Loading...
HomeMy WebLinkAbout2605 UNICORNIO ST; ; 81-326; Permit.,, z 0 ;:: ,c a:: ,c ,j (.) "' C IC I[ 8 a: "' 0 ,j 5 I "' z 3 0 z 0 ~ z "' Cl. ::E 0 (.) .,, a: "' "' a: 0 3 1[ ~ 0 I IHlreby )at I am Ileen, provisions of , •. ,er 9 (commenc • with Section 7000) of Division 3 of the Business and Professions Code, and my license Is In full force and effect. Lie No _______ Class ..&....__._,.; __ I hereby affirm that I am exempt from tne Con· V:~~·~;;~,::: ~w ~t~'::i,owc:Jer9:~1~r county whteh requires a permit to construc1 alter, 1mpr0Ye, demohsh. or repair any structure. poor to its 1sSU¥1Ce also requires the applicant tor such penmt t'o hie a signed statemenl that he ,s lteensed pursuant to tM prov1s1ons of the Con-trac-tOf's License Law (Chapter 9 commencing with Sect.on 7000 of O1v,sK>O 3 of the Business and Pro-fessions Code) or that 1s exempt therefrom ¥ld the ba.Sts tor the alleged exemption Any v10lation of 5ectoon 7031 5 by on oppllCMll l<l< a permit S<Jbjects tne apphcant to a c1v11 penalty of not more than five hundnld dollars ($500) C I, as owner of the property, o, my emptoyees ••th wages as their sole compensation, will do the work. and the structure 1s not intended or ottered tor sale (Sec '°"· Business and Professions Code The Conlractor·s License La* does not apply to an owner ot property who builds or improves thereon and who dOtts such work himself or through his own employees, provided that such 1mprovemeilts are not 1ntende1 or offered lor sale If. however. the building or improvement 1s sold w1thtn one year of completion, the owner-builder will have lhe burden of proving that he dtd no1 build or improve for the purpose ot sale) . □ I, a.s o*ner ot the property, am exclusively contractmu with licensed contractors 10 construct the PfO)eCt (Sec 70U, Business and Protesst0ns Code The Contractor s license Law does not apply to an owner of propeny who builds or improves =~i~ ~~nc::';~!~!~ ~~~i'~~~;;~~·! License Law) 0 I~ exempt under S&c tor this reason ,B &PC 0 I hereby affirm that I ha·.,e a cen1f1ca1e ol consent 10 self-insure, or a cert1f1cate of Workers Compensation Insurance, or a cen,fted copy lhereol (Sec 3800, Ulbo< Code) POLICY NO COMPANY ':,!....Cor,y IS hied with lhe city~ O een,t1ed copy 1s nereoy turn,shed CERTIFICATl OF EXEMPTION FROM WORKERS COMPENSATION INSURANCE (This section neec:i not be completed 11 lhe perm11 ,s to, one hundred dollars (S 100) or less) 0 I cen,ty that 1n lhe performance of lhe work !or which this permit 1s issued. I shall nol employ any pe,son 1n any manner so as to become sub1ec1 to tl'le Workers Compensation Llws of Cahtorn,a NOTICE TO APPLICANT 11, afler makin;i ltllS Cen1 ticate pt EJCemp11on. you should beeome sub1ect t'l the Workers Compensation provisions ol lhe Labor Code. you must f0f1l'lw11h comply w11h such p1ov1s1ons or this perm11 shaJ1 oe deemed revoked 0 I r-e,eby athrm ma1 1nere •s a cons1ruction len<hng agency t()f 1ne perlormance al ll'le work to, whtCh ltHS perm,, IS LSsueo (Sec 3097 C1v1I coese, Lenoer s Name ___________ _ Lenders Address __________ _ U.lC DIUL ru,"1 r cn unLJ O f"IU . .J,> """u ,..-... r,■• -■-...----..■•• ·-. ·--······--···-·-----·---···--·--·------··-... ------------------··-·--· CA 'BAD BUILDING DEPARTMEN T ( \ ,, APPLICATION & PERMIT I 1200. ..-arlsbad, California 92008 (7U) 438-5525 / JOB ADDRESS AV, ST., O>t{jrtF API ,rr0 N1 BUSINESS LICENSE " VALUATION PERMIT NUMBER 2605 Unicornio La Costa RO. t 1 2 -::J 7r9' 130 ,347. OWNER'S NAME I OWNER'S PHONE PRIME CONTRACTOR '/ / CONTRACTORS PHONE • ZONE g I -~Y~ Mark D. Witherall 942-0684 l1t1Yk U/;+.At"'&-A~ '~,.d' ?cn.-~,~y OWNER'S MA, LING AOORESS CONTRACTOR'S AODRESS LICENSE NO. PLAN 1.0. # BLOG USE CODE 2409 A Burgon Ct . 2. 'Yd? .4 If tt ,-o,,.r Ct-3r ,JtJG 1 81 -326 LOT I BLOCK uLSUBOI VISION I ASSESSOR PARCEL NO. DESIGNER .. STATE LICENSE# STANOt~~LA7c1 . -, t; 3eu~j!(:E n,:;. T r i:irlm..r #1 11 i;.-?Rn-,1~ -on 5/Zh? t' .. OESCRIPTION OF WORK -t .& . --i .. r-LLI) n .... ,~.::i~. , •.:-~1o 'C ... Tn11u 1'-••111THT OESIGNER'S AOORESS DESIGNER'S PHONE ~ 1 1 I ~ • I ·o , .,. I . ~--" ' -F/P F LR ELEV. ~ o t :3 ED/ I vO NO CENSUS TRACT I GP LANO USE 1•:rr,~CE 1 RES UrTS 1 GRADING ~ERMIT ISSUED I REDEVELOPMENT \r~ 02.L;~ FIRE SPR AREA 1 ~ YO ND v0 N vO N'fiJ Nor Valid Unlffs Machine ~rtifi«I ?r.r:::I) ' 3.oo ' QTY, PLUMBING PERMIT· ISSUE QTY. MECHANICAL PERMIT· ISSUE SUMMARY/ACCOUNT NUMBER -- 'Lf -EACH FIXTURE TRAP -..,, -,-, -7 INSTALL FURN. DUCTS UP TO 100,000 BTU ,l_l. -~ BUILDING PERMIT .J I ".). Ill'> 7 EACH BUILDING SEWER L .. r, OVER 100,000 BTU , SIGN PERMIT " hi I -~r',J l PLANCHECK~~/. ~J ..,.,A O~J'k, ~:H .8"5" EACH WATER HEATER AND/OR VENT BOILER/COMPRESSOR UP TO 3 HP I EACH GAS SYSTEM 1 TO 4 OUTLETS --z_. (.j BOILER/COMPRESSOR 3-15 HP TOTAL PLUMBING -I I -~L:J. .&I J -. EACH GAS SYSTEM 5 OR MORE 1 METAL FIREPLACE ?. ELECTRICAL --- EACH INSTA~. ALTER, REPAIR WATER PIPE .....,~ kTENT FAN SINGLE DUCT t.L. -MECHANICAL EACH VACUUM BREAKER MECH EXHAUST -HOOD/DUCTS I MOBILEHOME -- WATER SOFTNER RELOCATION OF EA FURNACE/HEATER MOBILEHOME PARK INSP - EACH ROOF DRAIN (INSIDE) SOLAR - LJ ~/ TOTt;L MECHANICAL STRONG MOTION {.,f. I -, ~ ---. --r --ltL-.,---- TOTAL PLUMBING FIRE SPRINKLERS , 21V) I PUBLIC FACILITIES FEE QTY. ELECTRICAL PERMIT· ISSUE QTY. SOLAR • ISSUE BRIDGE FEE NEW CONST EA AMP SWT 1BKR -. COLLECTORS SCHOOL FEE • DISTRICT 1 PH 3 PH STORAGE TANKS Carlsbad EXIST BLDG EA AMP1SWT 'BK R . ROCK STORAGE Encinitas t PH 3 PH PUMP San 01egu110 . ' - REMODEL ALTER PER CIRCUIT ~N CHECK FEE San Marcos JI~ K {)' - TEMP POLE 200 AMPS --·-OVER 200 AMPS ----- TEMP OCCUPANCY (30 DAYS) -------------- --r --- TOTAL ELECTRICAL TOTAL SOLAR TOTAL FEES PAYABLE I 17 tA--11- I HAVE CAREFULLY EXAMINED THE COMPLETED ·APPLICATION AND PERMIT" AND DO HEREBY Expiration Every permit issued by the Budding Off1c1al under the prov1s1ons ofth1s * AN OSHA PERMIT It, REQUIAE0 FOf! EXCAVATIONS OVER CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall expire by hmttat1on a.nd become null and void It the bu1td1ng or work 5' O" DEEP AND DEMOLITION OR CONSTRUCTION OF DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS authorized by such permit ,snot commenced within 180 days from the date of such STRUCT\JRE.S OVER 3 STORIES IN HEIGHT ISSUED: TO COMPLY WITH ALL CITY. COUNTY AND STATE LAWS GOVERNING BUILDING CON· ::~n~ 1!t 1:~y t!:'~He~~h=~~r:~!h::-:.il.~f~~ r~~~'~tr:r;.~ or , STRUCTION, WHETHEH SPECIFIED HEREIN OR NOT l ALSO AGREE TO SAVE INDEMNIFY AND , o;,;dJO CONTRACTOR liJ ~ PROVED BY 1if1li1 KEEP HARMLESS THE CIT'i' OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND APP~ICANT S SIGNA URE If, I EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE f\ ~ BY PHONE 0 I/] .. GRANTING OF THIS PERMIT , --I ... 7 ~ ii: >-<ii 0 0. E Q) f- l -0 0 CJ ~ C m -~ 0. 0. <{ I :,: C a: 0 Cl) Cl) Q) Cl) Cl) <{ I :!: ,Q a; >- Cl) Cl) Q) c.> 0 ct m co 0 §: Q) c.> C m C ii: ::::.. C Q) Q) (5 0 u Q) 0. Cl) C ~ :c ~ INSPECTION TYPE DATE INSPECTOR BUILDING FOUNDATION REINFORCED STEEL I MASONRY _ GUNITE OR GROUT FLOOR & CEILING SUB FRAME ' SHEATHING FRAME EXTERIOR LATH lNSULATION INTERIOR LATH & DRYWALL PLUMBING SEWER AND BL/CO PLUMBING UNDERGROUND I PLUMBING TOP OUT I I TUB AND ~HOWER PAN I ' GAS TEST ELECTRICAL TEMPORARY POWER ELECTRIC UNDERGROUND ROUGH ELECTRIC ' : ELECTRIC SERVICE I BONDING A I G. F. I. -SMOKE DETECTOR . I MECHANICAL I DUCT & PLEM., REF. PIPING HEAT -AIR COND. -SOLAR SYSTEMS VENTILATING SYSTEMS CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED. JOB SITE FINAL PLUMBING ELECTRICAL MECHANICAL GAS BUILDING SPECIAL CONDIT1f1NS ~ CERT OF OCCUP ·.:.,l::.SS~U:...,E!-::D:-------+------r----- FIELD INSPECTION RECORD REQUIRED SPECIAL INSPECTIONS INSPECTION REQ IF INSPECTOR'S CHECKED APPROVAL SOILS COMPLIANCE PRIOR TO FOUNDATION INSP STRUCTURAL CONCRETE OVER 2000 PSI PRESTRESSED CONCRETE POST TENSIONED CONCRETE FIELD WELDING HIGH STRENGTH BOLTS SPECIAL MASONRY PILES CAISSONS - -. . ' ,..__ ( \ , , <[( I -'3 ;.i.y. ' INSPECTOR'S NOTES I DATE - . -· . ,, ·~ - { , - 'I --.. ' ' I• '' . - ' ' ' ~ { ~ , -· Cl) z 0 ;::: 4( a:: 4( ... 0 Ill 0 a: I[ 0 () a: .., 0 ... 5 ~ .., z ~ z 0 ;::: ~ z Ill IL 2 0 () Cl) ir .., ~ a: 0 3 ·1[ O I h• m that I am licensed under provision• .,i,apter 9 (commencing with Section 1000) of Dilllslon 3 of the Business and Profeaslons Code, and my license Is In full fo,ce and effect. Lie No ______ Ctass _____ _ I hereby affirm tl\at t am exempt from the Con· ~~~•~~~~= ~ ~f~~.~~~~~I~ coonty wtuch requires a permit to construct altttf". improve, demohsh, 01 repair any structure, PflO( to its issuance also requires the applicant tor such pemut to ftle a Stgned statement that he 1s ltcensed pursuanl to the provisions ol lhe Con- tractOf's Lteen51 Law fChapter 9 commencing with Secteon 7000 ot Dtv1s1on 3 of the Business and Pro- fns,ons Code) or that 1s e,empt therefrom and lhe basis fOf the alleoe<f exempteon Any violation ot Sectoon 1031 5 by on applteant fo, a penn,t sut>tects Ine apphcant to a c1v,I penalty ot not mo,e than five hundred dollars ($500) □ I, as owner of 1he property, 0< my employees -.1th wages as their .sole compens.atton, will do the ~. and the structure ,s not intended°' offered to, sale (Sec 7044, Business and Professions Code The Contractor's Lteense Law dOes not apply to an owner of property whO builds o, improves thereon and who does such WOOl himself or through tus own employees. provided that such ,mpro...eme:'lts are not 1ntende1 or oft.red for sale II, however, the bu1ldmg or 1mp,ovement 1s sold w1thm one yea, ot completion. the owner-builder will llaVe the burden of provmg that he did not build Of improve tor the purpose of salel □ I, as owner or the property, am e)(clus1vely contractmQ with licensed contractors to construct the protect (Sec 7044, Business and Professions Code The Contracto,·s License Law does not apply to an owner of p,openy who builds or improves thereon. and who contracts for each pro,ects with a contrac:tOf'ls) license pursuant to the Contractor's UCense Law) 0 I am exempt under Sec fo, this reason ___ .8 &PC □ I hereby affirm that I ha.-e a cen1flcate of consent to self-insure. or a cert1t1ca1e of Workers· Compensation Insurance. or a cen1f•ed copy thereof !Sec 3800. Labor Code) POLICY NO COMPANY 0 Copy IS hied With the city O Cen1hed copy 1s. hereby furnished CERTIFICA Tl OF EXEMPTION FROM WORKERS" COMPENSATION INSURANCE (This secttOn need not be compleled ,t the pe,m,1 ,s to, one hundred dollars (S 100) or less) 0 t certify that tn the performance of the wo,1( lo, which this permit 1s issued. I Shall not employ any person ,n any manner so as 10 bec·ome sub1ec1 to the wooers· Compensation Laws of Calltorn,a NOTICE TO APPLICANT II. after makm;1 this Cert, hcate of Exemption. you should beeome sub1ec1 I? lhe Wor11;ers· Compensait1on prov1s.ans of lhe Lat>or Cooe. you must t0f1flw1th comply w11fl such provisions or tn1s permit shall De oeeme<i revoked O I he,eby affirm 11\al inere 1s a construction lend,no agency !Of me perlormance ot the wonc. tor which m,s permit 1s •ssued {Sec 3097 C1vll Code> Lenoer s Name ___________ _ Lenders Address __________ _ USE BALL POINT PEN ONLY & PRESS HAP APPLICANT TO FILL IN INFORMATION WITHIN SHAQF, IWIEA AND DECLARATIONS --------.... )BAD BUILDING DEPARTMENT C, \ _!) APPLICATION & PERMIT L I 120(, , Carlsbad, Callfornla 92008 (71-4) -438-5525 JOB AODRESS %-1/-<71 ~; AV. ST. ,OATE OF APPLICATIONII BUSINESS LICENSE It VALUATION PERMIT NUMBER --. ..,....... -~ ~d-RO. , . , g,-?~~ _,.:...t,,.·' -. ·,., :-·/,;.,. ., -,. ;-/_,. ,I- OWNER"S NAME ·~-~ -,t,' ')/''·,' _¢ I OWNER'S PHONE PR~E-C-0-NT]C~TO~R I} CONTRACTORS PHONE • ZONE ,..,.,.., l ;:/.J ', ~ //. -~ L /~-,z.,~ • \ ;;; ~ . '/1-r_µ~f? 'J ,, ' 't; <f ,Y OWNER"S MAILING ADDRESS CONTAACTOR"S ADDRESS LICENSE NO. PLAN 1.0. # BLOG USE CODE -, •. ~ ' \ '"5. ..,. , _ .. ,,i; 7 E ~ ,.L -;t ..... ,.; ... ----,, .. ?,.--,,.,;v, LOT BL_9CK ' :,J,_suso1v1s10N I ASSESSOR PARCEL NO. OESIGNER STATE LICENSE# STAN OARD PLAN# BUILDING SO. FOOTAGE ,i1lL ~c. /, ~~ ' ;' -' '"'.""f• -·.I -~ 7 ,"':" }:,• ~ DESCRIPTION OF~':;, ~ • // /_A/?,, /. ~.'I/ thL. OESIGNER'S ADDRESS 0ESIGNE R'S PHONE 10/(.5/81 -69.75 --~ -// -0 ---' ~ 0'□01 bBO I 0/l.l'.:i I 81 79.75 ""T:.-d-'~ ..J ,_, i _;,,;~r.,,z-{; ~-..-;:z--....., ., ' -• 1,--F/P F LR ELEV. NO OCC GP EDU _/ V STORIES vO NO -- CENSUS TRACT I GP LANO use I PARKING SPACE 1 RES UNITS I GRADING J'.ERMIT ISSUED I REOEVELOPMENT TYPE OCC LOAD FIRE SPA AREA CONST YO ND vO NO vO NO Not Valid Unlffs Machine Cerrifi«f QTY. PLUMBING PERMIT· ISSUE 7 ,~l) QTY. MECHANICAL PERMIT· ISSUE "°?),C)() SUMMARY/ACCOUNT NUMBER EACH FIXTURE TRAP I INSTALL FURN. DUCTS i.JP TD 100.000 BTU u:----BUILDING PERMIT EACH BUILDING SEWER OVER 100,000 BTU I SIGN PERMIT - EACH WATER HEATER AND/OR VENT BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK EACH GAS SYSTEM 1 TO 4 OUTLETS BOILER/COMPRESSOR 3-15 HP -· TOTAL PLUMBING ,.,_., -EACH GAS SYSTEM 5 OR MORE 7 METAL FIREPLACE "~--ELECTRICAL .. r.J. 7J. -----~ <-r--MECHANICAL /tL '-EACH INSTAl .. ALTER . REPAIR WATER PIPE VENT FAN SINGLE DUCT EACH VACUUM BREAKER MECH EXHAUST -HOOD/DUCTS MOBILEHOME / WATER SOFTNER RELOCATION OF EA FURNACE/HEATER MOBILEHOME PARK INSP EACH ROOF DRAIN (INSIDE) SOLAR TOT.C.L MECHANICAL 11L ~ STRONG MOTION ----, TOTAL PLUMBING FIRE SPRINKLERS 2n~ ' PUBLIC FACILITIES FEE QTY. ELECTRICAL PERMIT -ISSUE _/ _.QTY. SOLAR· ISSUE BRIDGE FEE I NEW CONST EA AMP/SWT/BKR /7..j, C.;;3:·f~ COLLECTORS SCHOOL FEE • DISTRICT 1 PH 3 PH ' STORAGE TANKS Carlsbad EXIST BLDG EA AMP/SWT/BKR ROCK STORAGE Encimlas 1 PH 3 PH PUMP I San o,eguIto REMODEL/ALTER PER CIRCUIT -PLAN CHECK FEE San Marcos TEMP POLE 200 AMPS 1n. , OVER 200 AMPS TEMP OCCUPANCY (30 DAYS) -------- TOTAL ELECTRICAL -r~ _ ,/"(.1J ./ TOTAL SOLAR TOTAL FEES PAYABLE I k:?/, 7.{ I HAVE CAREFULLY EXAMINED THE COMPLETED ·APPLICATION AND PE,MIT. AND DO HEREBY Exp,rabon Every permit ossued by the Budding OIIICl&I undef the provIS10n1 ofth11 * AN OSHA PEAMIT IS REOUIAEO FOfl D--;;J,AT'ONS OY£fl CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall expire by hmitat,on and become null and void If the bu1ld1ng or work 5· o·· DEEP ANO l>EMOUTION OR CONSTRUCTION OF authortzed by such permit 11 not commenced w1th1n 180 days from the date of such DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS permit. or tf the buildlnx or work auth0t1Zed by such permit 1a suapended or STIIJCT\JAES OVER 3 STORIES IN HEIGHT ISSUED: TO COMPLY WITH ALL CITY, COUNn' AND STATE LAWS GOVERNING BUILDING CON· 1band0ned It any 1,me I er the work 11 commenced for a oenod of 180 dav• STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INOEMNIFY AND APPLICANT'S SIGN~TUR0E • ~--OWNERG CONTRACTOR8 APP(\VED BY rf~~t) r/ KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE P~~✓-,J; ,¢;_ "'JL,# BY PHONE 0 _.,.. ' ' . . . 'I tJi f/1 GRANTING OF THIS PERMIT C/ .,. ~ u: i".:' l-~ 0 a. ' E (:; I "O 0 C!) --c ct! -~ a. a. <( I -"' C a: 0 Cl) Cl) Q) Cl) Cl) <( I 3: 0 Qi >- u; Cl) Q) 0 0 c:: ct! .; 0 ~ Q) 0 C ct! C u::: C Q) ~ C!) 0 i3 Q) a. Cl) C ~ .c 3: iNSPECTION TYPE DATE INSPECTOR BUILDING FOUNDATION REINFORCED STEEL MASONRY I GUNITE OR GROUT , FLOOR & CEILING SUB FRAME j SHEATHING FRAME ' EXTERIOR LATH lNSULATION ' INTERIOR LATH & DRYWALL PLUMBING -- SEWER AND BL/CO ; PLUMBING UNDERGROUND PLUMBING TOP OUT ! TUB AND $HOWER PAN I GAS TEST I ' ELECTRICAL I TEMPORARY POWER ' I ELECTRIC UNDERGROUND I ROUGH ELECTRIC I - ELECTRIC SERVICE I BONDING A : G. F. I. -SMOKE DETECTOR. ' MECHANICAL I DUCT & PLEM., REF. PIPING HEAT -AIR COND. -SOLAR SYSTEMS VENTILATING SYSTEMS CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED. JOB SITE FINAL -PLUMBING I ELECTRICAL A en ,,~~ MECHANICAL I _b_-'T ' J'l.•1 GAS ./ l . BUILDING SPECIAL CON'"'11IONS CERT OF ocr W ISSUED . \ ... ?'.1/ 3~ r ' . FIELD INSPECTION RECORD REQUIRED SPECIAL INSPECTIONS INSPECT OR"S NOTES INSPECTION REQ. IF INSPECTOR'S DATE . CHECKED APPROVAL SOILS COMPLIANCE PRIOR TO FOUNDATION INSP STRUCTURAL CONCRETE OVER 2000 PSI PRES TRESSED CONCRETE POST TENSIONED CONCRETE FIELD WELDING HIGH STRENGTH BOLTS . . .. SPECIAL MASONRY I PILES CAISSONS . I I .,-,I .~~ "'-.. ,. .... • ' ' -; . . - ~ -. .1~·~ r1 I..J II .. OJ,(vl~ fP r~ y.,J-~\J7 r di-~ _.,.. , I ~,., rJ t_,..1. ""' Q i, ,.-.-t., . .,-. ~ .... -~ .~ ,-V ] . -. ' ~ ) I '-\ r '-l , ~) -----' -. _, ... t " ·' • .'· ,, f .... _, ,, !. •. ~ ·-I' I~ ,• \ .... " l.1.,. " ,_ /I ·"'· t • '.\ ,., -' I ,'.·.,A,/\." ''. \ ;\" ' /\ • A_,. -/,,~\ ,.,, , ,.11\V/,\1. ,Jf.\'1\\,.\\/\V1,\J.·~.,.'~''"'·1.l~":--,.1•.'."1.~ .. :,\J/',.,,,11\\J,·1.1./~\11 ·, 1, J.,,o~._•,·\ ~,,, \ /.\J,t.;,_,., ,\.., .. ,,J,,1.\,J,u,.J •• _,.\vl 1.1,.,.. ~,~~-• .\ •• ,\,. /2 » ~ ' --~ 1 Q.: r rt i f i r u t .r n f (1) .r r 1 t ,J ,1 11 r tt tf, :::: < _ \ ~ ~ • !) ; ,~-_;,,-7, ( 1 :,;-,-. <~ ?{f;t tj :r ~ CIT)' OF CJ\~LS: I\D \/) _;\1 J t 1 This Certificate issued pursuant to the requirements of Sec lion 306 • -~ •'."-: • E S _ of the Uniform Building Code certifies that at the time of issuance · ~ ~ this structure complies with applicable . ordinances of the City ~ 1 regulating building construction use. ~ ~ ~ i~ u Cl ·f· t· Single Family Dwelling Bid P • N 81-326 ~ ,-. se ass, ,ca ,on ___ __;:;. ____ ___:. _____ ..::____ g. ermot o.________ V ~ Group ______ Type Construction _____ fire Zone ______ Use Zone______ ~ . -..:, Occupant Load . ~ & 0 • 18 .1d. Mark D. W1 therall .A.J,d 2409A Burgos Ct. 3;> /4 wner o uo ong-• • . . . o ress _ ~ ~ BuildingAddress -26_05 Unicorn10 lsbad, CA. 92008 ► ~ ,·". -~--~ ~ ~ ~ ------------------~---1L...:....:=--::...._-1-__ ..!..:...../-~::::!..-.../J.'::J,-a::==-:=±--;?>-~ -~~---~---------~-~ ~ ~ ~ NOTE: Alterotions, changes, additions or cho ate. » ~ (Pos t in conspicuous ploce) ~ ,";:o//V'r~''fv~"'JY/'m~r--::l\~i~'ff\'Tv'~V~'\''~l'':''W'~~'WV''"·f'v'YZ~''v"'~''~'W\'1'':'''f'~I\Vf\':'\'f'r~ ) i t I ! . I ' ... I • '- ~l-~ZCo UJt¼-QA~ ~' UN I C.,Or2.-Y)( 0 s,. ~ ~, ~¾~ ~ ~ ~ .. ESGIL CORPORATION 9320 CHESAPEAKE DR .. S1-'ITE 122 SAN DIEGO, CA 92123 (T14) 560-146~ EC207 RESIDENTIAL ENERGY LAW STATEMENT OF PLAN CONFORMANCE PLAN CHECK NO. Effective July 1, 1978 every proposed residential building must be designed to comply wi th the State Residential Energy Conservation Law before a building permit can be issued. Section A or B of this form must be completed for each residential building permit application. A. STANDARD DESIGN STATEMENT I have reviewed the pla...s being submitted for the prQPosed residential building at 7 (: ll 7 o/A,.,.,. ~u½ 1 (site) for '2?2:,,-::z:/ '#:<Zz:J (owner) and the design submitted substantially confon:i.s to the State Energy Conservation Standards mandated in CAC Title 24, Sections T2O-14O1 through TZO-1414. 1. Total window .md skylight glazing does not exceed 16% of the gross floor area. 2. Ceilings, walls, and floors comply with the prescribed amounts of insulation. 3. 4. s. Electric resistance space heating does not exceed 10% of the annual heat load. No electric service water heating proposed. Complies with mandatory construction requirements lt&,/2v Date /?i<n/ M✓ ?h .. / J Y.2cl z Licensed as (optional) State of CA License B. Date ALTERNATIVE DESIGN STATEMENT No. ( optiona 1) I have reviewed the plans and the required supporting calculations and data being submitted for the proposed residential building at -,.---,.-......--...,..--...,.._(site) for (owner), and the design submitted substantia lly conforms .,---,----=-----,---,---,--by the alternative design method to the State Energy Conservation Standards mandated in CAC Title 24, Sections T2O-14O1 through T2O-1414, including mandatory construction requirements Check all items submitted to document cpmpliance by the alternative design me thod. Items 1 through 4 are required for alternative designs affecting the building envelope. -------1 : 0 Form 1 1 -Project Date Summary 1 0 Form 2 1 -Hourly and Annual Building Heat Loss Rate 1 0 Form 3: -Heat Transfer Coefficient, Proposed Construction Assembly I O For:n 4 1 -Alternative Design Summary -□ -Form -5--Life Cycle Cost Analysis for HVAC Systems (Electrical Resistance Heating) O For:n 6 -Life Cycle Cost Analysis for Service \·later Heating Q Specify Additional Supporting Date Submitted ________________ _ Signature Licens~d as (optional) Revised 9/9/80 State of CA License (optiona l) ESGIL CORPORATION MINIMUM CONST'il.UCTION SP:C!F!CATICNS (Ref: UBC -197~ Edition) These are mini.Clum specifications established by the Unifo?"III Building Code and shall not supersede any more restrictive spec:i.!ic:ation.s shown on the appToved plans. A. Fourua:ion and Underfloor l. Concrete tor footings shall have a minl.lllWII compressive strength of ZOOO psi at 23 days and shall be composed of l part cement, 3 paru sand, 4 parts of l" maxilllWII si:e rock, and not more than 7-1/2 gallons of water per sack of cement. 2. Wood and Earth Separation. round.a.tions supporting wood shall extend at least 6" above the adjacent finish gra.d.r (Sec. 2907(a)) Provide 18" clearance under wood joists and 12" clearance under wood girders. (Sec. 2Sl7(c)) 3. Concrete Slabs. Slabs on il"ade shall be a.t leut 3-1/2" t..'l.ick. (Sec. 2623) 4. Treated Wood. All foundation plates or sills and sleepers on a concrete slab, which is in direct contact with earth, and sills which rest on concrete or masonry foundations, and wood joists closer than 18", or wood girders or supports closer than 12" to the around shall be pressure truted wood or foundation grade redwood. S. Anchor Bolu and Footing Sills. All footing sills shall have full bearing on the footing wall or slab and shall be bolted to the foundation with l/2" x 10" bolts embedded at least 7" into the concrete or reinforced masonry or 15" into unreinforced iI"OUted masonry. Bolts shall be spaced not to exceed 6' on center with bolts not over 12" from cut end of sills. (Sec. 2907 (e)) 6. Underfloor Vents. Underfloor areas shall be ventilated by openings in foundation walls. Wall openings shall have a net area of not less than 1-1/2 sq. ft. for each 2S linear feet or exterior wall. Openin~s shall be arranged to provide cross ventilation and shall be covered with corrosion-resistant wire mesh of not less than l/4" nor 111ore than 1/2" in any dimension. (Sec. 2Sl7(c )) 7. Underfloor Access. Underfloor areu shall be provided with a crawl hole not less than 18" x 24". (Sec. 25l7(c)' 8. Wood Framing l. Lwnoer . All joists, rafters, bealllS , and posts 2" to 4" -;hick shall be No. 2 Grade Douglas Fir-Larch or better. All posts and beams 5" and thicker shall be No. l Grade Douglas Fir-L.arch or bei:ter. (See items Bl-1 for lumber ~ding requirements for studs) 2. 3. 4. s. 6. 7. 8. Wall Bracing. Every exterior wood stud wall and 111ain cross partition shall be braced at each end and at least every 2S feet of len&th with 1 x 4 diagonal let-in braces or equivalent. (Sec. 2Sl8(g)) Cross aridging. Floor j oists and rafters 111ore than 12" in depth and spanning more than S feet shall be supporter' laterally by bridgin& at intervals not exceeding 8 feet. (Sec. 2S06(g)) Provide blocking at ends and at supports of floor joists, and for rafters at exterior walls. Provide blocking at ends and supports of rafters more than 8" in depth. Provide solid blocking at ridge line and at exterior walls on trussed roofs. Double Joists. Floor joists shall be doubled under bearing partitions running parallel with tr.e joists. Rafter Purlin braces to be not less than 45° to the hori;ontal. (Sec. 2S18(h)) (Sec. 251S(d), 9. Rafter Ties. Rafter ties shall be spaced not more than 4 feet on center where rafters and ceiling joists are not parallel. 10. Provide 1/2" minimui:: clearance between top plate of interior partitions and bottom chord of trusses. 11. Provide double top plate with minil!IJJII 48" lap splice. (Sec. ZS18(g)) 12. Nailing will be in complianct with Table 2S-P. 13. !'ire blocking shall be provided for ,..alls over l0'-0" in height. (Sec. 2S l7(f )J, also for· hori:o:it:al shaf•;s 10 ' o .c., a~d for concealed draft opening. 14. Scuds . In one-or two-story buil~ing~. studs for exteri or walls ana lnter1or bearing walls shall be not less t~. 2 x 4 at l6" o.c. Studs for interior nonbearing par titions may be Z x 3 at 16 o.c. Studs 2" -.l" thick and Z" • •·ide and not more than 8 feet loni shall be "stud grade" Douglas Fir•L.arch or better when supporting not more th .. one floor and a roof. J !◄INIMUM CONSTRUCT!ON S?EC!FICATIONS ( continued) 15. An A.!.T.C. C~nificate of Conform:ince for slued l:iminated wood :ne!llbers shall be 6iven to the 3uilding Inspec:or prior co erec:ion. C. Gener:il Materi:il Soecifications 0. E. l. ~10rtar :,Ii.,:. ,tona::-co bo tl.Sed for construction of aia:son:ry walls, found:11:ion 1·,alls, ret:lining walls shall consist of l par,: portland cement, 3-1/2 pans sand and l/4 to l/2 part hydrated li~e or li~e putty. :-1onar m..:t ·•ith plastic cement shall be l part plastic cement to 3 parts sand. 2. Grout Mix. The mix for ~~e p-out shall be l par,: ponland cement, 2-3 parts sand, l/10 part hydr:ited lime or lime putty, and 2 parts gravel. Grout shall attain a :Dini= compressive st::-ength of 2000 psi at 28 days 3. Masonry. The aia:sonry units sh:111 comply with ASTM Spec. C90-i0, Gr:ide ~. for hollow unit concrete blocks. 4. Reinforcing Steel. The reinforcing steel used in construction of reinforced ma.son:ry or concrete st::uct-.u-es shall be deionnea and comply with ASTI-t Spec. A61S -74a, Grade 40. S. Structural Steel. Steel u.sed as structur:il shapes such as wide flange sections, channels, plates, angles shall comply ·•ith ASTM Spec. A-36 . Pipe columns shall comply with ASTM Spec. A-53. Roofing and '//eatherproofing l. :food 3iding. All wood siding shall be placed over an approved, weatherproofing barrier. (Se<:. 1707). Z. Fl:J.Shi.~g Around Openings. Every opening in any exterior wall shall be flashed with sheet 111etal or water- proof building paper. (Sec. l707(b)). :;. Roof Cover'..ng. Wood shingle, split shake, and a.sphalt ~ingle roofs shall not be installed on a :-oof having a pitch of less than 4 inches to 12 inc.~es. Tile roofs shall not be installed on a roof having a pitch of less than 3 inches to 12 inches. 14i.neral surfaced, built-up roofing shall not be installed on a roof having a pitc.~ oi more than j inches to 12 inc.~es . (Table 32-B}. (Note: Sdction 3203(g} allows reduced r-;iof slopes under spe<:ial application requirements.) 4. Wee;i scredd. A weep screed shall be provided at or below the foundation olateline for all exterior stud walis finished on the exterior with stucco. The screed shall be placed a· :ninimu.m of 4 inches 3.bove grade. (Sec. 4706 (e)) General l. Attic Access . Attic areas shall be accessible by an opening not less than.22" :-c 30", With a furnace in the attic, the opening shall not be less than 30" x. 30". (Sec 3205 (a)). 2. Shower Enclosures. Shower ,,.alls must be finished to a height of 70 inches above tho drain inlet with a smooth, hard, nonabsorbdnt surface. (Sec. l7ll(d}}. Glazing used in walls, doors and panels of shower and bathtub ~nclosures shall be fully tempered, laminated safety 6la.ss or approved plastic. (Sec. l ill (f)) . i 3. Electric Meter Enclosure. Contact San Diego Gas & Electric Company, Customer Extension Planning Oepar-.:nent , f~r meter location. All wiring must COffl!'lY with the National Electrical Code. 4 . Fire-warning Systel!IS. Every dwelling unit and every guest room in a hotel or lodging house used :or sle01)ing purposes shall be provided ·.-ith smke detectors con::orming to U. a. C. Standard No , -13-6. In dwelling units, detectors shall be mounted on the ceiling or wall at a point centrally located in ,he corridor or area giving access to rQoms u.sed for sleeping pur;,oses. In an efficiency dwelling unit, hotel sleeping room and in hotel suites, the detector shall be centrally located on the ceiling of the 111ain room or hotel sleeping room. Where sleeping rooms are on an upper level, the detector shall be placed at the center of the ceiling directly above the stair•ay. All detectors shall bo located in accordance with approved =nufacturer•s instructions. When actuated, the detector shall provide an alarm in the dwelling unit or guest room. (Sec. 1210(a)). 5. E;cit Facilities . Every sleeping room below the fourth story shall have at lea.st one operable ·.-indow or exterior door approved for emergency egress or rescue. The units shall be operable from the inside to provide a full clear opening without the use of separate tools. All egress or rescue windows :rom sleepini roo111S shall have a minimum net cnar opening of S.7 square feet. Tho minil!!UJII net clear opening height dimension shall be 24 inches . The minimum net clear opening width dimension shall be 20 inches. Where windows are provided iJ.S a aieans of egress or rescue they shall have a finished sill heijht not aore than 44 inches above the floor. 6, Glass and Glazing. Glass and glazing shall satisfy the provisions of Chapter 54. Feder:il specifications shall take precedence. See your glazing contr1ctor. These au.n.:.IIIUIII specifications become part of the approved ;,lans ·.-hen included ·•ith the approval of the constr..tction plans. Construction shall comply to these specifications or any more restrictive specifications shown on the approved plans. -2- - 0 :i t C 1 ~\~ 1~, Prepared by, .:::ru, O F:sgi 1 P LA 11 CHECK NO. <8 1-::,Z(°p EU I LOI NG ADDRESS APFLICANT/CONTACT EUILDING OCCUPANCY -Z<tDS' u t0 , c.o e rv, o cnt<::~ Pi!Otl E NO . --------- o :=:S TGNER PH ONE ------ TYPE OF CONSTRUCTION CNIT~AC'!'OR ?HO NE ----- 5U ILDING PORTION BUILDING ARE,\ ·V,\LUATION VALUE r-1ULTT PL I EH L1v,~ ~~t;: a.z~ 1a 3 ~70 \ T , ~ ½¥1,(~ S-Co~ \\~ ~ \ '\3 - .. ------ I --· - ·-- I I I ' I I l ' I ~ I Air Conditionin,e: T I Commerc1nl -- \ -r-1 t'. I I - (\ 0 ~ J, /?t) 0 (.,. Residential -::::-I --.....:::_;_,, :''ire Sorinklers -I. . II II I I I t> V I Total Value \'2.', 4-~~ ( -• Bu ild i n ~ rcrm i t ~c c Plan Ch e c k Fee '2,.c) C ('y_-,,, p ; TS : _ ._-'----------------------------- ---~-·-----·---.•• ---------·------------------------- ------·--------··------ I . f·h f b11c, ._:. pure s c.,.kL, /J~·/.tJ. ..u,. u.....,, 'h-" ) GLv ~1/ S 1/i; \l- Glfo ~ t \ ~ '>AA .,,_,, ,p \lo-\'. C u C,0 .. xi' ' , ,_9.1. (,' .1 '"\ I v ~ INTERDEPARTMENTAL INFORMATION SHEET ,ECEIVED BUILDING DEPARTMENT / DATE: AUG 3 1981 o( b CJ S---')14-11",(:,m_ &, ~.c: CITY OF ~RLSBAD BUILDING ADDRESS: c;? 1 ~-_ .::)_ cY O _ 1/ 3 Building apartment PLANNING DEPARTMENT ZONE __ ~tz~-_l _____ LOT SIZE _________ LOT WIDTH ________ _ UN·~·ls ALLOWED UNITS PROVIDED ------------------------ PARKING SPACES REQUIRED % COVERAGE ALLOWED BUILDING HEIGHT ALLOWED -+D+fl-V-------PROVIDED __ _,_0_1_(_., ____ _ PROVIDED ------------- PROVIDED ---------- FRONT SETBACK: SIDE SETBACK: REAR SETBACK: ALLOWED PROVIDED ___ Q-~,__ __ INTRUSIONS LANDSCAPE & IRRIGATION PLAN COMMENTS: ENVIRONMENTAL PROTECTION REQ: ADDITIONAL COMMENTS: OK TO ISSUE: ENGINEERING DEPARTMENT s , ( 1j ,()1 3y 1. - ______ IMPROVEMENT s~ .1 J\ c~ ✓ t l'Jf"""-·Y R.O.W. ______ INDUSTRIAL WASTE SEWER CONNECTION DRIVEWAY LO CATIONS --------------------- GRADING PERMIT EASEMENTS DRAINAGE LEGAL DESCRIPTI-ON--;;:;;x---# / () -b------L-,-(_-~--. #--_I __ _ --~-------,.,~--------------~~------ ADDITIONAL COMMENTS ----------------------------- FIRE DEPARTMENT SPRI~KLING SYSTEM FIRE PROTECTION EQUIP. ------------------- Fl RE ALARMS EXITS _______________ _ FIRE HYDRANTS LOCATION _________________ _ ADDITIONAL COMMENTS OK TO ISSUE: _____ DATE _______ OK TO FINAL ______ DATE ___ _ • WATER DEPARTMENT ' REQUIREMENTS OF APPROPRIATE DISTRICTS MET ________ DATE _____ _ PHILIP HENKIN O ISENTON ""c:atol[HT • CIVIL IINGINl:1:11 Mr. Mark Witherell 2409-A Burgos Court Carlsbad, Cal ifomia 92008 B E NTON E NGINEERING, INC. Al"PLIEO SOIL "'ECHANICS -FOUNOATIONS llll40 RUFFIN ROAD SAN DIEGO, CALIFORNIA 92123 September 29, 1981 TELU'HONE I 714 ) 568-11185 Subject; Project No. 81-9-25M ~tJr tl/JICO/lAJ/o iV.oishJre Contents in Subgrode Soils ----------...., Lot 106 of La Costa Meadows Unit No. 1 _...,,,.. '- Carlsbad, California Dear Mr. Witherall: This is to report the results of tests to determine the moisture contents of the soils in the upper three feet below finished grade in the proposed building area at the subject site in Carlsbad, California. The soil samples were obtained on September 28, 1981 and the results of the moisture determinations ore presented as follows: Approximate Location of Samples Northwesterly portion of proposed building area Southeasterly portion of proposed building area Depth Below Existing Grade (in feet) 1.0 2.0 3.0 1.0 2.0 3.0 iV.oisture Content (% dry wt) 22.8 21.8 15.4 22.9 24. 1 20.3 It is concluded from the field observations of the various soil types and the final results of the moisture determinations that the soils in the upper three feet below finished grade at the locations sampled have been sufficiently moistened to minimize the potential exponsion of the sol ls, as recommended in our report under Project No. 70-10-280 dated October 12, 1971. It is recommended that positive drainage, 6 inches of vertical fall in 6 feet horizontally, should be provided around the perimeter of the house in landscaped areas. Drainage systems should also 1 Mr. Mork Witheroll etoject No. 81-9-25M -2-September 2.9, 1981 be provided to col le ct al I runoff from roofs and conduct the water in watertight pipes either into the streets or storm drains. All surface drainage should be prevented from ponding adjacent to or running over the tops of slopes. Inlet boxes and watertight pipes should be installed when necessary to comply with the above requirements. Respectfully submitted, BENTON ENGINEERING, INC. By £.C::~ R.C. Remer Distribution: (3) Addressee RCR/PHB/jr BENTON ENGINEl!:"ING, INC. . • 5-22-79 LEUCADIA COUNTY WATER DISTRICT APPUCATION FOR SEWER SERVICE Owner's Name Mark Witherall Phone No . 942-0684 Mailing Address 2409"A" Burgos Ct. ~~ PERMIT tsslJEO UPON (~~ Carlsbad, CA 92008 ~ ~-e.:~ OF BUILDING PERMITA ' Service Address: Lot 106 L.C. Meadows #1 OU\~'\lG PERMIT MUST BE~ Tract Description: _______________ _ Assessor I s Paree l tlo. 215-280-43 APPLIED FOR SY o-.?Q • --==-=--=-==.--'-=---------- Type of Building __,........_.__ _____ No . Units 1 Connection Fee $ 600.00 l.ateral Size: 411 611 811 Sadd l e Easement Connection pre-pd. 200 .00 Extra Footage : __ @$ ___ _ Amoun t Rec'd ~ Ck. Mo/Cash ~ =:tAC?q Date ~ Rec'd By ~O 1..0· Extra Depth: ___ @$ __ _ l.ateral Fee Prorated Sewer Ser vi ce Fee Total $1.o(X),(D The application mu st be signed by the owner (or his authorized representative) of the property to be served. The total charges must be paid to the District at the time the application is submitted. If a service lateral is required, it will be installed by the Leucadia County Water District. The service lateral is that part of the sewer system that extends from the main collection line in the street (or easement) to the point in the street (at or near the applicant's property line) where the service lateral is connected to the applicant's building sewer. The applicant is responsible for the construction, at the applicant's expense, of the sewer pipeline (building sewer) from the appli- cant's plumbing to the point in the stree·~ (or easement) where a connection is made to the service lateral . The connection of the applicant's building sewer to the servi ce lateral shall be made by the applicant at his expense. The connection must be made in conformity with the District's specifications, rules and regulations; and IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT. THE APPLICANT, OR HI S AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE TIME INSPECTION IS DESIRED . ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC- TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND WILL NOT BE ACKNOWLEDGED. The prorated sewer service fee is based upon the date the District estimates that service will begin and covers the balance of the fiscal year. There will be no additional fee or refund if service actually commences on a different date. For succeeding fiscal years, the sewer service fee will be collected on the tax roll in the same manner as property taxes. The undersigned hereby agrees that the above information given is correct and agrees to the conditions as stated. Owner's 7efnature \QloQ9 Account No .