HomeMy WebLinkAbout3440 VIA MERCATO; ; FA140128; Permit5/2/24, 3:54 PM FA140128 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA140128 Job Address: 3440 VIA MERCATO Status: ISSUED Permit Type: FALARM Applied 8/28/2014 Parcel No: 2230507200 Approved: 9/8/2014 Lot #: 0 Reference No.: Issued: 9/8/2014 PC #: Inspector: Project Title: CHASE BANK -FIRE ALARM CONTROL PANEL W/ A BUlLDTIN DIALER FOR REMOTE MONITORING (24 HR ATTENDED LOCATION) -SMOKE DETECTOR ABOVE THE FIRE ALARM CONTROL PANEL - REMOTE ANNUNCIATION AT THE MAIN ENTRY -HORN/STROBE AT THE MAIN ENTRY -SPRINKLER SYSTEM MONITORING OF THE WATER FLOW SWITCH, BUTTERFLY TAMPER SWITCH AND PIV TAMPER. -DUCT SMOKE DETECTION MONITORING (DUCT DETECTORS AND SHUTDOWN BY OTHERS) -DUCT SMOKE DETECTORS SHALL BE FURNISHED AND INSTALLED BY OTHERS. -THE ADDRESSABLE DEVICES WILL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL INTELLIGENT LOOP. ALL DEVICES WILL HAVE A TEXTUAL DISPLAY ON THE FIRE CONTROL PANEL DESCRIBING TYPE OF DEVICE AND LOCATION. Applicant: KOR FIRE & SECURITY 26812 VISTA TERRACE LAKE FOREST, CA 92630 949-273-8340 Owner: PROPERTY DEVELOPMENT CENTERS L L C C/O SAFEWAY INC 5918 STONERIDGE MALL RD PLEASANTON CA about:blank 1/2 5/2/24, 3:54 PM FA140128 Permit Data Fees ($) Add'l Fees ($) Total ($) Balance ($) 286 0 286 0 about:blank 2/2 DF-52418:C • A1-20 MS"9050UD(E) Flre•uTe°ALarms Fire Alarm Control Panel (a with DACT by Honeywell AressaIl it±LJitt1 The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050U0 programs just like Fire•Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload! Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with WindowsTM 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire•Lite Upload/Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmitter. (4XTMF) New options include a UL listed printer, PRN-6F and the new IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- cation over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9050U0 is used in this data sheet to refer to both the MS-9050UD and the MS- 905OUDE FAGPs. For MS-905OUDC, refer to DF-60445. Features Listed to UL Standard 864, 9th edition. Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style V (Class B) NAC circuits. Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. EIA-232 PC interface. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. Point trouble identification. Waterfiow selection per module point. Alarm verification selection per detector point. Maintenance alert warns when smoke detector dust accumu- lation is excessive. One-person audible or silent walk test with walk-test log and printout. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant). Up to eight ANN-BUS annunciators. Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator. Upload/Download (local or remote) of program and data via integral DACT. SLC COMMUNICATION LOOP Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. 50 addressable device capacity (any combination of address- able detectors and modules). Compatible with FireLite's addressable devices (refer to SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style V (Class B) - Style Z (Class A) - Door Holder Service (cannot be used for notification appliances) - Aux Power Source (cannot be used for notification appliances) Silence Inhibit and Autosilence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 A total power for NACs. NOTE: Maximum or total 24VDC system power shared between all NAG circuits and the ANN-BUS is 2.7 A. FA140128 DF-52418:C • 12116/2009 - Page 1 of 4 FLP rflp'? 355 I Graphic LED Module Adapt Detector ANN-LID cc7-I #c H3551H355R1H355HT Relay Module Heat Detector ANN-RLY P211 Strobe Dual Monitor Module StrobePower Supply Photo/Thermal I P2R Strobe ___J Multi-Modules MMF-300 • CRF-300-6 Six-Relay Control Module Monitor Module • CMF-300-6 Six-Circuit Supervised control Module J ________ • MMF-302-6 Six-Zone Interface Module MMF-300-10 Ten-Input Monitor Module MMF-302 2-Wire Detector Monitor Module D5PL Beam Detector IDuct Detector BEAM-335/(S) MS-9050UD 7~w: ADDRESSABLE FIRE ALARM BG-121XAddressable CONTROL PANEL Manual Pull Station MS-9050UD I Fire Alarm I Control Panel I ft: CL ANN-80 PrinterSD355 Photo Detector Gateway ANN-S/PG PROGRAMMING AND SOF7WARE Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 20 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PK-CD, containing PK-Plus, sepa- rately). Upload/download system programming locally. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Trouble (yellow) Alarm Silenced signals (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge/Step Alarm Silenced Drill (Manual Evacuate) Reset (lamp test) Product Line Information MS-9050U0(E): Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag contain- ing screws, cables, key, etc., manual. (For MS-905OUDC, refer to DF-60445.) PK-CD: Contains PK-Plus programming software for Win- dows®-based PC computer (cable not included). OP-51050: Optional dress panel for the MS-9050U0. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. 80-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a 66-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB-55F for mounting. BAT Series: Batteries, see data sheet DF-52397. PRTIPK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT, I130ACT-2/21.113 Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- Page 2 of 4— DF-52418:C • 12/16/2009 net internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in turn, mounts to the FACP chassis. Use AC-TRMBLK when wire nuts are not allowed for AC connections to the transformer. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS ANN-80(-W): Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shieldid. (Basic model is red; order -W version for white; see DF-52417.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Printer Gateway module pro- vides a connection for a serial or parallel printer. (See OF- 52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. S0355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fast-response, low-profile heat detector that activates at 1900F1880C. AD355: Low-profile, intelligent, 'Adapt" multi-sensor detector (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sen- sitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector housing; includes SD355. DNR: Innovair Flex low-flow non-relay duct-detector housing. (Order SD355 separately.) DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355 separately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) bC. MDF400: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style 0 option. Connects with wire pigtails. May mount in device backbox. MMF-302A: Similar to MMF-300A. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires reset- table 24 VDC power. Refer to the Device Compatibility Docu- ment for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style V/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. - 1300: This module isolates the SLC loop from short circuit condi- tions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CH S-6 chassis in a BB-6F cabinet. CMF400-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9050U0, see the following data sheets (document numbers): AD355 (DF-52386), BG-I2LX (OF- 52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ CRF Series (DF-52130), CP355 (DF-52383), D350PL(A)/ D35ORPL(A) (DF-52398), H355 Series (DF-52385), 1300 (OF- 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), S0355/5D355T (OF- 52384). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): 47k ohm supervises the MMF-300, MDF-300, MMF-301, and CMF- 300 module circuits. 3.9k ohm End-of-Line Resistor assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. DF-52418:C • 12/16/2009 - Page 3o14 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits ......................................... 1 Addressable device capacity..............................................50 Programmable software zones...........................................20 Annunciators.........................................................................8 Electrical Specifications AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-9050U0E: 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (MS-9050U0 cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides con- nections for two NACs, Style V (Class B) or. Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 A. End-of-Line Resis- tor: 4.7 kohm, ½ watt (PIN 71252 UL listed) for Style V (Class B) NAC. Refer to the Fire.Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A 0 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26° (48.92 cm.) high x 16.82° (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65° (42.29 cm.) wide x 5.25 (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65° (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the systems standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F. NFPA Standards The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD(E) control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:210 MEA: 442-06-E NOTE: See DF-60445 for ULC-listed model. FlreLlte® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. 1~1 • •131 We cannot cover all specific applications or anticipate all requirements. MEIFflINE &MANIFACIIRINE All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52418:C • 12/16/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0210 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Model MS-9050U0 addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise),automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart penod shall not exceed 30 seconds. 07-07-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed IN the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Nominal Voltage ......................................................................... 12 volts (6 cells) Nominal Capacity 20-hr. (450 mA to 10.50 volts) .......................................................9.00 AH 10-hr. (810mA to 10.50 volts) .........................................................8.10 AH 5-hr. (1.44A to 10.20 volts) ...........................................................7.20 AH 1-hr. (5.4A to 9.00 volts) ..............................................................5.40 AH 15-mm. (14.4A to 9.00 volts)..............................................................3.60 AH Approximate Weight ...........................................................6.00 lbs. (2.72 kg) Energy Density (20-hr. rate) ..............................1.92 W-h/in3 (116.94 W.h/l) Specific Energy (20-hr. rate) .............................18.00 W-h/lb (39.68 W-h/kg) Internal Resistance (approx.) ......................................................13 milliohms Max Discharge Current (7 Mm.) ................................................27.0 amperes F2- Quick disconnect tabs, 0.250" x 0.032" - Mate with AMP. INC FASTON "250" series 1-3.4-I E:A T 6.35 1-7.95-1 I ii 11 =0.8 -v 1=1 fl HI H MODEL PS.1Z fl I L____ L: 5.95(151) W. 2.56(65) H: 3.70(94) HT: 3.86(98) Battery MODEL E I IFNI 09 Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.0.T., l.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 Max Short-Duration Discharge Current (10 Sec.)..................90.0 amperes Shelf Life (% of nominal capacity at 68°F (200c)) 1 Month ......................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Range Charge .. ........................................................... -4°F(-20°C)to 122-F (50-C) Discharge ....................................................... 40°F(-40°C)to 140°F (60°C) Case......................................................................................................ABS Plastic Tolerances are +1- 0.04 in. (+1- 1mm) and +1- 0.08 in. (+1- 2mm) for Power-Sonic Chargers ................................................ PSC-12800A, 12800A-C height dimensions. All data subject to change without notice. Discharge Characteristics 14.0 Ill Ill I -- Ambient Temperature 20°C (68°F 13.6 - - - - - - -Hr- - - - - ZZ 12.0 Thu .S 10.0 0911 ,! 9.6 - -. - - - ..4.5 - - - - FInal 90 8.0 - Voltage - - - - - - III 18 1.2 2.4 6 12 24 36481 2 4 6 810 20 40 H mm .Ia h In Discharge Time Life Characteristics in Stand-By Use 100 I I I I Ambient Temperature 20°C (68°F) I Float Charging Voltage 2.25 - 2.30 VlCell 0 1 2 3 4 Years Life Characteristics in Cyclic Use Discharge Discharge Discharge Depth 100% Depth 5 Depth 30% Discharge current o.c (Final Voltage 1.7v1ceu) Charge Current 0.IC I Ambient Temperature: 20°C to 25°C (68°F to 77°F) I I I I I I 200 400 600 800 1000 1200 Number of Cycles 120 100 80 U 0 60 C., C .2 40 a' C 20 0 0 10 05 E I- a, 2 2' II U I U) 30 E (68°F) T 20 --- 15 El. ilEilE 100 so III I 10 (104°F) I.._ I.. I _____ (32°F) Shelf Life & Storage chs tenc. r 33k, necessary union tQ0%ofcapaci is required. N 5°C charging berare - - - - (4fF) I \. N fuIlCaty. 80 use Is necessary to this state. - C 30 C 20 C capacity. Do not I OramayraI 40° I maim - - (104°F) _(86°F) - (68°F).-1-- lot batteries Standing Period (Months) Discharge Time vs. Discharge Current -; 100 .2 CL 0 2 4 6 8 10 12 14 16 18 20 0.45 0.90 1.8 4.5 9.0 18 Discharge Current (A) Cycle Applications: Limit initial current to 2.7A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 90mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to "float" voltage. "Float" or "Stand-By" Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for 'C-Series downloads, such as product catalogs, material safety data sheets (MSDS), ISO Switch Mode Chargers" and 'Transformer Type A and F Series". Please contact our certification, etc.. Technical department for advice if you have difficulty in locating suitable models. ANN-80 80-Character LCD Serial Annunciator 8 FureLuTeALarms by Honeywell df-52417:c • B-go nnu The ANN-80 annunciator is a compact, backlit 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-805 may be connected to the ANN-BUS of each FACR No programming is required, which saves time dur- ing system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset Control switches can be independently enabled or disabled at the FACR Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4° square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KlT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption 0 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 490C). Relative humidity: 93%* 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. in some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. df-52417:c • 05/22/09 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge . Current Draw (amps) 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. * 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1.493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power I wiring are supervised I __ and power-limited. ANN-BUS Device 12345678 FACP Wiring to ANN-BUS Device ORDERING OPTIONS: ANN-SO: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SBBOKIT-R: Red surface mount backbox with angled wedge. ANN-SBBOKIT-W: White surface mount backbox with angled wedge. FireLite® Alarms is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 - We try to keep our product information up-to-date and accurate. : . We cannot cover all specific applications or anticipate all requirements. BlN!flI S MANUFRI1URINI All specifications are subject to change without notice. QUALITY SYSTEMS . Made in the U.S. A. For more information, contact FiresLite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com - Page 2 of 2— df-52417:c • 05/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120 --ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2@Honeywell.com DESIGN: Model ANN-80 and *ANN BOW remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh * This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 3O,2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SD355(A), SD355T(A), SD355R(A) Addressable Photoelectric Smoke Detectors df-52384:b • E-160 (a FlreLrreALarms by Honeywell AressaIDiZ'"1 ri ,E:1 The SD355(A) and SD355T(A) addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire'Lite's Address- able Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (570C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (P/N RA1 OOZ(A)). The SD355R is a remote test capable detector for use with D355PL or DNR(W) duct smoke detector hous- ings. Features SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with MS-9200 series, and 01 - 159 with MS-9600 series. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED 'blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-Va plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA1 OOZ). SD355 with B350LP base SD355T with B350LP base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white LEXAN®. SD355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation SD355(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SW loop, end-of-line resistors are not required. Wiring 71aps" or branches are permitted for Style 4 (Class B) wiring. SD355R mounts in a D355PL or DNR(W) duct detector housing. df-52384:b • 3/12/10 - Page 1 of 2 Operation Each S03551T/R uses one of 99 possible addresses on the MS-9200 series and up to 318 (159 on each loop) on the MS- 9600 series Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The SD355/T/R addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar chamber, the SD355/T/R is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200 series or MS-9600 series addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200 series or MS- 9600 series for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 300 pA 0 24 VDC. LED current: 6.5 mA 0 24 VDC (latched "ON"). Air velocity: 4,000 ft./min. (20 rn/sec.) maximum. Diameter: 6.1" (15.5 cm) installed in B350LP base. Height: 2.1" (5.33 cm) installed in B350LP base. Weight: 3.6 oz. (102 g). Operating temperature range: for S0355(A): 0°C to 49°C (32°F to 120°F); for S0355T(A): 0°C to 38°C (32°F to 1000F). SD355R(A): installed in a DNR(W) -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 1200F). Relative humidity: 10% - 93%, non-condensing Listings Listings and approvals below apply to the SD355(A) and SD355T(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed, file S1059; ULC Listed, file S1059. CSFM approved: file 7272-0075:194. MEA approved: file 243-02-E. FM approved. Product Line Information NOTE: "A" suffix indicates ULC-Listed model. SD355: Adressable photoelectric detector; B350LP base included. SD355A: Sames as SD355 with ULC Listing (B350LPA base included). 5D355T: Same as SD355 but with thermal element; B350LP base included. SD355TA: Same as SD355T with ULC Listing (B350LPA base included). SD355R: Remote test capable addressable photoelectric detector for use with a 0355PL or DNR(W) duct detector hous- ing. B35OLP(A): Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224R6(A): Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 Cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B200SR: Sounder base capable of producing temporal-3 or steady sound output. ACCESSORIES: RA1 OOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and 8350LP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with 8501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010:Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. FlashScan® registered trademark of Honeywell International Inc. Bay- blend® is a registered trademark of Bayer Corporation. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 1=1 • •131 We cannot cover all specific applications or anticipate all requirements. B®1N1N a M1IM11UNINI All specifications are subject to change without notice. QUAlITY SYSTEMS For more information, contact Fire.Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2012- df-52384:b • 3/12/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.ReynoIds2©Honeywell.com DESIGN: Models S0350, 5D350T, 5D355, 5D355R*, SD355T and AD355 photoelectric type smoke detectors. Model SD350T and 5D3551 has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models SD355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. Rev. 01-11-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ' the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52013:C • E-100 BG-12LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACP5). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TA). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 pA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TA) may be used. The BG12TR is (J FireLITeALarms by Honeywell F-1 usually needed for semi-flush mounting with 40 (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 40 (10.16 cm) square electrical box, and shall be installed within DF-52013:C • 0910212009— Page 1 of 2 the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: 5711 MEA: 67-02-E CSFM: 7150-0075:184 FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Flre.Llte is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. =1 We cannot cover all specific applications or anticipate all requirements. IMMIM &MJJIIFAI1IJINt All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:C • 09/02/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.ReynoIds2©Honeywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-12LW, BG-12WP, BG-I2LWP, BG-12L, BG-12LX, BG-I2LA, BG-I2PS, BG-I2LSP, BG-12SP, BG-I2LR, BG-I2LRA, BG-I2LAO, BG-I2LAOB, BG-12-LO, BG-12LOB, BG-I2LPS, BG-I2LPSP, BG-I2SL, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 3O,2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division df-52121:al • E-325 MMF.300(A) Series! MDF-300 Addressable Monitor Modules General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire'Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF-300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class 8 Fire uTeALarms by Honeywell de 0 DI 8 j 0 .JfI MMF-300 and MMF-302 2IIL 111112 8 3*1 4 015 A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF.301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. detail of MDF-300 - not "ones" addresses are 4, 6, 8 only df-52121:al • 04/28/08 - Page 1 of 6 High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. 1415 ADDRESS 0 12 3 7 6 LOO o .." 9 8 TENS ONES Il oI c _j liw Go Ilj UJ 10 —jIl 110 I iI The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, watert low devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 cm) deep box. MDF.300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) IDC circuits ONLY. Class A (Style D) IDC circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Maximum operating current: 750 pA (LED flashing). Page 2 of 6— df-52121:al • 04/28/08 Maximum IDC wiring resistance: 1.500 ohms. EOL resistance: 47K ohms. Temperature range: 320 to 120°F (00 to 490C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 2.125° (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 FM Approved CSFM: 7300-0075-185 MEA:72-01-E Product Line Information MMF-300: Monitor module. MMF-301: Monitor module, miniature. MMF-302: Monitor module, two-wire detectors MDF-300: Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. Architects/Engineers' Specifications Specifications of these and all FireLite products are available from FireLite. © CAUTION -__DE-ENERGIZE UNIT PRIOR TO SERVICING Face plate for MMF4100, MMF-302, and MDF-300 Mounting Diagrams for Standard-sized Modules df-52121 al • 04/28/08 - Page 3 of 6 Wiring Diagrams The following wiring diagrams are included: MDF-300: Typical dual two-wire Style B initiating device circuit configuration. MMF-301: Typical two-wire Style B initiating device circuit configuration. MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. MMF-302: Interface two-wire conventional detectors, NFPA Style B. MMF-302: Interface two-wire conventional detectors, NFPA Style D. Applications with Conventional Detectors: Resetting Conventional Detectors Figure 1 MDF-300: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits each power-limited to Device FROM Panel TO Next 230 pA max. @ 12 voc max. Device MODULE 47KEOL ii (2 "Commun or Previous MONITOR Communication Line ELR.47K 0 2 VDC maximum. Resistor Twisted -pair is 8(32 commended. 47KEOL 6 All shown wiring is supervised and power - limited. Resistor ELR.47K — I ASI 5555 Connect modules to listed compatible Fire- Ute control panels only. ANY NUMBER of UL Listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. Install contact closure devices per manufacturer's Installation instructions. e822wlrl.wmf Figure 2 MMF-301: Typical two-wire Style B initiating device circuit configuration. N TO 1 D NEXT EVICE i BLACK1 14 RED UL LISTED Compatible Miniature Monitor Module 4Ii1 13 2 Control I I 56789Ø 4 2'klf Panel 3111 1115112 3 101514 0"(+" (-) - VIOLETI I4 YELLOW 47K EOL INCLUDED 95720w1r1 Page 4016— df-52121:al • 04/28/08 NOTE: Wiring Diagrams this Page: MMF-300 Connect modules to listed compatible FireLite control • Any number of UL-listed contact closure devices may be panels only. used. All wiring shown is supervised and power limited. • DO NOT MIX fire alarm initiating and supervisory devices Install contact closure devices per manufacturers' installa- on the same circuit. tion instructions. Figure 3 MMF-300: Typical two-wire initiating circuit configuration, NFPA Style B. TO Nqxt FROM Panel Device or Previous MONITOR Initiating t (I limited: I L!!222LI I '4 scotion Line Commun Device 32 VOC maximum 801 47K EOL max. Twisted-pair Is recommended. Communication Loss ELR-47K ANAESS (optional connection for panels Resistor which support this feature) :;:) oj FUTURE FEATURE enowus.wms Figure 4 MMF-300: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. TO Next Device - FROM Panel or Previous MONITOR Device MODULE Communication Line 32 VDC maximum. Twisted-pair is EOL Res stor Is Internai at recommended. terminals 8 & 9 Communication Loss (optional connection for panels which support this feature) FUTURE FEATURE evsowlrawms di -521 21:al • 04/28/08 - Page 5 of 6 RELAY CONTROL ODULE (b TO Next Device DC POWER SUPPLY () Listed for Fire (-I Protection with Batter, Backup (—) 4 (+1 4 FROM Panel or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. NOTE: Wiring Diagrams this Page: MMF-302 and CRF-300 Connect modules to listed compatible control panels only. • Detectors must be UL listed compatible with module. Terminal wiring must be power limited. • Install detectors per manufacturers' installation instructions. DO NOT MIX fire alarm initiating and supervisory devices • Power to the interface module must be externally on the same circuit. switched to reset the detectors. An relay control module DO NOT LOOP wire under terminals. Break wire run to can be used to switch power from a standard power sup- provide supervision of connections. ply; see Figure 8 below. Figure 5 MMF-302: Interface two-wire conventional detectors, NFPA Style B. TO Next - FROM Panel Device (+) (+) or Previous INTERFACE Device d MODULE Communication Line 32 VDC maximum. recommended. 3.9K EOL T69 2 Twisted -pair is (;) Listed BatteryBackup Resistor switched D (included)WS power supply. A2143-1O LOOP AOORE$S o - Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. enowlrs.wmf Figure 6 MMF-302: Interface two-wire conventional detectors, NFPA Style D. TO Next - FROM Panel (+1 or Previous Device Device INTERFACE MODULE Communication Line 32 VDC maximum. Twisted-pair s recommended. Listed Battery Backup + switched D2' LP O5 AMESS power supply. oO Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. 67,ti6.w1W Figure 7 Applications with Conventional Detectors: Resetting detectors NOTE: To reset conventional detectors, externally switch off power to the interface module they are connected to. This example shows CRF-300 (see DF-52130). Fire-Lite® and LiteSpeed® are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. csm • • • We cannot cover all specific applications or anticipate all requirements. 111111111MIND a 111INUMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6— df-521 21:al • 04/28/08 CMF and CRF Series Addressable Control and Relay Modules General CMF-300 Control Module: The CMF-300 Addressable Con- trol Module provides FiresLite intelligent control panels a circuit for Notification Appliances (horns, strobes, etc.). Addressabil- ity allows the CMF-300 to be activated through panel program- ming, on a select (zone or area of coverage) basis. CRF-300 Relay Module: The CRF-300 Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, door hold- ers, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTm is a communication protocol developed by FiresLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The CMF-300 module requires power (for horns, strobes, etc.). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). The CMF-300 may be used to switch 24-volt NAG power. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for MS-9600, 01 - 99 on MS-9200UDLS and MS-9050UD. Applications The CMF-300 is used to switch 24 VDC audible/visual power. The CRF-300 may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The CMF-300 is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300 provides two Form-C dry contacts that switch together. DF-52130:A • E-350 FureuTeALarms by Honeywell CMF-300 Module (see wiring diagram Fig. 5 for CRF-300) Operation Each CMF-300 or CRF-300 uses one of 159 possible module addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAG). The LED blinks with each poll received. On command, it activates its internal relay. The CMF-300 supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. NOTE: Open/short supervision is suspended with the CRF-300. Upon code command from the panel, the CMF-300 will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communication loop so that a trouble condition on the external power supply will never. interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identity the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for CMF-300 Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll (CLIP mode), 375 pA group poll (LiteSpeed mode) with LED flashing. External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). DF-52130:A • 6/11/07 - Page 1 of 4 Mounting Diagrams Note CBSOO Module Barrier, which creates isolated quadrant. EN CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 450 (114.3 mm) high x 4° (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125'(53.975 mm) deep box. Specifications for CRF-300 Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 930/6 non-condensing. Dimensions: 4.5° (114.3 mm) high x 4° (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125° (53.975 mm) deep box. RELAY CONTACT RATINGS FOR BOTH CMF400 AND CRF-300 MODELS Load Application Maximum Current Description Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive Coded 30 VDC 0.5 A (L/R=5m5) Inductive Coded 30 VDC 1.0 A (L/R=2ms) Inductive (PF=0.35) Non-Coded i 125 VAC i I 0.5 A I Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: CS3965 FM Approved CSFM: 7300-0075:185 MEA:72-01-E PRODUCT LINE INFORMATION CMF-300: Intelligent Addressable Control Module. CRF-300: Intelligent Addressable Relay Module. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as CMF-300. Page 2 of 4— DF-52130:A • 6/11/07 Wiring Diagrams The following wiring diagrams are provided: CMF-300: Typical notification appliance circuit configuration, NFPA Style V. CMF-300: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. CRF-300: Relay module wiring diagram. Figure 1 CMF-300 Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to Listed Communication Line 32 voc max. compatible Fire'Lite control Refer to pbanel documentation for panels only. TO Next Device ype le required. FROM Panel or Previous All wiring shown is CONTROL Device supervised and power MODULE 24 VDC Circuit limited. 47K EOL DO NOT LOOP wire / or, terminals 3 & 4. Resistor Module polarities are ELR-47K 8 1 Break wire to provide shown in alarm. supervision of connections. 7 2 AMRESS 24 VDC POWER ç O2 SUPPLY (+) Power Supply: UL listed Isolated, regulated. powar-limitad EOL Relay TO NEXT control module or EOL Relay. W protection per NFPA 70. shown ONE RELAY REQUIRED for each circuit. Listed for fire energized Some control panels have the RELAY BUILT IN with battery backup. 24 VDC coil and do not require external wiring. 6724wi,I.wml EOLR-1 Refer to the manual. CMF-300 Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to Listed Communication Line 32 VDC max. compatible Fire•Lite control Refer to panel documentation for panels only. TO Next Device ypa ble required. FROM Panel or Previous All wiring shown is EOL Resistor CONTROL Device supervised and power is internal at MODULE 24 VDC Circuit limited, terminals 8 & 9 / DONOTLOOPwire on terminals 3 & 4 . / Break wire to provide Module polarities are shown in alarm. supervision of connections. 24 VDC LOW AWRESS POWER SUPPLY Power Supply: UL listed EOL Relay TO NEXT control module or EOL Relay. Isolated, regulated. power-limited per NFPA 70. shown ONE RELAY REQUIRED for each circuit. Listed for fire protection energized Some control panels have the RELAY BUILT IN with battery backup. 24 voc coil and do not require external wiring. 67241r2.wml EOLR-1 Refer to the manual. CRF-300 Relay module wiring diagram. Connect modules to Listed - TO Next FROM Panel compatible Fire'Lite control Device , , , or Previous +--------------' (1 . Device panels only. - o Module does NOT RELAY Communication Line supervise controlled I ? I 32 VDC maximum. ) Refer to panel documentation circuits. — o' for type of cable required RELAY COMMONig NORMALLY CLOSED 2 1341'4 1 NORMALLY OPEN 2 7_Il_l 2 RELAY COMMON 1 — 6 NORMALLY CLOSED 4k 3 )NORMALLY OPEN I (ZS LOOP ADDRESS 6724wi,5.wmf'rr "rr'" DF-52130:A • 6111107 — Page 3 of 4 LiteSpeed is a registered trademark of Honeywell International Inc. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 111313= We cannot cover all specific applications or anticipate all requirements. MI?IMINE &MANIMCIIIIINE All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire'Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52130:A '6/11/07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2@Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM SENSOR Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlert6 Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction -Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75,95,110,115,135,150,177, and 185 Horn rated at 88+ ciBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units - Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products - Compatible with MDL sync module The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING (9 <~> USTED APPROVED 54011 (chimes. horn Uobej horns) 3023572 55512 (strobes) MEA approved 7l2Sl6S3l86 )ndoor strobes) 7125-1653103 (mm strobes. MEA02-05-E chireesUob) 7135-1653:I53 (rains. chimes) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back boy, or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75,95,110,115,135,150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411A6 x 4/16 x 21/8-inch back box.The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/F WR1 Operating Voltage Range2 8 to 175 V 02 V nominal) or 16 to 33 V (24V nominal) Input Terminal Wire Gauge 12to18AWG Ceiling-Mount Dimensions (including lens) 6.8diameter x 25 high 073mm diameter x 64 mm high) Wall-Mount Dimensions (including lens) 5.6% x 4.7W x 2.5 D (142 mm Lx 119 mm W x 64mm D) Horn Dimensions 5.6L x4.7Wx 1.3D(142 mm Lx 119 mmWx 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.91 x 5.0W x 2.2"D (151 mm Lx 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 diameter x 2.2 high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS, TRW-HS) 5.7% x 4.8'W x 0.35D (145 mm Lx 122 mm x 9 m D) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS,TRCW-HS) 6.9- diameter x 0.35 Thigh (175 mm diameter 9 m high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P 5, PC, and SC products will operate at 12V nominal only for 15 and 15/75 cd. A05.09S.O7 UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-lemporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 71 Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AOS.0395-07 SpectrAlert Advance Dimensions Wall-mount horn strobes Ceiling-mount horn strobes 7.1W 2.2511 5.05 2.23tj Di p oc 8. II II ri I -iJ I S S LJ Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn Strobes P2R°' 2-Wire Horn Strobe, Standard cdt, Red P2RH 2-Wire Horn Strobe, High cd, Red P2W 2-Wire Horn Strobe, Standard cd, White P2WH 2-Wire Horn Strobe, High cd, White P4R0 4-Wire Horn Strobe, Standard cd, Red P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR°t Strobe, Standard cd, Red SRH*l Strobe, High cd, Red SW Strobe, Standard cd, White SWH Strobe, High cd, White Ceiling Horn Strobes PC2R 2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC2W' 2-Wire Horn Strobe, Standard cd, White PC2WH° 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High Cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Ceiling Strobes SCR Strobe, Standard cd, Red SCRI-1 Strobe, High cd, Red SCW° Strobe, Standard cd, White SCWH Strobe, High cd, White Horns HR Horn, Red HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White Notes: * Add '-rto model number for plain housing (no'FlRE' marking on cover), e.g. P2R-P. t Add '-SPto model number for *FUEGO marking on cover. e.g. P2R-SR *Standard cd' refers to strobes that include 15, 15/75,30,75,95, 110. and 115 candela settings.'High cd refers to strobes that include 135, ISO, 177, and 185 candela settings. C2009 System Sensor. SYSTEIL7 3825 Ohio Avenue. St. Charles, IL 60174 s$ SENSOR Phone: 800-SENSOR2. Fax: 630-377-6495 AOS.039S-07.4109 2132 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix 'P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..JBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three- pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division ;- SYSTEM SENSOR Duct Smoke Detector Accessories Expand the versatility of the lnnovairFlex" line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA1 51 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn, White RA100Z/RA100ZA Remote Annunciator RTS1 51 Remote Test Station RTS1 51 KEY Remote Test Station with Key RTS2 Multi-Signaling Accessory AOS Add-On Strobe RTS2-AOS Multi-Signaling Accessory The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert Advance mini-horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. Agency Listings The RTS151 and RTS1S1 KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS1 51 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. LISTED APPROVED Specifications, Duct Smoke Detector Accessor I1L1I.1IJTZTLli1ilh,Ir4tu.I Voltage Regulated 24VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non-condensing Wire Gauge 12to18AWG Dimensions 4.6-11 x 2.9Wx A50 Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24VDC or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync-Circuit' Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 17.5 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12to18AWG Dimensions 4.&I1x 2.9Wx0.45D Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32VDC Maximum Alarm Current 12 mA & Dimensions 4.6 H x 2W x 1.3 D 7 T RTS151 ULS4O11 RTS1S1 KEY ULS2S22 ___ _ - , •.. .-... - RA100Z UL 52522 MHW UL S4011 'ies Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: lOS mA max. Test Switch 10VA@32VDC Reset Switch 10VA@32VDC Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 14(°F) Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Dimensions 4.8'Hx2.90Wx1.4D RTS 15 1 KEY Remote Test Power Requirements Station with-Key Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm ResponseTime 40 seconds max. Temperature Range —10°C to 60°C (14°F to 14(°F) Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Dimensions RTS2 and RTS2-AOS Multi Voltage 4.6Hx2./5Wx1.8D -signaling Accessory 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8'Wx5.3Hx 1.6D For the very latest product specifications and listing information, please visit the System Sensor Web site at w.systemsensor.com. SMOKE . e- APA151 UL S4011 RTS2-AOS UL 52522 W, MHR UL 54011 AOS "\ Y5TElVi 3825 Ohio Avenue - St. Charles, IL 60174 O2OIO Sys em Senior. Z-10 SENSOR' Phone: 800-SENSOR2 - Fax: 630-3/1-6495 A05.*423.00 I. 2/10-023(19 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models RTSI 51, RTSI 51 KEY and RAI OOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ON the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires JUne 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division II[w]hTyAvNLtIIi GENESIS SERIES 1:00~13NM IN Description: 14 AWG 2/C SQL FPLP-CL2P Compliance: UL Standards 13 & 1424; NEC Articles 725 & 760 Construction: Conductor 14 AWG Solid Bare Copper No. of Conductors 2 Insulation Type Plenum PVC Color BIk, Red Thickness 0.007" nom. Diameter 0.078" nom. Lay Length 3.0" nom. Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.180" nom. Legend (Ink Print) HONEYWELL P/N 4513 2C14 3038058 (ETL) FPLP OR CUP C(ETL)US FT6 75C (RoHS) W/O# XXXXXX-XXXXXX XXXXFT DEVICE/ZONE A B C D E F 12 3 4 5 6 789 Properties: Temperature Rating -20 to 75°C Operating Voltage 300 Volts max. Capacitance 32 pf/ft nom. Impedance 59 Ohms nom. DC Resistance 2.5 Ohms/M' at 20°C Flame Rating UL 910, NFPA 262, C(UL) FT6 REV A 09/01/10 OA VNLe1 III GENESIS SERIES CABLE Description: 18 AWG 2/C SOL FPLP Compliance: UL Standard 1424; NEC Article 760 Construction: Conductor 18 AWG Solid Bare Copper No. of Conductors 2 Assembly Tubed jacket over twisted insulated conductors Insulation Type Plenum PVC Color Bik, Red Thickness 0.007" nom. Diameter 0.054" nom. Lay Length 1.75" nom. Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.134" nom. Legend (Ink Print) HONEYWELL 18 AWG 21c (ETL) FPLPICL2P 3038058 75C W!O# XXXXXX-XXX C(ETL) FTS XXXXFT DEVICEIZONEABCDEFI23456789 Properties Temperature Rating -20 to 75 °C Operating Voltage 300 Volts max. Capacitance 24 pf/ft nom. Impedance 65 Ohms nom. DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 910, CSA FT6 Honeywell GENESIS SERIES CABLE Construction: Conductor 18 AWG Solid Bare Copper No. of Conductors 4 Assembly Tubed jacket over untwisted insulated conductors Insulation Type Plenum PVC Color Bik, Red, YIw, Gm Thickness 0.007" nom. Diameter 0.054" nom" Lay Length Straight Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.156" nom. Legend (Ink Print) HONEYWELL 18 AWG 41c (ETL) FPLPICL2P 3038058 75C WiO# XXXXXX-XXX C(ETL) FT6 XXXXFT DEVICE/ZONE ABCDEFI2345G789 Properties Temperature Rating -20 to 75 °C Operating Voltage 300 Volts max. Capacitance 24 pf/ft nom. Impedance 65 Ohms nom. DC Resistance 6.5 Ohrns/M' at 20°C Flame Rating UL 910, CSA FT6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1487:0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: GENESIS CABLE SYSTEM770I 95TH Street, Pleasant Prairie, WI 53158 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Email: orvillegenesiscable.com DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HOPE or LOPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Giflo/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, Type 'FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct eSV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 . Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division