18.00 0.00 0.000 0.0 ,---- 0.0 0.00 8 Sprinkler ---- 5.60 8.93 18.00 0.00 0.000 0.0 ---- 0.0 0.00 Sprinkler ---- 5.60 11.17 18.00 0.00 0.000 0.0 ---- 0.0 0.00 I 10 Sprinkler ---- 5.60 7.30 18.00 0.00 0.000 0.0 ---- 0.0 0.00 11 Sprinkler ---- 5.60 7.50 18.00 0.00 I . ---- 0.000 0.0 ---- 0.0 0.00 12 Sprinkler ---- 5.60 8.10 - 18.00 0.00 0.000 0.0 ---- 0.0 0.00 13 Sprinkler ---- 5.60 9.26 18.00 0.00 0.000 0.0 ---- 0.0 0.00 14 Sprinkler ---- 5.60 11.58 18.00 0.00 -. ---- 0.000 0.0 ---- 0.0 0.00 15 Sprinkler ---- 5.60 14.11 18.00 0.00 - ---- 0.000 0.0 ---- 0.0 0.0 16 Sprinkler ---- 5.60 14.37 18.00 0.00 - ---- 0.000 0.0 ---- 0.0 0.00_ 17 Sprinkler ---- 5.60 15.47 18.00 0.00 0.000 0.0 ---- 0.0 0.00 18 No Discharge ---- N/A 18.86 15.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 Fire - Fire Sprinkler Hydraulics Calculation Prógrám - Guardian Fire Protection . LGilbert, AL 85296 A _L - Elite Sftware Development, In - .. CHASE BANK Pagej Fire Sprinkler Input Data - _1 .[Node Input Data (cont'd). Area Group Node Node Description Branch Dia No. Branch Description in / Sprinkler KFactor (K) Branch Len. (ft) Pressure Estimate (psi) Branch Stnd Fittings Node Elev (ft) Branch Non- Stnd Fittings (ft) Non-Sprinkler Flow (gpm) Branch Sprk KFactor(K) 19 No Discharge ---- 0.000 N/A 0.0 11.18 ---- 18.00 0.0 0.00 0.00 20 No Discharge ---- N/A 19.00 15.00 0.00 0.000 0.0 ---:- 0.0 0.00 21 No Discharge ---- N/A 11.59 18.00 0.00 0.000 0.0 ---- 0.0 0.00 22 No Discharge ---- N/A 19.63 15.00 0.00 0.000 .0.0 0.0 0 .00 23 No Discharge ---- N/A 15.47 18.00 0.00 0.000 0.0 ---- 0.0 0.00 24 No Discharge ---- N/A 21.02 15.00 0.00 0.000 0.0 ---- P0.0 .0.00 25 No Discharge ---- N/A 30.92 15.00 0.00 0.000 0.0 ---- . 0.0 0.00 26 Non-Sprinkler . ---- N/A 46.79 0.00 100.00 0.000 0.0 ---- 0.0 0.00 27 No Discharge ---- N/A 53.91 0.00 0.00 0.000 0.0 ---- 0.0 0.00 Elite Software Developme4inc.1, i[fri:Fire Sprinkler Hydraulicè Calculation Program I I Guardian Fire Proteàtion - . klt~~s - CHASE BANK I [Gilbert, AL85296 "-,... Page4 I PipeInput Data ' ..-. CFactor Be End End Nominal T e Fitting Nominal Fitting Total Node N d Pipe Description 0 e Diameter Groupat Length Length Length (gpm/inch- (inch) (feet) (feet) (feet) psi) 1 2 DYNA-THREAD NT 1.250 0 8.10 0.00 8.10 120 2 3 DYNA-THREAD NT 1.250 0 9.40 0.00 9.40 120 3 4 DYNA-THREAD NT 1.250 0 8.00 0.00 8.00 120 5 6 DYNA-THREAD NT 1.250 0 11.10 0.00 11.10 120 6 7 DYNA-THREAD NT 1.250 0 9.00 0.00 9.00 120 7 8 DYNA-THREAD NT 1.250 0 8.10 0.00 8.10 120 8 19 DYNA-THREAD NT 1.250 0 9.10 0.00 9.10 120 9 19 DYNA-THREAD NT 1.250 0 0.11 0.00 0.11 120 10 11 .DYNA-THREADNT 1.250 - 0 11.10 0.00 11.10 120 11 12 DYNA-THREAD NT 1.250 0 9.00 0.00 9.00 120 12 13 DYNA-THREAD NT 1.250 0 8.10 0.00 8.10 120 13 21 DYNA-THREAD NT 1.250 0 9.10 0.00 9.10 120 14 21 DYNA-THREAD NT 1.250 0 0.11 0.00 0.11 120 15 16 DYNA-THREAD NT 1.250 0 8.10 0.00 8.10 120 16 23 DYNA-THREAD NT 1.250 0 9.10 0.00 9.10 120 17 23 DYNA-THREAD NT 1.250 0 0.11 0.00 0.11 120 4 18 DYNA-THREAD NT 1.250 0 El 4.60 9.93 14.53 120 19 20 DYNA-THREAD NT 1.250 0 2T 3.00 13.24 16.24 120 21 22 DYNA-THREAD NT 1.250 0 21 3.00 13.24 16.24 120 23 24 DYNA-THREAD NT 1.250 0 21 3.00 13.24 16.24 120 18 _20 DYNA-FLOW-10 2.500 0 9.60 0.00 9.60 120 20 22 DYNA-FLOW-10 2.500 0 11.00 0.00 11.00 120 22 24 DYNA-FLOW-10 2.500 0 11.00 0.00 11.00 120 24 25 DYNA-FLOW-10 2.500 0 E 41.00 9.33 50.33 120 25 26 DYNA-FLOW-10 2.500 0 BC 15.00 32.66 47.66 120 26 27 PVC C-900 PRESSURE 4.000 0 5ETG 276.00 21.00 297.00 150 [Fire - Fire Sprinkler Hydraulics CalculatiàriPrórim , : ;'.•, .. Elite Software DeéIopnient, Inc. I Guardian Fire Protection l . CHASE BANK 00 LGiIbertAL85296. .•.. . ;.: .. '. .. . .. Pagj Fire Sp` rinkleiOUtpüt Data..: .. . OieraiINodeGroupiflgs.Oiitput.Data .. .. . . Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out (+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure (psi) Node (gpm) - 1 2 0 -17.75 17.75 0.00. 0.00 10.05 2 1 0 17.75 17.92 0.00 0.00 10.24 0.00134 2 3 0 -35.67 3 2 0 35.67 18.63 0.00 0.00 11.07 0.00200 3_ 4 0 -54.30 4 3 0 54.30 19.88 0.00 0.00 . 12.60 0.00322 4 18 0 -74.17 . 5 6 0 -14.86 14.86 0.00 0.00 7.04 0.00137 6 5 0 14.86 15.06 0.00 0.00 7.23 0.00041 6 7 0 -29.92 7 6 0 29.92 - 15.65 0.00 0.00 7.81 0.00105 7 8 0 -45.56 8 7 0 45.56 16.73 0.00 0.00 8.93 0.00171 -- .8 19 0 -62.30 9 19 0 -18.72 18.72 0.00 0.00 11.17 0.00313 10 11 0 -15.13 15.14 0.00 0.00 7.30 0.00052 11- 10 0 15.13 15.34 0.00 0.00 7.50 0.00065 11 12 0 -30.48 12 11 0 . 30.48 15.94 0.00 0.00 8.10 0.00102 12 13 0 -46.41 13 12 0 46.41 .17.04 0.00 0.00 9.26 0.00177 13 21 0 -63.45 14 21 0 -19.05 19.06 0.00 0.00 11.58 0.00328 15 16 0 -21.03 21.03 0.00 0.00 14.11 0.00263 16 15 0 21.03 21.23 - 0.00 0.00 14.37 0.00291 16 23 0 -42.26 17 23. 0 -22.02 22.02 0.00 0.00 15.47 0.00403 18 . 4 0 74.17 0.00 0.00 0.00 18.86 0.00000 18 20 0 -74.17 19 8 0 62.30 0.00 0.00 0.00 11.18 -0.00001 19 9 0 18.72 19 20 0 -81.01 20 18 0 74.17 0.00 .0.00 0.00 19.00 0.00000 20 19 0 81.01 .20220 -155.19 Fire- Sprinkler Hydraulics Calculation Program - -. .. Elite Software Inc. Inc. Guardian Fire Protection Azzo CHASE BANK tGiIbert, AL_85296 - ' ' Page 6J Fire Sprinkler Output Data 4 [..2yerall Nàde Groupings Output bata (cont'd) ' Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out (+) In (-) Residual Flow At Beg. Node 'Node Group (gpm) (gpm) (gpm) (gpm) Pressure (psi) Node (gpm) 21 14 0 19.05 21 22 0 -82.50 22 20 0 155.19 0.00 0.00 0.00 19.63 0.00000 22 21 0 82.50 --22 24 0 -237.69 23 16 0 42.26 0.00 0.00 0.00 15.47 0.00000 23 17 0 22.02 23 24 0 -64.28 24 22 0 237.69 0.00 0.00 0.00 21.02 0.00000 24 23 0 64.28 24 25 0 -301.97 25 24 0 301.97 0.00 0.00 0.00 30.92 0.00000 25 26 0 -301.97 26 25 0 301.97 0.00 100.00 0.00 46.79 -0.00012 26 27 0 -401.97 27 26 0 401.97 0.00 0.00 -401.97 53.91 F Fin- Fire Sprinkler Hydraulics Calculation Program Guardian Fire Protection LGilbert, AL 85296 . . -• 1 . Elite Software Dévelópment, Inc.] CHASE BANK Page 71 [Fire(Sprinkler Output Data - fOverall PipeOutpUt Data .. 1'., ... Beg. Nodal Elevation Spk/Hose End. KFactor Discharge Node (K) (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gprn) Velocity (fps) F. Lift Fittings Type-Grp PieL:n. Tot-Len (ft) PF-(psi) PE-(psi) PT-(psi) 1 5.60 18.00 17.75 10.05 1.25 17.75 0.02421 8.10 0.196 2 5.60 18.00 17.92 10.24 1.416 17.75 -----0.00 0.000 DYNA-THREAD NT 120 3.62 0 8.10 0.196 2 5.60 18.00 17.92 10.24 1.25 17.92 0.08809 9.40 0.828 3 5.60 18.00 18.63 11.07 1.416 35.67 -----0.00 0.000 DYNA-THREAD NT 120 7.27 0 9.40 0.828 3 5.60 18.00 18.63 11.07 1.25 18.63 0.19167 8.00 1.533 4 5.60 18.00 19.88 12.60 1.416 54.30 0.00 0.000 DYNA-THREAD NT 120 11.06 0 8.00 1.533 5 5.60 18.00 14.86 7.04 1.25 14.86 0.01743 11.10 0.193 6 5.60 18.00 15.06 7.23 1.416 14.86 0.00 0.000 DYNA-THREAD NT 120 3.03 0 11.10 0.193 6 5.60 18.00 15.06 7.23 1.25 15.06 0.06363 9.00 0.573 7 5.60 18.00 15.65. 7.81 1.416 29.92 0.00 0.000 DYNA-THREAD NT 120 6.10 0 9.00 0.573 7 5.60 18.00 15.65 7.81 1.25 15.65 0.13856 8.10 1.122 8 5.60 18.00 16.73 8.93 1.416 45.56 -----0.00 0.000 DYNA-THREAD NT 120 9.28 0 8.10 1.122 10 5.60 18.00 15.14 7.30 1.25 15.14 0.01803 11.10 0.200 11 5.60 18.00 15.34 7.50 1.416 15.13 -----0.00 0.000 DYNA-THREAD NT 120 3.08 0 11.10 0.200 11 5.60 18.00 15.34 7.50 1.25 15.34 0.06584 9.00 0.593 12 5.60 18.00 15.94 8.10 1.416 30.48 0.00 0.000 DYNA-THREAD NT . 120 6.21 0 9.00 0.593 12 5.60 18.00 15.94 8.10 1.25 - 15.94 0.14336 8.10 1.161 13 5.60 18.00 17.04 9.26 1.416 46.41 0.00 0.000 DYNA-THREAD NT . 120 9.46 0 8.10 1.161 15 5.60 18.00 21.03 14.11 1.25 21.03 0.03314 8.10 0.268 16 5.60 18.00 21.23 14.37 1.416 21.03 0.00 0.000 DYNA-THREAD NT 120 4.28 0 8.10 0.268 5.60 18.00 19.88 12.60 1.25 19.88 0.34136 4.60 4.960 18 0.00 15.00 0.00 18.86 1.416 74.17 ET 9.93 1.299 DYNA-THREAD NT 120 15.11 0 14.53 6.259 8 5.60 18.00 16.73 8.93 1.25 16.73 0.24715 9.10 2.249 19 0.00 18.00 0.00 11.18 1.416 62.30 0.00 0.000 DYNA-THREAD NT 120 12.69 0 9.10 2.249 9 5.60 18.00 18.72 11.17 1.25 18.72 . 0.02672 0.11 0.003 19 0.00 18.00 0.00 11.18 1.416 18.72 0.00 0.000 DYNA-THREAD NT 120 3.81 0 0.11 0.003 Fire Fire Sprinkler Hydraulics Calculation Program .. Elite Sàftware Development, Inc. 1 Guardian Fire Protection J CHASE BANK Gilbert, AL 85296 .. - Pagej iFire SprinkièrOütpUtMai - loverall Pipe Output bata Beg. Nodal Spk/Hose Residual Elevation Discharge KFactor Pressure (feet) Inside Dia Fittings It Len PE-(psi) Node (K) (gpm) (psi) C-Value Velocity (fps) Type-Grp (ft) PT-(psi) 18 0.00 15.00 0.00 18.86 2.50 0.00 0.01465 9.60 0.141 20 0.00 15.00 0.00 19.00 2.703 74.17 -----0.00 0.000 DYNA-FLOW-10 120 4.15 0 9.60 0.141 19 0.00 18.00 0.00 11.18 1.25 0.00 0.40184 3.00 6.526 20 0.00 15.00 0.00 19.00 1.416 81.01 2T 13.24 1.299 DYNA-THREAD NT -12016.50 0.16.247.825 13 5.60 18.00 17.04 9.26 1.25 17.04 0.25568 9.10 2.327 21 0.00 18.00 0.00 11.59 1.416 63.45 0.00 0.000 DYNA-THREAD NT 120 12.93 0 9.10 2.327 14 5.60 18.00 19.06 11.58 1.25 19.06 0.02762 0.11 0.003 21 0.00 18.00 0.00 11.59 1.416 19.05 0.00 0.000 DYNA-THREAD NT 120 3.88 0 0.11 0.003 20 0.00 15.00 0.00 19.00 2.50 0.00 . 0.05740 11.00 0.631 22 0.00 15.00 0.00 19.63 2.703 155.19 0.00 0.000 DYNA-FLOW-10 120 8.68 0 11.00 0.631 21 0.00 18.00 0.00 11.59 1.25 0.00 0.41563 3.00 6.750 22 0.00 15.00 0.00 19.63 1.416 82.50 2T 13.24 1.299 DYNA-THREAD NT 120 16.81 0 16.24 8.049 16 5.60 18.00 21.23 14.37 1.25 21.23 0.12054 9.10 1.097 23 0.00 18.00 0.00 15.47 1.416 42.26 0.00 0.000 DYNA-THREAD NT 120 8.61 0 9.10 1.097 17 5.60 18.00 22.02 15.47 1.25 22.02 0.03609 0.11 0.004 23 0.00 18.00 0.00 15.47 1.416 22.02 0.00 0.000 DYNA-THREAD NT 120 4.49 0 0.11 0.004 22 0.00 15.00 0.00 19.63 2.50 0.00 0.12633 11.00 1.390 24 0.00 15.00 0.00 21.02 2.703 237.69 -----0.00 - 0.000 DYNA-FLOW-10 120 13.29 0 11.00 1.390 23 0.00 18.00 0.00 15.47 1.25 0.00 0.26191 3.00 4.253 24 0.00 15.00 0.00 21.02 1.416 64.28 2T 13.24 1.299 DYNA-THREAD NT 120 13.10 0 16.24 5.552 24 0.00 15.00 0.00 21.02 2.50 0.00 0.19671 41.00 9.901 25 0.00 15.00 0.00 30.92 2.703 301.97 E 9.33 0.000 DYNA-FLOW-10 120 16.88 0 50.33 9.901 25 0.00 15.00 0.00 30.92 2.50 0.00 0.19671 15.00 9.375 26 0.00 0.00 100.00 46.79 2.703 301.97 BC 32.66 6.495 DYNA-FLOW-10 120 16.88 0 47.66 15.870 26 0.00 0.00 100.00 46.79 4.00 0.00 0.02395 276.00 7.113 27 0.00 0.00 0.00 53.91 4.266 401.97 5ETG 21.00 0.000 PVC C-900 PRESSURE CLASS 150 9.02 0 297.00 7.113 Fire FliSprinkler Hydraulics Calculation Pràgram. - •-. . .. Elite Software DeeIóieñtlriè Guardian Fire Protection CHASE BANK - Gilbert, AL 85296 .. .. .'.-' * ... .........••-.. Page9, Fire Sprinkler OutpUt Data 1 [Overall Sprinkler Output Data Flowing Sprinkler Residual Area Group Sprinkler Elevation Pressure Flowing Area Flowing Sprinkler (ft2) Density Discharge Sprinkler Code KFactor (K) Node No. (feet) (psi) (gpm/ft2) (gpm) 1 5.60 18.00 10.05 130.00 0.137 17.75 Sub Totals For Non-Group 130.00 0.137 17.75 2 5.60 18.00 10.24 130.00 0.138 17.92 Sub Totals For Non-Group 130.00 0.138 17.92 3 5.60 18.00 . 11.07 130.00 0.143 18.63 Sub Totals For Non-Group 130.00 0.143 18.63 4 5.60 18.00 12.60 130.00 0.153 19.88 Sub Totals For Non-Group 130.00 . 0.153 19.88 5 5.60 18.00 7.04 130.00 0.114 14.86 Sub Totals For Non-Group . 130.00 0.114 14.86 1 6 5.60 18.00 7.23 130.00 0.116 15.06 SubTotals For Non-Group - 130.00 0.116 15.06 7 5.60 18.00 7.81 130.00 0.120 15.65 Sub Totals For Non-Group 130.00 0.120 15.65 8 5.60 18.00 8.93 130.00 0.129 16.73 Sub Totals For Non-Group 130.00 0.129 16.73 9 5.60 18.00 11.17 130.00 .0.144 18.72 Sub Totals For Non-Group 130.00 . 0.144 . 18.72 10 5.60 18.00 7.30 130.00 0.116 15.14 Sub Totals For Non-Group . 130.00 0.116 15.14 11 5.60 18.00 7.50 130.00 0.118 15.34 Sub Totals For Non-Group 130.00 0.118 15.34 12 5.60 18.00 8.10 130.00 0.123 15.94 Sub Totals For Non-Group 130.00 0.123 15.94 13 5.60 18.00 9.26 130.00 0.131 17.04 Sub r Non-Group 130.00 0.131 17.04 14 5.60 18.00 11.58 130.00 0.147 19.06 Sub Totals For Non-Group 130.00 0.147 19.06 15 5.60 18.00 14.11 130.00 0.162 21.03 Sub Totals For Non-Group 130.00 0.162 21.03 16 5.60 18.00 14.37 130.00 0.163 21.23 Sub Totals For Non-Group 130.00 0.163 21.23 17 5.60 18.00 15.47 130.00 0.169 22.02 Sub Totals For Non-Group 130.00 0.169 22.02 Totals For All Groups 2210.00 0.137 302.00 Fir -Fire Srinkler Hydraulics Calculation Program Elite Software Development, incT Guardian Fire Protection' - , CHASE BANK Gilbert, AL 85296 ' Z3. Page 10 Fire Sprinkler Output Summary [iiiuiucauy Most Demanding Sprinkler Node HMD Sprinkler Node Number: 5 HMD Actual Residual Pressure: 7.04 psi HMD Actual GPM: 14.86 gpm [Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 1500.00 ft2 Minimum Desired Density: 0.100 gpm/ft2 Application Average Density: 0.201 gpm/ft2 Application Average Area Per Sprinkler: 88.24 ft2 Sprinkler Flow: 302.00 gpm Average Sprinkler Flow: 17.76 gpm I Flow Velocity And Imbalance Summary Maximum Flow Velocity (In Pipe 25 - 26) 16.88 ft/sec Maximum Velocity Pressure (In Pipe 25 -26) 1.92 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0065 psi Actual Average Nodal Pressure Imbalance: 0.0010 psi Actual Maximum Nodal Flow Imbalance: 0.0040 gpm Actual Average Nodal Flow Imbalance: 0.0012 gpm tOverall Network Summary Number Of Unique Pipe Sections: 26 Number Of Flowing Sprinklers: 17 Pipe System Water Volume: 241.78 gal Sprinkler Flow: 302.00 gpm Non-Sprinkler Flow: 100.00 gpm Minimum Required Residual Pressure At System Inflow 53.91 psi Node: Demand Flow At System Inflow Node: 401.97 gpm Fire Fire Sprinkler Hydraulics Calculation Program • : :, ElitiSoftware Develóment lnc.1 Guardian Fire Protection CHASE BANK Gilbert AL 85296: PagjjJ - 'L1ydrauIid:Suppli/Deiiiand •. 100 90 80 70 60 50 40 30 20 10 0 73 2 4 6 8 10 12 14 16 18 20 Flowrate(xl 00) gpm Supply Curve Data Static Pressure: 82.8 psi Test Residual Pressure: 72.8 psi Test Flow Rate: 1453 gpm Demand Curve Data Calculated Residual Pressure: 53.91 psi Calculated Flow Rate: 401.97 gpm Excess Available Residual Pressure At Calculated Flow: 27.96 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 7.79 psi April 25, 2008 Sprinkler 51a The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfase and MicrofastHP6 Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester and TeflonO coatings can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflone and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNlV nyu Approved: i...uass 20,20 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-H8407984B-PDA VdS Approved: Certificate G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved: Ref. No. 096e103, TE30401, and TE30872 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, and 0786-CPD-40171 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 51d and Design Criteria on page 51e for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http:llwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 06661B and 12281. Copper UNS-C19500 for Sprinklers 06665B, 06764B, and 07060. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 067196, 067176, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS-530400 For TeflonO Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated Form No. F_080488 Replaces page 51a-e, dated March 7, 2008. (Updated LPCB Approval on Sprinkler 14817.) Sprinkler 51 b April 25, 2008 MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Upright and Conventional sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/68° = A, 155°I68° = B. 175°/79° = D, 200°I93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" thread, Brass finish and a 155 ¶168 °C temperature rating = Part No. 06661 BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. April 25, 2008 Sprinkler 51c MICROFAST® AND MicrofastHP® QUICK N IKJNG4 RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinklir Temperature : Sprinkler Nominal.. Maximum Ambient Classification Temperature Rating1 Ceiling Temperature2 B lb C U o or Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® - Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. Protective Wrench Sprinkler Flat Cap Figure 1: Standard Sprinkler Wrench 10896W/B Sprinkler 51 d April 25, 2008 The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Chart --bmperature Tk Ey Microfast and MicrofastHP Quick Response I Upright and Conventional Sprinklers [1Xl- E.i::I;'.or.applicabIe) Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal I Overall Length Listings and Approvals' Number' SIN K-Factor ______________ (Refer also to Design Criteria on page 51e.) BSP U.S. I metric2 Inches I mm cULus4 I FM7 I NYC8 I VdS I LPCB I CE I 0 Upr ght-Standard Orifice 06661B I VK300 1 1/2' 1 15 mm 1 5.6 1 80.6 1 2-3/16 56 A2 I A3 A2 -- -- -- - 07060 1 VK345 I -- 15 mm 1 5.6 1 80.6 1 2-3/16 1 56 1 -- A3 I - A3 I A3 I B312 B3'4 Conventional -Standard Orifice 06766B I VK310 1 1/2" 115 mm I 5.6 I 80.6 1 2-3/16 L 56 I A3 I -- I A3 I -- I A3 I B312 I B31 Upright -Large Orifice ___________________ 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 A2 A3 A2 A3 A3 1B3'2 -- 14817 1 VK350 I -- 20 mm 1 8.0 1 115.2 1 2-5/16 1 59 1 A2 I A3 I A2 I A3 I A3 IB3'2 -- 06764B VK350 1 1/2" 1 15 mm 1 8.0 1 115.2 1 2-5/16 1 59 1 A2 I -- A2 I A3 I -- -- -- __________ Conventional-Large On ice 067686 I VK354 1 3/4" 1 20 mm 1 8.0 I 115.2 2-5/16 1 59 1 -A2 --1 -- I A3 I -- I A3 I B312 I -- __________ Upright-SmallOrifice 06714R"~j VK325 1 1/2" 1 15 mm 1 2.8 1 40.3 1 2-3/16 56 A2 I Al I A2 I -- -- . -- -- 06719B" I VK327 1 1/2" 1 15 mm 1 4.2 1 60.5 1 2-3/16 1 56 1 A2 I -- A2 I -- -- -- -- 06931 B" I VK327 I -- 10 mm 1 4.2 1 60.5 1 2-3/16 1 56 1 A3 I E113 -- Maximum 250 PSI (17 bar) WWP Upr ght-Standard Orifice Base Part Thread Size Nominal Overall Length Listings and Approvals3 k Number" SIN K-Factor _ (Refer also to Design Criteria on page 51e. NPT BSP U.S. metric2 Inches I mm I 7ULus4 I FM I NYC9 I VdS I LPCB I CE 1 0 12281 VK315 1 1/2" 1 15 mm 5.6 1 80.6 2-3/16 1 56 1 A2 I -- A2 I -- -- -- -- Upright-Srnaii Orifice10 12286" I VK340 I 1/2" 115 mm I 2.8 I 40.3 I 2-3/16 56 I A2 I - I A2 I -- Approved Temperature Ratings - A - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 -C).'200 OF (93 °C), - . Approved Finishes and 286 OF (141°C) 1 - Brass and Chrome-Enloy® B - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), and 286 OF (141°C) 2 - Brass, Chrome-Enloy®, White Polyester56, Black Polyester56, C - 135°F (57 °C), 155 OF (68 °C), 175 OF (79 °C), and 286 OF (141°C) and Black Teflon®5 D - 135 OF (57 °C), 155 OF (68 °C), and 175 OF (79 °C) 3 - Brass, Chrome-Enloy®, White Polyester56, and Black Polyester56 E- 155 OF (68 °C) I Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure. is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 9 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. '°Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. 12 (( Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40131. 14 ®. MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. April 25, 2008 Sprinkler 51e MICROFAST® AND MicrofastHP® QUICK '1 I FJ I1Gj RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart on page 51d cULus Listing Requirements: Microfast® and MicrofastHP5 Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. FM Aoeroval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_080488 Replaces page 51a-e, dated March 7, 2008. (Updated LPCB Approval on Sprinkler 14817.) March 14, 2008 Sprinkler 41 a MICROFAST® AND MicrofastHP® QUICK 'J I IJ r,1GI RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfase and MicrofastHP5 Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and TeflonO coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflone and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 IJfl A _ .___I %_I___I_. fli. ._L. -- -- .1 SlA #%S •SS - S rin.. Rppruveu; auenur riumoer and MEA o-i-t, votume lb ABS Certified: Certificate 04-H5407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-I, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http:!Iwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-Cl9500 for Sprinklers 066626, 06666B, 06765B, and 12104. Copper UNS-C 19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) Sprinkler 41 b March 14, 2008 MICROFAST® AND MicrofastHP® QUICK 4J C7G* RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-1\N, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/68° = A. 155°/68° = B, 175°/79' = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 066628AB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A 1/2 ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flats Protective Sprinkler Cap 10896 Figure 1: Standard Sprinkler Wrench 10896W/B - Sprinkler Wrench 12144W/Bww for installing coated and/or recessed pendent sprinklers with protective caps. **A 1/2' ratchet is required (not available from Viking). Carefully slide the wrench sideways around the protective cap, ensuring engage- ment with the sprinkler wrench flats. -c_.-------------- - Li ------Li March 14, 2008 Sprinkler 41c M[CROFkST® AND V4sJ I Fi(I MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature I SprinklerNominal Maximum Ambient Classification.. Temperature atingi Ceiling Temperattire2 B lb Col UOF Ordinary 135 'F (57 'C) 100 'F (38 'C) Orange Ordinary 155 'F (68 'C) 100 'F (38 'C) Red Intermediate 175 'F (79 'C) 150 'F (65 °C) Yellow Intermediate 200 'F (93 'C) 150 'F (65 'C) Green High 286 °F (141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler 41d March 14, 2008 MICROFAST®AND "J I F1G MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Approval Chart Temperature KEY Finio Microfast' and MicrofastHP Quick Response Pendent Sprinklers Maximum 175 PSI (12 bat) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No." NPT BSP U.S. metric2 Inches mm rULus4J FM5 NYC° VdS LPCB I (E I Standard Orifice 06662B VK302 1/2 115 mm 5.6 80.6 2-1/4' 58 1 AiX, B1Y I A3X, 133Y AiX, B1Y A3 A3X, 133Y C3X, E3Y13 C3X, E3Y15 Large Orifice 06666B VK352 3/4' 20 mm 80 115.2 2-3/8" 60 A1X,BiY A2x, 132Y AIX, B1Y -- A3X C3' -- 12104 VK352 3/4" 20 mm 80 115.2 2-1/4" 58 -- -- -- 03 -- -- -- 06765B VK352 1/2" 15 mm 80 115.2 2-3/8" 60 AiX, B1Y - AiX, B1Y A3 -- -- -- Small Orifice9 067181310 VK329 1/2" 15 mm 28 40.3 2-3/16" 56 AiX, B1Y A2X AiX, B1Y -- -- -- -- 06720B'° VK331 1/2" 15 mm 42 60.5 2-1/4" 58 AiX, B1Y -- AiX, B1Y -- -- - -- 069328 VK331 -- 10 mm 4.2 60.5 2-3/8" 60 -- -- -- A3 -- G2' -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN - K-Factor Length (Refer also to Design Criteria onpage 41e.) Part No' NPT BSP U.S. metric2 Inches mm cULus4 FM NYC" VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, BIY - AiX - -- -- -- Maximum 250 PSI (17 bar) WWP Small 6rifice9 1229010 1 VK342 1/2" 115 mm 1 2.8 F40.3 2-3/16" 56 1 AIX, BIY I Aix -- Approved Temperature Ratings Approved Escutcheons A- 135 OF (57 "C), 155 OF (68 "C), 175 OF (79 "C) 200 OF (93 "C), Approved Finishes X - Standard surface-mounted escutcheon or and 286 OF B - 135 OF (57"d) 155 (68 °C) 175 "F (79 "C) and 200 "F (93 °C) 1 - Brass, Chrome-Enloy®, White Poly- the Viking Microfast® Model F-i Adjustable C - 155 OF (68 °C), 175 OF (79 "C), 200 OF (93 °C), and 286 OF ester78, Black Polyester78, and Black Escutcheon 12 (141 "C) Teflon®7 V - Standard surface-mounted escutcheon or D - 135 OF (57 "C), 155 OF (68 "C), 175 OF (79 "C), and 286 OF 2 . Brass and Chrome-Enloy® the Viking Microfast® Model F-i Adjustable (141 "C) 3- Brass, Chrome-Enloy®, White PoIyester8, Escutcheon12 or recessed with the Viking ,, F (79 :'F (141 and Black Polyester8 Micromatic® Model E-1 or E-2 Recessed G - 155 OF (68 "C) I Escutcheon Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. ° Other colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. '°The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 12The Viking Microfast° Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sj,rinkler to be recessed behind the face of the wall or ceiling. 13 (K Certified, Standard EN 12259-1, EC 0832-CPD-2001 0832-CPD-2003. -certificate of conformity and 14 C.E Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-401 30 and 0786-CPD-401 70. '5 G MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008. March 14, 2008 Sprinkler 41e MICROFAST® AND MicrofastHP® QUICK II(II1GI l:ll[u.7M.. RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer. to the Approval Charton page 41d) cULus Listing Requirements: Microfast! and MicrofastHP5 Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small onfice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM AnrovaI Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (58,7 mm) minimum 2-1/2' (63.5 mm) maximum 2-1/8' (54 mm) 1/2' NPT (15 mm) _ I 1-5/8' W (58 mm) (41 mm) Pendent Sprinkler 06662B (VK302) 1-3/4' (44.5 mm) InstoJ.Lecl with a standard 1/8' surface- mounted escutcheon. t -J 11 2' 1-1/2" (38,1 mm) (50.8 mm) Minimum Maximum Installed with a Microf'ast Model F-i AdjustabLe Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Sprinkler 41f March 14, 2008 MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com I 2-1/8" I Ceiling Opening Size: I 2-1/8" I I a- Ia -i (54 ) 2-5/16' (58,7 mm) minimum I (54 mm) I 2-1/2" (63.5 mm) maximum 1-3/4" \ 1-1/8" (28.6 mm) (44.5 mm) Minimum Maximum Lj f Installed with a Microma-tic Model E-1 Recessed Escutcheon \I JI )II1_1'8" (28.6 mm) (50.8 mm) çJ Minimum Maximum Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F 081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) NPS Nominal I.D. Wt. wt. (H20 Filled) CRR In; mm In; mm lbs/Ft; kg/rn Lbs/Ft; kg/rn Unthreaded 1.191 0.830 1.31 2.41 25 30.3 1.2 1.95 - 1'/4 1.536 1.059 1.87 1.55 32 39.0 1.6 2.78 - '1½" 1.728 1.667 2.71 3.44 40 43.9 2.5 4.03 - 2.2031 2.104 3.79 2.78 50 56.0 3.1 5.64 - 2½" 2.703, 2.564 5.10 1.60 65 68.7 3.8 7.59 - 3.314 3.387 7.18 1.48 75 84.2: 5.0 10.69 - 4.310 4.473 10.86 1.00 100 109.5 ' ' 6.7 16.16 - 11~9 C 0 "~~ APPROVED cDDcO@ w High Strength Steel Pipe Exceptional hydraulics Lightweight and easy to install Available factory roll grooved UL and cULlisted FM approved ® The original high-strength light wall sprinkler pipe with superior hydraulics. Dyna-Flow is the "original" high-strength light wall sprinkler pipe. With outstanding hydraulic capabilities, Dyna-Flow is recognized as the most popular alternative to Schedule- 10 pipe. Lightweight and easy to cut, Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter (ID) up to 11% larger than Schedule-40 and up to 7% larger than Schedule -10, Dyna-Flow pipe hydraulics are exceptional. Larger ID's enable Dyna-Flow and related components to be down-sized within the system, increasing the potential for job cost savings. For complete Hazen Williams charts, refer to "Dyna-Flow Hydraulic Data Tables". Dyna-Flow pipe has metallurgical properties that provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There are no special processes or equipment needed for fabrication and installation. ® Superior Coating Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. ® American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Flow pipe is manufactured to meet ASIM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna-Flow are UL and cUL listed and FM approved. Dyna-Flow is UL and cUl listed for use with roll grooved, plain-end and welded joints for wet, dry, pre-action and deluge systems. It is FM approved for roll grooved, plain end and welded joints for wet systems. Dyna-Flow is available "hot-dip" galvanized** and has been specifically approved by FM for dry system uses. Dyna-Flow complies with NFPA 13 and is rated at 300 psi working pressure. ** must be ordered in 10 bundle increments II Customer Service (800) 882-5543 Fax: (800)659-7730 www.alliedtube-sprinkler.com CIe 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. 600 Dean Sievers Place TUBE & CONDUIT' Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 CRR CRR 11.39 1.00 9.50 1.00 9.14 1.00 8.41 1.00 Widely accepted substitute for Schedule 40 NPS Nominal I.D. Wt. Wt. (H20 Filled) Standard hanger spacing mm -. In, mm Lbs/Ft; kglm Lbs/Ftjq. 1.330 1.75 UL and cUL listed 25 27.4. .0 2:O. 1¼" 1.408 1.870 2.54 FM approved 32 . 35.8 .•. - 28. 3 lW 1.639 290 3.22 3.4 2" 2.104 3.050 4.57 ® Combining the safety and longevity of Sch-40 with quality and hydraulic advantages. Dyna-Thread" pipe is the full line Schedule 40 replacement with the same CRR of Schedule 40, 1.00, providing Dyna-Thread with the same life expectancy as Sch-40. With outstanding hydraulic capabilities, Dyna-Thread is a more widely accepted product substitution than lightwall threadable pipe when Sch-40 is specified. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 and provides improved hydraulics. When used in combination with Dyna-Flow pipe, down sizing of pipe and related components often occurs, thereby reducing costs. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. Increased strength and lighter weight allows Dyna-Thread to reduce installation fatigue and makes it ideal for retro-fit applications. ® Superior Coating Dyna-Thread products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. ® American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Dyna-Thread pipe is manufactured to meet ASIM A-135, Type E Grade A, is in compliance with NFPA-13 and all sizes are rated at 300 psi working pressure. Dyna- 10 CIO <~~> APPROVO Thread is UL and cUL listed for wet, dry deluge and pre-action sprinkler systems and FM approved for use in wet systems. Dyna-Thread can be hot dip galvanized** to meet FM requirements for use in dry systems. Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved and plain end fittings. - ** must be ordered in 10 bundle increments PO 0 Customer Service (800) 882-5543 Fax (800) 659 7730 www alliedtubi 16100 S lathrop Ave 11350 Norcom Rd • 2525 N 27th Ave 600 Dean TUBE & CONDUIT Harvey 1160426 Philadelphia PA 191S'i Phoenix AZ 8500° MorrisvillE Description The 6" and 10" Alarm Bells provide an audible notification of a sprinkler system event. Can be used to signal flow with in the sprinkler system or tampering with a monitored valves. Each bell is complete and provides 4 wire connectivity for "through" wiring to additional devices*. UL Listed. Specifications Size: 6", 10" Power: 120VAC (4 conductor) Finish: Red Installation Install according to the installa- tion instructions provided with each bell. Installation of the alarm bell should be performed by a qualified electrician only. Improper installation may cause electrical shock, damage or failure of one or more connected devices. MAKE SURE SOURCE POWER HAS BEEN DISCON- NECTED AND "LOCKED OUT" PRIOR TO INSTALLA- TION AND CONNECTION OF THE ALARM BELL TO ANY DEVICE. Additional Accessories: ABS Back Box Wire Bell Cage 02009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc 13. F!.,, -1. 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 t ,, I For questions: 1 800 344-1822• 1 800 344-3775 fax • www.fppi.com SYSTEM SENSOR WFD Series Waterfiow Detector System Sensor's WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2 "through 8 and can be mounted in a vertical or horizontal position. Features Robust Construction. The WFD series consists of a rugged, NEMA 4 rated enclosure. Desi;ned for both indoor and outdoor Two-inch conduit openings in new WFD30-2 models use, the WFD series operates across a wide temperature range, from UL listed models are NEMA 4 rated 320F to 120 F. Sealed retard mechanism immune to dust and other contaminants Visual switch activation Field replaceable retard mechanism and SPDT switches Rugged, dual SPDT switches enclosed in a durable terminal block Accommodates up to 12 AWG wire Designed for both indoor/outdoor use 100 percent synchronization activates both alarm panel and local bell Tamper resistant cover screws Agency Listings @ @ A MEA <~> LISTED approved C5169 AMRDKD 5739 77704209.140 167.93.0 1W9f,2M Reliable Performance. UL lsted models are equipped with tamper resistant cove, screws to prevent unauthorized entry. Inside, two sets of SPDT (Fcrm C) synchronized switches are enclosed in a durable terminal bloc< to assure reliable performance. False Alarm Immunity. The WFD series incorporates a mechanical retard feature, which minimizes the risk of false alarm due to pressure surges or air t -apped in the sprinkler system. In addition, the mechanical retard's unique sealed design is immune to dust and other contaminants. Simplified Operation. The WFD series is designed to simplify installation. Two conduit oper.ings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field-replaceable. Delay Adjustment Dial Overall Dimensions, Installed 'p°. NOTE: Retard Gets n,°y exceed 90 sectruls. Adjust and we* thol 1m0 dm not ,,c,ed 90Ic,tds. Pt" Pinhic vane Waterfiow Detector Vane-type waterfiow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least & from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24 from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi' for 2'- & pipes. The detector shall respond to waterfiow in the specified direction after a preset time delay which is field adjustable.The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. IFi7IHTiUi.iii J, --77 4 - Static Pressure Rating 450 PSI' Operating Temperature Range 32°F to 120°F (0°C to 49°C) Maximum Surge 18 Feet Per Second (FPS) Enclosure Rating' NEMA4 - suitable for indoor/outdoor use Triggering Threshold 4-10 GPM Cover Tamper Switch Standard with ULC models, optional for UL Bandwidth (Flow Rate) models, part no. 546-7000 Conduit Entrances Two openings for Wconduit. Service Use Automatic Sprinkler: NFPA-13 One open, one knock-out type One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Contact Ratings Two sets of SPDT (Form C) U.S. Patent Numbers 3,845,259 10.0A,1/2 HP@ 125/250 VAC 4,782,333 2.5A@6/12/24V0C - 5,213,205 Compatible Pipe Steel water pipe, schedule 10 through 40 Warranty 3 Years WFDE Field Wiring Diagram '' i?°" CaNTATRA11NsB atod4L&.l,on,,,w, lay.c l0ps — 24V0C I 25McPS WD see TVWAFM bar Were UL Model ULC Model Pipe Size Hole Size Shipping Weight WFD20 WFD20A 2 1 V4 4.2 lbs. WFD25 WFD25A '21h- 1W 4.3 lbs. WFD30-2 WFD30-2A 3 2 4.5 lbs. WFD35 WFD35A 31/2- 1Y4 4.7 lbs. WFD40 WFD40A 4 2 5.2 lbs. WFDSO WFD50A 5 2 6.3 lbs. WFD60' WFD60A 2 6.8 lbs. WFD80' WFD80A 2 7.5 lbs. Accessories A3008-00 Retard mechanism A77-01-02 Terminal block 546-7000 Tamper proof switch kit WFDW Tamper proof wrench for cover WFDN4 Gasket kit 'Maximum pressure rating 400 psi as approved by Factory Mutual. SYSTEM 3825 Ohio Avenue. St. Charles, IL 60174 ' Z-4 SEIISOR! Phone: 800-SENSOR2. Fax: 630-377-6495 Pradw tochange4t t,ne,ce,hot etenz,.kn AOS.019O-Ol1.3107.9676 INSTALLATION AND MAINTENANCE INSTRUCTIONS WFD Vane-type Waterfiow Detectors SYSTEM $ SENSOR 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systernsensor.com Specifications Contact Ratings: Triggering Threshold Bandwidth (Flow Rate): Static Pressure Rating: Dimensions, Installed: Operating Temperature Range: Compatible Pipe: Shipping Weight: Enclosure Rating: U. S. Patent Numbers: 10 A @ 125/250 VAC '; 2.5 A @ 24 VDC 4 to 10 gpm See models listed below. 3.5"H x 3.0"W x 6.7"D 32°F to 120°F (0°C to 49°C) Steel water pipe, schedule 10 through 40. 4 to 7 lb., according to size: NEMA Type 4, as tested by Underwriters Laboratories, Inc. (IP56) 3,845,259; 4,782,333; 5,213,205 Important Please Read Carefully And Save This instruction manual contains important information about the installation and operation of waterfiow detectors. Purchasers who install waterfiow detectors for use by oth- ers must leave this manual or a copy of it with the user. Read all instructions carefully before beginning. Follow only those instructions that apply to the model you are installing. ACAUTION I Use vane-type waterfiow detectors in wet-pipe systems only. Do NOT use them in dry pipe, deluge, or preaction systems. The sudden inrush of water in such systems may break the vane or damage the mechanism. Do not use in potentially explosive atmospheres. Do not allow unused wires to remain exposed. *Maximum Pressure Rating 400 psi8 as approved by Factory Mutual Research. I AcAulloNi Do NOT use any of the WFD models on copper pipe. The clamping forces of the mounting bolts may collapse the pipe sufficiently to prevent the detector from functioning properly. Do NOT install steel or iron pipe sections in copper piping for mounting a waterfiow detector. Incompatibility between the dissimilar metals causes bimetallic corrosion. NFPA 25: Inspection,Testing and Maintenance ;f Sprinkler Systems, Section 5.3.3.2 Other applicable NFPA standards, local codes, and the requirements of the authority having jurisdiction NOTE: Installation methods other than those listed in this installation manual may prevent the device from reporting the flow of water in the event the associated sprinkler sys- tem is activated by a fire. System Sensor is not responsible for devices that have been improperly installed, tested, or maintained. Mount the detector where there is adequate clearance for installation and removal and a clear view of it for inspections. See Figure 1 for mounting dimensions. Locate the detector 6 to 7 ft. above the floor to protect from accidental damage. On horizontal runs, position the detector on the top or side of the pipe. Do not mount it upside down because condensation may collect in the housing and impair the operation of the detector. For vertical flow applications, mount the detector on pipe through which water flows upward. Otherwise, the unit may not operate properly. Mount the detector at least 6 inches from a fitting that changes the direction of water flow and no less than 24 inches from a valve or drain. I56-0459-016R Installation Guidelines Before installing any waterfiow alarm device, be thorough- ly familiar with: NFPA 72: National Fire Alarm Code NFPA 13: Installation of cnrinitlpr Sustems o,-tinn 1 1 7 Principles Of Operation Vane-type waterfiow detectors mount to water-filled pipes in sprinkler systems. Waterfiow in the pipe deflects a vane, which produces a switched output-usually after a speci- fied delay. All waterfiow detectors have a pneumatically controlled mechanical delay mechanism. Delays do NOT accumulate; they reset if the flow of water stops before the entire delay has elapsed. All switches actuate when the water flow rate is 10 gallons per minute or greater, but will not actuate if the flow rate is less than 4 gallons per minute. This System Sensor installation manual covers the following waterflow detectors for sprinkler/fire alarm applications. Pipe Max. Pressure Model Pipe Size Schedule Rating (psig) WFD20 2" 10 thru 40 450 WFD25 21/2" 10 thru 40 450 WFD30-2 3" 10 thru 40 450 WFD35 31/2" 10 thru 40 450 WFD40 4" 10 thru 40 450 WFDSO 5" 10 thru 40 450 WFDGO 6" 10 thru 40 450* WFD80 8" 10 thru 40 450* D770-01-00 5. Be sure the direction-of-flow arrow matches the direc- Figure 1.. Mounting dimensions; tion of now in the pipe. Mounting Instructions Drain the pipe. Cut a hole at the desired location. Center the hole in the pipe, as shown in Figure 2, and be sure the hole is perpendicular to the center of the pipe. Before drilling, use a punch or scribe to mark the drill site to prevent the bit from slipping. If the hole is off center, the vane will bind against the inside wall of the pipe. Use a drill or hole saw to cut a hole of the proper diameter. See Table 1 for hole size. I AcAulloNi When drilling the hole with a hole saw, make certain that the center of the cut does not remain in the pipe. Remove burrs and sharp edges from the hole. Clean and remove all scale and foreign matter from the inside of the pipe for one diameter on each side of the hole to ensure free movement of the vane. Clean the outside of the pipe to remove dirt, metal chips, and cutting lubricant. Seat the gasket against the saddle and mount the detector directly to the pipe. Carefully roll the vane opposite the direction of flow and insert it through the hole. Seat the saddle firmly against the pipe so that the locating boss goes into the hole. Install the U-bolt, tightening the nuts alternately to ensure a uniform seal. See Table 2 for torque values. Remove the metal cover with the tamper-proof wrench provided. Move the actuator lever back and forth to check for binding. If the vane binds, remove the detec- tor and correct the cause before proceeding. I AcAurloNi Be sure the direction-of-flow arrow points in the right direc- tion or else water flow will go unreported. See Figure 3. Pre-Operation Testing Fill the sprinkler system and check for leaks around the waterfiow detector. If it leaks, first check for the proper torque on the U-bolt nuts. If the leak persists, drain the system and remove the detector (refer to Maintenance). Check for dirt or foreign objects under the gasket, and make sure that the pipe surface is not dented. Reinstall the detector and check again for leaks. Do not proceed until all leaks have been stopped. Connect an ohmmeter or continuity tester across the COM and B switch terminals. The ohmmeter should indicate an open circuit. Deflect the actuator lever and hold it until the pneumatic delay shaft releases the switch buttons. The ohmmeter or continuity tester should show a short circuit after the delay has elapsed. If there is no delay, check the setting of the delay adjustment dial. 'ipe tic vane Overall width pipe diameter + 7.6 cm (3) Figure 2. Mounting hole location: Wrong T - I - i L -~ IT Right - Remove burrs from edge of hole. Clean Out scale and foreign matter from inside wall of pipe. W01116.011 Table 1: WFD MODEV HOLE SIZE 20, 25, 35 30-2, 40, 50, 60, 80 2" Table 2: WFD MODEL* TORQUE 20. 25, 35 30-35 ft.-lb. 30-2, 40, 50, 60, 80 55-60 ft-lb. Wiring FA-WARNING] High Voltage. Electrocution Hazard. Do not handle live AC wiring or work on a device to which AC power is applied. Doing so may result in injury or death. When utilizing switches at voltages greater than 74VDC or 49VAC r.i means to provide all—pole disconnec- tion must be incorporated in the fixed wiring, such as a circuit breaker. U-bolt flu Pipe saddle U-bolt W0105-OO D770-01 -00 2 156-0459-016R Figure 3. Assembly diagram: Tamper proof wrench Z er Terminal block ! (Replacement P/N A77-01.02) Delay mechanism (Replacement Electrical conduit entrance /N A3008-00) (22.2 mm dia.) Mounting plate U bolt nut Pipe saddle Plastic vane 'N Roll paddle opposite I I of flow arrow while inserting Pipe Saddle gasket 7U Refer to Table 2 U bolt Figure 4. WFD wiring: NOTE: Common and B connections will close when vane Is deflected. I.,.. when water is flowing. Dual switches permit applications to be combined on a single detector. CONTACT RATINGS t2SI2SOVAC IeAMPc 24 VDC 1 2.5 AMPS Fire Alarm Control Panel lljplcol Fire Alone Control Panel Connection Two Waterfiow Detectors Shown power worse omPwith,atibtn I--9 i' __• bell Break wire on shown for Iconnection. schematic o, DO NOT allow stripped wire Typical Local Belt Connection IndIaidCel conch W023400 in n, W,t.rltow' feeds to extend beyond witch housing. DO NOT Condition leep mireo. All models have two SPDT switches. Switch contacts COM and B are closed when water is flowing and open when it is not. Connect the switches, as shown in Figure 4, depending on the application. When connected to a listed sprinkler/fire alarm control panel, the initiating circuit must be nonsilenceable. A ground screw is provided with all waterflow detectors. When grounding is required, clamp wire with screw in hole located between conduit entrance holes. See Figure 5A, page 4. If a second conduit entry is required, remove the knockout plug using a flat blade screwdriver as shown on Figure 513, page 4. Strike sharply with a hammer to pierce the wall of the knockout plug. Move to an adjacent wall section and repeat until the plug falls out. Make sure that the waterflow detector is supported adequately during this operation to avoid injury. Mechanical Delay Adjustment The pneumatic delay is preset at the factory to 30 seconds. To adjust the setting, turn the adjustment dial clockwise to increase the delay, counterclockwise to decrease it. The delay is adjustable from 0 to 70 seconds. See Figure 6, page 4. NOTE: Set the delay to the minimum required to prevent false alarms from flow surges. Periodically test time delay as required by Authority Having Jurisdiction or code authority. Maintenance To prevent accidental water damage, control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. Inspect detectors in accordance with applicable NFPA codes and standards and/or the authority having jurisdic- tion for leaks and replace if a leak occurs. Test detectors at least quarterly, as described under Operational Testing, to ensure proper operation. Test more often if required by the authority having jurisdiction. Under normal conditions, System Sensor waterflow detec- tors should provide years of trouble-free service. However, if the delay mechanism or switch enclosure needs to be replaced, follow these directions. To replace the delay mechanism or switch enclosure, use a /I6" socket head Operational Testing Always notify a central station monitoring waterflow alarms before repairing, maintaining, or testing waterflow alarm devices. waioi.Oi 1. Replace the cover and tighten the tamper proof screws with the tamper proof wrench. Store the wrench in a secure place. 2. Open the inspector's test valve and time how long it takes for the detector to indicate a flow condition. The detector should remain activated until the inspector's test valve is closed. Air pockets in the sprinkler system may increase the apparent delay. D770-01 -00 3 156-0459-016R screwdriver to remove the three screws that hold it in place. Either mechanism can be easily replaced without removing the detector from the pipe or draining the pipe. To replace the delay mechanism, request Part No. A3008-00. For switch enclosure, request Part No. A77-01-02. Do not repair or replace any other waterflow detector components. If any other part of the detector does not perform properly, replace the entire detector. Installation methods other than those listed in this installation manual may prevent the device from reporting the flow of water in the event the associated sprinkler system is activated by a fire. System Sensor is not responsible for devices that have been improperly installed, tested, or maintained. To remove a detector: Drain the pipe. Turn off electrical power to the detector and disconnect the wiring. Loosen the nuts and remove the U-bolts. Gently lift the saddle far enough to get your fingers under it. Then, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. Lift the detector clear of the pipe. I ACAUTION I If a vane breaks in a pipe, find and remove it. If it is not removed, the vane may restrict the flow of water to all or part of the sprinkler system. Figure SA. Ground screw location: GROUND F SCREW / (GREEN) MOUN - 1rPLATE Ll— I T7M W0103-OO Figure 511. Knockout nlu removal: WOtt80I Delay adjustment dial: NOTE: Retard time may exceed 90 seconds. WOlt 2-01 Adjust and verify that time does not exceed 90 seconds. Delay adjustment dial Please refer to insert for the Limitations of Fire Alarm Systems I àWARNING I The Limitations of Waterfiow Alarm Devices Waterfluw detectors may not work or operate properly if sprinkler piping being 3. Vane-type waterfiow detectors have a normal service life of tO-IS years. Hard monitored is plugged with pipe scale, mud, stones or other foreign material, water systems, however, may substantially reduce waterflow detector service life. Sprinkler systems should be checked regularly for such blocking material. fol- 4. Waterflow detectors are not a substitute for insurance. Building owners should lowing the instructions in Chapter of NFPA Standard 13A. always insure properly and lives being protected by sprinkler systems. Alarms generated by the activation of waterflow detectors may not be received 5. If valves controlling the water supply to a sprinkler system are closed, vane-type by a central station if telephone or other communication lines to the detector are waterflow detectors will not work. All valves controlling a sprinkler water supply out of service, disabled, or open, should be seated or locked in the normally open position. The normally open position should be monitored by a sprinkler supervisory switch. Three-Year Limited Warranty System Sensor warrants its enclosed waterflow detector to be free from defects in Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunc. materials and workmanship under normal use and service for a period of three lion and suspected cause of failure. The Company shall not be obligated to repair or years from date of manufacture. System Sensor makes no other express warranty replace units which are found to be defective because of damage, unreasonable use, for this waterflow detector. No agent, representative, dealer, or employee of the modifications, or alterations occurring alter the date of manufacture. In no case shalt Company has the authority to increase or alter the obligations or limitations of this the Company be liable for any consequential or incidental damages for breach of this Warranty. The Company's obligation of this Warranty shall be limited to the repair or or any other Warranty, expressed or implied whatsoever, even if the loss or damage replacement of any part of the waterflow detector which is found to be defective in is caused by the Company's negligence or fault. Some states do not allow the exclu- materials or workmanship under normal use and service during the three year period sion or limitation of incidental or consequential damages, so the above limitation or commencing with the date of manufacture. After phoning System Sensor's toll free exclusion may not apply to you. This Warranty gives you specific legal rights, and you number 800-SENSOR2 (736.7672) for a Return Authorization number, send defective may also have other rights which vary from state to state. Units postage prepaid to: System Sensor, Returns Department, RA IS , 3825 D770-01-00 4 156-0459-016R 02005 System Sensor Carlsbad Municipal Water District Potable Water Discharge Event Report Date: 62244TL__ 3440IVIATMERCAT0T Location: CARLSBAD, CA 92009 7/ Reason for Discharge Event: FIRE SPRINKLER HYDRANT DISCHARD DATA Type of Event: inivai Dewatering Water Mains ( Jlr Estimated Discharge Flow: 4359 &?M Note: Includes flow testing and flushing Dewatering Reservoirs Start Time 800 AM - UnschoduledWater Discharge End Time 8:03 AM Pre-Dechlorination Residual: 82 Ciear flow path of debris, surface contaminants and/or hazardous Post-Dechlorination Residual: 82 materials. Do not remove native (less than 0.1 mg!L) vegetation. pH within limits of 6.0 and 9.0 _______ Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity ot discharge water. iLA- Upon comletiorióf dewatering, ensure that the flow path is tree of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediment oi silted areas are cleared. Water Sampling Performed by: - Comments: Submitted by: Reviewd by: (Name a Date) (Name a Date) Flow Test Record Test Hydrant 3440 VIA MERCATO Location CARLSBAD, CA 92009 Hydrant ID No. Size main 8" PVC DR-1 8 Static ............. 92 Residual.........82 Pressure Drop 10 (PD! 1).....K factor for PD! 1 347 Flow: Hydrant(s) Hydrant I location Hydrant 2 location Hydrant 3 location Hydrant I Pitot 75 PSI GPM:1453 Size.of Orifice 2.5 Hydrant 2 Pitot PSI GPM: Size of Orifice_________ Hydrant 3 Pitot PSI GPM: Size of Orifice__________ Total:— 1453 (Qi) CalcUlated test and flow, data - 0 x PD2 k =:.Q2 PDI*k Static: ..................... 92 Desired Residual.......20 Pressure Drop (PD 2)72 K factor PD 2:10.07 1453 x 10.07 divided by 3.47 equals4216 GPM at 20 psi residual Qi PD2k PD1k Q2 Comments: Test conducted for: CHASE BANK - LA COSTA & RANCHO SANTA FE STORE #17194 Conducted by:CHRIS GRIFFIN - GUARDIAN FIRE PROTECTION Date:6-22-14 Time:8:00 AM