HomeMy WebLinkAbout2470 FARADAY AVE; ; AS090097; Permit5/23/24,1:20 PM AS090097 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2470 FARADAY AV Permit Type: SPRINK Parcel No: 2090402800 Lot #: 0 Reference No.: Permit No: AS090097 Status: ISSUED Applied 8/19/2009 Approved: Issued: PC #: Inspector: Project Title: BECKMAN COULTERBSW T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: HAGAMAN FAMILY SURVIVORS 1990 TRUST 11-07-90 5320 SUNNY CREEK RD CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 tqco /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series DS-1 - 56 K-factor Dry Type Sprinklers Standard Response, Standard Coverage General Description The Tycoa Series DS-1, 5.6 K-factor, Standard Response, Standard Cover- age, Dry Type Sprinklers are decorative 5 mm glass bulb automatic sprinklers designed for the following typical uses: where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures (e.g. sprinkler drops from unheated portions of buildings) where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated area of a building) where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS-1 Di',' Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of spnnkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the perfonnance of these devices. The owner is responsible for maintain- ing their fire protection system and do- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers TY3255 - (Pendent) TY3155 - (Upright) TY3355 - (Horizontal Sidewall) Technical Data Approvals UL and C-UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/psi1'2 (80,6 LPM/bar19 Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated Physical Characteristics Inlet.....................Copper Plug ....................Copper Yoke ..............Stainless Steel Casing . . . . Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ..........Stainless Steel Bulb ......................Glass Compression Screw ........Bronze Deflector.................Bronze Frame...................Bronze Guide Tube.........Stainless Steel Water Tube.........Stainless Steel Spring.............Stainless Steel Sealing Assembly ................ Beryllium Nickel w/Teflon* Escutcheon ..........Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 Page 1 of 8 JANUARY, 2008 TFP500 Page 2 of 8 TFP500 SPRINKLER FINISH TY3255 Pendent TY3255 Pendent TY3355 Hor. SIdewall wl Standard wi Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector-to-Colling (Ref. Fig. 3) wl Deep Escutcheon distance of wl Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon W/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) wl Std. Escutcheon (Ref. Fig. 9) wl Deep Escutcheon TY3155 Upright (Ref. Fig. 10) w/o Escutcheon w/o Escutcheon (Ref. Fig- 8) (Ref. Fig. 11) Temperature Bulb Color Natural Chrome White Natural Chrome White Natural Chrome White Rating Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F/57°C Orange 1.2.3.4 1,2.4 1,2,3.4 1.2,4 1.; 2.; 3", 4 1*. 2*, 4 1551F/680C Red 1.2.3.4 1.2,4 1.2,3.4 1.2.4 i.; 2.; 3". 4 1*, 2*. 4 175"F/79"C Yellow 1.2,3.4 1.2,4 1.2.3.4 1.2.4 i.; 2.; 3—,4 1*, 2*, 4 200"F/930C Green 1,2.3,4 1,2.4 1.2,3.4 1.2.4 1.; 2.; 3"'. 4 1*. 2*. 4 286°F/1410C Blue N/A 1.2.3.4 1,2.4 1.; 2',3*'. 4 1", 2*. 4 360"F/182"C Mauve N/A 1,2,3.4 1.2.4 i.; 2.; 4 1", 2*. 4 Notes: Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only Light Hazard Occupancies Only. N/A- Not Available. TABLE A SERIES DS-I, STANDARD RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET GASKETED SPRING PLATE SEAL - - YOKE SPRING _- CASING U U WATER TUBE - INSERT GUIDE TUBE BULB SEAT 7 FRAME 5 m BULB VENT HOLE - COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-I, STANDARD RESPONSE DRY TYPE SPRINKLERS ASSEMBLY WRENCH RECESS WRENCH FLAT PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W-TYPE 7 SPRINKLER WRENCH TFP500 Page 3 of 8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r --, -- FACEOF SPRINKLER FITTING ATI1NG -J ORDER LENGTHS: 3-1/2' to 48' 8,9 to 1219,2 mm) IN 1/4"(6.4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING rJA (34,9±; mm) 1I0m!!J FIGURE 3 TY3255 PENDENT wi STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRIFERIASEC11ON) r I---' -------- FACE OF SPRINKLER FITTING '---r ij ORDER LENGTHS: 3-1/2" to 48" (88.9 to 1219.2 mm) 11 IN 1/4(8.4mm) 3" DIA. INCREMENTS (76,2 mm) FACE OF CEILING 1-318 *1/8" 3-5/8" DIA. (34,9 ± 3,2 mm) (92,1 mm) FIGURE 4 TY3255 PENDENT wi WIDE FLANGE RECESSED ESCUTCHEON SPRINKLER FITTING (PH TO DESIGN CRITERIA SECTION) r ------------ FACE OF , H SPRINKLER i_: FITTING J ORDER LENGTHS: I 2-1/2" to 48" 1-3/4' DIA. (63,5'to 1219,2 mm) (44.5 mm) IN 1/4" (6.4 mm) INCREMENTS FACE OF CEILING I - tc (76,2 mm) FIGURE 5 TY3255 PENDENT wi STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r-- I-------I I FACE OF SPRINKLER L.44 I I-i) FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2" to 46" (88.9 mm) (12jto1168,4mm) 221/2- Dk INCREMENTS l I FACE OF CEILING 4-1/4'±1/8 (108,0:t 3,2 mm) FIGURE 6 TY3255 PENDENT wi DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER L] FITTING I' ORDER LENGTHS: 5 to 48' (127.0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4 (44,5 mm) DEFLECTOR TO CEILING FIGURE 7 TY3255 PENDENT wlo ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5 t048" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3155 UPRIGHT w/o ESCUTCHEON ORDER LENGTHS: FACE OF 1/2' to 45-314'(12,7 to 1162,1 mm) MOUNTING IN 1/4'(6.4 mm) INCREMENTS SURFACE 4-13/16'* 1/8' '1 (122,2±3,2mm) 21/2'DIA. I FACE OF r:Z(63.5 mm SPRINKLER FITTING 3-1/2" DIAL 1 (88,9 mm) SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16' CRITERIA SECTION) OF WATERWAY (7.9 mm) FIGURE 10 TY3355 HORIZONTAL SIDEWALL wi DEEP ESCUTCHEON Page 4 of 8 ORDER LENGTHS: 2-1/2' to 48' (63,5 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS 4±1/8 1 (101,6*3,2mm) FACE OF FACE OF I 1-3/4' DIA. -T- - SPRINKLER MOUNTING -i (44,5 mm) J_L FITTING SURFACE LIL__1J / T-J (76,2 mm) SPRINKLER FITTING C) (REFER TO DESIGN CENTERLINE 5116' CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3355 HORIZONTAL SIDEWALL wi STANDARD ESCUTCHEON TFPSOO Operation When the Series DS-1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref; Figure 1) in the Inlet of the Sprinkler. The glass Bulb con- tains a fluid that expands when ex- posed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is. released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This ac- tion simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. Design Criteria The Tyco9 Series DS-1 Sprinklers are intended for use in fire sprinkler sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Usting is based on NFPA 13 requirements). The 1 inch NPT Series DS-1 Sprin- klers are to be installed in the 1 inch NPT outlet or run of malleable or duc- tile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the dimension- al requirements of ANSI B16.4 (Class 125). The Series DS-1 Sprinklers may also be installed in the 1 inch NPT out- let of a Grinnell Figure 730 Mechani- cal Tee; however, the use of the Figure 730 for this arrangement is limited to wet pipe systems. Typically, the end sprinkler fitting on a branch line is plugged as. shown in Figures 3 through 11. The DS-1 Sprin- klers cannot be installed into an elbow fitting. For wet pipe systems, the sprinkler drop may be installed as shown in Fig- ure 12. The configuration in Figure 12 may only be used where the sprinkler fitting and water filled pipe above the sprinkler fitting is not subject to freez- ing and, where the length of the DS4 Sprinkler has the minimum exposure length per Figure-14. For wet pipe systems, the OS-i Sprin- klers may also be installed, in the fol- lowing Tycoe CPVC fittings: (P/N 80145)1" x 1" NPT FemaleAdapter or (P/N 80249)1" x 1" x 1" NPT Sprinkler Head Adapter Tee For dry pipe systems, only use the side outlet of maximum 2-1/2 inch size ORDER LENGTHS: I. 5-1/2' to 48"(139,7 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF I— SPRINKLER FITTING MINIMUM 2-1/4"(57.2 itvn) DEFLECTOR TO MOUNTING SURFACE 3.51 5/16' SPRINKLER FITTING (7,9mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 11 TY3355 HORIZONTAL SIDEWALL w/o ESCUTCHEON TFP500 Page 5 of 8 reducing tee's when locating the DS- 1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete drainage of water from above the DS4 Sprinklers and the branch line. NOTE Do not install the Series DS-1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- don of ice over the inlet Plug or bind- ing of the inlet Plug; or, insufficient engagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protect- ing areas subject to freezing tempera- tures (e.g., sprinkler drops into freez- ers), consideration must be given to the appropriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduc- tion. When the temperature surround- ing the wet pipe sprinkler system is maintained at a minimum temperature of 40017/4°C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40017/40C - Ref. Figure 14): 12 inches (300 mm) when the tem- perature within the protected area is -20°FI-290C 18 inches (450 mm) when the tem- perature within the protected area is -40°F/-400C 24 inches (600 mm) when the tem- perature within the protected area is -60°F/-510C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the protect- ed area may be determined by interpo- lating between the indicated values. The 2007 edition of NFPA 13, Sec- tion 8.4.10.2 requires that dry sprin- klers connected to wet pipe sprinkler systems protecting insulated freezer structures have the clearance space around the sprinkler barrel be sealed. The use of the Model DSB-2 Dry Sprinkler Boot described in Technical Data Sheet TFP59I, and illustrated in Figures 15 and 16, will meet the intent of NFPA 13. TO WET SIDE SYSTEM OUTLET PLUGGED HEATED AREA - 1INCH DSB-2 NPTTEE INTENDED (SEE DESIGN FOR FREEZER CRITERIA STRUCTURES., SECTION) FIGURE 12, SPRINKLER FITTING IN HEATED AREA RUN OUTLET' LUGGED 'F(SEEDESIGN INCH TTEE TO DRY SYSTEM CRITERIA SECTION) I I AREA I SUBJECT I DSB-2 I TO INTENDED FOR FREEZER FREEZING .S STRUCTURES FIGURE 13, SPRINKLER FITTING IN UNHEATED AREA FACE OF SPRINKLER - FITTING HEATED EXPOSURE AREA LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES , FIGURE 14, EXPOSURE LENGTH STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4' DIA. (44.5 mm) - CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER 1-314 01k (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB-2 BOOT STRAP TIES (ENDS ON OS_i OPPOSING SHOWN WITH SIDES OF STANDARD BOOT) ESCUTCHEON FIGURE 16 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER Page 6 of 8 TFP500 Installation The Series DS4 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS-1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C rating to 1/8 inch (3,2 mm) for the 360°F/1820C rating. A 1 inch NPT spnnkler joint should be obtained with a minimum to maximum torque of 20 to 30 ft. tbs. (26,8 to 40,2 Nm). Higher levels of torque may dis- tort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit Step 1. Pendent sprinklers must be installed only in the pendent position, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W-Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W-Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer- piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling), and then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Tycoe Series OS-i Dry Type Sprin- klers must be maintained and ser- viced in accordance with the following instructions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tems must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weep- age past the Inlet seal and that the sprinkler needs to be removed for de- termining the cause of leakage (e.g. an improper installation or an ice plug). The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprin- kler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of theirfire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. The installing contrac- tor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP500 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty Is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, Strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foreaolna warranty is made in lieu press or implied. Including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Dry Sprinklers: Contact your local distributor for availability, and please specify the following: 1. Sprinkler. Model/SIN. Standard Response, Standard Coverage, Dry Type Sprinkler Deflector Style. 5.6 K-factor. Order Length. Dry Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 11, as applicable. After the mea- surement is taken, round it to the nearest 1/4 inch increment. Inlet Connection (1 Inch NPT or ISO 7-Ri) Temperature Rating. Sprinkler Finish. Escutcheon Style and Finish, as applicable. Part Number from Table B. (Part numbers are for 1 inch NPT stan- dard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W-Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. Model DSB-2: Specify: Model DSB-2 Dry Sprinkler Boot*, P/N 63-000-0-002. * Includes one Boot, two Strap lies, and 1/3 oz. of Adhesive (quantity of adhesive is sufficient for installing one Boot) Page 8 of 8 TFP500 P/N 60- XXX- X- XXX I I SPRINKLER ESCUTCHEON I MODEL/SIN FINISH FINISH (2) I I ORDER LENGTH (1) (EXAMPLES) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" 96 Pendent W/ Standard TY3255 Escutcheon (1" NPT) (Fig. 5) 93 Pendent w/ Deep TY3255 - Escutcheon (1" NPT) (Fig. 6) 97 Pendent w/ Std. Recessed TV3255 Escutcheon (1" NPT) (Fig. 3) 92 Pendent w/o Escutcheon TY3255 - (1"NPl) (Fig- 7) 94 Sidewall w/ Standard TY3355 Escutcheon (1" NPT) (Fig. 9) 53 Sidewall w/ Deep TY3355 - Escutcheon (1" NPT) (Fig. 10) 54 Sidewall w/o TY3355 - Escutcheon (1" NPT) (Fig. 11) I 98 Upright w/o Escutcheon I 1V3155 (1"NPT) (Fig. 8) 1 NATURAL BRASS WHITE 4 WHITE POLYESTER WHITE 9 CHROME PLATED CHROME 0 CHROME PLATED WHITE 3 WHITE (RAL9O1O)4 WHITE (RAL9O1O)* 2 NATURAL BRASS BRASS PLATED TEMPERATURE RATING (3) 135F/57C _L 155F/68C 175F/79C 200F/93C _:. 286F/141C 5 360F/182C NOTES Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. Escutcheon Finish applies to sprinklers provided with escutcheons. 286F/141C and 360/182C temperature ratings apply to non-recessed sprinkler assemblies. * Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES DS-I, STANDARD RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7-RI Connection, e.g., 1-60-961-1-180) 0 2007-2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 tqco /Fire & Building I Products Technical Services: Tel: (800) 361-9312/ Fax: (800) 791-5500 o9Oo I L L U 114, TM N We Cover All The Action iU Li U Ji/L ILLUSION1T' - 11,2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® ILLUSION", 11.2 Mac- tor, Standard Coverage, Extra Large Orifice Concealed Pendent Sprinklers are decorative, fast response solder type sprinklers featuring a flat cover plate designed to conceal the sprin- kler. When limited water pressure is available and a higher applied water density is necessary, the ILLUSION is the best choice for architecturally sen- sitive areas such as casinos, hotel lob- bies, office buildings, churches, and restaurants. provide a measure of flexibility with regard to which the length of fixed pipe drops to the sprinklers must be cut. The ILLUSION Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed for installation, and it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceil- ing hole into plasterboard, ceiling tiles, etc. by gently pushing the ceiling prod- uct against the Protective Cap. When the ceiling installation is complete, the Protective Cap is removed and the Cover Plate Assembly installed. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of sus- pended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the Sprinkler provides for 3/4 inch (19,1 mm) of vertical adjustment to As an option, the ILLUSION Pendent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 4). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. NOTICE The ILLUSION Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties ha ving junsdiction. Failure to do so may impair the performance of these devices. Sprinkler Identification Number TY5521 IMPORTANT Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. The owner is responsible for maintain- ing their fire protection system and do- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Page 1 of 6 MAY, 2008 TFPIS4 Page 2 of S TFPIB4 Technical Data Approvals UL and C-UL Listed. (The listings apply only to the service conditions indicated in the Design Cri- teria section.) Approvals for Air & Dust Seal UL and C-UL Listed for use with the ILLUSION (TY5521); however, use of the Air & Dust Seal changes the sprin- kler response rating from quick to standard. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 11.2 GPM/psi112 (161,3 LPM/bar112) Temperature Ratings 160°F/71*C Sprinkler! 139F!59C Plate 2120F!100eC Sprinkler! 165F/74C Plate Adjustment 3/4 inch (19,1 mm) Finishes Cover Plate: Refer to Ordering Proce- dure section. BODY (314 NPT) - CAP SADDLE - SUPPORT CUP WITH - ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING DEFLECTOR - THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SEALING ASSEMBLY SPRINKLER WRENCHING HEX COMPRESSION SCREW LEVER _ J I II I SOLDER LINK I I I 7 ThI I ELEMENT I I I I I I I I I I I I I I DEFLECTOR I --------... I (OPERATED POSITION) I I I SPRINKLER!SUPPORT CUP ASSEMBLY I I I I I RETAINER WITH THREAD DIMPLES EJECTION SPRING Physical Characteristics Body ...............Brass Cap ..............Bronze Saddle .............Brass Sealing Assembly .......... Beryllium Nickel wlleflon* Solder Link Halves .......Nickel Lever .............Bronze Compression Screw ......Brass Deflector .......Bronze/Brass Guide Pin Housing ......Bronze Guide Pins ......Stainless Steel Support Cup ......Plated Steel Cover Plate ...........Brass Retainer ............Brass Cover Plate Ejection Spring ..... ...Stainless Steel * DuPont registered trademark. Patents U.S.A. Patent No. 4,014,388. SOLDER TAB Operation When exposed to heat from a fire, the Cover Plate, soldered to the Retainer at three points, falls away to expose the Sprinkler Assembly. At this point the Deflector supported by the Guide Pins drops down to its operational po- sition. When the rated temperature of the Sol- der Link Element is reached, the Link Element separates, allowing the sprin- kler to activate and flow water. COVER PLATEIRETAINER ASSEMBLY FIGURE 1 THE ILLUSION (TY5521) CONCEALED PENDENT SPRINKLER ASSEMBLY COVER PLATE TFPI84 Page 3 0t6 2-1/? DIA. SPRINKLER- (63,5 mm) 314" (19.1 mm) FACE OF SUPPORT CUP i" 7) THREADED SPRINKLER ;SPR E NPT Y PERATEDADJUSThIENT FITflNG INKLER COVER 2-1/8"*318" PLATE - (54,0 mm RETAINER 3W GAP ±9,5 mm) I COVER- SPRINKLER- ] MOUNTING 3/8" (9,5 mm) I RETAINER SUPPORT CUP • SURFACE I ASSEMBLY ASSEMBLY (4.8 mm) 3-3116"DIA. DISPOSABLE \ 1-1/8" (28,6 mm) - DEFLECTOR IN (81,0 MM) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 2 THE ILLUSION PENDENT SPRINKLER INSTALLATION DIMENSIONS Design Criteria The Tyco® ILLUSION (TY5521) Concealed Pendent Sprinklers are UL and C-UL Listed as quick response - standard spray sprinklers for use in accordance with the current NFPA standard; however, in accordance with its UL and C-UL Listing it cannot be used for the protection of storage. The ILLUSION Concealed Pendent Sprinklers are only listed and ap- proved with the ILLUSION Concealed Cover Plates having a factory applied finish. The ILLUSION must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The Tyco® ILLUSIONTm must be in- stalled in accordance with the follow- ing instructions; NOT/CE A 3/4 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 10 to 20 ft.lbs. (13.4 to 26.8 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over-tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the W-Type 18 Sprinkler Wrench (Ref. Figure 3). The W-Type 18 Sprinkler Wrench is to be applied to the Sprinkler as shown in Figure 3. Step S. Replace the Protective Cap (Ref. Figure 2) by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent or exhibiting visible signs of corrosion Care and must be replaced. Page 4 of 6 TFPIS4 damage to the Deflector and Arms dur- ing ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protec- tive Cap. NOTICE As long as the Protective Cap remains in place, the system is considered to be 'Out of Service". Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 4, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 4. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 4) makes contact with the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Maintenance The Tyco® ILLUSIONTm must be maintained and serviced in accord- ance with the following instructions: = Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper opera- tion of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation, if the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission toshut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. if a Cover Plate Assembly becomes dislodged during service, replace it im- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in ac- cordance with local requirements and/or national codes. TFPIB4 Page 5 of B Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted bylaw. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability. Sprinkler Assembly: Specify: TY5521, (specify temperature rating) ILLUSION Pendent Sprinkler, PIN (specify). ISVFITVC 21F11OC TY5521 50-711-1-160 50.711-1-212 Separately Ordered Cover Plate: Specify: (specify temperature rating) ILLUSION Cover Plate with (specify finish), P/N (specify). 139F15YC(a) 185FR4C(b) Brass .......56-892-1-135 56.892-1-185 Chrome .....56.892-9-135 58-892-9.165 Signal White (c) (RAL 9003) . . 56.892-4-135 56-892-4-165 Grey White (d) (RAL 9002) . . 56-892-0-135 56-892-0-165 Pure White (e) (RN.. 9010) . . 58-892-3-135 56-892-3-165 Custom .....56-892-X-135 56-892-X-165 For use with 160'F!71C sprinklers. For use with 212F1100C sprinklers. (C) Previously known as Bright White. Previously known as Standard White. Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. Page 6 of 6 TFPI84 0 2008 TYCO FIRE Ri BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 allow easy tightening from many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to V4' (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effec- tive in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. /1'itauiïcr =k-5i.t:i j V27, K5.6 Models V2709 and V2710 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response PRODUCT DESCRIPTION These Model V27, standard spray horizontal sidewall sprinklers are designed for _____ standard or recessed instal- lation. The design provides V2709 a crescent-shaped water Standard V2710 discharge pattern for Instal- Horizontal Sidewall latlon along a wall or under a beam or ceiling. The design incorporates state- of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, pre- cise operation. ( The the cast frame is more streamlined and attractive 27o9 V2110 than traditional sand cast frames. It Is cast with a Recessed hex-shaped wrench boss to Horizontal Sidewall TECHNICAL SPECIFICATIONS Models: V2709, V2710 Style: Horizontal Sidewall or Recessed Horizontal Sidewall Nominal Orifice Size: ½' (13 mm) K-Factor: 5.6 Imp. (8.1 S.!.") Nominal Thread Size: WNPT(l5mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Horizontal Deflector: UNS C22000 Commercial bronze Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5.0 mm U Quick Response: 3.0 mm Load Screw: UNS C65 100 Low Silicon bronze Pip Cap: UNS C65 100 Low Sili- con bronze Seal: Teflon* tape Spring: Beryllium nickel Frame: Die cast brass 65-30 Lodgement Spring UNS S30200 Stainless steel ACCESSORIES Installation Wrench: U Open End: V27 U Recessed: V38-3 Finishes: U Plain brass U Chrome plated U White painted" U Flat black painted** U Custom painted** U Lead** 155, 200, 2865R Only: U Wax' U Wax over lead** For cabinets and other accesso- ries refer to separate sheet. For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. Teflon is a rcgtstcrcd trademark of Dupont Co. UL Listed for corrosion resistanco in all configurations. VICTAULIC5 IS AN ISO 9001 CERTIFIED COMPANY Vlctaulic Company of America Vlcvullc Comreny of Cand Vlctaulic Europo Vlctcullc America Lctlna Victaulic Anla Pacific Phone: 1-800-PICK-VIC (1-800-142-5842) Phone: 416.675.5515 Phone:32-9-381 -1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 416-615-5565 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic@victaulic.com e-mail: viccanada@viclaulic.com e-mail: viceuro@viclaulic.be e-mail: vical@viclaulic.com e-mail: vicap@victaulic.com 2545 Rev.D 1111102 0 Registered Trademark of Victaullc 0 Copyright 2002 Mctaulic Primed in U.S.A. APPROVALSILISTINGS Nominal Approved Temperature Ratings °FIC t 91 K-Factor Orifice Size Imperial Deflector Model lnchesl:nm s.i.* Response Type UL FM@ ULC NYCIMEAI CSFM § ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2709 13 8,1 Standard Horizontal Sidewall 182 57 182 57 182 57 182 SI 182 ½ 5.6 Recessed HSW 135-200 135-200 135-200 135-200 135-200 V2709 13 8.1 Up Up to Adjustment 51 93 57 93 51 93 51 93 51 93 V2710 ½ 5.6 Quick Horizontal Sidewall 135-286 135-286 135-286 51 141 135-286 135-286 141 51 13 8.1 141 51 141 1 SI 141 ½ 5.6 Recessed HSW 135-200 135-200 135-200 V2710 13 Quick UptowAdjustment 51 93 51 93 SI 93 135-200a 1193 51 93 ½ 5.6 Recessed HSW 135-200 No 135-200 135-200 V2710 13 8.1 Quick upto~AdJusunt , U 93 51 93 Listings and approval as of pnnting. L2 All arc approved open, except for areas designated No. @ Ught Hazard only. "For K-Factor when pressure is measured in Bar, multiply SI. units by 10.0. t MEA #62-99-E. § CSFM #7690-0531:112 Temperature - °FIC Sprinkler Victaulic Nominal Maximum Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 51 100 33 Orange Ordinary C 155 63 100 39 Red Intermediate E 175 150 79 55 Yellow Intermediate F 200 93 150 85 Green High J 286 1.41 225 - 107 Blue Extra Hight K 360 182 300 149 Mauve - t M Open T No Bulb * Standard response only. All are approved open, except for areas designated "No. - 150165 if wax coated. RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in adjacent table. ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number U Style U Temperature Rating K-Factor U Sprinkler Finish U Thread Size U Escutcheon Finish Quantity U Wrench Model Number -- - Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. - Always wear safety glasses and foot protection. - Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury andlor property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdictiofi may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 180444031, 610-559-3300. - 40.11 -2 DIMENSIONS 3 (89 mm) 2W(57 mm) — (32 mm) (8 in ). 1111 mm) Standard HSW-.V2709, V2710 (17 mm) b IN. 14 mm) (43 mm) (27mn - Finished Ceiling 4- 12'(102T -305 mm) 4- 120 Per NFPA Per NFPA —A. P2 MM) Zxs- (60 mm) T 2W in. ola Max' Hale "- Finished Ceiling -ft 2'(5lmm) 2W(60mm) Mm. Hole Max. Hole Finished Surface -' -4 4— Typical Wall Finished Surface - ._i L Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS ½" Adjustment Recessed — V2709, V2710 (Dmw(rtgnollb scale) 124 mmt (14 mm) 1iAe Ths (58 mm) I (37 mm) (33 mm) ________ __________'- Finished Ceiling Finished Ceiling 4-12'(102-305mm) 4-12'(102-305min) •1— Per NFRk PerNEPA L-0~rt 2' (51 mm) 2% (60 mm) 2' • 2' (51 mm) 20A"(60 mm) Mm. Hole Max. Hole (75 mm) Mm. Hole Max. Hole Finished Surface J L_ Typical Wall Finished Surface L Typical wall MAXIMUM EXTENSION MAXIMUM RECESS - -%" Adjustment Recessed — V2709, V2710 (Thrnvuiq not to scale) AVAILABLE WRENCHES V38-3 Recessed V21 Open End No escutcheon / / With escutcheon / - 40.11-3 URRUUURUUU 2' 0.6 m 4, 1.2 m 6' 1,8 et 8' 2,4 m 10' 3,0 m 12' 3,7 m 14' 4,3 m 16' 4,9 m ipsi 48 kPa 15 psi 103 kPa 30 psi ------ 207 kPa DISTRIBUTION PATTERNS MODELS V2709, V2710 1(5.6 STANDARD HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS - TRAJECTORY 10' Ea-q- 3,0 rn 8' 2.4 m 6' 1,8 m 4, 1,Zm 2' 0,6 m 0 UU•SRUlIU NNEEMENEEMENE MENEWENEEMENE ENEEMENEEMMEN MONEEMENEEMME INEEMENEEMEMEN 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m 4,9m 5,5m 6,11m 6,7m 7,3m 7,9m ipsi 48 We 15 psi 103 kPa 30 psi ------- 207 kPa MODELS V2109, V2110 1(5.6 STANDARD HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS - PLAN VIEW 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 06 m 1.2 m 1.8 m 2.4 m 3.0m 3.7 m 4.3 m 4.9 m 5.5 m 6,1 m 6,7 m 7.3 m 7.9 m 8,5 m NOTES: - Data shown is approximate and can vary due to differences In Installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance In avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings. Approvals and War- ranties. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. Al products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.11-4