Loading...
HomeMy WebLinkAbout2638 UNICORNIO ST; ; 81-417; Permit<JI z 0 ;:: C ac C ~ irl 0 IC I[ 0 u ac "' 0 ~ 5 I "' z ~ z 0 s z "' ... :I 0 u <JI ic "' "' ac 0 ~ .-1[ 0 I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license Is In full force and effect. Lie No ______ Class I hereby affirm that I am exempt from the Con· !/oo~0l~~~7,:; ~; ~f~~.~~ 1~c.!l/~,~ county which requires a permit to construct aJter. improve, ~•sh, or repair any structure, pt'IO( to its issuance also requires the applicant tor such pennit to file a signed statement that he ,s lteensed pursuant to the prov,st0ns of the Con· tractOf''s License Law (Chapter 9 commencing with Section n:m ot D1v1s,on 3 ot the Business and Pro-tess,ons Code) Of that ,s exempt therefrom and the basis for the alleged exemptW)n Any violation of Sectt<>n 7031 5 by an applicant to, a permit subIects tne applicant to I civil penalty of not more than five hundred dollars ($500) C I, as owner of the property, OJ my employees _,1th wages as their sole compensat,on, w,11 do the ~. and the structure 1s not intended or offered for sale {Sec 70,,&,4, Business and Professions Code The Contractor's License Law does not a,::,pty to an owner of pmperty who builds or ,mproves thereon and whO does such wM tumselt or through his own empk>yees. provided that such ,mproveme:its are not mtende1 Of offered tor sale II, however the bu1ldmg or improvement ,s sold w1thm one year of complellon, the owner•bullder w,11 have the burden of proving that he did not build or improve for the purpose of sale) □ I, as owner of the property, am exclusively contr-=.11n9 with licensed contractOfs to construct the proJect (Sec 70U, Business and Professions Code: The Contractor's Ltcense Law does not apply to an owner of property who builds or improves ~':~i~~ 7i~nc~~~!~~~ ~~~,~~~~;:.: Ltcense Law) 0 I am exempt under Sec ---,8 &PC tor this reason __ ____ _ __ _ D I hereby affirm that I hawe a cen1hcate of consent to self•1nsure. or a cer11ftcate ol Workers' Compensation Insurance. or a certified copy thereof (Sec 3800. LabOr Code) POLICY NO __ COMPANY _ □ Copy IS filed with the city - □ Cen1hed copy ,s hereby furnished CERTIFICATl OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed 1t the perm,I ,s tor one hundred dollars ($100) or less} I I l I D I certify that m the performance ol the wol1t for I which this permit ,s issued, I shall not employ any ~~te;1;.Yeo":1;~'sa~o~ ~w~r~:11f~,~~l to i NOTICE TO APPLICANT If. afler makm, this Cert, licate or Exemption. you sllOUl<l t>ecome subIecI t') the Workers· Compensa1ton prov,s,ons of !he Labor Code, you must forthwith comply with such pro'tlIs,ons or th,s permit shall be deemed revoked I I I I I I I O I hereby aftum that there 1s a consirucuon teod,ng agency tor the pe-rfOfmance of the wont tor which trus permit 1s issued ISec 3097 Civil Code) I Lenders Name ___________ _ Lenders Adoress __________ _ I I ' USE BALL POINT PEN ONLY & PRESS HARO ---APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS -- CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT 1200 Elm, Carlsbad, California 92006 (714) 438-5525 JOB ADDRESS AV.ST.I OATE OF APPLICATIONII BUSINESS LICENSE # VALUATION PERMIT NUMBER J...f,5 i Utv,~f\, o sJ; RO. ~l JIO -l,,l " OWNER'S NAME I OWNER'S PHONE PRIME CONTRACTOR CONTRACTORS PHONE ii ZONE ?fl ✓lf / 1 l,c!' . ~~/:· -~ OWNER'S MAILING ADDRESS CONTRACTOR'S AOORESS LICENSE NO. PLAN 1.0. # BLOG USE CODE , _. -~4-1.,.-' 1-',I ✓ , ... ~--, ,,. ,~ ~~ ..,, LOT I BLOCK I SUBDIVISION I 2i5~P~C~~/)-4,I~ .,t){_ DESIGNER STATE LICENSE# STANDARD PLAN# BUILDING SQ. FOOTAGE r.t z. ?o7 DESCRIPTION OF WORK -: (' -- DESIGNER'S ADDRESS DESIGNER'S PHONE CoN-,~~\ ~ .f .D, j u/1 II _f: -' I,. I •. L -----F/P F LR ELEV, NO OCC GP EDU . .,. I I • -_ ' ,.,L,, STORIES I , II. f vO NO -- CENSUS TRACT I GP LAND USE I p~( SPACE I RES UNITS I GRADING f'.ERMIT ISSUED I REDEVELOPMENT TYPE OCC LOAD FIRE SPR AREA CONST YO N 0 vO NO vO NO Not Valid Un~s Ahchine IArtifi«f QTY. PLUMBING PERMIT -ISSUE I ,-QTY. MECHANICAL PERMIT -ISSUE .'( ... -SUMMARY/ACCOUNT NUMBER • ,J (.. ' --t -· EACH FIXTURE TRAP ---'-1".1 -INSTALL FURN. DUCTS UP TO 100,000 BTU BUILDING PERMIT -. " EACH BUILDING SEWER -~ V OVER 100,000 BTU SIGN PERMIT I, .. '---.. ,. EACH WATER HEATER ANO/OR VENT ..... BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK f -t--·· ·' EACH GAS SYSTEM I TO 4 OUTLETS -1-BOILER/COMPRESSOR 3-15 HP TOTAL PLUMBING .,, A,.={, I EACH GAS SYSTEM 5 OR MORE MET AL FIREPLACE J. ELECTRICAL ( "''l 'l> ~ "9r.-Y ~ ..,. ... -..... ' I I .I': -EACH INSTA~. ALTER, REPAIR WATER PIPE VENT FAN SINGLE DUCT w ,... MECHANICAL EACH VACUUM BREAKER MECH EXHAUST -HOOOIOUCTS MOBILE HOME l • WATER SOFTNER RELOCATION Of EA FURNACE/HEATER MOBILEHOME PARK INSP EACH ROOF DRAIN (INSIDE) SOLAR ' TOTI.L MECHANICAL STRONG MOTION "'. 1---r . I I . .,, ~ TOT AL PLUMBING ... FIRE SPRINKLERS PUBLIC FACILITIES FEE QTY. ELECTRICAL PERMIT -ISSUE ~ . ..:.. -n, QTY. SOLAR -ISSUE BRIDGE FEE NEW CONST EA AMP/SWT i BKR /f t:;L) COLLECTORS SCHOOL FEE • DISTRICT ~ I PH 3 PH -STORAGE TANKS Carlsbad EXIST BLOG EA AMP/SWT/BKR ROCK STORAGE Encintlas I PH 3 PH PUMP ----· -San D1egu110 REMODEL/ALTER PER CIRCUIT PLAN CHECK FEE HI-~~ I •1 lU ~ San Marcos ll '-< X i TEMP POLE 200 AMPS -f-16{ //)ill( --""' VVI I --, OVER 200 AMPS TEMP OCCUPANCY (30 DAYS) TOTAL ELECTRICAL I fi'ko'.' TOTAL SOLAR TOTAL FEES PAYABLE I r~r>f . -:z.~ I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION ANO PERMIT" ANO 00 HEREBY Expiration. Eve,y permit iuued by th<t Butldlng Off1c,11 unde< th<t prov1s1ons o( 1h11 r AN OSHA P£111i11T IS AEQUIRED FOR IE)CCAYATIONS OYER CERTIFY UNDER PENALTY OF PERJURY THAT ALL .INFORMATION HEREON INCLUDING THE Code shall expire by hm1tabon and become null and •o•d II the building or wort< ~· O" DEEP ANO OEMOUTlON Oft CONSTAUCTlON OF DECLARATIONS ARE TRUE ANO CORRECT ANO I FURTHER CERTIFY ANO AGREE IF A PERMIT IS authorized by such permit II not commenced within 180 days from the date of such STRUCTURES OYER 3 STORIES IN HEIGHT pe,m,1, or lf tho build•~ or work author!Ud by such permit 1a •~ded or ISSUED: TO COMPLY WITH ALL CITY, COUNTY ANO STATE LAWS GOVERNING BUILDING CON• abandoned at anv tome a er the work ,s commenced for a 011n0d of 1 ' "•~• STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY ANO APPLICANT'S SIGNATURE If. OWNER □ CONTRACTOR 0 APPROVED BY DATE KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS ANO t ' EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ---,,, BY PHONE 0 I ' GRANTING OF THIS PERMIT. -----= ~ c--' ~ u:: >, ni 0 a. E Q) t- i 'O 0 (.!) c <'Cl .!:? a. a. <( I ""' C a: 0 u, u, Q) u, u, <( I 3 .Q Q) ~ ,,; u, Q) u 0 a: <'Cl ni Cl @ Q) u C <'Cl C u:: ~ C Q) ~ (.!) 0 0 Q) a. u, C ~ .I:: ~ , /. City 'arlsbad . '" .-A~SBAD, CA 92008 • TEL. (714) 438-5525 Jc~ Address Owner Malling Address Address City State Lie. S. Classlf. Zip Tel. -- City Lie. No. COMPLETE FOR PLAN CHECK ONLY LEGAL DESCRIPTION '.2 ASSESSORS PARCEL NO ..// 5--3 s O -y r DESCRIPTION OF WORK PLAN ID NO. DESIGNER ADDRESS PHONE ,, CONTACT PERSON t.;11 MISCELLANEOUS· RECEIPT I MISCELLANEOUS FEE RECEIPT □ • PLAN CHECK FEE □ VALUATION /I , t J'S: -- □ DEMOLITION □ HOUSE MOVING □ PARKS AND RECREATION FEE □ PUBLIC FACILITIES FEE □ SCHOOL FEE · DISTRICT □ Carlsbad □ Encinitas □ San Diego □ San Marcos □------------'------t------; □-----------'-------t------; □------------------+---- □.---------------:--:---+---____. □------:-------------,!-----;-;---:: /1 TOTAL FEE $ 'WARNING: PLAN CHECK FEES. WHERE NO ACTION IS TAKEN BY TH APPLICANT IN 180 DAYS AND NO BUILDING PERMIT IS ISSUED, FEE AR FORFEITED TO THE CITY. COMMENTS: _______ --'-------,::--:-------i White -Applicant Yellow -File Pink -(1) Finance (2) Data Process Gold -Assessor ) I I REQUEST FOR INSPECTION TIME:, ______ _ INSPECTOR ___________ PERMIT NO .. _______ DATE: ______ _ OWNER ________________________________ _ ADDRESS, __ 24==--~~g_v.:,::._,;_~~'/:........=Ce>~~~_:;;_c_'l.=O=------------ BUILDING □ FOUNDATION □ REINFORCING STEEL □ MASONRY □ GROUT · GUN I TE □ FLOOR AND CEILING FRAME □ SHEATHING □ FRAME □ EXTERIOR LATH □ INSULATION □ INTERIOR LATH OR DRYWALL D FINAL PLUMBING □ UNDERGROUND PLUMBING □ UNDERGROUND WATER □ ROUGH PLUMBING 0 TOP OUT PLUMBING □ SEWER AND PL/CO □ TUB OR SHOWER PAN □ GAS TEST 0 WATER HEATER D FINAL ELECTRICAL □ TEMPORARY SERVICE □ ELECTRIC UNDERGROUND □ ROUGH ELECTRIC □ POOL BONDING 0 ELECTRIC SERVICE □ CEILING HEAT D G.F.1. 0 SMOKE DETECTOR D FINAL MISCELLANEOUS □ PLENUM AND DUCTS □ COMBUSTION AIR □ PATIO D SIGN □ GRADING □ DRIVEWAY □ CONDITIONED Al R SYSTEMS □ REFER PIPING D FINAL READY FOR INSPECTION: D MONDAY D TUESDAY □WEDNESDAY D THURSDAY D FRIDAY D A.M. D P.M. SPECIAL INSTRUCTIONS_.....,£-=c.,.....,)Cc....,u.._'/-JT'-------'W~ ...... l.-#-d_'.12'"'---(1\.) ______ ~ ________ _ , (//>~ f<G,?f;ll.. sB~~' ·-~TS:D BY __________________ PHONE NO., _______ _ PERSON TAKING REPORT _______ _ _µ~ _wfi /4 ~ /4) d -P ;?~ 11;u fa~ ~ _iL,_ ~ ~ J;W 7 d ~ ~ YI~ ~ 77 11-AA--• 1~ 10 c1f i~JJ. TIME:. __ ~_;_d{)_::__. __ R_~OUEST .FO~ \ INSPECTION INSPECT!)R" . M-2,4 PERMIT NO .. _______ DATE: OWN ER ______ __. ___ _:_vf_..::C..:........::C=--i,;\ a.~.1a..-i .. -.,.,...,, _____________ _ , -t?--F ...,__, ADDRESS. __ ~?--~..!..._L"a~1!......-...:U=---""~\ -~-==--_.:....;._,!.l ~i)-__________ _ BUILDING 0 FOUNDATION 0 REINFORCING STEEL □ MASONRY □ GROUT· GUNITE □ FLOOR AND CEILING FRAME D SHEATHING D FRAME D EXTERIOR LATH □ INSULATION D INTERIOR LATH OR D FINAL PLUMBING D UNDERGROUND PLUMBING D UNDERGROUND WATER D ROUGH PLUMBING D TOP OUT PLUMBING □ SEWER AND PL/CO 0 TUB OR SHOWER PAN □ GAS TEST 0 WATER HEATER D FINAL ELECTRICAL 0 TEMPORARY SERVICE □ ELECTRIC UNDERGROUND D ROUGH ELECTRIC □ POOL BONDING '--/ □ ELECTRIC SERVICE ?,,. i D CEILING HEAT \ / ,.0 G.F.1. ,,. '.).,'·(.__/ 0 SMOKE DETECTOR ,Jli , D FINAL -J ..._ _________ ____, MISCELLANEOUS D PLENUM AND DUCTS D COMBUSTION AIR □ PATIO D SIGN □ GRADING D DRIVEWAY D CONDITIONED AIR SYSTEMS D REFER PIPING D FINAL READY FOR INSPECTION: D MONDAY D TUESD D THURSDAY D FRIDAY SPECIAL INSTRUCTIONS~ """t ~ ~• REQUESTED BY __ ~....l-\_ __ • __ s..;;___~_JJ----'ch"'"'-~v''--'@"-"-____ PHON E NO. tfq-R -~ Zs1· PERSON TAKING REPORT_-'¥~------ . REQUEST FOR INSPECTION TIME-·--,------ INSPECTOR--~,v..~~~==--------PERMIT NO. ______ DATE:_:+-~-~-,L-~-~...:..1/ __ _ OWNER ________________________________ _ ADDRESS;? /tJ/ D FOUNDATION D REINFORCING ~;,EL/ ~SON RY~~ D GROUT -GUNITE D FLOOR AND CEILING D SHEATHING D FRAME D EXTERIOR LATH D INSULATION D INTERIOR LATH OR D FINAL PLUMBING D UNDERGROUND PLUMBING D UNDERGROUND WATER D ROUGH PLUMBING D TOP OUT PLUMBING D SEWER AND PL/CO D TUB OR SHOWER PAN D GAS TEST D WATER HEATER D FINAL ELECTRICAL D TEMPORARY SERVICE D ELECTRIC UNDERGROUND D ROUGH ELECTRIC __,,_, POOL BONDI CE E .. .I. MOKE ETECTOR FINAL MISCELLANEOUS D PLENUM AND DUCTS D COMBUSTION AIR D PATIO D SIGN D GRADING D DRIVEWAY D CONDITIONED AIR SYSTEMS D REFER PIPING D FINAL READY FOR INSPECTION: D MONDAY VruESDAY □WEDNESDAY D THURSDAY D FRIDAY ~M. A" D P.M. SPECIAL INSTRUCTIONS __________________________ _ . REQUEST FOR INSPECTION TIME:,-~-- INSPECTOR PERMIT NO. DATE/ 'ft,/ t' I ,___________ --------~I OWNER, ________________________________ _ ~~sf~ ADDRESS _ _:C7'-:,__ _________ ___:_ __________________ _ D FOUNDATI 0 REINFORCING STEEL D MASONRY D GROUT -GUNITE 0 FLOOR AND CEILING FRAME □ SHEATHING □ FRAME □ EXTERIOR LATH D INSULATION ~RIOR LATH OR _./o "",:1NAL DRYWAL PLUMBING □ UNDERGROUND PLUMBING 0 UNDERGROUND WATER D ROUGH PLUMBING 0 TOP OUT PLUMBING 0 SEWER AND PL/CO D TUB OR SHOWER PAN □ GAS TEST D WATER HEATER D FINAL READY FOR INSPECTION: c9 ELECTRICAL 0 TEMPORARY SERVICE 0 ELECTRIC UNDERGROUND D ROUGH ELECTRIC D POOL BONDING 0 ELECTRIC SERVICE □ CEILING HEAT D G.F.1. □ SMOKE DETECTOR D FINAL MISCELLANEOUS D PLENUM AND DUCTS D COMBUSTION AIR D PATIO 0 SIGN D GRADING D DRIVEWAY D CONDITIONED AIR SYSTEMS D REFER PIPING D FINAL D TUESDAY D WEDNESDAY D THURSDAY D FRIDAY □™:1~ I) SPECIAL INSTRUCTIONS __ .,,.~'-1,,<----___.,~c....::...-....:.rJ_Y_~-----------------,7 o/' <fv( ..?o y YJA /~ ay-,, (1? > REQUESTED BY_---4,~c.......::~.._ _____________ PHONE NO.~ ,-,. PERSON TAKING REPORT-1,~..g:......&L.-:'-------- REQU·EST FOR INSPECTION TIME-·---- INSPECTOR =!__,,,;.._, PERMIT NO .. ----'£...__/,__-_Y,_/_..,__7_DATE: / ..2. -1 OWNER ____ )h_,__<--+-_G_(,_}"""_~'""=..::.....<..... :.__ ________ 7 _________ _ ADDRESS _ ____;;1.....;:;_;;::_b __,jJ=-------"'7kn--?~...:....;;...~--=~~.=L..=:.=-:.·---------- BUILDING 0 FOUNDATION 0 REINFORCING STEEL 0 MASONRY 0 GROUT· GUNITE 0 FLOOR AND CEILING FRAME 0 SHEATHING ¢_FRAME 0 EXTERIOR LATH 0 INSULATION 0 INTERIOR LATH OR DRYWALL D FINAL PLUMBING 0 UNDERGROUND PLUMBING 0 UNDERGROUND WATER 0 ROUGH PLUMBING 0 TOP OUT PLUMBING 0 SEWER AND PL/CO 0 TUB OR SHOWER PAN 0 GAS TEST D WATER HEATER D FINAL ELECTRICAL 0 TEMPORARY SERVICE !ELECTRIC UNDERGROUND ROUGH ELECTRIC POOL BONDING 0 ELECTRIC SERVICE ~ D CEILING HEAT 8 .,, g f D G.F.1. /;J.' _./ □ SMOKE DETECTOR iJ D FINAL MISCELLANEOUS 0 PLENUM AND DUCTS D COMBUSTION AIR 0 PATIO 0 SIGN 0 GRADING 0 DRIVEWAY 0 CONDITIONED AIR SYSTEMS 0 REFER PIPING D FINAL READY FOR INSPECTION: □MONDAY ~ □WEDNESDAY □THURSDAY D FRIDAY t.:-'1-~ Ji,.~ SPECIAL INSTRUCTIONS _________________________ _ REQUESTED BY_-~___;:;...._ ___________ PHONE NO. y J £ -3 o( ) O PERSON TAKING REPORT ___ £_.:...• __ _ REQUEST FOR INSPECTION a_, 2. ~ TIME:-~l~~---- INSPECTOR ___ • lv1__EA_____;_ ____ PE AMIT No __ z,_,_1_-_i_....l -1J _____ DATE= / I -?v ~u J ' OWNER _____ -+0 ...... .,..c.~C-<"-\,_,Q.....__L-.~c-:,..--=-------------- ADDRESS---9-_0_~------K...6 ------"-W_l')""' __ ;___,-Ul.J\...'.'.Y'.~'----'-'---'.._c.2~-------- BUILDING 0 FOUNDATION , 0 REINFORCING STEEL 0 MASONRY 0 GROUT -GUNITE 0 FLOOR AND CEILING FRAME 0 SHEATHING 0 FRAME 0 EXTERIOR LATH 0 INSULATION 0 INTERIOR LATH OR DRYWALL D FINAL PLUMBING 0 UNDERGROUND PLUMB G 0 UNDERGROUND WATE 0 ROUGH PLUMBING TOP OUT PLUM 0 SEWER AND PL/CO 0 TUB OR SHOWER PAN 0 GAS TEST 0 WATER HEATER D FINAL ELECTRICAL 0 TEMPORARY SERVICE 0 ELECTRIC UNDERGROUND 0 ROUGH ELECTRIC 0 POOL BONDING 0 LE D ECTOR MISCELLANEOUS 0 PLENUM AND DUCTS 0 COMBUSTION AIR 0 PATIO 0 SIGN 0 GRADING 0 DRIVEWAY 0 CONDITIONED AIR SYSTEMS 0 REFER PIPING D FINAL READY FOR INSPECTION, D MONDAY ~T~ D WEDNESDAY D THURSDAY D FRI DAY ~ O P.M. SPECIAL INSTRUCTIONS _____________ Q?:i=--__,__·_S.;__._q.....,__._w>__c___' ---- REQUESTED BY ___ o __ [---=~=----------PHONE NO. Lf '3~-8-;;._/v PERSON TAKING REPORT ____ ~,..~-• __ REQl}EST FOR INSPECTION TIME:. ______ _ PERMIT No._fs,__,_C_-_4"---'l"-1..___DATE: \ \ • ~. 8 ( OWNER ________________________________ _ ADDREss _ __.d-..::.......::,l-:"--"'~--15_,___ _ _:,,Ue:::......!....~"'-'\.._.,(_J!.>:RN=---:..=..._uD~'------------- BUILDING 0 FOUNDATION 0 REINFORCING STEEL 0 MASONRY D GROUT -GUNITE 0 FLOOR AND CEILING FRAME 0 SHEATHING 0 FRAME 0 EXTERIOR LATH 0 INSULATION ELECTRICAL ~MP.ORARY SERVICE ~~ECTRIC UNDERGROUND ¾ROUGH ELECTRIC 0 POOL BONDING 0 ELECTRIC SERVICE 0 CEILING HEAT 0 G.F.1. I ,0 □ SMOKE DETECTOR 0 INTERIOR LATH OR DRYWALL D FINAL ~□ FINAL ~U::'-r--1J;1---1----~ .--------------------, PLUMBING 0 UNDERGROUND PLUMBING 0 UNDERGROUND WATER 0 ROUGH PLUMBING 0 TOP OUT PLUMBING 0 SEWER AND PL/CO 0 TUB OR SHOWER PAN 0 GAS TEST 0 WATER HEATER D FINAL r MISCELLANEOUS 0 PLENUM AND DUCTS 0 COMBUSTION AIR 0 PATIO D SIGN D GRADING D DRIVEWAY 0 CONDITIONED AIR SYSTEMS D REFER PIPING D FINAL READY FOR INSPECTION: D MONDAY D TUESDAY □WEDNESDAY )<'.!.M . D THURSDAY )(FRIDAY 0 P.M. SPECIAL INSTRUCTIONS __ _..E__,&?LLJ_.t.,.':/....._ ___________________ _ REQUESTED BY _____ =:p--4P'O:...~~ ..... }.__._I _,~ ____ PHONE NO. A-3la-2s 2. l D PERSON TAKING REPORT _______ _ REQUEST FOR INSPECTION TIME: __ --,-___ _ INSPECTOR __________ .,,... PERMIT NO OWNER __ ....!..M----=----=C-=--~C~....::::L&:::::;.t..::,1.....!.;...:....:~~--·-------...;...__---- ADDRESS_--yfp _ _____:>~g,:::___]2.,,.__N_~,_C._0....;../2-N __ ; _,,O""-------------- BUILDING FOUNDATION D REINFORCING STE D INTERIOR LATH OR DRYWAL D FINAL PLUMBING D UNDERGROUND PLUMBING D UNDERGROUND WATER D ROUGH PLUMBING D TOP OUT PLUMBING 0 SEWER AND PL/CO D TUB OR SHOWER PAN D GAS TEST D WATER HEATER D FINAL READY FOR INSPECTION: □MONDAY 1A.M. D P.M. D TUESDAY ELECTRICAL D TEMPORARY SERVICE EL;CT~15.uODEBGROUND □~~ .,_,._~.., POOL BONDtN ~ GHEAT ~:;dETECTOR () , tlfV F;;k MISCELLANEOUS D PLENUM AND DUCTS D COMBUSTION AIR D PATIO D SIGN D GRADING D DRIVEWAY D CONDITIONED AIR SYSTEMS D REFER PIPING D FINAL □WEDNESDAY D THURSDAY ~RIDAY BUILDING D FOUNDATION □ REINFORCING STEEL □ MASONRY □ GROUT -GUN I TE □ FLOOR AND CEILING FRAME D SHEATHING D FRAME □ EXTERIOR LATH □ INSULATION □ INTERIOR LATH OR DRYWALL D FINAL PLUMBING ~UNDERGROUND PLUM~ D UNDERGROUND WATER □ ROUGH PLUMBING D TOP OUT PLUMBING ~-EWER AND PL/cg::, D TUB OR SHOWER PAN D GAS TEST D WATER HEATER D FINAL READY FOR INSPECTION: ~□TUESDAY ~"&-~ O P.M. TIME:_,'---'d--~; 3~~-- / o ~ 1--'3-/J ELECTRICAL □ TEMPORARY SERVICE □ ELECTRIC UNDERGROUND □ ROUGH ELECTRIC D POOL BONDING D ELECTRIC SERVICE D CEILING HEAT □ G.F.1. □ SMOKE DETECTOR D FINAL MISCELLANEOUS PLENUM AND DUCTS D COMBUSTION AIR D PATIO D SIGN D GRADING □ DRIVEWAY D CONDITIONED AIR SYSTEMS D REFER PIPING D FINAL □WEDNESDAY D THURSDAY D FRIDAY SPECIAL INSTRUCTIONS __________________________ _ REQUESTED BY __ -=O-l __._C>=-_________ PHONE NO. tf-~ l -?d-I 0 PERSON TAKING REPORT-~~------ - Date I l~/s- Prepared by1 ..:::re, PLA!l CHECK NO. Rl-'-1-11 BU I LOI NG ADDRESS ato 3 <3 ()tl)/ C. ~IZ )/ 10 APPLICANT/CONTACT J/}1C L ,?~1)./ Pr:C'il~ NC. ¢..36 82/c) EU ILDI~G OCCUPANCY TYPE OF CONSTRUCT I ON EiJ ILDING PORTION BUILDING l-1t.111t t,.... .:2"" 7 I o , 7.! 1~0' ~()/ ARE.,\ ¢ -¥ OES IGN!=:R PHONE ------ ·V,\LU ATTON VALUE r:.ULTTPLTE:{ ~~ /04 tf:9'1 I I !.ff. /,6-// I -I I I ' ~ ---{]::(, iq _1\.9 J~ ~ .. - -----I I --· ·--- ' I --i I I Air Conditioning I Commcrc1ul ---- ---Residential :-'ire Sorinl<lers I J Cf r~r~ J I Total Value lJLa.::;-~~,~ 'vU) I ' Eu i ld in 1, :crm it i-·c e .l.l~-00 4-~7J~ Plan Check Fee 3 --------- ----------------·-L4. ••---------•----- INTERDEPARTMENTAL INFORMATION SHEET BUILDING DEPARTMENT B~ILDING ADDRESS: PLANNING DEPARTMENT CJJ,Tdi~: teAPRa LtSBAD r ment ZONE __ ~l---=--------\\ _____ LOT SIZE _________ LOT WIDTH _________ _ UNITS ALLOWED ___________ UNITS PROVIDED ____________ _ PARKING SPACES REQUIRED blL PROVIDED __ ~A-tb--''------ % COVERAGE ALLOWED LLt= PROVIDED U __ BUILDING HEIGHT ALLOWED __________ PROVIDED FRONT SETBACK: SIDE SETBACK: REAR SETBACK: ALLOWED &- PROVIDED======o==~====== INTRUSIONS ot LANDSCAPE & IRRIGATION PLAN COMMENTS: ENVIRONMENTAL PROTECTION REQ: _e~i~e=-....:...M_.:_f-_VL, _____________ _ ,ADDITIONAL COMMENTS, ~ IIM1lf0 SI 11~~ fl!l:tmAlc:: ENGINEERING DEPARTMENT 5 F-D· R.O.W. ______ INDUSTRIAL WASTE _______ IMPROVEMENTS _______ _ SEWER CONNECTION DRIVEWAY LOCATIONS --------------------- GRADING PERMIT -------- LEGAL DESCRIPTION __ £L.~:,_-LL_.:,,,L-____ _,µ.~~e::::zt_r..,tt:~__lCL _ __.._,L---a----,--= ADDITIONAL COMMENTS,J..!'.&,._~~M:::~~~~~~~f::!J-~-d/..__,aa_~~...,fl,.~~~-~~~- FIRE DEPARTMENT SPRiliKLING SYSTEM ___________ FIRE PROTECTION EQUIP. _______ _ FIRE ALARMS EXITS _______________ _ FIRE HYDRANTS LOCATION _________________ _ ADDITIONAL COMMENTS OK TO ISSUE: _____ DATE _______ OK TO FINAL ______ DATE ___ _ WATER DEPARTMENT REQUIREMENTS OF APPROPRIATE DISTRICTS MET ________ DATE ________ _ ,- , . SAN DIEGUITO ENGINEERING, INC. John B. Fox • P.E. CIVIL ENGINEERING SURVEYING SO°IL TESTING Stephen D. Dillemutti • P.E. James A. Laret • P.E. SDE 2338 October 12, 1981 Paul Mcclaine AVENIDA DE ACACIAS P.O. BOX 2004 RANCHO SANTA FE. CA 92067 756-3064 1981 Country Grove Lane Encinitas, CA 92024 Subject: Report of Moisture Content Determination, Lot 473, La Costa Meadows Unit 3, La Costa, California. Mr. Mcclaine: In accordance with your request, we have performed moisture content determinations on the subject site. Two moisture samples were taken at the site at depths of 18 inches and 24 inches. A bulk sample of soil was returned to the lab- oratory for ~ Procter Test to determine the optimum moisture content. Th results of the tests are as follows: Optimum Mois 1.1re Content: Field Moisture Content : 17.0% T-1 @ 12 inches T-2@ 18 inches 29.2% 21.1% Benton Engineering report 71-7-17D, da ted 19 October, 1972, classified soils on the subject site as critically expansive. The above report n ~commends a moisture content of 1 to 3 percent above the optimum at the time of placemen·: of c oncrete . The field test results show a soil moisture content well above the optimum, at 1 2" depth and above 3% at 18" depth. .. .J SDE 2'338 12 October 1981 Page Two The scope of this report is limited to the tests as reported for the subject s ite. No other engineering aspects of site development were considered by this office. If there are a ny a uestions regarding this report, please do not hesitate to contact this office. This opportunity to be of service is sincerely appreciated. Respectfully submitted, SAN DIEGUITO ENGINEERING, INC., ~ RCE 26525 /ZA/js cc: (4) submitted '.• • ' i ; ! • f : l .. ,, .. , .... ~ . ' BENTON ENGINEERING. INC. APPLIED SOil. M ECHANICS -FOUNO>.T IONS 6741 El. C AJON BOULEVAP.D SAN DIEGO. CAUFORNIA 92115 PHILIP H ENK ING B£NTON PllE~IOENY • CIVtL ENGl"'lEER October 19, 1972 La Costa Land Company. Costa Del Mar Road ._ P-ancho La Costa, California 92008 Subject: Gentlemen: Project No. 71-7-17D Grading Permit No. L-5930 Final Report on Compacted Fil led Ground And Classification of Soil Conditions Lots 413 to 584, inclusive And Certain Street Areas La Costa lv\eadows Unit No. 3 Carlsbad, California SAN 01£GO, 583-5654 l.4 MESA· 469-5654 This is to report the results of tests and observations mode in order to inspect the compaction of filled ground placed on certain areas of La Costa Meadows Unit No. 3 in Carlsbad, California,. formerly a port of the County of San Diego.: Th e ril ls were placed during the period between J1;ly 15, 1971 and July 20, 1972. The approximate areas and depths of filled ground placed under our inspection in accordance with the approved specifications are shown on the oHoched Drawing t'-!o. l, entitled "Location of Compacted Filled Ground"" The grading pion used for.the placement of filled ground was prepared by Rick Engineering Company and approved March 15, 1971. The approximate locations at which the tests were token and the final test results are presented on pages T-1 to T-26, inclusive , under the ''Table of Test Resu lts." The laboratory detemina- tions of the maximum dry densities and optimum moisture contents of the major fill materials are presented on pages T-27 and T-28, under the "Labo:-atory Test Results." Some of the maximum dry de nsities shown in the "Tobi e of Te:;t Resulrs'' were combinations of these. The tesl's were taken during the weekly period:.-indicated below: Test Number Week Ending 1 to 4, inclusive July 17, 1971 5 to 2 1, inclusive July 24, 1971 22 to 35, inclusive August 7, 1971 36 to 6;3, inclusive August 14, 1971 64 to 113, inclusive August 21, 197 1 114 to 153, inclusive August 28, 1971 154 to 218, inclusiv~ Septambar 4, 1971 219 to 275, inclusive September 11, 1971 276 to 318, inclusive September 18, 1971 319 to 360, inclusive · September 25, 1Yll --------- Proiect No. 71-7-170 La <;:osl'o Land Company Test Number 361 to 404, inclusive 405 to 456, inclusive 457 to 507, inclusive 508 to 538, inclusive 539 to 570, inclusive 571 to 621, inclusive 622 to 675; inclusive 676 to 701, in;lusive 702 to 771, inclusive 772 to 835, inclusive 836 to 905, inclusive 906 to 924, inclusive 925 to 930, inclusive 931 to 935, inclusive -2-October 19, Week Ending October 2, 1971 October 9, 1971 October 16, 1971 October 30, 1971 November 6, 1971 November 13, 1971 November 20, 1971. November 27, 1971 December 4, 1971 December 11 , 1971 December 18, 1971 December 25, 1971 July 15, 1972 July 22, 1972 107') • , , 4 The final results of tests and observations indicate tho~ the compacted filled ground has been placed at 90 percent of the maximum dry density or greater. It has been determined that the fill materials, compacted to 90 percent of the maximum dry density, have a safe bearing value of 1930 pounds per square foot for one foot wide continuous footings founded at a minimum depth and placed five feet or more inside the top of compacted filled ground slopes. If footings are placed closer to the exposed slopes than 5 feet inside the top of compacted filled ground slopes, these should be deepened one foot below a 1 1/2 horizontal to 1 vertical line projected outward and downward from a point 5 feet horizontally inside the top of compacted filled ground slopes. Tests indicate that the compacted filled ground is adequate to satisfactorily support the proposed wood frame dwellings without detrimental settlements. Expansive clay, silty clay, and sandy clay soils were placed in the upper three feet in certain compacted fill areas and also exist in the upper three feet below finished grade in certain cut areas. The final classifications of the soil conditions existing on each lot ore presented as follows: Lots 413 to 430, 432 to 435, 437 to 441, 446 to -450, 452 to 454, 459 to· 466, 470 to 487, 489 to 510, 512 to 527, Type A -Critically Expansive Soils inclusive inclusive' inclusive inclusive j inclusive inclusive inclusive , inclusive inclusive B ENTON ENGINEERING, INC. lots to 534, inclusive to 540, inclusive to 552, inclusive 554,556,557, 558 563, 564, 570, 574 575, 576 . 578to581, inclusive 584 -3-Odober 19, 1972 Type B -Mcrginally Expansive Soils Lots 431 and 436 Lots 528,529,530,535 542,555,560,565 566, 568, 569, 571 512 and 573 442 to 445, inclusive 451, 455 to 458,. inclusive 467 to 469, inclusive 488, 511 Typa C -Nonexpansive Soils Lots 541 , 553, 559, 561 , 562 567, 517, 582, and 583 It is recommended that the fol lowing special design and precautions be taken for the houses to be constructed on the above lots in order to minimize the possible damaging effects due to differential movements of the potentially expansive soils: 3. 4. 5. Type A Lots Avoid the use of isolated interior piers. Use continuous interconnecte d reinforced footings throughout, and place these at a minimum depth of two feet below tr.e lowest adjacent exterior final ground surface. Reinforce and interconnect continuously with steel bars all interior and exterior footings with one #5 bar at 3 inches above the bottom of the footings and one #5 bar placed l 1/2 inches below the top of the stems of the footings. Exercise every effort to assure that the moisture content of the soils in the upper 18 inches below finished grade is 1 percent to 3 percent greater than optimum at the time of placing foundations and slabs. . . Raised wooden floors that span betw een continuous Footings ore best, or use • concrete slabs with at least 6x6 -10/10 we lded wi re re inforcement and a minimum of 4 inches of crushed rock 3/4 to 1 inch in size beneath al I concrete slabs. A moisture barrier should be provided over the crushed rock and this should be cove red with 2 inches of sand below concrete s'labs . Separate garage slabs from perimeter footings by a 1/2 inch thickness of construction fe lt or equivalent, to allow independent move men~ of garage slobs re lative to perime ter footings. Assure complete seporaHon by extending the felt over the full depth of the Fron~ thickened edge of the garage slab. Al so, cut off the garage door stops at least 1/2 inch above the slab. ' --October 19,. 1972 Provide positive drainaga away from oil perimeter footings with a vertical fol I of at least 6 inches in a horizontal distance of 5 to 6 feet outside the house walls. Type B Lots Those lots listed as Type B lots should follow all the above-listed recommendations with the two fol lowing exceptions: , ... ' ~ 1 . The continuous footings may be placed at a minimum depth of 18 inches below the Iowa.st adjacent exterior final ground surface rather than the two feet recommended for Type A lots. 2. Single #4 bar placed as directed (above) near tops and bottoms of a ll interior and exterior footings may be substituted for the #5 bars recommended for Type A lots. P.ecornmendations 3 to 6, inclusive, as listed for the Type A lots, are also applicable to the Type B lo ts. Only nonexpansive soil conditions were observed in the upper three feet on the Type C lots end therefore specially designed footings and slobs wil I not be required on these lots. Respectfully submitted, BcNTON ENGINEERING, INC. R. C. Remer reviewed by :listr: (4) ( l) ( l ) (2) (2) (2) ~-~~ P~ tivil Engineer Addressee Rancho Lo Costa, Inc. Attention: /v\r. Burton L. K~omer Rick En gineering Company Son Diego County Building Inspection, Vista Office Depart..ient o f County Engineer (1) Attention: Mr . H. M. Taylor (l) Attention: Mr. J~ Sove llo City of Carlsba d Deportment of Building Inspection DENTO N EN GINEERING, INC. RCR/PHB/ew ~ .. t/3/8 /J 1> -j -~ 9/-417 LEUCADIA COUNTY WATER DISTRICT APPI.ICATION FOR SEWER SERVICE Ovmer : s Name Mailing Address ;~;e~; : ':J.;~na: 0-,--. ~ Phone No• 225-8062 __ _ ~:=~=:: ~--Mira ,nJQ i1L.w.st. i-~''_": PtRMIT ISSUED U10N ____ ,.... _ _..,_ _ _,_..w_u:.:;_C4~.u.J.\,.__,__""·------'-=2-il.u.0.,_7_______ ! .::!.'T o;:: !lU!LD!/~G Fc:r.~..:JL Service Address: 2638 Unicor~----- Tract Description: lot 473. Meadows #3 Assess or I s Parcel No . __..2~15.._-_,,3'""'5 .... 0_-4.._.9'---------- ['; ' .. ::: !G rrn:.!IT MUST CE APf-UED FOR UY ? ,;;._ 7-J' Type of Building Single Family No. Units 1 Connection Fee $6Qo an Lat eral Size: 411 611 8 11 Saddle Easement Connection (pre-pd 200.00) 4~ -07) Extra Footage: __ @ $___ Extra Depth: ___ @ $ __ _ Amount Rec'd $_i_°'-~ Ck. No/Cash "'2-7a\,,12 Date 9 -'J--0 -9 Rec • d By G-~~I....J:,:,,:~1- Lateral Fee Prorated Sewer Service Fee Total $ tc~. cri The ~pplication must be signed oy the owner {or his authorized rep r2sentative) of the ~roperty to be served. The total charges must be paid to the District at t he time the application is submitted . .. If a service lateral is required, it will be installed by the Leucadia County Water District. The service lateral is that part of the sewer system that ex tends from the main collection line in the street (or easement) to the point in the stre~t (at or near the applicant's property line) where the service lateral is connected to the applicant's building sewer. The applicant is responsible for the construction, at the applicant's expense, of the sewer pipeline {building sewer) from the appli- cant's plumbing to the point in the street {or easement) where a connection is made to the service lateral. The connection of the applicant's building sewer to the service lateral shal l be made by the applicant at his expense. The connection must be made in conformity with the District's specifications, rules and regulations; and IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT. THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE TmE INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL or{ COI_LEC- TION LINE WITHOUT PRIOR APPROVAL AN D INSPECTION BY THE DISTRICT WILL BE CONSlDERED INVALID AND WILL NOT BE ACKNOWLEDGED. The prorated sewer service fee is based upon the date the District estimat2s that service will begin and covers the balance of the fiscal year. There will be no additional fee or refund if service actually corrrnences on a different date . For succeeding fiscal years, the sewer service fee will be collected on t he tax roll in t he same manner as property taxes. The undersigned hereby agrees that the above information given is correct and agrees to the conditions stated. 9-7---0 -C\ Date ID7 ~?- Account No. . . 1200 ELM AVENUE CARLSBAD, CALIFORNIA 92008 Building Department ~itp of Qtar{g{Jab . RESIDENTIAL ENERGY DESIGN CERTIFICATION Permit No. TELEPHONE: (714) 729-11 81 -------- Issue Date. -------.---- CERTIFICATE .OF. .W.1~LIN.JCE Willi ~ERGY COtJSERVAIION DESIG8 HEQUIREMENTS CDi'ITAINED IN ARTICLE 1, PART 6, TITLE 24, CALIFORNIA AIT-1. CODE . I , 'iJ;,,J , (21 ( ~ / ~ ~ .c::. • , hereby cert i f y that I am fa mi 1 i a r with the state energy _ conservation standard~ mandated in CAC Title 24, Section T20-1401 through 120-1406, and that the · plans and other documents submitted in support of the application for a building permit at ,_2___..._t_?~k-~~-~-C,~n ~rc~'~~•~r✓~1-_______ _ Address _tl_.;;...5_-3_5_o-4____.9_· __ , Assessor's Parcel No. Dated comply with. a 115rr/requi re:ents of the.sereg ul a tions. cSignature £~. = -=::::::::_ t Tit 1 e , ~--.n-,--z-, ( Architect, Engineer, Contractor, Other.) .State License or Certificate No. -------------- Date ✓ ~ -..:2-/'-J-/ Submit to the Building Department with pennit application . . • I' Form 78-101 ' \