HomeMy WebLinkAbout5600 AVENIDA ENCINAS; ; AS160133; Permit5/30/24, 4:20 PM AS 160133 Permit Data City of Carlsbad Sprinkler Permit 5600 AVEN IDA Job Address: ENCINAS Permit Type: SPRINK Parcel No: 2100905000 Lot #: 0 Permit No: AS160133 Status: ISSUED Applied 5/13/2016 Approved: 5/25/2016 Reference No.: Issued: 5/25/2016 PC #: Inspector: Project Title: VERVE WIRELESS ADD NEW PENDANT SPRINKLERS PER RCP LAYOUT IN NON-COMBUSTIBLE CONSTRUCTION. EXISTING UPRIGHT PROTECTION TO REMAIN Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON ST P0 WAY CA 92064 858-513-4949 Owner: MART-CARLSBAD L L C 221 15TH ST DEL MAR CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 325.5 0 325.5 0 about:blank 1/1 1S1 61133 I wE9mERfl' FZ F•'I' (.J rL: Lri D NJ 5600 AVENIDA ENCINAS Western Fire Protection Inc. Verve Wireless 5600 Avenida Encinas Carlsbad, Ca 92008 WESTERN FIRE PROTECTION PROJECT #TIC-1471 Materials Submittal 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 tqcci Fire Protection Products Worldwide www.tyco-fire.com Contacts Series EC-11 and EC-14 Sprinklers, 112 K and 140 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass-bulb sprinklers designed for use in light or ordinary hazard occu- pancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installa- tion rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. Series EC-11 and EC-14 Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific appli- cation listing for use under concrete tees. Series EC-11 and EC-14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprin- klers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion-resistant coatings, where applicable, help extend the life of copper alloy sprinklers beyond that which occurs when exposed to corrosive atmospheres. Although corro- sion-resistant coated sprinklers passed standard corrosion tests of the appli- cable approval agencies, this testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion-resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity should be consid- ered, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE Series EC-11 and EC-14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. NOVEMBER 2014 Sprinkler Identification Numbers (SINs) TY5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent, 14.0K TY5137 is a re-designation for C5137, G1894, and S2510. TY5237 is a re-designation for C5237, G1893, and S2511. TY6137 is a re-designation for C6137, G1896, and S2610. TY6237 is a re-designation for C6237, G1895, and S2611. TFP22O 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2°(12,7mm) J NOMINAL MAKE-IN UPRIGHT ESCUTCHEON PLATE SEATING SURFACE 2 CROSS PENDENT SECTION WRENCH 3/4" FLAT NPT** TFP22O Page 2 of 8 Components: 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) ASSEMBLY Technical Data Approvals TYCO Series EC-11 and EC-14 Extended Coverage Upright, Pendent, and Recessed Pendent Sprinklers are UL and C-UL Listed. Refer to Table A for complete sprinkler approval infor- mation including corrosion-resistant status. The approvals apply to the service conditions indicated in the Design Criteria section. Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are FM Approved. Refer to Table A for complete sprinkler approval information including corrosion-resis- tant status. The approvals apply to the service conditions indicated in the Design Criteria section. The Style 60 Two-Piece Flush Escutcheon (Figure 4) is UL Listed and FM Approved for use with the Series EC-11 and EC-14 Pendent Sprinklers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 gpm/ps11/2 (161,3 1pm/bar112) K = 14.0 gpm/psi112 (201,6 1pm/bar1/2) Temperature Ratings Refer to Table A. Finish Sprinkler: Refer to Table A. Recessed or Flush Escutcheon: White-Coated, Chrome-Plated, and Brass-Plated Physical Characteristics Frame.......................Bronze Button.......................Bronze Sealing Assembly.......Beryllium Nickel w/TEFLON Bulb ...................Glass (3 mm) Compression Screw............Bronze Deflector......................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria TYCO Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indicated below. Only Style 30 or 40 Recessed Escutcheons are to be used for recessed installation, as applicable. Refer to Tables A, B, and C. Hazard Light Table B describes UL and C-UL Sensitivity Rating Table C describes FM Sensitivity Rating Ordinary Table B describes UL and C-UL Sensitivity Rating Table C describes FM Sensitivity Rating Notes Listed by Under Listed by Under Approved by Fac Approved by the Area Style Light Hazard 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) Ordinary Hazard 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - OR OR OR OR OR 14x14 Style 30 Recessed - - - - - OR OR OR OR OR Style 40 Recessed - - - - - OR OR OR OR OR Upright or Pendent OR* OR QR OR OR SR SR SR SR SR 16x16 Style 30 Recessed QR° OR* OR* OR* OR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR* OR° OR OR* OR SR SR SR SR SR 18 x 18 Style 30 Recessed QR* QR° QR° OR* OR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR* OR* OR SR* SR* SR SR SR SR SR 20 x 20 Style 30 Recessed OR° OR* OR SR SR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable Does not apply to Upright K=14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC- 11 OR EC-14 SPRINKLERS (Refer to Table D for Permitted K-Factor/Area Combinations) TFP22O Page 4 of 8 HC-1 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-factor Style Response Min Max Min Max 10 20 100 400 Up to 30 Noncombustible Unobstructed, Noncombustible Obstructed, or 11.2 EC Pendent or Combustible Unobstructed 14.0 EC Upright Noncombustible Unobstructed, 11 2 EC Pendent 10 20 100 400 Up to 30 Noncombustible Obstructed, or 14.0 EC Recessed Combustible Unobstructed Style 30 10 20 100 400 Up to 30 Combustible obstructed 11.2 EC EC Quick14.0 Pendent or Upright 10 20 100 400 Up to 30 Combustible obstructed 11.2 EC 14.0 EC Pendent Recessed Style 30 10 20 100 400 Over 30 and up to 45 Noncombustible Unobstructed 11.2 EC 14.0 EC Upright HC-2 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-factor Style Response Min Max Min Max 10 20 100 400 Up to 30 Noncombustible Unobstructed, 11.2 EC Upright Quick 10 20 100 400 Up to 30 14.0 EC Pendent or _____ Combustible Unobstructed __________ ____ 10 16 100 256 Over 30 and up to 45 11.2 EC 14.0 EC Upright HC-3 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-Factor Style Response I Min Max Min Max 10 t 16 100 256 Up to 30 Noncombustible Unobstructed, 11.2 EC Upright Quick 10 t 20 100 400 Upto3O 14.0 EC Pendentor Upright _____ Combustible Unobstructed __________ 10 f 16 100 256 Over 30 and 11.2 EC, Upright up to 45 14.0 EC NOTE The design for K 11.2 EC (K 160 EC) sprinklers should not include fewer than six sprinklers or have a design pressure of less than 12 psi (0.8 bar); similarly the design for K 14.0 EC (K 200 EC)sprinklers should not include fewer than four sprinklers or have a design pressure of less than 18 psi (1,2 bar). For flow criteria, refer to FM Loss Prevention Data Sheet 3-26. TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-Il OR EC-14 SPRINKLERS (Note: Refer to FM Loss Prevention Data Sheet 2-0 for permitted K-factor/area combinations) UL and C-UL Listing Requirements Series EC-11 and EC-14 Sprinklers may be used for the coverage areas shown in Table 0, based on main- taining the minimum specified flow rate as a function of coverage area and hazard group for all sprinklers in the design area. Series EC-11 and EC-14 Sprinklers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13; for example: Unobstructed, combustible or noncombustible, ceiling construc- tion with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). Obstructed, non-combustible, ceiling construction with a deflector location below struc- tural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). Series EC-11 and EC-14 Sprinklers, specifically tested and listed for non-combustible obstructed construction, are permitted to be used within trusses or bar joists having non-combustible web members greater than 1 inch (25.4 mm) when applying the 4 times obstruction criteria rule defined under "Obstructions to Sprinkler Discharge Pattern Development". To prevent cold soldering, the minimum allowable spacing between Series EC-11 and EC-14 Sprinklers, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. TFP22O Page 5 of 8 Description Area Light Hazard 0.10 gpm/ft2 Group I Ordinary Hazard 0.15 gpm/ft2 Group II Ordinary Hazard 0.20 gpm/ft2 gpm psi gpm psi gpm psi 14x14 30 7.2 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 TY5137 (K=11.2) Upright 18x18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14 x 14 30 7.2 30 7.2 39 12.1 TY5237 16x16 30 7.2 39 12.1 51 20.7 (K=11.2) Pendent 18 x 18 33 8.7 49 19.1 65 33.7 20x20 40 12.8 60 28.7 80 51.0 14 x 14 N/A N/A 39 7.8 51 13.3 16x16 N/A N/A 39 7.8 51 13.3 TY6137 (K=14.0) Upright 18x18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 14 x 14 37 7.0 39 7.8 51 13.3 TY6237 16 x 16 37 7.0 39 7.8 51 13.3 (K=14.0) Pendent 18x18 37 7.0 49 12.3 65 21.6 20x20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 psi = 0.06895 bar 1 ft.2 =0.093 m2 1 gpm = 3.785 1pm 1 gpm/ft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC- 11 AND EC-14 SPRINKLERS Series EC-11 and EC-14 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for extended coverage upright and pendent sprinklers; For example, obstructions to sprinkler discharge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard and clearance to storage. UL and C-UL Specific Application Listing Requirements for Installation under Concrete Tees Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 and TY6237) have a UL and C-UL Specific Application Listing for use under concrete tees when installed as follows: 1. Stems of the concrete tee construc- tion must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m). However, where the concrete tee length exceeds 32 feet (9,8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. 2. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright and pendent sprinklers applies. FM Approval Requirements Series EC-11 and EC-14 Extended Coverage Sprinklers are to be installed in accordance with the applicable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occu- pancies. Information provided in the FM Loss Prevention Data Sheets relates to, but not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to-ceiling distance. These criteria may differ from UL and/or NFPA criteria. Therefore, the designer should review and become familiar with Factory Mutual requirements before proceeding with design. TFP22O Page 6 of 8 2-7/8 DIA. 1/2±1/8 - (73,0 mm) 1/2° (12,7 mm) - (12,7±3,2 mm) 2-1/4° DIA. 1/4 (6,4 mm) FACE OF (57,2 mm) SPRINKLER -r 1/8° FITTING (3,2 mm) FF 3N MOUNTING SURFACE MOUNTING CLOSURE 7T PLATE 1-3/8 (34,9 mm) 1-1/8° (28,6 mm) FIGURE 2 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8' DIA. 5/8±1/4° (73,0 mm) 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) SP FITTING RINKLER - (3,2 mm) wa $ \ MOUNTING / MOUNTING SURFACE ,/ PLATE CLOSURE 1-3/8' (34,9 mm) 7/8' (22,2 mm) FIGURE 3 SERIES EC- 11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FACE OF SPRINKLER FITTING: - 3/8' (9,5 mm) ABOVE TO 1/8' (3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE - SEATING SURFACE: 1/4' (6,4 mm) ABOVE TO 1/2' (12,7 mm) BELOW MOUNTING SURFACE; 3/4' (19,1 mm) TOTAL ADJUSTMENT Installation Series EC-11 and EC-14 Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 3/4 inch NPT sprinkler joint should be obtained by applying MOUNTING 1/8" SURFACE (3,2 mm) CLOSURE 3/4° NPT 2-5/16" (58,7 mm) -MOUNTING 113/16 (46,0 mm) a minimum-to-maximum torque of 10 to 20 ft.-Ibs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler with the deflector parallel to the mounting surface. Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other FITTING SIDE' TOWARDS SPRINKLER FITTING WRENCH RECESS (END °A") FIGURE 5 W- TYPE 3 SPRINKLER WRENCH WRENCH RECESS -.- 1 LtL WRENCH HEX FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH applicable escutcheon) over the sprinkler pipe threads and with pipe- thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. For upright or pendent sprin- klers wrench-tighten using only the 2-7/8° DIA. (73,0 mm) - 2-1/4' DIA. (57,2 mm) INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE IRON REDUCING SPRINKLER FITTING FIGURE 4 SERIES EC- 11 AND EC- 14 PENDENT SPRINKLER ASSEMBLY WITH 3/4 INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP22O Page 70f8 P/N 51 - XXX -X I .1 - XXX SIN SPRINKLER I I TEMPERATURE • FINISH* RATING 893 I 11.2KPENDENT I TY5237 I I 1 I NATURAL BRASS 894 11.2K UPRIGHT TY5137 4 SIGNAL WHITE (RAL9003) POLYESTER 895 14.01K PENDENT TY6237 5 JET BLACK (RAL9005) POLYESTER 7 LEAD COATED 896 14.0K UPRIGHT 1Y6137 * Escutcheon ordered separately 9 CHROME-PLATED 135 135-F (57-C) 155 155-F (68-C) 175 175F(79°C) 200 200-F (93'C) 286 286-F (141-C) 000 OPEN OPEN indicates sprinkler assembly without glass bulb, TABLE E button, and sealing assembly. SERIES EC- il AND EC-14 UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION W-Type 3 (End A) Sprinkler Wrench. For the pendent sprinkler installed with Style 30, 40, or 60 Escutcheon, wrench-tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. Apply the wrench recess of the appli- cable sprinkler wrench (Figure 5 and 6) to the sprinkler wrench flats (Figure 1). Care and Maintenance TYCO Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Frequent visual inspections are recom- mended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards recognized by the Approval agency (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series EC-11 or EC-14 (specify) Sprinkler, SIN (specify), (specify) K-factor, Pendent or Upright (specify) Extended Coverage, (specify) temper- ature rating, (specify) finish, P/N (from to Table E) Recessed Escutcheon, Two-Piece Specify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify) finish, P/N (specify*) Flush Escutcheon, Two-Piece Specify: Style 60 Two-Piece Flush Escutcheon with (specify) finish, P/N (specify*) Refer to Technical Data Sheet TFP778 Sprinkler Wrenches Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001 TFP22O Page 8 of 8 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqca TEFLON is trademark of The DuPont Corporation. Fire Protection Products QUICK RESPONSE "THE INCH" MODEL GL5606 ONE INCH A DJUS TA BLE CONCEALED PENDENT WITH COVER PLATE TO MEET IBC-ASCE/SEI 7 CODES FOR SEISMIC AREAS C, D & E GL BE FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified, when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. The 41/2" diameter cover plate allows for I" clearance around the sprinkler body, and meets the IBC-ASCE/SEl 7 requirements for the use in seismic design categories C, D & E. The GL Series Concealed Sprinkler may be virtually invisible, as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in orderto install the sprinklerwith the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off' designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build-up causes the solder holding the cover plate to the support shell to melt, allowing the cover plate to fall clear. Continued heat build-up causes the 3mm glass bulb to burst, allowing the deflectorto drop down and distribute water in an approved pattern to extinguish or control the fire. TECHNICAL DATA See reverse side for Approval and Specifications. Temperature Ratings- 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) - - - - - Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE Frame - bronze. Deflector - brass. Screw - brass 41/2" diameter plate Bulb Seat - brass • Spring - nickel alloy • Seal - teflon WHITE Bulb - glass with alcohol based solution, 3mm size ADJUSTABLE Drop Pin - stainless steel • Cover Plate - brass CONCEALED PENDENT Upper Escutcheon Assembly - plated steel NOTE: Globe's wrench P/N 332765 must be used to install this sprinkler. SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING I AVAILABLE SPRINKLER I I N.F.P.A. MAXIMUM I CLASSIFICATION I BULB COLOR I I I TEMPERATURES I I CEILING TEMPERATURE I ORDINARY - ORANGE/RED I INTERMEDIATE YELLOW/GREEN 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 (989) 846-4583 • FAX 989-846-9231 APRIL 2009 A-38-EQ BULLETIN GL5606-EQ REV#2 QUICK RESPONSE MODEL GL5606 ONE INCH ADJUSTABLE CONCEALED PENDENT WITH COVER PLATE TO MEET IBC-ASCE/SEI 7 CODES FOR SEISMIC AREAS C, D & E SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES Chrome 5.6 (80 metric) 1/2" NPT 2 1/2" (6.4 cm) White NOTE: METRIC CONVERSIONS ARE APPROXIMATE. APPROVALS SIN K 135°F (57°C) 155°F (68°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) STYLE MODEL FACTOR with plate with plate with plate with plate with plate cUlus 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) Adjustable Concealed GL5606 5.6 X X X X X X Pendent CROSS SECTION 3 718 -4 DIG. MIN.. HOLE IN CEILING I 718 DIN. RED::: CUP- DEPLECTOR DROP PIN 2 3/4 MAX. 1 718 MIN. SUPPORT SHELL CEILING COVER CEILING PLATES WHITE 135°F PART# WHITE 155°F PART# CHROME 135°F PART# CHROME 155°F PART# 332822 332828 332821 332827 S ORDERING INFORMATION SPECIFY Quantity • Model Number Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Adjustable Concealed Wrenches - P/N 332765 GL601BE EIRE SPRINKLER CORPORATION APRIL2009 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Al RPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.gIobesprinkler.com PRINTED U.S.A. BULLETIN GL5606-EQ REV#2 QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE A U TOMA TI C SPRINKLERS GL SERIES UPRIGHT. PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL GLUE FIRE SPRINKLER CORPORATION CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. 'Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (79°C), 200°F (930C), 286°F (141°C) *Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) 'Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass QUICK RESPONSE PENDENT VERTICAL SIDEWALL if3b 4" QUICK RESPONSE HORIZONTAL LPC/CE lFtAIAl I LIt0I7f%t.If Al Lodgement Wire - stainless steel • SIDEWALL Bulb seat - copper • Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size *SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JULY 2012 A-20 BULLETIN GI-5615, REV. #9 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 PRINTED U.S.A. FAX 989-846-9231 www.globesprinkler.com BULLETIN GL561 5, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) Black Polyester 2,3 8.1 (116 metric) 3I4 NPT 2 7/16" (6.2cm) METRIC CONVERSIONS ARE APPROXIMATE. HORIZONTAL SIDEWALL IS 2 9/16'. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAZARD1 135°F 155°F 175°F 200°F 286°F cULus FM LPC CE NYC - DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X - - - X GL4215 4.2 LH X X X X X X - - - X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 7.8* LH/OH X X X X X X - - X GL8118 8.1 LH/OH X X I X X X I X X X X X GL2801 2.8 LH X X X X X X - - X GL4201 4.2 LH X X X X X X - - - X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8° LH/OH X X X X X X X - - X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X - - - SIDEWALLt GL8133 8.1 LH X X X X X X - - - - GL2826 2.8 LH X X X X X X - - - X HORIZONTAL GL4226 4.2 LH X X X X X X - - X SIDEWALL GL5626 § 5.6 LH/OH X X X X X X X - - X GL5627a 5.6 LH/OH X X X X X - - X X - GL8127 § 8.1 LH/OH X X X X X X - - - CONVENTIONAL GL5624 5.6 LH/OH X X X X X - - X X - (OLD STYLE) GL8125 8.1 LH/OH X X X X X - - X X - 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" 106" BELOW THE CEILING. "INSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD °1/2" NPT S ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes e Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2'); P/N 312366 (L.0.) GL60IBE. FIRE SPRINKLER COIORATION JUNE 2012