Loading...
HomeMy WebLinkAbout2445 CALENDULA LN; ; CBRA2023-0223; PermitBuilding Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 11/04/2024 Job Address: 2445 CALENDULA LN, CARLSBAD, CA 92008-3748 Permit Type: BLDG-Associated Permit Residential Work Class: Parcel#: 2071013500 Track#: Valuation: $349,873.35 Lot#: Occupancy Group: R3/U Project#: #of Dwelling Units: 1 Plan#: Condo CT 16-07 DEV16038 Bedrooms: 3 Construction Type:V-B Bathrooms: Occupant Load: O Code Edition: 2019 Sprinkled: Yes Project Title: MARJA ACRES Orig. Plan Check#: PC2022-0005 Plan Check #: PC2023-0044 Permit No: Status: CBRA2023-0223 Closed -Finaled Applied: 12/13/2023 Issued: 04/23/2024 Finaled Close Out: 11/04/2024 Final Inspection: 10/29/2024 INSPECTOR: Renfro, Chris Alvarado, Tony Description: MARJA ACRES: (CORAL RIDGE) PHASE F5 // BLDG F13 // UNIT 12S // 1739 SF LIV// 476 SF GARAGE Applicant: KB HOME COASTAL INC ELIZABETH SHOEMAKER 9915 MIRA MESA BLVD, # 100 SAN DIEGO, CA 92131-7001 FEE ATTACHED ACCESSORY & UTILITY USES DUP FLRPLN SFD & DUPLEXES PARK IN-LIEU ATTACHED(> 4 UNITS) NW PUBLIC FACILITIES FEES -outside CFO SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SMIP) Total Fees: $20,742.93 Total Payments To Date: Building Division $20,742.93 Contractor: KB HOME COASTAL INC 9915 MIRA MESA BLVD, # STE 100 SAN DIEGO, CA 92131-7001 (951) 691-5300 Balance Due: AMOUNT $930.96 $1,316.92 $6,190.00 $12,245.57 $14.00 $45.48 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY for (CBRA2023-0223) Permit Type: BLDG-Associated Permit Residenti: Application Date: 12/13/2023 Owner: Work Class: Condo Issue Date: 04/23/2024 Subdivision: RANCHO AGUA HEDIONDA POR Status: Closed -Finaled Expiration Date: 04/28/2025 IVR Number: 53810 OF Address: 2445 CALENDULA LN CARLSBAD, CA 92008-3748 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Status BLDG.:SW-lnspection 266244-2024 Passed Tony Alvarado Complete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 10/30/2024 10/30/2024 BLDG-71 Set Ups 266305-2024 Passed Tony Alvarado Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency B-59 form and receipts verified. Yes Monday, November 4, 2024 Page 6 of 6 PERMIT INSPECTION HISTORY for (CBRA2023-0223) Permit Type: BLDG-Associated Permit Residenli, Application Date: 12/13/2023 Owner: Work Class: Condo Issue Date: 04/23/2024 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 04/28/2025 Address: 2445 CALENDULA LN IVR Number: 5381 0 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status BLDG-SW-Inspection 258460-2024 Partial Pass Tony Alvarado Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 09/19/2024 09/19/2024 BLDG-Electric Meter 261492-2024 Passed Tony Alvarado Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 261624-2024 Partial Pass Tony Alvarado Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 10/29/2024 10/29/2024 BLDG-Final Inspection 266018-2024 Passed Tony Alvarado Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Monday, November 4, 2024 Page 5 of 6 PERMIT INSPECTION HISTORY for (CBRA2023-0223) Permit Type: BLDG-Associated Permit Residenti, Application Date: 12/13/2023 Owner: Work Class: Condo Issue Date: 04/23/2024 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 04/28/2025 Address: 2445 CALENDULA LN IVR Number: 53810 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 08/15/2024 08/15/2024 BLDG-84 Rough 257892-2024 Passed Tony Alvarado Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers BLDG-SW-Inspection 258118-2024 Partial Pass Tony Alvarado Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 08/19/2024 08/19/2024 BLDG-16 Insulation 258319-2024 Passed Tony Alvarado Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Monday, November 4, 2024 Page 4 of 6 PERMIT INSPECTION HISTORY for (CBRA2023-0223) Permit Type: BLDG-Associated Permit Residenti, Application Date: 12/13/2023 Owner: Work Class: Condo Issue Date: 04/23/2024 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 04/28/2025 Address: 2445 CALENDULA LN IVR Number: 53810 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 07/17/2024 07/17/2024 BLDG-15 Roof/ReRoof 255053-2024 Passed Chris Renfro Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 255134-2024 Partial Pass Chris Renfro Re inspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 08/06/2024 08/06/2024 BLDG-13 Shear 256996-2024 Passed Chris Renfro Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 257161-2024 Partial Pass Chris Renfro Reinspection Incomplete Monday, November 4, 2024 Page 3 of 6 PERMIT INSPECTION HISTORY for (CBRA2023-0223) Permit Type: BLDG-Associated Permit Residenti; Application Date: 12/13/2023 Owner: Work Class: Condo Issue Date: 04/23/2024 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 04/28/2025 Address: 2445 CALENDULA LN IVR Number: 53810 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 06/12/2024 06/12/2024 BLDG-14 251506-2024 Partial Pass Chris Renfro Reinspection Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd story deck nailing Yes BLDG-SW-Inspection 251637-2024 Partial Pass Chris Renfro Reinspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 06/25/2024 06/25/2024 BLDG-14 252885-2024 Partial Pass Chris Renfro Reinspection Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 3rd story deck nailing Yes BLDG-SW-Inspection 252989-2024 Partial Pass Chris Renfro Reinspection Incomplete Monday, November 4, 2024 Page 2 of 6 Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBRA2023-0223) Permit Type: BLDG-Associated Permit Residenti. Application Date: 12/13/2023 Owner: Work Class: Condo Issue Date: 04/23/2024 Subdivision: RANCHO AGUA HEDIONDA POR OF Status: Closed -Finaled Expiration Date: 04/28/2025 Address: 2445 CALENDULA LN IVR Number: 53810 CARLSBAD, CA 92008-3748 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 05/06/2024 05/06/2024 BLDG-21 247392-2024 Passed Chris Renfro Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 247501-2024 Partial Pass Chris Renfro Re inspection Incomplete Checklist Item COMMENTS Passed Are erosion control BMPs Yes functioning properly? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Has trash/debris accumulated Yes throughout the site? Are portable restrooms Yes properly positioned? Do portable restrooms have Yes secondary containment? 05/16/2024 05/16/2024 BLDG-11 248640-2024 Passed Chris Renfro Complete Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-31 248639-2024 Passed Chris Renfro Complete Underground/Conduit • Wiring Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 248762-2024 Partial Pass Chris Renfro Reinspection Incomplete Monday, November 4, 2024 Page 1 of 6 Structural AUG O 5 2024 BUILDING DIVISION KB Home -Coral Ridge at Maria Acres Townhomes Job#: 10-11634 Date of Observation: 08/05/2024 Structural Observation Requested by: Craig Stinger Structural Observation Report#6 Structural Obsenation performed by: Shawn Afshar, PE Date: 8/05/2024 Page: l of 6 /\rea Observed: BuildingFl3 (phase4) Lots 11-15 Framing Observed Structural Elements and their connections D Foundation D Floor Sheathing D Roof Sheathing l8I Exterior l8I Framing D Others D Footing & Slab D 2nd Floor l8I I" Level l8I I '1 Level D Holdown, Anchor D 3rd Floor l8I 2nd Level l8I 2nd Level bolts & associated D 4th Floor l8I 3'd Level l8I 3rd Level Rebar D 4'11 Level D 4th Level Status of Construction l8I Roof & Floor Trusses l8I Stair Installed l8I Bathtub lnstalled l8I Roof Sheathing D Window Installed l8I Preliminary Drywall Installed D Roof Loaded D Flashing I nstallcd l8I Drywall Stacked in Units l8I Second Floor wall □ Huilding Wrapped D Drywall on Wall l8I Third Floor Wall D Building Stuccoed D Drywall on Ceiling D Fourth Floor Wall l8I MEP installation on going l8I Sheathing one side Party Wall Pursuant to your request, a v isit to the project si te was made on the above date to perrorm a structural observation in conformance with CBC 2016 section 1702 and 1704.6. Please note, not all symmetric or repetitive areas were observed, therefore please have your field personnel verify the correction items in all similar areas. Where repair recommendations are given, veriry if additional coordination may be necessary with other trades or design proressionals. The structural observations do not constitute an approval of the work nor do they relieve the contractor or inspection agencies from complying with project and code requirements. All observations were conducted from the ground or floor level and no testing or inspection was perform ed. Our observations do not include a review of the contractors means or methods of construction, shoring, erection, bracing, nor any associated safety precautions. \ \ \ \ -T: (/14) 978-9780 IF: (714) 978-9788 j vIww.vcast1ucllir~l.com I 1845 W. Orangewood Ave., Ste. 200 I Orange, CA 92868 \