Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3409 VIA MONTEBELLO; ; FA140099; Permit (2)
5/2/24, 3:57 PM FA140099 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA140099 3409 VIA Job Address: Status: ISSUED MONTEBELLO Permit Type: FALARM Applied 7/8/2014 Parcel No: 2230507200 Approved: 7/16/2014 Lot #: 0 Reference No.: Issued: 7/16/2014 PC #: Inspector: Project Title: 24 HOUR FITNESS INSTALL NEW ADDRESSABLE FIRE ALARM. SYSTEM CONSISTING OF THE EQUIPMENT SHOWN IN THE DEVICE LEGEND. PROGRAM THE FACP PER SEQUENCE OF OPERATIONS ON THE PLANS. Applicant: JJJ ENTERPRISES. 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: PROPERTY DEVELOPMENT CENTERS L L C C/O SAFEWAY INC 5918 STONERIDGE MALL RD PLEASANTON CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 286 0 286 0 about:blank 1/1 FILE Copy IFIRPAP EKuEpp1qsE2 FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS 24 HOUR FITNESS 3409 VILLA MONTEBELLO CARLSBAD, CA. FIRE ALARM SYSTEM MATERIAL DATA SHEETS I'lle-w plams have K-ev reviewed for UPPill-cill compliance nith cue cirren; applicable cisjcs ;cc'.d .iaul(ial ch in filice I In l!ii' lui1:4IIClccHc the 0WI1CI (5 CiiliIlCIiir 111.1% tiiiiii. IL'I(•W in suppiri cii ;i,i nppice.iihn 1111. hiiikiiii5 11111 iii,, lice ei)iLss Unii.rsiiiicitjii.. tii;ii ili. riiew 0 ico w,iv relieves lice owner icr conlraclor or their iurslccc:ui euuiucecu icr ;urcliiiixi fi sole cespucuusihilii It .i• 11111 (cuuiupliafleC with said cucks and stauudzurcls. calcite he huukiiuue code cur icr any respicucaibdir for dt-ficleficivs. crrucrs. ouicissiuuuc ill- iiiiL'Cuc(C Ili tiics phuics wIciheu cur uoi coded in INS review. [J RECOMMEND RECONINIEND AP}tk( WA!. IE(UMcilNi) APIR()V.\i ..A. NOTE!) I 24 HOUR FITNESS BILL OF MATERIALS FIRE-LITE MS-9200 UDLS INTELLIGENT ADDRESSABLE PANEL CSFM# 7165-0075:0208 FIRE-LITE ANN-80 ANNUNCIATOR CSFM# 7120-0075:0211 FIRE-LITE BG12L MANUAL PULL STATION CSFM# 7150-0075:0184 FIRE-LITE 5D355 ADDRESSABLE SMOKE DETECTOR CSFM# 7272-0075:0194 FIRE-LITE H355 ADDRESSABLE HEAT DETECTOR CSFM# 7270-0075:0195 FIRE-LITE !'24F-300 MONITOR MODULE - CSFM# 7300-0075:0185 FIRE-LITE CRF-300 CONTROL AND RELAY MODULES CSFM# 7300-0075:0185 SYSTEM SENSOR $CW CEILING MOUNT STROBE CSFM# 7125-1653:0186 SYSTEM SENSOR PC2W CEILLING MOUNT HORN/STROBE CSFM#7125-1653:0188 SYSTEM SENSOR P2RK WEATHR-PROOF WALL MOUNT HORN/STROBE CSFM#7125-1653:0188 SYSTEM SENSOR SRK WEATHER-PROOF WALL MOUNT STROBE CSFM#7125-1653:0187 MS.9200UDLS(E) Rev 3 Intelligent Addressable FACP with Built-In Communicator General The Fire'Lite MS-9200UDLS Rev 3 with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS Rev 3 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode—Fire•Lite's latest polling technology—for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The MS-9200UDLS Rev 3's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, additional secondary ANN-BUS, and increased power for the resettable and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload! Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools—the Fire-Lite Upload/Download software kit—may serve as a Service Termi- nal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, AD355 (LiteSpeed), USB port, NAC circuit diagnostics, a new report has been added to the walk- test that lists untested devices, new device types added: audio telephone type code for ACC 25!50ZST, Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACP5 (Fire Alarm Control Panels). DF-60601:A1 • Al -60 (a Flre,LITeeALarmS by Honeywell Features . Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four (4) Style V (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or LCD-80F, ANN-80 or Legacy ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - ANN-80(-W) Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module alarms only - ROME Relay Option Module Enclosure ACS/TERM: - ACS Annunciators: Up to 32 Legacy ACM Series annun- ciators (ACM-1 6AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. - Terminal-mode Annunciators: Up to 32 Legacy LCD-80F remote annunciators. DF-60601:A1 • 12/07/2010 - Page 1 of 6 ElA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6F. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1.000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE. Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information MS-9200UDLS: 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 120 VAC operation. MS-9200UDLSE: Same as MS-9200UDLS, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style V (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PK-CD Programming software for Windows®-based PC com- puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-1 20F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 3(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming and updating panel firmware. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IR (See data sheet DF-60407 or DF-52424 for more information.) Page 2 of 6— DF-60601:A1 • 12/07/2010 IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. IPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed On the FACP LCD dis- play. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) DNRW: Innovair Flex low-flow non-relay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order SD355R sepa- rately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. ANN-LED: Annunciator Module provides three LEDs for each MMF-301: Miniature version of MMF-300. Excludes LED and zone: Alarm, Trouble and Supervisory. Ships with red enclo- Style D option. Connects with wire pigtails. May mount in sure (see DF-60241). device backbox. ANN-RLED: Provides alarm (red) indicators for up to 30 input MMF-302: Similar to MMF-300, but may monitor up to 20 con- zones or addressable points. (See DF60241). ventional two-wire detectors. Requires resettable 24 VDC ANN-RLV: Relay Module, which can be mounted inside the power. Consult factory for compatible smoke detectors. cabinet, provides 10 programmable Form-C relays. (See OF- 5243 1.) ROME: Relay Option Module Enclosure. Provides one ANN- RLY Relay Module already installed. The ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi-module. (See Installation Sheet PN 53530.) ANN-SIPG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom* graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS Rev 3, see the following data sheets (doc- ument numbers) ACM-8RF (DF-51555), ACS/ACMSeries (DF- 52378), LDM Series (DF-51384). LCD-80F (DF-52185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. SD355R: Addressable remote test capable detector for use with D355PL or DNR(W) duct smoke detector housings. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355H1: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile, intelligent, "Adapt" multi-sensor detec- tor (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector hous- ing. SD355R included. DF-60601:A1 • 12/07/2010— Page 3 of 6 CMF-300: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 opera- tion). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-617. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-617. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS Rev 3, see the following data sheets (document numbers): AD355 (DF-52324), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-60379), CMF/CRF Series (DF-52 130), CP355 (DF-52383), D355PL (DF- 52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 SerieslMDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), S0355/SD355T (DF-52384). 2) Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)/ SD350(7) and older modules such as the M300, M301, M302, C304, and BG-IOL)( are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard LiteSpeed protocol. Please consult factory for further information on previous 300 Series devices. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. Page 4of6—DF-60601:A1 • 12/07/2010 DF-60601:A1 • 12/07/2010 —Page 5ot6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits . 1 Addressable device capacity..........................................198 Programmable software zones.........................................99 ACS Annunciators............................................................32 ANN-bus devices..............................................................16 Electrical Specifications AC Power: MS-9200UDLS Rev 3:120 VAC, 60 Hz, 3.0 amps. MS-9200UDLS Rev 3E: 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require an external battery charger such as the CHG- 75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) for a total of four Style V (Class B) or with an optional ZNAC-92 module con- verts to four Style Z (Class A) NACs. Maximum signaling cur- rent per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to panel documentation and Fire -Lite Device Compatibility Docu- ment for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps © 30 VDC (resistive), 0.5 amps © 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each output. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26° (48.92 cm.) high x 16.82° (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 16.65° (42.29 cm.) wide x 5.20 (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00° (50.80 cm.) high x 22.5° (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 270C/60 - 80°F. NFPA Standards The MS-9200UDLS Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS Rev 3 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S624 FM approved CSFM: 7165-0075:0208 MEA: 120-06-E For ULC-listed version, see DF-60599. FireLite® Alarms® is a registered trademark of Honeywell International Inc. Wheelocs® is a registered trademark of and ExcederTM is a trademark of Cooper Notification. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. "I MElN!BING a MMUMMI11119 All specifications are subject to change without notice. QUALITY SYSTEMS made in the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6- DF-60601 Al • 12/07/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING. SERVICE LISTING No. 7165-0075:0208 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Models MS-9200UD and MS-9200UDLS addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories.. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Ms..9200UDLs panel also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM # 6911-0075:0226). This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev 11-112.13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: January 17, 2014 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52185:C • B-150 LCD-80F 80-Character Liquid Crystal Display Remote Fire Annunciators (a Flre•uTeALarms by Honeywell Annunci The LCD-80F is a compact, cost-effective, 80-character, back- lit LCD remote Fire Annunciator for use with the Fire•Lite MS- 9200UD Series and MS-9600 Series Fire Alarm Control Pan- els (FACPs). The LCD-80F displays complete system point status information and includes control switches for remote control of critical system functions. Up to 32 LCD-80Fs may be connected onto the ElA-485 termi- nal port of each FACP. The LCD-80F requires no program- ming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. No programming necessary - LCD-80F connects to the terminal port (TB7). Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered from the host FACP or by remote power supply (requires 24 VDC). Up to 32 LCD-80F annunciators per FACR Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from the FACR Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188" (5.556 cm) minimum deep, three-gang electrical box (FiresLite PN 10103) or three-gan- gable electrical switchbox. Surface-mounts to Fire'Lite PN SBB-3 surface backbox. Operation The LCD-80F annunciator provides the FACP with point annunciation with full display text on an 80-character LCD dis- play. The LCD-80F also provides an array of LEDs to indicate system status, and includes control switches for remote control of critical system functions. The LCD-80F provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the LCD-80F use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an ElA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communications (two in and two return); and two for the 24 VDC regulated power. Dip switches control local functions such as: piezo dis- able, control switches/key-switch disable, transmit/receive mode. FEE. ALARM AP4RIT0f " . II. •ui tS\ LCD-80F Installation The LCD-80F can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box (FiresLite PN 10103) or three-gangable electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount appli- cations. Product Line Information LCD-80F: 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key-switch lock. LCD-BOFC: ULC-listed version; see DF-60576 for details. 10103: Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S232 MEA Listed: 72-01-E CSFM: 7120-1574:179 FM Approved NOTE: For ULC-listed version, see DF-60576. DF-52185:C "05/17/2010 - Page 1 of 2 LCD-80F TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft. (1828.8 m) between EACH DEVICE in the EIA-485 loop Terminal Mode EIA-485 (2-wires) _________ 101 BBBO BE 24 VDC (2-wires) Up to 6,000 ft. (1828.8 m) / back from last device EIA-485 loop Me S c.~E_:i' / to end of Terminal Mode EIA-485 return (2-wires) Addressable Fire Alarm Control Panel NOTE: EIA-485: Maximum of 6,000 feet (1828.8 m) cable length from FACP to LCD-80F annunciators, 6,000 feet cable length between each LCD-80F and 6,000 feet from the last LCD-80F back to the FACP. Circuit is power-limited. Up to 32 LCD-80F annunciators may be used on the EIA-485 circuit. When multiple LCD-80Fs are used, the FACP will require additional power supplies (refer to panel documentation). Between each LCD-80F annunciator are four wires: a twisted-shielded pair for data communications and a pair for 24 VOC power. The return circuit only requires two wires (twisted) for data communication supervision, wired from the last LCD-80F annunciator on the loop. Mounting To Backbox(es) The LCD-80F annunciators can be semi-flush mounted in a three-gang electrical box with a minimum depth of 2.188" (5.556 cm) (FiresLite PN 10103). The LCD-80F annunciators can be mounted in three-gangable electrical switchboxes connected together. NOTE: Alternately, LCD-80F annunciators can be mounted to the SBB-3 surface backbox for surface-mount applications. NOTE: This annunciator may not fit easily into a standard 3-gang electrical box if locking clamps are used to secure wiring entering the rear or side knockouts. Only use the TOP or BOTTOM knock- outs to bring wiring into a standard 3-gang electrical box. FIRE ALARM ANNUNCIATOR EZE111111 man slim min I OEM FIRE-LITE ALARMS, INC. Eb SYSTEMS ALL NORMAL -7 11:06A 032001 S S 99 S {;_] V. V ( no (14.764 cm) wide x 4.0" (10.16 cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (Fire-Lite PN 10103, shown above). Fire-Lite® Is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 111111HEINS &MNUMC1URINf All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52185:C • 05/17/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of I CATEGORY: 7120 --ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Model ANN-80 and *ANN80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interlace employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. NOTE: *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52013:C1 • E-100 BOil 2LX FureuTe'ALarrns Addressable Manual Pull Station by Honeywell General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an - addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section .4.1:3[13D; meets ADA requirement for5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SIC loop current: 230 pA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4 (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG1 2TR) may be used. The BG 12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within DF-52013:CI • 8/16/10 - Page 1 of 2 the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S711 MEA: 67-02-E CSFM: 7150-0075:0184 FDNY: FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Flre.Llteis a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. E111111119FRINI S MANIIIACIUBINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:C1 • 8/16/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-12LW, BG-I2WP, BG-I2LWP,BG-12L, BG-I2LX, BG-12LA, BG-I2PS, BG-I2LSP, BG-12SP, BG-12LR, BG-I2LRA, BG-I2LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-I2LPS, BG-I2LPSP, BG-I2SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-I0 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-I0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SD355(A), SD355T(A)5 df-52384:b • E-160 SD355R(A) Fire LITeALarms Addressable Photoelectric Smoke Detectors by Honeywell r1 General The SD355(A) and SD3551(A) addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's Address- able Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (PIN RA1 OOZ(A)). The SD355R is a remote test capable detector for use with D355PL or DNR(W) duct smoke detector hous- ings. Features SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry, of address: 01 - 99 with MS-9200 series, and 01 159 with MS-9600 series. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: ' Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA1 OOZ). SD355 with B350LP base SD355T with B35OLP base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white LEXAN®. SD355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation 5D355(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class B) wiring. S0355R mounts in a D355PL or DNR(W) duct detector housing. df-52384:b • 3/12/10 - Page 1 of 2 Operation Each SD355/T/R uses one of 99 possible addresses on the MS-9200 series and up to 318 (159 on each loop) on the MS- 9600 series Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The SD35511/R addressable photoelectric sensors unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the SD355/T/R is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200 series or MS-9600 series addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200 series or MS- 9600 series for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 300 pA 0 24 VDC. LED current: 6.5 mA 0 24 VDC (latched ON"). Air velocity: 4,000 ft/mm. (20 m/sec.) maximum. Diameter: 6.1° (15.5 cm) installed in B350LP base. Height: 2.1° (5.33 cm) installed in B350LP base. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32° F to 100°F). SD355R(A): installed in a DNR(W) -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 1200F). Relative humidity: 10% - 93%. non-condensing. Listings Listings and approvals below apply to the 5D355(A) and SD355T(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed, file S1059. ULC Listed, file S1059. CSFM approved: file 7272-0075:194. MEA approved: file 243-02-E. FM approved. Product Line Information NOTE: "A" suffix indicates ULC-Listed model. SD355: Adressable photoelectric detector; B350LP base included. SD355A: Sames as SD355 with ULC Listing (B350LPA base included). 5D355T: Same as SD355 but with thermal element; B350LP base included. SD355TA: Same as SD355T with ULC Listing (B350LPA base included). SD35SR: Remote test capable addressable photoelectric detector for use with a D355PL or DNR(W) duct detector hous- ing. B35OLP(A): Plug-in detector base. Dimensions: 6.1° (15.5 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB(A): Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0"(10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, or 3.5° (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224B1(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter: 6.2' (15.75 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, or 3.5° (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5° (3.81 cm). B200SR: Sounder base capable of producing temporal-3 or steady sound output. ACCESSORIES: RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B35OLP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-1 27-010: Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. FlashScan® registered trademark of Honeywell International Inc. Bay- blend® is a registered trademark of Bayer Corporation. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Is0 00i We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 0111ING111111 S 111011118711111111 All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2- df-52384:b • 3/12/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0194 -Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Models SD350, SD350T, S0355, SD355R*, SD355T and A0355 photoelectric type smoke detectors. Model SD350T and SD355T has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models SD355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. Rev. 01-11-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52385:D • E-710 H355(A) Series 8 FlreLure°ALarms AkI U. U Thermal Detectors by Honeywell General - The Fire'Lite Alarms 11355(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors provide open- area protection and are intended for use with Fire'Lite's addressable Fire Alarm Control Panels (FACP5). The H355(A) and 11355R(A) sensors provide fixed tempera- ture alarm detection at 135°F (570C). The H355R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The H355HT(A) is a fixed high-tempera- ture detector that activates at 190°F (880C). These thermal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory, the RA100Z. Features SLC loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Rotary, decimal addressing: 01 - 159 with MS-9600 series, 01 —99 with MS-9200 series. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise triggers at 15°F (8.3°C) per minute for the H355R(A). 3600-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. Visible LEDs "blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. Low standby current. 1 --.- -.,---.. H355(A) in B2IOLP(A) Base 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA1 OOZ remote LED annunciator. Flanged surface mounting kit. Installation H355(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5 (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white fire-resistant plastic. The H355(A) Series plug-in intelligent thermal detec- tors are designed to commercial standards and offer an attrac- tive appearance. Operation Each H355(A) Series detector uses one of 159 (MS-9600 series) or 99 (MS-9200 series) possible addresses on a con- trol panel SLC loop. It responds to regular polls from the con- trol panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimu- lates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The H355(A) Series offers features and performance that represent the latest in thermal detector technology. DF-52385:O • 5/17/2013 - Page 1 of 2 Spefications Size: 2.1" (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501(A): 4.1" (10.4 Cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Installation temperature: - H355(A), H355R(A): —4°F to 100°F (-20°C to 380C). - H355H1(A): —4°F to 150°F (-20°C to 660C). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA 0 24 VDC. Mounting: B21OLP(A) flanged base, included. See "Product Line Information: Intelligent Bases" if using a different base. Fixed-temperature setpoint: 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H3551-IT(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the H355(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2517. ULC Listed (models H355A, H355RA, H355HTA). CSFM approved: 7270-0075:0195. FM approved. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed mode!. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B21OLP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A 0 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A 0 30 VDC inductive. B224B1(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F1I0: Retrofit flange to convert B21OLP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of Fib; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. Product Line Information XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 NOTE: "A" suffix indicates ULC Listed modeL m) sections. H355: Intelligent thermal sensor; 135° F (57° C); B21OLP base T55-127-01O: Detector removal tool without pole. included. H355A: Same as H355 but with ULC Listing; B21OLPA base included. H355R: Same as H355 with rate-of-rise feature; B21OLP base included. H355RA: Same as H355R but with ULC Listing; B21OLPA base included. H355HT: Intelligent fixed high-temperature thermal detector; 190° F (88° C); B21OLP base included. H355HTA: Same as H355HT but with ULC Listing; B21OLPA base included. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. @2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. RN We cannot cover all specific applications or anticipate all requirements. BlNllRlNG I!AANUM11IRING All specifications are subject to change without notice. QUAlITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52385:D • 5/17/2013 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0075:0195 Page 1 of I CATEGORY: 7270-- HEAT DETECTOR LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models H350, H355, and H355HT fixed temperature heat detectors. Models H350R and H355R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: H350, H355, and H355HT 135° F fixed temperature H350R and H355R 15° F rate-of-rise H355HT 190° F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. NOTE: Rev. 05-06-05JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ll an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DF-52121:C • E-325 MMF.300(A) Series, MDF.300(A) 8 FlreuTeALarms hi Wrric!AI&I Addressable Monitor Modules Y General Four different monitor modules are available for Fire'Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301 (A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D used to super- vise a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301 (A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTm is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. designs. MMF.300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 onMS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit MMF-300(A) (Type H) may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DF-52121 :C • 10/06/2010 - Page 1 of 4 MMF-301 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems 1415 0 1W.." ADDRESS 0 1 2 2 11 243 LOOP 3 8 7 8 76 1 I TENS ONES oil LU It-) -i'l ll LU .jI1 0 Ii Icx The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301 (A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF-302(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF402(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 cm) deep box. Page 2 of 4— DF-52121:C • 10/06/2010 MDF.300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style 0 (Class A) lOG circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1.500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 2.125° (5.398 cm) deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address 26", then it will automati- cally assign itself to addresses '26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125° (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-hmited wiring only. The MMF-301 (A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM Approved CSFM: 7300-0075:0185 MEA: 72-01-E DF-52121 :C • 10/06/2010- Page 3 of 4 Fire-Lite® and LiteSpeedtRi are registered trademarks and FireWatch is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO9001 We This document is not intended to be used for installation purposes. In • try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. MIINlN &MMUMCTURING All specifications are subject to change without notice. . Made in the U.S. A. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— OF-52121:C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE . LISTING No. 7300-0075:0185 . Page 1 of I CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIESIMISC. DEVICES LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06.05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PA RSEGIA N, Program Coordinator Fire Engineering Division df-60379:A1 • E-400 CRF300(A) FlreuTe'ALarms Relay Module by Honeywell - Addressable Devices The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTm is a communication protocol developed by Fire'Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. of Wid I %A CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 930/6 non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (UR=5ms) Coded 30 VDC 0.5 A Inductive (LIR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) I Non-Coded 125 VAC 0.5 A df-60379:AI • 08/04109 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: 52424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LlteSpeed'TM is a trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. ffcr% • We cannot cover all specific applications or anticipate all requirements. INSINIGNINS & MNHFAC1URING All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2012— df-60379:AI • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION• OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of I CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2HoneywelI.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. SPKTRAAert Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15175 candela Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75,95,110,115.135.150,177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings; wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage, SpectrAlert Advance utilizes a universal mounting plate Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring, so installers can test wiring Compatible with MDL sync module continuity before the device is installed. Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Aaencv Listinas SIGNALING @ LISTED <j~> APPROVED MEA approved 7125-653:185 (indoor strobes) 7 25-1653188 (horn strobes. S4011 (chimes, horn nooses. horns) 3023572 S5512 (strobes) M5A452-05-E chime strobes) 7135-1653:189 (Corns. chimes) SpectrAlert Advance Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/24nch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitT° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150. 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On tour-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) 6.8-diameter x 2.5-high (173 mm diameter x 64mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 "diameter x 2.2Thigh (180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, 6.9-diameter x 0.35-high (175 mm diameter x 9 m high) TRCW-HS) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P. S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSOO5OI UL Current Draw Data uI• Current 1p•J1vz(uyI:fflI1 Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 UE Max. Current Draw (rnA DC Input 185 RMS), 2-Wire Horn 8-17.5 Volts 15 15/75 Strobe, NA Standard 16-33 Volts 15 NA Candela Range (15-115 cd) 15/75 30 75 286 95 110 258 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 16-33 Volts 135 150 Strobe, 177 High Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant DC FWR Anechoic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 all Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. AVDSOQ5O1 SpectrAlert Advance Dimensions Di Ceiling back box skirt Ceiling-mount horn strobes SpectrAlert Advance Ordering Information -Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2R* 2-Wire Horn Strobe, Standard Cd, Red SCR Strobe, Standard Cd, Red PC2RH 2-Wire Horn Strobe, High Cd, Red SCRH Strobe, High Cd, Red PC2W*t 2-Wire Horn Strobe, Standard Cd, White SCW Strobe, Standard Cd, White PC2WH 2-Wire Horn Strobe, High Cd, White SCWH Strobe, High Cd, White PC4R 4-Wire Horn Strobe, Standard Cd, Red Accessories PC4RH 4-Wire Horn Strobe, High Cd, Red BBSC-2 Back Box Skirt, Ceiling, Red PC4W 4-Wire Horn Strobe, Standard Cd, White Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- Trim Ring, Ceiling, White HS Notes: *Add -P to model number for plain housing (no FIRE" marking on cover), e.g., P2R-P. t Add "-SP" to model number for 'FUEGO" marking on cover, e.g., P2R-SP. t "Standard Cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150. 177, and 185 candela settings. 5YS7EIIJ1 3825 Ohio Avenue • St. Charles, IL 60174 02012 system Product speciticalt009 subject to change notice, vet systemsenser.com 5I'J5OR Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDSO0601 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15,15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185cc1 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.Iinhart©systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..\4BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three- pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert@ Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNAUNG (:)F M IYIEA 7350:1653 187 (outdoor strobes) USTED 7125 653,188 (horn strobes, S4011 (chimes, horn strobes, horns) -PROVED approved chime Strobes) $3593 (outdoor and uteri strobes) 3023572 M6A452'05-E 7135-1653189 (horns, chimes) W F S SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white.or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 34-inch top and bottom conduit entries and 34-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync'Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module. 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DCIFWR or regulated 24 DCIFWR' Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6L x 4.7"W x 2.5D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4.7W x 1.3D (142 mm Lx 119 mm x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7L x 5.1 -W x 2.0'D (145 mm Lx 130 mm x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S. PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSOI2OI UL Current Draw Data .ui.Max. Strobe Candela Currentii.mznw:ii 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 tUL Max. HornICurrent lDrawII 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 185 UL Max. Current Draw (mA DC Input NA NA RMS), 2-Wire Horn 8-17.5 Volts 15 15175 286 Strobe, 258 Standard 16-33 Volts 15 Candela Range (15-115 cd) 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (rnA DC Input RMS), 2-Wire Horn 16-33 Volts 135 150 Strobe, 177 High Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 - 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Sound Volts Volts Position Pattern dB DC FWR DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDSOI2OI Strobe Candela rating at -40°F Listed Candela 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1185 Wall-Mount Horn Strobes trproof Back Box SpectrAlert Advance Diagrams 'II Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Wall Horn Strobes II.fl.1l[.1i P2RKt 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WKt 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*? Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHKt Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWKt Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: Add U-P" to model number for plain housing (no FIRE" marking on cover). e.g., P2RK-P. t Add -R to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate. WTP and WTPW. Standard cd" refers to strobes that include 15. 15/75.30. 75. 95. 110. and 115 candela settings. "High cd' refers to strobes that include 135. 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 52012 5yaram Sensor. 5)'5TEIV1 3825 Ohio Avenue • St. Charles, IL 60174 to change vrithout notice. Vitt systernsensar.com, ,.' SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 10r coned product irriormation. including he latest version of (las data shoot. AVDS01201 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION iff -1 My- OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0187 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: . Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 66C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division