Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 219; AS050182; Permit1/22/25, 10:16 AM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: AS050182 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS050182 2525 EL CAMINO Status: ISSUED REAL SPRINK Applied 9/12/2005 1563020900 Approved: 9/12/2005 0 Issued: 9/12/2005 Inspector: DANIEL'S JEWELERS, SUITE 219 FIRE SPRINKLER PLAN CHECK & INSPECTIONS Owner: BRADSHAW ENGINEERING CORP PLAZA CAMINO REAL 8645 ARGENT ST SANTEE CA 619-448-4300 about blank Fees($) 115 Add'I Fees ($) 0 C/O WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Total($) 115 Balance($) 0 1/1 Reliabld Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright -This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and I uniformly filled with water in the form of small drops or spray. Standard Pendent -This deflector configuration is normally used where the space above the piping is I limited or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice-By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as 40% more water or 65% less I water than the normal ½11 (15mm) orifice sprinkler. Conventional-This deflector configuration is used primarily in those countries where the LPG installation rules have precedence, The sprinkler is designed to distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra-high hazard installations. ,, Bulletin 110 Rev.S ModelG Automatic Sprinklers Spray Upright, Spray Pendent And Conventional Upright Pendent Small Orifice Upright Conventional Application and Installation Standard sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench, Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. ·Patent No. 4,440,234 The Reliable Automatic Sprinkler Co., Inc., 525 North MacOuesten Parkway, Mount Vernon, New Yark 10552 _.. ...I. 0 JJ (D < U) Technical Data "K" Factor Sprinkler Type us Standarcl-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position Y," (15 mm) Standard Orifice with Y," NPT (A½) Thread 5.62 Xe" (11 mm) Small Orifice with Y," NPT (R,½) Thread 4.24 ¾," (10 mm) Small Orifice with X" NPT (RX:) Thread 2.82 1{." (8 mm) Small Orifice with Y," NPT (RY,) Thread 1.98 '½," (20 mm) Large Orifice with Y,'' NPT (RX) Thread 7.96 '½," (20 mm) Large Orifice with¾" NPT (R¾)Thread 8.20 20 mm XHH with 20 mm Thread 8.20 1 O mm XLH with 1 O mm Thread 4.10 Conventional-Installed in Upriqht or Pendent Position 10mm XLH with 10mm Thread 4.10 15mm Standard Orifice with (RY,) Thread 5.62 20mm XHH with (R¾) Thread 8.20 Tern peratu re Rati nqs Maximum S~rlnkler Ambient ating Temperature FrameC1> Classlflcation "F ·c "F ·c Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue (1i Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes<1l Standard Finishes Bronze -All Temperature Ratings Chro'.11~ -All Temperature Ratings White l -All Temperature Ratings Only Frame and Deflector are Painted Soecial Application Finishes Metric 81.0 61.0 40.6 28.5 114.7 118,2 118.2 59.1 59.1 81.0 118.2 Sprinkler Identification Sprinkler Number (SIN} Height Approvals ssu SSP 2 7/tl 1• (73mm) 1,2,3,4,5,6, 7 R1025 R1015 2¾" (73mm) 1, 3, 7 R1023 R1013 2¾" (73 mm) 1, 2, 3, 7 R1021 R1011 2 °//JI /0 (73 mm) 1, 3, 7 R1022 R1012 2½" (73mm) 1, 2, 3, 7 R1026 R1016 2 ';i{e" (75 mm) 1, 2, 3, 7 R1027 R1017 75.4mm 4,5,6 R1027 R1017 73mm 4,5,6 R1024 R1014 73mm 5 R1074 73mm 4,5,6 R1075 75.4 mm 4,5 R1077 Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-Operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Approval Organizations 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corporation 3. Underwriters' Laboratories of Canada 4. Loss Prevention Council 5. Pleniere Assemblee Bright Brass Plated -Only frame, deflector and cap are plated. 135°F (57°C), 165°F 6. VdS Schadenverhutung 7, N.Y.C. BS&A No. 587-75-SA or N.Y.C. MEA 258-93-E (74°C), 212°F (100°C) Temp. Rating. Black Plated -Only frame, deflector and cap are plated. All Temp. Ratings. Polyester Coated l2l -Only frame and deflector are coated. Lead Plated -165°F (74°C), 212°F (100°C) and 286°F (141°C) Temp. Ratings. Wax-Coated (3l -165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. Wax-Coated Over Lead Plated (J) -165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. (1) Other colors and finishes are available. Consult factory for details. (2) UL listed and NYC MEA Approved only. (3) 212°F ( 100°C) brown wax may be used on 286°F ( 141 °C) sprinklers when maximum ambient temperatures do not exceed 150°F (66°C). UL Listed, FM Approved, NYC MEA 258-93-E. Ordering Information Specify 1. Model G 2. Deflector • Upright • Pendent • Conventional 3. Nominal Orifice 4. Inlet Thread 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manulactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualilied and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Relialll~ (800) 431-1588 Sales Offices (BOO) 848-6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/04 PIN 0099970005 Reliabld Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever ls released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright -This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and I uniformly filled with water in the form of small drops or spray. Standard Pendent -This deflector configuration is normally used where the space above the piping is I limited or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice-By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as 40% more water or 65% less I water than the normal½" (15mm) orifice sprinkler. Conventional-This deflector configuration is used pr'1marily in those countries where the LPC installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra-high hazard installations. Bulletin 110 Rev.S ModelG Automatic Sprinklers Spray Upright, Spray Pendent And Conventional Upright Pendent Small Orifice Upright Conventional Application and Installation Standard sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. *Patent No. 4,440,234 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 CD C f :f ..... -I. 0 :0 ;)! (I) . ' Technical Data "K" Factor Sprinkler Type us Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to I ndlcate Position ;I," (15 mm) Standard Orifice with Y," NPT (RY,) Thread 5.62 1/,,:' ( 11 mm) Small Orifice with };" NPT {R½) Thread 4.24 %" (10 mm) Small Orifice with,½'' NPT (RY,) Thread 2.82 1/,s" (8 mm) Small Orifice with Y," NPT (R,Y,) Thread 1.98 1:1,," (20 mm) Large Orifice with½" NPT (RX:) Thread 7.96 %" (20 mm) Large Orifice with ¾" NPT (R¾)Thread 8.20 20 mm XHH with 20 mm Thread 8.20 1 O mm XLH with 1 O mm Thread 4.10 Conventional-Installed in Uoriaht or Pendent Position 10mm XL..H with 10mm Thread 4.10 15mm Standard Orifice with (RY,) Thread 5.62 20mm XHH with (R¾) Thread 8.20 Temperature Ratinas Maximum S~rlnkler Ambient ating Temperature Frame<1> Classification "F ·c "F •c Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue Pl Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes(1) Standard Finishes Bronze -All Temperature Ratings Chro~~ -All Temperature Ratings White l -All Temperature Ratings Only Frame and Deflector are Painted SDecial ADolication Finishes Metric 81.0 61,0 40.6 28.5 114.7 118.2 118.2 59.1 59.1 81.0 118.2 Sprinkler Identification Sprinkler Number (SIN) Height Approvals ssu SSP 2 ¼" (73mm) 1,2,3,4,5,6, 7 R1025 R1015 2½" (73mm) 1, 3, 7 R1023 R1013 2½" (73mm) 1, 2, 3, 7 R1021 R1011 2 7h' le (73mm) 1,3, 7 R1022 R1012 2½" (73 mm) 1, 2, 3, 7 R1026 R1016 2 1%;' (75mm) 1, 2, 3, 7 R1027 R1017 75.4mm 4,5,6 R1027 R1017 73mm 4 5,6 R1024 R1014 73mm 5 R1074 73mm 4,5,6 R1075 75.4 mm 4, 5 R1077 Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted ( other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. I Approval Organizations 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corporation 3. Underwriters' Laboratories of Canada 4. Loss Prevention Council 5. Pleniere Assemblee Bright Brass Plated -Only frame, deflector and cap are plated. 135°F (57°C), 165°F 6. VdS Schadenverhutung 7. N.Y.C. BS&A No. 587-75-SA or N.Y,C. MEA 258-93-E (74°C), 212°F (100°C) Temp. Rating. Black Plated -Only frame, deflector and cap are plated. All Temp. Rattngs. Polyester Coated <21 -On!y frame and deflector are coated. Lead Plated -16S"F (74°C), 212°F (100°C) and 286°F (141°C) Temp. Ratings. Wax-Coated l3) -165°F ( 7 4 °C) Clear Wax, 212°F ( 100°C) Brown Wax. Wax-Coated Over Lead Plated <3l -165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. t1) Other colors and finishes are available, Consult factory for details. (2) UL listed and NYC MEA Approved only. 13) 212°F (100°C) brown wax may be used on 286°F (141°C) sprinklers when maximum ambient temperatures do not exceed 150°F (66°C). UL Listed, FM Approved, NYC MEA 258-93-E Ordering Information Specify 1. Model G 2. Deflector • Upright • Pendent • Conventional 3. Nominal Orifice 4. Inlet Thread 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Assoc1ation, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Reliable (BOO) 43H588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Oftices Revision lines indicate upda1ed or new data. www.,eliab1espr,nkleccom Internet Address EG P,n!ed in U.SA 11,!)4 P/N 999997(XXJ5