5963 LA PLACE CT; ; FA110047; Permit
5/20/24, 3:11 PM FA110047 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 5963 LA PLACE CT Permit Type: FALARM Parcel No: 2120620900 Lot #: 0 Reference No.: Permit No: FA110047 Status: ISSUED Applied. 6/20/2011 Approved: 6/20/2011 Issued: 6/20/2011 PC #: Inspector: Project Title: NAVTEQ TI STE 200 TI: FIRE ALARM 25 OR LESS DEVICES Applicant: CALIFORNIA COMMERCIAL SECURITY SUITED 4241 PONDEROSA AVE SAN DIEGO, CA 858-503-7500 Owner: BOI CARLSBAD INC C/O LYNN MINNICI P0 BOX 121604 ARLINGTON TX Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 0 about:blank 1/1 FAUoo4- IJi Fire Alarm System Navteq Carlsbad Airport Plaza 5963 La Place Ct. Suite 200 Carlsbad, CA 92008 Customer: Bycor 6490 Mar Industry Place San Diego, CA 92121 (858) 587-1901 Voice (858) 587-1903 Fax Contractor: California Commercial Security 4241 Ponderosa Ave. Suite D San Diego, CA 92123 Sales Contact: Ken Boney (800) 286-2555 x121 Design Contact: Steve Tincup (619) 421-2372 Desk (619) 549-2516 Cell These plan s have been r e v i e w e d f or apparent co m p l i a n c e with the c n n e i i t a p p l i c a b l e codes and s t a n d a r d s i n f o r c e in the tun s d t c t i o n . T h e w n e r o r c o n t r a c t o r m a y utiliie this r.-vie w i n s u p p o i t of an applicatio n f o r a b u i l d i n g permit n icli the express w n l e r s t a n d i n g t h a t t h i s r e v i e w In tio way reliev e s t h e o w n e r or contra c t o r o r their p'. h.tinial engineer or an.hitec i f o r s o l e responsi b i l i t y fia nil o wiphance wi t h s a i d codes and s t a n d a r d s . n listing an building c o d e or for any respoitsih i l t y for eilcictt i e i r i r s . omissions ot itegligen c e i n t h e s e planI n tether or not noted in :his r e v i e w . Date: Reviewe r : O W kECOMM E N l ) A P P R O V A L 0 RECOM M E N D A F P R O V A I , . AS NOTED DF-52418:A • Al-fib M$'9050UD () Fire uTeALarms Fire Alarm Control Panel with DACT by Honeywell GnrI The Fire-Lite MS-9050UD is a Fire Alarm Control Panel (FACP) and Digital Alarm CommunicatorlTransmitter (DACT) combined into one circuit board. This compact, cost effective, intelligent addressable control panel supports up to 50 addres- sable devices of any type of detectors and modules. With an extensive list of powerful features, the MS-9050UD programs just like Fire-Lite's larger products, yet fits into applications pre- viously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include remote annunciators and reverse polarity/city box transmitter. (4XTMF) Features Listed to UL Standard 864, 9th edition. Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. On-board DACT. 20 software zones. Two independently programmable Style Z (Class A) or Style V (Class B) NAC circuits. Selectable strobe synchronization for System. Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Two programmable relays and one fixed trouble relay. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 500 event capacity. Detector sensitivity test capability (NFPA 72 compliant). Maintenance alert warns when smoke detector dust accu- mulation is excessive. - One person audible or silent walk test with walk-teSt log and printout. - Point trouble identification. Waterflow, (nonsilenceable) selection per monitor point. System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pro-signal per point (NFPA 72 compliant). Up to eight ANN-BUS annunciators. SLC COMMUNICATION LOOP: Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. 50 addressable device capacity (any combination of addressable detectors and modules). Compatible with Fire-Lite's addressable devices (refer to SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS): Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) S - Style Z (Class A) Door Holder Sen,'Ice - Aux Power Source Silence Inhibit and Autosilence timer options. Continuous, March Time, Tempdal or Californi code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 A total power for NACs. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS 1s2. TA. PROGRAMMING AND SOFTWARE:. Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 20 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point DF-52418A • 04/05/07 .-- Page lof 4 User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Trouble (yellow) Alarm Silenced signals (yellow) 16 key alpha-numeric pad. Acknowledge/Step Alarm Silenced Drill (Manual Evacuate) Reset (lamp test) Ordering Options MS-90501.10: Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag con- taining screws, cables, key, etc., manual. DP-51050: Optional dress panel for the MS-9050U0. TR-CE: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houSes two 55 AH batteries CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. BAT Series: Batteries, see data sheet DF-52397. PRTIPK-CABLE: Cable printer/personal computer interface cable. PRN-SF: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trou- ble LED. COMPATIBLE ANNUNCIATORS ANN-SO: Remote LCD annunciator mimics the FACP display ANN-110: Input/Output Module for driving graphic annuncia- tors or relays ANN-S/PG: Serial/Parallel Printer Interlace module for con- necting printer to FACP ADDRESSABLE DEVICES. All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. 80355: Addressable low-profile photoelectric smoke detec- tor. 80355T: Addressable low-profile photoelectric smoke detec- torwith thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (835OLP base included). CLIP MODE ONLY BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. 0350PL: Photoelectric low-flow duct smoke detector. 03SORPL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0 (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-I2LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMBSOO: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9050UD, see the following data sheets (document numbers): AD355 (DF-52386), BG-I2LX (DF- 52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ CRF Series (DF-52130), CP355 (DF-52383), D350PL/D35ORPL (DF-52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 SeneslMDF-300 (DF-.52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), SD355/SD355T (DF-52384): 2) Legacy 300 Series detection devices such as the AD355, CP300ICP350, SD300(T)/S0350(1) and older modules such as the M300, M301, M302, C304, and 8G-IOLX are not compatible with LiteSpeed polling, if the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult fac- tory for further information on previous 300 Series devices Page 2of4—DF-52418A.o4loso7 ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): 47k ohm supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. 3.9k ohm End-of-Line Resistor assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. N-ELR Mounting Plate: Single End-of-Line resistor plate required for use in Canada. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical inter- ference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the following table to determine the specific wiring requirements for the SLC. (Refer to the panel manual for complete details.) CIRCUIT CONNECTIONS WIRE REQUIREMENTS Circuit Type Circuit Wire Type and Recommended Max. Distance Wire Gauge and Compatible Brands Function Umitations Feet (meters) 12 AWG (3.25 mm2): Genesis 4410. Signal 98230, Belden 9583, WPW999 14 AWG (2.00 mm2):Genesis 4408 & 4608 Twisted, shielded pair Signal 98430, Belden 9581, WPW995 40 ohms maximum per 10,000 (3,000 m) 16 AWG (1.30 mm2): Genesis 4406 & 4606 length of Style 6 and 7 8,000 (2,400 m) Signal 98630, Belden 9575, WPW99I loops. 40 ohms per 4,875 (1,450 m) Direct Burial Cable lsotec branch maximum for Style 3,225(980 m) NP7I3II0VNQ-S 4 loops 18 AWG (0.75 mm2): Genesis 4402 & 4602 Connects to Signal 98300, Belden 9574, WPW975 SLC loop (power-limited) Addressable Direct Burial Cable Isotec NP7I4IIOVNQ-S Devices ______________ 12 AWG (3.25 mm2): Belden 5020UL & Twisted, unshielded pair 6020U1, Genesis WG-4315 & WG-4515 40 ohms maximum per 10,000 (3,000 m) 14 AWG (2.00 mm2):Belden 5120UL & length of Style 6 and 7 8.000 (2.400 m) 6120UL, Genesis WG-4313 & WG-4513 loops. 40 ohms per 4,875(1,450 m) 16 AWG (1.30 mm): Belden 5220UL & branch maximum for Style 3,225 (980 m) 6220UL, Genesis WG-4311 & WG-4511 4 loops 18 AWG (0.75 mm2): Belden 5320UL & _____________ 6320UL, Genesis WG-4306 & WG-4506 Untwisted, unshielded 3,000(900 m) 12-18 AWG (325-0.75 mm2) using listed ___ ____ pair8 wire ANN-BUS Connects to Twisted, shielded pair with (ElA-485) annunciator mod- a characteristic imped- 6,000 (1,800 m) 18 AWG (0.75 mm2) (power-limited) ules ance of 120 ohms ElA-232 (power-limited) Connects to remote PC corn- Twisted, shielded pair 50 (15 m) 18 AWG (0.75 mm2) minimum puter _____________ MMF-300 and MMF-301 Initiating Device Maximum loop wire resus- tance is 40 ohms for the 2,500(760 m) 12-18 AWG (3.25-0.75 mm2) (power-limited) Circuit MMF-300 and 20 ohms for the MMF-301 No more than a 2.4 volt MMF-302 (power-limited) Initiating Device Circuit drop allowed at end of cir- cult. Maximum loop wire 2,500(760 m) 12-18 AWG (325-0.75 mm2) resistance is 25 ohms __________itati____ CMF-300 Notification Appli- In alarm, no more than a 1.2 volt drop allowed at Distance limon set by 1.2 volt 12-18 AWG (3.25- 0.75 mm2) (power-limited) ance Circuit end of circuit maximum line drop a) When using untwisted, unshielded wire, full conduit is recommended for optimum EMI/RFi protection. DF-52418:A • 04105107—Page 3 of 4 SYSTEM SPECIFICATIONS L . I System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity............................................50 Programmable software zones.........................................20 Annunciators ......................................................................8 Electrical Specifications AC Power: 120 VAC, 60 Hz, 0.3 A. Battery: Two 12 V 18 AH lead-add batteries. Battery Charger Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connections for two NACs, Style V (Class B) or. Style Z (Class A). Special Application power. Power-limited, supervised cir- cuitry. Maximum signaling current per circuit: 2.5 A. End-of- Line Resistor: 4.7 kohm, /2 watt (PIN 71252 UL listed) for Style V (Class B) NAC: Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65° (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 39F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C160 - 80°F. NFPA Standards The MS-9050UD complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterfiow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterfiow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterfiow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterfiow). - CENTRAL STATION (Automatic, Manual and Waterfiow, and Sprinkler Supervised). Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:210 MEA: 442.06-E LiteSpeedla is a trademark; and FlreLlte® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. _.-z.7r..7... •Vfl. .1 This document is not Intended to be used for Installation purposes. I SO ooi We try to keep our product information up-to-date and accurate. - • • We cannot cover all specific applications or anticipate all requirements. is.. All specifications are subject to change without notice. lustily SYSTEMS For more information, contact Fire-Lille Alarms. Phone: (800) 627-3473. FAX: (877) 69964105. www.firelite.com Page 4 of 4— DF-52418.A • 04105107 Made in the U.S. A. FlreuTeAlarrns PN: 52413:B ECN 07-494 by Honeywell Addressable-'* ire Alarm Control Panel MSm905OUD IMPORTANT! The SLC Manual Document #51309 must be referenced in addition to this manual when installing or servicing the Fire Alarm Control Panel. Document #52413 8129/07 Revision: Power Supply Calculations Calculating the System Current Draw Table 7.3 contains columns for calculating current draws. For each column, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 183. Table 7.3 System Current Draw Calculations Calculation Column I Primary, Non-Fire Alarm Current Device Type (amps) Calculation Column 2 Primary, Fire Alarm Current (amps) Calculation Column 3 Secondary, Non-Fire Alarm Current (amps) Qty X(current draw]= Total Qty X (current draw] = Total Qty X[current draw] Total Main Circuit Board X(0.l20]= 0.120 I X[0.200]= 0.200 I X[0.120]= 0.120 4XTMF [ ] X[0.0051= I ] x[0.0II]1= I I X[0.005]= 4-wire Detector Heads [ ] X[ 2.... [ ] X[ 1= ( ] X[ ] Power Supervision J X(0.025J= Relays [ I X[0.025= [ ] X[0.025]= CP350&CP355 tJ X[0.00030]= maximum alarm draw 0400 for all devices X[O.00030]= IJ X[0.00030J= SD350 & SD355 SD350T & 5D355T - t - T X[0.000301= - I T X[o.0003oj= =5177713355 I X[0.00030]= _7____T_ X[0.00030]= H350 & }1355 X[0.00030]= - 1 X[0.00030]= H350R & H355R - X[0.00030]= - - I X[0.00030J= 11355HT 1 [0.00030J= - -f X[0.00030]= 0350P X[O.00030]= - - XLO.000301= D35ORP L J - X[0.000301= : 3z lo.00030]= B501 BH & B501 BHT4 I I X[0.001]= x[o.00l]= 8224RB Relay Base - X[0.00050J= - - X[0.00050]= B22451 Isolator Base - X[0.00045]= - - X[0.00045] MMF-300 - X[0.00040] - I X[0.00040] MM11-300-10 X[0.003501= - - X[O.00350]= MD11-300 - X[0.000751= - - X[0.00075]= MMF-301 - X[0.000375]= - - X[0.000375J= MMF-302 X[0.00027]= - I - X[0.00027j MMF-302-6 - f X[0.00200]= - X[0.00200J BG-IZLX - X[0.00023]= - X[O.00023 = CMF-300 - X[0.00039]= - CMF-300-6 - I X[0.00225]= - X(O.0002239 X[0.0O5J= CRF-300 T - X[0.00027)= - XLO.00027]= CRF-300-6 - X[0.00145]= - - XFO.001451= 1300 - X[0.00040]= - - X[0.000401= ANN-SO X[0.0370]= I [ ] X[0.04001= - -r_X[0.0I50J= ANN-I/O - X[0.0350]= [ I XLO.200]= - - X[O.0350]= ANN-I/O LEDs X[0.0001= [ ] X[0.010]= I- -J X[0.000]= ANN-S/PG j X[0.0450]= I NAC#1 NAC#2 Sum each columns for totals Primary Non-Alarm = I I XLO.0450]= I- [ ] X[ 1= [ J XL I Primary Alarm = - J X[0.0450]= Secondary Non-Alarm = Table Footnote If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. Refer to the Device Compatibility Document for standby current. Must use compatible listed Power Supervision Relay. Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC source. Current limitation of Terminal TBI circuits is 2.5 amps total max. Total current draw listed above cannot exceed 2.7 amps. 182 MS-9050UD PN52413:11 8/29/07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0210 Page 1 of I CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC., ONE-FIRE-LITE PLACE, NORTHFORD, CT C6410 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Model MS-9050U0 addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise),automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VOC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds 07-07-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed 11 j\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an , endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation :nstructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division df-52417:b • B-90 ANN-80 ri ureALarms 80-Character LCD b" Honeywell Serial Annunciator Annunciators The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-805 may be connected to the ANN-Bus of each FACP No programming is required, which saves time during system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACR ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Aesthetically pleasing design constructed of durable Lexan. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4' square electrical box. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-80s can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 490C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved (ANN-80) CSFM: 7120-0075:211 MEA: 442-06-E (ANN-80) The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. dl -5241 7:b • 05/30/08 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. * 6,000 ft. *6000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ff. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and power-limited. ORDERING OPTIONS: ANN-80: Red, 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. TBI ANN-BUS Device - 12345678 FACP Wiring to ANN-BUS Device FireLite® Alarms is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 0-M-ma 1410 13= We cannot cover all specific applications or anticipate all requirements. llMMIM IMW1IFAC1IAING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-52417:b • 05/30/08 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of I CATEGORY: 7120 -- ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC., ONE-FIRE-LITE PLACE, NORTHFORD, CT 06410 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 Email: Brian.ReynoIds2HoneywelI.com DESIGN: Model ANN-80 and *ANN..80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. NOTE: *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I Featu res Absorbent Glass Mat (AGM) technology for superior performance i— _75.90A Of MOOEL '° Fl - Quick disconnect tabs, 0.187"x 0.032"- Mate with AMP. INC. FASTON "187" series -OR- F2 Quick disconnect tabs, 0.250" x 0.032" -MatewithAMP. INC FASTON "250" series I -r n A n SDN7HT H MaDEl. FS-127 Fl == I 1 I L 5.95(151) W. 2.56(65) H: 3.70(94) HI: 3.86(98) Tolerances are +1-0.04 in. (1- 1mm) and +/- 0.08 In. (+/-2mm) for height dimensions. NI data subject to change without notice. Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 Performance Specifications NominalVoltage Nominal Capacity 20-hr. (350mA to 10.50 volts) ........................................................7.00 AH 10-hr. (650mA to 10.50 volts) .......................................................6.50 AH 5-hr. (1.2A to 10.20 volts) ............................................................6.00 AH 1-hr. (4.5A to 9.00 volts) ..............................................................4.50 AH 15-mm. (14A to 9.00 volts).................................................................3.50 AH Approximate Weight ...........................................................4.80 lbs. (2.18 kg) Energy DensIty (20-hr. rate) ................................t49 W-h/in3 (90.95 W-h/1) Specific Energy (20-hr. rate) ..............................17.50 W-h/lb (38.58 W-h/kg) Internal Resistance (approx.) ......................................................23 milliohms Max Discharge Current (7 Mm.) ...............................................21.0 amperes Max Short-Duration Discharge Currant (10 Sec.) .................. 70.0 amperes Shelf We (% of nominal capacity at 68°F (200C)) IMonth .....................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Rang. Charge .. ........................................................... -4°F (-20°C) to 122°F (50°C) Discharge ...................................... . .................. -40°F(-40°C)to 140°F (60°C) Case...................................................................................................... Ass Plastic Power-Sonic Chargers ................................................ PSC-12800A, 12800AC Fl F2 1-3.4-4 IIEIiI636 1-6.25-I ______ mO O8 Shelf Life & Storage 100 - 920 6c -(4~lFld 40° C1 atty.00nt o 40 - - (104°F). —(88°F) - ..(68°F)f_ Jesruct) 0 0 2 4 8 8 10 12 14 16 18 20 Standing Period (Months) Discharge Characteristics 14.0 Ill I I Ill I I Ambient Temperature 20°C (68°F) 1.4 .0 8.0 14 Discharge Time vs. Discharge Current 0.35 0,70 1.4 3.5 7.0 14 Discharge Current (A) Cycle Applications: LimIt Initial current to 2.IA. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 70mA. Battery Is fully charged under these conditions, and charger should be disconnected or switched to 'float" voltage. "Float" or "5tnd4y" SsMoes Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Notes Due to the self-discharge characteristics of this type of battery, it Is Imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfatlon. l.& £. IL LVO1 L At UUIV LV ap V i n mm h 101 Discharge Time Life Characteristics in Stand-By Use 00 - - - - Ambient Tempemture 20°C (65°F) 8C-- - -. - 60-- 40 Float 2.25-2.30 Charging VICelI Voltage -- - - - 20 -- n -- -- -- - - 0 1 2 3 4 Years Life Characteristics in Cyclic Use i±:-. D1100% DWW bspth 30% 1. Discharge Current 0.2C (Final Voltage 11.7=911) -2. Charge Current: CAC I 3. Ambient Temperature: 20°C to 25°C (68°F to 77°F) I I I 0 200 400 600 800 1000 1200 Number of Cycles 120 100 .80 60 40 20 A J 20 15 10 . T 1 0 30 10 Power-Sonic offers a wide range of chargers suitable for batteries up to IOOAH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for °C-Series downloads, such as product catalogs, material safety data sheets (MSDS), ISO Switch Mode Chargers° and "Transformer Type A and F Series". Please contact our certification, etc.. Technical department for advice If you have difficulty in locating suitable models. DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAl. 5*1.15 Tel: +1.819.661-2020 Tel: +1-619-681-2030 Tel: +1-619-661.2020 Tel: +1650-364-5001 Fax: +1-619.661.3650 Fax: +1-619-661-3648 Fax: +1-619-661-3648 Fax: +1-650-369-3662 national-salesOpower-sonic.com customer-serviceOpower-sonic.com support@power-sonic.com battery@power-sonlc.com BG-12LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACP5). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for elsy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-i 0 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4(10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanicsms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. Specifications Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 pA. Ambient Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 930/6 ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F) For use indoors in a dry location Installation The BG-1 2LX will mount semi-flush into a single-gang, double- gang, or standard 4' (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). DF-52013:A. E-100 (a FireuTeALarms by Honeywell ii Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to thepanel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600, 1 - 99 and MS-9200UDLS, 1 50 for MS-9050U0). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. DF-52O13:A.O252OO8—Page 1 o12 Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-I2LX: Dual-action addressable pull station. Includes key locking feature. SO-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S71 1 MEA: 67-02-E CSFM: 7150-0075:184 FM Approved A___ Detail of — I BREAKAWAY TAB* 15 0 EADDRESS 0 2 i 1*2 12ITIfl\3 11IfU)4 LOOP 10 -••- 5 I A L.QJ A Back Of station without door Terminal Connections: 1 SLC (-); 2 SLC (+) I ROTARY DECIMAL LED Remove tab to select addresses above 99. Cover open toshow easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Flre.Llte is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Im Iso9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IIALIT SYSTEMS Made in the U.S. A. For more information, contact FlreLJte Alarms. Phone: (800) 627-3473, FAX: (877) 69964105. www.firelite.com Page 2 of 2— DF.52013:A • 02/05/2008 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of I CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC., ONE-FIRE-LITE PLACE, NORTHFORD, CT 06410 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 Email: Brian.Reynolds2HoneyweII.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-I2LW, BG-I2WP, BG-I2LWP, BG-12L, BG-I2LX, BG-I2LA, BG-I2PS, BG-I2LSP, BG-I2SP, BG-I2LR, BG-I2LRA, BG-I2LAO, BG-I2LAOB, BG-12-LO, BG-I2LOB, BG-12LPS, BG-12LPSP, BG-I2SL, UT-PSI and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division FlreuTe iarms www.flrellte.com GENERAL The Fire-Lite Alarms 5D355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state-of- the-art photoelectric sensing chamber with communica- tions to provide open area protection and are used exclu- sively with Fire-Lite's MS-9200, MS-9200U0, and MS-9600 Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving pre- cious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor. indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z). - FEATURES SLC loop: Two-wire loop connection. Unit uses base for wiring, detector head plugs-in. Addressing: Addressable by device. Direct Decade 01 — 99 (MS-9200, MS-9200UD) and 01 — 159 (MS-9600) entry of address. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-In tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 1.500 feet-per-minute (7.6 rn/sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold !evil. Visible LED "blinks" when the unit is addressed (com- municating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included). July 14, 2004 DF-52384 • E-160 SD355(A)/ 5D355T(A) Addressable Photoelectric Smoke Detectors Section: Addressable Devices California State Fire Marshal 4!!!) A 7272..0075:194 LISTED S1059 MEA APPROVED rr. .. \ (\. • Z- 534ho1.g - SD355 with "-- B350LP basl_7 T - SD355T with B35OLP base Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current Options: Remote LED output connection (P/N RA400Z) APPLICATIONS Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. ionization detec- tors are often bettei than photoelectric detectors at sens- ing fast, flaming fires. Flre'UteS Alarms Is a Honeywell company. This document Is not Intended to be used for Installation purposes. We try to keep our product 130-9001 Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact FiresLite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. fUl I MNl1IlFI Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-62384 • 07/14/04 — Page 1 of 2 CONSTRUCTION These detectors are constructed of off-white LEXAN®. SD355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appear- ance. LEXANS is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION S0350(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the Inherent supervision provided by the SLC loop, end-of-ilne resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class B) wiring only. OPERATION Each 5D355(T) uses one of 99 possible addresses on the MS-9200 and MS-9200UD Signaling Line Circuit (SLC), or up to 318 (159 on each loop) on the MS-9600 SLC. It re- sponds to regular polls from the system and reports its type and status. The 5D355(T) addressable photoelectric sensor's unique unlpolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 1,500 feet-per-minute (7.6 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the SD355(T)is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have their sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Main- tenance) when installed/connected to an MS-9200, MS- 9200UD, or MS-9600 addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS- 9200, MS-9200UD, or MS-9600 for record keeping. SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 isA @ 24 VDC. LED current: 6.5 mA Q 24 VDC (latched "ON'). Air velocity: 1,500 ft/mm. (7.6 rn/sec.) maximum. Diameter: 6.1" (15.5 cm) installed in B350LP base. Height: 2.1" (5.33 cm) installed in 835OLP base. Weight: 3.6 02. (102 g). Operating temperature range: for SD365: 0°C to 49°C (32°F to 120°F) SD350; for S0355T: 0°C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F -120°F). Relative humidity: 10% - 93%, non-condensing. Pane 2 of 2 - OF-52384 07/14/04 PRODUCT LINE INFORMATION NOTE: "A" suffix Indicates ULC-Listed model. 5D355 Addressable photoelectric detector (B35OLP base included). 8D355A Same as SD355 with ULC Listing (B35OLPA base included). SD355T Same as SD355 but with thermal element (8350LP base included). SD365TA Same as SD355T with ULC Listing (835OLPA base included). RA400Z(A) Remote LED. Mounts to a single-gang box. 835OLP(A) Plug-in detector base (included). Dimen- sIons: 6.? (15.5 cm). Mounting: 4.0(10.16 cm) square box with or without plastic ring, 4.0" (10.16 cm) octagonal box, 3.5"(8.89 cm) octagonal box, or single-gang box. All mount- ing boxes have a minimum depth of 1.5" (3.81 cm). B224R0(A) Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plastic ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B22481(A) Intelligent isolator base, isolator SLC from shorts on the loop. B50IBH(A) Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plastic ring. Mounting box has a minimum depth of 1.6'(3.81 cm). B50IBHT(A) Same as B50IBBH(A), but includes tempo- ral sounder. Accessories: RMOOZ(A) Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. For use with B501(A) and 8350LP(A) bases only. SMK400. Surface mounting kit provides for entry of surface wiring conduit. For use with 8501(A) base only. RMK400 Recessed mounting kit. For use with 8501(A) base only. M02-04-01 Test magnet XR-2 Detector removal tool. Allows installation and/ or removal of detector heads from bases in high ceiling applications. XP-4 Extension pole for XR-2. Comas in three 5-ft. (1.524 m) sections. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION M . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of I CATEGORY: 7272 -- PHOTOELECTRIC SMOKE DETECTOR LISTEE: FIRE-LITE ALARMS INC., ONE-FIRE-LITE PLACE, NORTHFORD, CT 06410 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 Email: Brian.ReynoIds2Honeywell.com DESIGN: Models 50350, SD350T, SD355, S0355R*, SD355T and AD355 photoelectric type smoke detectors. Model SD350T and 5D355T has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models S0355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing 0355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. Rev. 01-11-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational + requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0192 Page 1 of I CATEGORY: 7300 - MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: FIRE-LITE ALARMS INC., ONE-FIRE-LITE PLACE, NORTHFORD, CT 06410 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 Email: Brian.ReynoIds2HoneyweII.com DESIGN: Model B350LP detector base. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as a detector base for use with listee's separately listed Models CP350, SD350, SD350T, H350 and H350R detectors. NOTE: *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ' the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO , Program Coordinator Fire Engineering Division DF-52121:C • E-325 MMF-300(A) Series, MDF-300(A) (a FareLrreALarms I-fl,U II Addressable Monitor Modules IJY IJUl IVVIl Addressable Devices General Four different monitor modules are available for Fire'Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D used to super- vise a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTm is a communication protocol developed by Fire'Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. designs. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit lWPfl'i f MMF-300(A) (Type H) may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). Nominal opertjg ,9ttge: 15 to 32 VDC. Maximum cu= ating : 5.0 mA (LED on). Average ope 4nt: 350 pA (LED flashing), 1 corn- munictioi' every 5 seconds47k EOL. IDC wiring reslstanbe 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4 (10.16 Cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DF-52121:C.1O/0612010— Page lof4 MMF.301 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems 1415 0 1 ADDRESS 13 12 3 11 ell TENS ONES OIILU C) -j J LU - LO >-I The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, watertlow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF.302(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF402(A) OPERA TION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 4— DF-52121:C • 10/06/2010 MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cults ONLY. Style 0 (Class A) I0C circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (00 to 490C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Product Line Information NOTE: "A"suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly toa standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM Approved CSFM: 7300-0075:0185 MEA: 72-01-E DF-52121:C • 10/06/2010 - Page 3 of 4 Fire-Lite® and LiteSpeed® are registered trademarks and FireWatchiM is a trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. _________ d • We cannot cover all specific applications or anticipate all requirements. EE=lUMlNE $MANIM1IRIM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121:C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of I CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: FIRE-LITE ALARMS INC., ONE-FIRE-LITE PLACE, NORTHFORD, CT 06410 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Models MDF-300, MMF-301 MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational '7 requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 'F SYSTEM SENSOR 4-Wire Photoelectric Duct Smoke Detector The lnnovairFlex'° Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. innovczifr" The InnovairF!ex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The InnovairFiex housing provides ample wiring space, a Y4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The lnnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFiex product line is compatible with all previous Innovair Agency Listings models, including remote test accessories. WARNING: Duct smoke detectors are NOT a substitute for open MSFM area smoke detectors; NOT a substitute for early warning detection; LISTED APPROVED tT1 approved NOT a replacement for a building's regular fire detection system. 5911 3029700 3242.1653207 2202 Refer to NFPA 72 and 90A for additional information. Features Photoelectric, integrated low-flow technology Air velocity rating from 100 fit/min to 4,000 ft/mm (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 'A-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories lnnovairFlex' Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex D4120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the SSK45 1 Multi-Signaling Accessory or the RTS451 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: (Rectangular Dimensions) 14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (636 cm) Depth (Square Dimensions) 7.75 in (19.7cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature Range: D4120 & 045: -4° to 158°F (-20° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Storage Temperature Range: 04120 & D4S: -22° to 158°F (-30° to 70°C); 04P 120: -40° to 158°F (-40° 1070°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 2032 m/sec) Electrical Ratings Power supply voltage: 20-29VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 p max. 270 pF max. N/A Reset voltage: 3.OVDC mm. 2.OVACmin. 1OVAC mm. Reset time: (with RTS4S1) .03 to 03 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. - -- Power uptime: 35 sec. max. 35 sec. max. 35 sec. max. Alarm response time: 15 sec. 15 sec. 15 sec. SensitivityTest: See detector label See detector label See detector label Current Requirements; (Using No Accessories) Max. standby current; 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Contact Ratings Alarm initiation contacts: (SPST) 2.OA @ 30VDC (resistive) Alarm auxiliary contacts: (DPDT) 10A @30 VDC (resistive); 10A @ 250 VAC (resistive); 1h HP @ 240 VAC ; ¼ HP @12OVAC Note Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPOT) 2.OA @30 VDC (resistive); 2.OA @ 125 VAC (resistive) Accessory Current Loads at 24 VDC Device Standby Trouble Alarm APA1S1/APA451 12.5 mA n/a 30mAMax. MHR/MHW 0 mA n/a 29 mA Max. RA100Z OmA rila 12mAMax. RTS151/RTS151KEY 0 mA/12 mA n/a 12 mA Max. RTS2/RTS2-A0S 3.0mA max 16 mA Max with strobe: 55 mA max; without strobe 30 mA max Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output and 50 mA or less at the Alarm output Installing the InnovairFIex Sampling Tube The lnnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). OS-O4l92 Wiring for 4-wire Duct Smoke Detector and Accessories I POWER INPUTS (NOTE 1) I I r4'.i r 910 I OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB I I "Cl -r-11 " "..I. N -1 SUPERVISORY CONTACTS ' SUPERVISORY CONTACTS I (NOTE 3) I I (NOTE 3) - POWER INPUTS (NOTE - I 4VACIDç 120 ( $ VVAC1 OR AUXILIARY CONTACTS FOR FAN SHUTDOWN, ETC. (NOTE 2) AUXA AUXB EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or 24VAC 50-60Hz. 120VAC Power Inputs accept only 120VAC 50-60Hz. Connect power source to appropriate terminals of each detector. See specifications for additional power supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. Please refer to the corresponding installation manual for accessory wiring diagrams. Important Notes on 2:1 Sensor-to-Power Capability 2:1 sensor-to-power capability is not available for all lnnovairFlex models. The feature is only available on the 041204-wire conventional models. 2:1 sensor-to-power capability can be enabled using one 04120 and one D4S, or two D4S and one D4P120. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit ito the lNT+ terminal on unit 2 and so on. Similarly, connect the INT/AUX— terminal on unit ito the INT/AUX- terminal on unit 2 and soon. Up to 5004120 units. 50 04P120 units, or 50 units of combination may be interconnected. Up to 10 OH 100ACDC units may be interconnected. Please note that each of the 9 DHi OOACDC units interconnected may be replaced by three 04P1 20 units. Therefore, when using the interconnect feature a single DH 100ACDC can drive either 9 OH lODACOCs or 27 D4120 units. NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. A05-N19-W2 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. RTS151 UL S4011 RTS151KEY UL 52522 APA151 UL S4011 RA100Z UL 52522 MHWUL 54011 MHRULS4O11 AOS Information D4120 4-wire photoelectric low-flow duct smoke detector Accessories D4S 4-wire photoelectric sensor component only D4P120 4-wire photoelectric power board component only, 24VAC/DC, 120 VAC 2D51 4-wire conventional photoelectric sensor head DST1 Metal sampling tube duct width up to tft (03m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (03 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST5 Metal sampling tube duct widths 4 ft to 8 f (1.2 to 2.4 m) DST1 0 Metal sampling tube duct widths 8ftto 12 ft (2.4 to 3.7 m) APA1 51 Remote annunciator with piezo alarm DH400 OE-1 Weatherproof enclosure ETX Metal exhaust tube duct width ift (0.3m) M02-04-00 Test magnet MHR Mini Horn, Red MHW Mini Horn, White P48-21-00 End cap for metal sampling tubes RA100Z Remote annunciator alarm LED RTSIS1 Remote test station RTS151 KEY Remote test station with key lock RTS2 - AOS Multi-signaling accessory S'fr'TEA,7 3825 Ohio Avenue. St. Charles, IL 60174 02010 SytenSnso. Pcducnpecl&auonssuenrochangewthouInonce.Asnsygemserna,comfo, SENSOR" Phone: 800-SENSOR2 Fax: 630-377-6495 AGO-Ol 19002 -2110. 0230S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1653:0207 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave,, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: Models D4120, RD4120*, P270-3000PL, TD41203, TD41204, LD4S, LD4I20X, LD4I20H, D4S, D4P120, 1-D4P120X, LD4P12OH, TD4C, PD4120, Y04120, and YD4P120* four-wire conventional photoelectric duct smokedetectors and subassemblies. Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 21351 detector head (CSFM Listing No. 7272-1653:203). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC, 120 VAC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 02-01-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division f~ SYSTEM $ SENSOR Duct Smoke Detector Accessories Expand the versatility of the InnovairFIef line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 MHR MHW RA1 OOZ/RA1 OOZA RTS1 51 RTS1 51 KEY RTS2 AOS RTS2-AOS Piezo Annunciator Mini-Horn, Red Mini-Horn, White Remote Annunciator Remote Test Station Remote Test Station with Key Multi-Signaling Accessory Add-On Strobe Multi-Signaling Accessory Agency Listings Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA1S1 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlerf Advance mini-horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS151 and RTS1S1KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS1 51 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectOrs. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. USTED AOS MHRULS4O11 cOIOStemStnuør Podct upeocaI !cltodgethu1 emunsucmfou otth,idat.het. AOS.0423.001.2/I3.2309 3825 Ohio Avenue. St. Charles, IL 60174 SENSOR' Phone: 800-SEN5OR2 ° Fax: 630-377-6495 Specifications, Duct Smoke Detector Accessories Voltage Regulated 24VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non-càndensing Wire Gauge 12to18AWG Dimensions 4.6H x 2.9Wc .45D MHR/MHWSpectrAIerf Advance Voltage Mini-Horns Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync-Circuit Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 17.5 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz - Wire Gauge 12to18AWG Dimensions Voltage Range 4.6 H x 2.9W x 0.45 D Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 12 mA Dimensions 4.6Hx2.8Wx1.3D Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 1OVA @32 VOC Reset Switch 1OVA @32 VDC Alarm Responselime 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions 4.8'H x 2.90W x 1.4 D Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. -Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14t0 18AWG Dimensions RTS2 and RTS2-AOS Multi Voltage 4.6 H x 2.75W x 1.8D -signaling Accessory 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8-Wx5.3Hx 1.6D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. —I flu anJ., JL jzjzz CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of I CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave,, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.Iinhartsystemsensor.com DESIGN: Models RTS1 51, RTS1 51 KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Save up to 48% in current .draw* -Pp to 9 models now in I appliance - Save up to 14% cost of installation** 10 Sleek Modern Aesthetics W. Finger Slide Switches Voltage Test Points Multiple Voltages I3 Audible Settings 90, 95, 99 dB g 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 )Universal Mounting Base CO Ceiling and Wail Mounts to 5 Backbox Types QCED-IM Finally, Design and Safety Meet... Description: The Wheelock5 ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederrM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatlblhty and Requirements - Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock* Patented Sync Protocol• - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS Input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range * Compared to competitive models *** Patented Compared to previous models NOTE All CAUTIONS and WARNINGS are identified by the symbol A.. All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND!OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their 'Regulated Voltage Range'. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for Indoor use with a temperature range of 32'F to 120'F (0C to 49CC) and maximum humidity of 93% (± 20A) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC uJuMaxL Current* izj:r I ____ 24VDC I 12VDC Model 777 45; 75 110 Lii 135 150 177 185 _____ HS 8.0-33.0 00.082 .095 0.102 0.148 0.176 0.197 0.242 0.28210.12510.159 HSC 1 8.0-33.0 10.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 I 24 VDC ' 12VDC Model Regulated Voltage Range VDC 15 15/75 30[60} 95 110 115 135 150 177 185 15 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 I 0.186 0.230 0.272I0.122 0.153 HSC 8.0-33.0 0.073 0.08710.12810.13910.163 -- 0.186 0.230 0.272 0.122 I 24 VDC ' 12 VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 I 95 I 110 115 1135 T150T177T.5 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 _____ 0.184 0.226 0.267 0.120 0.148 HSC 1 8.0-33.0 1 0.065 0.084 0.120 0.1360.157 0i841I022610 267 0.120 Horn Ratings per UL 464 Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For itrobes the UL max current is usually at the 'minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiRered ratings, see installation instructions. Specification & Ordering Information Model Strobe Sync WI SM, DSM or 12/24 VDC Mounting S IS- Candela P5-6 & PS-8 Options UMB HSR 1511575130175195111011351185 X X • HSW 1511575/30175/95111011351185 X X UMB** HSRC 15130160/75195111511501177 X X UMB** • HSWC 15130160175/95/11511501177 X X UMB** STIR 15/1575/30/75/95/110/135/185 15/1575/30/75195111011351185 X X UMB** STW 1511575130/75/9511101135/185 X X UMB** STRC 15130/60/75/9511151150/177 X X UMB** * STWC 15130160/75195111511501177 X X UMB** UMB** HNR X X HNW • X X UMB** HNRC • ion X X UMB** HNWC X X UMB 92 VDC models feature 15 & 15/75 settings **UMB = Universal Mounting Base Notification Wheelock 1DcJ Architects and Engineers Specifications The notification appliances shall be Wheelock® ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 11109 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Lyn Sorrentino (732) 962-7832 Fax (732) 962-7856 Email: Iyn.sorrentino©cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn-strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a'-NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15,15/75, 30, 75, 95, 110, 135& 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount. only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed j\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division IT L Wy ?UOc*f FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: WAy TE £ Address: 596.3 I-A PhACE C7 IP 200 6WXeAb, Representative of protected property (name/phone): G4c"c fl/ Authority having jurisdiction: dAA4.5,8Ab /A4 47 Address/telephone number: Organization name /phone Representative name /phone Installer CA1/04014 C 1#,47W'4t iCC.LITY 04Wô /44L ('7.5c' •79 Supplier _t1tI!t#77 2 03. '?4'. 7/(/ ZR. 96Vi Service organization e C Location of record (as-built) drawings: 71 9/ ,0AJ0L,eos4 '4(14 -70'0 S't) 6.4 l. #2.3 Location of operation and maintenance manuals: 69C3 1-4 /44ci. C 7. CA ?L.cEA0 -C,4. 92 c'oB Location of test reports: .544-1 A contract for test and insp9ction in accordance with NFPA standard(s) Contract No(s): A' Effective date: iV/4 Expiration date: _______________ System Software Operating system (executive) software revision Site-specific software revision date: Ar Revision completed by: (name) 1. Type(s) of System or Service I (s): B (firm) NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8 - Remote Station Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8— Proprietary Telephone numbers of the organization receiving alarm: Alarm: Sunervisnrv: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: V NFPA 72, Chaptei Prime contractor: Central station lo (NFPA 72, 1 of 4) Means of transmission of signals from the protected premises to the central station,: McCulloh Multiplex One-way radio Digital alarm communicator Two-way radio _______ Others Means of transmission of alarms to the public fire service communications center: System location: _____NFPA 72, Chapter 9—Auxiliary Indicate type of connection: _______ Local energy Location of telephone number for receipt of signals: - 2. Record of System Installation Shunt ______ Parallel telephone (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standar1s as shown below, was inspected by l)4 Vi Iv A'á2tL. on ' ,includes the devices shown in 5 and 6, and has been in service since _7-5 ______________ __1YFPA 72, Chapters &Xi 3 J5 6 8 9 10 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other Signed: Date: 716-//1 Organization: 6 4L/A C e011 LiMTY 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features and functions of this system were tested by DA V date .7 and found to be operating properly in accordance with the requirements of: _LILFPA 72, Chapters j.-& 3 .'5 6 & 8 9 10 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other Signed: Date: Organization: C-AL (1. L-ØM,4 - 5aC VaQi"/ Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity:.... I Style: 4L.___________ Class: 6' (NFPA 72, 2 of 4) 5. Alarm-Initiating Devices and Circuits Quantity and class of initiating device circ it, (see NFPA 72, Table 6.5): Quantity: Style:_ Class: MANUAL (a) Manual 'stations Noncoded Transmitters_________ Coded _e Addressable (b) Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete Partial Selective. Nonrequired Smoke detectors________ Ion Photo / Addressable Duct detectors Ion Photo /0 Addressable Heat detectors FT RR FT/RR __________ RC Addressable Sprinkler waterflow indicators: Transmitters_. Noncoded________ Coded ________ Addressable________ The alarm verification feature is disabled or enabled _______ ,changed from seconds to _______ seconds. Other (list): 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR Coded stations Noncoded stations (c)L. Compulsory guard's tour system comprised of ____________ transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. SPRINKLER SYSTEM Check if provided (a)A//4 Valve supervisory switches (b>?A Building temperature points (c) Site water temperature points (d)Ak. Site water supply level points Electric tire pump: (e)/ Fire pump power Fire pump running (g)MA- Phase reversal Engine-driven fire pump: (h)/4 Selector in auto position (i) Engine or control panel trouble Ci) iwk-.. Fire pump running ENGINE-DRIVEN GENERATOR: (a)jLL Selector in auto position Control panel trouble (c) P1 Transfer switches (d) ' Engine running Other supervisory function(s) (specify): (NFPA 72, 3 of 4) 7. Annunciator(s) Number: / Type: AA/4J 8o Location: peOc- oy 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: ______________________ Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: Style: ____________ Class: Types and quantities of notification appliances installed: Bells ________________________ With Visible Speakers With Visible (C) Horns With Visible / Chimes With Visible Other: With Visible Visible appliances without audible: 9. System Power Supplies Fire Alarm Control Panel: Nominal voltae: /2 " 0 Overcurrent protection: Type: L1A'4 4 7&. Location: i?P. C/IZ # Secondary (standby): Storage battery:/2v(x .i) Amp-hour rating: 74.k. Calculated capacity to drive system, in hours: Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency system used as backup to primary power supply: Emergency system described in NFPA 70, Article 700: Current rating: / _ I_- Current rating: / 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: V .5. TE0/'/1'-14J (title) (date) otractor/sup (signe 9 * P, ~~ 6,Z- t an /A4/ 7.7-4f-11 (signed) for alarm service company (title) (date) (signed) for central station (title) (date) of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): having jurisdiction (NFPA 72,40f4)