Loading...
HomeMy WebLinkAbout2715 GREENOCK CT; ; CBR2023-4959; PermitBuilding Permit Finaled Residential Permit Print Date: 12/04/2024 Job Address: 2715 GREENOCK CT, CARLSBAD, CA 92010-6515 Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: BLDG-Residential 2081123300 $4,672.62 Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check #: Plan Check #: Description: NOEL; RETAINING WALL PER CDRSD STANDARDS Applicant: STEVEN NOEL 1620 FARADAY AVE CARLSBAD, CA 92008-7313 (760) 535-784 7 FEE BUILDING PLAN CHECK Property Owner: STEVEN NOEL 1620 FARADAY AVE CARLSBAD, CA 92008-7313 (760) 535-7847 BUILDING PLAN REVIEW -MINOR PROJECTS (LOE) BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) RETAINING WALL-NON-ENGINEERED -CITY STANDARD SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -RESIDENTIAL (SMIP) SWPPP INSPECTION TIER 1 -Medium BLDG SWPPP PLAN REVIEW TIER 1 -Medium Retaining Wall Total Fees: $929.06 Total Payments To Date: $929.06 Permit No: Status: (city of Carlsbad CBR2023-4959 Closed -Finaled Applied: 11/08/2023 Issued: 12/26/2023 Finaled Close Out: 12/04/2024 Final Inspection: 12/02/2024 INSPECTOR: Alvarado, Tony Balance Due: AMOUNT $99.45 $197.00 $104.00 $153.00 $1.00 $0.61 $292.00 $82.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent lega l action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the st atute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov { City of RESIDENTIAL Plan Check C,6'(}.JJJ"ft> ..Lf7'5q BUILDING PERMIT Est. Value Carlsbad APPLICATION PC Deposit 8-1 \'\ D] 1'1-3 Date I Job Address 2715 Greenock Ct Unit: APN: 208-112-33 CT /Project #: Lot#: Year Built: 1982 BRIEF DESCRIPTION OF WORK: Retaining wall per CORSO Standards C-04 □ New SF : Living SF, ____ Deck SF, ___ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? O Y O N New Fireplace? O YON, if yes how many? ___ _ D Remodel: _____ SF of affected area Is the area a conversion or change of use? O Y O N □ Pool/Spa: ____ .SF Additional Gas or Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted:0Roof OGround, Tilt: 0 YON, RMA: 0 YO N, Battery:OYO N, Panel Upgrade: OY ON Electric Meter number: ___________ _ Other: Retaining wall per CORSO Standards C-04 APPLICANT (PRIMARY CONTACT) Name: Steven Noel Address: 2715 Greenock Ct City: Carlsbad State:_C_A __ .Zip: 92010 Phone: 760-535-7847 Email: steven .noel .architect@gmail.com DESIGN PROFESSIONAL Name: Steven Noel Address: 2715 Greenock Ct City: Carlsbad State:._c_A_-'Zip: 9201 o Phone: 760-535-7847 Email: steven.noel.architect@gmail.com PROPERTY OWNER Name: Steven Noel Address: 2715 Greenock Ct City: Carlsbad Phone: 760-535-7847 State: CA Zip:_9_20_1_0 __ _ Email: steven.noel.architect@gmail.com CONTRACTOR OF RECORD Business Name: ________________ _ Address: _________________ _ City:. _______ State:. ___ .Zip:. ______ _ Phone: __________________ _ Email: __________________ _ Architect State License: C29533 ------------CSLB License #: _______ Class: ______ _ Carlsbad Business License# (Required): _______ _ 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov REV. 04122 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaf firm under pena/tyof perjury that I am licensed under provisionsof Chapter 9 ( commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I a/so affirm under penalty of perjury one of the following declarations (CHOOSE ONE}: DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. PolicyNo •• _ --------------------------------------------- -OR- DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: -------------------------1 Polley No. ___________________________ Expiration Date: _______________ _ -OR- D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, Interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that t here is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: _______________________ _ CONTRACTOR CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation, Ali improvements existing on the property were completed in accordance with all regulations In existence at the time of their construction, unless otherwise noted. Note: If the person signing above is an authorized agent for the contract, NAME (PRINT): -"'"""."""--"'""".""""'"""."""-~~ SIGNATURE:. _________ DATE:. _____ _ ide a_le!ter of authorization on contractor letterhead. • t I • • -OR- (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided t hat such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale), -OR- (!]1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec, 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR- D I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: AND, D FORM 8-61 "Owner Builder Acknowledgement and Verification Form" Is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors,/ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http:/ /www.leginfo.ca.gov/calaw.html. OWNER CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildinss, structures, access roads, and utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan, Any potentially existing detail within these plans Inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; aciess roadslasements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accura ely shown nd labeled as well as all on-site srading/slte preparation. All Improvements existing on the property were completed in accordance with all regulations in exist~t~he time f thei~ co tructlon 11Dless alhc: IR!seMted. NAME (PRINT): _s_te_v_e_n_N_o_e_l ____ _ Note: lf_the person signing above is an authorized agent for !h_e pro1 SIGN:£µ ~ L.J I DATE: 11 .08.23 _owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 442-339-2719 Email: Building@carlsbadca.gov 2 REV. 04/22 PERMIT INSPECTION HISTORY for (CBR2023-4959) Permit Type: Work Class: Status: Scheduled Date BLDG-Residential Application Date: Retaining Wall Issue Date: Closed -Finaled Expiration Date: IVR Number: Actual Inspection Type Start Date Inspection No. Checklist Item Are inactives slopes properly stabilized? Are areas flatter than 3: 1 covered or protected? Are sediment controls properly maintained? Are erosion control BMPs functioning properly? Are natural areas protected from erosion? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Have materials collected around the storm drains? Has sediment accumulated on impervious surfaces? Are dumpsters and trash receptacles covered? Has trash/debris accumulated throughout the site? Are stockpiles and spoils protected from runoff? Are all storage areas clean and maintained? Were spills/leaks observed during the inspection? Were there any discharges during the inspection? Are BMPs stockpiled for emergency deployment? COMMENTS Wednesday, December 4, 2024 11/08/2023 12/26/2023 07/15/2024 53177 Inspection Status Owner: STEVEN NOEL Subdivision: CARLSBAD TCT#76-12 Address: 2715 GREENOCK CT CARLSBAD, CA 92010-6515 Primary Inspector Reinspection Inspection Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Page 7 of 7 PERMIT INSPECTION HISTORY for (CBR2023-4959) Permit Type: BLDG-Residential Work Class: Retaining Wall Status: Closed -Finaled Application Date: 11/08/2023 Issue Date: 12/26/2023 Expiration Date: 07/15/2024 IVR Number: 53177 Owner: STEVEN NOEL Subdivision: CARLSBAD TCT#76-12 Address: 2715 GREENOCK CT CARLSBAD, CA 92010-6515 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 12/02/2024 Checklist Item COMMENTS BLDG-Building Deficiency City Standard Retaining Wall-drainage system and SWPPPS and BMPS-ok. BLDG-SW-Inspection Checklist Item 236789-2024 COMMENTS Are inactives slopes properly stabilized? Are areas flatter than 3:1 covered or protected? Are sediment controls properly maintained? Are erosion control BMPs functioning properly? Are natural areas protected from erosion? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Have materials collected around the storm drains? Has sediment accumulated on impervious surfaces? Are dumpsters and trash receptacles covered? Has trash/debris accumulated throughout the site? Are stockpiles and spoils protected from runoff? Are all storage areas clean and maintained? Were spills/leaks observed during the inspection? Were there any discharges during the inspection? Are BMPs stockpiled for emergency deployment? 12/02/2024 BLDG-Final Inspection Checklist Item 269800-2024 COMMENTS BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Structural Final BLDG-SW-Inspection 269801-2024 Partial Pass Tony Alvarado Passed Tony Alvarado Passed Tony Alvarado Wednesday, December 4, 2024 Passed Yes Reinspection Incomplete Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Passed Yes Yes Yes Complete Complete Page 6 of 7 Permit Type: Work Class: Status: Scheduled Date 01/16/2024 PERMIT INSPECTION HISTORY for (CBR2023-4959) BLDG-Residential Application Date: 11/08/2023 Owner: STEVEN NOEL Retaining Wall Issue Date: 12/26/2023 Subdivision: CARLSBAD TCT#76-12 Closed -Finaled Expiration Date: 07/15/2024 Address: 2715 GREENOCK CT Actual Start Date 01/12/2024 IVR Number: 53177 CARLSBAD, CA 92010-6515 Inspection Type Inspection No. Inspection Primary Inspector Status Checklist Item COMMENTS Are inactives slopes properly stabilized? Are areas flatter than 3: 1 covered or protected? Are sediment controls properly maintained? Are erosion control BMPs functioning properly? Are natural areas protected from erosion? Are perimeter control BMPs maintained? Is the entrance stabilized to prevent tracking? Have sediments been tracked on to the street? Have materials collected around the storm drains? Has sediment accumulated on impervious surfaces? Are dumpsters and trash receptacles covered? Has trash/debris accumulated throughout the site? Are stockpiles and spoils protected from runoff? Are all storage areas clean and maintained? Were spills/leaks observed during the inspection? Were there any discharges during the inspection? Are BMPs stockpiled for emergency deployment? BLDG-11 236562-2024 Passed Tony Alvarado Foundation/Ftg/Piers (Rebar) Checklist Item BLDG-Building Deficiency COMMENTS January 12, 2024: pre-grout, City, standard retaining wall, approved detail, verified masonry, CMU block, wall clean cells with steel reinforcement -OK. BLDG-21 Underground/Underflo or Plumbing 236787-2024 Passed Tony Alvarado Reinspection Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Passed Yes Wednesday, December 4, 2024 Inspection Complete Complete Page 5 of 7 PERMIT INSPECTION HISTORY for (CBR2023-4959) Permit Type: BLDG-Residential Application Date: 11/08/2023 Owner: STEVEN NOEL Work Class: Retaining Wall Issue Date: 12/26/2023 Subdivision: CARLSBAD TCT#76-12 Status: Closed -Finaled Expiration Date: 07/15/2024 Address: 2715 GREENOCK CT IVR Number: 53177 CARLSBAD, CA 92010-6515 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are inactives slopes properly Yes stabilized? Are areas flatter than 3: 1 Yes covered or protected? Are sediment controls properly Yes maintained? Are erosion control BMPs Yes functioning properly? Are natural areas protected Yes from erosion? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Have materials collected Yes around the storm drains? Has sediment accumulated on Yes impervious surfaces? Are dumpsters and trash Yes receptacles covered? Has trash/debris accumulated Yes throughout the site? Are stockpiles and spoils Yes protected from runoff? Are all storage areas clean Yes and maintained? Were spills/leaks observed Yes during the inspection? Were there any discharges Yes during the inspection? Are BMPs stockpiled for Yes emergency deployment? 01/12/2024 01/15/2024 BLDG-66 Grout 236748-2024 Passed Tony Alvarado Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-SW-Inspection 236790-2024 Partial Pass Tony Alvarado Reinspection Incomplete Wednesday, December 4, 2024 Page 4 of 7 PERMIT INSPECTION HISTORY for (CBR2023-4959) Permit Type: BLDG-Residential Work Class: Retaining Wall Status: Closed -Finaled Application Date: 11/08/2023 Issue Date: 12/26/2023 Expiration Date: 07/15/2024 IVR Number: 53177 Owner: STEVEN NOEL Subdivision: CARLSBAD TCT#76-12 Address: 2715 GREENOCK CT CARLSBAD, CA 92010-6515 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency COMMENTS December 28, 2023 1. footing foundation/steel rebar, reinforcement, per city, standard, retaining wall with slope-backfill specifications, scope of work -approved. A) OK the poor cement/concrete 4500 psi per City LOE dept. and Geo-technical/soils engineer specifications. B) Informed owner builder contractor, representative Steve. 2. Final inspection will be reviewed for a second time on December 28, 2023 at 12:15 am. 3. SWPPPS soil erosion and sediment control devices -OK A) inform owner builder and masonry subcontractor. That soil sediment erosion needs to be cleaned up on sidewalk public right away areas. Including informed contractor representative no cleaning tools of any kind in gutter stormwater drain system. BLDG-12 Steel/Bond Beam 235222-2023 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS December 28, 2023 1. footing foundation/steel rebar, reinforcement, per city, standard, retaining wall with slope-backfill specifications, scope of work-approved. A) OK the poor cemenUconcrete 4500 psi per City LOE dept. and Geo-technical/soils engineer specifications. B) Informed owner builder contractor, representative Steve. 2. Final inspection will be reviewed for a second time on December 28, 2023 at 12:15 am. 3. SWPPPS soil erosion and sediment control devices -OK A) inform owner builder and masonry subcontractor. That soil sediment erosion needs to be cleaned up on sidewalk public right away areas. Including informed contractor representative no cleaning tools of any kind in gutter stormwater drain system. BLDG-SW-Inspection 235223-2023 Partial Pass Tony Alvarado Wednesday, December 4, 2024 Passed Yes Complete Passed Yes Reinspection Incomplete Page 3 of 7 PERMIT INSPECTION HISTORY for (CBR2023-4959) Permit Type: BLOG-Residential Application Date: 11/08/2023 Owner: STEVEN NOEL Work Class: Retaining Wall Issue Date: 12/26/2023 Subdivision: CARLSBAD TCT#76-12 Status: Closed -Finaled Expiration Date: 07/15/2024 Address: 2715 GREENOCK CT IVR Number: 53177 CARLSBAD, CA 92010-6515 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed Are inactives slopes properly Yes stabilized? Are areas flatter than 3: 1 Yes covered or protected? Are sediment controls properly Yes maintained? Are erosion control BMPs Yes functioning properly? Are natural areas protected Yes from erosion? Are perimeter control BMPs Yes maintained? Is the entrance stabilized to Yes prevent tracking? Have sediments been tracked Yes on to the street? Have materials collected Yes around the storm drains? Has sediment accumulated on Yes impervious surfaces? Are dumpsters and trash Yes receptacles covered? Has trash/debris accumulated Yes throughout the site? Are stockpiles and spoils Yes protected from runoff? Are all storage areas clean Yes and maintained? Were spills/leaks observed Yes during the inspection? Were there any discharges Yes during the inspection? Are BMPs stockpiled for Yes emergency deployment? 12/28/2023 12/28/2023 BLDG-11 235097-2023 Passed Tony Alvarado Complete Foundation/Ftg/Piers (Rebar) Wednesday, December 4, 2024 Page 2 of 7 Building Permit Inspection History Finaled {city of Carlsbad Permit Type: Work Class: Status: Scheduled Date 12/27/2023 PERMIT INSPECTION HISTORY for (CBR2023-4959) BLDG-Residential Retaining Wall Closed -Finaled Actual Inspection Type Start Date 12/27/2023 BLDG-11 Foundation/Ftg/Piers (Rebar) Checklist Item Application Date: 11/08/2023 Issue Date: 12/26/2023 Expiration Date: 07/15/2024 IVR Number: 53177 Inspection No. Inspection Status 234886-2023 Partial Pass COMMENTS Owner: STEVEN NOEL Subdivision: CARLSBAD TCT#76-12 Address: 2715 GREENOCK CT CARLSBAD, CA 92010-6515 Primary Inspector Reinspection Inspection Tony Alvarado Reinspection Incomplete Passed BLDG-Building Deficiency December 27, 2023 Yes BLDG-SW-Inspection 1. Partial pass -footing foundation, steel, reinforcement, city, standard, retaining wall with slope-backfill, scope of work per detail -not completely done. 2. Final inspection will be reviewed for a second time on December 28, 2023 at 10:30 AM. 3. SWPPPS soil erosion and sediment control devices -OK 235073-2023 Partial Pass Tony Alvarado Reinspection Incomplete Wednesday, December 4, 2024 Page 1 of 7 December 5, 2023 City of Carlsbad Community Development Department -Building Division 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review: Residential Retaining Wall Address: 2715 Greenock Ct Applicant Name: Steven Noel Applicant Email: steven.noel.architect@gmail.com OCCUPANCY AND BUILDING SUMMARY: Occupancy Groups: NI A Occupant Load: NI A Type of Construction: NIA Sprinklers: NI A Stories: NI A Area of Work (sq. ft.): NIA sq. ft. The plans have been reviewed for coordination with the permit application. Valuation: Confirmed Scope of Work: Confirmed Floor Area: Confirmed Attn: Building & Safety Department, True North COMPLIANCE SERVICES City of Carlsbad -FJNAL REVIEW City Penn it No: CBR2023-4959 True North No.: 23-018-1125 True North Compliance Services, Inc. has completed the final review of the following documents for the project referenced above on behalf of the City of Carlsbad: I. 2. Drawings: One (I) copy by Civil Landworks. Geotechnical Report: One (I) copy by CTE Inc. The 2022 California Building, Mechanical, Plumbing, and Electrical Codes (i.e., 2021 IBC, UMC, UPC, and 2020 NEC, as amended by the State of California), 2022 California Green Building Standards Code, 2022 California Existing Building Code, and 2022 California Energy Code, as applicable, were used as the basis of our review. Please note that our review has been completed and we have no further comments. We have enclosed the above noted documents bearing o ur review stamps for your use. Please call if you have any questions or if we can be of further assistance. S incerely, True North Compliance Services Review By: Bashir Habboub -Plan Review Engineer Quality Review By: Alaa Atassi -Plan Review Engineer True North Compliance Services, Inc. 8369 Vickers Street, Suite 207, San Diego, CA 92111 T / 562. 733.8030 A Universal C En~lneering Construction Testing & Engineering, Inc. CSciences Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying ompany November 13, 2023 Mr. Steve Noel 2715 Greenock Court Carlsbad, California 920 I 0 Telephone: (760) 535-7847 CTE/UES Job No. 10-15347G Via Email: Steve@2n5studio.com Subject: Proposed Noel Residence Retaining Wall Review and Update to Geotechnical Recommendations 2715 Greenock Court Carlsbad, California Mr. Noel: As requested, CTE/UES has completed the review of the referenced minor/standard retaining wall proposed at the subject site. Based on our review we provide this update to our previously prepared geotechnical letter/report. As implied, we understand thatthe project will now include a San Diego Regional Drawing Masonry Retaining Wall measuring less than six feet in retained height. As such, a geotechnical report is not generally considered necessary for the project. However, based on our review of the referenced plans, the plans are in accordance with appropriate geotechnical considerations for the site and have been signed and stamped by the undersigned for geotechnical purposes. In addition, from our geotechnical standpoint, the wall construction does not require structural inspection during construction; however, we recommend that CTE/UES review the wall foundation excavations to confirm appropriate conditions for concrete placement during construction. We appreciate the opportunity to be of service on this project. Should you have additional questions or comments, please do not hesitate to contact our office. Respectfully submitted, CONSTRUCTION TESTING & ENGINEERING, INC. Dan T. Math, GE #2665 Principal Engineer DTM:ach 1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 7 46-4955 I Fax (760) 7 46-9806 I www.cte-inc.net .. Proposed Noel Residence Retaining Wall Review and Update to Geotechnical Recommendations 2715 Greenock Court, Carlsbad, California November 13, 2023 Attachments: Lab Results (Two Sheets Total) Reference: Civil Plans 2751 Greenock Court, APN 208-112-33 Prepared by CivilLandworks, Dated November 7, 2023 Review of Wall Plan Proposed Noel Residence Retaining Wall 2715 Greenock Ct, Carlsbad, California CTE Job No. 10-15347G, February 14, 2020 Retaining Wall Recommendations Proposed Noel Residence Retaining Wall 2715 Greenock Court, Carlsbad, California CTE Job No. 10-15347G, Dated January 31, 2020 Page 2 CTE Job No. 10-15347G S:\Projects\10-15000 to 10.15999 Projects\10.153470\Ltr_Ret Wall Review and Update to Geo Doc.doc Construction Testing & Engineering, Inc. Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying January 31 , 2020 Mr. Steve Noel CTE Job No. 10-153470 2715 Greenock Court Carlsbad, California 920 I 0 Telephone: (760) 535-7847 Via Email: Steve.Noel@ROArchitecture.com Subject: Mr. Noel: Proposed Noel Residence Retaining Wall 2715 Greenock Court Carlsbad, California Construction Testing and Engineering, lnc. (CTE) has completed a geotechnical evaluap2n and is providing preliminary conclusions and recommendations for the proposed approximately~foot tall retaining wall at the above referenced site. Based on our evaluation, the proposed retaining wall will be suitable and stable for construction at the site, provided the design of the wall, by a qualified professional, utilizes the preliminary recommendations provided herein. 1.0 Site and Work Description The site consists of a previously graded building pad that supports an existing single-story, single- family residence. The previously graded building pad utilized an approximately 2: I (horizontal: vertical) slope to transition from the building pad to the street below. The proposed retaining wall will generally be used to replace the slope. 2.0 Laboratory Testing Laboratory tests were conducted on a selected soil samples for classification purposes, and to evaluate physical properties and engineering characteristics. Laboratory tests included: Modified Proctor and Remolded Direct Shear. The test results are attached herewith. 3.0 General CTE concludes that the proposed improvements on the site are feasible from a geotechnical standpoint, provided the preliminary recommendations in this report are incorporated into the design and construction of the project. Recommendations for the proposed earthwork and improvements are included in the following sections and Appendix D. However, recommendations in the text of this report supersede those presented in Appendix D should conflicts exist. These preliminary 1441 Montiel Road, Suite 115 I Escondido, CA92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net Proposed Noel Residence Retaining Wall 2715 Greenock Court Carlsbad, California January 31, 2020 Page 2 CTE Job No. 10-I5347G recommendations should either be confirmed as appropriate or updated following required excavations, demolition of existing improvements, and observations during site preparation. 3.1 Site Preparation Prior to grading, areas to receive distress sensitive improvements should be cleared of existing debris and deleterious materials. Objectionable materials, such as construction or demolition debris and vegetation not suitable for structural backfill should be properly disposed of off-site. We anticipate it will be suitable to excavate to the proposed wall foundation depths, wet down, and compact the surface of the exposed materials. As such, significant overexcavation is not anticipated. However, such conditions must be confirmed during construction. If loose or otherwise unsuitable materials are encountered at the base of overexcavations, additional excavation to the depth of suitable material may be necessary. A geotechnical representative from CTE should observe the exposed ground surface prior to placement of other compacted fill or improvements, to verify the competency of exposed subgrade materials. After approval by this office, the exposed subgrades, where or if they are to receive fill, should be scarified a minimum of eight inches, moisture conditioned, and properly compacted prior to fill placement. 3.2 Site Excavation Based on CTE's observations, shallow excavations at the site should generally be feasible using well-maintained heavy-duty construction equipment run by experienced operators. 3.3 Fill Placement and Compaction Areas to receive fills or backfill should be scarified approximately eight inches, moisture conditioned, and properly compacted. Fill and backfill should be compacted to a minimum relative compaction of 90 percent at above optimum moisture content, as evaluated by ASTM D I 557. The optimum lift thickness for fill soil depends on the type of compaction equipment used. Generally, backfill should be placed in uniform, horizontal lifts not exceeding eight inches in loose thickness. Fill placement and compaction should be conducted in conformance with local ordinances, and should be observed and tested by a CTE geotechnical representative. \\ESC_SERVER\Projects\l 0-15347G\Ltr_Ret Wall Recs.doc Proposed Noel Residence Retaining Wall 2715 Greenock Court Carlsbad, California Page 3 January 31 , 2020 CTE Job No. 1 0-l 5347G 3.4 Fill Materials Properly moisture conditioned very low to low expansion potential soils derived from the on-site materials are considered suitable for reuse on the site as compacted fill. If used, these materials should be screened of organics and materials generally greater than three inches in maximum dimension. Irreducible materials greater than three inches in maximum dimension should not be generally used in shallow fills (within three feet of proposed grades). Imported fill beneath structures and flatwork should have an Expansion Index of20 or less (ASTM D 4829). Imported fill soils for use in structural or slope areas should be evaluated by the soils engineer a minimum of two weeks before being imported to the site. 3.5 Temporary Construction Slopes The following recommended slopes should be relatively stable against deep-seated failure, but may experience localized sloughing. On-site soils are considered Type B soils with a recommended maximum slope ratio of 1: l. Actual field conditions and soil type designations must be verified by a "competent person" while excavations exist, according to Cal-OSHA regulations. In addition, the above sloping recommendations do not allow for surcharge loading at the top of slopes by vehicular traffic, equipment or materials. Appropriate surcharge setbacks must be maintained from the top of all unshared slopes. 3.6 Preliminary Retaining Wall Design Recommendations The following recommendations are for preliminary design purposes only. I. Allowable footing bearing pressure, at minimum depth of 12 inches below lowest adjacent subgrade elevation: 3,000 psf, plus an additional 250 psf for each additional six inches of embedment up to a maximum value of 3,500 psf. 2. Footings should have a minimum 7.5 feet distance to daylight from adjacent descending slopes. 3. Passive Soi I Pressure: 300 psf per foot of depth, with a maximum value of 3,000 psf. 4. Coefficient of Soil Friction: 0.30 5. Active and At-Rest (if needed) soil pressures should be as shown in Table 3.6. 6. If needed, a design seismic coefficient of 0.33 can be used for simple wall design. 7. The structural engineer should provide all footing and wall detailing and specifications. 8. A typical but adequate backdrain system should be installed for walls, as necessary and per the structural engineer or architect. \\ESC _ S ERVER\Projects\l 0-1534 7G\Ltr _ Ret Wall Recs.doc Proposed Noel Residence Retaining Wall 2715 Greenock Court Carlsbad, California January 31 , 2020 Page 4 CTE Job No. I 0-153470 TABLE3.6 EQUlV ALENT FLUlD UNIT WEIGHTS (Gh) (pounds per cubic foot) SLOPE BACKFILL WALL TYPE LEVEL BACKFILL 2: I (HORlZONTAL: VERTICAL) CANTlLEVER WALL 35 55 (YIELDING) RESTRArNED WALL 55 65 3.7 Seismic Design Criteria The seismic ground motion values listed in the table below were derived in accordance with the ASCE 7-16 Standard. This was accomplished by establishing the Site Class based on the soil properties at the site. Site coefficients and parameters were calculated using the U.S. Seismic Design Maps application. These values are intended for the design of structures to resist the effects of earthquake ground motions for the site coordinates 33.15960639° latitude and -117.30118606° longitude, as underlain by soils corresponding to site Class C. \\ESC_SERVER\Projects\10-15347G\Ltr_Ret Wall Recs.doc Proposed Noel Residence Retaining Wall 2715 Greenock Court Carlsbad, California January 31 , 2020 Page 5 CTE Job No. 10-15347G TABLE3.7 SEISMIC GROUND MOTION VALUES (CODE-BASED) 2019 CBC AND ASCE 7-16 PARAMETER VALUE 2019 CBC/ASCE 7-16 REFERENCE Site Class C ASCE 16, Chapter 20 Mapped Spectral Response 1.076 Figure 1613.2.1 (I) Acceleration Parameter, Ss Mapped Spectral Response 0.415 Figure 16 13.2.1 (2) Acceleration Parameter, S 1 Seismic Coefficient, Fa l Table 16 13.2.3 (l) Seismic Coefficient, Fv 1.385 Table 1613.2.3 (2) MCE Spectral Response 1.076 Section 1613.2.3 Acceleration Parameter, SMs MCE Spectral Response 0.575 Section I 6 I 3.2.3 Acceleration Parameter, SM1 Design Spectral Response 0.717 Section 1613.2.5(1) Acceleration, Parameter Sos Design Spectral Response 0.383 Section 1613.2.5 (2) Acceleration, Parameter Soi Peak Ground Acceleration 0.415 ASCE 16, Section 11.8.3 PGAM 3.8 Seismic Design The more detailed seismic design is required, the following can be used. Lateral pressures on cantilever retaining walls (yielding walls) over six feet high due to earthquake motions may be calculated based on work by Seed and Whitman ( 1970). The total lateral earth pressure against a properly drained and backfi lied cantilever retaining wall above the groundwater level can be expressed as: For non-yielding (or "restrained") walls, the total lateral earth pressure may be similarly calculated based on work by Wood (1973): Where P Alb = Static Active Earth Pressure = GhH2/2 \\ESC_SERVER\Projects\10-15347G\Ltr_Ret Wall Recs.doc Proposed Noel Residence Retaining Wall 2715 Greenock Court Carlsbad, California January 31, 2020 PK/b = Static Restrained Wall Earth Pressure = GhH2/2 ~p Ad b = Dynamic Active Earth Pressure Increment = (3/8) kh yH2 ~Pw b = Dynamic Restrained Earth Pressure Increment = kh yH2 b = unit length of wall (usually I foot) k11 = I /2* PGAm (PGAm given previously Table 6.8) Gh = Equivalent Fluid Unit Weight (given previously Table 6.9) H = Total Height of the retained soil y = Total Unit Weight of Soil ::::: 135 pounds per cubic foot Page 6 CTE Job No. I O-l 5347G *It is anticipated that the 1/2 reduction factor will be appropriate for proposed walls that are not substantially sensitive to movement during the design seismic event. Proposed walls that are more sensitive to such movement could utilize a 2/3 reduction factor. If any proposed walls require minimal to no movement during the design seismic event, no reduction factor to the peak ground acceleration should be used. The project structural engineer of record should determine the appropriate reduction factor to use (if any) based on the specific proposed wall characteristics. The static and increment of dynamic earth pressure in both cases may be applied with a line of action located at H/3 above the bottom of the wall (SEAOC, 2013). These values assume non-expansive backfill and free-draining conditions. Measures should be taken to prevent moisture buildup behind all retaining walls. Drainage measures should include free- draining backfill materials and sloped, perforated drains. These drains should discharge to an appropriate off-site location. Waterproofing should be as specified by the project architect. 3.9 Drainage Surface runoff should be collected and directed away from improvements by means of appropriate erosion-reducing devices and positive drainage should be established around the proposed improvements. Positive drainage should be directed away from improvements at a gradient of at least two percent for a distance of at least five feet. However, the project civil engineers should evaluate the on-site drainage and make necessary provisions to keep surface water from affecting the site. Generally, CTE recommends against allowing water to infiltrate building pads or adjacent to slopes. CTE understands that some agencies are encouraging the use of storm-water cleansing devices. Use of such devices tends to increase the possibility of adverse effects associated with high groundwater including slope instability. \\ESC_SERVER\Projects\10-15347G\Ltr_Ret Wall Recs.doc Proposed Noel Residence Retaining Wall 2715 Greenock Court Carlsbad, California January 31 , 2020 3.10 Slopes Page 7 CTE Job No. 10-15347G Based on anticipated soil strength characteristics slopes, if proposed, should be constructed at ratios of 2: I (horizontal: vertical) or flatter. These slope inclinations should exhibit factors of safety greater than 1.5. Although properly constructed slopes on this site should be grossly stable, the soils will be somewhat erodible. Therefore, runoff water should not be permitted to drain over the edges of slopes unless that water is confined to properly designed and constructed drainage facilities. Erosion-resistant vegetation should be maintained on the face of all slopes. Typically, soils along the top portion of a fill slope face will creep laterally. CTE recommends against building distress-sensitive hardscape improvements within five feet of slope crests, and against using thickened edges in this area. We appreciate the opportunity to be of service on this project. Should you have additional questions or comments, please do not hesitate to contact our office. Respectfully submitted, CONSTRUCTION TESTING & ENGINEERING, INC. Dan T. Math, GE #2665 Principal Engineer DTM:ack Attachments: Lab Results (Two Sheets Total) \\ESC_SERVER\Projects\10-1 5347G\Ltr_Ret Wall Recs.doc LABORATORY COMPACTION OF SOIL (MOD.) ASTM D 1557 Project Name: Steve Noel Res Project No.: 10-15347G Lab No.: 30298 Tested By : __ J_H __ Calculated By : JH ----Sampled By: __ D_M __ Date: 12/20/2019 Date: 12/20/2019 Date: 12/12/2019 Sample Location: _N_/A _____________ _ Depth (ft.) __ N_/A __ Sample Description: Dark Brown SM ---------------------------------- Moisture Added (ml) lt:~I NU. Wt. Comp. Soil+ Mold (a) Wt. of Mold (Q) Net Wt. of Soil la) Wet Wt. of Soil+ Cont. (a) Ory Wt. of Soil + Cont. (g) Wt. of Container (g) Moisture Content(%) Wet Density (pcf) Orv Density (ocO I ___ P_R__,OCEDURE USED X I Procedure A Soil Passing No. 4 (4.75 mm) Sieve Mold : 4 in. (101.6 mm) diameter Layers : 5 (Five) Blows per layer : 25 (twenty-five) May be used if No.4 retained =/< 25% I ___ _,I Procedure B Soil Passing 3/8 in. (9.5 mm) Sieve Mold : 4 in. (101.6 mm) diameter Layers : 5 (Five) Blows per layer: 25 (twenty-five) May be used if 3/8" retained =/< 25% I Procedure C 11----_, Soil Passing 3/4 In. (19.0 mm) Sieve Mold : 6 in. (152.4 mm) diameter Layers : 5 (Five) Blows per layer : 56 (fifty-six) May be used if 3/4" retained =/< 30% 0 1 3936 2001 1936 220.5 200.5 0.0 10.0 128.1 116.5 130.0 125.0 i:-·;;; 120.0 C: ~ ~ 0 115.0 110.0 00 50 2 4019 2001 2019 212.5 189.5 0.0 12.1 133.6 119.2 Weight Retained (g) Percent Retained 0.0 Plus 3/4" 11---------' '---------fl 0.0 Plus 3/8" 11---------' L....-------1 185 Plus #4 1.3 100 3 4034 2001 2034 216.0 189.5 0.0 14.0 134.6 118.1 50 150 4 3996 2001 1996 222.0 191.5 0.0 15.9 132.1 114.0 \ \ ' ' \ I\ ' \ y / I 10.0 Preparation Method: Ory CKJ Moistc=J Mechanical RammerCKJ Manual Rammerc::J Hammer Weight:! 10.0 lb. Drop:! 18 In. Mold Volume (ft.3):! 0.03330 \ -SP. GR.= 2.65 .)c-v-V SP. GR.= 2.70 SP. GR.= 2.75 IY -1--"" \ \ \ \ \ ' \ I\ I\' \ \ I\ I\ \ \ ... \ I\, _="i ' \ I\ I', \ I\ \ ' ' \ I\ \ I\ \ \ \ \ \ \ \ \ \. \. I\\ \ \\ 15.0 20.0 Moisture Content (%) Maximum Dry Density (pcf) Optimum Moisture Content (%) 119.2 12.5 Rock Correction Applied per ASTM D 4718 Maximum Dry Density (pcf) N/A Optimum Moisture Content (%) N/A Proctor 30298 PRE CONSOLIDATION SHEARING DATA 0.025 5000 --0.026 ----\ --4000 0.027 ' I"' C' Ill I U) 0,028 S: G> \ 1/) 3000 .c 1/) ' ,., ~ 0.029 w i--~~ ~ « i--I-' .,-z 1/) _/ ~ 0.030 « 2000 ~ c( , I-0,031 w II) :c ......... .... II) ""'· 1000 ~ 0032 V" r--,, .... y 0.033 0 0034 0 2 4 6 8 10 12 14 16 18 20 0.1 1 10 100 __ 1000ps;I STRAIN(%) TIME (minutes) VERTICAL --3000psf STRESS -5000psf FAILURE ENVELOPE 5000 ,, 4000 c;::- ! 1/) 3000 II) ,, w « I-1/) (!) z ii: c( w 2000 :c II) 1000 0 d,-0.l200mm}min I ~ 0 CT~c 0 1000 2000 3000 4000 5000 VERTICAL STRESS (psf) SHEAR STRENGTH TEST -ASTM D3080 Job Name: Steve Nole Residence Initial Dry Density (pct): 107.3 Project Number: 10-1 53470 Sample Date: 12/12/2019 Initial Moisture(%): 12.5 Lab Number: 30298 Test Date: 12/23/2019 Final Moisture (%): 19.0 Sample Location: NIA Tested by: KF Cohesion: 180 psf Sample Description: Gralish Brown SM Angle Of Friction: 42.3