Loading...
HomeMy WebLinkAbout2718 UNICORNIO ST; ; CBR2019-2774; PermitBuilding Permit Finaled Residential Permit Print Date: 02/19/2021 Job Address: Permit Type: Parcel #: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 2718 UNICORNIO ST, CARLSBAD, CA 92009-5335 BLDG-Residential Work Class: 2153505400 Track#: $63,006.29 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Pool (City of Carlsbad Permit No: CBR2019-2774 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Closed -Finaled 10/03/2019 10/01/2020 TKers 02/19/2021 Description: HOUGHTON: DEMO EXISTING POOL AND REPLACE WITH 806 SF POOL & SPA// GAS AND ELECTRIC TO BBQ AND FIRE PIT// 84 SF RETAIN ING WALL (CITY STAN DARO) Property Owner: HOUGHTON MICHAEL AND DESIREE 350 SUMMIT TRAIL CT FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG ) CARLSBAD, CA 92010 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $1,230.82 Total Payments To Date: $1,230.82 Balance Due: AMOUNT $468.02 $327.61 $43.00 $80.00 $3.00 $8.19 $246.00 $55.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" offees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Ca rlsbad Municioal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which t he statute of limitation has previously otherwise expi red. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f \ www.carlsbadca.gov ( City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check Ctl1b20 l q_ ;;nLJ Est. Value PC Deposit --------- Date _.!='6'--_.3'---....1t./-1-J __ _ Job Address _~J~'-l~S~ .... \ J~N~\~O>~P..-rJ~\(_)_►~:i:: _____ Suite: ____ APN: 6)1's)'" 36'0 §:YOO CT /Project#: _________________ Lot#: ½ 71} Fire Sprinklers: yes I@ Air Conditioning: @I no Electrical Panel Upgrade: yes/~ BRIEFDESCRIPTIONOFWORK: DeHOL..11101-J Or <::)LO ft!)L AtvD £.e-B,Jtu wlTH: NE:4/ POOl-1 CQ\?>Q, l~L...)n.)D At->0 E1e.1: p,,-Pst:>R ~~tt::'t, cd.tlt:u_ □ Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: SF of affected area -----Is the area a conversion or change of use ? Yes/ No 00 Pool/Spa: c;?Ol.p SF Additional Gas or Electrical Features? £1 p.g: p rr: _A+)D ~ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ------------------------------------- □ Plumbing/Mechanical/Electrical Only: _________________________ _ D Other:------------------------------------- APPLICANT (PRIMARY CONTACT) Na me: M \ C,,'cl P. t: \ t:'OJ.f.o l:tTOiJ Address: s:rH'J ot-)1LO{q..)1n St City: C.P<'2.W>2>Af2 State: CA Zip: qd().)Cj Phone: :?tY -c)q~-7qa,3 Ema i I: J0 t\:O U. (q H'CQ,J@pt-,>A tleJ ~ • tJ 1,(,,- DESIGN PROFESSIONAL Name: C>C,,OTI bLO C:X-$. I '4M 0z~"P, 1,-..)(___ Address: L<l, (?;. CA'.f,...t~ >L City: SA,-} MM'.-uO~ State: c..A Zip: 93077? Phone: ?(aa---nl,,-"B3da Ema i I: OA.tJ a OC..0:D U..ODe'S\ 1,,t-l C, 12(,v p. CA2""1 Architect State License: __,S:...._7---=-.;)._vf--+-------- PROPERTY OWNER Name: ,-..,t \ C...Y-8 tZl.. P()UCatftO.J Address: ri/\, \J,-l lt.oB,,-Jt0 st:: City: (.M'LL..~ &AO State: CA Zip: 9;2009 Phone: 7 I ':1 -d9.?-7e, d 3 Ema i I: M tto \..l (,et\-TOtv@_, AfoJA i·t1=:n •. -1 • ,-.J €,- CONTRACTOR BUSINESS Name: ___________________ _ Address: __________________ _ City: ________ State:. ___ Zip: ______ _ Phone: ___________________ _ Email: ___________________ _ State License: ______ Bus. License:. ______ _ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov 8-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. □ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _ Policy No. _______________ Expiration Date: __________ _ □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: □AGENT DATE: ----------------------------------- ( OPTION B }: OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: --t-C---A..-"---P~f/4,_..p'._/e ______ □AGENT DATE: IO{ 0 3/oO('i CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ _ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANTSIGNATURE: lLc//4,.k DATE: lo./<2'l/,01q 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 Building Permit Inspection History Finaled (City of Carlsbad PERMIT INSPECTION HISTORY for (CBR2019-2774) Permit Type: BLDG-Residential Application Date: 10/03/2019 Owner: COOWNER HOUGHTON MICHAEL AND DESIREE Work Class: Pool Issue Date: 10/01/2020 Subdivision: LA COSTA MEADOWS #3 Status: Closed • Finaled Expiration Date: 07/20/2021 Address: 2718 UNICORNIO ST IVR Number: 22200 CARLSBAD, CA 92009-5335 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection Date Start Date Status 10/06/2020 10/06/2020 BLDG-SW-Pre-Con 140233-2020 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Oeficiency Pre con. Res(iming project after permit Yes shutdown. 10/26/2020 10/26/2020 BLDG-51 141963-2020 Passed Tim Kersch Complete Excav/Steel(Pools) Checklist Item COMMENTS Passed BLDG-Building Deficiency Note to pending stop work. Yes BLDG-52 Pool Plumbing 141962-2020 Passed Tim Kersch Complete 11/09/2020 11/09/2020 BLDG-21 143403-2020 Passed Tim Kersch Complete l,Jnderground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 12/18/2020 12/18/2020 BLDG-54 Equipotential 146594-2020 Passed Tim Kersch Complete Bond(Pools) 01/21/2021 01/21/2021 BLDG-53 148822-2021 Passed Tim Kersch Complete Elec/Conduit/Wiring(Po ols) BLDG-55 148821-2021 Passed Tim Kersch Complete Fence/Preplaster Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/19/2021 02/19/2021 BLDG-Final Inspection 150877-2021 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Bu ilding Defic;iency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Friday, February 19, 2021 Page 1 of 1 ✓. EsG1I A SAFEbu1lt Company DATE: 9-10-2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2019-2774.RC3 PROJECT ADDRESS: 2718 Unicornio St. SET: IV □ APPLICANT □ JURIS. PROJECT NAME: Houghton Residence-Retaining Wall Review Only [3J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to : [3J EsGil staff did not advise the applicant that the plan check has been completed . D EsGil staff did advise the applicant that the plan check has been completed. Person contacted : Date contacted: Telephone#: / (by: ) Email: Mail Telephone Fax In son 0 REMARKS: By: Erich A. Kuchar, P.E. Enclosures: EsGil 9-3-2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ,, ✓. EsG1I A SAFEbu1ll Company DATE: 7-20-2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2019-2774.RC1 PROJECT ADDRESS: 2718 Unicornio St. SET: III PROJECT NAME: Houghton Residence-Retaining Walls 0 APPLICANT 0 JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. C8'.I The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed . C8'.I EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Mark Leone Telephone#: 888-256-8440 Date contacted: (by: ) Email: Not Provided Mail Telephone Fax In Person C8'.I REMARKS: EsGil Reviewed Retaining Walls Only By: Erich A. Kuchar, P.E. Enclosures: EsGil 7-13-2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2019-2774.RC1 7-20-2020 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning , Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. The drawings due not state the maximum retained height for the retaining wall. Add to plan. This comment is still open as it has yet to be addressed. Also, there was no comment response letter answering all the comments and locations. Provide a complete response narrative as stated above. Make sure maximum retained height does not exceed city standard drawing that is referenced. The plans appear to be using city standard retaining wall details. A letter from Paul Welsh, P.E., L.S. is shown on sheet L5 saying the wall and foundations are in conformance with the San Diego Regional Standard Drawing Sheet C-01. This sheet does not appear in these plans. Add Standard drawings sheet C-01 to sheet L5 and remove standard drawing detail sheet C-06. This is why the retained heights of the walls needs to be on plan so correct details can be referenced. This comment is still open as it has yet to be addressed. 3. Note that per sheet C-01 the maximum height of the retaining wall is specifically governed by the max soil pressure. It is acceptable to use 1,500 psf as a max soil pressure without getting a Geotech investigation. That being said if the wall is retaining soil more then 3'-8" then verification of the max soil pressure must be Carlsbad CBR2019-2774.RC1 7-20-2020 submitted by a registered California Civil Engineer to use the 2,000 and 3,000 psf max soil bearing pressure details. If the soil max bearing pressure can not be determined over 1,500 psf but the wall needs to be over 3'-8" then complete structural drawings and calcs for wall design must be submitted by a California Civil Engineer stamped and signed. This comment is still open as it has yet to be addressed. MISCELLANEOUS 4. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 5. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D 6. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Erich A. Kuchar, P.E. at EsGil. Thank you. ✓. EsG1I A SAFEbuilfCompany DATE: 6-22-2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2019-2774 PROJECT ADDRESS: 2718 Unicornio St. SET: I PROJECT NAME: Houghton Residence-Retaining Walls □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. l:8J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person . D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. l:8J EsGil staff did advise the applicant that the plan check has been completed . Person contacted: Mark Leone Telephone#: 888-256-8440 Date contacted: (by: ) Email: Not Provided Mail Telephone Fax In Person [8J REMARKS: EsGil Reviewed Retaining Walls Only By: Erich A . Kuchar, P.E. Enclosures: EsGil 6-11 -2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, Cali fo rnia 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2019-2774 6-22-2020 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2019-2774 JURISDICTION: Carlsbad PROJECT ADDRESS: 2718 Unicornio St. FLOOR AREA: N / A REMARKS: N/A DATE PLANS RECEIVED BY JURISDICTION: 6-11-2020 DATE INITIAL PLAN REVIEW COMPLETED: 6 -22-2020 FOREWORD (PLEASE READ): STORIES: N /A HEIGHT: N/A DATE PLANS RECEIVED BY ESGIL CORPORATION: 6-11 -2020 PLAN REVIEWER: Erich A. Kuchar, P.E. This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation , noise attenuation and access for the disabled . This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification , modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2019-2774 6-22-2020 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. The drawings due not state the maximum retained height for the retaining wall. Add to plan. 3. The plans appear to be using city standard retaining wall details. A letter from Paul Welsh, P.E., L.S . is shown on sheet L5 saying the wall and foundations are in conformance with the San Diego Regional Standard Drawing Sheet C-01. His sheet does not appear in these plans. Add Standard drawings sheet C-01 to sheet L5 and remove standard drawing detail sheet C-06. This is why the retained heights of the walls needs to be on plan so correct details can be referenced. 4. Note that per sheet C-01 the maximum height of the retaining wall is specifically governed by the max soil pressure. It is acceptable to use 1,500 psf as a max soil pressure without getting a Geotech investigation. That being said if the wall is retaining soil more then 3'-8" then verification of the max soil pressure must be submitted by a registered California Civil Engineer to use the 2,000 and 3,000 psf max soil bearing pressure details. If the soil max bearing pressure can not be determined over 1,500 psf but the wall needs to be over 3'-8" then complete structural drawings and calcs for wall design must be submitted by a California Civil Engineer stamped and signed. MISCELLANEOUS 5. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Carlsbad CBR2019-2774 6-22-2020 6. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 7. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regard ing these plan review items, please contact Erich A. Kuchar, P.E. at EsGil. Thank you . Carlsbad CBR2019-2774 6-22-2020 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Erich A. Kuchar, P.E. BUILDING ADDRESS: 2718 Unicornio St. BUILDING OCCUPANCY: R-3 BUILDING AREA PORTION { Sq. Ft.) Retaining Wais 843 Air Conditioring Fire Sprinklers TOTAL VALUE Jurisdiction Code cb j 1997 UBC Building Permit Fee EJ lfH ~.S: J 1997 UBC Plan Check F,e 1r.1rn·. G Valuation Multiplier By Ordinance Type of Review: P Complete Review r Repetitive Fee ~ 17=.] Repeats ,, r Other r Hourty EsGilFee ,. Reg. Mod. 843 sft of retaining wall x $24.65 $/sft = $20,779.95 Value PLAN CHECK#.: CBR2019-2774 DATE: 6-22-2020 VALUE {$) r Structural Only 20,780 20,780 J , $137.901 ✓ Sheet 1 of 1 STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING RAINFALL. • 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN TH E FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. 7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY REGULATIONS. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. M \ G-~E::' L OWNER(S)/OWNER'S qJ.!!l!q DATE E-29 STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP CsB~Jq -:J~s BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Contr<ll Sediment Control BMPs Tracking Non-Storm Waier Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs I c:: c:: c:: 0 ..... ..... 0 0 :;:; c:: c:: -0 :;:; :;:; Ol C Q) -0 Q) en c:: E c:: -0 u u c:: c:: Ol E ..... C ::, ::, 0 'i:: .9-C c:: C E ..... .... .... :;:; '6 .... Q) C ::;; -0 en Ol .... Q) ..... ..... c:: '-::, >, Ol c:: Q) I.. c:: -~ c en en en C ·.: CT I.. C c:: ·Ol Cc a. Q) 'o.. .... -c:: en c:: > I.. w Q) c:: 0 Best Management Practice* ~ c:: 0 ca .... 0 Q) 0 I.. 0 Q) > :;:; en 3:: en ~ Q) C c:: Q) .... Q) C ..... en .s= Q) (/) c:: E a, Ol ca '6 c:: u .... u en -0 en i -0 "iji en ::;; c:: Q) c:: (BMP) Description ➔ u ·o en Ol Ol c:: c:: ~ ..... Q) Q) 2f Q) Q) C C 3:: c:: -ow c:: c:: 0 ::::, ::, I.. u ..... 0 I.. 0 "O >, 0 en C Q) ~ E :;:; C: 0 ca (/) ·-Ol 0 ,-Q)-........ u Q) C 0 Ol Q) ::;; 0 Ol 0 c:: Q) 0::: E 0 ..... N en ~ 0 c,,+i Q) 0 Q) 0 ·o.. .__ 3::: Q) X C Q) E ~ u Q) C: •-Ol 0.. 0 Q) .s= c:: Q) LL. E .::£ "iji ..... ::, .0 = en = 3:: 1....:;; c:: 0 :0 u·c I.. C ·.: .::£ I.. Ol ' ..... -0 u I.. > Q) ::, -0 .... ..... ·-Q) ·-"O Q) u -~ ~ C Q) I.. Q) u _...., -0 C +-'•-a. '6 .0 .... .0 C ·-C 0 0 .... C 1751 ..... Q) Q) C Q) u c:: 00 C Ol ..., 0 ..... .s= Q) ..... 0 ..... 0 =C:: ·-c:: Q) 0 CI.. Q) .s= .0 .... ~c 0 ...., .... en c:: .B 0 C .... 0 Q) _ c...., C .... a. 0 QC 0 3::: WO u5 (/) u ii: 0 en> (/) en o.. en o::: 3::: 0.. 0..0 0.. >U ::;; en ::;; en (/)(.) en ::;; CASQA Designation ➔ r---tO CJ) ~ I") v L() co r---tO 0 N I") r---tO ~ N I") v L() 'T ~ ~ 'T I I I I I I I I I I I I I I I I I I I I I u u u U 1 w w w w w w w w ~ ~ (/) en en en ::;; ::;; ::;; ::;; ::;; Construction Activity w w w w en en en en en (/) (/) (/) z z z z 3::: :;:: 3::: 3::: 3::: I )f Gradinq/Soil Disturbance I X X Trenching/Excavation X Stockoilinq Drillina /Borina Concrete/Asohalt Sawcuttina )( Concrete Flatwork :,( Paving X Conduit/Pipe Installation ,x X Stucco/Mortar Work ;,( Waste Disoosal Staging/Lay Down . Area Eauioment Maintenance and Fuelino Hazardous Substance Use/Storoqe Dewaterinq Site Access Across Dirt Other (list): Instructions: 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. • 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. PROJECT INFORMATION Site Address: /:J7 l'8 \Jg,.) l~t-J\.O £,T" Assessor's Parcel Number: ________ _ Emergency Contact: Nome: H le.,~ ~e: L t\O\l(o tttt?~ 24 Hour Phone: ']IL(,.. dq~-7qd3 Construction Threat to Storm Water Quality (Check Box) □ MEDIUM JZI" LOW Q) ..... en C :;:: ..., c:: en Q) ::, E 0 Q) ~ Ol c,C NC:: C C, :::r:: ::;; co I ::;; ;:: Q) ..... en 0-+-' 3::: C: Q) a, E ..... Q) ~ Ol uc c:: c:: 0 0 U:::!E co I i Page 1 of 1 REV 11/17 • J CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Developm r s , "' Planning Division 1635 Faraday Avenue (760) 602-4610 WWW c-.:irl<.h;inr.:i 110V DATE: 7 '17 '20 PROJECT NAME: PROJECT ID: APN: 2153505400 PLAN CHECK NO: CBR2019-2774 SET#: 3 ADDRESS: 2718 UNICORNIO ST This plan check review is complete and has been APPROVED by the PLANNING Division. By: SARAH CLUFF A Final Inspection by the PLANNING Division is required Yes No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the isst1ance of a building permit. Resubmitted plans should include corrections from all divisions. L : This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: MHOUGHTON@ANAHEIM.NET For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 7 Hector Salgado 760-602-4624 ~lQ! s ,1_rc1v <'<l.!ISb<1d1 :L.tQ.~ Gina Ruiz 76().602-4675 Gina Rut. , arlsb,1~,a gov ENGINEERING 760-602-2750 ----~------..--, I ... J Sarah Cluff 76()..602-4619 S.ir1h.CJut' cm1sl>a\1c J gQv -------- FIRE PREVENTION 760-602-4665 ------------ I _j I I _J 00 □ If Callforn,a Coastal Comm,ss,on Authonty Contact them at -7575 Metropolttan Drive Su,te 103 San Diego CA 92108-4402 (619) 767-2370 Determine status {Coastal Permit Required or Exempt) Habitat Management Plan Data Entry Completed? YES O NO 0 If property has Habitat Type 1dent1fied rn Table 11 of HMP complete HMP Permit application and assess fees rn Energov lncluslonary Housing Fee required: YES O NO [8J (Effective date of lnclus1onary Housing Ordinance -May 21 1993 ) Data Entry Completed? YES O NO 0 For construction of rnclus,onary un,ts ema,I not1f1cat1on provided to HNS? YES O NO 0 {Em ail Susan Steinkemp ,n HNS with proJect number and contact info) 0 O :=J Housing Tracking Form (form P-20) completed: YES O NO O N/A 12?] • t Site Plan: PLANCHECK 3: PLEASE DECLARE THE HEIGHT OF THE RETAINING WALL ~t L2 ~ ~rtaf ALONG THE SOUTHWEST PROPERTY LINE AS HEIGHT IS NOT DECLARED. 4'2.11 i2'.WR:nf~~ , -, ITEM 27 SHOWS THE PUBLIC RIGHT OF WAY WITHIN THE PRIVATE PROPERTY LINE . SU L:±_ PLEASE UPDATE WHERE THE FRONT PROPERTY LINE BEGINS AS PUBLIC RIGHl.JQF -- .I;"' , WAY CANNOT BE UPON PRIVATE PROPERTY. ml\id cttfYli{l,(~ t-.,.i f;;._~ 1" (,. THE FRONT YARD SETBACK IS DIMENSIONED AS BOTH 20' ANO OVER 29'6". see 1..2.. V· ,, PLEASE UPDATE SITE PLAN FOR CLARITY AND CONSISTENCY. Rt.1/tted -foG"h~w u· ft'Dnty"lrif ~ 1,~'' J ITEM 6 DECLARES A DRIVEWAY EXTENSION. PER THE FOLLOWING SECTION OF ~~ L.'2. " CODE, TABLE E, THE FRONT YARD SETBACK IS ONLY PERMITTED TO HAVE 30%f?l\'~ -k) ~ ~ 5 ~ DEDICATED TO DRIVEWAY: 21.44.060 Off-street parkang-Res,dentiaf zones .. SEE';:it,OW ('2-) )(.. THE FOLLOWING LANGUAGE: "In the required front yard on a paved driveway ore,ol"(,fttfl ~ \ <, },O _..e,. parking area that: 1. Does not exceed 30% of the required front yard area; or 2. Is r~n-; W/ -;, , ( f c-J comprised of 24 feet of width extended from the property line to th~ rear of the requir~nd ~(I.( pV '{ ~ ~ ' ,1&v--1 front yard, whichever is greater. -~e site pl4n oD"te • Aoo-t,c,tw~ 1,1,/p t.J_(\ J. TO ENSURE COMPLIANCE WITH THIS NO GREATER THAN 30% OF THE FRONT YARD St.4, L.2-:. ~ REQUIREMENT, PLEASE PROVIDE DIMENSIONS OF THE FULL FRONT YARD WITHIN .... (, ~f C 20' FROM THE FRONT PROPERTY LINE. PLEASE DECLARE:~ 4ddtA Sitt p\tU'l notti~I fD C f'Y'C. • 1. THE EXISTING DRIVEWAY SQUARE FOOTAGE AND DIMENSIONS E dfllJtWOJ.i:41~~ At.iJt.a diM • (4 12. THE EXISTING UNPAVED FRONT YARD SQUARE FOOTAGE ANO DIMENSIONS A<Ulta tot,r"lr.dd,.,, • 3. THE PROPOSED EXPANSION OF THE DRIVEWAY TO CONFIRM THE TOTAL OF EXISTING ANO PROPOSED DRIVEWAYS DOES NOT EXCEED 30% OF THE FRONT YARD. R'2'11Stc:ldrivewati. ~owmly pnposm1 t~) con:rett:stri~ .1,,.ee. sitt pft.1(1 notes • ( ITEM 12 DECLARES THE BBQ ISLAND AS REMOVED, PLEASE ADD A NOTE THAT IT IS "NOT A PART OF THIS PERMIT'' 5u ~na-1' l/r. ~t\J\seJ n&tt~lv -PLANCHECKS 1 & 2: TME HARDSGAPE PLAN Sr-i~T l2, IS NOT A SITE PLP,N PLEASE PROVIDE □□□ P-28 MORE INFORMATION TO SHOW COMPLIANCE WITH SETBACKS PER THE FOLLOWING HYPERLINK: Chapter 21 .10 R 1 ONE FAMILY RESIDENTIAL ZONE. PLEASE PROVIDE: . • 1. PROPERTY LINES S(t L.Q., Aadld ft, w1a-th or~ I• c.4nd lerqt'h of-\'?()'. · n. RIGHT-OF-WAY WIDTH ~Q, ~ .\0 '-0''ClJtbto f\... 3 DIMEll~SIONAL SETBAGKS 4-bG-T WIG~R ~-J;GU,.OwtNG-WYPERLINK "µ1 I 2<~~ L~~) • Provide a fully d1mens1onal site plan drawn to scale Show North arrow, property lines A-ddeJ 1b easements existing and proposed structures streets existing street improvements. nght-of-~ • _ -r---- Page 3 of 5 0711 l - way width, d1mens1onal setbacks and existing topographical Imes (including all Stde and rear yard slopes) Provide legal description of property and assessors parcel number City Council Policy 44 -Neighborhood Architectural Design Guidelines 1 Applicability YES O NO ~ 2 ProJect complies YES D N00 Zoning: /. 1 Setbacks SE+BACKS-MUST BE-SOOWN--TG ENSYRe-THAT THE ~-Gr 'NALLS IN THE FRO~H ¥.<i.RD DO NOT EXCEED 42" THAT TME HEIGHT'S OF WALLS $1.£; l,.1,, ~RT~~~~~~:~~ ::~~A~:~~~~~~~~◊:-i~=~~e::~ ~~=~ ~J~!f' ~GHT AS UNGER OR OV~-6-AND ~RE PROP€R--SeTBACKS ~ r.ME v~{,\U\laf !~~FORMATION BELOW ~I\ Clll~fflj Required~ Shown 20' & 29'6" PLEASE CLARIFY ~ Front· IF POOL EQUIPMENT IS UNDER 6' Interior Side Required _5 _ Shown §_ IF POOL EQUIPMENT IS-GV~ 00 □ oner S1ae Street Side Rear Top of slope Requ1roa 10% OF LOT '/tJIDTI-➔ Shown NOT SMOWN Required __ Shown _ Required _ Shown Required __ Shown __ 2 Accessory structure setbacks Front Interior Side Street Side Rear Structure separation 3 Lot Coverage Required __ Shown _ Required __ Shown __ Required __ Shown _ Required _ Shown Required __ Shown __ Required Shown 0 0 0 ' • 4 Height PLANCHECK 3 PLEASE DECLARE THE HEIGHT OF THE RETAINING WALL ALONG THE SOUTHWEST PROPERTY LINE AS HEIGHT IS NOT DECLARED. PLANCHECKS 1 & 2 MASGNR¥-ANO-GMY-WALLSAR€-SHOWN-WITH-,1,.1-H~S P~~NL~Y-OeG!ARE MAXIMUM-MEIGH-+S-TO--ENWRe PRGf:20SA.l OOES-NG-i:-E-XGEEO .,,.e-tGt4:rs REQWREQ I A'.J...!II BY CODE-, 5 € t, Vb \V 7" IN FRONT YARD SETBACK Required 42" MAX Shown 42 ~rfv~~~PMfovt-. IN SIDE/REAR YARD SETBACKS. Required 6' MAX Shown SW WALL HT NOT SHOWN ~I~~ lf"« 5. Parking Spaces Required Shown 4-1-'' ~~~ . (breakdown by uses for commercial and industnal pro1ects required) ~~~ Residential Guest Spaces Required Shown __ CJ,/. L.l.a.-A-&d&:f ~r,,t,oJ-& --t1) ? 1fl'2fftn 1,eh+tt1c1J tte~i1s. 0 0 0 ,. Additional Comments LIGHTING DESIGN SHEET L-6 ST ATES UP LIGHTING l s ~ n,te. PROPOSED. AS THE LIGHTING ITEMS AREN'T DETAILED, I SEE THAT THE TOP ANO -\1,at v,ll{lht MIDDLE PROPOSED FIXTURES ARE DOWN FACING OR SHIELDED, BUT THE BOTTOM dOt~ 'f--'J FIXTURE IS UPWARD FACING. PLEASE DECLARE WHERE THESE FIXTURES ARE NOTED ON SHEET L-6 AS THE LEGEND LABELLING ISN'T CLEAR WHICH LIGHT TYPE O ,sn}ft IS GOING WHERE. NOR WHERE THE UP LIGHTS ARE PROPOSED TO BE PLACED. f\tl~hl'.t}Y5 Page 4 of 5 07 1 I \J \eO.) P-28 PLEASE ENSURE THE UP LIGHTING DOES NOT CROSS OVER INTO NEIGHBORS' PROPERTIES OR PROVIDE AND DECLARE SHIELDING FROM NEIGHBORS VIEW FOR THOSE UP LIGHTS THAT MAY INTERFERE WITH NEIGHBORS. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE P-28 Page 5 of 5 07/11