HomeMy WebLinkAboutPRE 2024-0065; MULTI-FAMILY RESIDENTIAL DEVELOPMENT; Admin Decision Letter{'cicyof
Carlsbad
January 22, 2025
ATIEH KAENI
SUBTRAKT STUDIO
119 E. AVENI DA SAN JUAN
SAN CLEMENTE, CA 92672-3232
SUBJECT: PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
APNs 203-172-03-00
Dear Mr. Kaeni,
Thank you for submitting a preliminary review application for the demolition of an existing single-family
home and the construction of a seven-unit, three-story multi-family residential development with one
level of underground parking at 367 Beech Avenue (Assessor Parcel Numbers 203-172-03-00). The 0.19-
acre project site is developed with a one-story single-family home.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning Division Comments:
General
1.
2.
The current General Plan and zoning designations for the properties are as follows:
a. General Plan: Village-Barrio (V-B)
b. Zoning: Village-Barrio (V-B)
c. Master Plan: The project is located within the Village Center (VC) District of the Village and
Barrio Master Plan (VBMP). The permitted density.is 28 to 35 dwelling units per acre.
d. . Coastal Zone: The project site is located within the boundaries of the Coastal Zone and
outside the appealable jurisdiction.
Required Permits. The following permits will be required:
a. Site Development Plan. Pursuant to VBMP Section 6.3.3(8), an SDP is required for new
construction of 5 or more residential units.
b. Tentative Tract Map. If the units will be for sale (i.e., condominiums instead of apartments),
a tentative tract map will be required.
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 2
3.
4.
5.
6.
c. Coastal Development Permit. Pursuant to VBMP Section 6.3.4(8) and (C), the Planning
Commission will make a recommendation to the City Council. The City Council is the final
decision-making authority for coastal development permits. As City Council approval is
required for the CDP, the Minor SDP (and CT, if applicable) will also be considered by the
City Council.
The Housing Crisis Act of 2019 (SB 330) established a preliminary streamline application process
for housing projects. It is not mandatory unless applicants seek the vesting and processing
benefits offered under SB 330. Participation in the SB 330 streamline process would occur first,
followed by the formal development application process required under Government Code (Gov.
Code)§§ 65940, 65941, 65941.5, and Carlsbad Municipal Code (CMC) § 21.42.050. Acceptance by
the city of a complete SB 330 Streamline Application (Form P-32) and fee will vest the project for
180 days in accordance with the ordinances, policies and standards in .effect at the time the SB
330 Application is accepted.
Protected Units. Per the Housing Crisis Act of 2019 (SB 330), any project that includes the removal
or demolition of a "protected unit" is required to provide the occupants with 1) relocation benefits
(Gov. Code§ 7260 et seq .), and 2) right of first refusal for a comparable unit available in the new
housing development. (Gov. Code § 66300 (d)(2)(D).) "Protected units" are generally defined by
Gov. Code § 66300(d)(2)(E)(ii) as including residential units subject to affordability restrictions,
price controls, or occupied by low income households. The formal submittal of the project will
need to include documentation regarding any existing "protected units.". Please see link to
Housing Declarations, Form P-38, below.
https://www.carlsbadca.gov/home/showpublisheddocument/13862/638207099023970000
Land Use. Pursuant to Table 2-1 of the VBMP, multiple-family dwellings are permitted uses.
However, pursuant to Figure 2-2 of the VBMP, the subject parcel is in a use restriction area of the
VC District. Specifically, residential uses cannot be located on the ground floor and commercial
space shall occupy more than one-half of the habitable space on the ground floor and shall span
at least 80 percent of the building frontage. The conceptual project, which does not include
commercial area on the ground floor, does not comply.
Density. The density range for the VC district is 28-35 dwelling units per acre.
Units permitted for 0.19-acre parcel:
5 or 6 dwelling units (exclusive of a density bonus request):
Minimum density = 28 du/ac:
Minium unit yield = 28 x 0.19 = 5.32; rounds down to 5 units
(can round down per Carlsbad Municipal Code Section 21.53.230, Table A)
Maximum density= 35 du/ac:
Maximum unit yield = 35 x 0.19 = 6.65; rounds down to 6 units
(required to round down per Carlsbad Municipal Code Section 21.53.230, Table A)
Conceptual project:
The conceptual proposal to construct 7 multi-family units exceeds the maximum allowable
residential density. A density bonus will be required. Please see link to Informational Bulletin, IB
112, for additional information regarding density bonus projects.
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 3
7.
https://www.carlsbadca.gov/home/showpublisheddocument/8169/638600078695630000
lnclusionary Housing Requirement. Pursuant to CMC Chapter 21 .85, lnclusionary Housing
Ordinance, and Informational Bulletin IB-157, all residential developments proposing 7 or more
housing units are required to provide at least 15% of the total number of units (including density
bonus units) to be restricted for low-income households. Based on the proposal to construct 7
units, one inclusionary housing unit shall be provided onsite. Due to the conceptual nature of the
project, the project was not reviewed by the Housing & Homeless Services Department.
Please see link to IB-157 below for additional information regarding the inclusionary housing
requirements.
https://www.carlsbadca .gov/home/showpublisheddocument/9634/637897580094270000
Please note, if the project is redesigned to provide 6 units, an inclusionary unit will not be
required. Instead, an in-lieu inclusionary housing fee will be required. The current fee is $15 per
square foot of net building area for each market rate .unit.
8. VBMP Objective Design Standards (ODS). In addition to the standards contained in the VBMP, the
proposed multi-family project will likely be required to comply with the ODS for the VBMP. The
ODS standards for projects in the Coastal Zone are anticipated to be approved by the Coastal
Commission in May 2025. Please note that there are architectural styles associated with the
various subdistricts that will need to be identified and the proposed designed adhered to. Please
review your design against the ODS and revise where any non-compliance might occur. Please
see links below for reference and apply the standards to the final design, as applicable. Please
inc.lude a detailed compliance analysis with the project submittal.
9.
VBMP ODS:
https://www.carlsbadca.gov/home/showpublisheddocument/13754/638312276242470000
IB 302, Objective Design Standards:
https://www.carlsbadca .gov/home/showpublisheddocument/18333/638603458786370000
Parking/AB 2097. Assembly Bill 2097 (AB 2097), effective January 1, 2023, which added
Government Code §65863.2, effectively eliminated parking requirements in new residential and
commercial developments when located within a half mile of a major transit stop. The project is
within one-half mile of Carlsbad Village Train Station and therefore the project qualifies for AB
2097. The intent of AB 2097 is to provide flexibility for project design, concurrent with planning
studies that have shown that parking should be market driven. Developers could still voluntarily
provide onsite parking, but the number of parking spaces provided will be based on builder
preference and market demand, not by city-established minimum parking standards. For
additional information on AB 2097, please see the City of Carlsbad Information Bulletin, IB-131,
located at the following link:
https://www.carlsbadca.gov/home/showpublisheddocument/12218/638083521809200
000
Irrespective of proximity to public transit, state law allows the city to continue to apply minimum
parking standards for electric vehicle (EV) charging stations as well as required parking spaces
accessible to persons with disabilities (ADA). Please determine the number of required EV capable
Community Deve lopment Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 4
spaces and EV charging stations, accessible spaces and accessible EV charging stations required
pursuant to CMC 18.21.040, and the California Building Code Title 24 Part 2. Show, dimension and
label the location of these spaces on the plans to show compliance. Please note, EV and ADA
spaces required for retail spaces must be made available to the retail spaces.
Parking dimension in a parking structure. If a parking structure is proposed, pursuant to CMC
Section 21.44.060, Table D, the minimum dimension for parking stalls in a parking garage are 8.5
feet x 20 feet, exclusive of supporting columns/posts. In addition, a back-up distance of 24 feet
and 5-foot turning bump-out is required at the end of a stall series (i.e., dead end). Please also
ensure an area is striped for "No Parking" to allow room for cars to pull-into and safely back-up
and turn-around . With the project submittal, please demonstrate compliance with these
standards.
10. Setbacks. The project shall be designed to comply with the following setbacks.
Front: Minimum of O feet, maximum of 5 feet to building (at the ground floor). Additional depth
permitted where area includes a plaza, courtyard, or outdoor dining. Additional depth is also
permitted to accommodate electrical transformers, utility connections, meter pedestals, and
similar equipment only if other locations are infeasible as determined by the decision-maker.
Side: O feet
Rear: O feet
11. Open Space. A minimum of 60 square feet of private open space per residential unit shall be
provided with a minimum dimension of 6 feet in any direction. As less than 11 units are proposed,
there is no requirement for common open space.
12. Lot Coverage: There is no minimum or maximum lot coverage in the VC district.
13. Building Height. The maximum allowable building height in the VC district is 45 feet and four
stories. If ground floor commercial is included in the design (which is required), the minimum
ground floor plate height shall be 14 feet.
If a 4-Story building is proposed:
a. A maximum of 30 percent of the fourth story street facing fa~ade can have a O foot setback
(as measured from the property line). The remaining 70 percent shall be set back a minimum
of 10 feet (as measured from the property line).
b. The total square footage of enclosed fourth floor space shall not exceed 80 percent of the
largest enclosed floor space below (floors one, two, or three). However, in no case shall the
fourth floor enclosed space exceed the amount of third floor enclosed space.
14. The following technical studies/reports, beyond those listed as required in Development Permit
Application Form P-2, shall be required with a formal submittal. Each of the studies/reports shall
be provided in hardcopy (2 copies each) and digital (.pdf):
a. Air Quality Analysis.
b. Historical, Cultural and Paleontological (3 separate reports). The development of the
proposed project will require demolition of an older single-family home and excavation in an
Community Deve lopment Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 5
area of the city known to have a high sensitivity as it relates to (1) architectural history, (2)
archeological resources, and (3) paleontological resources. Please direct your consultant to
the city's Tribal, Cultural and Paleontological Resources Guidelines. Please note that any
archeological pedestrian survey of the site for the cultural resources study shall also include
a Native American monitor during the survey. The city's Tribal, Cultural and Paleontological
Resources Guidelines may be found on the city's website at:
https://www.carlsbadca .gov/home/showpublisheddocument/254/637425976516870000
c. Noise Study: A noise study shall be submitted for any residential project requiring a
discretionary permit containing five or more dwelling units or any multiple-family dwelling
units located within or 500-feet beyond the 60 dB(A) CNEL noise contour line of the Noise
Contour Map as part of the Carlsbad General Plan . This project meets both of the above
qualifications, in that the multiple-family project is proposing 17 dwelling units and the
property is approximately 266 feet beyond the 60 dB(A) CNEL contour line. Please provide a
noise study in compliance with the City of Carlsbad Noise Guidelines. The city's Noise
Guidelines Manual may be found on the city's website at:
https:ljwww.carlsbadca.gov/home/showpublisheddocument/238/637425974092370000
The City's General Plan Noise Element (Chapter 5) may be found on the city's website at:
https://www.carlsbadca.gov/home/showpublisheddocument/3426/637434861102600000
This does not represent an exhaustive list. Additional Planning-related studies may be required .
In addition, there may be other studies requested by the reviewing City Departments and
Divisions listed below.
15. As it relates to both the site and building design, please see Village & Barrio Master Plan (VBMP),
section 2.7.1 (I) on pg . 2-40 as it relates Ground Floor Street Frontage Uses:
New ground floor street frontage uses permitted within the boundaries of the use
restriction area identified on Figure 2-2 shall occupy more than one-half of the habitable
space developed on the ground floor and shall span at least 80 percent of the building
frontage. (VBMP, Section 2.7.1 (1)(1)).
Up to 20 percent of a building frontage may be used for a lobby or entryway to uses above
or behind ground floor street frontage uses. (VBMP, Section 2.7.1 (1)(2)).
16. This preliminary review application did not include a preliminary landscape exhibit(s); and thus, it
was not routed for landscape review. Please note with a formal application submittal, conceptual
landscape exhibits are required and shall be prepared in accordance with the General
Requirements listed in Section 3 of the City of Carlsbad Landscape Manual (February 2016). The
exhibit package shall include a Conceptual Landscape Plan; Conceptual Water Conservation Plan;
Conceptual Fire Protection Plan; and a Conceptual Landscape Maintenance Responsibility Exhibit
(private or common). The Landscape Manual may be found on the city's website at:
https://www.carlsbadca .gov/home/showpublisheddocument/234/637425974086270000
Commun ity Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 6
17. Due to the conceptual nature of the proposal, no detailed comments were provided on the site
plan. Please refer to the link below for details on what should be included on the site plan
submitted with a formal development application.
Development Permits, P-2:
https://www.carlsbadca.gov/home/showpublisheddocument/16155/638475754241670000
18. Early Public Notice and Stakeholder Outreach. The project is subject to City Council Policy
Statement No. 84, Development Project Public Involvement. Please review policy 84, as early
public noticing and stakeholder outreach requirements have recently been updated.
An early public notice is required to be prepared by the applicant and mailed to all owners and a
notice sign is required to be posted onsite by the applicant within 30 days of the application
submittal date. In addition, the applicant is required to complete enhanced stakeholder outreach
to further engage the community on their project. Project applicants shall conduct at least one in-
person public outreach meeting with the community. Additional meetings are encouraged and
recommended but not required.
The Draft Development Project Public Involvement Package must be submitted at the time of the
application submittal. Applicants are encouraged to begin engaging and soliciting public input
prior to application submittal, however outreach conducted prior to submittal does not satisfy
the requirements of the policy.
19. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely
impact development requirements of this project. A formal application submittal will need to
include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements
will apply to the project. New GHG reduction requirements are related to energy efficiency,
photovoltaic, electric vehicle charging, water heating and traffic demand management
requirements, as set forth in the California Green Building Standards Code and in Carlsbad
Municipal Code Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the
following address:
http://www.qcode.us/codes/carlsbad/view.php?topic=18&frames=on
To the extent that new GHG reduction requirements are in effect at the time of application for
grading or building permits, the project will be required to comply with the effective requirements
even if different than what is proposed in the project's planning approvals. GHG reduction
requirements may impact, but are not limited to, site design and local building code requirements.
If incorporating new GHG reduction requirements results in substantial modifications to the
project after planning approvals are obtained, then prior to issuance of grading or building
permits, the applicant may be required to submit and receive approval of a Consistency
Determination or an Amendment application for the project through the Planning Division.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-development/planning. You may also access the
General Plan Land Use Element and the Zoning Ordinance online at the website address shown . Please
review all information carefully before submitting.
land Development Engineering Division Comments, Jose Sanchez, jose.sanchez@carlsbadca.gov
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442 -339-2600
PRE 2024-0065 (DEV2024-0135}-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 7
1. Contact Nick Gorman in the Transportation Division at Nick.Gorman@carlsbadca.gov, a division
of the Public Works Department, to determine if a Scoping Agreement is required. Scoping
Agreements are used to determine if a Local Mobility Analysis (LMA} is required and the scope of
analysis. If an LMA is deemed necessary, first, work with Transportation Division staff to obtain
an approved scoping agreement. After the scoping agreement has been approved, submit the
approved Scoping Agreement as an appendix within the LMA that is to be prepared per the most
recent Transportation Impact Analysis Guidelines.
2. After the scoping agreement has been approved or deemed not necessary by the Transportation
Division, submit a completed Transportation Analysis Need Statement Form P-42 to Land
Development Engineering at LandDev@carlsbadca.gov prior to discretionary application
submittal. If an LMA has been deemed not necessary by the Transportation Division, please
provide correspondence from the Transportation Division indicating one is not required.
3. Depending on the CEQA determination, which is determined after the application for
discretionary permits is submitted, a Vehicle Miles Traveled (VMT} analysis may be required per
the Vehicles Miles Traveled Analysis Guidelines available at:
https ://www .ca rlsbadca .gov /home/ showdocume nt?id=312.
4. Complete a Stormwater Standards Questionnaire Form E-34. This questionnaire will guide you
and the city in determining what type of reports and storm water mitigation must be completed
to satisfy state and City storm water quality requirements. The questionnaire is located on the
City of Carlsbad website.
5. Based on a preliminary analysis it appears that this project will be a Standard Project. Complete
the Standard Project Requirement Checklist, Form E-36, and show all source and site design BMPs
on the conceptual grading and drainage plans.
6. Based on this project's general land use Village-Barrio, this project is subject to the City of Carlsbad
trash capture requirements. Incorporate trash capture measures on the project plans. PREPARE
A PRELIMINARY TRASH CAPTURE STORM WATER QUALITY MANAGEMENT PLAN, Form E-35A.
7. Provide a Preliminary Title Report (current within the last six (6) months).
8. Annotate and delineate all existing easements and encumbrances listed in the Preliminary Title
Report on the site plan. If any vacations · or quitclaims are planned with this development
annotate on the site plan.
9. A preliminary geotechnical report is required to evaluate the feasibility of the project. Guidelines
for preliminary geotechnical studies are available on the City of Carlsbad Engineering website.
10. Per CMC15 .16.060 this project will require a grading permit and grading plan.
11. A separate improvement plan for work within the right-of-way maybe required for this project.
12. This project shall utilize City of Carlsbad Survey Control Network established on Record of Survey
Map 17271, NAD83, Zone VI, 1991.35 Epoch for horizontal control and NGVD 29 datum for vertical
control per City of Carlsbad Engineering Standards.
Community Deve lopment Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 8
13. Delineate and annotate the limits of grading. Include remedial grading quantities on the plan.
14. Delineate and annotate approximate topographic contours for existing and proposed condition.
Provide 1-foot contours for slopes less than 5%; 2' intervals for slopes between 5% and 10%, and
5' intervals for slopes over 10%. Extend contours a minimum 25 feet beyond the project
boundary.
15. On the site plan, show and identify all existing surface improvements screened back (curb, gutter,
sidewalk, paving, manholes, inlets, streetlights, adjacent driveways, vaults, transformers, etc.) at
the project site, project frontage and within 25 feet of the boundary.
16. Indicate the earthwork quantities (cut, fill, import, export, remedial) proposed for the project in
cubic yards .
17. Provide spot elevations at the corners of each pad in the proposed condition. Include finish pad
and floor elevations.
18. Provide the method of draining. Unless otherwise specified by a geotechnical engineer, method
of drainage shall comply with California Building Code (latest version) section 1804.4.
19. Delineate all retaining walls that will be utilized on the project site and show top of wall and
bottom of wall elevations, including at the highest and lowest points. Indicate maximum height
of retaining wall measured from bottom of footing to top of wall and maximum height measured
from finish surface to top of wall.
20. Provide a cross section to show the existing and proposed ground, the proposed wall, the footing
and remedial excavation. Provide a temporary construction easement or permission to grade
letter from adjacent owner to construct walls on their property or delineate and annotate
proposed temporary shoring walls.
21. Delineate location of all existing and proposed buildings, walls, fences and permanent structures
onsite and within 25 feet of the site.
22. The project frontage has been identified in the city's inventory as a vacant planting site.
Coordinate with the parks and recreation department for planting requirements per Section 11.12
of the Carlsbad Municipal Code for additional information.
23 . Show existing lot line bearing and distance.
24 . Provide typical street cross sections for existing frontage streets and proposed streets. Provide
existing right-of-way width and existing improvements and proposed improvements and
dedications.
25 . Delineate and annotate proposed driveways and driveway width.
26 . Show truck turning radii. Plot turning radii per Caltrans figure 404.5B and/or 404.SF.
27. Provide 5-foot minimum back-up clearance at the last stall of the row of parking spaces.
28 . Show all existing utilities and callout size for: water, sewer, storm drain, underground dry utilities,
overhead lines, traffic signals, streetlights in Beech Avenue and laterals affecting the property.
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 9
29. All transformers and electrical facilities solely serving this project site shall be located on site and
outside of the public right-of-way
30. Obtain a letter from SDG&E confirming their approval of any proposed transformer location and
stating that no additional off-site facilities will be necessary for this project. Please also include
all existing and proposed dry utilities and the services that will supply power to the proposed
transformer.
31. A Sewer Study for new development based on City of Carlsbad Sewer Master Plan Update 2019,
Section 4.2 Design Criteria may be required, CMWD to make final determination.
32. A Water Study for the new development based on City of Carlsbad Potable Water Master Plan
2019, Section 4.2 Design Criteria may be required, CMWD to make final determination.
33. Public potable water and sewer mains along project frontages must meet minimum design
diameter and material as specified in City of Carlsbad Engineering Standards Vol. 2 Section 3.2.2
for water and Volume 1 Section 6.2 for sewer. Utility replacement and/or upsizing may be
required as a condition of development, CMWD to make final determination.
34. Locate fire service, backflows, potable and recycled water services, meters, landscape irrigation
services, and sewer laterals for the new development in compliance with City of Carlsbad
Engineering Standards requirements.
35 . Replace existing water service with a new PVC tee, meter and backflow per CMWD standard
drawing W-5.
36. • Ensure the trash enclosure design is consistent with the City of Carlsbad and Republic Services
standards.
37. Provide multiple cross-sections of the site to demonstrate differences in grade from adjacent
properties, existing _and proposed grades on-site, fences and location of structures on-site and on
adjacent properties.
38. Frontage improvements are required per CMC18.40 and/or CMC20.16. Public street frontage
improvements shall include curb and gutter, sidewalk, driveway, utility relocation, etc.
39. A 311 AC grind and overlay required for HALF STREET WIDTH OF Beech Ave._
40. Clarify if this will be rental apartments or for sale condominiums.
41. Show shoring walls along the property perimeter.
42. Meet with the Fire Department to identify the necessary fire protection measures required for
this project (access, fire hydrants, sprinkler system, on-site circulation, emergency access, etc.)
43. Plot stopping sight distance at all driveways.
44. This project may require off site grading improvements for the construction of shoring/retaining
walls along the property perimeter. Submit a copy of a recorded easement or an agreement for
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2024-0065 (DEV2024-0135)-MULTIFAMILY RESIDENTIAL DEVELOPMENT
January 22, 2025
Pa e 10
the offsite work from the owners of the affected properties with your application for a
discretionary or grading permit will be required.
45. Address the comments on the attached red lined plan.
46 . Please be advised that a more in-depth review of the proposed development will occur with the
discretionary permit application when a more complete design of the project is provided.
Public Works Utilities Design Department Comments (Markus Mohrle)
1. Submit a Water Study Analysis for the project that includes domestic meter and fire sizing criteria,
per the current Carlsbad Engineering Design Standards and applicable NFPA fire flow
requirements.
2. Submit a Sewer Study Analysis for existing and proposed demands for the public sewer main.
Note: Commercial and residential units shall require separate sewer laterals, and if there is
potential for a food service facility to occupy the commercial space compliance with FOG
requirements shall be required (CMC 13.06).
3. Project Plans shall be updated to identify all buried utilities in Beech Avenue right of way along
project frontage. Existing and proposed utility connections shall be properly located and sized for
proposed demands and shall be labeled with current standard detail references.
4. Proposed Ground floor layout shall preserve suitable locations and space for all required utility
connections, meters, and backflow devices in conformance with current Engineering Standards.
Identify locations and detail fire service, water, and sewer connections at property line for the
new development in compliance with current Carlsbad Engineering Design Standards.
5. Public potable water mains along project frontages must meet minimum design diameter and
material as specified in City of Carlsbad Engineering Standard Vol. 2 Section 3.2.2, and thus
upsizing shall be required as a condition of development along project frontage.
Building Division Comments:
Conceptual approval. Multiple submittal documents shall be required for Building Permit application
and plan review.
Carlsbad Fire Department Comments (Darcy Davidson, darcy.davidson@carlsbadca.gov ):
1. Show building height, and if applicable, location of Aerial Fire Apparatus Access road. Aerial
Fire Apparatus Access roads shall be provided when the distance from grade plane to highest
level of the roof exceeds 30 ft. The aerial access road must be a minimum of 15 feet and a
maximum of 30 feet from the building and shall be positioned parallel to one entire side of the
building. No overhead utility and power lines shall be located over the aerial fire apparatus
obstructions.
2. Provide documentation that hydrants are provided in the quantity and spacing described in
California Fire Code (CFC) Appendix and prove that they can deliver the amount of water
required by CFC Appendix B. Complete a P-99F form and submit to the fire permit technician.
The hydrant shall be located at least 40 feet from the building(s) it serves.
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600