HomeMy WebLinkAbout5962 LA PLACE CT; ; AS100172; Permit5/6/24, 5:10 PM AS100172 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5962 LA PLACE CT Permit Type: SPRINK Parcel No: 2120620600 Lot #: 0 Reference No.: Permit No: AS100172 Status: ISSUED Applied 12/15/2010 Approved: 12/15/2010 Issued: 12/15/2010 PC #: Inspector: Project Title: CAMPUS SUITE 240 T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS. Applicant: Owner: COSCO FIRE PROTECTION CAMPUS CARLSBAD L L C 10695 TREENA ST C/O NEWPORT NATIONAL CORP SAN DIEGO, CA 1525 FARADAY AVE #100 CARLSBAD CA 858-444-2000 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 .0060 I cosco see • 'a I•. Fire Protection San Diego Branch Office 10695 Treena Street., Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 Stoic License No: C-16-577621 www.coscofirecom rly MATERIAL SUBMITTAL Date: 12-10-10 The Campus Spec Suites 5962 La Place Court Carlsbad, CA 92008 JOB # 1O.CD-5317 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: LMC Los Angeles 0 San Francisco 0 Orange 0 Fresno 0 San Diego 0 Seattle Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule- l0lSchedule-40 sprinkler pipe from Allied Tube & Conduit, you get UL listed and FM approved products. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1-1/4" - 8') pipe and Sch-40 (1"- 2-1,2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule- 10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements. Superior Coating Our advanced formula mill coating offers a clean, durable surface that is also paintready for custom color applications without special preparation. The internal surface of all black Fire Sprinkler pipe up to 4,5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/schedule-40 pipe are in compliance with the following: ASTM A135 and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets, Hydrostatic Pressure, Side Wall Rupture, Vibration Test. NIPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In;mm In; mm ths!Ftk/m .LbsIFt.kglm - 1.049 1.680 2.05 1 25 26.6 2.5 3.05 - 1W' 1.380 2.270 2.93 1 .32 35.1 4.36 . :4.36 - 1W 1.610 2.720 3.61 1 40 :409 4.0 5.37 - 2.067 3.650 5.13 1 50 52.5 5.4 7.63 -. 21h* 2.469 5.790 7.86 1 6' 62.7. 8.6 11.73 - I! Specifications - - NPS Nominal I.D. Wt. Wt. (H20 Filled) .CRR Inmm In; -mm . thsiFt_kglm thslft kglm 1.442 1.810 2.525 Ths 32 . 36:6 2.7 3.75 . -. 1½' 1.682 2.080 3.04 5.6570 40 -..,:42.7 3.1 4.52 - 2' 2.157 2.640 4.22 4.5827 50 548 3.9 6.28 - 2½' 2.635 3.530 5.89 . 3.5196 65. 66.9 .5.3 8.77 - 3.260 4.330 7.94 2.5550 80 : .j 6.4 11.82 - 4.260 5.610 11.78 1.6020 90 .108.2 ::_8.3 .17.53 5.295 7.77 17.33 1.4874 125 134.5 : :1156 . .58O . - 6.357 9.290 23.03 1.0251 150 . .161.5. 13:8.: .3427 - 8" 8.249 16.490 40.15 1.8365 00 ... .209.5 24.5.. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: cilliecJ Customer Service (800) 882-5543 Fax (708) 339-1806 TUBE & CONDUIT 161005 Lathrop • Harvey IL 6042.6-T 11350 Norcom Rd • Philadelphia PA 19154 I 2525-N 27th Ave. • Phoenix, AZ 85009 554 Component of State of California OSHPD Approved Seismic Restraints System - II! FIG. 98 Size Range - Secures 3/80 thru 7/8" rod in 1° increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98- Rod Stiffener Fig. 98B - Rod Stiffener wlBreak-off Bolt Head Size Range - Secures 3/8° thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health _Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD orojects, please refer to the TOLCO Simin Pgtr,int (i ,irfoIInc bf Finish— Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99- All Thread Rod Cut to Length Fig. 100- All Thread Rod Full Length Size Range - Secures 3/8" thru 11h" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 1'/4 9500 360 1½ 13800 510 D OERCEJMANUFACTURINO FACILITY • 1315 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 600386.5266 vf.w.'tolco.con, 31 Fig. 200 - "Trimline" Adjustable Band Hanger C@N U11701 Fig. 200R (Import) - °Trlmline" Adjustable Band Hanger w/Retalner Ring Size Range - 1/2° thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2°) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21A" thru 8") Spring tension on nut holds it securely in hanger before Installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mu. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31A 2% 400 11 3/4 3/8 8mm or 10mm 31A 21A 400 11 1 3/8 8mm or 10mm 3% 2/a 400 12 1'/4 3/8 8mm or 10mm 3% 2% 400 13 1½ 3/8 8mm or 10mm 37/a 2'A 400 14 2 3/8 8mm or 10mm 41h 3 400 15 2½ 3/8 10mm 55/a 41A 600 27 3 3/8 10mm 5½ 4 600 29 31A 3/8 10mm 7% 51/4 600 34 4 3/8 10mm 7% 5 1000 35 5 1/2 12mm 91/a 61/a 1250 68 6 1/2 12mm 10½ 6P/4 1250 73 8 1/2 12mm 131A 8Y4 1250 136 OFRCEIMANUMCTURINO FACILITY • 1375 SAMPSON AVE. • CORONAS CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE. 600.786.5265 V(MV.IO1Ca.corfl Not lou that 2' rromlnotstdth Ward flooig Product Features No pre-drilling requlrod. Quick to Install using the Sammy Nut Dnverwith an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made In the U.S.A. N U Wbw 8252957 I/4xV. 25 1/4 8003957 G$1200 1/4 x 2 1760 (Ri) 25 125 114 8004957 1/4x3 8O 25 3/8 8000957 GSTJ5 114x314' 564 (314' Ply) 25 125 3B 8007957 G11 1/4 xl 359 25 3/6' - . 8008967 GST20 1/4x2' 1760 (Ri) 850 1475 25 125 JJZ UUL 3/6' 8009925 (25125.380 318x2.112' 2113 (Ri) 1500 25 125 jpo gan 3/8 8069925 0813048 114x3 2080 (FIt) 25 125 J1f 8011925: 1/4 x 4 2180 (Ft) 8012925 GST6O 1/4x6 2230 (F) 25 125 kilr :Mj9.5_:2b1r 1/4 x2' /760 1/2' 8014925 0812.5-3.80 38u2-1I2 2113 (Fr) 25 125 j2_ 80j1.1.1.....2 14x 79- Vj)f/ry 1/2' 8016925 0814 114x4' 2180 (FIr) 25 125 n1t2x tCo.i J&(Wj"Wt 2t z #l4Btach Nut Driver Pat# 8113910 i #148W Red Nut Driver Part# 8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates upto3Wx12pitchrod. • Reim Installation COOL 'Allows 17' defection from vertical. • Made In the U.S.A. 316' 8141957 SH-GST30 114x3 1720(Fl4 1500 1475 25 125 SPECIAl. NUT DRIVER SYSTEM: The nut dMm were desnedwIth aurrique sphl.olrfeatuia which provk1es afaatand safe kistallatlon each thne. When the We of the ddver comes tab contact with the matarlal you are InstallIng Into, cantinne drilling until nut drlverspkis free. Installation Is then complete. warranty requkes the use of the appiopflate nut drIver for lnslatlaticne. F_)i (lid ni,)st tip 1,) d~ld vsi~ uviws)mmyuptl5cl,~~v —1 0 'T (k _ 4 #14 Bioch NutCilver Part # 8113910 Not Ieu thin? iia,iilnilotdth 17) up to tftpe not lens then 1n YAM 4&5p. f t5ninuii 2-lff torn holIsm to I bmrdiIriee.Mhmmn?*om I holIsm to main ihiet DmWmThis I rnqufflotieHentplylo2or IINdarnamoubIpimth,gor, top of stool beams. Product Features -No pm-drilling required. Quick to Instal using the Sammy Nut Driverwfth an 18Vccrdless dr81!drtier. Saves Ome from traditional methods. Reduces Installation cost. Made In the U.S.A. 114 8019957 SWG 200 1!4x2' 1725 (FIt) 25 125 I iixi I ME 318 8021957 SWG20 1d4x2 1725 (F 1050 25 125 #14SWRed I 318 8022925 8WG25-380 318x2-112' 2249 (FIt) 1500 25 - 125 NUtDrIM 10LL. Xriw :1%uc. 11 Insert the approprIate nut Over Into a3180r 12' portable drIll. Insert the S4MMYSinto the #14 (black) nut dnrer (p/n 8113910). Diiy should beln a vertical position. a Push the few ofme nut ruhtto the ,,,,ber. llMrenthe nut driver spins freely on the S4MMYS, stop dflhl and remove. 4. The S4MMYS Is now readyto receree 1/,F, y8l, II? orniefric all l'h,eadrod, bolt stock (The 1/2 requires The#14SWred nut driver) Note: Wm follow the aovelnsfrucIIons then add retainer nut and torque to 20 foot lft hmasiniwn pulk,utbspwmnsteeL Insert the appropriate nut driver into a 3'8or 111 portable OR Insert the S4MMYS into the #I4SWft" nut driver (pin 8114910). IM1hdn1I unit inahwizorata! position and ataright angle to the structural member, begin Installation. When the nut direr spins he on the SAMMYS stop the diii! and The unit is now ready to receive 114 3mormefric all thread rod or bolt stock Note When installlngSR, follow the above InstrucVons then add retainer nut and torque to 20 foot lbs. for mredmumpuJk,utlnpurnsteet SPECIAL NUT DRIVER SYSTEM: The nut drivers were dealgoed with a unique spin-ott feature which presides a fast and safe bistallatlon each tree. When the face of the ddvercomes iota contact with the material you are Installing Into, cm1me drilling until nutdrlverspins free. Installation lsthenconrpiate. Wairanty requires the use of the appropriate nut driver far Inlailalions.