Loading...
HomeMy WebLinkAbout2844 UNICORNIO ST; ; 86-100-A3; Permita: O I hereby attlrm that I am licensed under I[ provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is In lull force and effect. lie No Class 0 <->r I hereby affirm thal I am e)(empt lrom lhe Contrac-lor's l,oense Law 1or 1he lollowong reason (Sec 7031 5 Business and Protess,ons Code Any city or county which re- quires a perm11 to conslrucl alter. improve, dernohsl'I, or repair any structure, prior lo its issuance also requires !heap- phcant for such permit to Ille a st9ned statement thal he 1s licensed pursuanl to the pcovis10ns of lhe i;on1rac1or s License Law (Chapter 9 cDl'M'lenc1ng w11h Sec110n 7000 ot 0tv,s10n 3 ol the Bus,ness ~nd Professaons Code) or th.111s ex-empt lherelrom and lhe basis lor the allegeo exemphon Any v,o1a11on of Sect1011 7031 5 by an applcant for a perm11 sub-jecls lhe apphcant 10 a c,v,I penalty ol nol more lhan five hun· dre<I dollars ($500) a: I as owner m the property, or my employees with wages ... as their sole compensa110n. will do the work. and lhe siruc- 0 ture ,s not intended or olfer~ !or .saie (Sec 7044 Business .J and Professions COde. The ContractOf's license Law does 5 not apply 10 an owner of prope<ty who bu1Jds or improves I thefeon and who does such work himself or through his own employees. provided that such 1mpr011emenls are not 1nlend ... ed or olfered tor sate 11, however_ the tlmldmg or improve-z ment 1s sold w1ltl1n one year of complellOn. the owner•bu1kier ~ will have the burden of proving thal he did no1 build or 1m- 0 prove lor the purpose of sate} D I, as owner of lhe proper1y, am exclusrvety contractmg wnh lteensed contractors 10 conslruct the project (Sec 704-4, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or ,m- Cl) proves !hereon. anCl who contracls lor each protects with a contractor(s) hcense pursuant 10 the CoOlracto(s license z Law) 0 ;:: D As a homeowner I am improving my home. and the follow-C ing cond1t1ons ex,st a: 1 The work tS being per1orrned p<Klf 10 sale C 2 I have bved In my home tor twelve months .J <.> pr\Of to complehon 01 this work ... 3 I have not claimed this exemptton durmg lhe 0 last three years D I am exempt under Sec. for this reason , B&P C ---- D I hereby alf1rm that I have a cer11f1cate ol consent to self-insure. or a certificate of Workers Compensation In- rirance. or a certified oopy thereof (Sec. 3800. Labor Code) POLICY NO COMPANY ii :J Copy lS filed with !he city D Certified copy 1s hereby furnished ... a.. 2' 0 CERTIFICATE OF EXEMPTION FROM <.> WORKERS. COMPENSATION INSURANCE Cl) (This section need not be completed if lhe permit CZ: ... is for one hundred dolla,s tS 100) or less) " 0 I cer11ly lhat In the performance of the work for which a: 0 lh•s permit IS Issued. I shall not employ any person many :l manner so as 10 become subIect to the Workers Compen- sation Laws of Calilorma NOTICE TO APPLICANT. If. alter making this Cert1ficaIe ol Exemption. you should beeome subIect to the Workers· Compensat,on p,ovisions of u,e LabOr Gode. you must lorthwith comply with such provisions or this permit shall L be deemed revoked. l O I hereby affirm that there ls a construcOon lending ffi agency tor the performance of the work for which lh•s per- o mI1 ts issued (Sec. 3097. Civil COde) z ~ Lender's Name ______ ----~._ ~-I Lender s Address ___ _ __ I I I I U~t. D"Ll r"Ulftl rtrl VrlLT & r"fllt.~,) """u CARLSBAD BUILDING DEPARTMENT Carlsbad, California 92008-1989 (619) 438-5525 APPLICATION & PERMIT ll JOB ADDRESS AV. ST. RO, {J R4Ll DYl tcv r(fl \'O ,-s+ NEAREST CROSS ST. 1 0ATE OF APPLICATION! I~: 12.!l-. BLOCK OWNER'S NAME I SUB01 VISION ~_;!,, 1 Le. M..-0.. A'2-tP.tJ ~ '=t..~C OWNER'S MAILING ADDRESS AS~O\ ~C~N~(o(J -{sJ 4- 19 ~ ~w:2;;,~o;- CONTRACTOR lltJO'f OL~ CONTAACTOA"S ADDRESS DESIGNER v~a. 0 ~ hThvfc. <rAe.O '-"l T-( DESIGNER'S AODAESS L -------------------,-s,s.o., V2:.g..o~ Av~ ~fQ ~yf'fi!__ ~er~ 1-- CENSUS TAACl GP LANO USE PARK ING SPACE RES UNITS QTY. PLUMBING PERMIT -ISSUE rf,9 LLs:. EACH FIXTURE TRAP /I_ '7_.<;Q -z.-, 5-0 I EACH BUILDING SEWER -r;:.~ EACH WATER HEATER AND OR VENT ~--- //., .C"n I EACH GAS SYSTEM 1 TO 4 OUTLETS EACH GAS SYSTEM~ OR MORE i-(.SO F/P FLA ELEV. YO NO GRADING PERMIT ISSUED 1 REDEVELOPMENT AREA QTY. \ y O N 0 ,□ rvO MECHANICAL PERMIT -ISSUE INSTALL FURN DUCTS i.JP TD 100.000 BTU OVER 100,000 BTU BOILER/COMPRESSOR UP TO 3 HP BOILER/COMPRESSOR 3 15 HP MET AL FIREPLACE "'° STORIES TYPE CONST ~-- -z{. -- EACH INSTAl. ALTER, REPAIR WATER PIPE ·-+-- EACH VACUUM BREAKER 4-~-: VE NT FAN SINGLE DUCT (£.,.7{;_;-I J-1 -1.L' I -/l.(b MECH EXHAUST HOOD1DUCTS I WATER SOFTNER I j I RELOCATION OF EA FURNACE/HEATER I ----EACH ROOF DRAIN (INSIDE) ---~ /? k . .' TOTAL PLUMBING 1 ~Gf--to--:-:. QTY. ELECTRICAL PERMIT -ISSUE £...-QTY. J SOLAR -ISSUE NEW CONST EA AMP SWT BKR jQ'.) A. '1 <:: -COLLECTORS I PH 3 PH STORAGE TANKS EXIST BLDG EA AMP SWT BKR ROCK STORAGE 1 PH 3 PH PUMP REMODEL AL HR PER CIRCUIT PLAN CHECK FEE TEMP PO LE 200 AMPS OVER '200 AMPS TEMP OCCUPANCY 130 DAYSI lOTAL ELECTRICAL T I -;o ---~ I TOTAL SOLAR I BUSINESS LICENSE a VALUA'nbN \) PERMIT NUMBER 101-,1'50 CONTRACTORS PHONE • ZONE &fo-/l>(),~ LICENSE NO PLAN 1.0 . # BUILDING SO. FOOTAGE 1,41 DESIGNER'S PHONE <-1 t.i (..j --i et}S"'" LICENSE NO OCC GP EDU OCCLOAD I FIRESPR ~. 1:J lv, l R '&iD,,d Unlefs M~chine Cerril1ed !!/ I ?'B68939 aB67; ,, CJ.D----- SUMMARY,~S,~NT NUMBER BUILDING PERM1f ' .. (I c.iool:-sm-00-00-8220 4 ~'"S .-- SIGN PERMIT 00.~D PLAN CHFjq•v c1 CfAA-~ .:.Q;O.D·li.2~\I~ ~,4~ TOT1rf~~~ -~1 ?RSU:~jii:dil-s~2'2 Ei2 AL 001-810-00-00-8223 54"~- ~_Q.- 001-810-00-00-8224 tJ..f'J . - 001-810-00-00-8225 ~NG MOTION 880-519-92-33 -7.i:..5:_g_ FIRE SPRINKLERS 001-810-00-00·8227 U PUBLIC FACILITIES FEE 332-810-00-00-8930 -I--_ ------1 SCHOOL FEE • DISTRICT Carlsbad Enc,nr1as San o,e]l_uito San Marcos t~'T t, . LICENSE TAX oo 1-810-00-00-8162 I a..1 si;----MFF 880-519-92-57 CREDIT DEPOSIT .~o II TOTAL FEES PAYABLE ,-1 p, lb'?, 4'\ I HAVE CAREFULLY EXAMINED THE COMPLETED ·APPUCA110N AND PERMIT· AND DO HEREBY Exp,ratron Every perm11 issued by lheBu1ld1ng Ofhc1al underlheprov,s1onsoflh15 CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall exp,re by hmrtalion and become null and vo,d II lhe bu1ld,ng or wor• * IIIN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER S o·• DEEP AND DEMOLITION OR CONSTRUCTION Of STAUCT\JR!:S OVER 3 STORIES IN HEIGHT DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS aulhOnzed by such permit ,s nol commenced w1th•n 1B0 days from lhe daleul sucn ISSUED TO COMPLY WITH All CITY COUNlY AND STATE LAWS GOVERNING BUILDING CON perm,!, or ,f the bulld,n~ or work aulhorozed by such permil '5 suspended or STRUCTION WHETHER SPECIF I ED HERE IN OR NOT I ALSO AGREE TO SA VE INDEMNIFY AND '-:8::b::a::n"':do=-:-oed""'::"8::-1 ~•n..L.-"h"m:.::ec.c•=•:.:.•..;l:..:he::..:;wc::o::.rk::....::••:..c,::o:::m=m:.::e::.:n.::ced=.:.:10:::r..;a~=''7'o:::0"--"0::..1 ..:.1 BO=.,,d,,_a..,s,.._~:::-1'"~~~"""""""--------------------~ KEEP hARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND APPLICANT·S SIGNATURE lf-OWNE~ CONTAIIICTOA O APPROVED BY DATE EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ; .J_ _ ,11 /) _ f -/) '7 ¥~ GRANTING OF THIS PERMIT ~ ~, BY PHONE O I 0 ~ u: >-;;; 0 a. E <ll I- I 'O 0 (!) C "' -~ a. a. <( lgp ..>:: C a: 0 Cl) Cl) <ll Cl) Cl) <( I ::: 0 <ll >- Cl) Cl) <ll (.) 0 it "' «i 0 fl <ll (.) C "' C IL s C <ll ~ (!) 0 u <ll a. Cl) C <ll .c ~ TYPE ' l DATE INSPECTOR BUILDING I FOUNDATION ,, -REINFORCED STEEL /"J '"°' ~ns/:;1 er- M~SOr;IA'V S'/:V/r~ ;r' I • r GUNITE OR GROUT I SUB FRAME □ FLOOR □ CEIL;ING SHEATHING D ROOF □ SH'EAR -FRAME ,, ?//4/JL [7 EXTERIOR LATH 0.-, INSULATION I " ?//l'IJ'I rr ..... INTERIOR LATH & DRYWALL I " R/:i..1/rb rr r I I PLUMBING I □ SEWER AND BUCO □ Pl/CO /) UNDERGROUND D WASTE D ~ATER 5'~s-/.>t Ir- TOP OUT D WASTE D WATER 9/JJ/;~ IT TUB AND SHOWER PAN f I I _,... GAS TEST ' J//4/~~ / I D WATER HEATER D SOLAR WATER , I I ELECTRICAL I J D ELECTRIC UNDERGROUND D 1UFFER ROUGH ELECTRIC I P/14/r~ lr D ELECTRIC SERVICE D TEMPQRARY , ' t- D BONDING □ POOL I I MECHANICAL I .n D DUCT & PLEM., D REF. PIPING }'/'/,1/;J Ir" HEAT -AIR COND. SYSTEMS I ( I VENTILATING SYSTEMS I _l I CALL FOR FINAL INSPECT/ON WHEN ALL APPROPRIATE ___ IT_E_M_S_ABOVE HA l(E BEEN APPROVED FINAL PLUMBING ' ELECTRICAL ~ MECHANICAL GAS BUILDING SPECIAL CONDITIONS I I -· . ' I "I .""· " :" I I ' I '- ~ /) I _H~ ~ ,,. 11tl 1 I C /\ I FIELD INSPECTION RECORD REQUIRED SPECIAL INSPECTIONS INSPECTOR'S NOTES INSPECTION REO IF INSPECTOR S DATE CHECKED APPROVAL SOILS COMPLIANCE PRIOR TO . FOUNDATION INSP . STRUCTURAL CONCRETE OVER 2000 PSI ,. . PRESTRESSED CONCRETE POST TENSIONED CONCRETE FIELD WELDING HIGH STRENGTH SOL TS SPECIAL MASONRY , • ' " PILES CAISSOr-..S . . . • - ' ., :"'".I,;-·· .• -~_ -J . t . I ·-. City of Carlsbad 1200 ELM, CARLSBAD, CA 92008 • TEL. (61 9) 438-5525 r Job ~ Address r .. .., ; u... { .rl"'t-"T~• "'-~ 1,, / Y6 Owner KI 1\ i,A .l. ~ C.. Mailing J' ":> v-Address \, ~ -·~ ~,, I... City I Zip Tel. ~~tf .SIC .( J I{.. 01 Contractor f '---J... 1 Address J City I Zip Tel. State Uc. City S Classlf. .!:.!.£:. No. COMPLETE FOR P·:r:AN -K ON / LEGAL DESCRIPTION ~ --' t,e2 t t,\. 'I.,,,, I\. ~ I -~ ASSESSORS PARCEL NO ~, s-5 loo at a DESCRIPTION OF WORK 1PU-./'\ n ,':.:\ uA l..u. ~l toW1AU'~9- PLAN ID NO. ?6 /Od DESIGNER ADDRESS tf w I /lA..-<,1). .._ -{'"f • PHONE \ .;>t):J u J\ lJ' w'uv~ ",} 1 -, 0~ CONTACT PERSON -, .II . -, -' \ ~.., I ..,) I cl JJ•-<-' • ( I ,LJ. .A.11..Al_ '• I.... "'-1 ) CJ l' (.~ ( LI .l.AA.: ;1.;i Signature of Applicant Date \ \.. MISCELLANEOUS RECEIPT MISCELLANEOUS FEE RECEIPT □ • PLAN CHECK FEE 001-810-00-00-8806 □ VALUATION □ DEMOLITION □ HOUSE MOVING □ PARKS AND RECREATION FEE □ PUBLIC FACILITIES FEE □ SCHOOL FEE · DISTRICT ,□ Carlsbad □ Encinitas □ San Diego □ San Marcos □ CERTIFICATE OF OCCUPANCY n n n n n n □ □ □ □ □ TOTAL FEE • r q • &~~ $ •WARNING: PLAN CHECK FEES. WHERE NO ACTION IS TAKEN BY THE APPLICANT IN 180 DAYS AND NO BUILDING PERMIT IS ISSUED. ARE FORFEITED TO THE CITY. COMMENTS: White -Applicant Yellow -File Pink -(1) Finance (2) Data Process Gold -Assessor "" - . .J FINAL BUILDING INSPECTION PLAN CHECK NUMBER: DATE: PROJECT NAME: ---------------------------------- ADDRESS: PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: TYPE OF UNIT: _____________ NUMBER OF UNITS: INSPECTED I • / a BY: __ V\L___,__' --''-'-'-M_._..P_6'-=£'-=L'-=L INSPECTED BY: __________ _ INSPECTED BY: __________ _ DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: 3 -'3 -Y{ 7 APPROVED ~ DISAPPROVED __ APPROVED DISAPPROVED __ _ APPROVED DISAPPROVED , •• COMMENTS: ----------------------------------- Rev. 1186 WHITE: Suspense BLUE: Water Distrl ANARY: Utilities PINK: Planning GOLD: Fire I -FINAL BUILDING INSPECTION PLAN CHECK NUMBER: 86-100 A3 DATE: 3--I PROJECT NAME: ---------------------------------- PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: TYPE OF UNIT: -------=-=-".:..;rl:..:..._ ____ .....--__ NUMBER OF UN ITS: l CONTACTPERSON:. ___ ---=-=.c.:.:.ch-'--'--'-'~1..:....:..c.t ~------------------------- INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: ----------------------------------- Rev. 1/86 WHITE: Suspe e BLUE: Water District G EN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire FINAL BUILDING INSPECTION I PLAN CHECK NUMBER: 06-100-AJ DATE: 3--87 PROJECT NAME: I ADDRESS: 2844 UnicOrnio St PROJECT NO.: UNIT NUMBER: PHASE NO.: TYPE OF UNIT: fd NUMBER OF UNITS: 1 CONTACT PERSON: !'; chn1it.v CONTACT TELEPHONE: 944-2885 t INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: ---------------------------------- .STS Sw Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Eng neerl PINK: Planning GOLD: Fire FINAL BUILDING INSPECTION PLAN CHECK NUMBER: DATE: PROJECT NAME: ---------------------------------- ADDRESS: PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: TYPE OF UNIT: _____________ NUMBER OF UNITS: I&~ , INSPECTED DATE !!.j' ' 1 -13 "J BY: INSPECTED: APPROVED DISAPPROVED I INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: ----------------------------------- ,, Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utllltl ESGIL CORPORATION 9320 CHESAPE.\KE DH.. Sl:ITE ::?08 SAN DIEGO. CA 921::?3 (61 9) 560· 1468 DATE: IHtlRCU 2.t,, , I 'f q 5 cR~CANT JSDICTiolD JURISDICTION: (KLj BIUJ 0 PLAN CHECKER 0 FILE COPY OUPS PLAN CHECK NO: D DESIGNER PROJECT ADDRESS: PROJECT NAME: D D ■ □ II 0 □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _______________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone I REMARKS: --------------------------- BY, d ;il/4,_., il-J2f- ESGIL CORPORATION 3/zo ENCL: -------- .. .. ESGIL CORPORATION 9320 CHESAP£AKE DR .. Sl.'ITE :?08 SAN DIEGO, CA 9:? 123 (6W) 560· 1468 DATE: ,,.,fJ(2{J.i 5 . , <f¾ □APPLICANT &JURISDICTION QPLAN CHECKER 0 FILE COPY QUPS JURISDICTION: CITY OF CARLSBAD PLAN CHECK NO: ;t,... qq . ~ c-:.,.,-,,..,I 0 DESIGNER PROJECT ADDRESS: 'OJS 517. S°''n : r ,..-; . 1J,,Jl{:)('rl1t) PROJECT NAME: T'Cc pl , J! 7 , e / , F ::;.. D D □ ffl □ □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _______________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant 's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgi l staff did advise applicant t hat the plan check has been completed. Person contacted: Date contacted: Telephone# REMARKS: Cf:iHf/11.e::a 1-~r:,10 vP1.:11,~-. c .. ' Pee AYt,.k lcA P ,:-T\ t>· -nu: . .:..r 0-Vl\1:T: P,[( (ltA:::1/lf PLAII ama II). % _qq I Sra -/A;) .S1o -ID I JURISDlc:rION: CJ.'IY OF CARLSBAD DLXPHIIX ll>. ---'7'--{._.o"------a. .... ~_-t_.z. ____ _ l!llCLOSORJ!S: -------------- PliDJICr ADDRJ!SS: PI.All CORREC:rION S8EKr SDG:.X FAMILY AllD OOPLEX DWELLIHGS Date plans received by jurisdiction: Date plans received by Esgil Corporation: Date initial plan check completed: Applicant contact person: ____ ~ ... ;Ji .... ~,_ ... tt ... P ____ Telephone: 74 q -: JI Z.. POREWORD: PLEASE RKAD Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1982 UBC (eff.7/1/85) 1982 UPC (eff. 10/1/85) 1984 NEC (eff. 10/1/85) 1982 UMC (eff. 3/1/85) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1982 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad List 10, Single Family Dwelling and Duplex With All Supplements 1 2/13/86 ..____:. /. Please make all corrections on the original /tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Suite ( 619) Corporati on, 9320 Chesapeake Drive, #208, San Diego, california 92123, 560-1468. ~ Please make all corrections on the original Yacings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. /· Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302 (a) 7 . / Plans, specifications and calculations shall be signed by a california state licensed engineer or architect. (california Business and Professions Code}. ,J, Specify on the Title Sheet of the plans the /gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302 (c). ~ Provide a statement on the Title Sheet of Ve plans that this project shall comply with Title 24 and 1982 UBC, UMC, and UPC and 1984 NEC. j. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes and approximate finish floor elevations for all structures and show elevations at all lot corners. Section 302 (c ). 2 2/13/86 / Indicate distance from center line o; alley to property line and distance property lines to proposed building. Section 302 (c). B. P'IRI PROIECIIOII of street from /· Walls closer than 3 feet to property lines shall be one-hour rated construction, have no openings, and shall have 30 inch parapets when the building floor area exceeds 1,000 square feet on any floor. (Table 5. A. Section 1709 (a)). "#>-Projections, including eaves, may not 'extend 1110re than 12 inches into the 3 foot setback from the property line. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 1710 and Section 504 (a) and (b}. µ. Plastic skylights shall not be installed within 8' of an exterior wall located where openings in such exterior wall are prohibited or required to be protected. Section 5207 (a) 7. 11.. Projections, including eaves, shall be one-hour.fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1710. ~ Show location of permanently wired smoke ~ector, centrally located in corridor leading ~-~~~~ping _rooms .a; above stair if sleeping rooms are on upper level. Section 1210. um;-.E, --sH:Ji,J Ji.. S-rA-1~ f,;!(, f<':=:..DCA,~ r1<~m J!1i"C.HEAJ A c.Le.~"!':-T6 t b6J ~ -S:::.t=: "Sf,,1£!::.1 0 -B A smoke detector shall be installed in the ement of dwelling uni ts having a stairway which opens from the basement into the dwelling. Such detector shall be connected to a sounding device or other detector to provide an alarm which will be audible in the sleeping area. Section 1210. C. 1101»1 SIZES, UGHI, VDI'IL\l'IOII AND GLAZI1IG I 15. Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. Section 1207 (b). '(6. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a). Appears to be deficient in /1. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laW1dry rooms and similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. (Section 1205 (a)).· I 1,8· At least 1/2 of the coDJDOn wall must be open and have an opening not less than 25 sq. ft. if light and ventilation is being supplied from an adjacent room. Section 1205 (a). l~. Required windows shall not open into a ;oofed porch Wlless the ceiling is at least 7 feet and the longer side is at least 65% open. Section 1205 (a). J. Provide mechanical ventilation capable of ~roviding five air changes per hour in bathrooms, water closet compartments, laWldry rooms and similar rooms if required openable windows are not provided. Section 1205 (a). ti. No habitable room, other than a kitchen, shall be less than 71011 in any dimension. Section 1207 (c). ¥,. Show that ceiling height for habitable rooms is a minimum of 7'6". Section 1207 (a). 'U3. Show ceiling height for laW1dry rooms, ~llways, corridors, and bathrooms is a minimum of 7'0". Section 1207 (a). 3 2/13/86 'f · Dimension on the plans, the 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 511 (a). ~-Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Section 5406. 2~. Glazing, in the same wall plane as a door, aiust be safety glazing if within 12" of the door and less than 6011 above the walking surface, Wlless the glazing is leaded on faceted glass. ·section 5406 (d) 7. 27. Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic (including windows within 5 feet of tub or shower floor). Section 5406 (d) 5. 1/'· Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5. 7 square feet with the minimum openable width 20" and the minimum openable height 24". Section 1204. f· A mezzanine is an intermediate floor and may not have a floor area exceeding 33 1/3 percent of the total floor area in the room below. The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height. Section 1716. 3~. The loft you show does not comply as a ~zzanine floor and is, by Uniform Building Code definition, a story. Section 1716. D. l!Xl'IS, S?AIJIWAYS, A!ID RATT.TJCS fl. Floors above the second story shall have not less than 2 exits. Section 3303 (a). 3f. Required exit door.rays shall be not less ~ 36" in width and not less than 6' 811 in height, and shall be capable of opening at least 90 degrees. Section 3304 (e). Q Provide 36" high protective railing for ¥rches, balconies, and open sides of stai;t.. landings. Openings between railings s~lL.!2~ less than 611·:· Section 1711. Q Show how guardrail coMection details are 'i?equate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. 'SEE 4'--"';:!, ~ Provide stair.ray and landing details. Vction 3306 (b) & (c). 0 Maximum rise 8" and minimum run is 9". ~-Minimum headroom is 616". f . Minimum width is 30". Q All handrails per Section 3306 (j), shall ~isfy the following: Provide handrail for stair.rays with 4 or more risers. Handrail shall be 3011 to 3411 above the nosing of treads. The handgrip portion of handrail shall be not less than 1 1/4" nor more than 2" in cross-sectional dimension. (See attached). 4 2/13/86 h7J Every stair.ray landing shall have a ~nsion, measured in the direction of travel, at least equal to the stair.ray wi<!th. Section 3306 (g). Ullrr 3 Ii!-uPP!::K Lf\Jl:L oz.es uo-r MP t:A'e. -ro t..:) m p L 'f '.}8, A door may open over a stair.ray landing provided the door, in any position, does not reduce the clear area of the landing in the direction of stair.ray travel, to less than one-half the required width of the stair.ray. Section 3306 (g). '!fl· A door may open inward at the top step of a stairlolay provided the top step is not more than 7 1/2" lower than the floor level. Section 3304 (h). 4p. Provide details of winding stair.ray complying with Section 3306 (d): a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. b. Maximum rise is 8 inches. c. Minimum width is 30 inches. iJ.. Provide spiral stair.ray details, per Section 3306 (f): a. b. c. Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9 1/2 inches. Minimum headroom is 6 feet 6 inches. 4/ Spiral stair.rays may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). 4/,. Spiral stairways must have a clear walking I space of 26 inches between the column and handrail, show dimension. Section 3306 (f). 1,/,+. Provide I.C.B.O. Research Report and Number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication shall be done under special inspection per the approved fabrication plans. Section 306 (a) 4B and Section 306 (f). 'f'• In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stairway. An exit balcony with 2 separated stairways is exempt. Section 3306 (1). J6. Exterior stairways shall not project into /the 3 foot setback from the property lines. Section 3306 (n). ~ The walls and soffits of the enclosed Vable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). E. ROOFDC 4$. Specify roof slope. I 4/J. Roof slope is not adequate for roof type ~pecified. Table 32-B; Section 3203 (h). 56. Specify roof material and application. Chapter 32. :Ji. Specify I.C.B.O. or U.L. approval number !or roof materials not covered in U.B.C., e.g ., title, etc., Section 107. 5 2/13/86 5J. :be maximum slope for a fire retardant built-up roof, with rock or gravel surfacing, is 3 inches in 12 inches, Section 3203 (e) 2. ':/3. The minimum slope for a fire retardant built-up roof, with cap sheet surfacing, is 1/2 inch in 12 inches. Section 3203 (e) 3. 'f· Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a), Section 2305 (f) and Section 2511 (d) 6. f5. Show roof drains and overflows. Section 3207. r,. Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.O. approval number. /1. Plastic skylight must be separated from each other by at least 4 feet. Section 5207 (a) 6. Q Show attic ventilation, Minimum vent area Yl/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). F. MASONRY :/9. Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Oiapter 37. f:/J. Show veneer support and coMections in ieismic Zones 3 and 4, comply with Section 3002, 4, 5, 6, and Section 2515 (a) regarding ties and #9 wire in horizontal joints or show construction to be per attached sheets 30-1 or 30-2. 6i. Show height and construction details of all I masonry walls. Chapter 24. 6/. Note that cleanout openings shall be provided at the bottom of all cells to be grout filled over 41 in a single pour. Cleanout shall be sealed before grouting, after inspection. Section 2414 (a) 8. 63. Show floor and roof connections to masonry walls. Connection shall resist 200 powids per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers·is not permitted. Section 2312 (j) 3. A. (I+. Provide details for damp proofing the fowidation walls, below finish grade, where useable space exists on the interior side of the walls. Section 1707 (d). ff'• Show a minimum 2" air space and flashing between planter and building walls. Section 2516 (c) 7. G. GARA.GE ARD CARPORTS &t,. Garage requires one-hour fire protection on ,the garage side of walls and ceiling co111110n to the dwelling. Table 5. B. Section 503 (d). 6J. All elements supporting floor above garage, including walls supporting floor joists, to have one-hour fire-resistive protection on the garage side. Section 503 (a). o/3· Show 1 3/811 solid core self-closing door for openings between garage and dwelling. Section 503 (d). 6_~. Garages are not permitted to open into a room used for sleeping purposes. Section 1104. 6 2/13/86 "'fJ· Openings between carport and residence require self-closing doors and stationary windows . Section 1214. Q Show garage framing section, size of header Yer garage opening, lateral cross bracing at plate line, method of bracing garage front, and holddowns if required. Chapter 23. NOTE: Maximum plywood diaphragm ratio of height to width is 3 1/2 to 1. Table 25-I. 1).. Doors may open into the garage only if the floor or landing in the garage is not more than 1/2" lower than the door threshold. Section 3304 (h). 1/. Provide an 18" raised platform for any FAU, water heater, or other device in the garage, which may generate a flame or spark, UMC Section 508, UPC Section 1310 (a). B. FOOHDATIOII R.£001..kmKN'.rS 1i. Per soils report, note on the plan the soils classification, whether or not the soil is expansive, and note the allowable bearing value. Section 2905 (c). J/:,. The fowidation plan does not comply with hie soil report recommendation for this project. Please review the report and modify design, notes and details as required to show compliance. ~6. Provide notes on the fowidation plan listing the soils report recomnendations for fowidations, slab and building pad preparation. I j-,. DI& soils report recoanends excavations be reviewed by soils engineer. Note on the foW\dation plan that "Prior to the Contractor requesting a Building Department Foundation Inspection, the soils engineer shall advise the building official in writing that: 1. the building pad was prepared in accordance with the soils report; 2. the utility trenches have been properly backfilled and compacted, and; 3. the foundation excavations, formings and reinforcements comply with the soils report and approved plan". 1). Show height of all foundation walls. Chapter 23. 114. Show height of retained earth on all foundation walls-. Chapter 23. o/J..• If cut or fill slopes exist, show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. 8l. Note on plans that wood o/inimum above finish grade. Section 2516 (c) 7. shall be 611 r/2. Note on plans that surface water will drain ,way from building and show drainage pattern and key elevations. Section 2905 (f). A.,.-LE:1¥..-f IA., (cl .s·-1.,:,• ~ So1L~ r· Dimension foundation per U.B.C. !able 29A: Floors Susmorted* 1 2 3 Stemwall 6" 8" 10" Width 12" 1511 18" Depth 1211 18" 2411 *Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. r/,.. Show foundation sills to be pressure freated, or equal. Section 2516 (c) 3. 85. Show foundation bolt size and spacing. Section 2907 (e). ~ Specify size, I.C.B.0. number and ~ufacturer of power driven pins. Show edge and end distance and spacing. Section 306 (f). Q If required by structural calculations, Vow size, imbedment and location of hold down anchors on foundation plan. Section 2312 (f). ~J. If hold downs are required by calculations, note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 2. Jg. Show adequate footings under all bearing lalls and shear walls. Section 2907 (b). 10. Show on the elevations, stepped footings for slopes steeper than 1:10. Section 2907 (c). 91. Show minimum 1811 clearance from grad& to bottom of floor joists and minimum 12" clearance to bottom of girders. Section 2516 (c). @ Show pier size, spacing and depth into undisturbed soil. Table 29-A. ~3. Show minimum underfloor access of 18" x 24". Section 2516 ( c). 9).. Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c). 0,;iffilr.f )$ -.::) c,!h',l ci::i-e:-1".lO lHJ(;'T"rl ,,,..,:; l'1; 8M £;,i:::E;: ~ )t's;l;T ' -8 7 2/ 13/86 ~-Specify that posts embedded in concrete shall be pressure treated per UBC Std. No. 25- 12. Section 2516 (c). I. PIIAKIJIG ~ Show wall bracing. Every exterior wood ~ wall and main cross partition shall be braced at each end at least every 25 feet of length with 1 x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3. ":>\UU ~,J l:.Lf:.VA-f1D,J.!S rf Q)~_l, t-lOi" f<H ·•-.t1~ 1"fi-l'li ~ll I Li/llJl, VJ_ILL CCm f1.;1 oh t.,.11,11 .c:r::n, ,,J -z.-s 11 c.~1 RJe. ~ef•l.1 i,1C. • i' . Note cross oridging or bloclu.ng. Floor joists and rafters 12" or more in depth shall be supported laterally by bridging at inter.vals not exceeding 8 feet, unless both edges are held in line. Sec. 2506 (g). r· Show blocking at ends and at supports of floor joists, and for rafters at exterior walls. Section 2517 (d) 3. t9. Show solid blocking at ridge line and at exterior walls on trussed roofs. Section 2506 (g), Section 2517 (h). 190. Show double joists. Floor joists shall be doubled under bearing partitions running parallel with the joists. Section 2517 (d) 5. l9'i. Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist. Section 2517 (d) 5. 1~2. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h) 4. f03. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 5. 8 2/13/86 11,4. Show 1/211 minimum clearance between top J1ate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). ifs. Show double top plate with mini.mum 48" lap splice. Section 2517 (g) 2. 1~6. Show nailing will be in compliance with iable 25-Q. 1d1. Show or note fire stops at the following Jications per Section 2516 (f): a. in concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals along the length of the wall. b. at all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; c. in concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are wlfinished; and d. in openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. 1QA. Show stud size and spaci ng. Maximum allowable stud heights; Bearing wall: 2 x 4 and 2 x 6 max. 101 ; Non-bearing: 2 x 4 max. 14', 2 x 6 max. 20'. Table 25-R-3. 1r_. Studs supporting two floors, a roof and ceiling must be 3 x 4 or 2 x 6 at 16" o.c. Table 25-R-3. .. 1io. Note an A.I.'I.C. Certificate of Compliance tor glued laminated wood members shall be given to the building inspector prior to erection. Section 306 (f). 1/1. Detail all post to beam and post to footing connections and reference the detail to the plan. Section 2516 (m). Q Detail shear transfer connections, ~uding roof and floor diaphragms, to shear walls. Section 2513. Q Specify nail size and spacing for all ~~ walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. (Tables 25 I, J, K) and Section 4713 ( d). <7t.J>rJ/j 1rll.L:Jef: ':.d-H,lCuL~ Ql.l"f Loc.A'noil": ~£Tr ~~;,j d ON l't..Ar l!) -'5E.l:.. #JU> 1'l14. Show 311 x 411 or 2" x 6" studs in first story of three story building. Table 25-R-3. 1~. Provide truss details and truss calculations for this project. 1/6. Provide roof framing plan and floor framing plan. Section 302 (a) 7. 1b. Provide framing sections through I Section 320 (a) 7. Q Specify all header sizes for opening over ~ide. Section 2517 (g) 5. Q Provide calculations for main vertical and ~zontal framing members and post footings. Section 302 (a) 7. Q Provide calculations for lateral loads, ~ panels, shear transfer and related. Section 302 (9) 7. v>sr t\ \'.lt\l'lj 9 2/13/86 (i;:;:) Show on the plans all structural ~irements developed in the structural calculations. 11ft . Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. 11/3. Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. 1/4. Show location of attic access with minimum size 22" x 30". Section 3205. 1i5. Show draft separation for attic areas between units in a duplex. Section 2516 (f). l'd6. Wood stud bearing walls, with studs at 2411 d.c., require 3 ea. 2 x 4 or 2 ea. 2 x 6 or 2 ea. 3 x 4 top plates if supporting either floor members or roof trusses that are spaced more than 1611 o.c. and do not bear within 511 of the supporting stud. Section 2517 (g) 2. Q Specify plywood grade and panel ~tific.ation index. Table 25-N. f<Lef • C.DX: h.occ. , -~ 1/s. When roof pitch is less than 3:12, design ridge as a beam. Section 2517 (h). li9. If foundation cripple wall studs are less than 14" framing shall be solid blocking. Section 2517 (g) 4. / I I 1i. Cripple wall studs exceeding 4 feet in ~~gnt shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. Q Show plywood sheathing ove: expose~ eaves, Vother weather exposed areas, 1s exter1or grade. Section 2516 (g) 3. C...OJ( I~ ~L~ t:;'(ff.'felcie .. [.,,1bWE' -u<:.e CLx w 111d 1/2. Show a weep screed at the foundation plate line on all exterior and stud walls to be stuccoed. Section 4706 (e). 1/3. Show corridor width to be minimum 36". Section 3305 (b). 13J. Specify truss layout for 30" x 30" attic adcess. Q Ridges, hips, and valleys shall be at ~tone size larger than supported rafters. Section 2517 (h) 3. 'S~~J ~lr.E. 1/6. In open beam construction, provide strap ties across the beams at the ridge support. Section 2501 (b). .J. MiCIAJIICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 1/1. Show the size, location and type of all heating and cooling appliances or systems. 1~. Show source of combustion air to furnace, per Chapter 6, UMC. ~9. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC Sec. 1211. 10 2/13/86 ltO. Show minimum 3011 deep unobstructed working s ace in front of furnace. Section SOS, UMC. lfl. Note on plans, clearances to be per manufacturer's listing. Section 504, UMC. 1f 2. Furnace shall not be installed under any stairway. Section 704 UMC. lib. Furnace shall not be installed in any ~droom, bathroom or in a closet or confined space with access only througn such room, unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. 1'4. Show I.C.B.O. approval number for prefab fireplace. ifs. Show access to the attic or underfloor furnace to be minimum 30 inches by 30 inches. Section 708 & 709 UMC. ~6. Note that passageway to the attic furnace shall~ unobstructed and have continuous solid flooring not less than 24 inches wide. Section 708 UMC . 147 . Show permanent electrical outlet and lignting fixture controlled by a switch for the attic furnace. Section 708 UMC. 1~. Show details to comply £/or furnace under the floor, roof or outside furnace. with Section 709 or Section 710 for 9 Note on plan: Gas vents and noncombustible piping passing througn three floors or less shall be effectively draft stopped at each floor or ceiling. UBC Section 1706 (a) 6. K. ILl!CIRICAL {IIATIONAL KLECI]UCAL COOK) All wiring shall comply with the National Electrical Code. 1fo. Show on the plan the ~erage of the . electrical service, the location of the service panel and the location of any sub-panels. 1/1. Show location of all electrical receptacles. Q Electrical recepta~le locat~ns and/or " ¥cing is not adequate in 6rf t1 C,, -C ;/c, .J 1 { 'rlCl.l ;?orJ-r H L ~Ef'.7 ft'ft 1-h\ CrJ ~EH\J t!: 1\l OlJT U:, 6 1':<' ,:Qrl't'( n\ ',<I ~ '· L L G:w. A-IA -°'-~~-.., 12·,'I ,-Al 1J3, Show at least one convenience outlet other than outlets for laundry, etc., outdoors, in garages and basements. Nee. Art. 210-52. Q Note convenience outlets in bathrooms, ~oors, and in garages and basements (other than for laundry and similar equipment) shall be GFI protected, NEC Art. 210-8. ALL !lt..r.'U,"75 1/s. Note electrical system ground to be provided per NEC, Art. 250-81. L. PLlltBIK; {UHD'ORH PL1J4BIK; CX>DK) 1J6. Show water heater size, type and location on plans. UPC, Section 1310. 157. Show source for providing combustion air ' to fuel burning water heater. If wall opening in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one-half within the lower twelve inches. UPC, Section 1307. 11 2/13/86 1¥3, Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom. UPC Section 1309. 1~. Provide adequate barrier to protect water heater from vehicle damage. UPC Section 1310. Q Show T and P Valve on water heater and ~ route of discharge line to exterior. UPC, Section 1007 (e). Ci'J Provide dryer vent to outside. ~~· Section 1903. Q Note on the plan that hose bibbs and lawn ¥:i.nkler systems shall have approved backflow prevention devices. UPC, Section 1003. 113. Shower stall shall acco111DOdate a 3011 circle and have a minimum floor area of 1,024 sq. in. UPC 909 (d). N. ll>ISK IllSULA:rION {DUPLKXES) lf4, Show details of duplex co111non (party) walls and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of SO decibles and on Impact Insulation Class (IIC) rating on floor/ceiling of SO decibles. Title 25. 1Js. Show how penetrations of assemblies for r{iping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 25. 1(.6. Provide insulation in walls and ceiling to achieve STC of 50 between garage and living area if garage use is not controlled by resident. Title 25. . ' JI. IIIIRGY CONSDVATIOII: PLKASlt READ State regulations (California Admin. Code) require that the design satisy one of the attached alternative energy packages or submit calculations. The law also requires that many mandatory conservation items be satisfied. 1/1. Show on the Title Sheet of the plans, the required elements of the alternative energy package that was selected, and next to each element show how you are complying with each element. If calculations were used, provide similar data on the plans. Q "Die plan sheet showing the required ~~ts of the selected energy package, and listing the design elements showing compliance with that selected package, must be signed by either the owner or a licensed professional i.e., architect, engineer or contractor. A design professional must note his/her state license number . Section 1403 of Title 20. e Show on the plans the "R" value for the w~ls, floors, ceiling and related areas. 'l'ACUP~ 1 ;('erl'lvltc.!'~ e-~o c..E1ul'-)6 -fL.k~ -s ;..\0w e.-A Q Show double glazing as per Energy Design, ~lazing Schedule. r'~avcl~ DoDe.5 17~. Show on the plan how shadi ng requirements are satisfied. up. "Die plans are not in compliance with the energy conservation compliance package selected or design calculations provided. Show on plans conformance as follows: 12 2/13/86 1/3. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, ''Mandatory Energy Conservation Requirements". G'J Show the size, type, make, model and ~tion of the space heating (or cooling) system and provide energy calculations if the output BTU/Hr. exceeds 45,000. 0. ~ S.F .D. & OOPLKX stJPPL»mff 1/s. Energy conservation design should be for Zone 7 See attached energy packages. 176. Floor drains must have auto-prime (city policy). Q Note exhaust fans cannot be ductl ess type ¥Y policy). 17b. New residential units must be pre-plumbed fdr future solar water heating. Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). 119. Note "two 3/4" copper pipes must be i/istalled to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No . 8093). lPf· All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy). 1ryi. Incorporate the waterproofing details, on the attached Policy 80-8, where interior living space occurs below grade at the masonry wall(s). j ~ Show on the Iitle Sheet on the plans, the ~rmation required by the attached Developmental Services Sheet 102683. 1rp. All new residential buildings, including additions, require a soils report. Please submit two copies. lff · Heavy timber framing, minimum 6" x 10" beams and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). ¥35. Please see additional corrections, or remarks, on the following page. The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, california 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact K°A''i'_ l/ ~:(/ C:,P ___ at Esgil Corporati on. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 1200 Elm Avenue, telephone 619/438-5525. Thank you. Enclosures: 1. 2. 3. 13 2/13/86 •• CITY OF CARLSBAD Date, ':S·S:·Sfr Prepared by, C;A r,' 'f NJ l ,EL VALUATION AND PLAN CHECK ~EE o Bldg, Dept, □ Esgil PLAN CHECK NO, 9G. -"l4 ' ¾ -1~ . e0 -1-:, I BUILDING ADDRESS --'~'-c'~'-C-C.t~·o~i~,,~J ________________ _ APPLICANT/CONTACT --fc11:: 6-PP Pt::' l['-1 PHONE NO. 74q -~ 3 1-z.._ BUILDING OCCUPANCY R-=, J 01-I DESIGNER PHONE ------TYPE OF CONSTRUCTION v' -") CONTRACTOR PHONE ----- BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER 1/.,a, utl-nMJ awe,. ff:;,Pn,,1' PC, r!:IE Al11l!'i1,J t, -r4 f t:-A L,v 1rJ1, .Pfif A 1,41 m • 5,:;;, -IDl'J°l7~ 1-,~J? f.l-/,,.~_ 44oJb x J.LJ -/,,/ f,,,r) DIEL.KS :--8 t-lr f '7 -1,,,,7 ---m--r t:1L I n7 7,,,,-cJ 453,otJ zq4,4< ' I B w:...o,,,Jr,.,. -r'lf'E!" 8 I . Liv,rJe, tk~1.-1 .'8,:)g ;jJ "y ~~-I /r0C?✓,,d,. : f-• A/? {f(rP ..J.ao .,':1 '< I 4 -l,,,1 lot:, I --rv-rfr' J II N?.4-4L?, ,/)/) I ~ q<; I I Air Conditionin~ Commercial @ I I Residential (cl I Res. or Comm . Fire Surinklers @ Total Value fee Adjusted To Reflect 0 Energy Regulations (fee x 1.1) 0 Handicapped Regulations (Fee x 1.065) • Building Perm it Fee $ _____________________ _.._ ______ _ Plan Check F ee_S~ __________________ _....;S'--------- CO 11 11 EN TS,_:----------------------------- 0/4/82 \ . PLAN CHECK NUMBERl-_6--/()I) ADDREESS .J,/Y'( Yf.~ f Jf s-O ~~/0:E ,,2.-v6 -M PLANNING '-( ,11,d//. ~~--<~ o , w 0::: :::) 0 w c::-+-- V) z-.- 0 1-~:ll....-u 4,1 UJ 3: Ck'. 4,1 ~-> ~ C, Q.I Ill ~J CX: C 1-u 4,1 w 3: ex: 4,1 ex: ·-QI 0 > ... 4,1 "' u 0::: Q SCHOOL FEES: SAN DIEGUITO CARLSBAD SETBACKS: FRONT REDEVELOPMENT PERMIT REQUIRED: SIDE ENCINITAS SAN MARCOS REAR -----------+--------- ADDITIONAL COMMENTS: \ ENGINEERING LEGAL DESCRIPTION VERIFIED?~--APN CHECKED?~------- P.F.F.: N/~ PARK-IN-LIEU QUADRANT: N/8 , FEE PER UNIT: r I -llfl ---- RIGHT -OF~WAY: -.0~ TRAFFIC IMPACT FEE PER UNIT:_L~.,_p,._.'{J.__ __ _ EASEMENTS: M ~ -0 I( DRIVEWAY~ ~ ~ ' uqg ~ IMPROVEMENTS: f✓ ~ ~:)~wxO ~A , FIELD CHEC~~TE: 3/rt/9ro INIT~~ -E.-D.-u.-:: ___ l-=_c-w_-...;_o-=_-=_-=_-=_-=_-=_-=_-=_-=-__ tJffE~,~~ f:,-.'%(.;o )...(.WO INDUSTRIAL WASTE PERMIT: N/F;;., __ ...,,~------LATERAL: GRAD ING PERMIT: f✓ ~p ~ ~""-OK _;5{{_ GRADING COMPLETION CERTIFI ED: ----------·--------- DRAINAGE: Wo::~ OV\. ~' ADDITIONAL COMMENTS: ------------------------ OK TO ISSUE&-'~---'0--"';;a...~.oe~=::::---~C. ____ DATE:_..0..,..,~-'/-~ __ /?_~------- DPD2:DPD6:01 /86 SAN MARCm UNI FIED SOIOOL DIS'IRI CT PROJEa' SERVICE AVAII.ABILI'IY IEITER (Applicant il in -print legib y LCXi. 00. _________ _ APPLICANI':_--=-A.:.:..r...:.i ..:::a..;..:n..::.a_-G..::.a;:c..r'-d'-'a'-l_i_t..,._y-',_I _n_c ___ ~-------~ Ph9~e .tb. Address: 13008 Vista Vi ew Dr Poway, CA 92064 --------- 0.YNER: ___ ...::,;:uuc.__ __________________ _ Phone .tb. __________ _ Address: _______________________________________ _ PROJECT DESCRIPI'ION l>roject located on Assessor's Parcel No.(s): ( Attach legal description if necessary) F-=-==-=~= ( check one or rrore) 0 Minor Subdivision (TPM) D tfajor Subdivision (TI.I) Project Address/Location Lots fiUi, 516, 517 La Costa Meadows No . 3 (Un1cornio) -'}-n--pli-, ~ ~ess--,:::-' s Par. eel Ntmbers 1. I~ L:::.r:.D ~ as· [TI] [II] OJ 2.1 I , 1CIIJCD 4. ITIJCIIJCD Housing Type No. of D.U. 's Single Family ~lultiple Family l~ 8 Mobi lehane Units No. of Bed.rocns 1. ().mer/applicant agrees to reconfirm this pro,iect with the issuing school district every 6 rronths unless such action is not required by the district. District Phone____,;6::.:l:.:~:......:..7.=.44=--.:4:..:7...:.7.=.6 _____ _ 2. ().mer/applicant understand that the certification for school service contained in this Project Service Availability Letter is no l onger effective if the pro,iect is disapproved or if the con- ditional project approval (subdivision, permit, or other conditional use processes) expires. 3. The infonnation I have prov· Date~7,_--""{p__,-'5""'--"'-6"---- S ICT CERTIFICATION ~ . L A ~-AVAII.ABILI'IY Date: IO [[C] DAY c::Q:m YR ~ 'TO : :rna.1: City of Carlsbad School District San Marcos Unified K-12 Grades Served: _____________ _ l. D School services and facilities are ccmnitted for this nroject. SPrvices will be available concurrent with project need based on a s~ured agreenent with the developer which has adeouate financing and clear intent. 'Recertification of servke availability is required prior to issuance of building permits. 2. []IX)the undersigned school district hereby certifies that i t will be able to provide adequate school services and facilities to the above described pro.iect concurrently with the need of such project. ().mer/applicant has p:1id the required deve loper's fee. 3. □ The undersigned school district hereby certifies that it wil l not be able to provide adequate school services and facilities to the above described project concurrently with the need of such project because ______________________________ _ _ } ~/A_ May 13 DISTRICT REPRESENI'ATIVE' S SIGNATURE ---~'-'--"=c......,q..----""-~__._.c.i...,c_._..__ Date. __ M_~_i(~_t-:_~_,_l_9_8_6 ___ _ TITI.,E ___,F_,a"-'c'--'i'-'1__,_i-=t'--'-i -"-e-"-s_T-'-e.;c...c_h ___ Phone_7_4_4_-_4_7_7_6 ______ _ 1 n'T'lc _rnnr l<'TITT'T'T'V VVT J OW-nTSTRTCT PTNK-OWNER/APPLICANr RECEIPT ate M 13 19 BC, 0702 Received From __ _,__.L..L.~.a....:::::...='-----=::L..L='--------------1 Address. ____ ....::;.c:..>.£..J..L-~.L...,,:::z_=-.--.L...J.--""'-=-=--------~ 1--------....._.,.._,._"""""'.c;_-""""--r-__.,_..-a,...,:__-----1c.=...--Dolla AMT. PAID CHECK BALANCE MONEY DUE ORDER 8K808 ~(i) , _,/-80-/0D r~/. ;£_ . . ~ &:~---.rr-1 -~4- s~. s-.z. .. ~ /Ge p~ #/&3-$ A~~~~ -~~ • ~✓-o,,e:~~ ~ • . 20-saM ~z¼ ~$, • ~~~1