Loading...
HomeMy WebLinkAbout2836 UNICORNIO ST; ; 86-101-A2; PermitC O I hereby affirm that I am licensed under I[ provlalona of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profeaalons Code, and my license is In full force and effect. Loe No Cl•ss 0 u r I hereby attum that I iffl exempt from lhe Contrac ID< s Locense t.,,. !or the toOowmg r .. son (Sec 7031 S Business ~ Pr01essions Code Any city 01 county which re quires a pemut 10 cons1ruc1, alter improve demohsh or repa,r any struclure, pr.or to I1s issuance also requires !heap-p1teant tor such Ptftnll to t11e a StQned statement that he 1s licensed pursuant 10 lhe prov1s10ns ol lhe eonuac101 s License Law (Chapler 9 commencing with Section 7000 of OMs,on J of the Business and Profess,ons Codt; or that ,sex empt 11\efelrom and the bis•s tOf the auegecs exemptiOC\ Any voOlaloon of SecloOn 7031.S by an appI,can1 l0< a pe,m,1 sub )eels lhe apphcant to a cIvII penally of not more than frve hun died dollars (SSOO) a:: I. as owner of Ure property. or my empioy .. s w,1h wages "' as the,r sole compensation, will do 1ne work, and lhe struc- 0 lure ts not intended or oflerec, fOJ sale (Sec 70A• Business ~ and Protess,ons Code Thi Conlractor·s license Law dots 3 not apply to an owner or ptoperty wno bu,lds or improves ! thereon and who does such work himself or through his own employees. provKled that such improvements are not mtend· "' ed or offered '°' gle It howe'ier, the bu1k11ng Of improve· z ment ,s sold w1th1n ooe year of complehon. the owner•bu11def ~ will have the burden ol provmg that he did not buIk1 or 1m• 0 prove IOI' the purpose of sale) 1. as owner ol lhe property, am excluSNely contracting with llcensed conuactors lo construe! the proteet (Sec 7044 Business and Profess,ons Code The Contractor's L,cense Law does not •wly 10 an owoer ot property who t,u,lds"' ,m-.,, p,oves tnereon, and who coolracts fOf each prOJtcls wtlh a contraclOf{S) license pursuanl to !he ContractOf·s ueense z Law) 0 .= t~ As a """'-ner I am ,mprrMng my home ilOd !he tallow C ,ng cond1hons exIs1 a:: t The work Is being per1ormed prt0r 10 sale C ~ 2 I have ~ved m my home lor lwelvt mon1hs 0 r:: :"~~::: l~~:-=~hoo during lhe "' 3 C last three years C' I am exempl unde< Sec tof this ruson B&PC D I hereby attirm that I have a cer11hcate of consent lo sell-insure. or a cert1hcate ot Wooters Compensalton In• surance. or a cert1hed copy thereof (5ec. 3800. Lal>Of COde) POLICY NO z 0 COMPANY .= ~ C L.J Copy IS filed Wtlh the city .,, D Certihed copy 1s hereby furnished z "' ... :IE 0 CERTIFICATE OF EXEMPTION FROM 0 WORKERS COMPENSATION INSURANCE .,, (This section need not be completed if the permit a: "' is tor one hundred dollars {$1()0) or less) "' C I cerhty that in the performance of the work fOf which a:: 0 this perrmt Is issued. I shall not employ any person in t1ny 3 manner so as to become subject to lhe Workers· Compen- sallon Laws of California. NOTICE TO APPLICANT· If, after making this Cert1f1cate ol Exemption. you should become sub1ec1 to the Workers COmPensation pro-visions of the Labor Code. you rnust for1hwith comply with such provisions or this permit shall L be deemed revoked . [ 0 I h.ereby aftum that !here Is a construction lending ffi agency IOf the performance of lhe wol1t fo, wh,ch this per o mIt ls ,ssuect (Sec 3097, C1V1I Code) z MJ Lender s Name ~ I Lenders Address __ -· I I I ....... ~ -.-..... • """•', L-n vnLt a ,.,.It~~ """U '" APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. CARLSBAD BUILDING DEPARTMENT Carlsbad, California 92008-1989 (619) 438-5525 ) APPLICATION & PERMIT ~ JOB ADDRESS ::;;_ 8 .a <.o AV~-ST.RO. ~T-CROSSST. IOATEOFAPPL ICATION BUSINESS LICENSE # VALUATION LOT BLOCK SUBOIVISOON O CONTRACTOR S-15 -o OWNEffS NAME 1 o,. 15FJ CONTRACTORS PHONE • ZONE '? LICENSE NO. PLAN 1.0. # PERMIT NUMBER I~ >- 8(c-\o\- I .i A.;i. BUILDING SQ. FOOTAGE V\ ESS .,___,,""'-............... '-"-....... ""'-..:Crc.....::._C'-'4-_._....:....-4--____________________ __.~~-~------, I -, '-+\ 1~ 3 \ 3 DESIGNER OESJ'!;.R'S PHONE DESCRIPTION OF WORK ..3 l3~/Jt'7rc-l~ Av tf 29&~ DESIGNER'S ADO-RESS LICENSE NO I NO I CCC GP (!) -{ij .S? a. a. I d--,. ~-~ -~--~-...,.....,-~-U-1..-u-l ~-~-CLc-~-------F,P FLA ELEV """~5) ..,,-\ '°~ ~ I ST~ES ~ ,--C::,,-. vO NO ---2B67~4p ~ BP NT TYPE OCC LOAD YO ,-o( I CONST:-) CENSUS TRACT GPLANOUSE PARKINGSPACE RESUNITS GRAOINGPERMITISSUEO =~~;VELOPME •• ,..,.. •--......... •'"''' _.:.. 1..\-40 \ YO Na( YO"~ I I \/-1\. l I I v□ Nn I •'NotValidU~hif11,£eitifiM YD NIX I V-1\. QTY. PLUMBING PERMIT· ISSUE EACH FIXTURE TRA .s-o 7 fl,. I ~TY-l MECHANICAL PERMIT. 1ssuE I c:5 _ I suMMARY/Acc~~t::f$s~~ -;:,,,-, .i;-d \ J INSTALLFURN OUCTSUPT0100,0008TU I ll -I BUILDINGPERMIT 001-810-00-00-8220 I -4SS - EACH BUllOING SEWER OVER 100.000 BTU SIGN PERMIT 001-810-00·00·8221 EACH WATER HEATER ANO OR VENl 801 ITTICOMPRESSO R UP TO 3 HP PLAN CHECK 001-810·00-00-8806 . ct~ EACH GAS SYSTEM I TO 4 OUlLElS l EACH GAS SYSTEMS OR MORE -~-~ BOILER/COMPRESSOR315HP TOTALPLUMBING 001~·00·00-8222 , ___ 59._ -- METAL FIREPLACE -ELECTRICAL 001·810·00-00-8223 :::.t.n _.. EACH INSTA~ ALTER, REPAIR WATER PIPE L+ -~ I EACH VACUUM BREAKER WATER SOFTNtR :J .st) VENT FAN SINGLE oucr::::2, ;:;i..;-I e . -I MECHANICAL 001·810-00-00-8224 I c;X O -I MECH EXHAUST HOOO DUCTS I ft MOBILEHOME RELOCATION OF EA FURNACE/HEATER I U MOBILEHOME PARK INSP 001 ·810·00·00-8225 EACH ROOF DRAIN (INSIDE) 101 AL PLUMBING HAIN (IN:>IUt) ~ -SOLAR __ 0_01·810-00-00-8226 I l STRONG MOTION 880-519-9_?·33 '7d_f .:i.o. -5q - QTY. FIRE SPRINKLERS 001-810-00·00·8227 ELECTRICAL PERMIT -ISSUE -,..!>-QTY. I SOLAR -ISSUE PUBLIC EAC'h'TIES FE_E 332-810·00·00-8930 NEW CONST EA AMP SWT BKR \ o-o-A d5=_~ COLLECTORS SCHOOL FEE -OISTRICT I PH 3 PH STORAGE TANKS Carlsbad EXIST BLOG EA AMP'SWT BKR ROCK STORAGE Enc1011as 1 PH 3 PH PUMP San D1eguIto REMODEL AL HR PER CIRCUIT PLA'J CHECK FEE San Marcos J.:T~ TEMP POLE 10D AMPS OVER 100 AMPS -LICENSE TAX 001-810-00-00-8162 fEMP OCCUPANCY (30 DAYSI MFF S ta U'.)""'t:) 880-519-92·57 CREDIT DEPOSIT lOTAL ELEURICAL T 30.-TOTAL SOLAR TOTAL FEES PAYABLE -r .!J, \ ss:- /ts{.~Q~ --aE:, _tc,J. 4-'\ I HAVE CAREFUI.J.-Y E!l,AMINED THE COMPLETED APPLICATION AND PERMIT" AND DO HEREBY CERT;FY UNDER PHiAL"TY OF PERJURY THAT ALL INFOR'-IATION HEREON (NCUJDING THE DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CEFTIFY AND AGREE IF A PERMIT IS ISSUED TO COMPLY WITH ALL CITY COUN1Y AND STATE LAWS GOVERNING BUILDING CON S•RUCTION WHEH<ER SPECIFIED HERE.IN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABIUTIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WA'Y ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT Expiration Every permit issued by the Bu1td1ng Offtc1al under 1he provIsIons of th,s Code shall ex.pire by lim,tat,on and become null and 'f"0•d If th~ bu1ld1ng or worll authorized Dy such perm rt is nol commenced w,1n,n 190 days from the date of si..c"'i perm,t. or 1f the building or ¥r0rk autnonzed by such permit 1s suspenoed abandoned at any t,me after the work ,s commenced tor a period or 180 days * AN OSHA PEllMIT IS REQUIRED FOR EXCAVATIONS OYER 5 0 DEEP AND DEMOl.lTION OR CONSTRUCTION OF STRUCT\IRES OYER 3 STORIES IN HEIGHT ;;;;;_~OWN,;,: CONTRACT 1 '1',,JK....J'-"_,...._.._~ -~--a-~ DATE -I ti f (e,"-2 -" C: 0:: 0 1/) 1/) ~ 1/) 1/) <( I ~ 2 ~ >- 1/) 1/) ~ u 0 a: <O '° 0 fi w u C: <O C: u: C: ~ ~ (!) 0 0 ~ a. 1/) C: ID .c ~ TYPE I DATE INSPECTOR I BUILDING I FOUNDATION "-t. REINFORCED STEEL ,.., :" ~h~J,, ~ 4-MAS0t~R¥-5t.Ad ~/nr I . . , GUNITE OR GROUT I SUB FRAME O FLOOR □ CEl t.;ING /) SHEATHING 0 ROOF □ SHEAR 7//~l ~r ~ FRAME I 7//-,./,r IT"" EXTERIOR LA TH I , , I • ,.., INSULATION :'--.. 7//5/rt ,~ INTERIOR LATH & DRYWALL I 'r/u11'J r I -I PLUMBING I □ SEWER AND BUCO D Pl/CO /) UNDERGROUND D WASTE D WATER ~/lo Jr, T,,, TOP OUT D WASTE D WATER 74.P/~, 17'-" TUB AND SHOWER PAN , , I .,, GAS TEST I 7//#',, IY I D WATER HEATER D SOLAR WATER , , I ELECTRICAL I D ELECTRIC UNDERGROUND 0 1UFFER .... ROUGH ELECTRIC I 7//4/ I'' 17"' D ELECTRIC SERVICE D TEMPORARY D BONDING D POOL I l I MECHANICAL I l .,. D DUCT & PLEM., D REF. PIPING 7//4/)1. IT HEAT -AIR COND. SYSTEMS , , --. I VENTILATING SYSTEMS I . I CALL FOR FINAL /NSPECrnON WHEN ALL APPROPRIATE ITEMS ABOVE HA E BEEN APPROVED. FINAL PLUMBING ELECTRICAL MECHANICAL GAS BUILDING SPECIAL CONDITIONS I I "' : ~ I '\. I I I I ' I 17 • 1-r . k l r 1 I '\. I1 r I '- ' < ---~~---- ~(o--10 I FIELD INSPECTION RECORD REQUIRED SPECIAL INSPECTIONS INSPECTOR'S NOTES REO IF INSPECTORS ~ INSPECTION. DATE I CHECKED APPROVAL . . SOILS COMPLIANCE , PR•OR TO , FOUNOA TION INSP -· i . - S TRUCT dRAL CONCRETE ,)VER 2()1>0 PSI .. PRESTRESSEO CONCRETE POST TENSIONED CONCRETE FIELD WELDING --HIGH STRcNGTH BOLTS ~ SPECIAL MASONRY • ~ -I ' ..... ' ·- PILES CAISSOII.~ ... ., ,..:, . . . . . . . ' - . . A I • ~ f /.I . ," .... ' r.' I';' _A . . ----. . ,, I . .. .. . -. - PLAN CHECK NUMBER: PROJECT N TYPE OF UNIT: FINAL BUILDING INSPECTION _______ PHASE NO · CONTACT PERSON: ______________________________ _ . CONTACT TELEPHONE: _____________________________ _ ~y~PECTED~ INSPECTED BY: _________ _ INSPECTED BY: _________ _ COMMENTS: y o-r DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: SE€ /$€C..t>C</ APPROVED L DISAPPROVED --- APPROVED DISAPPROVED __ _ APPROVED DISAPPROVED __ _ FINAL BUILDING INSPECTION PLAN CHECK NUMBER: PROJECT NO.: TYPE OF UNIT: __ __.:_:,:....:..:.. _________ NUMBER OF UNITS: CONTACT PERSON:. _______________________________ _ CONTACT TELEPHONE:. ______________________________ _ ,,, ~y~PECTED A~~ INSPECTED BY: _________ _ INSPECTED BY: _________ _ DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: .I r < ,, ' ~~( ' r c½' I :, l ~ L j L ' APPROVED APPROVED APPROVED __ _ / ' .rro<-~ v# -Z.P<;PZ ,//zr-5 rJ/~b DISAPPROVED __ _ DISAPPROVED __ _ DISAPPROVED __ _ Rev. 1186 EN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire FINAL BUILDING INSPECTION PLAN CHECK NUMBER: DATE: PROJECT NAME:---------------------------------- ADDRESS: PROJECT NO.: ________ UNIT NUMBER: ________ PHASE NO.: TYPE OF UNIT: __ ___:_.:.=....:..: _________ NUMBER OF UNITS: CONTACT PERSON: ________________________________ _ CONTACT TELEPHONE: _______________________________ _ ... 1 _ ... INSPECTED BY: __________ _ INSPECTED BY: __________ _ INSPECTED BY: __________ _ DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED DISAPPROVED __ _ DISAPPROVED __ _ COMMENTS: ----------------------------------- Rev. 1186 WHITE: Suspense BLUE: Water District GREEN: Engineeri g CANARY: Utilities PINK: Planning GOLD: Fire l f FINAL BUILDING INSPECTION PLAN CHECK NUMBER: DATE: 3 PROJECT NAME:----------------------------- PROJECT NO.: _______ UNIT NUMBER: _______ PHASE NO.: ______ _ TYPE OF UNIT: ____________ NUMBER OF UNITS: CONTACT PERSON: ___ .5=""")+-'-e.....,_,.i/'-'e'..,_<""----------------------- CONTACT TELEPHONE: __ _,q'-4_.__4.,__-_,c___,e,__._.,p,'--"-~....::::-,.___ ______________ _ ~Nv~PECTED f?m d ~Ny~PECTED I{ Pl(J6 DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: ~-S ~lo,JB) 12-~ 842. APPROVED ./ DISAPPROVED ~ /-/'1~7 APPROVED V DISAPPROVED __ APPROVED / DISAPPROVED __ co~~~~½ <2 lo n.1 &m el e .ie, 1:tw: l r. \ O"'ij > ) A .,,.-ti I O Ji;; '""' Crn.i.. l l ? G-,4-~t 1e:t~' ;;;:;~:$;0 ~ec Eil.e ~k1J~fe Dlc.n:5 on± re#v,~ed: ot) 1>/c,n f>c Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utlllti ESGIL CORPORATION 9320 CIIESAPE.\KE DR .. Sl'ITE 208 SAN DIEGO, C.\ 92123 (6 J 9) 5()()-J .... (,8 DATE: IHtU'cll: 2/, , I 9 86 ~CANT JSDICTigj::> JURISDICTION: D PLAN CHECKER D FILE COPY QUPS PLAN CHECK NO: D DESIGNER PROJECT ADDRESS: Lll'11c DI(' tJ1Q PROJECT NAME: D D • □ 0 D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _______________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to r eturn to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: _______ Telephone j REMARKS: __________________________ _ . I I l t i ESGIL CORPORATION 9320 CHESAPE.-\KE DR .. SL'ITE 208 SAN DIEGO. C.-\ 92123 (619) 560-I ~68 DATE : ,nPf2. ct-I 5 , , 'fE.t:.,, APPLICANT URISDICTION LAN CHECKER 0 FILE COPY OUPS JURISDICTION: CITY OF CARLSBAD PLAN CHECK NO: B~· q q, $0,· IM •8 0 DESIGNER PROJECT ADDRESS: 101s 511, s11q r;,5 -l!ftl!{Okclu) PROJECT NAME: □ D f1A □ fZl □ □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _______________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at Esgil Corp. until corrected plans ar~ submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed . Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone# REMARKS : cf:l€ck'ti.c,:r .1:1No v p L,u~-, n/ Ar?€ 1WVk lc AP-1t T.\ t: .. --nn: . .::.r EtI<z)l:f: AC ( UC C;:i 1(1(' '1, JUIUSDicr:ION: CITY OF CARLSBAD 1'0: 41EJ/£ 6GR OJI! I (I l54Q$ Vl"'.1,4 V/E;W ERtir:' l'.ELXl'B)l(E NO. ___ 7..._.-(.,.B ___ -_C: ... -... ,; __ 1,..z,...._ ____ _ El!ICLOSORKS: --------------- PROJl!CI ADDRESS: PLAMOORRECT'IONSIIKKr SDG.E FAKILY AMO OOPLEX DWKLLIHGS Date plans received by jurisdiction: Date plans received by Esgil Corporation: Date initial plan check completed: 3 · 5 -f:k By: C..Aer./ .,tJrJk E L Applicant contact person: __ __. ... X[i .... ~_1_1r:f._.., ___ Telephone: 74q -! 51 2- F<>REl«>RD: PI.KASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. Toe plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1982 UBC (eff.7/1/85) 1982 UPC (eff. 10/1/85) 1984 NEC (eff. 10/1/85) 1982 UMC (eff. 3/1/85) Toe above regulations apply to residential construction, regardless of the code editions adopted by ordinance. Toe items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cit ed codes and regulations. Per Sec. 303 (c), 1982 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city l aw. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad List 10, Single Family Dwelling and Duplex With All Suppl ements 1 2/13/86 { Please make all corrections on the original /tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. ~ Please make all corrections on the original Vacings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. /· Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302 (a) 7. / Plans, specifications and calculations shall be signed by a California state licensed engineer or architect. (California Business and Professions Code). ,J. Specify on the Title Sheet of the plans the /gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302 (c). ~ Provide a statement on the Title Sheet of Ve plans that this project shall comply with Title 24 and 1982 UBC, UMC, and UPC and 1984 NEC. /· Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes and approximate finish floor elevations for all structures and show elevations at all lot corners. Section 302 (c). 2 2/13/86 l or Indicate distance from center line of street alley to property line and distance from property lines to Section 302 (c). proposed building. B. FID PROIECI'IOH /· Walls closer than 3 feet to property lines shall be one-hour rated construction, have no openings, and shall have 30 inch parapets when the building floor area exceeds 1,000 square feet on any floor. (Table 5. A. Section 1709 (a)). f · Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 1710 and Section 504 (a) and (b). ),.1.. Plastic skylights shall not be installed ~ithin B' of an exterior wall located where openings in such exterior wall are prohibited or required to be protected. Section 5207 (a) 7. 0.. Projections, including eaves, shall be one-hour.fire-resistive construction, heavy timber or of noncombustible material if they project into the 31 setback area from the property line. Section 1710. ~ Show location of permanently wired smoke ~ector, centrally located in corridor leading __!2..-~~~ping room~_o~ above stair if sleeping rooms are on upper level. Section 1210. LJfl)rr' .E3 -'S,-bt,J ,IL Si/f/R Ar IO F<!!LDLA,'E r12Dm J!,-rc.H EtJ Ac.L E::BS T-1 t: b6.J --Se.IE .t:::,H££=:t h -8 4. A smoke detector shall be installed in the asement of dwelling units having a stairway which opens from the basement into the dwelling. Such detector shall be connected to a sounding device or other detector to provide an alarm which will be audible in the sleeping area. Section 1210. I I I . , " c. RO(Jt SIZES I LIGKt I VElffILIJ.IOI( AMI> GLAZiltG I 1,5. Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. Section 1207 {b). "i6. Window area must be at least 1/10 of the i1oor area and a minimum of 10 square feet per Section 1205 (a). Appears to be deficient in /1. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. {Section 1205 (a)).· I }8· At least 1/2 of the co111DOn wall must be open and have an opening not less than 25 sq. ft. if light and ventilation is being supplied from an adjacent room. Section 1205 (a). 1~. Required windows shall not open into a roofed porch unless the ceiling is at least 7 feet and the longer side is at least 65% open. Section 1205 (a). -i/J. Provide mechanical ventilation ~apable of ~roviding five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1205 (a). n. No habitable room, other than a kitchen, ~hall be less than 7'0" in any dimension . Section 1207 (c). 1f-Show that ceiling height for habitable ro~ms is a minimum of 7 '6". Section 1207 (a). W,. Show ceiling height for laundry rooms, ik11ways, corridors, and bathrooms is a minimum of 7'0". Section 1207 (a). 3 2/ 13/86 r· Dimension on the plans, the 3011 clear width for water closet compartments and 24" clearance in front of water closet. Section 511 (a). U,. Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Section 5406. if. Glazing, in the same wall plane as a door, must be safety glazing if within 12" of the door and less than 60" above the walking surface, unless the glazing is leaded on faceted glass. Section 5406 (d) 7. 27. Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic (including windows within 5 feet of tub or shower floor). Section 5406 (d) 5. 1/"· Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5. 7 square feet with the minimum openable width 20" and the minimum openable height 24". Section 1204. i/J. A mezzanine is an intermediate floor and /nay not have a floor area exceeding 33 1/3 percent of the total floor area in the room below. The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height. Section 1716. 36. The loft you show does not comply as a oiezzanine floor and is, by Uniform Building Code definition, a story. Section 1716. D. EXrrS. STAIRWAIS. AND MPJllGS /1. Floors above the second story shall have not less than 2 exits. Section 3303 (a). 3i. Required exit doorways shall be not less ~ 36" in width and not less than 6'8" in height, and shall be capable of opening at least 90 degrees. Section 3304 (e). Q Provide 36" high protective railing for ¥rches, balconies, and open sides of staiI:... landings. Openings between railings shall be less than 6';-. Section 1711. Q Show how guardrail connection details are 'i:?equate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. 'SEE ..t" "'.J3 ~ Provide stairway and landing details. Vction 3306 (b) & (c). 0 Maximum rise 8" and minimum run is 9". Minimum headroom is 6'6". Minimum width is 30". Q All handrails per Section 3306 (j) , shall \disfy the following: G Provide handrail for stairways with 4 or more risers. Handrail shall be 30" to 34" above the nosing of treads. The handgrip portion of handrail shall be not less than 1 1/4" nor more than 2" in cr oss-sectional dimension. (See attached). 4 2/13/86 Q Every stairway landing shall have a ~ension, measured in the direction of travel, at least equal to the stairway wicth. Section 3306 (g). Uu rr f3 ft. u PP~rl LEVkL ozes \Jar MP ~Ale.. --ro [1) m p L 'f '.}8-A door may open over a stairway landing provided the door, in any position, does not reduce the clear area of the landing in the direction of stairway travel, to less than one-half the required width of the stairway. Section 3306 (g). 'f· A door may open inward at the top step of a stairway provided the top step is not more than 7 1/2" lower than the floor level. Section 3304 (h). 4f-Provide details of winding stairway complying with Section 3306 {d): a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. b. Maximum rise is 8 inches. c. Minimum width is 30 inches. iJ.. Provide spiral stairway details, per Section 3306 {f): a. b. c . Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9 1/2 inches. Minimum headroom is 6 feet 6 inches. 4/. Spiral stairways may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). 41. I Spiral stairways must have a clear walking space of 26 inches between the colUJID'l and Section 3306 (f). handrail, show dimension. i,J... Provide I.C.B.O. Research Report and Number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication shall be done under special inspection per the approved fabrication plans. Section 306 (a) 4B and Section 306 (f). J.,. In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stairway. An exit balcony with 2 separated stairways is exempt. Section 3306 (1). J6. Exterior stairways /uie 3 foot setback from Section 3306 (n). shall not project into the property lines. M The walls and soffits of the enclosed \?able space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). E. ROOFIMi 4p. Specify roof slope. ~-Roof slope is not adequate for roof type lpecified. Table 32-B; Section 3203 (h). 5b. Specify roof material and application. I Chapter 32. :/2.. Specify I.C.B.O. or U.L. approval number tor roof materials not covered in U.B.C., e .g., title, etc., Section 107. 5 2/13/86 5/. :he maximum slope for a fire retardant built-up roof, with rock or gravel surfacing, is 3 inches in 12 inches, Section 3203 (e) 2. :/3. The minimum slope for a fire retardant built-up roof, with cap sheet surfacing, is 1/2 inch in 12 inches. Section 3203 (e) 3. r4· Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a), Section 2305 (f) and Section 2511 (d) 6. f5 . Show roof drains and overflows. Section 3207. ¥>· Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.O. approval number. /1. Plastic skylight must be separated from each other by at least 4 feet. Section 5207 (a) 6. Q Show attic ventilation. Minimum vent area Vi/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). F. MASONRY f9 . Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. fl). Show veneer support and connections in ieismic Zones 3 and 4, comply with Section 3002, 4, 5, 6, and Section 2515 (a) regarding ties and #9 wire in horizontal joints or show construction to be per attached sheets 30-1 or 30-2. 6i. Show height and construction details of all I masonry walls. Chapter 24. 6/-• Note that cleanout openings shall be provided at the bottom of all cells to be grout filled over 4' in a single pour. Cleanout shall be sealed before grouting, after inspection. Section 2414 (a) 8. 63. Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension wood ledgers is not permitted. Section 2312 (j) 3. A. or bending in (I.. Provide details for damp proofing the foundation walls, below finish grade, where useable space exists on the interior side of walls. Section 1707 (d). 6f,. Show a minimum 2" air space and ietween planter and building walls. Section 2516 (c) 7. G. GARAGE AND CARPORIS flashing the the Garage requires one-hour fire protection on garage side of walls and ceiling co11111on to dwelling. Table 5. B. Section 503 (d). 6J. All elements supporting floor above garage, including walls supporting floor joists, to have one-hour fire-resistive protection on the garage side. Section 503 (a). o/3· Show 1 3/8" solid core self-closing door for openings between garage and dwelling. Section 503 (d). 6J-Garages are not permitted to open into a room used for sleeping purposes. Section 1104. 6 2/13/86 "f· Openings between carport and residence require self-closing doors and stationary windows. Section 1214. Q Show garage framing section, size of header Ver garage opening, lateral cross bracing at plate line, method of bracing garage front, and holddowns if required. Chapter 23. NOTE: Maximum plywood diaphragm ratio of height to width is 3 1/2 to 1. Table 25-I. 71. Doors may open floor or landing in 1/211 lower than the Section 3304 (h). into the garage only if the the garage is not more than door threshold. 1/. Provide an 18" raised platform for any FAU, water heater, or other device in the garage, which may generate a flame or spark, UMC Section 508, UPC Section 1310 (a). B. FOU11DAl'IOII REQ911(ffl£NIS 11. Per soils report, note on the plan the soils classification, whether or not the soil is expansive, and note the allowable bearing value. Section 2905 (c). 1f.,. The foundation plan does not comply with the soil report reco11111endation for this project. Please review the report and modify design, notes and details as required to show compliance. 7J. Provide notes on the foundation plan listing the soils report recolll!lendations for foundations, slab and building pad preparation. j-,. The soils report recommends excavations be reviewed by soils engineer. Note on the foundation plan that "Prior to the Contractor requesting a Building Department Foundation Inspection, the soils engineer shall advise the building official in writing that: 1. the building pad was prepared in accordance with the soils report; 2. the utility trenches have been properly backfilled and compacted, and; 3. the foundation excavations, farmings and reinforcements comply with the soils report and approved plan". 1). Show height of all foundation walls. Chapter 23. 7~. Show height of retained earth on all foundation walls. Chapter 23. Pf_· If cut or fill slopes exist, show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. sf. Note on plans that wood u/iniIIrum above finish grade. Section 2516 (c) 7. shall be 611 ft}.. Note on plans that surface water will drain 'way from building and show drainage pattern and key elevations. Section 2905 (f). A-( U:AS"'f lo" (o( S ·_lo' ~ So1L~ r· Dimension foundation per U.B.C. Table 29A: Floors Su1111orted* Stemwall Width Depth 1 6" 1211 12" 2 8" 15" 18" 3 10" 18" 24" f<Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. 7 2/13/86 r4. Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. as. Show foundation bolt size and spacing. Section 2907 (e). ~ Specify size, I.C.B.O. number and ~ufacturer of power driven pins. Show edge and end distance and spacing. Section 306 (f). Q If required by structural calculations, Vow size, imbedment and location of hold down anchors on foundation plan. Section 2312 (f). st. If hold downs are required by calculations, I note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 2. g9_ Show adequate footings under all bearing lalls and shear walls. Section 2907 (b). ~O. Show on the elevations, stepped footings for slopes steeper than 1:10. Section 2907 (c). '11. Show miniIIrum 18" clearance from grade to lottom of floor joists and miniIIrum 12" clearance to bottom of girders. Section 2516 (c). @ Show pier size, spacing and depth into undisturbed soil. Table 29-A. ?3· Show miniIIrum underfloor access of 1811 x 2411 • Section 2516 (c). 9)... Show miniIIrum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to comers as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c). l..Y',1 LI W/lrt.L ~-Specify that posts embedded in concrete shall be pressure treated per UBC Std. No. 25- 12. Section 2516 (c). I. P1WIIllG ~ Show wall bracing. Every exterior wood ~ wall and main cross partition shall be braced at each end at least every 25 feet of length with 1 x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3. -:,lll)U) o,J l:,1.f:.\JAft0~J.s rf Q)~ MOT'" ~~f';.A~ "Tfl·AT /1UILVIUl, WIU. lOrllf'i.:( oh l 1'lill "'.rU11 'tJ 1.."51 7 (.~") ~,e. '6€fll.lNG· i '" Note crossoridging or blocking. Floor joists and rafters 12" or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held in line. Sec. 2506 (g). f· Show blocking at ends and at supports of floor joists, and for rafters at exterior walls. Section 2517 (d) 3. 99. Show solid blocking at ridge line and at /exterior walls on trussed roofs. Section 2506 (g), Section 2517 (h). l?O-Show double joists. Floor joists shall be doubled under bearing partitions running parallel with the joists. Section 2517 (d) 5. 1¥.. Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist. Section 2517 (d) 5. 1,2. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h) 4. f03. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 5. 8 2/13/86 164. Show 1/2" minimum clearance between top J1ate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). 1p5. Show double top plate with minimum 48" lap splice. Section 2517 (g) 2. 1~6. Show nailing will be in compliance with table 25-Q. 1d1. Show or note fire stops at the following lk>cations per Section 2516 (f): a. in concealed spaces of stud walls and partitions, including furred spaces, b. c. d. at the ceiling and floor levels and at 10 foot intervals along the length of the wall. at all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; in concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are wuinished; and in openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. lo,8. Show stud size and spacing. Maximum ailowable stud heights; Bearing wall: 2 x 4 and 2 x 6 max. 10'; Non-bearing: 2 x 4 max. 14', 2 x 6 max. 20'. Table 25-R-3. lc}g, Studs supporting two floors, a roof and c'iling must be 3 x 4 or 2 x 6 at 16" o.c. Table 25-R-3. 1io. Note an A.I.I.C. Certificate of Compliance lor glued laminated wood members shall be given to the building inspector prior to erection. Section 306 (f). 1(1. Detail all post to beam and post to footing connections and reference the detail to the plan. Section 2516 (m). Q Detail shear transfer connections, ~uding roof and floor diaphragms, to shear walls. Section 2513. Q Specify nail size and spacing for all ~~ walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. (Iables 25 I, J, K) and Section 4713 ( d). <7LMJ~ 1rl LLI.Jaf: ":c:H1:::.uuL~ ~Uf LOC.A'flol'I~ ~DT ~~"'J r-1 ON 9U1rl~ -'SE:.e-~I u:> 1J/4. Show 311 x 411 or 2" x 611 studs in first story of three story building. Iable 25-R-3. l~. Provide truss details and truss calculations for this project. li6. Provide roof framing plan and floor f~aming plan. Section 302 (a) 7. 1J7. Provide framing sections through Section 320 (a) 7. Q Specify all header sizes for opening over ~ide. Section 2517 (g) 5. Q Provide calculations for main vertical and ~zontal framing members and post footings. Section 302 (a) 7. Q Provide calculations for lateral loads, ~ panels, shear transfer and related. Section 302 (9) 7. 0 i), ~ fl.t\fl j 9 2/13/86 ~ Show on the plans all structural 'te/uirements developed in the structural calculations. 17ft. Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. 13/3-Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. 1✓4. Show location of attic access with minimum s(ze 22" x 30". Section 3205. 1i5. Show draft separation for attic areas between units in a duplex. Section 2516 (f). 11/6. Wood stud bearing walls, with studs at 24" d.c., require 3 ea. 2 x 4 or 2 ea. 2 x 6 or 2 ea. 3 x 4 top plates if supporting either floor members or roof trusses that are spaced more than 16" o.c. and do not bear within 511 of the supporting stud. Section 2517 (g) 2. Q Specify plywood grade and panel ~tifi<;ation index. Iable 25-N. Ra>Fs C..DX Yl.o{)Q. 0 ( its. When roof pitch is less than 3:12, design /idge as a beam. Section 2517 {h). li9. If foundation cripple wall studs are less than 14" framing shall be solid blocking. Section 2517 (g) 4. 1:il. Cripple wall studs exceeding 4 feet in ~ight shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. Q Show plywood sheathing over exposed eaves, Vother weather exposed areas, is exterior grade. Section 2516 (g) 3. c..ox: ,...-, ruc-r-e'(fi;?(c'.1c,e__ [..,,QIW E", u<..e CLx W\11\J 11.2. Show a weep screed at the foundation plate line on all exterior and stud walls to be stuccoed. Section 4706 (e). 1/3. Show corridor width to be minimum 36". Section 3305 (b). 131'. Specify truss layout for 30" x 30" attic adcess. Q Ridges, hips, and valleys shall be at 'idst one size larger than supported rafters. Section 2517 (h) 3. 'Sl-lfiV\l J lt:~ 1/6. In open beam construction, provide strap ties across the beams at the ridge support. Section 2501 (b). J. HECIANICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 1/1. Show the size, location and type of all heating and cooling appliances or systems. 1-Js. Show source of combustion air to furnace, per Chapter 6, UMC. J9, Every dwelling unit shall be provided with I heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC Sec. 1211. 10 2/13/86 1Jo. Show minimum 30" deep unobstructed working s~ace in front of furnace. Section 505, UMC . 1f1. Note on plans, clearances to be per manufacturer's listing. Section 504, UMC. if 2. Furnace shall not be installed under any stairway. Section 704 UMC. 1i/J. Furnace shall not be installed in any Jedroom, bathroom or in a closet or confined space with access only through such room, unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. 1'-4. Show I.C.B.O. approval number for prefab fireplace. l o/5. Show access to the attic or underfloor furnace to be minimum 30 inches by 30 inches. Section 708 & 709 UMC. lf6. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide. Section 708 UMC. i47. Show permanent electrical outlet and lighting fixture controlled by a switch for the attic furnace. Section 708 UMC. 1;8. Show details to comply with Section 709 f/or furnace under the floor, or Section 710 for ~oof or outside furnace. 9 Note on plan: Gas vents and noncombustible piping passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC Section 1706 (a) 6. 1:. KLl!CTRICAL (IIA'.IIONAL KLl!CTRICAL CDDE) All wiring shall comply with the National Electrical Code. 1io. Show on the plan the amperage of the e'iectrical service, the location of the service panel and the location of any sub-panels. 1/1. Show location of all electrical receptacles. Q Electrical recepta~le locations and/or ,, ¥cing is not adequate in 6eft!c~ -.(JIQ•,d 1,1 'rlol.l lor-.i-r AL SE/'.: ftrc> A"T1 D~ 2ET~\J 1::1:, ,,'l lJlJT Lf. 6 ,~ l'.Cr(lt'f'HI VlilLL LG:-l'rl2/:tfA..-P...,PT'-i \],'JI-.A) 1/3. Show at least one convenience outlet other than outlets for laundry, etc., outdoors, in garages and basements. Nee. Art. 210-52. Q Note convenience outlets in bathrooms, ~oors, and in garages and basements (other than for laundry and similar equipment) shall be GFI protected, NEC Art. 210-8. ALL ilLJi"'U:"'75 1js. Note electrical system ground to be provided per NEC, Art. 250-81. L. PLIMBIMG (UHIFORM PLIJ4BIMG <X>DE) 1i6. Show water heater size, type and location on plans. UPC, Section 1310. 157. Show source for providing combustion air I to fuel burning water heater. If wall opening in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one-half within the lower twelve inches. UPC, Section 1307. 11 2/13/86 1513. Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom. UPC Section 1309. 1~. Provide adequate barrier to protect water heater from vehicle damage. UPC Section 1310. Q Show T and P Valve on water heater and ~ route of discharge line to exterior. UPC, Section 1007 (e). ~ Provide dryer vent to outside. ~ Section 1903. ~ Note on the plan that hose bibbs and lawn ¥inkler systems shall have approved backflow prevention devices. UPC, Section 1003. 113. Shower stall shall acco111DOdate a 30" circle and have a minimum floor area of 1,024 sq. in. UPC 909 (d). M. ll>ISK IKSOLAl'IOR {DOPLXXES) 1!4. Show details of duplex co11111on (party) la11s and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of SO decibles and on Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibles_. Title 25. 1Js. Show how penetrations of assemblies for ~ping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 25. 11,6 . Provide insulation in walls and ceiling to achieve STC of 50 between garage and living area if garage use is not controlled by resident. Title 25. II. Ell!RCY OOMSJ!RVATION: PLEASE READ State regulations (California Admin. Code) require that the design satisy one of the attached alternative energy packages or submit calculations . The law also requires that many mandatory conservation items be satisfied. 1/1. Show on the Title Sheet of the plans, the required elements of the alternative energy package that was selected, and next to each element show how you are complying with each element. If calculations were used, provide similar data on the plans. Q The plan sheet showing the required ~~ts of the selected energy package, and listing the design elements showing compliance with that selected package, must be signed by either the owner or a licensed professional i.e., architect, engineer or contractor. A design professional must note his/her state license number. Section 1403 of Title 20. e Show on the plans the "R" value for the w;i1.ls, floors, ceiling and related areas. 9ACJLAk£ 1 K'En101fr-s e-3o c..E1ul\)6 -f'LAi-~ sr10w e.-19 Q Show double glazing as per Energy Design, ~lazing Schedule. riavl l.f-DolJe5 17f · Show on the plan how shading requirements are satisfied. l7f . The plans are not in compliance with the energy conservation compliance package selected or design calculations provided. Show on plans conformance as follows: 12 2/13/86 1/3. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Energy Conservation Requirements". W Show the size, type, make, model and \-o6tion of the space heating (or cooling) system and provide energy calculations if the output BTU/Hr. exceeds 45 1000 . O. CARLSBAD S.F.D. & DUPLEX SOPPLEJ1KR'I 1/s. Energy conservation design should be for Zone 7 See attached energy packages. 176. Floor drains 1DUSt have auto-prime ( city policy). Q Note exhaust fans cannot be ductless type 'fcity policy). 11f . New residential wtits must be pre-plumbed for future solar water heating. Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). l i 9. Note "two 3/411 copper pipes 11JUSt be i,hstalled to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). 1rji. All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy). 1eji. Incorporate the waterproofing details, on the attached Policy 80-8, where interior living space occurs below grade at the masonry wall(s). ~ Show on the Title Sheet on the plans, the ~rmation required by the attached Developmental Services Sheet 102683. 1rp. All new residential buildings, including additions, require a soils report. Please submit two copies. 1f4. Heavy timber framing, minimum 6" x 1011 beams and minimum 811 x 811 post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). V,5. Please see additional corrections, or remarks, on the following page. The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact &-«11 1./ fu'/ {qfL at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 1200 Elm Avenue, telephone 619/438-5525. Thank you. Enclosures: l. 2. 3. 13 2/13/86 CITY OF CARLSBAD Dates 5-S:-&k Prepared bys C,A Tl 'I fu1) &,EL □ Bldg, Dept. VALUATION AND PLAN CHECK FEE □ Esgil PLAN CHECK NO, ge,, -Cf4 ' ¼ -1ru, ~t; -lo I BUILDING ADDRESS _ __._l{wo~1i~C~O~t-:0~1~1.1~2----------------- APPLICANT/CONTACT -,'·m p &er?OH 1[;( BUILDING OCCUPANCY rz _;) / m-I . I TYPE OF CONSTRUCTION ✓ ~ ,J BUILDING PORTION BUILDING AREA 0i1fl.A1AJ (,, -r-tfr::-A Lit/ ,ru, flrcf::A l,t:I/Tfi J(' r,,:l-, - /.-,Ci/? a IA ~ 44oib 'JI ,A , DB:..J<.S ;..8_111 ){ '1- -rll·r,= B UIL Dfr,)t:c ,Yf'c 8 uv,f'Jlt., Ao~a .'8,:)g i1l )' ~e:. - (.', A f2. /;;(~i:;, ,Mo .1:1 '1( 1 4 - -m-r&r. Air Conditionin~ Commercial Residential Res. or Comm. Fire S-orinklers Total Value PHONE NO. 74B-'131-z._. DESIGNER PHONE -------CONTRACTOR PHONE ____ _ \ VALUATION VALUE MULTIPLIER ]/!), •1L)-n/l,J f2w~ ~Rnirr Pu r~ I ll~°l 7?-, IA/ (pr) /,,,/ 7 //l77-')t') 453,otJ I 2q4,4< I ' 1 rAt;2r,.,A ' t,1fd, I : 11111?4-4,L?, ,DI) i ~ q _~ I I I @ (c3 I @ Fee Adjusted To Reflect 0 Energy Regulations (Fee x 1.1) O Handicapped Regulations (Fee x 1.065) 8 uildin g Perm it Fee $-------------'---------"---------- plan Check Fee_~$ ____________________ _;$!:__ ______ _ C □ M MEN T 5,_: ------------------------------- 0/4/82 PLAN CHECK NUMBER $-lo/ ADDREESS _.2J"3~i (t {q f.:i_ ~ DATE ;;_ -;,, 6 -.176' µ.~ 5/3 PLANNING 'f~~'"c}~Ctt/ 0 Ul a:: -:::)-, -C"'". U, o•---+-- 0 w ~·-- :::) CJ 0:: SCHOOL FEES: SAN DIEGUITO ENCINITAS / X CARLSBAD SAN MARCOS SETBACKS: FRONT REAR /\--.,-....,,,----------.--------.;;__--~..-.....-- LANDSCAPE PLAN COMMENTS:_~...a-+~...;.i\(el') ___ , .... *~:t ..... $_-:.i:S,-Jv~~~-'-1 _ ___,,;,{1..._1..:..--+ l .;.;.//_,,.--___ _ ~ C-7&-;:, / ENVIRONMENTAL REQUIRED:_]~e¥f9'2...;;....i.\~..1.,;~=-,(~""'~-¥.e_:a&~e.:;_...,sill.,;0;..ii1>:;..:;ML,WA:-4-'~ .... ~~=-----....:V~\'_,_7 __ _ •1 ADDITIONAL COMMENTS :--..:1c::r.......;:..,M:.w:;~=-....:..:::;~O-~=~~~.:.:...~ ENGINEERING LEGAL DESCRIPTION VERIFIED? ~0/;Y APN CHECKED?~-------- p .F .F.: ~[~ PARK-IN-LIEU QUADRANT:__})~, FEE PER UNIT: ___ _ RIGHT-OF~WAY:_ --1/f~ TRAFFIC IMPACT FEE PER UNIT:_,+JY~/i~'A~---- EASEMENTS: 1'.LP ~ --al<-DRivEwAv: Zlwi.P. + ~ ~ ~- IMPRovEMENTs: f✓ ~ Cuoix)~ Ov/J ~ INITIALS:~ E.D.U.: £.(.,WO LATERAL:_lCW'O GRADING PERM;..;.I.....;T :~f......;;✓~-.,.--- GRADING COMPLETION CERTIFIED: -----·----------------- DRAINAGE: M-./)t\gslA[fy 1')½; k ADDITIONAL COMMENTS: ------------------------ OK TO ISSUE: __ ~--11--..J'--~.;_;,,,,;,~:=:-.---DATE: ~dih DPD2:DPD6:01/86 ~ n DEVELOPMENTAL SERVICES 1200 ELM AVENUE CARLSBAD, CA 92008-1989 LAND USE PLANNING OFFICE (619) 438-5591 <ttitp of <ttarlsbab NffiATIVE DECLARATION PROJECT ADDRESS/LOCATION: 2838 -2908 Unicornia Street, carlsbad, CA. PROJF.CT DESCRIPI'ION: 'l\velve apartments on three crljoining lots. N:> grading is required. The City of carlsbad has ronducted an environmental review of the above described project µirsuant to the Guidelines for Implementation of the California Environmental Quality Pct an:1 the Environmental Protection Ordinance of the City of carlsbad. 'As a result of said review, a Negative Declaration (declaration that the project will not have a significant impact on the environment) is hereby issued for the subject project. Justification for this action is on file in the Planning Department. A ropy of the Negative Declaration with supportive d::>curnents is on file in the Planning Department, City Hall, 1200 Elm Avenue, carlsbad, CA., 92008. Comnents from the public are invited. Please sul::mit corrments in writing to the Planning Department within ten ( 10) days of date of issuance. DATED: April 23 , 1986 CASE ID: EIA-977 APPLICANI': Ariana Inc. PUBLISH [)11.TE: April 23, 1986 ND4 11/85 ~1,~-~ MICHAEL J. ZM Planning Director , ' Applicant: FEE: $175.00 RECEIPT NO: ENVIRONMENTAL IMPACT ASSESSMENT FORM -Part I (To Be Completed by APPLICANT) A-.rz I A tJ A-J. tJ Cr CASE NO: _§tl_~..;..i....a1--------- DATE: Address of Applicant: i3oo8 Phone Number: ( fo 19 ) "'1 :! Ez -q '3 1 'k Name, address and phone number of person to be contacted (if other than Applicant) : ----'6=-· "'A.:.....:..t---1....:...::~=-------------------------- GENERAL INFORMATION: Description of Project': ___._l ... ~-_;;;.~~f?-~.;;..;..;.d_._,...,4""',t)...,e'""'vt......,.l-..___"""u~.Vv~1·..1.t;::;;;:s _ __..o:;;._14~--3""----- i vid.; 1.N'd L< a ( Lois • Project Location/Address: .ZB ?..8 -28 41-1: 9 02 -1-, Cf OB::, Ltkv l w 01,i t2 ::5'1 Lo. Co sf s... Assessor Parcel Number: !)_ l ~ -5 Co (9 -03~ {)cf, 0 s, 00 • Zone of Subject Property: _:Q~-~=--M-+------------------- Proposed Use of Site: 4 U..Vv\:t> O LA e.oe.,~ Lof c~,s-l SI b.,S11; List all other applicable applications related to this project: l 2. Describe the activity area, including distiguishing natural and man- made characteristics; also provide precise slope analysis when appropriate. 3. 4 .. s. lo~ ~ 1 (.,t.), t~ ~~id e ~ I 0 f'~ Describe energy conservation measures incorporated into the design and/or operation of the project. ~oul/4~12d 1 '\A..c::; • ~ ' ( ~ ~ ~ '°~ lvt'.AA' f I~ntial, include the number of units, schedule of unit sizes, range of sale prices or rents, and type of household size expected. l ~ ~ t5> I 7 SD -l 8so S:61/!f-t- f:l 'FPO,()o0 -{t ~ (O, 000 J~~ ~~~ If coraercial, indicate the type, whether neighborhood, city or regionally oriented, square footage of sales area, and loading facilities. 6. If industrial, indicate type, estimated employment per shift, and loading facilities. l)f\ 7. If institutional, indicate the major function, estimated employment per shift, estimated occupancy, loading facilities, and community benefits to be derived from the project. -2- I. ENVIRONMENTAL IMPACT ANALYSIS Answer the following questions by placing a check in the appropriate space. (Discuss all items checked "yes". Attach additional sheets as necessary.) 1) Could the project significantly change present land uses in the vicinity of the activity? 2) Could the activity affect the use of a recreational area, or area of important aesthetic value? 3) Could the activity affect the functioning of an established community or neighborhood? 4) Could the activity result in the displacement of community residents? 5) Could the activity increase the number of low and modest cost housing units in the city? 6) Could the activity decrease the number of low and modest cost housing units in the city? 7) Are any of the natural or man-made features in the activity area unique, that is, not found in other parts of the county, state or nation? 8) Could the activity significantly affect an historical or archaeological site or its settings? 9) Could the activity significantly affect the potential use, extraction, or conservation of a scarce natural resource? 10) Does the activity significantly affect the potential use, extraction, or conservation of a scarce natural resource? 11) Could the activity significantly affect fish, wildlife or plant life? 12) Are there any rare or endangered plant species in the activity area? 13) Could the activity change existing features of any of the city's lagoons, bays, or tidelands? 14) Could the activity change existing features of any of the city's beaches? 15) Could the activity result in the erosion or elimination of agricultural lands? 16) Could the··activity-serve-,ta·errCOtXcrge:-development -: · of presently undeveloped areas or intensify develop- ment of already developed-areas? -3- YES NO V I,/ t/ / ,/ ✓ \ / rl / 17) Will the activity require a variance from established environmental standards (air, water, noise, etc. ) ? 18) Will the activity require certification, authoriza- tion or issuance of a permit by any local, state or federal environmental control agency? 19) Will the activity require issuance of a variance or conditional use permit by the City? 20) Will the activity involve the application, use, or disposal of potentially hazardous materials? 21} Will the activity involve construction of facilities in a flood plain? 22} Will the activity involve construction of facilities in the area of an active fault? 23) Will the activity involve construction of facilities on a slope of 25 percent or greater? 24} Could the activity result in the generation of significant amounts of noise? 25) Could the activity result in the generation of significant amounts of dust? 26) Will the activity involve the burning of brush, trees, or other materials? 27) Could the activity result in a significant change in the quality of any portion of the region's air or water resources? (Should note surface, ground water, off-shore.) 28) Will the project substantially increase fuel consumption (electricity, oil, natural gas, etc.)? 29) Will there be a significant change to existing land form? (a) Indicate estimated grading to be done in cubic yards: -~:.e: ________ _ (b) Percentage of alteration to the present land form: .,..er--------~.,...,,...,,.. (c) Maximum height of cut or fill slopes: -~ 30) Will the activity result in substantial increases • in the use of utilities, sewers, drains or streets? 3·1) Is the :..activity carried ,out as. ,pact. of .a . lai:ger .. project-or series· of ·proj"ects?·: • YES NO / v / / I II. STATEMENT OF NON-SIGNIFICANT ENVIRONMENTAL EFFECTS If you have answered yes to one or more of the questions in Section I but you think the activity will have no significant environmental effects, indicate your reasons below: -{)ul'.Jl ~ ~ ~cf_&~ ~ ~~ ~-~t"J ;A,LJ~~ ~&9--d CUA-~ f?<i!...r ;~ be J.tl.. /AA.AA t.{... I III. COMMENTS OR ELABORATIONS TO ANY OF THE QUESTIONS IN SECTION I (If additional space is needed for answering any questions, attach additional sheets as needed.) Signature ____ ~---""--~~......,"""'""'"-~~~~c...z.-:';.....,,::'-r--'=-'--"'-...,,__,,,.... _________ _ Werso~~) Date Signed ___ ...._~ .... • -H-='--'---''-'-·.JL __ -_q~_ ..... (_9_~_G ________ _ -5- SAN MARCDS UNIFIED SOICOL DISTIUCT PROJEX:T SERVICE AVAIIABILI'IY LEITER (Applicant fil in -print legibly APPLICANT: Ariana-Gardality, Inc Address: 13008 Vista View Dr ONNER: same Address: u:x;. 00. _________ _ Phone No. Poway, CA ---=g-=2=-06~4------ Phone No. --------------------------- POOJECT DESCRIPI'ION ject located on Assessor's Parcel No. (s): ( Attach l egal description if necessary) nsus Tract No. _______ _ i=-=-=.::=-=..c.;.:;. ( check one or rrore) [J Minor Subdivision (TPM) 0 f.lajor Subdivision (TI!) Project Address/location Lot 515 Unicornio ~ss')r' s Parcel Nurrbers 1.1~~ 3.0JJCDJCD 2. LL.LI CII] CD 4 . DTI ITO CD Housing Type No. of D.U. 's No. of Bedrocms Single Family ~1u1tiple Family 4 units 8 bedrooms Mobilehane Units 1. o.vner/applicant agrees to reconfirm this pro.iect with the issuing school district every 6 rronths unless such action is not required by the district. District Phone_6;;...l-e9---'-74.;..4--'--'4'--7_76.;;._ ____ _ 2. o.vner/applicant understand that the certification for school service cont ained in t his Project Service Availability Letter i s no longer effective if the pr oject i s disapproved or if the con- ditional project approval (subdivision, permit, or other conditional use processes) expires. 3. The infonnation I have provided is correct. APPLICANf's SIGNATURE Date ----------------------------- SAN MARCDS UNIFIED SCHOOL DISTRICT CERTIFICATION OF SCHOOL AVAilABILI 'IY ffi J\Kl'i-AVAIIABILITI Date: ,o [O[!] DAY filTI] YR CTI TO: City of Carl sbad FROM: School District San Marcos Unified Grades Served :_K_-_1_2 __________ _ 1. D School services and facilities are ccmni tted for t his oroject . S<'r vicf's will be available concurrent with project need based on a s~ured agreement with the developer which has adeauate financing and clear intent. 'R~ertification of serv·ice availability is required prior to issuance of building permits. 2. ~ The undersigned school district hereby certifies t hat it will be abl e to provide adequate school services and facilities to the above descri bed pro,iect concurrentlj with tt he need of such project. o.vner /applicant has paid t he required develorx>r 's fee. q Unl S 3. □ The undersigned school district hereby certifies that it will not be able to provide adequate school services and facilities to t he above described project concurrently with t he need of such project because ______________________________ _ DISTRICT REPRESENl'ATIVF.' s SI GNATURE -'~.._,~""-#---=--"--"'-----Date ____ A...c.i;,_r_i_1_7_,_1_9_8_6 __ _ TITLE Facilities Technician Phone 744-4776 ------------- WHT'T'F.-c:IVTC ENI'I'I'Y VELl..OW-DISTRICT PINK-OVNER/APPLICANf To Speed Letter® City of Carlsbad -Building Department From SAN MARCOS COUNTY WATER DIS 1200 Elm St. 788 San Marcos Blvd. Carlsbad, Ca. 92008 Phone 744-0460 Area Code 619 subject _L_o_t_s _1s_1_a_c_o_s_t _a_M_e_a_d_o_w_s_u_n_1_· t_ll_3 ___________ S_a_n_M_a_rc_o_s.._, _C_a_l_if_o_rn_i_a___;..9...;;2;..,;0 .... 6 __ 9 ___ _ -No 9& IOFOLO MESSAGE To Whom It May Concern: Water Connection Fees have been purchased for (4) Four 5/8" meters on the above referenced property. If there are any questions please contact the undersigned. Date REPLY NO 9FOLD No IO►OlO ~ ---------~---.-- Date Signed ~ WilsonJones GRAYLINE FORM 44-902 3-PART < 1983 • PAINTED IN US A RECIPIENT-, LEUCADIA COUNTY WATER DISTRICT APPLICATION FOR SEWER SERVICE The application must be signed by the owner (or his representative) of the property to be served. The total charges must be paid to the District at the time the application is submitted. APPLICANT MUST SUBMIT EVIDENCE OF BUILDING PERMIT WITHIN 60 DAYS. FAILURE TO MAKE SUCH SUBMITTAL WILL RESULT IN AUTOMATIC CANCELLATION OF THE SE.WER PERMIT. THE SEWER CONNECTION FEE LESS A $50 ADMINISTRA- TIVE FEE WILL BE REFUNDED. A six-month construction period shall be provided and sewer service charges for the bal- ance of the fiscal year shall be collected at the time of application for sewer permits. Sewer service charges for subsequent fiscal years shall be collected on the tax roll in the same manner as property taxes. If the six-month construction period extends into the sub- sequent fiscal year, a prorated sewer service charge for that fiscal year shall be collected on the tax roll in the same manner as property taxes. The full sewer service charges for all subsequent years shall be collected on the tax roll in the same manner as property taxes. There will be no additional fee or refund if service actually commences on a different date. The prorated sewer service charge shall not be required in those applications for sewer permits for subdivisions. Such applicants shall be required to notify the District, on forms provided by the District, of escrow closings on individual properties within the subdivision. Sewer service charges shall commence upon close of escrow and will be the responsibility of the buyer. If a service late~al is required, it will be installed by the Leucadia County Water I , District. The service' lateral is that part of the sewer system that extends from the main collection line in the street (or easement) to the point in the street (at or near the applicant's property line) where the service lateral is connected to the applicant's buildtng sewer. The applicant is responsible for the construction, at the applicant's expense, of the sewer pipeline (building sewer) from the applicant's plumbing to the point in the street (or easement) where a connection is made to the service lateral. The connection of the applicant's building sewer to the service lateral shall be made by the applicant at his expense. The connection must be made in conformity with the District's specifications, rules and regulations; and IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLI~T. THE APPLICANT, OR HIS At:11'HORIZED REPRESENTATIVE MUST NOTIFY THE DISTRI~ AT THE "TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLECTION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND WILL NOT BE ACKNOWLEDGED The Inspection Deposit will be refunded upon the completion of satisfactory inspection of the connection to the District's sewer system. The inspection deposit shall not apply in thos, " cases in which the applicant has paid plan check and inspection fees for a subdivision. OWNER'S NAME: llriana-Garda]it.¥, Toe MAILING ADDRESS: 13008 Vista View Drive Poway, Ca 92064 PHONE NUMBER =~z..,.4 ..... 8---9 .... 3..,.J .. 2 _______ _ SERVICE ADDRESS: 2840 lloi carni a Street LOT NUMBER: 515 TRACT DES C R-=-I =pT=I=o-="N ..... : ....,_La---c,_o_s t.-a---nM.,.,ea,,..,dr::o.,..,w-=-s --,#,......,.3- ASS ESSO R'S PARCEL N0:~2~J5=--36=□=-~n3 ___ _ TYPE OF BUILDING_sf-D~_NO. OF UNTTS-4__ CONNECTION -FEE: LATERAL SIZE: ; EASEMENT: EXTRA FOOTAGE-: -@$__}Foot EXTRA DEPTH: @$ /Foot LATERAL FEE ---- I NS PECTION DEPOSIT PRORATED SEWER SERVICE FEE TOTAL PAID BY: CASH CHECK NO. 1542 RECEIVED BY: W.V. Roehl $6000.00 50.00 $ 6050. 00 The undersigned hereby agrees that the above infonnation given is correct and agrees to the conditions as stated. owner's s ~:ture 4-7-86 Date 17780-83 Account l